Vous êtes sur la page 1sur 2

®

Luwa Fine Dust Filter FP

The superior solution


● Comprehensive range – ● Glass fibre paper – no fibre ● Direction of air flow and
independently tested loss installation can be chosen
either way round
● Low pressure drop – ● Self-supporting rigid struc-
maximum economy ture – high bursting ● Without pollutant emission
pressures, dust migration fully incinerable – recyclable
● Large filter surface of 18 m2
impossible materials
– extremely long service life
– nominal air flow up to ● Frame manufactured from
5000 m3/h recycled plastic
Luwa Fine Dust Filter FP – the superior solution

Technical Data
Luwa Fine Dust Filter FP- 65-610 75-610 85-610 95-610 98-610
Air flow (normal service life) m3/h 5000 5000 5000 5000 4250
Initial pressure drop Pa 140 140 145 160 190
Rated air flow (long service life) m3/h 4250 4250 4250 4250 3400
Initial pressure drop Pa 100 100 105 120 140
Filter class as per EN 779 – F6 F6 F7 F8 F9
Filter class as per EUROVENT 4/5, DIN 24185 – EU 6 EU 6 EU7 EU8 EU9
Efficiency (atmospheric) average3), EN 779 % 70 70 82 93 98
Arrestance (gravimetric) average3), EN 779 %  95  98  99  99 100

250
Initial pressure drop [Pa] ➞

200

150

H
100

70

50 25
40 HT: 292 592
NT: 300
Type: 30
FP–..–610 2000 3000 4000 5000
Types, Dimensions
FP–..–508 2000 3000 4000
FP-.. -305 -420 -508 -610
FP–..–305 1000 1500 2000 2500
Dim. H 287 402 490 592
Nominal air flow [m3/h] ➞ Weight kg 2.8 3.7 4.3 5.1

Luwa FP Fine Dust Filters remove air Pressure drop: Frame «HT»:
contamination such as fine dust, – recommended final pressure drop: Plastic and galvanized steel
smoke, vapor, soot, pollen, bacteria, 450 Pa Sealent:
etc. and are therefore ideally suitable as – max. final pressure drop (endurance Polyurethane
final filters or as prefilters for HEPA- or strength): 800 Pa Flammability class. of materials used:
ULPA-filters in air conditioning installa- – bursting pressure (new filter): – Model «NT»:
tions.  1500 Pa K2/F2 according DIN 53438
They are suitable for all standard filter Admissible relative humidity: – Model «HT»:
applications, especially with those – FP-65: 85 % K1/F1 according DIN 53438
requiring increased Service Life, Safety – FP-75/85/95/98: 100 %
and Versatility. Luwa FP Filters are Remarks
available in 6 efficiencies1), 4 nominal Materials 1) Luwa Ultrafilter FP, refer to leaflet
sizes, 2 depths2) and 2 models (NT/HT). Filter medium: 42.12.01
– FP-65: 18 m2 cellulose fibre paper, 2) Luwa Fine Dust Filter FP-P, refer to

– FP-75: 16 m2 glass fibre paper, leaflet 42.13.01


– FP-85/95/98: 18 m2 glass fibre paper, 3) Measurements acc. to ASHRAE

Application parameters zigzag folded to form mats 52.1 and EUROVENT 4/5.
Continuous operating temperature: Frame «NT»: Official test reports upon request.
– Model «NT»: 75 ºC 4) Incinerable halogenefree recycled 4) Temperatures over this limit are to be

– Model «HT»: 120 ºC Polystyrol avoided.