Model: P750E6

Generator Specification
Performance Data
Service PRP (1) ESP (2)
Model P750E6
Power (kVA) 688 750
Engine brand Perkins
Power (kW) 550 600
Engine model 2806A-E18TAG3
Rated speed ( r.p.m) 1800
Speed control type ECM
Standard voltage (V) 220/127V, 440/254V
Phase 3
Rated at power factor(cos phi) 0.8
Control system Digital
Star ter motor voltage 24V
AU VE
RI
BURE

ISO 9001
TA S

BUREAU VERITAS
Certification
182 8
Frequency 60HZ
Engine speed (RPM) 1800
AGG Power gensets are compliant with ISO 9001 and CE standard, which include the
following directives: 100% standby power 141
·2006/42/EC Machinery safety. Fuel 127
100% prime power
·2006/95/EC Low voltage Consumption
·EN 60204-1: 2006+A1: 2009, EN ISO 12100: 2010, EN ISO 13849-1: 2008, EN 75% prime power 95
12601 : 2010 (L/H)
50% prime power 66
(1) PRP (Prime Power):
According to ISO8528-1, prime power is the maximum power available during a variable
Standard reference Conditions
power sequence, which may be run for an unlimited number of hours per year, between
Note: Standard reference condition 25℃ (77℉) air inlet temp, 100m(328ft) A.S.L 30%
stated maintenance intervals. The permissible average power output during at 24 hours
relative humidity. Fuel consumption dat with diesel fuel with specific gravity of 0.85 and
period shall not exceed 80% of the prime power. 10% overload available for governing
conforming to BS 2869: 1998, Class A2
purposes only.

(2) ESP (Standby Power):


L L
According to ISO 8528-1, It is defined as the maximum power available, under the
agreed operating conditions, for which the generating set is capable of delivering for up
to 500 hours of operation per year (of which no more than 300 hours for continuative
H H
use) with the maintenance intervals and procedures being carried out as prescribed by
W W
the manufacturers. No overload capability is available.

Powers ESP PRP Standby Dimension and Weight


Voltage (V) KVA KW KVA KW Amps Dimension Open Silent

480/277 750 600 688 550 902.1 Length (L) 3340mm 4750mm

688 Width (W) 1540mm 1900mm


440/254 750 600 550 984.1
Height (H) 2125mm 2530mm
380/220 750 600 688 550 1139.5
Net Weight 4470 5900
220/127 750 600 688 550 1968.3
Fuel Tank (L) 820 1050
208/120 750 600 688 550 2081.9 Note: This parameters allows for some acceptable deviations.

www.aggpower.co.uk
Engine Specification: 2806A-E18TAG3

Basic technical data Induction system

No. of cylinders 6 Clean filter 3.7kpa

Cylinder arrangement Ver tical in-line Dir ty filter 6.4kpa

Cycle 4 stroke Air filter type Paper element 457 mm diameter

Induction system Turbocharged

Compression ratio 14.5:1

Bore 145mm

Stroke 183mm Lubrication system


Cubic capacity 18.1L 62L
Total lub capacity
Air temperature 25℃ 45L
Sump minimum
Barometric pressure 100 kPa Sump maximum 53L

Lubricating oil pressure

at rated speed 420kPa

Cooling system Sump drain plug tapping size 1 in NTPF

Total coolant capacity 61L Lubricating oil pressure

Radiator fins per inch 15 -Relief valve opens 610 kPa

Method of drive Gear Oil filter spacing 30 microns


Maximum top tank temp 103℃ Oil consumption as a

Thermostat operation range 88-98℃ percentage of full load fuel


0.1%
Radiator face area 1.75 ㎡
Rows and material 2 Aluminum
Pressure cap setting 70 kPa Electrical system

Fan diameter Type Insulated return


965 mm
Drive ratio Alternator voltage 24 volts
0.8: 1
Number of blades Alternator output 70 amps
9
Number of teeth on flywheel 136

Star ter motor power 9 kW

Fuel system

Injection system MEUI

Fuel injector pressure 200 MPa General installation Prime power

Combustion air flow 42.3 m³/min


Fuel lift pump delivery pressure 600 kPA
Exhaust gas temp 487.8℃
Fuel lift pump maximum suction head 3m
Exhaust gas flow, wet 100 m³/min
Fuel lift pump maximum pressure head 4m
Engine coolant flow 6.1 I/min
Fuel filtration level primary 10microns
Cooling fan air flow 702 m³/min
Fuel filtration level secondary 2microns

Fuel lift pump output per hour

at 1500/1800 rev/min 413/457litres/hour

www.aggpower.co.uk
Alternator Specification
Emergency voltage curve

Sudden increase warp


Alternator Sudden voltage warp Sudden decrease warp
520
Number of phase 3

Power factor (Cos Phi) 0.8 464

+1%
Poles 4 408 +1%
380
380
-1%
Winding Connections (standard) Star-serie 352

Terminals 12 296

Insulation type H class 240


0 1 2 3 4 5 6 7 8 9 10 11 12
δu%: -18.18 1.95s
Winding Pitch 2/3 δu%: 8.89
Benchmark phase: A
Benchmark phase: A
Min. voltage: 310.9V Recovery time:
Recovery time: 0..12ss
Max. voltage: 413.8V

IP rating IP23

Excitation system Self-excited

Bearing Single bearing Emergency frequency curve


Coating Vacuum impregnation Sudden increase warp
Sudden voltage warp Sudden decrease warp
70
Voltage regulator A.V.R

Couping Flexible disc 62

54 +1%
50
-1%
+1%
50
-1%
46

38

30
0 1 2 3 4 5 6 7 8 9 10 11 12
δf%%: -10.64 Benchmark phase: A Min. frequency: 44.68Hz Recovery time: 1..95s
Three phase Reliable Single phase
δf%%: 7.74 Benchmark phase: A Max. frequency: 53.87Hz Recovery time: 0..54s

Options

Engine Alternator Generator Sets Fuel System

· Water Jacket · Winding Temp measuring · Tools with the machine · Low fuel level alarm
Pre-heater Instrument · Extended range fuel tank · Automatic fuel
· Fuel heater · Alternator Pre-heater · Bunded fuel tank feeding system
· PMG · Fuel T-valves
· Anti-damp and anti-corrosion
treatment
· Anti-condensation heater
· Winding and bearing RTD

Canopy Lub oil system Cooling System Control Panel

· Rental type · Oil Pre-heater · Front heat protection · Remote control panel
Canopy · Oil temp sensor · ATS
· Trailer · Synchronizing controller
· Adjustable ear th leakage
relay

www.aggpower.co.uk
Control Panel

Configuration Benefits

· Emergency stop button · Less wiring and components


· Integrated solution
· Protection MCB
· Less engineering and programming
· Battery charger · User friendly set-up and button layout
· Integrated aviation plug · Module can be configured to suit individual applications
· ATS connection · PC software for simplified configuration
· Digital control module · Wide range of communication capabilities

Operation conditions
Features
· Operation temp: -20 ˚C to + 70 ˚C
· Storage temp: -30 ˚C to + 80 ˚C
· Operating humidity: 95% w/o condensation
· Vibration: 5-25Hz, ±1.6 mm
5-1 00 Hz, a= 4g
· Shocks: a= 500m/s²

Options

· Ethernet interface (Remote monitoring and control)


· GSM modem/wireless internet (Remote monitoring and control)
· RS232-RS485 Dual por t interface
· Synchronizing control panel
· Distribution board with sockets kit and power busbar
· Battery trickle charge ammeter
· Ear th leakage protection
· Ear th fault protection
· Low fuel level alarm
· Low fuel level shutdown
· High fuel level alarm
· Fuel transfer system control
· Low coolant level shutdown
· High lube oil temp shutdown
· Overload via alarm switch on breaker
· Engine coolant heater controls
· Control panel heater
· S peed adjust switch
· Oil temp displayed on LCD screen
· Additional 8 inputs and outputs
Publication No. GYH0518N, ISSUE 1 @ AGG UK

AGG UK | AGG China | AGG USA | AGG UAE Distributed by

info@aggpower.co.uk | www.aggpower.co.uk

Follow us @facebook.com/aggpowergroup

Follow us @linkedin.com/company/agg-power

Follow us @ AGGPOWER

All information in the document is substantially correct a the time of printing


but may be subsequently altered by the company.

Vous aimerez peut-être aussi