Vous êtes sur la page 1sur 54

JB

i
X T
~
fann
Fann Instrument Company
afc
INDEX

Aging Cells, High Temperature 35 Filter Presses, Miniature 24 pH Meter, Lab Model Digital 20
Aging Cells, Pressurized 35 Filter Presses, Multiple Unit 23 pH Meter, Pocket 20
Alkalinity Test Kit 38 Filter Presses (FANN), Portable 25 PHPAKit 37
Amine Detection Kit 47 Filter Presses (FANN), High Temp 28 Pressuring Assemblies, CO2 24
Aniline Number, Flash Point and Filtrate Analysis Kits 38 Reagents 53
Fire Point Test Kit (FANN) 45 Funnel Viscometer, Marsh 5 Residual Oil Filtration Kit 43
Aniline Point Determination Kit 45 Galvanic Corrosion Monitor 43 Resistivity Meter 19
Analysis Kits, Chemical 38 Garrett Gas Train 46 Resistivity Meter (FANN) 19
Balances, Prescription 50 Glassware 51 Retorts 33
Bridging Materials Tester 30 Hardness Titration Kit 39 Rheometer Calibration Stand 7
Brine Test Kit 36 Hot Plate 50 Rheometer Calibration Test Kit 7
Brine Crystallization Kit 37 Hydrogen Sulfide Detection Kit 46 Rheometer Cups, Heated 6
Brushes 51 Hydrometers 36 Rheometer, Hand-Operated 6
Calcimeters 34 Hydrometer Kit 36 Rheometer, Repair Manual 7
Calibration Fluids 11 Hygrometer Kit 18 Rheometer, Variable Speed 6
Calibration Kits, Viscometers 11 Iron Content Kit 37 Rheometer (FANN), Recording 12
Calibration Stand, Rheometer 7 Iron Titration Kit 47 Rheometer (FANN), High Temp.
Capillary Suction Time Instrument 43 Lab Mixing Tank 49 Recording 15
Capillary Viscometer 7 Lost Circulation Test Cell 30 Roller Ovens 34
Centrifuges 50 Magnetic Stirrers 50 Sand Content Kit 18
Chemical Analysis Kits 38 Membrane Filter Tester 43 Scale Deposition Test Cell 46
Chloride and Alkalinity Test Kits 38 Methylene Blue Adsorption Kit 39 Scale Solubility Test Kit 47
Consistometer (FANN) 13 Ministill (FANN) 32 Shearometer 5
Corrosion Coupons and Holders 44 Mixers (FANN) 48 Spatulas 52
Corrosion Test Cell 35 Mixers, High Shear 49 Special Purpose Test Kits 47
Cups, Measuring 51 Mixers, High Speed 48 Sticking Tester 30
Deaerator, Mud 4 Mud Balance 4 Stop Watches and Timers 5
Differential Sticking Tester 29 Mud Balance, Pocket Size 4 Sulfide Ion Test Kit 47
Drill Pipe Corrosion Coupons 44 Mud Deaerator 4 Testing Equipment 51
Dynamic Filtration System 29 Mud Retort (FANN) 33 Testing Handbook 51
Electrical Stability Tester 32 Mud Test Kit, Airplane 41 Thermometers 53
Emulsion Test Cell 19 Mud Test Kit, Offshore 41 Viscometer, Capillary 7
Emulsion Stability Tester (FANN) 32 Mud Testing Chemicals 53 Viscometer (FANN), Hand-Operated 9
EP and Lubricity Tester 32 Multi-Retort 33 Viscometer (FANN), Electric 8,9
Filter Paper 51 Nitrate Ion Concentration Viscometer, 70HTHP (FANN) 14
Filter Press, Hydraulic 22 Test Kit (FANN) 45 Viscometer (FANN), Accessories 9,10,11
Filter Press, Low Pressure 25 Offshore Pilot Testing Kit 40 Viscometer, (50C) (FANN) Accessories..16,17
Filter Press, Parts and Oil and Water Retort Kits 32 Water Analysis Kit 39
Accessories 24 Oil Mud Test Kit 40 Water Hardness Test Kits 39
Filter Presses, High Pressure, High Particle Size Plate Kit 18 Wet Screen Analysis Kit 18
Temperature 26 Permeability Plugging Apparatus 28 Zinc Carbonate Test Kit (FANN) 47
Filter Presses, HPHT, Parts and pH Indicators 21
Accessories 26,27 pH Meters, Digital 20

Copyright® 1992. Baroid Drilling Fluids, Inc. 7.5M-GP-3/92 Printed in United State»
14000—BAROID MUD BALANCE 14300—BAROID MUD DEAERATOR
The Baroid Mud Balance provides a simple method for the The Baroid Mud Deaerator aids in getting accurate drilling
accurate determination of mud density. An outstanding fluid density measurements by removing air and other
advantage of this balance is the fact that the temperature gases from the fluid sample.
of the drilling mud does not materially affect the accuracy A stainless steel paddle agitates the sample while a
of readings. The durable construction of the Baroid Mud hand-operated vacuum pump draws off the excess air and
Balance makes it ideal for field use. Despite its sensitivity, gas. This tool is extremely useful in gas-cut situations.
it contains no easily breakable parts.
Principally, the balance consists of a base and gradu- 14300—Baroid Mud Deaerator
ated arm with cup, lid, knife edge, rider, built-in spirit level,
and counter-weight. The constant volume cup is affixed to
one end of the graduate arm and the counter-weight on
the opposite end.
A plastic carrying case is provided that holds the bal-
ance intact and in working position.
No. 14300—
Manufactured under design patent No. 186,243. Mud Deaerator

Complete Unit
14000—Baroid Mud Balance, 4 scale, complete in plastic case. Gradu-
ated in Ib/gal (6-24), Ib/sq in/1000 ft of depth (310-1250), Ib/cu. ft.
(45-180), and specific gravity (.72-2.88)
14001—Baroid Mud Balance No. 140, without case

Parts for Baroid Mud Balances


12400—Lid for Cup for No. 14000 Mud Balance
12403—Lead Shot, Vial
13300—Plastic Carrying Case for No. 14000 Mud Balance, Old Style
13400—Plastic Carrying Case, New Style, includes fulcrum
14016—Knife edge and Level for No. 14000 Mud Balance
14030—Base for No. 14000 Mud Balance, complete with fulcrum

14200—POCKET SIZE MUD BALANCE


For engineers requiring maximum portability and small
size, the Baroid pocket size mud balance is recom-
mended. The scale reads from 5.8 to 17 Ib/gal and can be
extended to 15.8 to 27 Ib/gal by use of weight extension
furnished in base of balance. The balance is made of
plastic for corrosion protection and long life. Numbers
and other markings stay sharp and easy to read even with
rough use.

14200—Pocket Size Mud Balance

No. 14000-Mud Balance

No. 14200—Pocket Size Mud Balance


20100—PLASTIC MARSH FUNNEL BAROID STOPWATCHES AND TIMERS
VISCOMETER The Baroid Stopwatch is recommended for use with the
The Baroid Marsh Funnel Viscometer is made of rugged, Marsh Funnel. It has a 60-second dial with 1/5-second
break-resistant plastic that resists temperature change division and a 30-minute register. Start, stop, and fly-back
deformation. Volumetric accuracy is assured. Plastic are operated by pressure on the stem.
provides insulation for user's hands. A metal orifice
20700—Baroid Stopwatch
assures accurate readings. The Marsh Funnel is used for 20703—Stopwatch, Digital Electronic
routine viscosity determinations on almost every drilling N7700—Timer, interval, 30-minute
rig. N7800—Timer, interval, spring wound, any interval from 15 sec to 2
hours
20100—Marsh Funnel Viscometer, yellow break-resistant plastic

BAROID MEASURING CUPS


The 1,000-cc high-impact plastic measuring cup, gradu-
ated in cubic centimeters and fluid ounces, is designed
specifically for use with Marsh Funnel Viscometer mea-
surements and with the Baroid Clip-Type Mud Mixer. Lines
are molded in at 350 ml and at one quart (32 fl oz) to aid in
these tests.
Stainless Steel Measuring Cups, graduated in cubic
centimeters and fluid ounces, are available where other No. 20700—Stopwatch
measurements are needed.

20200—Measuring Cup, 1000-cc, high-impact plastic


20211—Measuring Cup, 500-cc, stainless steel
20212—Measuring Cup, 1000-cc, stainless steel
20213—Measuring Cup, 2000-cc, stainless steel 24000—BAROID SHEAROMETER SET
The Shearometer is used for determining the gel-
strengths of drilling muds. The results are read directly
from a calibrated scale and give gel-strength in pounds of
shear per 100 square feet of area. A special Shearometer
Tube, No. 24205, is available for tests on aged mud.

Shearometer and Accessories


24000—Baroid Shearometer Set, complete with two No. 24200 Shearo-
meter Tubes, 5-gram
No. 20100— 24200—Shearometer Tube, aluminum, 5-gram
Marsh Funnel 24206—Calibration Chart for the 5-gram Shearometer
Viscometer 24205—Shear Tube, stainless steel, with weight support, 20-gram. For
testing drilling mud after aging at high temperature.
25500—Weights

No. 20211—
Stainless Steel
No. 20200— Measuring Cup
Plastic
Measuring Cup

No. 2400—Shearometer Set


28600—BAROID VARIABLE-SPEED 28000—BAROID RHEOMETER
ELECTRONIC RHEOMETER The Baroid Rheometer is a precision-built, multiple-speed
The Baroid Variable-Speed Electronic Rheometer is a rotational viscometer designed specifically for field
precision rotational viscometer built for convenient field testing the Theological properties of drilling fluids. The
testing of the Theological properties of drilling fluids. Baroid Rheometer is operated at two rotational shear
Speeds can be selected in one of two modes. The vari- rates, and the readings obtained are used to determine
able mode allows continuous speeds from 3 to 600 rpm, the plastic viscosity and yield point of the drilling fluid
while the second mode offers settings at conventionally being tested.
used speeds of 100,200, 300,600 rpm and gel strength (3 The Baroid Rheometer is hand-powered by turning a
rpm). Closed loop speed control allows accurate testing of small crank that drives a rotor at a preselected constant
shear thinning fluids, because the speed remains locked speed through a precision gear train governor. Rotor
in to the desired speed throughout testing. The rpm speeds of either 300 or 600 rpm are obtained by setting
readout resolution is 1 rpm on a digital display; the indi- the position of the speed control lever. A third position of
cator dial is read through a cover-mounted magnifier and the speed control lever is available for operating the rotor
uses a conventional torsion spring. at a higher speed for stirring the drilling fluid sample.
The unit can be powered by a 12-volt DC circuit or 115 Gel-strength measurements are read directly from the
or 230 volts AC, 50-60 Hz. Normal drilling rig-voltage and deflection scale. When making gel-strength measure-
frequency variations do not affect the rheometer. ments, force is applied manually by turning the gel knob
A cantilever frame supports this instrument and allows and observing the maximum reading on the deflection
tilting for sample cup cleaning and changes. The plastic scale before the gel breaks.
viscosity and yield point of the fluid being tested can be The Baroid Rheometer is supported on a counter-
obtained by plotting a graph. balanced telescoping frame that provides easy adjust-
The rheometer, complete with cup and cables, weighs ment of the rotor depth of the drilling fluid sample. No
less than 12 pounds. electrical power of any kind is used for operation. No field
maintenance is required. It is the lightest field instrument
28600—Baroid Variable-Speed Electronic Rheometer with Case available for determining plastic viscosity and yield point.
28680—Carrying Case, Attache Type
28000—Baroid Rheometer, hand-operated
28055—Cup for Baroid Rheometer
28080—Carrying Case, Attache Type

No. 28600—Variable-Speed
Electronic Rheometer

No. 28000—Rheometer

25120—HEATED RHEOMETER CUP


For measuring viscosities at elevated temperature,
Baroid offers thermostated cup heaters to fit the No.
28000 Baroid Rheometer or the FANN Viscometers.
The temperature can be adjusted and controlled up to
200°F, if desired. The cups can be furnished for 115, or
230-volt AC operation.
25120—Thermostated Cup Heater and Cup for Baroid Rheometer and No. 25120—
FANN V-G Meter, 115-volt AC Heated Rheometer Cup
25127—Cup Heater Rheometer, 230-volt AC
28049—BAROID RHEOMETER OR 28098—RHEOMETER REPAIR MANUAL
VISCOMETER INSTRUMENT CALIBRATION Baroid has developed this comprehensive manual for use
CHECK KIT in the repair and calibration of the Baroid Hand Crank
This kit is used for conveniently field checking the calibra- Rheometer Model 28000. Written and edited by techni-
tion of the Baroid Rheometer or any other Theological cians with years of experience in Rheometer repair, this
instrument. The kit contains certified-viscosity standard manual contains complete step-by-step instructions along
fluids in containers labeled with certification-standard with photos, illustrations, and drawings, and includes a
numbers with temperature/viscosity curves and tables. All complete parts list.
the physical data of these standards are traceable to the
National Bureau of Standards. 28200—CAPILLARY VISCOMETER
This kit contains all the necessary containers, ther- The Baroid Capillary Viscometer is a laboratory quality
mometers, and instructions for easily determining the extrusion viscometer capable of measuring shear stress
accuracy of any viscosity-measuring instrument to ± Vz over a wide range of shear rates. Most drilling fluids are
centipoise in the 20-27°C temperature range, and ± 1 subject to shear rates from 1 to 10 sec'1 in the pit to over
centipoise in the 100-300°F temperature range. 10,000 sec'1 at the bit. The Capillary Viscometer, with a
The No. 28049 kit contains:
range of from 10 to 100,000 sec'1, is a valuable rheolog-
One 19-27°C Thermometer (ASTM #17C) ical tool for measuring shear stress between these
Two Stainless Steel Cups with Brass Lids extreme limits.
Two Packages of Wipers The Baroid Capillary Viscometer operates by means of
Two Quart Containers Standard Calibration Fluid a pressurized mud chamber which expels the mud
Instructions, Fluid Data Tables, and Graphs
through a capillary tube. The pressure drop plus the flow
28622—RHEOMETER CALIBRATION STAND rate produced by the pressure differential provide the
necessary raw data for determining rheological values.
The Rheometer Calibration Stand has been developed for
Three tubes are included for full range operation.
recalibrating the No. 28000 Baroid Rheometer or the No.
A maximum mud temperature of 300°F is thermostati-
28600 Baroid Variable-Speed Electronic Rheometer.
cally controlled in a 1,000-cc reservoir. Precision pressure
28622—Rheometer Calibration Stand gauges measure the pressure drop of fluid flow through
the capillary tube. A maximum pressure differential of 375
psi is established by design of the instrument. Maximum
value and proper tube size selection allow for definition of
the type of flow, eliminating errors due to turbulent flow.
28200—Baroid Capillary Viscometer, 120-volt, 350-watt AC
28240—Baroid Capillary Viscometer, 230-volt, 350-watt AC

Licensed under Patent No. 3,353,403


No. 28622—
Rheometer Calibration Stand

RHEOMETER CALIBRATION FLUIDS


These are certified viscosity standard fluids in contain-
ers labeled with certification batch numbers. Each
container is supplied with a temperature/viscosity table
with the same batch number. Traceable to the
National Bureau of Standards.
28696—Calibration reference fluid, 10cP, 16oz(475ml)
28691—Calibration reference fluid, 20 cP, 16oz(475ml)
28692—Calibration reference fluid, 50 cP, 16oz(475ml)
28693—Calibration reference fluid, 100cP, 16 oz(475 ml)
28694—Calibration reference fluid, 200 cP, 16oz(475ml)
28695—Calibration reference fluid, 500 cP, 16oz(475ml) No. 28200—Capillary Viscometer
FANN Direct Indicating Viscometers Simplify and Quicken Scale Readings

FANN SERIES 35 VISCOMETERS


Series 35 Viscometers are versatile instruments for Twelve total test speeds let you measure over an
research or production use. They can be used wherever a extended shear-rate range. Test speeds of 600, 300,200,
regulated-frequency power source is available. 180,100, 90,60, 30,6, 3,1.8 and 0.9 rpm are available via
In the six-speed models, test speeds of 600, 300,200, a synchronous motor driving through an SR12 gear box
100,6 and 3 rpm are available via synchronous motor and then through the precision gearing, as defined for
driving through precision gearing. Any test speed can be Model 35. The additional 10:3 speed reduction is select-
selected without stopping rotation. The shear stress is able through a two-position gear-shift lever. Standard R1
displayed continuously on the calibrated scale, so that rotor sleeve, B1 bob and F1 torsion spring and stainless
time-dependent viscosity characteristics can be observed steel sample cup are included. The SR12 gear box can be
as a function of time. The Model 35A is powered by a 60- retrofitted to Series 35 Viscometers.
Hz motor; Model 35SA by a 50-Hz motor.

FANN Model 35 Viscometer FANN Model 35/SR12 Viscometer

30164—FANN Direct Indicating Viscometer, Model 35A. Six-speed 30166—FANN Direct Indicating Viscometer, Model 35A/SR12.12-speed
laboratory model for 115V 60-Hz use. Test speeds 600,300, laboratory model for 115-volt, 60-Hz power, Test speeds 600,
200,100,6 and 3 rpm for viscosity and gel strength. 115-volts, 300, 200,180,100, 90, 60, 30, 6, 3,1.8 and 0.9 rpm for viscosity
60-Hz, 0.75-amp power. Complete with: and gel strength, 115-volt, 60-Hz, 0.75-amp power. Complete
30752—Torsion spring assembly F1 with:
30847—Rotor sleeve, R1, chrome-plated brass 30752—Torsion spring assembly F1
30844—Bob, B1,303 stainless steel, hollow 30847—Rotor sleeve, R1, chrome-plated brass
30929—Stainless steel sample cup, scribed for 350 ml 30844—Bob, B1, 303 stainless steel, hollow
Instrument size: 15.2h x 6w x 10.5d inches (39 x 15 x 27 cm) 30929—Stainless steel sample cup, scribed for 350 ml
Instrument weight: 15 Ib (6.8 kg) Instrument size: 15.2h x 6w x 10.5d inches (39 x 15 x 27 cm)
Instrument weight: 17 Ib (7.7 kg)
30165—FANN Direct Indicating Viscometer, Model 35SA. Six-speed
laboratory model for 115-volt, 50-Hz use. Test speeds 600, 300, 30167—FANN Direct Indicating Viscometer, Model 35SA/SR12.12-
200,100,6 and 3 rpm for viscosity and gel strength, 115-volt, speed laboratory model for 115-volt, 50-Hz power. Test speeds
50-Hz, 0.60-amp power. Complete with: 600, 300, 200,180,100, 90, 60, 30, 6, 3,1.8 and 0.9 rpm for
30752—Torsion spring assembly F1 viscosity and gel strength. 115-volt, 50-Hz, 0.60-amp power.
30847—Rotor sleeve, R1, chrome-plated brass Complete with:
30844—Bob, B1, 303 stainless steel, hollow 30752—Torsion spring assembly F1
30929—Stainless steel sample cup, scribed for 350 ml 30847—Rotor sleeve, R1, chrome-plated brass
Instrument size: 15.2h x 6w x 10.5d inches (39 x 15 x 27 cm) 30844—Bob, B1, 303 stainless steel, hollow
Instrument weight: 15 Ib (6.8 kg) 30929—Stainless steel sample cup, scribed for 350 ml
Instrument size: 15.2h x 6w x 10.5d inches (39 x 15 x 27 cm)
Instrument weight: 17 Ib (7.7 kg)

Other torsion spring assemblies on FANN Models 34 and 35 can be


substituted to extend the torque measuring range or to increase the
sensitivity of the torque measurement.

For testing drilling fluids according to American Petroleum Insti-


tute Specifications RP 13B, the FANN Direct Indicating Viscome-
ters should include the following:
30752—Torsion spring assembly, F1
30847—Rotor sleeve, R1, chrome-plated brass, or
30844—Bob, B1, 303 stainless steel, hollow
30929—Stainless steel sample cup, scribed for 350 ml

8
FANN SERIES 34 VISCOMETERS Accessories To FANN Direct Indicating
Series 34 models feature two test speeds for viscosity,
600 and 300 rpm. They also have a neutral position for the Viscometers
determination of thixotropic gelation on oil well drilling
fluids according to established API procedures. These
instruments combine accuracy with simplicity of design,
and particularly are recommended for evaluating mate-
rials that are Bingham plastics. They now have applica-
tions in other fields. The Model 34A is driven by a 12-volt
AC/DC motor and has a provision for stirring the sample at
high speed (not a test speed). Model HC34A is hand- SAMPLE
cranked, and test speeds are controlled by a patented CUPS
governor design. Shear stress is read directly from a cali-
brated scale. Plastic viscosity and yield point of a fluid can Baroid Testing offers four sample cup types. Left to right stan-
be determined easily by making two simple subtractions dard stainless steel; insulated; thermocup; and double-wall cup.
from the observed data when the instrument is used with
R1-B1 combination and the standard F1 torsion spring Thermocup
(details for drilling fluids in American Petroleum Institute This electrically heated sample cup incorporates a preci-
Specification RP 13B). Other rotor-bob combinations and/ sion thermostat for close temperature control. Operating
or torsion springs can be used. R1 rotor sleeve, B1 bob, temperatures up to 200°F (93°C) are reached quickly and
F1 torsion spring and stainless steel sample cup are verified by an included dial-type thermometer. Made of
standard. Carrying case, step-down transformers and epoxy-finished aluminum alloy for better heat distribution
other accessories are available. and easy cleaning. 115- or 230-volt heaters.
31203—Thermocup, 115-volt. Electrically heated sample cup with ther-
mostat control for use to 200° F (93°C). Pins in base locate and
lock to platform of FANN Direct Indicating Viscometers. Com-
plete with metal-stem dial-type thermometer, Catalog No.
N7900.115-volt, 50- or 60-Hz, two-amp power.
31204—Thermocup, 230-volt. Electrically heated sample cup with ther-
mostat control for use to 200°F (93°C). Pins in base locate and
lock to platform of FANN Direct Indicating Viscometers. Com-
plete with metal-stem dial-type thermometer, Catalog No.
N7900. 230-volt, 50- or 60-Hz, one-amp power.

Double-Wall Circulating Cup


This double-wall, stainless steel cup holds 350 ml of test
fluid. It is designed for use with an external circulator to
control sample temperature. Pins in base locate and lock
to platform on Viscometer. Recommended for use at test
temperatures from 35° to 170°F (2° to 77°C).
FANN Model 34A FANN Model HC34A
Viscometer Viscometer 31759—Double-wall circulating cup. For use with external thermal liquid
circulator to control sample temperature. Stainless steel con-
struction, with scribe line for recommended immersion depth
using open-end rotor sleeves. Holds 350 ml of test fluid. Pins in
base locate and lock to platform on FANN Direct Indicating
30162—FANN Direct Indicating Viscometer, Model 34A. Two speeds, Viscometers. Recommended for use at test temperatures from
600 and 300 rpm for viscosity tests. Neutral position for determi- 35°tOl70 0 F(2°to77 0 C).
nation of gel strength. Field-portable, 12-volt AC or DC power.
Complete with: Insulated Sample Cup
30752—Torsion spring assembly, F1
30847—Rotor sleeve, R1, chrome-plated brass This insulated stainless steel sample cup is intended for
30844—Bob, B1, 303 stainless steel, hollow use with the closed-end rotor cups. It is designed for use
30929—Stainless steel sample cup, scribed for 350 ml with a refrigerated model circulator to control sample
Instrument size: 10h x 5.5w x 7d inches (25 x 14 x 18 cm) temperatures down to -40° F (-40°C). An aluminum cover
Instrument weight: 7 Ib (3.2 kg)
with access port for a nitrogen blanket minimizes frost
30163—FANN Direct Indicating Viscometer, Model HC34A. Two speeds, formation and is recommended for use at test tempera-
600 and 300 rpm for viscosity tests. Neutral position for determi- tures from-40° to + 170°F(-40°to +77°C). Pins in the
nation of gel strength. Field-portable. Test speeds are provided base locate and lock to the platform on Viscometer.
by a hand-operated, governor-controlled mechanism. Complete
with: 35283—Insulated sample cup. For low-temperature testing with closed-
30752—Torsion spring assembly, F1 end rotor cups R1 and R2. For use with external refrigerated
30847—Rotor sleeve, R1, chrome-plated brass model circulator to control sample temperature from -40° to
30844—Bob, B1, 303 stainless steel, hollow +170° F (-40° to + 77°C). Stainless steel cup with copper coils.
30929—Stainless steel sample cup, scribed for 350 ml Aluminum cover. Pins in base locate and lock to platform on
Instrument size: 10h x 5.5w x 7d inches (25 x 14 x 18 cm) FANN Direct Indicating Viscometers.
Instrument weight: 7 Ib (3.2 kg)
Standard Stainless Steel Cup
30929—Stainless steel sample cup, scribed for 350 ml sample volume to
give recommended immersion depth for use with open-end rotor
sleeves. Pins in base locate and lock to platform on FANN Direct
Indicating Viscometers.
ACCESSORIES TO FANN DIRECT INDICATING VISCOMETERS:
FULL AVAILABILITY AT VOLUME-PRODUCTION PRICES

ROTOR-BOB COMBINATIONS
Various bobs normally are used with the standard R1
rotor; various rotors normally are used with the standard
B1 bob. Selection should be made on the basis of the
shear gap, which dictates both the shear-rate range and
the maximum particle size of any solid species. The
shear-stress range and, hence, the viscosity range of
measurement can be adjusted according to the selection
of the torsion spring.

ROTORS
The outer cylinder normally supplied with the FANN Direct
Indicating Viscometer, the R1 rotor sleeve, has an open
bottom and chrome-plated brass construction. It also is
available in a 303 stainless steel construction and in a
in»*
«P -f I Tt.

closed-end, rotor-cup configuration. Three versions of the


R2 rotor are available for smaller gaps, higher shear
rates. An open-end R3 rotor is available in two configura-
tions, for a larger shear gap. Special rotors also can be
engineered to meet your special test requirements.
30847—Rotor sleeve, R1, chrome-plated brass
30849—Rotor sleeve, R2, chrome-plated brass
30851—Rotor sleeve, R3, chrome-plated brass
31716—Rotor sleeve, R1,303 stainless steel TORSION SPRING ASSEMBLIES
31718—Rotor sleeve, R2,303 stainless steel Torsion springs are readily interchanged on all models of
31720—Rotor sleeve, R3, 303 stainless steel FANN Direct Indicating Viscometers. Instruments nor-
35617—Rotor cup, R1, closed-end, stainless steel mally are supplied with the F1 torsion spring, which has a
35619—Rotor cup, R2, closed-end, stainless steel
spring constant of 386-dyne-cm/degree deflection and
provides a full-scale shear-stress capability of 1,533
dynes/cm2 at 300 degrees deflection with the B1 bob.
Other torsion spring assemblies are designed to be inte-
gral multipliers of the standard spring and can be used to
increase or decrease the shear-stress range and, hence,
the viscosity range of the instrument. Precision drawn and
tempered beryllium-copper wire assures the precision
and linearity and a long service life for these torsion
springs, even under adverse environments.
31068—Torsion spring assembly F0.2, Color Code Green
31069—Torsion spring assembly F0.5, Color Code Yellow
30752—Torsion spring assembly F1, Color Code Blue, standard shear-
stress range of 1,533 dynes/cm2 with bob, B1
31070—Torsion spring assembly F2, Color Code Red
BOBS 31071—Torsion spring assembly F3, Color Code Purple
The inner cylinder normally supplied, the B1 bob, is the 31072—Torsion spring assembly F4, Color Code White
standard for drilling fluids and cements and handles other 31073—Torsion spring assembly F5, Color Code Black
applications as well. This bob is 303 stainless steel 31074—Torsion spring assembly F10, Color Code Orange
for good wear resistance and is hollow for neutral buoy-
ancy, low rotational inertia and fast response in typical
test fluids. Recommended maximum-use temperature is
200°F (93°C). Three additional bobs are available and
normally are used with the R1 family of rotors. Special
bobs also can be engineered to meet your special test
requirements.
30844—Bob, B1, 303 stainless steel, hollow
30843—Bob, B2, 303 stainless steel
30842—Bob, B3, 303 stainless steel
30841—Bob, B4, 303 stainless steel

10
CIRCULATORS
Baroid now offers a family of FANN thermal liquid circula-
tors for use with the double-wall circulating cup or the
insulated sample cup for low temperature. These
precision-built circulators can be used with water or other
fluids to condition test samples thermally when the deter-
mination of viscosity must be made under the most pre-
cise measuring conditions. Interconnecting hoses,
clamps and fittings are included.
35293—A heat-only circulator, 90° to 212°F (35° to 100°C), four-liter
capacity. Accurate solid-state analog temperature control. 115-
volt, 60-Hz, 1,000-watt heater capacity. 6.75h x 12.5w x 13.5d
inches (17 x 31.5 x 34 cm). Shipping weight 22 Ib (10 kg).
35294—Refrigerated circulator, 0° to + 210°F (-20° to + 100°C), five-
liter capacity. Digital temperature selection and control to ±
0.2°F (± 0.1 °C) via platinum sensor and proportioned method
of heat control. Heater capacity 1,000 watts. Cooling capacity to
FANN Model DW-3 0° F (-20°C) is 65 minutes. 115-volt, 60-Hz. 9h x 15.5w x 21 d
Calibration Kit inches (23 x 39.5 x 55 cm). Shipping weight 62 Ibs (28 kg).

DW-3 CALIBRATING FIXTURE


Maintains accuracy of the torque measuring system on all
Series 34 and 35 models. Quickly determines condition of
bearings and accuracy of torsion-spring setting. Kit
includes support bracket, spool for bob shaft, five metric
weights and complete instructions. Silicone-oil calibration
reference fluids also can be used to verify overall accu-
racy of the viscometer.
31517—Calibrating fixture DW-3. Complete with support bracket, spool
for the bob shaft, five metric weights, spare thread, instructions
and case.

VISCOMETER CALIBRATION FLUIDS CARRYING CASES


30839—Viscometer carrying case for FANN Model 34A or Model
These are certified viscosity standard fluids in contain- HC34A
ers labeled with certification batch numbers. Each 30957—Viscometer carrying case for FANN Model 35A or 35SA
container is supplied with a temperature/viscosity table 31779—Viscometer carrying case with 230- to 115-volt transformer for
with the same batch number. Traceable to the FANN Model 35A or Model 35SA
National Bureau of Standards.
SR12 GEAR BOX ATTACHMENT
28696—Calibration reference fluid 10cP, 16oz(475ml) This attachment doubles the number of speeds obtainable
28691—Calibration reference fluid 20 cP, 16 oz(475 ml) from the Model 35A or Model 35SA FANN Direct Indica-
28692—Calibration reference fluid 50 cP, 16oz(475ml) ting Viscometers. To the normal speeds of 3,6,100,200,
28693—Calibration reference fluid 100cP, 16oz(475ml)
200 cP, 16 oz(475 ml)
300 and 600 rpm, this unit adds 0.9,1.8, 30,60,90 and
28694—Calibration reference fluid
28695—Calibration reference fluid 500 cP, 16 oz (475 ml) 180 rpm. These provide shear rates that cover an area of
great interest to many rheologists.
We recommend that you return your viscometer to our
Service and Repair Department for retrofitting the SR12
gear box attachment, or order both at once. If returning,
TRANSFORMERS please identify the serial number of your instrument.
11646—"Powr Pak", 115-volt to 12-volt
30168—Gear box attachment, SR12, for Model 35A FANN Direct Indica-
35114—"Powr Pak", 230-volt to 12-volt
ting Viscometer
35290—Inverter PV500B, 12-voit, DC input, 115-volt, AC output,
30173—Gear box attachment, SR12, for Model 35SA FANN Direct
500-watt continuous, input amps (no-load) 4,10-amp. Battery
Indicating Viscometer
charger, polarity protection, overload pilot light. Dimensions: 5h
x 9.5w x 9d inches (12.7 x 24.1 x 29.9 cm). Weight: 19 Ib (9 kg).
35291—Sine-wave inverter 5112-26,12/24 V, DC input, 115-volt, AC, GAS PURGE NIPPLE
60-Hz output, 250-VA output power, input current 32Aor 16A. If materials to be tested are volatile or if tests are to be
Frequency stability ±0.5%. Safety features include: input made at elevated temperatures, a source of clean, dry air
circuit breaker, reverse-polarity protection, overload and short-
circuit protection with automatic recovery. Dimensions: 7h x or nitrogen should be connected to a gas purge nipple,
19w x 13d inches (17.8 x 48.3 x 33.0 cm). Weight: 39 Ib (18 kg) which is substituted for a plugscrew normally supplied
with Series 34/35 FANN Direct Indicating Viscometers.
Pressure of the purging gas should not exceed five psig.
30036—Gas purge nipple
11
FANN Model 39B Recording Rheometer: Engineered to Give You Accurate
Characterization of Flow Behavior.
This Couette-type coaxial cylinder rheometer is 30107—Torsion spring assembly, No. 340. Color Code Blue. Standard
designed by Baroid for the rheological characteriza- shear-stress range of 4,000 dynes/cm2 with bob B1. Maximum
sensitivity 200 dynes/cm2, full scale.
tion of all types of shear-rate-dependent and time- 31712—Torsion spring assembly, No. 380. Color Code Red. Provides
dependent fluids in cgs units (centipoise) or SI units twice the standard shear-stress range with bob B1. The max-
(Pascal-seconds). Data outputs of shear stress and imum range is 8,000 dynes/cm2 and maximum sensitivity is 400
shear rate are recorded on an XY recorder. Other dynes/cm2, full scale.
31713—Torsion spring assembly, No. 320. Color Code Yellow. Provides
recorder options are available. The temperature of the half the standard shear-stress range, but double sensitivity. With
sample can be measured with a thermocouple located bob B1, the maximum range is 2,000 dynes/cm2 and maximum
in the tip of the bob shaft. sensitivity is 100 dynes/cm2.
Fixed rotor speeds and linear-speed programs to 31714—Torsion spring assembly, No. 310. Color Code Green. Provides
600 rpm are possible. The Thermobath accessory one-quarter the standard shear-stress range. With bob B1, the
maximum range is 1,000 dynes/cm2 and maximum sensitivity is
allows sample temperatures to 220°F (105°C). 50 dynes/cm2.
Standard shear stress range is 0 to 4,000 dynes/cm2, 35472—Rotor cup, R1, plated brass. Closed-end construction.
full scale. Shear rate is 0 to 1,024 sec' with the stan- Radius R0 = 1.8415 cm. Sample volume with bob B1 is 34
dard rotor and bob; other options are available. ml. Complete with removable bottom cap and O-ring.
31949—Rotor cup, R2, plated brass. Closed-end construction. Radius R,
= 1.7588 cm. Sample volume with bob B1 is 32 ml. Complete
30009—FANN Model 39B Recording Rheometer. Speed range 0 to 600 with removable bottom cap and O-ring.
rpm. Selectable fixed rotor-speed and linear-speed programs. 30135—Bob, 81, for Model 39 or Model 50 Rheometers. 303 stainless
Standard shear-stress range 0 to 4,000 dynes/cm2 with 5- steel, solid bob. Radius R, = 1.7245 cm. Length L = 7.60 cm.
position switch; 0 to 1,024 sec1.115-volt, 50 or 60-Hz, 1.25-amp 30089—Bob, B2, for Model 39 or Model 50 Rheometers. 303 stainless
power. steel, solid bob. Radius R, = 1.2276 cm. Length L - 7.60 cm.
Supplied complete with: 30091 —Bob, B3, for Model 39 or Model 50 Rheometers. 303 stainless
30107—Torsion spring assembly, No. 340, standard steel, solid bob. Radius R: = .8622 cm. Length L - 7.60 cm.
30056—Rotor cup assembly, R1 30098—Bob, B4, for Model 39 or Model 50 Rheometers. 303 stainless
30135—Bob, B1 steel, solid bob. Radius R: = .8622 cm. Length L = 3.80 cm.
33292—Recorder cable, 2 supplied 35284—Calibrating fixture, Model DW-7. Complete with support bracket,
33295—Thermocouple, Type J, for sample temperature calibration bob, 6 metric weights to index shear-stress range on
Instrument size: 19.5h x 11,5w x 6.25d inches (49.5 x 29.2 x 15.9 cm) the recorder, spare thread, instructions and case.
Instrument weight: 23 Ib (10 kg) 28691—Calibration reference fluid, 20 cR 16oz(475ml)
28692—Calibration reference fluid, 50 cR 16 oz (475 ml)
ACCESSORIES 28693—Calibration reference fluid, 100cR 16oz(475ml)
35430—Model XY, YT Recorder. Paper size 11x17 inches, DC precision 29894—Calibration reference fluid, 200 cR 16 oz (475 ml)
attenuator on X and Y with calibrated ranges and variable con- 28695—Calibration reference fluid, 500 cR 16 oz (475 ml)
trol. Switches to time-base operation on X channel, 11 sweep 33167—Chart paper, ten 1-inch by twelve 1 '/4-inch grid area, 11 x 17-
ranges. 115- or 230-volt, 50- or 60-Hz, 1 -amp power. inch overall size, box of 100 sheets
32856—Transformer 230 to 115-volt. For operation of Model 39B Rhe- 33165—Chart paper, ten '/2-inch by twelve 3/<-inch grid area, 8'/2 x 11-
ometer from 230-volt power source. inch overall size, box of 100 sheets
31661—Thermobath, 115-volt. Electrically heated sample bath with 35431 —Ink cartridge for XY Recorder, Red, each
powerstat control for use to 220° F (105°C). Contains coil for 35433—Ink cartridge for XY Recorder, Blue, each
optional use with an external circulator to control temperature 35432—Ink cartridge for XY Recorder, Black, each
down to 35° F (1.7°C). Mounts to pin on FANN Model 39B Rhe- 31842—Operating instructions for FANN Model 39B Rheometer
ometer. Complete with metal-stem dial-type thermometer, Cat-
alog No. 10364.115-volt, 50- or 60-Hz, 2-amps power.
35294—Refrigerated circulator, 0° to +210°F (-20° to +100°C),
5-liter capacity. Digital temperature selection and control
to ±0.2°F (±0.1CC) via platinum sensor and proportioned
method of heat control. Heater capacity: 1,000 watts.
Cooling capacity to 0°F (20°C) is 65 minutes. 115-volt,
60-Hz, 9h x 15.5w x 21 d inches (23 x 39.5 x 55 cm).
Shipping weight: 62 Ib (28 kg)

12
FANN Model 5STDL Consistometer:
A Multi-Use Telescopic Shear Viscometer.
This is a high-pressure, high-temperature instrument in 30224—Tube cleaner
which the test fluid is subjected to telescopic shear. It F0214—Fill gauge
originally was designed for the oil industry and is par- 31840—Operating instructions
Instrument size: 20h x 18w x 22d inches (46 x 51 x 56 cm)
ticularly useful in determining the flow properties of Instrument weight: 145 Ib (66 kg)
drilling mud, cements and fracturing fluids under down-
hole conditions. The upper operating limits of the 35462—FANN Model 5STDL Consistometer, 230-volt. Telescopic
5STDL are 20,000 psi and 500°F (260°C). shear viscometer for use to 20,000 psi and 500°F (260°C). 230-volt,
50-Hz, 6-amps power.
The test fluid is sheared in the annular space INCLUDES:
between two coaxial cylinders, the outer cylinder form- 30528—Type E bob, standard
ing the sample container and the moving bob being 33286—Recorder cable assembly
the inner member. Axial movement of the iron bob is 33287—Thermocouple cable assembly, 17-inches, Type J
caused by two alternately energized electromagnets 31199 to 31201—set of 3 wrenches
L4026—Valve seal lubricant, 2 oz (57 g)
positioned at the ends of the sample cavity. Bob move- 31367—Hydraulic fluid, 1 quart (950 ml)
ment is proportional to the viscosity of the test fluid. 30224—Cleaner
The consistency, or relative viscosity, of the test fluid is F0214—Fill gauge
obtained by electrically timing the movement of the 31840—Operating instructions
Instrument size: 20h x 18w x 22d inches (46 x 51 x 56 cm)
steel bob in the heated and pressurized sample con- Instrument weight: 145 Ib (66 kg)
tainer. Sample temperature is measured in the test
zone. ACCESSORIES
A constant force is imposed on the bob by electro- 35470—Dual-pen strip chart recorder, 115-volt. Paper size 10-
magnets, through the proper selection of current. inches. 115-volt, 50 or 60-Hz, 1-amp power.
Pressure is recorded on a 6-inch-diameter dial gauge. 35471—Dual-pen strip chart recorder, 230-volt. Paper size 1 fl-
inches. 230-volt, 50 or 60-Hz, 0.5-amp power.
Data outputs of consistency (relative bob travel time) 30528—Type E Bob, standard, for FANN Model 5STDL
and sample temperature can be recorded on a dual- Consistometer
pen strip chart recorder. Available for 115-volt or 230- 31697—Type С Bob, with rubber bumpers, for FANN Model 5STDL
volt operation. Consistometer
33177—Chart paper for strip chart recorders. Ten 1 -inch by continu-
ous 1-inch grid area. Roll of 100 feet.
35461—FANN Model 5STDL Consistometer, 115-volt. Telescopic 33170—Ink cartridge for strip chart recorder, Red, each
shear viscometer for use to 20,000 psi and 500°F (260°C). 115-volt, 33172—Ink cartridge for strip chart recorder, Blue, each
60-Hz, 12-amps power. 31840—Operating instructions for model 5STDL Consistometer
INCLUDES:
30528—Type E bob, standard
33286—Recorder cable assembly
33287—Thermocouple cable assembly, 17-inches, Type J
31199 to 31201 —set of 3 wrenches
L4026—Valve seal lubricant, 2 oz (57 g)
31367—Hydraulic fluid, 1 quart (950 ml)

13
FANN Model 70 HTHP Viscometer
The Model 70 Viscometer is a new, direct-indicating coaxial cylinder viscometer specially developed to measure fluid
Theologies under extremely high pressures (20,000 psig) and temperatures (500° F). Because of its relatively compact
size it can be used onsite as well as in a laboratory, and represents a significant cost saving over instruments of similar
capabilities.
The Model 70 Viscometer consists of three major compo- System features:
nents: the Control Console, the Remote Test Station, and Pressure to 20,000 psig
the Test Cell. Hand-operated Hydraulic Pump
Digital pressure Readout
The Control Console—Contains all controls and dis-
Digital Temperature Control
plays, power supplies, the pressurization pump and reser-
Ramp and Soak Capabilities
voir, the over-pressure relief rupture disk, and a removable
Electronic Speed Control
cell preparation station.
Digital rpm Display
The Remote Test Station—Contains the magnetic tor- Fixed and Variable Speed
sion angle sensor, the magnetic cell drive, the cell Rapid Water Cool-down
heaters, the water cool-down system, temperature API-type bob
sensor, and cooling fans. Sample circulation to prevent settling
Digital readout of shear stress in degrees
The Test Cell—The cell is made of corrosion-resistant
metals and is designed for 20,000 psig operation at 500° F
Instrument Size and Weight:
It includes a torsion assembly that uses an American Test Cell Size: 15-in. high x 4УНп. diameter
Petroleum Institute (API) type bob and rotor geometry. The Weight: approximately 32 Ib
rotor has external flights to induce circulation. Shield Size: 36-in. high x 17-in. wide x 24-in. deep
Weight: approximately 169 Ib
Console Size: 17-in. high x 24-in. wide x 20-in. deep
Instrument Specifications: Weight: approximately 112 Ib
Rotor Speed, rpm (nominal) 3 to 600
Fixed Speeds (rpm) 600,300,200,100,3
35500—FANN Model 70 HTHP Viscometer, 115/230-volt, 60/50-Hz
Rotor Radius, R0, cm 1.8415
Bob Height, L, cm 3.805
Shear Gap in Annulus, cm 0.1170 Accessories and Parts for Model 70 Viscometer.
Radii Ratio, R,/R0 0.9365 31154—Rupture, Disk, 1/4 23 К Inconel
Shear Rate constant, K3, 31572—BearTrac, Pressurization Fluid
1
sec' per rpm 1.7023 35518—Bushing, Pivot
Overall Instrument Constant К 300 35526—Bushing, Rotor
Shear Stress Accuracy ±0.5%F.S. 35562—Back Up Ring, Upper
Maximum Use Temperature, °F 500 35563—Back Up Ring, Lower
Minimum Use Temperature Ambient A4002—Jewel
Pressure rating psi 20,000 A4004—Bearing, Angular Contact
Sample Volume 175 ml (nominal) C6021—Vent Valve Seat, Stainless
Power 115/230-volt, 60/50-Hz, 1KVA C6023—Vent Valve Stem, Stainless
Viscosity Range 0-300 centipoise @ 300 rpm C6025—Vent Valve, Packing
Minimum Viscosity 5 centipoise @ 600 rpm E5004—Motor Brush
Maximum Viscosity 300 centipoise @ 300 rpm E8001—"O" Ring, Upper Cell Assembly
E8002—"O" Ring, Lower Cell Assembly
E8004—"O" Ring, Port Connectors
I3004—Transistor Mosfet MTP 12N20
J1003—Hydropac Pump Seal Kit

14
FANN Model 50C Recording High-Temperature Rheometer:
A General Purpose Instrument with High-Pressure Capability.
Baroid's FANN 50C Recording High-Temperature 35014—FANN Model 50C Recording High-Temperature Rheometer, 115-
Rheometer is a rotational-type viscometer that tests volt. Speed range 0 to 600 rpm, selectable fixed-speeds and
linear-speed programs. Temperature range to 500° F (260°C);
sample fluids to 500°F (260°C) in a pressurized coaxial linear-temperature program from 15 to 200 minutes. Pressure
cylinder chamber. Heat can be programmed or con- range: 0 to 1,000 psig with hydraulic fluid or with bottled
trolled manually. Dual pressure system capability now nitrogen. Standard shear-stress range: 0 to 4,000 dynes/cm2
is standard on all models. The test sample can be with 5-position switch; 0 to 200 dynes/cm2 maximum sensitivity.
pressurized to 1,000 psi (7,000 kPa) with either a Shear-rate range: 0 to 1,024 sec'1,115-volt, 50 or 60-Hz, 10-
amps power.
hydraulic liquid or with bottled gas, such as nitrogen. INCLUDES:
Apparent viscosities at various rates of shear, time- 30310—Torsion spring assembly, No. 440
dependent properties, change caused by continued 30326—Rotor cup, R1, high pressure
shearing and temperature effects are determined 30135—Bob, B1
32954—Recorder cable assembly
quickly and accurately. The Model 50C is ideal for gen- 33301—Thermocouple Type J for sample temperature
eral rheology characterization, including determining 33320—Dual-pen strip chart recorder, 115-volt
the high temperature stability of drilling fluids. 31957—Sample fill gauge
Shear-stress output, rotor speed and bath tempera- 30439—Tommy bar for sample cup
ture are displayed on a digital meter and/or simultane- 31202—Pin spanner wrench for M50C
31606 to 31614—set of 6 hex key wrenches
ously recorded. Data outputs readily are converted to 31571—Heater bath oil, 1 quart, 2 supplied
the U.S. customary system, or to cgs or SI metric sys- 31572—Rheometer head oil, 1 quart, 2 supplied
tems. Shear stress with the standard spring provides Instrument size: 64h x 31 w x 16d inches (163 x 79 x 41 cm)
4,000 dynes/cm2, full scale, in five selectable ranges Instrument weight: approximately 250 Ib (114 kg)
down to 200 dynes/cm2. Shear rate is 0 to 1,024 sec 1 35107—FANN Model 50C Recording High-Temperature Rheometer, 230-
with the standard rotor and bob. Other torsion springs volts. Speed range: 0 to 600 rpm selectable fixed-speed and
or bobs are available. linear-speed programs. Temperature range to 500° F (260°C);
Automatic test parameters can be set before test linear-temperature program from 15 to 200 minutes. Pressure
range: 0 to 1,000 psig with hydraulic fluid or with bottled
begins. At a touch of a button, the rotor accelerates to nitrogen. Standard shear-stress range: 0 to 4,000 dynes/cm2
the preset speed at the rate selected. Upon reaching with 5-position switch: 0 to 200 dynes cm2 maximum sensitivity.
this point, deceleration is initiated, returning rotor rpm Shear-rate range: 0 to 1,024 sec"1, 230-volt, 50 or 60-Hz, 5-amps
to zero at the controlled rate. power.
INCLUDES:
The dual-pen strip chart recorder (included) oper- 30310—Torsion spring assembly No. 440
ates in time-base mode or as a function of speed pro- 30326—Rotor cup, R1, high pressure
gram. Records shear stress, shear rate and sample 30135—Bob, B1
temperature. Other recorder options are available for 32954—Recorder cable assembly
115-volt or 230-volt power. 33301—Thermocouple Type J for sample temperature
33321—Dual-pen strip chart recorder, 230-volt
31957—Sample fill gauge
SPECIAL ALLOY COMPONENTS FOR 30439—Tommy bar for sample cup
CORROSION RESISTANCE 31202—Pin spanner wrench for M50C
31606 to 31614—set of 6 hex key wrenches
The following components have been used for testing 31571—Heater bath oil, 1 quart, 2 supplied
acidizing/fracturing fluids in the oil industry and they 31572—Rheometer head oil, 1 quart, 2 supplied
are recommended whenever the need for high level of Instrument size: 64h x 31 wx 16d inches (163x79x41 cm)
corrosion resistance is dictated by the nature of the Instrument weight: approximately 250 Ib (114 kg)
test fluid. We recommend that all four components,
namely rotor cup, bob, bob shaft and expansion fitting,
all be substituted as a unit in order to ensure the maxi-
mum protection to the Model 50 Rheometer.

35266—Rotor Cup, R1, Hastelloy®, high-pressure, closed-end construc-


tion. Radius R0 = 1.8415 cm. Sample volume with bob, B1, is 38
ml.
35259—Bob, B1, Hastelloy, solid bob. Radius R. = 1.7245 cm. Length L.
= 7.60cm.
35273—Bob, B2, Hastelloy, solid bob. Radius R( = 1.2276 cm. Length L
= 7.60cm.
35263—Bob shaft, Hastelloy
35267—Expansion fitting, Hastelloy

These components can be retrofitted to any existing


Model 50C FANN High-Temperature Recording Rheom-
eter, or as an option on a new installation.

15
Digital Control Option (DCO) for the FANN Model 50C

Hewlett Packard Digital Control Option Epson LX-800 Printer


HP7475-01 Plotter (DCO)

The Digital Control Option is an on-board computer which


replaces the standard Model 50C control panel. The unit
contains a 5-inch screen which displays Viscosity, Shear
Stress, Shear Rate, Bath Temperature, Sample Tempera-
ture, and Pressure on a real-time basis. It allows for the
programming and storing of up to 99 test sequences, and
each sequence can consist of up to 999 separate steps of
changes in shear rate or temperature. The unit also allows
the selection of the way in which the data is taken, as a
function of changes in time, shear rate (rpm), shear
stress, or sample temperature. The unit contains an
internal 20 Mbyte hard disk for data storage of not only the
test results but also the test sequences. The system has
options for printing and plotting data in real time or storing
for retrieval and analysis later. The system allows the
selection of one of three measurement systems that can
be changed at the touch of a key.

Package Includes:
Parallel Interface for an Epson Printer
Serial Interface for a Hewlett Packard Plotter
Pressure Transducer Assembly (0 to 1000 psi range)
Solenoid Valve for Oven Cooling Control
CRT Display (Built-in)
20 Mbyte Hard Disk Storage
12 Key Keyboard for entry of test profiles
All Hardware required to retrofit to a FANN Model 50C
Rheometer
35642—Digital Control Option
35643—Epson Printer
35644—Hewlett Packard Plotter

FANN Model 50C Viscometer


with DCO, Plotter and Printer

16
FANN Model 50C Options
35640—FANN Model 50C Recording High-Temperature Rheometer, 35640—Model 50C Rheometer with Digital Control Option, 115-volt, 60-
with Digital Control Electronics Package. Provides extended Hz, 10-amp
end-user rheology capabilities by offering the opportunity to 35641 —Model 50C Rheometer with Digital Control Option, 230-volt, 50-
automatically capture complex testing profiles through a menu- Hz, 5-amp
driven system. Powerful internal computer with 640K RAM and 35665—Model 50C Rheometer with Analog Interface Option, 115-volt,
20 Mbyte hard disk. Programmable speed and temperature pro- 60-Hz, 10-amp
files. Selectable data archival as a function of time, shear 35666—Model 50C Rheometer with Analog Interface Option, 230-volt,
stress, shear rate, or sample temperature. Pressure range: 0 to 50-Hz, 5-amp
1,000 psig with oil or nitrogen, torsion spring assembly No. 440; 35642—Digital Control Option Electronics Package, 115/230-volt
R1 rotor cup and B1 bob. Shear stress range: 0 to 4,000 35495—Analog Interface Option Electronics Package, 115/230-volt
dynes/cm2 standard. Shear rate range: 0 to 1,024 sec' stan- 35014—Model 50C Rheometer, with manual control, 115-volt, 50/60-Hz,
dard. 115-volt, 60-Hz, 10-amps power. Accessories include: 10-amp
Calibrating fixture, model DW-6 35107—Model 50C Rheometer, with manual control 230-volt, 50/60-
Sample fill gauge Hz, 5-amp
Tommy bar for sample cup
Pin spanner wrench
Set of 9 hex key wrenches
ACCESSORIES
33320—Model 3320 dual-pen strip chart recorder, 115-volt. Paper size
Heater bath oil, 2 quarts
10-inches. 115-volt, 50 or 60-Hz, 1 -amp power.
Rheometer head oil, 2 quarts
33321—Model 3321 dual-pen strip recorder, 230-volt, 0.5-amp. Paper
Digital Control Option features:
size 10-inches. 230-volt, 50 or 60-Hz, 0.5-amp power.
Parallel interface for an Epson printer
30310—Torsion spring assembly No. 440. Color Code Blue. Standard
Serial interface for a Hewlett Packard plotter
shear-stress range of 4,000 dynes/cm2 with bob, B1. Maximum
CRT display (built-in)
sensitivity: 200 dynes/cm2, full scale.
Disk storage of programs and data F1302—Torsion spring assembly No. 480. Color Code Red.
Digital keyboard for entry of test profiles
Provides twice the standard shear-stress range with bob,
Optional Equipment:
B1. The maximum range is 8,000 dynes/cm2 and maximum
35643—Epson LX800 Printer
sensitivity is 400 dynes/cm2, full scale.
35644—Hewlett Packard HP7475-01 Plotter
31303—Torsion spring assembly No. 420. Color Code Yellow. Provides
35665—FANN Model 50C Recording High-Temperature Rheometer, half the standard shear-stress range, but double sensitivity. With
with Analog Interface Electronics Package. Provides connection bob, B1, the maximum range is 2,000 dynes/cm2 and maximum
with host computer for improved data archival and fully automat- sensitivity is 100 dynes/cm2.
ic operation available through the use of user provided program- 31304—Torsion spring assembly No. 410. Color Code Green. Provides
ming and software. Pressure range: 0 to 1,000 psig with oil or one-quarter the standard shear-stress range. With bob, B1, the
nitrogen. Temperature range to 500"F (260°C). Torsion spring maximum range is 1,000 dynes/cm2 and maximum sensitivity is
assembly No. 440; R1 rotor cup and B1 bob. Shear stress 50 dynes/cm2.
range: 0 to 4,000 dynes/cm2 with 5-position switch; 0 to 200 30326—Rotor cup, R1, high-pressure, stainless steel, closed-end con-
dynes/cm2 maximum sensitivity. Shear rate range: 0 to 1,024 struction. Radius R01.8415 cm. Sample volume with bob, B1, is
sec', 115-volt, 60-Hz, 10-amps power. Accessories include: 38ml.
30135—Bob, B1, for Model 39 or Model 50 Rheometer. 303 stainless
Dual-pen chart recorder
steel, solid bob. Radius R, = 1.7245 cm. Length L = 7.60 cm.
Recorder cable assembly
30089—Bob, B2, for Model 39 or Model 50 Rheometer. 303 stainless
Calibrating fixture, Model DW-6
steel, solid bob. Radius R; = 1.2276 cm. Length L = 7.60 cm.
Sample Fill Gauge
30091—Bob, B3, for Model 39 or Model 50 Rheometer. 303 stainless
Tommy bar for sample cup
steel, solid bob. Radius R; = 0.8622 cm. Length L = 7.60 cm.
Pin spanner wrench
30098—Bob, B4, for Model 39 or Model 50 Rheometer. 303 stainless
Set of 9 hex key wrenches
steel, solid bob. Radius Ri = 0.8622 cm. Length L = 3.80 cm.
Heater bath oil, 2 quarts
35289—Calibrating fixture Model DW-6. Complete with support bracket,
Rheometer head oil, 2 quarts
stainless steel calibration bob, 6 metric weights to index shear-
The following Analog outputs are provided:
stress range on the recorder, spare thread, instructions and
A) Torque Transducer Output: ± 5.0-volts DC
case.
B) Tachometer Output: 0 to 5.0-volts DC
33177—Chart paper for strip chart recorder, ten 1-inch by continuous 1-
C) Bath and Sample Output: 0 to 5.0-volts DC
inch grid area. Roll of 100 feet.
D) Pressure Transducer Output: 0 to 5.0-volts DC
33170—Ink cartridge for strip chart recorder, Red, each
The following controls are provided:
33172—Ink cartridge for strip chart recorder, Blue, each
A) Rotor Speed Control with Analog Input of 0 to 5-volts DC, for 0 to 31571—Heater bath oil, quart (950 ml). For Model 50C and Model 398
600 rpm
Rheometers
B) Heater Control with Analog Input of 2 to 5-volts DC for 0 to 100% 31572—Rheometer head oil, quart (950 ml), for Model 50C Rheometer
heater power
31841—Operating instructions for FANN Model 50C Recording High-
C) Gain and Offset Controls for scaling each channel to 0 to 5.0-volts
Temperature Rheometer
DC
35643—Epson LX80 Printer, 115-volt
35644—Hewlett Packard HP7475-01 Plotter, 115-volt, complete with
35495—Analog Interface Electronics Package for direct retrofit to a paper and pens
FANN Model 50C Rheometer. Package includes all required
installation connectors, Pressure Transducer Assembly (0 to VISCOMETER CALIBRATION FLUIDS
1,000 psi range). Analog Interface Electronics provides the
following: These are certified viscosity standard fluids in contain-
A) Rotor speed control circuitry with analog input of 0 to 5.0-volts DC, ers labeled with certification batch numbers. Each
for 0 to 600 rpm container is supplied with a temperature/viscosity table
B) Heater control with analog input of 2 to 5-volts DC for 0 to 100% with the same batch number. Traceable to the
heater power
C) Digital display of analog voltage level for selected outputs National Bureau of Standards.
D) Gain and offset controls for scaling of each channel to 0 to 5.0- 28696—Calibration reference fluid, 10 cP, 16 oz (475 ml)
volts DC 28691—Calibration reference fluid, 20 cP, 16 oz (475 ml)
E) Terminals for analog inputs and outputs 28692—Calibration reference fluid, 50 cP, 16 oz (475 ml)
F) Analog outputs of 0 to 5.0-volts DC for: 28693—Calibration reference fluid, 100 cP, 16 oz (475 ml)
1. Torque Transducer 28694—Calibration reference fluid, 200 cP, 16 oz (475 ml)
2. Tachometer 28695—Calibration reference fluid, 500 cP, 16 oz (475 ml)
3. Bath and Sample Thermocoupler
4. Pressure Transducer

17
40001—SAND CONTENT KIT
The Baroid Sand Content Kit is a simple, accurate and
inexpensive sieve analysis apparatus for determining the
sand content of drilling muds.
The kit consists of a special 200-mesh sieve 2Vz in. in
diameter, fastened inside a collar upon either end of which
fits a small funnel. This is used with a sand content tube.
The collar and funnel are made of polyethylene; the
screen is made of brass.
Use of the Baroid Sand Content Kit conforms to API
recommendations, RR No. 13B.

Complete Unit
40001—Baroid Sand Content Kit complete with sieve, funnel, measuring
tube, and wash bottle in plastic case
No. 10871 —Wet Screen Analysis Kit

Sand Content Kit Parts


40002—Wash Bottle, 500 ml 10871—WET SCREEN ANALYSIS KIT
40003—Plastic Carrying Case
40101—Sieve, 200-mesh
Designed to give a simple, accurate and reproducible
40201—Funnel test method for particle size analysis by wet sieving,
40300—Tube, glass sand content, capacity 10 ml, marked for mud as required for particle size analysis for fines in barite
samples and graduated for 0 to 20% sand as specified in API 13A. The kit consists of a 3.06 inch
diameter by 3.38 inch tall screen holder and a spray
wash assembly with a No. 1/4 TTG 6.5 spray nozzle
and a flow pressure regulator for 0 to 30 psig. The kit
is complete with two 4 x 4 inch screens for use as
U.S. Standard Sieves No. 200 and No. 325 and is
ready for hook-up to a water source.
10871 —Test Kit for Particle Size by Wet-Sieve Analysis
INCLUDES:
10873—Screen Holder and Cap
—Spray Wash Assembly, with a No. 1/4-TTG 6.5 Spray Nozzle,
24 inch Black Hose, Pressure Regulator, Gauge for 0 to 30
psig, and 1/8-NPT Adapter Plug for connection to water
supply
No. 40001—Sand Content Kit 10872—U.S. Standard Sieve No. 200, 75u.m sieve opening
10874—U.S. Standard Sieve No. 325,45u.m sieve opening

N9202—PARTICLE SIZE PLATE KIT


The Baroid Particle Size Plate is used to make onsite
tests of the effectivity of solids control equipment. The
tests are simple, repeatable and easy to perform. A
sample of drilling fluid is "drawn down" across the
plate. An inspection procedure is used to determine the
size of the largest particles in the drilling fluid sample.

Complete Unit
N9202—Baroid Particle Size Plate Kit complete with Particle Size Plate,
Demonstration Fluid and instructions in plastic carrying case
N9200—Baroid Particle Size Plate only
N9210—Demonstration Fluid, 100 Micron
N9235—Demonstration Fluid, 35 Micron
N9290—Demonstration Fluid, 90 Micron
65305—Carrying Case No. 11306—Digital Hygrometer

11306—DIGITAL HYGROMETER
The 880 hand-held indicator is a rugged, portable device
designed to give accurate readings of temperature and
humidity over a broad range of conditions. It is extremely
compact and light in weight. The probe and main body are
factory matched. Field-selectable adjustment allows multi-
ple and interchangeable sensors. Range: 0%to 100% RH,
Accuracy: ± 2%, Power: 9-Volt Battery.

11306—Digital Hygrometer complete with battery and carrying case


No. N9202—Particle Size Plate Kit
18
65300—BAROID RESISTIVITY METER MODEL 88C RESISTIVITY METER
The Baroid Resistivity Meter is a solid-state, electronic This instrument features solid state electronics and is
meter for measuring the resistivity of fluids, slurries or designed to meet the needs of field and laboratory
semi-solids having resistivities of 0.01 to 10 ohmsmeter2/ personnel for resistivity measurement according to the
meter. Measurements can be made quickly and accu- API procedure. It is suitable for filtrates, muds, filter
rately. Conductivity of the medium being measured is cakes, or slurries and provides a direct digital readout
obtained by taking the reciprocal of the resistivity mea- of resistivity in three ranges: 2, 20 and 200 ohm-
surement. meters. A built-in temperature probe provides direct
Overall dimensions are 6 Vi-in. x 311/16-in. x 213/16-in. measurement of the sample temperature in the trans-
Weight is only two pounds. A carrying case and plastic parent cell. The instrument features high accuracy and
laminated temperature conversion chart are furnished at has a built-in "Test" circuit to check calibration. It is
no extra cost. packaged in a lightweight high-density polypropylene
case and is suitable for onsite testing. The unit is pow-
Major Advantages ered by six "AA" cells, or by 115-volt, 60-Hz. Batteries
• Transparent lucite sample cell is easily removed and cleaned
• Thermometer is an integral part of sample cell are automatically disconnected from circuit when
• Transistor circuit and readily available parts using battery eliminators.
• Long battery life
• Rugged construction—suitable for field use
• Small size, lightweight for easy field transportation 31763—FANN Model 88C Resistivity Meter, complete. Includes sample
• Single direct reading scale cell, built-in temperature probe, three range selector switch for
• High degree of accuracy resistivity to 2,20 and 200 ohm-meters, test circuit, and polypro-
• Reproducible results pylene case. Battery powered or can be used with battery
• Measures resistivity of mud, filter cakes and other slurries eliminator.
INCLUDES:
65300—Baroid Resistivity Meter, complete in plastic case 30251 —Sample Cell, transparent, plastic body. For testing liquids or
L4422—Battery for Baroid Resistivity Meter, 22.5-volt filter cake. Temperature well for insertion of temperature
N8201—Thermometer, 40° to 110°F, for No. 65300 Resistivity Meter probe. Cell constant С = 5000 (or К = 0.000200)
65314—Resistivity Probe (Sample Cell) 33041 —Battery, 1.5-volt, type "AA", 6 supplied
B1011—Carrying Case 31959—Battery Eliminator, 115-volt, 60-Hz to 12-volt DC
Instrument size: 3.5h x 10w x 7.5d inch (89 x 254 x 190 mm)
Instrument weight: 2.8 Ib (1.27 kg)
/Accessory:
31960—Battery Eliminator, 230-volt, 50-Hzto 12-volt DC

No. 65300—Baroid Resistivity Meter

65510—BAROID EMULSION
TEST CELL
The Baroid Emulsion Test Cell approximates the high
shear that fluids experience in high pressure flow through
small orifices, and is ideally suited for laboratory and field
testing of water/oil mixtures. Additionally, the effect of
chemical additions on the emulsion properties of the mix- No. 31763-FANN Model 88C Resistivity Meter
tures can be quickly evaluated prior to field treatment.
The Baroid Emulsion Test Cell provides instantaneous
readings on foam, oil, emulsion and water volumes.
65510—Baroid Emulsion Test Cell
65511—Valve Stem Adapter
38713—Valve Stem

No. 65510—Pressure Emulsion Test Cell

19
pH TESTING EQUIPMENT AND ACCESSORIES

60006—LAB MODEL DIGITAL pH METER


The Baroid Lab Model Digital pH Meter is a high-quality,
bench-type lab pH meter designed to measure the entire
pH scale (0-14). This meter has a wide millivolt range (±
1999) and easily converts from 115 to 230 volts AC power
by use of a conveniently mounted switch. The unit pro-
vides accuracy and readability of .02 pH and 2 millivolts.
The automatic temperature compensation (АТС) range
on this instrument runs from 0° to 100° Centigrade. The
АТС probe (included with meter) plugs into the front panel
of the meter and automatically adjusts the readout to
measure temperature variations in the fluid. The analog
recorder output may be continuously used in conjunction
with a recorder to display and record the pH measure-
ments.
Baroid's pH Meter is designed with all solid-state cir-
cuitry for field reliability and research laboratory accu-
racy.
60006—Baroid Lab Model Digital pH Meter, complete with combination
pH probe, soaker bottle with soaker solution, АТС probe and
comprehensive instruction manual

No. 60006—Lab Model Digital pH Meter


60040—POCKET pH METER
The Pocket pH Meter provides a practical alternative to
pH Litmus paper. This easy-to-use instrument does the
work of hundreds of rolls of indicator paper. With a resolu-
tion of 0.1 pH and accuracy of ± 0.2 pH, the Pocket pH
Meter is just as reliable as many laboratory models. State-
of-the-art electronics and an easy-to-read digital display
make this pH Meter the ideal portable meter.

60040—Pocket pH Meter, range 0 to 14 pH, battery included

60010—DIGITAL pH METER
The Digital pH Meter is easy to operate, rugged, portable,
and compact, measuring only 3" by 6". It is battery oper-
ated and has a 5/16" high LCD display that is easy to read
in all lighting conditions. The meter is packaged in a
rugged carrying case with one 9-volt alkaline battery, per-
manently sealed combination probe, pH 4, 7 and 10 buffer
capsules, plastic buffer bottles and a comprehensive
No. 60040—Pocket pH Meter manual.
Each Digital pH Meter is inspected and tested to
ensure reliable and trouble free operation. It is accurate
and repeatable to ± .02 pH and has solid state integrated
circuitry with temperature stable components. The meter
includes a standardizing knob for calibration and slope
control that matches the meter to the probe for optimum
accuracy.
The meter operates with a range of 0 to 14 pH and has
a complete line of accessories. With its low battery indi-
cator, optional 115-volt and 230-volt AC adapters, and
optional car adapter, the Digital pH Meter is ready for field
and lab operation.
60010—Digital pH Meter with case, combination probe, one 9-volt alka-
line battery, buffer capsules and buffer bottles

No. 60010—Digital pH Meter

20
Accessories pH INDICATORS
60003—АТС Probe When extreme accuracy of pH measurement is not
60005—Soaker Solution, 8 oz
60004—pH Probe Soaker Bottle w/Solution, 2 oz
required, simple colorimetric indicators will suffice.
60012—AC Adapter 115 VAC 50-60Hz Changes in color or color intensity over the range of each
60013—AC Adapter 230 VAC 50-60Hz indicator should be sufficient to allow the operator to read
60014—Baroid pH Tester to within 0.5 pH unit.
60016—Baroid Static Probe Holder
60017—Baroid Dynamic Probe Holder
60018—Baroid Buffer Capsules Package pH Indicator Units and Parts
60019—Baroid pH Meter Car Adapter 62301—Baroid High pH Indicator Solution, 8 oz
60825—"AA" 1.5 volt Alkaline Battery 62400—Wide Range Hydrion pH Dispenser with 1 roll Hydrion
50434—Demineralizer Wash Bottle, 250 ml Paper A, pH 2-10, and 1 roll Hydrion Paper B, pH 1-11
52717—Distilled Water, 1 gal 62401—Hydrion A Refill, pH 2, 4, 6, 8, 10, box of 5 rolls
52715—Distilled Water, 1 qt 62402—Hydrion В Refill, pH 1, 3, 5, 7, 9, 11, box of 5 rolls
60301—Buffer Solution, pH 7.0,1 oz 62500—Short Range Hydrion pH Dispenser with 1 roll of Hydrion
60302—Buffer Solution, pH 10.0, 1 oz Paper, pH 6-8, and 1 roll of Hydrion Paper, pH 8-9.5
60303—Buffer Solution, pH 4.0,1 oz 62501—Hydrion Refill, pH 6-8, box of 5 rolls
60501 —Buffer Solution, pH 7.0, 8 oz 62502—Hydrion Refill, pH 8-9.5, box of 5 rolls
60502—Buffer Solution, pH 10.0, 8 oz 62503—Hydrion Refill, pH 6-11, box of 5 rolls
60503—Buffer Solution, pH 4.0, 8 oz 62600—Short Range Hydrion pH Dispenser with 1 roll of Hydrion
60300—Buffer Solution, pH 7.0,16 oz Paper, pH 10-12, and 1 roll of Hydrion Paper, pH 12.5-14
60400—Buffer Solution, pH 10.0,16 oz 62601—Hydrion Refill, pH 10-12, box of 5 rolls
60101 —Vial, 15 x 50 mm, 10 ml 62602—Hydrion Refill, pH 12.5-14, box of 5 rolls
60105—Beaker, 50 ml, Pyrex 62603—Hydrion Refill, pH 9-12, box of 5 rolls
60630—Combination Probe 83122—Color pHast Indicator Sticks, range 0-14, box of 100
L4409—Battery, 9 volt 83121—Color pHast Indicator Sticks, range 7.5-14, box of 100
60900—Potassium Chloride Solution, saturated, 4 oz bottle
60041—Battery, 1.4-volt, f/Pocket pH Meter

pH INDICATORS
Each Color pHast® Indicator Stick has four
colored squares for testing the full pH range
(0-14) with a sensitivity of 0.5 pH.

No. 83122—Color pHast® pH Indicator Stick

Probe Holders, AC and 12-volt Adapters, and pH Tester

Hydrion pH Dispensers

21
API FILTRATION TESTING EQUIPMENT
The Baroid Low Pressure Filter Press is the most Complete Unit Assemblies
effective means of determining the filtration properties 30000—Filter Press, single, basic unit with extra set of No. 32600
neoprene gaskets
of drilling muds and cement slurries. All Baroid API 30002—Filter press with stainless steel cell, otherwise same as No.
Filter Press Assemblies consist of a mud reservoir 30000
mounted in a frame, a pressure source, a filtering 30004—Stainless steel cell assembly
medium and a graduated cylinder for receiving and 30100—Filter Press includes:
measuring filtrate. 30000—Filter Press
31700—Air Hose, 3ft
Baroid has available the No. 32801, 28 x 500 mesh N3000—Graduated Cylinder, 25 ml
stainless steel filter cloth screen and the No. 32802, N8700—Filter Paper 3-1/2" (9 cm) box of 100
325 mesh with 60 mesh back-up stainless steel 30101—Filter Press includes:
screen for use in testing cement slurries as recom- 30000—Filter Press
31700—Air Hose
mended in API Code RP 10B. 33700—Regulator
The Baroid Filter Press units are constructed of 34400—Bleeder Valve
anodized aluminum, stainless steel and chrome plated N3000—Graduate
brass. Working pressure is 100 psi and the filtering N8700—Filter Paper 3-1/2" (9 cm) box of 100
area is 7.1-in2. L1113—13-1/4" x 2-1/2" NPT Brass Pipe Nipple
30200—Filter Press assembly includes:
The Dead-Weight Hydraulic Assembly No. 33500 30000—Filter Press
provides a source of constant hydraulic pressure in 31700—Air Hose, 3ft
one compact unit. It consists of a water reservoir, pis- 34005—Nitrogen Cylinder
ton and cylinder, dead weight, delivery pressure 34265—Regulator
34400—Baroid Safety Bleeder Valve
gauge, two check valves and a bleed off valve. When N3000—Graduated Cylinder, 25 ml
attached to a standard No. 30000 Baroid Filter Press it N8700—Filter Paper 3-1/2" (9 cm) box of 100
delivers 100 psi pressure to the filter cell as prescribed 30201—Filter Press includes:
in API Code RP 13B. 30000—Filter Press
A compact version of the standard Baroid Filter 33800—CO2 Pressuring Assembly
N3000—Graduated Cylinder, 25 ml
Press is also available. The No. 30205 employs one- N8700—Filter Paper 3-1/2" (9 cm) box of 100
half size filtration area. Time and pressure require- 30300—Filter Press Hydraulic Dead-Weight Assembly
ments are the same as for large units. Readings are 30000—Filter Press
converted to standard measure by multiplying by two. 33500—Dead Weight Hydraulic Assembly
N3000—Graduated Cylinder, 25 ml
N8700—Filter Paper 3-1/2" (9 cm) box of 100

No. 30000—Filter Press No. 30201 —Filter Press No. 30300—


Basic Unit CO, Pressurized Dead Weight
Hydraulic Filter Press

22
30600—Filter Press, Wall Mount, complete with mounting bracket and 30502—Filter Press Assembly utilizing CO2 cartridges in stainless steel
extra set of 3 No. 32600 neoprene gaskets carrying case.
30800—Filter Press Kit includes: 30600—Filter Press, Wall Mount
30600—Filter Press, Wall Mount 32800—Screen, Monel metal
33800—CO2 Pressuring Assembly 33800—CO2 Pressuring Assembly
N3000—Graduated Cylinder, 25-ml 36401—Carrying Case, stainless steel
N8700—Baroid Filter Paper (pkg of 100) N3000—Cylinder, Graduated, 25-ml
N3100—Cylinder, Graduated, 10-ml
N7700—Timer, Interval, 30-minute
N8700—Baroid Filter Paper (pkg of 100), 2 supplied

No. 30502—Filter Press


with CO2 Pressuring
Assembly in Stainless
Steel Case
No. 30800—Filter Press Kit

MULTIPLE UNIT FILTER PRESSES


33500—Baroid Dead-Weight Hydraulic Assembly, with dead weight, Multiple Unit Filter Press Assemblies permit simultaneous
piston, gauge, and necessary valves and hose for connec- running of one to six filtration tests. Each of the assem-
tion to any low pressure filter press blies consists of a frame with the indicated number of
complete filter cells. Manifolds are complete with air
hoses, cut-offs, and bleeder valves, but do not include
pressure regulator and hoses; such as, No. 34265 and
No. 31800 for connection to compressed air or nitrogen
systems.

Complete Multiple Units


31100—Six-Unit Filter Press complete with manifold
31300—Four-Unit Filter Press complete with manifold

Other multiple units available upon request.

No. 33500—Dead Weight


Hydraulic Assembly

No. 31100—Six Unit Filter Press

23
30205—Half Area Filter Press Assembly includes: Parts for Baroid Low Pressure Filter Press Units
30208—Rubber-Diaphragm (sample boot) L4500—О Ring for '/2-in. area Filter Press Bleeder Valve
33601—CO2 Cartridges (box of 10) L4502—0 Ring for 1/2-in. area Filter Pipette Seal
37601—Wall Mounting Bracket L4983—С Ring for '/2-area Filter Press Bleeder Valve
N3100—Graduated Cylinder, 100-ml L4984—E Ring for Уг-агеа Filter Press Base Cap
N6100—Pipette, 10-ml 30208—Diaphragm and Gasket for Уг-агеа Filter Press
N8800—Baroid Filter Paper, 21/Hn. dia. (pkg of 100) 30209—Screen for V2-area Filter Press
L4500—О Ring for Bleeder Valve 31700—Air Hose, 3-ft, with connectors
L4502—О Ring for Pipette Seal 31800—Air Hose, 6-ft, with connectors
L4983—С Ring for Bleeder Valve 31900—Base Cap with Filtrate Tube
L4984—E Ring for Base Cap 32000—Filtrate Tube
32101 —1/4-in. NPTx Vt -in. Air Hose Adapter
32110—Top Cap
32200—Cell Cylinder
32305—Frame, Bench Mounting, one piece (bare frame without Т
screw, graduate support or threaded insert)
32600—Neoprene Filter Press Gasket, 31/2-in. OD x 3-in. ID x 3/32-in.
Thick
32700—Support Rod
32800—Screen, Monel metal, 60-mesh
32801—Screen, stainless steel, for testing cement, 28 x 500-mesh filter
cloth
32802—Screen, stainless steel, for testing cement, 325-mesh with 60-
mesh back-up
32900—Thumb Screw
33000—Т screw, stainless steel
33100—Support for Graduated Cylinder
33104—Support for Graduated Cylinder, clip-type
33514—Air Hose, 12-in.
37001—Frame Wall Mounting, complete (Order No. 37601 Wall Bracket
for slip-mounting this frame to wall).
37100—Insert, threaded, for one-piece frames No. 32305 and No. 37001
37400—Speed Coupler for air line
37500—Speed Connector for Coupler
37600—Frog Bracket for Frame No. 37001
37601—Wall Bracket for Frame No. 37001
No. 30205—Half Area Filter Press N8700—Filter Paper, ЗУНп. Special Hardened, box of 100

Parts for No. 33500 Dead-Weight Hydraulic Assembly


L4510—О Ring for Dead-Weight Hydraulic Assembly Piston
33509—Check Valve
33512—Pressure Gauge, 0 to 200 psi, 1 Win. diameter
33514—Air Hose with connectors, 12-in.
33515—Cap for Water Reservoir
CO PRESSURING ASSEMBLIES Parts for CO2 Pressuring Assemblies
For convenience in size and weight, Baroid has developed L3706—0 to 200 psi Gauge, 1 Уг-in. diameter, Win. NPT, back-
a C02 Pressuring Assembly for use on any of the low pres- connected, chrome-plated
sure filter presses. This assembly utilizes midget C02 33512—0 to 200 psi Gauge, 1 Win. diameter, Win. NPT bottom-
Cartridges that are punctured inside a chamber that connected, chrome-plated
allows the CO2 to flow through a regulator into the filter 33601—CO2 Cartridge (pkg of 10)
33601—Puncturing Pin for CO2 Cart ridge
press cell. 33605—Gasket for CO2 Cartridge
33606—Barrel for СОг Cartridge Chamber
Complete Units 33610—Adapter (for connecting external air supply in place of CO2
33800—CO2 Pressuring Assembly for attaching to standard filter cartridges)
presses. Includes following spare parts: 33620—CO2 Adapter Head
33601 —CO2 Cartridges (box of 10) 33700—Airco Pressure Regulator, C02
33801 —CO Assembly with top cap. 33720—Filter, Felt, for preventing mud from entering regulator
34400—Safety Bleeder Valve (170-psi pop-off)
33770—Regulator Repair Kit
33704—Replacement Diaphragm

No. 33801 —
CO2 Assembly
with Top Cap

24
FANN MODEL 12B FILTER PRESS MODEL MB FILTER PRESS
The FANN Model 12B Filter Press consists of a stain- The Model MB Filter Press is a field portable instru-
less steel cell assembly with an integral grid place ment and consists of an aluminum cell with a stainless
assembly to support the filter paper, CO2 cartridge steel screen to support the filter paper, CO2 cartridge
pressure source, pressure regulator and gauge, all pressure source, pressure regulator and gauge.
mounted on a telescoping support.

No. 30500—FANN Model 12B


Filter Press

30500—FANN Model 12B Filter Press, Single Cell


30501—Complete Cell Assembly, Type 12B
30159—Regulator
34252—Pressure Gauge, 0 to 200 psi Model MB
33601—CO2 Cartridges, box of 10 Filter Press with Optional Case
N3000—Graduated Cylinder, glass, 25 ml
N8700—Filter Paper 3-1/2" (9 cm) box of 100 10652—Model MB Filter Press
Instrument size: 12.5" x 5.5" x 7" (320 x 140 x 180 mm) 10869—Complete Cell Assembly, aluminum cell with stainless
Instrument weight: 7.5 Ib (3.4 kg) steel screen
10634—Regulator
Optional accessory: 33512—Pressure Gauge, 0 to 200 psi
30840—Case, Molded Plastic 13500—CO2 Cartridge Holder Assembly
33601—CO2 Cartridges, box of 10
FANN MODEL 12BL FILTER PRESS N3000—Graduated Cylinder, glass, 25 ml
The Model 12BL can be used with 2, 4 or 6 cell units N8700—Filter Paper 3-1/2" (9 cm), box of 100
and each cell may be operated independently of the L4026—Stopcock Grease, 50 grams
31377—O-Ring, 568-234 NIT, 2 supplied
others by means of a dual purpose valve at each sta- L4506—O-Ring, 568-011 NIT, 3 supplied
tion. When the needle valve is completely closed, it L4505—O-Ring, 568-010 NIT, 3 supplied
automatically bleeds the cell of pressure and shuts it Instrument size: 11" x 8" x 6.5" (279 x 203 x 159 mm)
off completely from the manifold. Instrument weight: 14 Ib (6.4 kg)
10674—Model MB Filter Press in stainless steel case
30514—FANN Model 12BL-2 Filter Press, 2 cell
Instrument size: 15" x 12.1" x 5" (390 x 307 x 127 mm)
Instrument weight: 10 Ib (4.5 kg)

30508—FANN Model 12BL-4 Filter Press, 4 cell


Instrument size: 15.5" x 22.1" x 5" (390 x 561 x 127 mm)
Instrument weight: 12 Ib (5.5 kg)

30506—FANN Model 12BL-6 Filter Press, 6 cell


Instrument size: 15.5" x 32.1" x 5" (394 x 815 x 127 mm)
Instrument weight: 14 Ib (6.3 kg)

Each model 12BL Filter Press unit includes the following accessories:
30501—Complete Cell Assembly, type 12B
L3706—Pressure Gauge, 0 to 200 psi
31611—Wrench, Hex Key, 1/8"
N3000—Graduated Cylinder, glass, 25 ml No. 30506—FANN Model 12BL-6
N8700—Filter Paper 3-1/2" (9 cm) box of 100 Filter Press
25
BAROID HIGH-PRESSURE HIGH-TEMPERATURE FILTER PRESSES FOR
TESTING FILTRATION PROPERTIES OF DRILLING MUD, CEMENT SLURRIES,
FRACTURING FLUIDS
High-Pressure, High-Temperature (HPHT) Filter For temperature control on all HPHT Filter Presses,
Presses are an efficient means of evaluating the filtra- the cell sits in a thermostated aluminum well for heat-
tion properties of drilling muds at high temperature ing and filtration. The heating chamber completely
and pressures. The cells have a filtering area of 3.5 in2 encloses the filtering area, assuring filtration at the
and can be operated at pressures up to 900 psi with desired temperature. Power consumption of the stan-
the compact, easily attached CO2 pressuring unit pro- dard size (175-ml) unit is only 400-watts. The 500-ml
vided. Standard nitrogen manifolds are available for filter press requires 800-watts.
operating to higher pressures as required, 1200 psi on The standard cell of these filter presses is made of
the cell and 750 psi on the receiver, with the No. stainless steel. The cells have valves at top and bot-
38411 regulator, or to bottle pressure with special reg- tom so that they can be closed in for heat-up and cool-
ulators. These units may be operated up to 200°F down. This design also makes it possible to use the
using a graduated cylinder to collect filtrate. However, cell for aging and agitation in the Baroid Roller Oven
for temperatures above 200°F the appropriate back- before filtration properties of the same are determined.
pressure receiver must be used to prevent evapora- The smaller units operate up
tion of the filtrate. The standard 38720 Back Pressure to 350°F. The larger units
Receiver has a separate can be operated up to
CO2 pressuring source slightly above SOOT. For
and back pressures operation above 400°F, the
up to 150 psi can paper filter should be
be placed on the backed up with a glass fiber
receiver to obtain filter, No. N8802, or stain-
the desired dif- less steel filter, No. N8804.
ferential across
the filtration area.
If an ion analysis is to
be made of the filtrate, nitrogen
should be used for the back pres-
sure. The nitrogen manifolds are
provided with safety relief valves.

No. 38770—500 ml HPHT Filter Press No. 38700—260 ml HPHT Filter Press

38770—HPHT Filter Press, 500 ml, 2500 psi Cell, for tests involving fluid 38700—HPHT Filter Press, 175 ml, 2500 psi Cell, for tests up to 350° F
volumes to 400 ml and temperatures up to 500°F, complete with with CO2 Pressurizing assembly and 15 ml (CO2) Back-Pressure
Dual Nitrogen Manifold and 100 ml Back-Pressure Receiver, 115 Receiver, 115 Volts, 400 Watts
Volts, 800 Watts 38740—HPHT Filter Press, 175 ml, 2500 psi Cell, for tests up to 350°F,
38771 —HPHT Filter Press, 500 ml, 2500 psi Cell, for tests involving fluid with CO2 Pressurizing assembly and 15 ml (СОг) Back-Pressure
volumes to 400 ml and temperatures up to 500°F, complete with Receiver, 230 Volts, 400 Watts
Dual Nitrogen Manifold and 100 ml Back-Pressure Receiver, 230 38742—HPHT Filter Press, 175 ml, 2500 psi, Double Ended Cell, for
Volts, 800 Watts tests up to 350° F with C02 Pressurizing assembly and 15 ml
38780—HPHT Filter Press, 500 ml, 2500 psi Double Ended Cell, for tests (CO2) Back-Pressure Receiver, 230 Volts, 400 Watts
involving fluid volumes to 400 ml and temperatures up to 500° F, 38748—HPHT Filter Press, 175 ml, 2500 psi, Double Ended Cell, for
complete with Dual Nitrogen Manifold and 100 ml Back- tests up to 350° F with Dual Nitrogen Manifold for Primary and
Pressure Receiver, 115 Volts, 800 Watts 15ml Back-Pressure Receiver, 115 Volts, 400 Watts
38781 —HPHT Filter Press, 500 ml, 2500 psi Double Ended Cell, for tests 38749—HPHT Filter Press, 175 ml, 2500 psi, Double Ended Cell, for
involving fluid volumes to 400 ml and temperatures up to 500° F tests up to 350° F with Dual Nitrogen Manifold for Primary and
complete with Dual Nitrogen Manifold and 100 ml Back- 15 ml Back-Pressure Receiver, 230 Volts, 400 Watts
Pressure Receiver, 230 Volts, 800 Watts
Each 175 ml HPHT Filter Press is furnished with the following oper-
Each 500 ml HPHT Filter Press is furnished with the following operating ating supplies:
supplies: L4503—"O" Rings for Valve Stem, 12 supplied
L4503—"O" Rings for Valve Stem, 24 supplied L4606—"O" Rings for Cell and Cell Cap, 4 supplied
L4606—"O" Rings for Cell and Cell Cap, 24 supplied N3000—Graduated Cylinder, 25 ml
L4676—"O" Rings for Back-Pressure Receiver, 6 supplied N7901—Thermometer, 50-350°F, Metal Dial, 5" Stem
N3000—Graduated Cylinder, 25 ml N8800—Filter Paper, 2-1/2", Special Hardened, box of 100
N7902—Thermometer, 50-500°F, Metal Dial, 8" Stem
33601—CO2 Cartridge, box of 10, 4 supplied
N8800—Filter Paper, 21/2-in., Special Hardened, box of 100
34600—Wrench, 6", adjustable
N8804—Filter, DynalloyXS
38702—Instruction Book
34600—Wrench, 6-in., adjustable
38709—Set Screw Wrench, 5/16"
38709—Set Screw Wrench, 5/16
38718—Cell Cap Locking Screws, 2 supplied
38718—Cell Cap Locking Screws, 2 supplied
38772—Instruction Book

26
Accessories and Parts for HPHT Filter Presses Cell Caps
N3000—Graduated Cylinder, 25 ml 38712—Cell Cap, 1500 psi, with 60-mesh Screen
N7901—Thermometer, 50-350° F Metal Dial 38716—Cell Cap, 1500 psi, for detachable Screens
L4503—"O" Ring for Valve Stem 38752—Cell Cap, 2500 psi, with 60-mesh Screen
L4513—"O" Ring for 15 ml Receiver 38756—Cell Cap, 2500 psi, for detachable Screens
L4606—"O" Ring for Cell and Cell Cap 38757—Cell Cap, 2500 psi, for Aloxite Disc
L4676—"O" Ring for 100 ml Receiver
33601—CO2 Cartridges, box of 10 Screens and Filters
38418—Gland, Standard, forCGA590 Nitrogen Fitting 30209—60-mesh Screen, for Caps No. 38712 and No. 38752
34400—Safety Bleeder Valve (170 psi pop-off) 38753—28 x 500 Stainless Dutch Twill, detachable Screen
34600—Wrench, 6-in., adjustable 38754—325-mesh with 60-mesh back-up, detachable Screen, for
34900— Vt -in. x 1/4 -in. NPT Male Needle Valve Cement Testing
35300—1/e-in. x Ув-in. NPT Male Needle Valve N8800—Filter Paper, 2 Win., Special Hardened, box of 100 sheets
38708—Heating Jacket with accessories, 115-Volt, 400-Watt N8802—Glass Fiber back-up, 2УНп., box of 50 sheets
38709—Set Screw Wrench, 5/16 N8804—Stainless Steel Filter, Dynalloy X-5, 2V2-in.
38713—Valve Stem for HPHT Cell N8900—Aloxite Disc Filter
38714—Cell Removal/Carrying Tool
38717—Valve Seat Resurfacing Tool
38718—Locking Cap Screw for HPHT Cell Pressurization Equipment for HPHT Filter Presses
38719—Back-Pressure Receiver, for use with Nitrogen Manifold 38411—Regulator with 1500 psi gauge
38720—Back-Pressure Receiver, 15-ml, forCO., Pressure 38412—CO2 Pressuring Unit with Manifold
38721—Collection Tube only, for Back-Pressure Receiver, 15-ml 34005—Air Cylinder, seamless steel, 4-in. diameter x 17-in. with Kerotest
38723—Heating Jacket with accessories, 230-Volt, 400-Watt valve and pressed steel valve protector, filled with nitrogen (See
38726—Carrying Case, stainless steel, for HPHT Filter Presses note below)
38732—Retainer Pin, Long, for 100-ml Receiver 34265—Regulator, Nitrogen, with high and low pressure gauges (See
38734—Retainer Pin, Short, for HPHT Filter Press note below)

Nitrogen Manifolds for HPHT Filter Presses


38765—Manifold for connecting HPHT Press to nitrogen source at 1200 WARNING:
psi and 750 psi (for 2 cells, or 1 cell and 1 back-pressure
receiver)
38766—Manifold for connecting HPHT Press to nitrogen source at 1350
psi and 170 psi (for 2 cells, or 1 cell and 1 back-pressure
DO NOT USE COMPRESSED OXYGEN
receiver) AS A GAS SOURCE
38767—Manifold for connecting HPHT Press to nitrogen source for 1
cell, 1350 psi, max
38768—Manifold, 4-unit, for use with No. 38765 or No. 38766 for oper- All fittings on nitrogen cylinders and regulators sup-
ating 4 HPHT Filter Presses and Receivers on 1 nitrogen source plied by Baroid Testing Equipment are furnished with a
CGA580 fitting. Where other fittings are required,
Core Holding Equipment for HPHT Filter Presses please specify with the order.
38735—Core Seal Ring for 1 -3/4" diameter core
38736—Core Seal Ring for 1" diameter core
38737—Core Support, adjustable length
38738—Core Spacer Ring, adjustable length
38739—Core Spacer required for 500 ml Cells

Cell Assemblies for HPHT Filter Presses


38750—Cell, 175 ml, 2500 psi, Double Ended with 2 end caps No.
38756 and 2 screens No. 38754
38751—Cell, 175 ml, 2500 psi, Single Ended with end cap No.
38756 and screen No. 38754
38758—Cell, 175 ml, 250 psi, Single Ended with end cap No. 38752
and 60-mesh screen No. 30209
38764—Cell, 500 ml, 2500 psi, Single Ended with end cap No.
38752 and 60-mesh screen No. 30209
38773—Cell, 500 ml, 2500 psi, Double Ended with 2 end caps No.
38756 and 2 screens No. 38754
38782—Cell, 500 ml, 2500 psi, Double Ended with one end cap No.
38756 and screen No. 38754, and one end cap No. 38757
and Aloxite Filter Disc No. N8900 No. 38750—
38784—Cell, 175 mi, 2500 psi, Single Ended with end cap No. Double Ended Cell
38757 and Aloxite Filter Disc N8900

NOTE: Any combination of cells and pressuring configura-


tions can be accomplished by ordering individual
components.

27
J
FANN HIGH TEMPERATURE-HIGH 38225—PERMEABILITY PLUGGING
PRESSURE FILTER PRESS, MODEL HTHP APPARATUS
The FANN High Temperature-High Pressure Filter The Permeability Plugging Apparatus (PPA) is
Press has been developed for evaluating the filtration designed to provide accurate simulation and measure-
properties of drilling fluids at elevated temperatures ment of downhole static filtration. The PPA is very use-
and pressures. Filtration tests are usually conducted at ful in predicting how a drilling fluid can form a
a sample temperature of 300°F (149°C) and 50 psi permeable filter cake to seal off depleted/under pres-
(3450 kPa) differential pressures with the standard sure intervals. The PPA utilizes a conventional HTHP
CO2 pressuring unit. Filtering area of the test cell is a Heating Jacket to simulate reservoir temperature. The
standard 3.55 square inches (22.9 cm2). When testing fluid cell is inverted with pressure applied from the bot-
above 200°F (93°C) the back pressure receiver tom of the cell and filtrate collected out the top.
assembly is attached to the filtrate outlet to prevent Pressure is transferred to the mud by a small hydraulic
evaporation of the filtrate. Back pressures up to 150 hand pump through a small floating piston within the
psi (1035 kPa) can be provided through the receiver by cell. The PPA employs an aluminum oxide (aloxite)
the assembly's own pressure source. A safety pop-off filter disk, which is available in varying porosities. This
valve releases receiver pressure if it should exceed disk offers a more authentic representation of the
160psi(1100kPa). actual filter cake which develops on the wall of the
formation.
Specifications
• 2500 psi working pressure
• 500°F maximum temperature
• 120/240 volts 50/60 Hz
• Sample volume 450 ml
• Power required 800 watts

No. 10777—FANN HPHT Filter Press

10777—FANN High Temperature Filter Press, Model HTHP, 110 volts


35173—FANN High Temperature Filter Press, Model HTHP, 230 volts
10789—Cell Assembly with cell body and cell lid, 80-mesh stain-
less steel screen
10838—High Pressure Regulator Assembly with regulator, pres-
sure gauge 0 to 2000 psi, pressure gauge 0 to 1000 psi
and CO2 cartridge holder assembly
10801—Receiver Assembly with regulator, pressure gauge 0 to No. 38225—Permeability Plugging Apparatus
200 psi, CO2 cartridge holder assembly, receiver
10798—O-Ring for High Temperature Filter Cell 568-141 VUT
N8800—Filter Paper, 2-1/2", box of 100 circles
10810—Thermometer, Metal Stem 4", 50 to 500°F 38225—Permeability Plugging Apparatus
33601—CO2 Cartridges, box of 10 INCLUDES:
N3000—Graduated Cylinder, glass, 25 ml 33601—CO2 Cartridges, box of 10
L4026—Stopcock Grease, 50 grams 38226—Heating Jacket 115 volts
11541—Hex Wrench, 1/4" 38233—Piston Removal Tool
Optional Accessories: 38234—Back Pressure Receiver Assembly
11024—Stainless Steel Case 38238—High Pressure Cell Assembly
N7902—Thermometer, Metal Stem, 8", 50 to 500°F 38239—Hydraulic Pump Assembly
Instrument size: 28" x 9" x 7" (711 x 229 x 178 mm) 38412—Pressuring Device CO2
Instrument weight: 34 Ib (15.4 kg) N7902—Thermometer Dial 0-500°F 8" Stem
N8900—Filter Aloxite Disc Grade 2, 10 each
Optional Accessories:
N8901—Filter Aloxite Disc Grade R15
N8902—Filter Aloxite Disc Rl 70 Grade 10
38220—Stainless Steel Case

28
36312—FANN MODEL 90 DYNAMIC FILTRATION SYSTEM
The FANN Model 90 Dynamic Filtration System is the The LCD display allows monitoring of real-time test
industry's first truly dynamic filtration system for con- results, which are printed for further analysis and filing
ducting filter cake formation and permeability analysis of test results. The Model 90 also features an interface
for drilling fluids optimization. The Model 90 can be port which allows downloading of ASCII-formatted
heated and pressurized to provide the closest possible data.
simulation of downhole conditions. The filter medium is Safety Features
a thick-walled cylinder with rock-like characteristics to • Rupture disk on high pressure gas supply
• Safety pressure relief valve
simulate the build-up of filter cake on the formation. • Independent over-temperature shutdown
The filter medium is available in varying porosities and • Heater and motor cut-off interlock
permeabilities. Filtration occurs radially from the inside • Automatic cool-down upon completion of test
of the filter core to the outside. At the same time, the • Cell design uses no stressed threaded closures
filter cake is formed on the inside of the filter core to • Cell constructed of Monel K500 with stainless steel end caps
Specifications
simulate filter cake formation on the wall of a borehole. Working pressure: 2500 psi
A polished stainless steel shear bob runs through the Maximum temperature: 500°F
central axis of the filter core. The shear bob is rotated Maximum differential pressure: 500+ psi (actual maximum limited by
to produce a concentric cylinder-type shear across the core strength)
Maximum power requirements: 1500 watts
filtration surface. The Model 90 is fully automatic with a Heater power: 1200 watts
built-in computer controller. Through menu-driven soft- Power supply: 120/240V, 50/60 Hz
ware, the user can establish up to 20 sequence steps Sample volume: 250 cc
to program the following testing parameters: . Filtrate volume: 50 cc
• Temperature Shear bob drive: 1/4 hp motor with belted magnetic drive
Shear rate constant: .2693 1/s per rpm (no filter cake)
• Pressure Initial shear rate range (with standard bob): 9, to 269 1/s
• Differential pressure
• Shear rate. Instrument size: 12.5" x 17.75" x 28" (305 x 455 x 711 mm)
Instrument weight: 170 Ib (77 kg)

йшоЬшошп

29
MODEL 391, BRIDGING MATERIALS TESTER 21150—DIFFERENTIAL STICKING TESTER
The Baroid Differential Sticking Tester Apparatus was
The ability of a material to seal a lost circulation zone is designed to determine "Stuck Pipe Tendency" and
important in the determination of the proper material to effectiveness of spotting fluids in any given drilling
use. The Baroid Bridging Materials Tester is designed to fluid. The Stuck Pipe Tendency Coefficient is read
aid in the evaluation of materials used for regaining circu- directly at the conclusion of the test. By measuring the
lation. area of caking during a test, a bulk sticking coefficient
The Bridging Materials Tester effectively simulates is obtained; and by using a yoke accessory, the stick-
various formations by using a series of slotted discs, ing coefficient of a controlled cake thickness can be
screens, B.B. shot or marble beads. Fluid containing lost measured. The question of how likely a given fluid will
circulation materials is applied under 1,000 psig pressure produce a "stuck" situation and the effectiveness of a
to this simulated formation. The efficiency of the seal given treatment can be investigated onsite.
formed and the volume of fluid lost before a seal is formed The unit is pressurized by the CO2 assembly or any
is easily determined. Test results indicate the particle size nitrogen source. The standard test uses 477 psi differ-
and distribution of the bridging materials required for ential pressure applied to a stainless steel vessel of
sealing the zone in order to regain circulation. approximately 140 ml capacity. Measurements can be
Size: 32" x 14" Diameter (812.8 x 355 mm) made on either a flat-faced torque plate or a plate of
Weight: 200 Ib (90.7 kg) 12-1/2" radius. (Both are provided.) In the event of a
"sticky" sample that tends to adhere more to the plate
391 oo—Bridging Materials Tester than to the filter paper, stainless steel micro-corruga-
tion disks are provided, along with extra-strength
Optional Nitrogen Pressurizing Equipment: paper to ensure success of the test.
34005—Nitrogen Cylinder
34265—Regulator
38420—High Pressure Hose 21150—Differential Sticking Tester
INCLUDES:
38412—CO2 Pressurizing Assembly
21154—Locking Mesh Disk
L4330—Spanner Wrench
L4325—Torque Wrench
N8805—Extra Strength Filter Paper, box of 100
33601—CO2 Cartridges, box of 10

Optional Equipment:
21155—Position Yoke
38726—Stainless Steel Carrying Case

No. 21150—Differential
Sticking Tester

No. 39100—Bridging Materials Tester

30
No. 35712—FANN Model 23D No. 21200—EP/Lubricity Tester

MODEL 23D, FANN ELECTRICAL STABILITY 21200—BAROID COMBINATION


TESTER EP (EXTREME PRESSURE) AND
The FANN Model 23D Electrical Stability Tester is an LUBRICITY TESTER
accurate, compact and portable instrument which mea- The Baroid Combination EP (Extreme Pressure) and
sures the relative electrical strength of emulsions having Lubricity Tester is used to: (1) measure the lubricating
a continuous oil phase. It is a self-contained unit con- quality of drilling fluids, (2) provide data to evaluate the
sisting of a meter and probe, and it operates on four 9-volt type and quantity of lubricating additives that may be
batteries. required and (3) predict wear-rates of mechanical parts
The instrument features a digital readout and sinusoidal in known fluid systems. The EP tests are performed by
output waveform for greater accuracy. Pushbutton auto- applying a measured force with a torque wrench to a
matic ramping makes the unit simple to operate and pro- torque-sensitive, rotating bearing cup. This operation
vides repeatable results. Calibration resistors are supplied indicates the film strength of the fluid being tested. The
with each instrument to verify the accuracy and linearity lubricity test measures fluid resistance (lubricating char-
of the unit. The tester is contained in a watertight carry acter) between two moving hardened-steel surfaces at a
case, and fully conforms to API specification RP 13B. hundred pounds force (which translates into a 5,000 to
10,000 psi on intermediate fluids).
Case size: 9 x 7.9 x 3.5 Inch (22.9 x 20.1 x 8.9 mm)
Weight: 4 Ibs (1.8 kg) 21200—Baroid EP and Lubricity Tester, 115-volt, 50 or 60-Hz
INCLUDES:
21010—EP Test Ring
35712—FANN Model 23D Electrical Stability Tester 21012—EP Test Block
INCLUDES:
21030—Lubricity Test Ring
33291—Probe and cable 21032—Lubricity Test Block
L4409—Battery, 9-volt L4320—Torque Wrench
B1011—Carrying Case 20220—Sample Cup, Stainless Steel
35721—Calibration resistor (high range) L4302—Flare Wrench
35722—Calibration resistor (low range)
Optional:
Optional Equipment: L5819—Transformer for 230-volt operation
35720—Calibration Standard Set 21034—Calibrated Ring/Block Pair
35719—Battery Eliminator (AC Adaptor), 115-volt
35731—Battery Eliminator, 230-volt
N7900—Thermometer

31
Retorts for Liquid and Solid Analysis
A retort, sometimes also known as a still, is used to deter- Parts for Baroid Oil and Water Retort Kits
mine the quantity of liquids and solids in a drilling fluid. A 87004—Spatula
carefully measured sample of mud is placed in a retort 87008—Retort, 10 ml capacity, complete
87009—High Temperature Lubricant for retort threads
cup and heated until the liquid components have been 87011—Lid for Retort Mud Chamber
vaporized. The vapors are passed through a condenser 87013—Condenser, Aluminum
and collected in a graduated cylinder or centrifuge tube 87015—Corkscrew
which has been calibrated "TC" to contain the condensed 87016— Vi Ib Steel Wool, No. 00
87017—Pipe Cleaner, 10-ft
liquids at 20°C. The distillate is read directly as volume 52501—Wetting Agent, 1 oz
percent of the prescribed sample volume. The solids, both N1401—Brush, Test Tube
suspended plus dissolved, are determined by subtraction N3100—Graduated Cylinder, 10ml
from 100 percent of the initial sample. For fresh-water N3101—Graduated Cylinder, 5 ml
muds, the relative amounts of barite and clay can be esti- L6112—Heating Element, 100-watt, 12-volt
L6135—Heating Element, 350-watt, 115-volt
mated. Corrections must be made for salt in the calcula- L6136—Heating Element, 350-watt, 230-volt
tion for solids content. L6401—Neon Pilot Light, 115-volt
L6504—Pilot Light, 6S6,115-volt
L7114—Power Cable
87100—OIL AND WATER RETORT KIT L8262—Retort Thermostat
The Baroid Oil and Water Retort Kit affords a simple,
direct field method of determining the percent by volume FANN MINISTILL
of oil and water in samples in drilling mud or in core sam- With the FANN Ministill, heat is applied directly to the
ples of the formation. The kit has been found to be espe- sample fluid, thereby eliminating bulky insulation and
cially useful in determining the oil content of emulsion permitting balanced heat input and loss to prevent
muds. heater burnouts. Three different heater elements are
The Baroid Oil and Water Retort Kit provides faster available for different voltage requirements. The carry-
retorting without danger of overheating with consequent ing case, retort and heater are made of stainless steel
damage to the heater unit. This has been accomplished for durability and ease of maintenance.
by adding a thermostat to control a higher wattage
heating unit. By this method the retort automatically cuts
off when distillation is complete, regardless of the supply
voltage. Distillation time on normal voltages (110-120
volts) is about 15 minutes. The retort is enclosed in a
stainless steel carrying case for greater portability.
Manufactured under U.S. Patent No. 2,723,228

87ЮО—Oil & Water Thermostated Retort Kit, 10 ml, complete with all
standard equipment in stainless steel carrying case, 115-volt,
350-watt
87101—Same as No. 87100 except for 230-volt operation
87102—Oil & Water Retort Kit, 10 ml, combination 115-volt and 12-volt,
350-watt thermostat on 115-volt; 200-watt thermostat on 12-volt
87140—Oil & Water Retort Kit, 50 ml, 230-volt
87150—Oil & Water Retort Kit, 50 ml, 115-volt, 700-watt thermostat
83051 —Removable Retort for use in airplane and offshore kits. Combi-
nation 115-volt and 12-volt, 10 ml

No. 30610—FANN 20 ml Ministill

30610—FANN Ministill, 20 ml, 115/12-volt, in Stainless Steel Case


INCLUDES:
30636—Sample Cup
30637—Cover for Sample Cup
30639—Expansion Chamber Assembly
30614—Condenser Block Assembly
30630—Cord Assembly Adapter
30626—Cord Assembly Connector
30644—Heater Assembly, 12-volts
31493—Heater Assembly, 115-volts
10161—Graduated Cylinder, 20 ml, glass, calibrated 0 to 100%, 2
31378—Spatula, Hyde
31435—Bottle Brush
31436—Pipe Cleaners, 5 mm diameter
31434—Aerosol Solution, 1/2 oz (15 ml)
31433—Liquid Steel Wool, 1/2 oz (15 ml)
35482—FANN Ministill, 20 ml, 230/12-volt, in Stainless Steel Case
INCLUDES:
All items listed above, except that 230-volt heater, No. 31494,
replaces 115-volt heater.
No. 87100- Instrument size: 5h x 6w x 9d inches (127 x 152 x 229 mm)
ОМ & Water Retort Kit Instrument weight: 8 Ib (3.6 kg)

32
FANN MODEL 50 ML MUD RETORT 87523—MULTI-RETORT 50 ML
The Model 50 ML Mud Retort is used for determining The Baroid Multi-Retort can simultaneously test five
the percentage of oil, water and solids in drilling fluids separate samples of drilling fluids and/or cuttings.
when maximum precision of measurement is required. Having the ability to test five different samples under a
A larger sample size (50 ml) is used and the rate of uniform retorting temperature provides a total data con-
power input to the heater can be adjusted by means of sistency that is unavailable in other retort instruments.
a variable transformer to permit distillation of the vari-
ous components in stages, thereby minimizing bump- Features:
ing and boilover. The heaters have sufficient wattage • Digital Temperature Controller
to permit rapid testing and can be supplied for 115-volt • Accessible Cool-Down Rack
or 230-volt operation. • Overtemperature Safety Shutdown
• 5 cell x 50 ml each
• Operates from either 115 or 230-volt source

Baroid's 5-cell Multi-Retort is the most advanced instru-


ment available to determine the quantity of liquids and
solids in a drilling fluid or on cuttings.

No. 31459—FANN 50 ML Mud Retort

31459—FANN Model 50 ML Mud Retort, 115-volts, in stainless steel


case
INCLUDES:
30140—Sample Cover
30146—Cover for Sample Cup
30141—Expansion Chamber Assembly
30684 to 6—Condenser Block Assembly
30626—Cord Assembly, Connector
30648—Heater Assembly, 115-volts, 2 supplied
32858—Variac to control 115-volts power
35336—Graduated Cylinder, 50 ml, glass, 2 supplied
31378—Spatula, Hyde
31468—Bottle Brush
31436—Pipe Cleaners, 5 mm diameter
31434—Aerosol Solution, 1/2 oz (15 ml)
31433—Liquid Steel Wool, 1/2 oz (15 ml) No. 87523—Multi-Retort 50 ML
Instrument size: 12" x 8.5" x 6.3" (305 x 216 x 160 mm)
Instrument weight: 18 Ib (8.2 kg) 87523—Multi-Retort, 50 ml, 5-cell, 115/230-volt
INCLUDES:
31465—FANN Model 50 ML Mud Retort, 230-volts, in stainless steel 87525—Lifter Tool
case 87529—Fuse Link
INCLUDES: 87530—Retort Chamber, 50 ml (5)
All items listed above except that heater assembly and Variac are 87004—Spatula
230-volt 87009—High Temperature Lubricant
31469—Heater Assembly, 230-volts 87015—Corkscrew
32859—Variac to Control 230-volts power 87016—Steel Wool, 1/4 Ib
N1401—Brush
Special Receiver Tubes designed for use in retorting oil N2900—Graduated Cylinder, 50 ml (5)
muds have been developed by Baroid and approved by Instrument size: 18" x 18" x 25" (457 x 457 x 635 mm)
Instrument weight: 127 Ib (57 kg)
the API. These Receiver Tubes are graduated and can
be used with existing Retorts and Mini-Stills.
J3012—Oil Mud Retort Receiving Tube, 10 ml
J3013—Oil Mud Retort Receiving Tube, 20 ml

33
BAROID CALCIMETERS BAROID LABORATORY ROLLER OVENS
Just which compounds are responsible for scale build-up In the investigation of performance characteristics of
in drilling fluids must be determined before an effective drilling muds and the evaluation of drilling mud additives it
chemical treating program can be implemented to control is highly desirable to simulate well conditions as closely
the scale. The Baroid Calcimeters can determine if the as possible. Baroid Roller Ovens provide an excellent
scale build-up is composed of calcium carbonate, quickly method of simulating circulating conditions. Mud samples
and with a high degree of accuracy. are placed in glass jars, No. 76000 High-Temperature
Both models of the Calcimeter are suited to a differen- Aging Cells or the cells of No. 38700 High-Pressure, High-
tial measure of the calcite to dolomite content of the Temperature Filter Presses. These are placed in the roller
unknown sample. The main difference in the two models oven, where they are subjected to moderate heat and
lies in the fact that an operator must be present during the agitation on power-driven rollers. This equipment is partic-
test with No. 43200 (Pressure Gauge Model) to record ularly useful in investigating muds where base exchange
readings at regular intervals. No. 43210 records its results reaction is of importance (such as lime-treated muds), or
on a strip chart, leaving the operator free to perform other in studying the stability of additives (such as thinners and
duties. In both models, the calcite contents are available organic colloids).
in a matter of seconds and the dolomites can be deter- Baroid Roller Ovens are well-insulated units designed
mined in 15-20 minutes. for convenient use in the field or in the laboratory. These
units can be designed to operate on 115-volt AC or DC
43200—Baroid Gauge Model Calcimeter or 230-volt AC. A thermostat permits control of tempera-
INCLUDES:
Plexiglass C02 Carbonate Cell tures between 100° and 425°F. Attention has been
Pressure Gauge (0-30 psi) given to the arrangement of gears, bearings, heating ele-
Instructions ments, etc., to provide simple maintenance. The number
43210—Baroid Recorder Model Calcimeter in stainless steel case of rollers can be varied to customer specifications. Write
INCLUDES: for details and prices on voltages other than those listed.
Plexiglass C02 Carbonate Cell
Pressure Recorder (0-15 psi)*
N0000—Portable Balance (field type) 70000—Roller Oven, 4-roll, capacity of 9 pint jars or aging cells, 115-volt
N3100—10 ml Graduate AC, 700-watts
70040—Roller Oven, same as No. 70000 except for 230-volt AC, 50
L8480—Mortar and Pestle
cycles
L4026—Lubriseal
70100—Roller Oven, 5-roll, capacity of 16 pint jars or aging cells, 115-
L8152—Graph Paper
volt AC, 1200-watts
L0640—Brush 70140—Roller Oven, same as No. 70100 except for 230-volt AC, 50
52610—% Ib Calcium Carbonate
cycles
52473—10% HCI (1 quart)
70400—Roller Oven, 150°F; capacity of 48 pint jars or aging cells, 230-
Instructions
volt AC, 3500-watts
•Special Order: 0-30 psi
70200—Roller Oven, Portable, 3-roll, capacity of 4 pint jars or aging
cells, 115-volt AC, 350-watts. Size: 12-in. wide x 22-in. long x
101/2-in. high. Net wt: 50 Ibs
70240—Baroid Portable Roller Oven, 230-volt AC, 50-60 Hz

No. 43200—
Gauge Model
Calcimeter

No. 70100—Laboratory Roller Oven

No. 43210—
Recorder Model Calcimeter

34
BAROID HIGH-TEMPERATURE
AGING CELLS
Baroid High-Temperature Aging Cells are designed for
field-testing muds at temperatures as high as 425°F.
Baroid High-Temperature Aging Cells are available
in 260 ml and 500 ml sizes to hold a sufficient volume
of mud to allow testing after aging. The 500 ml cells are
provided for greater volumes of mud to be tested at
higher temperatures with sufficient space for expansion No. 76000
as a safety factor. The cell is compact and lightweight. 260 ml Aging Cell
Non-Pressurized
Some cells include a valve and pressure connection for
prepressuring the cell before heating. This connection
to the pressure source is made in the same manner as
that used on the HPHT filter presses so that standard
nitrogen or CO2 manifolds can be used for this purpose.

76000—High-Temperature Aging Cell, 260 ml Volume, Aluminum bronze


76001 —High-Temperature Aging Cell, 260 ml Volume, Aluminum bronze
with pressurization valve
76010—High-Temperature Aging Cell, 500 ml Volume, Aluminum bronze
with pressurization valve
76012—High-Temperature Aging Cell, 500 ml Volume, 303 stainless steel
with pressurization valve
76013—High-Temperature Aging Cell, 500 ml Volume, 316 stainless steel
No. 76010
with pressurization valve
500 ml Aging Cell
76016—High-Temperature Aging Cell, 260 ml Volume, 303 stainless steel
Aluminum Bronze
76017—High-Temperature Aging Cell, 260 ml Volume, 303 stainless steel
with pressurization valve
76024—Corrosion Test Cell, 500 ml Volume, 303 stainless steel with
pressurization valve and coupon holder
76060—High-Temperature Aging Cell, 500 ml Volume, Incoloy 625, with
pressurization valve

Accessories:
L4503—O-Ring for valve stem
L4545—O-Ring for outside of cell, rubber
L4579—O-Ring for outside of cell, Teflon
L4332—Hex wrench for 3/8" set screw
76003—Hex wrench for 5/8" set screw
76007—Set screw, 3/8" for pressurized cell
76004—Set screw, 5/8" for non-pressurized cell
76002—Teflon gasket for cell lid
76005—Inner cap for pressurized cell, aluminum bronze No. 76012
76006—Outer cap for pressurized cell, aluminum bronze 500 ml Aging Cell
76008—Valve stem for pressurized cell, stainless steel Stainless Steel
76009—Inner cap for pressurized cell, stainless steel
76011—Flat washer 3/4"
76025—Glass liner for 260 ml aging cell
76026—Glass liner for 500 ml aging cell
76027—Teflon lid for glass liner
76036—Outer cap for non-pressurized aging cell
76038—Inner cap for non-pressurized aging cell, aluminum
bronze
76046—Outer cap for pressurized aging cell, 303 stainless steel
76047—Outer cap for pressurized aging cell, 316 stainless steel
76048—Inner cap for non-pressurized aging cell, 303 stainless
steel
76050—Inner cap for non-pressurized aging cell, 316 stainless steel

No. 76024
500 ml Corrosion
Test Cell

No. 70200—Portable
Roller Oven

35
83100—BRINE TEST KIT 10200—HYDROMETER KIT
The brine test kit is a portable, chemical test kit for The Baroid Hydrometer Kit includes eight specific
measuring the calcium chloride, calcium bromide and gravity hydrometers. These hydrometers measure
zinc bromide content of brines. Expensive, multiple specific gravity from 0.8 to 0.91 for diesel and 1.0 to
salt brines may now be accurately analyzed at the 2.4 specific gravity at 60°/60°F.
stockpoint or at the wellsite with this compact kit. A thermometer with a scale that ranges from -30°F
It is used to measure the weight percent of bro- to 120°F is a standard accessory to the kit. All the
mide, chloride, calcium and zinc in a brine. These val- instruments are protected in a non-corrosive, padded,
ues are used to calculate the weight percent of easy-to-carry case. Individual pieces of the kit are
calcium chloride, calcium bromide and zinc bromide available upon request and a 250 ml cylinder (made of
present in the brine. heavy glass) is offered as a convenient addition to the
The kit may also be used to test a brine qualitatively kit.
for zinc. A comprehensive procedure supplied with All the hydrometers in the kit measure to the near-
each kit provides step-by-step test instructions. est 0.002 specific gravity. They are recommended for
Formulation for all calculations is given in a simple, use in brine analyses and are designed to work in
straightforward form. conjunction with Baroid's Brine Test Kit.
Complete Unit
83100—Brine Test Kit in carrying case, 18-1/2" x 12-1/2" x 9" 10200—Hydrometer Kit to 2.4 Specific Gravity
10251—Hydrometer Cylinder
Supplies and Replacement Parts 10201 —.800 to .910 Sp. Gr. Hydrometer
11348—0.1 M EDTA Solution, 250 ml 10202—1.000 to 1.220 Sp. Gr. Hydrometer
50717—Hardness Ammonia Buffer Reagent, 100 ml 10203—1.200 to 1.420 Sp. Gr. Hydrometer
51500—Ammonium Persulfate, 100 gm 10204—1.400 to 1.620 Sp. Gr. Hydrometer
52307—Silver Nitrate, 0.141N, 250 ml 10205—1.600 to 1.820 Sp. Gr. Hydrometer
52402—Nitric Acid, 250 ml 10206—1.800 to 2.020 Sp. Gr. Hydrometer
55168—15% Sodium Hydroxide, 100 ml 10207—2.000 to 2.200 Sp. Gr. Hydrometer
64071—10% Sodium Sulfide, 100 ml 10208—2.200 to 2.400 Sp. Gr. Hydrometer
83101—Automatic Burette, 10 ml N7903—Thermometer-30° to 120°F
83102—Pipetting Safety Bulb
83105—Erlenmeyer Flask, 125 ml
83106—Volumetric Flask, 25 ml
83108—Dropper Pipette
83109—Glass Pipette, 1 ml
83110—Glass Pipette, 5 ml
83111—0.1 gram Scoop
83113—Chloride/Bromide Indicator, 50 ml
83116—Hardness Reagent #6, Vial of 100 tablets
83122—pH Indicator Strips, pkg of 100
83123—Glass Boiling Beads, 1 Ib pkg
83125—Plastic Beaker, 50 ml, Tri-Pour
83127—Zinc Qualitative Test Bottle, 25 ml

No. 10200—Hydrometer Kit

,.., --
No. 83100—Brine Test Kit

36
35225—BRINE CRYSTALLIZATION KIT 35313—PHPA POLYMER CONCENTRATION
Baroid's Brine Crystallization Kit is a field-portable unit TEST KIT
designed for measuring the crystallization tempera- The PHPA Polymer Concentration Test Kit selectively
ture of high-density oilfield brine fluids used in com- determines the concentration of PHPA (partially
pletion, workover and drilling operations. This kit hydrolyzed polyacrylamide) through a simple analytical
allows laboratory-quality temperature measurements field test utilizing a Kjeldahl procedure which was mod-
at the wellsite and measurements are easy to per- ified by Baroid. As hydrolysis of the polymer occurs,
form. The Brine Crystallization Kit provides the follow- ammonia is released and collected in boric acid.
ing data in printed format according to API standards: Subsequently, this mixture is titrated and the titration
FCTA (first crystal to appear), TCT (true crystallization end point is related to the polymer concentration of the
temperature) and LCTD (last crystal to dissolve). sample fluid.
FEATURES:
• Improves reproducibility of crystallization points
• Eliminates thermal stratification
• Provides precise and accurate temperature printouts
• Allows accurate control of cooling and heating rates

No. 35313—PHPA Polymer Concentration Test Kit

35313—PHPA Polymer Concentration Test Kit in a rugged,


lightweight plastic carrying case, 24-1/2" x 20-1/2" x 8-3/4", weighs
29 Ibs.
INCLUDES:
No. 35225—Brine Crystallization Kit 10230—Erlenmeyer Flask, 125 ml Glass (4)
30929—Sample Cup (1)
35225—Brine Crystallization Kit in a high-impact, plastic carrying 35684—Generator Tube (5)
case, 18-3/4" x 15" x 7-3/4", weighs 17 Ibs. 35685—Collection Tube (5)
INCLUDES: J3007—5 cc Disposable Syringe (6)
N5282—Cold Plate Magnetic Stirrer J3017—Boiling Stones, 500 G Bottle (1)
N8231—Electronic Printing Thermometer J3019—Hot Plate, 115-volts, AC, 371 °C (1)
N5257—Stirring Bar J3020—#5 Rubber Stopper with 2 Holes (5)
N8203—Thermometer Probe J3021—#5 Rubber Stopper with 1 Hole (5)
33055—High Intensity Flashlight L3979—Tygon Tubing, 1/4" x 1/16" (2 ft)
52600—Nucleating Agent N3000—Graduated Cylinder, 25 ml, Glass (1)
E1053—Instruction N3334—10 cc Plastic Syringe (2)
N5253—Portable Magnetic Stirrer, Battery Operated (1)
64081—IRON CONTENT TEST KIT N5257—Stirring Bar, Magnetic, 3/8" x 1" (2)
N6000—Pipette, Serological, 5 ml (1)
The Iron Content Test Kit has been developed to pro- N6100—Pipette, Serological, 10 ml (1)
vide a quick field test to determine an approximation 11293—Sodium Hydroxide 8N, 4 oz
of the iron (Fet+) content of brines. 51306—Sulfuric Acid N/50, 8 oz
51353—Boric Acid, 2% by Volume, 16 oz
64081—Iron Content Test Kit in a plastic carrying case. 51632—Bromocresol Green - Methyl Red Indicator 1:2, 2 oz
INCLUDES: 52714—Distilled Water, 16 oz
N4545—25 ml Volumetric Flask with glass stopper 50718—SDI Defoamer, 8 oz
N5921—1 ml Volumetric Pipette
52402—1N Nitric Acid, 8 oz
52435—Ascorbic Acid, 10 gm bottle
52912—Deionized water, 8 oz
N3000—25 ml Graduated Cylinder
83111—0.1 gram Scoop
64083—Iron Test Strips

37
50525—FILTRATE ANALYSIS KIT 50025—CHLORIDE CONTENT KIT
The Filtrate Analysis Kit provides the equipment neces- The Chloride Content Kit contains all of the equipment
sary to test drilling mud filtrates for chloride content, alka- and reagents necessary to test fluids for chloride con-
linity, sulfate content, and hardness by the Versenate tent. Results are reported as parts per million (ppm) of
method. In addition to these tests, the lime content of the Chloride (СГ) ion.
mud can be determined.
50025—Chloride Content Kit includes the following equipment in a Steel
Case:
50525—Filtrate Analysis Kit includes the following equipment in a 51000—Potassium Chromate Indicator Solution, 2 oz
Stainless Steel Case: 52200—Silver Nitrate, .001 N, 8 oz, 2 supplied
50703—Versenate Hardness Indicator Solution, 2 02 52300—Silver Nitrate, .01 N, 8 oz, 2 supplied
50707—Versenate Hardness Titration Solution, 2 EPM, 4 oz 52714—Distilled Water, 16 oz, 2 supplied
50711—Versenate Hardness Titration Solution, 20 EPM, 4 oz N3701—Titration Dish
50717—Versenate Hardness Buffer Solution, 4 oz N5900—Pipette, 1 ml, 2 supplied
51000—Potassium Chromate Indicator Solution, 2 oz N6100—Pipette, 10 ml, 2 supplied
51200—Phenolphthalein Indicator Solution, 2 oz N6401—Stirring Rod, 2 supplied
51306—Sulfuric Acid, N/50, 8 oz
51325—Sulfuric Acid, N/10, 4 oz
51600—Methyl Orange Indicator Solution, 2 oz 50426—CHLORIDE, ALKALINITY AND
51800—Calcium Indicator Solution, 1 oz WATER HARDNESS TEST KIT
51900—Sulfate Indicator Solution, 2 oz This kit provides all of the necessary apparatus and
52213—Silver Nitrate, .001N, 4 oz
52306—Silver Nitrate, .01 N, 4 oz
reagents to test for chloride content, alkalinity, hard-
52600—Calcium Carbonate, 2 oz ness by the Versenate Method and calcium content.
52714—Distilled Water, 16 oz
62500—pH Paper, Range 6-9.5 50426—Chloride, Alkalinity, Calcium and Hardness Test Kit includes the
62600—pH Paper, Range 10-14 following equipment in a Stainless Steel Case:
N3100—Graduated Cylinder, 10 ml 50703—Hardness Indicator Solution, 2 oz
N3303—Syringe, 2 cc 50709—Hardness Titration Solution, 2 EPM, 8 oz
N3701—Titration Dish 50711 —Hardness Titration Solution, 20 EPM, 4 oz
N4201—Funnel 50717—Hardness Buffer Solution, 4 oz
N5900—Pipette, 1 ml, 2 supplied 50731—Calcium Buffer Solution, 2 oz
N6000—Pipette, 5 ml 50744—Calcium Indicator Powder, 10gm
N6100—Pipette, 10ml 51000—Potassium Chromate Solution, 2 oz
N6401—Stirring Rod, 2 supplied 51200—Phenolphthalein Solution, 2 oz
N8600—Filter Paper 51306—Sulfuric Acid, N/50,8 oz
51600—Methyl Orange Solution, 2 oz
52200—Silver Nitrate, .001 N, 8 oz
52306—Silver Nitrate, .01 N, 4 oz
52600—Calcium Carbonate Powder, 2 oz
52714—Distilled Water, 16oz
83122—pH Indicator Strips, pkg of 100
N3701—Titration Dish, plastic
N6100—Pipette, 10mix0.1 ml Div
N6401—Stirring Rod, plastic
No. 50525—
Filtrate Analysis Kit

No. 50426—
Chloride Alkalinity and Water Hardness Test Kit

No. 50025—Chloride Content Kit

38
50430—BAROID WATER ANALYSIS KIT 42500—METHYLENE BLUE
The Baroid Water Analysis Kit was developed for pre- ADSORPTION KIT
cise field analysis of water treating problems in oilfield The methylene blue dye test is especially designed to
production installations. This kit contains chemicals, determine the capacity of a clay to adsorb cations from
equipment and glassware for the measurement of solution.
chloride ion, alkalinity, total hardness, calcium ion, Like all cation exchange methods, the methylene
iron, sulfate and pH. blue test measures the total exchange capacity of the
50430—Water Analysis Kit includes the following equipment in a clay system. Results depend on the type and mineral
Stainless Steel Case: content of clay present. The reactive portions of the
50434—Demineralizer Bottle clay are involved. Such materials as finely ground lime-
50438—Alka-Seltzer Tablet, 12 packages supplied stone, sand, and barite do not absorb methylene blue.
50703—Versenate Hardness Indicator Solution, 2 oz
50705—Versenate Hardness Buffer Solution, 2 oz 42500—Methylene Blue Adsorption Kit for Drilling Mud
50713—Titration Solution, 20 EPM, 16 oz INCLUDES:
50731—Calcium Buffer Solution, 2 oz L6150—Electric Hot Plate, thermostatic control, 325-watt, 115-
50744—Calver Indicator Powder, 10 gm volt AC, 60-Hz
50751—Iron Indicator Solution, 2 oz 42513—Methylene Blue Solution, 3.74 gm/liter, 8 oz
50756—Iron Buffer Solution, 2 oz, 2 supplied 50763—Hydrogen Peroxide Solution, 3%, 8 oz
50761—Hydrogen Peroxide, 3%, 2 oz 51833—Sulfuric Acid Solution, 5N, 8 oz
51000—Potassium Chromate Indicator Solution, 2 oz N2900—Graduated Cylinder, 50 ml
51200—Phenolphthalein Indicator Solution, 2 oz N4525—Erlenmeyer Flask, 250 ml
51304—Sulfuric Acid, N/50, 16 oz N5903—Pipette, 3 ml x 1/100 ml
51331—Sulfuric Acid, 5N, 2 oz N6100—Pipette, 10ml
51621—Methyl Purple Indicator Solution, 2 oz N6400—Stirring Rods, glass
52301—Silver Nitrate, .01N, 16 oz 42540—Methylene Blue Adsorption Kit, 230-volt
52451—Hydrochloric Acid, 2 oz
52715—Distilled Water, 32 oz
60300—pH Buffer Solution, pH 7, 16 oz
62400—pH Paper, Range 1-11
63208—Test Tube
63641—Amine Indicator Solution
63643—Amine Buffer Solution, 2 oz
64011—Sulfide Ion Indicator Solution, 2 oz
64023—Sulfide Ion Titration Solution, 8 oz
64031—Lead Acetate Disc
64032—H2S Bottle
64033—Color Chart for H2S
No. 42500—
J4032—Stopper
Methylene Blue
N1901—Automatic Burette, 10 ml, 3 supplied
Adsorption Kit
N2800—Graduated Cylinder, 100 ml
N3701—Titration Dish
N4613—Pouring Spout
N5900—Pipette, 1 ml
N6100—Pipette, 10ml
N6401—Stirring Rod, 2 supplied

35308—ALTERNATE FILTRATE
ALKALINITY TEST KIT
The alternate filtrate alkalinity test is prescribed in API
Procedure RP 13B and is frequently required for com-
pletion of the drilling mud report form. This kit is fully
equipped with all the necessary labware, reagents,
and other supplies for the analysis of filtrate alkalinities
Pf, M,, P1 and P2. 50725—HARDNESS TITRATION KIT
35308—Alternate Filtrate Alkalinity Test Kit, complete (VERSENATE METHOD)
INCLUDES: The Hardness Titration Kit provides a quick, accurate
10305—Pipette 2 ml serological TD CC-GRN field method for determining calcium and magnesium
10339—Rod Stirring 6" Glass ion concentrations in water of mud filtrates.
11343—Clamp Fiberglass Utility
11371—Methyl Orange Bromocresol Green, 2 oz
50725—Versenate Hardness Titration Kit in stainless steel case,
11376—Barium Chloride 10%, 16 oz 6-1/2" x 10-3/4" x 10-3/4" with:
35309—Burette 25 ml Acrylic w/tfl stpck td 50703—Hardness Indicating Solution, 2 oz
51200—Phenolphthalein Indicator Solution, 2 oz 50708—Buffer Solution, 8 oz
51600—Methyl Orange Indicator Solution, 2 oz
50709—Hardness Titrating Solution, 1 ml equiv to 2 epm, Ca
52101—Sodium Hydroxide N/10, 16 oz
plus Mg using 1 ml sample, in polyethylene bottle, 8 oz
52483—Acid Hydrochloric N/50, 8 oz 50712—Hardness Titrating Solution, 1 ml equiv to 20 epm, Ca
52713—Distilled Water, 8 oz plus Mg using 1 ml sample, in polyethylene bottle, 8 oz
62500—Hydrion Disp Sr w/pH 6-8 & pH 8-9.5
52714—Distilled Water, 16 oz, in polyethylene bottle, 2 supplied
62603—Hydrion Refill pH 9-12 N3701—Titration Dish, 140 ml
83121—pH Indicator Strips 100 pkg, 7.5-14
N6100—Pipette, Serological, 10 ml, 2 supplied
N3000—Cylinder Graduated, 25 ml, Glass "TC"
N6401—Stirring Rod, polyethylene, 2 supplied
N3100—Cylinder Graduated, 10 ml, Glass "TD"
N3701—Titration Dish, Plastic, 140 ml
N5900—Pipette, 1 ml, Serological
39
83057—PILOT TESTING KIT 83066—OIL MUD TEST KIT
The Pilot Testing Kit has been developed as a companion The Oil Mud Test Kit contains a rheometer with cup
kit to the Offshore Kits. It is contained in a stainless steel and heater, retort kit, mixer, emulsion tester, aniline
case that is 15-in. long, 12-in. high and 7-in. wide and test kit, chemicals, glassware and all equipment nec-
weighs approximately 30 Ib. This includes the Pocket Mud essary for the field testing of oil muds. The stainless
Balance, the Half Area Filter Press, a Portable Mixer, and steel case containing the kit is 9" x 12" x 26". The
Baroid mud product samples. complete kit weighs 55 Ibs.
83057—Pilot Testing Kit includes the following equipment in a Stainless
Steel Case: 83066—Oil Mud Test Kit, includes the following equipment in a
14200—Pocket Mud Balance Stainless Steel Case:
20200—Measuring Cup, 1000 ml 10362—Thermometer, 0-220°F
30205—1/2 Area Filter Press 20200—Measuring Cup, 1000ml
52712—Distilled Water, 4 oz, 3 supplied 25120—Cup Heater, 115-volt
N0000—Portable Balance 28000—Rheometer, Hand Crank
N3100—Graduated Cylinder, 10ml 35712—Emulsion Stability Tester, Model 23D
N3101—Graduated Cylinder, 5 ml, 2 supplied 50703—Versenate Hardness Indicator Solution, 2 oz
N3701—Titration Dish 50705—Versenate Hardness Buffer Solution, 2 oz
N5201—Mixer 50711—Titration Solution, 20 EPM, 4 oz
N5900—Pipette, 1 ml 51000—Potassium Chromate Indicator Solution, 2 oz
N6000—Pipette, 5 ml 51200—Phenolphthalein Indicator Solution, 2 oz
N6100—Pipette, 10 ml 51325—Sulfuric Acid, N/10,4 oz
N6401—Stirring Rod, 2 supplied 52103—Sodium Hydroxide, N/10,4 oz
N7300—Spatula, 4" 52306—Silver Nitrate, .01N, 4 oz, 4 supplied
N7700—Timer, 30 minute 52501—Wetting Agent, 1 oz
Plus Chemical Samples in 2 oz Bottles, 1 set 52712—Distilled Water, 4 oz, 4 supplied
52900—Slik 5 (Concentrate), 8 oz
30504—Basic Mud Testing Kit includes the following equipment in a 53675—Exosol-lsopropyl, 8 oz, 3 supplied
Stainless Steel Case: 55115—AKTAFLO®-E Solution, 8 oz
14001—Mud Balance 63206—Pipette Dropper, 1 ml
20100—Marsh Funnel Viscometer 63207—Rubber Bulb
20200—Measuring Cup, 1000 ml 64102—Aniline Solution, 2 oz
20700—Stopwatch 83051—Retort, Removable
20801 —Rubber cover for Stopwatch 87004—Spatula, for Retort
30800—Filter Press, wall mount with CO2 assembly 87009—Lubricant, High Temperature
40101 —Sand Content Screen 87015—Corkscrew
40201 —Sand Content Funnel 87016—Steel Wool
40300—Sand Content Tube 87017—Pipe Cleaner
50703—Hardness Indicator Solution, 2 oz J3006—Test Tube
50705—Hardness Buffer Solution, 2 oz N1300—Brush, large
50707—Hardness Titration Solution, 2 EPM, 4 oz N1400—Brush, medium
50711 —Hardness Titration Solution, 20 EPM, 4 oz N2701 —Clamp for Test Tube
50731 —Calcium Buffer Solution, 2 oz N2900—Graduated Cylinder, 50 ml
50744—Calver Indicator Powder, 10 gm N3100—Graduated Cylinder, 10 ml, 2 supplied
51000—Potassium Chromate Indicator, 2 oz N3303—Syringe, 2 cc
51200—Phenolphthalein Indicator Solution, 2 oz N3325—Syringe, 10cc
51306—Sulfuric Acid, .02N, 8 oz N3701—Titration Dish
51600—Methyl Orange Indicator Solution, 2 oz N4525—Erlenmeyer Flask, 250 ml
52200—Siiver Nitrate, .0282N, 8 oz N5201—Mixer
52306—Silver Nitrate, .282N, 4 oz N5900—Pipette, 1 ml, 2 supplied
52600—Calcium Carbonate Powder, 2 oz N6000—Pipette, 5 ml, 4 supplied
52714—Distilled Water, 16 oz N6100—Pipette, 10ml
83122—pH Indicator Strips, Range 1-14 N6401—Stirring Rod
N3701—Titration Dish, Poly N7200—Spatula, 6-in.
N5900—Pipette, Serological, 1 ml N7901 —Thermometer
N6000—Pipette, Serological, 5 ml N8202—Thermometer, Digital
N6100—Pipette, Serological, 10 ml N9200—Particle Size Plate
N6401—Stirring Rod, plastic
N7901—Thermometer, 50-350°F

No. 83066-
No. 30504—Basic Mud Testing Kit ОМ Mud Test Kit
40
83053—AIRPLANE KST OFFSHORE KITS
The Airplane Kit contains a rheometer, retort kit, mixer for The Offshore Kits are smaller and lighter weight. The kit
pilot testing, half area filter press complete, sand content case forms a work table surface when opened. Space is
set, pH papers, chemicals and glassware for chloride, available for the pocket mud balance and one of the min-
alkalinity and water hardness tests. iature filter presses when required. The kits are 201/2-in. x
12-in. x 7-in. and weigh 34 Ib with the rheometer in place.
83053—Airplane Kit includes the following equipment in a Stainless
Steel Case: 83054—Offshore Kit, less Rheometer
20700—Stopwatch 83055—Offshore Kit, with Rheometer
20801 —Rubber Cover for Stopwatch
28000—Rheometer, Hand Crank Baroid Offshore Kits include the following equipment in a Stainless Steel
28055—Sample Cup, Stainless Steel, for Rheometer Case:
30205—Filter Press, 1/2 area 40101—Screen, for Sand Content
40101—Sand Content Sieve 40201 —Funnel, for Sand Content
40201—Sand Content Funnel 40300—Tube, 0-20%, for Sand Content
40300—Sand Content Tube 50703—Versenate Hardness Indicator Solution, 2 oz
50703—Hardness Indicator Solution, 2 oz 50705—Versenate Hardness Buffer Solution, 2 oz
50705—Hardness Buffer Solution, 2 oz 50707—Titration Solution, 2 EPM, 4 oz
50707—Hardness Titration Solution, 2 EPM, 4 oz 50711—Titration Solution, 20 EPM, 4 oz
50711—Hardness Titration Solution, 20 EPM, 4 oz 51000—Potassium Chromate Indicator Solution, 2 oz
51000—Potassium Chromate Solution, 2 oz 51200—Phenolphthalein Indicator Solution, 2 oz
51200—Phenolphthalein Solution, 2 oz 51323—Sulfuric Acid, N/50,4 oz
51323—Sulfuric Acid, N/50,4 oz 51325—Sulfuric Acid, N/10,4 oz
51325—Sulfuric Acid, N/10,4 oz 51600—Methyl Orange Indicator Solution, 2 oz
51600—Methyl Orange Solution, 2 oz 52213—Silver Nitrate, .001N,4oz
51800—Calcium Indicator Solution, 2 oz 52306—Silver Nitrate, .01 N, 4 oz
51900—Sulfate Indicator Solution, 2 oz 52501—Wetting Agent, 1 oz
52213—Silver Nitrate, .001N,4oz 52712—Distilled Water, 4 oz, 2 supplied
52306—Silver Nitrate, .01N, 4 oz 62600—pH Paper, Range 10-14
52501—Wetting Agent, 1 oz 83051—Retort, Removable
52712—Distilled Water, 4 oz, 2 supplied 87004—Spatula, for Retort
62400—pH Paper with Dispenser, Range 1 -11 87009—Lubricant, High Temperature
62500—pH Paper with Dispenser, Range 6-9.5 87015—Corkscrew
62600—pH Paper with Dispenser, Range 10-14 87016—Steel Wool
63201—ALDACIDE® Test Solution A, 2 oz 87017—Pipe Cleaner
63202—ALDACIDE Test Solution B, 2 oz N1401—Brush, small
63203—ALDACIDE Test Solution C, 2 oz N3100—Graduated Cylinder, 10 ml, 2 supplied
63204—ALDACIDE Test Solution D, 2 oz N3303—Syringe
83051—Removable Retort, comb 115-volt and 12-volt N3701—Titration Dish
87004—Retort Spatula N5900—Pipette, 1 ml, 2 supplied
87009—Lubricant, High Temperature N6000—Pipette, 5 ml
87015—Corkscrew N6100—Pipette, 10ml
87016—Steel Wool, V* Ib N6401—Stirring Rod, 2 supplied
87017—Pipe Cleaner
N1401—Brush, small
N1500—Brush, Pipette
N3100—Graduated Cylinder, 10ml
N3303—Syringe, 2 cc
N3701—Titration Dish, 140 ml, plastic
N5201—Mixer, for Measuring Cup
N5900—Pipette, 1 ml x .01 ml Div
N6000—Pipette, 5 ml x 0.1 ml Div
N6100—Pipette, 10mix0.1 ml Div
N6401—Stirring Rod, plastic, 2 supplied
N7300—Spatula, Stainless Steel Blade, 4 supplied
N7901—Thermometer, 50-350° F
N9200—Particle Size Plate w/Scraper

No. 83055—Offshore Kit with Rheometer

No. 83053—Airplane Kit

41
83014—BAROID PORTABLE MUD 82100—BAROID RIG LABORATORY
LABORATORY The Baroid Rig Laboratory contains the basic mud testing
The Baroid Portable Mud Laboratory is a complete mud equipment required for routine mud checks by rig per-
testing unit designed particularly for Drilling Mud Engi- sonnel. It is designed for long life and easy maintenance
neers. It is ideally suited for automotive laboratory use. under field conditions. The kit is contained in a stainless
The two main units weigh 40 Ib and 35 Ib, respectively. The steel cabinet 261/2-in. x 25-in. x 11-in. and weighs only 75
case fronts fold down to provide work tables. pounds.

Complete Unit 82100—Baroid Lab consists of the following equipment in a Stainless


83014—Baroid Portable Mud Laboratory, complete with No. 28000 Steel Cabinet:
Baroid Rheometer, ready for mounting in trunk of automobile. 14001—Baroid 4-scale Mud Balance
Uses No. 83055 and No. 83057 Kits plus additional supplies. 20100—Marsh Funnel Viscometer
20200—Measuring Cup, 1,000 ml
20700—Stop Watch, 7-jewel
20800—Stop-Watch Cover
30600—Filter Press, Wall Mount
32800—Screen, 60-mesh (spare)
33514—Air Hose, 12-in.
33610—Air Hose Adapter
33800—CO2 Pressuring Assembly
40001 —Baroid Sand Content Set
51000—Potassium Chromate Indicator Solution, 2 oz
52200—Silver Nitrate .001 in polyethylene bottle, 8 oz
52300—Silver Nitrate .01 in polyethylene bottle, 8 oz
52713—Distilled Water in polyethylene bottle, 8 oz
62400—Wide Range Hydrion pH Dispenser, pH 1-11
62600—Short Range, Hydrion pH Dispenser, pH 10-14
N1300—Brush, Large, with wooden handle
N1401—Brush, test tube, small
N3000—Graduated Cylinder, 25 ml
N3100—Graduated Cylinder, 10ml
N3701 —Titration Dish, Polyethylene, 140 ml
N5900—Pipette, Serological, 1 ml
N6100—Pipette, Serological, 10ml
N6401—Stirring Rod, Polyethylene
No. 83014—Portable Mud Laboratory N7800—Interval Timer
N7901—All-Metal Thermometer 50-350° F
N8700—Filter Paper, pkg of 100,2 supplied

82101—Baroid Rig Lab contains same equipment as No. 82100 except


the No. 33500 Dead-Weight Hydraulic Unit replaces the No
33800 C02 Pressuring Assembly
82140—Baroid Rig Lab, with sink, contains same equipment as No.
82100 except that it is larger, has sink and water connections

No. 82100—Rig Laboratory No. 82140—Rig Laboratory with Sink

42
41000—MEMBRANE FILTER TESTER 41200—RESIDUAL OIL FILTRATION KIT
The Membrane Filter Tester has been developed to pro- The Residual Oil Filtration Kit provides a rapid and accu-
vide a qualitative and quantitative test for determining rate field test for determination of small amounts of oil in
various aspects of water quality. Relative filtration rates, water. The kit can be used to provide data for the following
quantity and composition of suspended solids can be field problems: (1) efficiency of precipitators or skimming
established. The Tester can be used effectively to provide tanks with or without chemical treatment, (2) efficiency of
data for the following water problems: (1) relative plugging an emulsion breaker in a treating system, (3) amount of
tendencies, (2) chemical compatibility, (3) suspended residual oil in produced water relevant to plugging of
native solids such as sand, clay, etc., (4) suspended corro- filters and the formation face, (4) amount of residual oil in
sion by-products such as iron sulfide, (5) suspended alka- produced water relevant to contamination of public
line earth metal precipitates such as calcium carbonate, waters (streams, lakes, bays, etc.) as observed by state
calcium sulfate, etc., (6) biological by-product contamina- regulatory agencies.
tion, (7) effect of entrained hydrocarbons on filtration.
41200—Residual Oil Filtration Kit, complete, in carrying case
41000—Membrane Filter Tester, Less Pressuring Device INCLUDES:
41001—Case for No. 41000 41202—Filter Press w/C02 Pressuring Assembly
41002—C02 Pressuring Device N8747—Millipore Filter, ЗУг-in., 0.45 micron, 10 per box
41003—Nitrogen Pressuring Device N3220—Centrifuge Tube, 100 ml, stoppered, stem graduated 0.2 ml x
0.1 ml
N4201—Separatory Funnel, 125 ml
52797—Pentane, technical grade, 1 gal can
L6150—Hot plate, 115-voll, 300-watt
60260—Beaker, stainless steel, 600 ml

No. 41000—
Membrane Filter Tester

No. 41200—Residual Oil Filtration Kit


MODEL 440, FANN CAPILLARY SUCTION
TIMER
The FANN Capillary Suction Timer (CST) is an instrument
that measures the filtration rate of free water in aqueous
systems between two electrodes using filter paper as the
medium. The CST value is primarily an indication of cake
permeability, and has many industry applications in deter-
mining how fluids of different ionic composition and
product mix will disperse solids.
The instrument is ideal for use in the field as it oper-
ates on one 9-volt battery. The complete unit consists of
a timer unit, test head assembly with funnel, 9-volt bat-
tery and battery eliminator (115-volt), one box of filter
paper and instructions.
44000—Capillary Suction Timer Instrument

Replacement Parts:
N8806—Filter Paper, box of 170
L4409—Battery, 9-volt
44007—Funnel, Stainless Steel
60012—Battery Eliminator, 115-volt
60013—Battery Eliminator, 230-volt
No. 44000—Capillary Suction Timer
Optional Equipment:
44050—Swell Meter
N5515—Blender, Seven Speed
N5501—Mini-cup, 12-37CC

43
No. 63642—Galvanic Corrosion Monitor
Rod Flat Coupons Drill Pipe
Coupon Corrosion
Coupon

DRILL PIPE CORROSION COUPONS


Drill Pipe Corrosion Coupons are used to study the
corrosive effects of a drilling fluid on drill pipe and to
evaluate the effectiveness of corrosion inhibitor treat-
ing programs.
All Drill Pipe Corrosion Coupons are made of CD
seamless mechanical tubing, type 4130, machine-fin-
ish steel. Each coupon has a serial number stamped
63642—GALVANIC CORROSION MONITOR into it. Each coupon is packaged in a coupon enve-
The Galvanic Corrosion Monitor is an instrument lope with a vapor-type inhibitor material to prevent
which continuously monitors the corrosion characteris- atmospheric corrosion.
tics of a fluid. The instrument consists of two elec- Recorded on the coupon envelope are the coupon
trodes mounted in a high pressure pipe plug,.which serial number, the initial weight, the size and the К
are connected to a microammeter mounted in a factor for calculating corrosion rate. Due to the varia-
weather resistant housing. The microammeter regis- tion in size of the drill pipe box where the coupon is
ters current generated by the corrosion occurring on placed, there may be a slight problem in obtaining a
the electrodes while they are suspended in the fluid. good fit; i.e., not too loose and not too tight. The over-
Observation of the galvanic current produced provides lap in coupon sizes listed below should remedy this
a qualitative estimate of the corrosion rate. problem.
Drill pipe size and type are listed in order of best fit.
63642—Galvanic Corrosion Monitor The reweighing of Drill Pipe Corrosion Coupons shall
INCLUDES: be the customer's responsibility. This is usually done
63645—Steel Electrode with insulator and connectors locally to obtain the weight loss information quickly.
63646—Brass Electrode with insulator and connectors
63647—2-in. NPT High Pressure Pipe Plug Instructions for cleaning, weighing and calculating the
E2002—Microammeter corrosion rate are included with each envelope.
B1007—Weather Resistant Housing
B1006—Housing Cover
Coupon Size Drill Pipe Size & Type
No. 63618— 2%-in. internal flush
2'/2-in.ODx0.250-in. wall and 3!/2-in. slim hole
Coupon Holders
No. 63619— 31/2-in. x-tra hole
Ш» j 23/4-in.ODx0.188-in.wall and 31/2-in. full hole
No. 63620— 3'/2-in. internal flush
3-in. ODx 0.313-in. wall and 31/2-in. x-tra hole
No. 63621 — 4-in. full hole
3'/4-in.ODx0.250-in. wall
No. 63623— 4-in. internal flush
33/4-in. OD x 0.3125-in. wall and 4'/2-in. x-tra hole
No. 63612 No. 63610 No. 63609
No. 63624— 41/2-in. full hole and 41/2-in. x-tra hole
35/e-in. OD x 0.375-in. wall and 4-in. internal flush
CORROSION COUPONS AND HOLDERS No. 63625— 41/2-in. internal flush
Baroid Corrosion Coupons and Holders are used to 41/2-in.ODx0.3125-in.wall and 5-in. x-tra hole
study the corrosion effects of fluids and to evaluate No. 63626— 59/ie-in. or 51/2-in. API regular
the effectiveness of corrosion inhibitor treatment pro- 45/a-in. OD x 0.500-in. wall orfullholeand6 5 /e-in. API regular
grams. Other sizes (not listed) are available by special No. 63629— 4!/2-in. x-tra hole
order. 3"/ie-in. OD x 0.200-in. wall
No. 63631— 5-in. x H Tool Joint
63600—Nylon Post, f/63609 and 63610 43/«-in. OD x 0.2185-in. wall
63601—Rod Coupon '/4 in. dia. x3 1 /2 in.
63605—Rod Coupon Vi in. dia. x 3 in.
63606—Rod Coupon 1/4 in.dia. x2 1 /2 in. 63675—RETRACTABLE COUPON HOLDER
63607—Rod Coupon % in. dia. x 13/i in. To insert corrosion coupons into a pressurized line
63608—Rod Coupon V4 in. dia. x 2 in. through a valve without shutting down the line, use a
63609—Flat Coupon Holder, 1 in. NPT
63610—Flat Coupon Holder, 2 in. NPT Baroid Retractable Coupon Holder. The stroke of this
63611—Grommets for No. 63610, package of 10 holder is 15 in., but allowances must be made for valve
63612—Rod Coupon Holder, Mulfrchuck, 2 in. NPT and fittings.
63614—Rod Coupon 1/4 in. dia. x 4-1/2 in.
63615—Scale Coupon, 1/16 in. x 1 in. x 3 in. with holes
63616—Flat Coupon, 1/16 in. x 1 in. x 3 in.
63634—Prestressed Roller Bearing, package of 10
63638—Flat Coupon 3/4 in. x 3 in. No. 63675—Retractable Coupon Holder
44
ANILINE NUMBER, FLASH POINT AND 64100—ANILINE POINT
FIRE POINT TEST KIT DETERMINATION KIT
This test is used for analysis of oil muds. The aniline The aniline point of oil indicates the oil's aromatic content.
number of a hydrocarbon solvent, such as diesel oil, is Oils with high aromatic content are detrimental to rubber
determined in accordance with ASTM Test Procedure D products such as those commonly found on drilling rigs.
611. The aniline point is defined as the minimum equal The Aniline Point Determination Kit is designed specifi-
solution temperature for equal volumes of aniline and cally for use in finding the aniline point of oils used in
solvent. At this temperature, the two liquids will be com- drilling muds so that damage to rubber parts from the oil
pletely miscible, changing from a cloudy to a clear solu- can be minimized.
tion. The aniline point is a measure of the percentage of
aromatic constituents in the diesel or fuel oil, which cause 64100—Aniline Point Determination Kit, complete
damage to rubber parts and/or a change in the solubility
of the emulsifiers used in the drilling fluid.
The test for flash point and fire point by the Cleveland
Open Cup is in accordance with ASTM Test Procedure D
92 for petroleum products. The flash point is defined as
the temperature at which a flash appears at any point on
the surface of the oil when a flame is passed over the
center of the cup 1/e-inch above the top of the cup. The
fire point is defined as the temperature at which the oil
No. 64100—Aniline Point
ignites and continues to burn for at least five seconds Determination Kit
when the flame is passed over the cup. This apparatus is
intended for field use and the temperature of the flash
point and the fire point measured in the open cup are
normally 15 to 20 percent higher than the values obtained
by laboratory apparatus such as the Pensky-Martens NITRATE ION CONCENTRATION KIT
Closed Cup Tester. Fluids recovered from formation tests often are difficult to
identify as being either filtrate or connate water. The
11369—FANN Aniline Number, Flash Point, and Fire Point Test Kit
INCLUDES:
nitrate ion can be used as a tracer in the mud filtrate to
10120—Beaker, 250 ml permit a better evaluation to be made. Samples are mea-
11347—Cup, Flash Point, Cleveland Open-Cup type sured on a color wheel and compared to a blank.
11343—Clamp, Utility, with fiberglass jaw covering
10307—Pipette, Graduated/Measuring, 10 ml, glass, 2 supplied
11641—Pipette, Pi-Pump® Filler/Dispenser, capacity 10ml
11338—Test Tube, 25 x 150 mm
11339—Test Tube, 38 x 200 mm
11342—Thermometer, glass, 77° to 221 °F for ASTM Aniline Point
11340—Stopper, Cork, No. 10
11341—Stopper, Cork, No. 20
11095—Hot Plate, 325-watts, 115-volts, 50/60-Hz
35328—Stirrer, Manually Operated, Metal, for Aniline Test
Reagents:
11344—Aniline, Reagent Grade, 16 oz.
35323—Calcium Sulfate, Anhydrous, 2 oz.
References:
1. ASTM D 611. Test for Aniline Point and Mixed Aniline Point of Petro-
leum Products and Hydrocarbon Solvents.
2. ASTM D 92. Test for Flash Point and Fire Point by Cleveland Open No. 11453—Nitrate Ion
Cup. Concentration Kit

LOW RANGE NITRATE TEST KIT 11453—Nitrate Ion Concentration Kit


INCLUDES:
MODEL N1-14 (HACH METHOD) Beaker, plastic, 150ml
For more sensitive nitrate testing, down to 0.02 mg/L, use Bottles and Caps for Standard Solutions, 4 oz., 2 supplied
Model N1-14 Low Range Nitrate Test Kit. The kit uses a Color Disk for Nitrate Test
Comparitor Box, plastic
stable powder reagent, NitraVer® 6 Nitrate Reagent, Dropper, 2 ml, plastic
which produces a brilliant coral pink color in proportion to Filter Paper, Whatman No. 2,11.0 cm, box of 100 circles
the amount of nitrate in the water sample. An analysis can Funnel, plastic, analytical
be performed in minutes. Graduated Cylinder, 10 ml, glass, calibrated "TD" at 20°C
Graduated Cylinder, 100 ml, plastic, calibrated TC/TD at 20°C
Pipette, Graduated/Measuring, glass, 1 ml (Kimax 37079)
Ranges: 0-1 ml/L and 0-10 mg/L as nitrate nitrogen Test Tube and Stopper, pack of 4,2 supplied
Smallest Increment: 0.02 and 0.2 ml/L Case, for Nitrate Ion Kit
Sample: 5 mL and 0.5 mL Instruction, Test Guide Chart and Parts List
Analysis Method: Colorimetric (color disc)
Reagents:
Number of Tests: 50 11538—Nitrate Test Reagent, powder pillow, NO311, pack of 100
Case: 15.9 x 12.7 x 3.8 cm (6.25 x 5 x 1.5") 11539—Nitrate Test Reagent, powder pillow, NO 12, pack of 100
Shipping Weight: 0.45 kg (1 Ib)

45
64030—HYDROGEN SULFIDE 55200—GARRETT GAS Т
DETECTION KIT The Garrett Gas Train measures the concentration of
The Baroid Hydrogen Sulfide Detection Kit provides a sulfides or carbonates in water-based drilling fluids. This
rapid and inexpensive procedure for detection of H2S. This measurement gives an indication of the rate and amount
Colormetric method can be used to detect as little as 0.3 of intrusion of hydrogen sulfide or carbon dioxide from
ppm H2S. The kit contains all the hardware and reagents, formations to drilling fluids. Also, the Garrett Gas Train
including the color comparison chart, needed for H2S separates the hydrogen sulfide or carbon dioxide from the
detection. liquid phase of the mud sample for quantitative analyses.
Lead acetate paper discs can be used for determining
64030—Hydrogen Sulfide Detection Kit, consisting of: the presence of sulfides. For quantitative sulfide measure-
64031—Lead Acetate Paper Discs, pkg of 100 ments, the H2S low-range (0 to 120 ppM) or H2S high-range
64032—Hydrogen Sulfide Test Bottle (60 to 4080 ppM), Draeger tubes may be used.
64033—Hydrogen Sulfide Color Chart with instructions
For quantitative carbonate measurements, the C02
Draeger tubes may be used. CO2 or N2 should be used as
the inert gas supply for sulfide tests. N20 or N2 should be
used for carbonate tests.

Complete Kit
55200—Garrett Gas Train complete in plastic case

No. 64030— Supplies and Replacement Parts


Hydrogen Sulfide L3979— '/4-in. Tygon Tubing
Detection Kit L4674—О Ring
L4675—О Ring (2 spares recommended)
33601—CO2 Cartridges, box of 10
33602—N2O Cartridges, box of 10
33606—Cartridge Adapter Barrel
33620—Cartridge Adapter Head
33700—Regulator
51334—Sulfuric Acid 5N, 16 oz bottle
55202—Thumb Screw
55203—C02 Draeger Tubes, box of 10
63691—BAROID SCALE 55204—Fritted Disc, (Dispersion Tube)
DEPOSITION TEST CELL 55206—H2S Draeger Tubes, box of 10 (0 to 120 ppM)
The Baroid Scale Deposition Test Cell has been developed 55208—H2S Draeger Tubes, box of 10 (60 to 4080 ppM)
for the purpose of studying the mechanics of scale depo- 55211 —One Liter Gas Bag
55212—Draeger Hand Pump
sition and the efficiency of scale inhibitor chemicals in the 55213—Stopcock
laboratory. This instrument is designed to simulate min- 55215—Injection Gasket
eral scale deposition. By comingling two incompatible 64031 —Lead Acetate Paper Discs, pkg of 100
laboratory-prepared waters under controlled temperature N3000—Graduated Cylinder, 25 ml
N3332—Plastic Syringe, 3 cc, 22 ga 11/2-in. needle
and pressure conditions, a mineral scale can be depos- N3334—Plastic Syringe, 10 cc, 22 ga 1 '/2-in. needle
ited in several minutes inside a tubular test coupon 50700—Surflo Defoaming Agent
through which the fluid is passed. Scale inhibitors can
then be screened according to their ability to inhibit depo- Optional Nitrogen Supply
sition. 31700—Hose, 3-ft
33513—Adapter, Ye-in. NPTx Eastman
63691—Baroid Scale Deposition Test Cell, Portable Laboratory Model, 34005—N2 Cylinder
two aluminum 4,000 ml chambers, 5 psi maximum working 34265—Regulator Assembly, N
pressure, 200°F maximum temperature, 1000-watts, 115-volts
AC thermostatically controlled, complete with pressure control

No. 63691 —
Scale Deposition
Test Cell

No. 55200—Garrett Gas Train

46
50750—IRON (TOTAL) TITRATION KIT 63640—AMINE DETECTION TEST KIT
The Iron (Total) Titration Kit has been developed to The Amine Detection Test Kit has been developed to
provide a quick and accurate field test for determining provide a rapid qualitative test for use in the field to
the total iron content in water. This test is helpful in determine when fatty amine-type inhibitors are pre-
establishing the presence and/or severity of corrosion. sent in produced water and other water systems.
50750—Iron (Total) Titration Kit (apparatus only, no case) 63640—Amine Detector Test Kit (apparatus only, no case),
INCLUDES: INCLUDES:
50702—Hardness Titrating Solution, 1 ml equiv to 2 epm Ca plus Mg 63641 —Amine Indicator Solution, 2 oz, in dropper bottle
using 1 ml sample, I6oz 63646—Amine Buffer Solution, 2 oz, in dropper bottle
50713—Hardness Titrating Solution, 1 ml equiv to 20 epm Ca plus Mg N6100—Pipette, Serological, 10 ml x 1/10 ml
using 1 ml sample, 16oz 63208—Test Tube
50751—Iron Indicator Solution, 2 oz, in dropper bottle
50756—Iron Buffer Solution, 2 oz, in dropper bottle
50761 —Hydrogen Peroxide, 3 % Solution, 2 oz, in dropper bottle
64010—SULFIDE ION TEST KIT
52400—Nitric Acid, 3N, 3 oz The Sulfide Ion Test Kit has been developed to provide an
52451—Hydrochloric Acid, Concentrated, 37%, 2 oz, with dropper accurate field test for determining sulfide ion concentra-
62400—Wide Range Hydrion pH Dispenser w/one roll Hydrion Paper tions in oil field brines. Sulfide ion determinations are
A, pH 2-10 and one roll Hydrion Paper B, pH 1 -11 helpful in establishing whether a system is experiencing
N1901—Burette, Automatic, 10 mix 0.1 ml
N2800—Cylinder, Graduated, 100 ml sour or sweet corrosion. Sulfide ion tests are also useful
N3701—Titration Dish, Polyethylene, 140ml as supplementary tests in determining the presence of
N5900—Pipette, Serological, 1.0 ml x 1/100 ml sulfate, reducing bacteria and sulfide-producing bacterial
N6401—Stirring Rod, Polyethylene, 4 in. activity in a given system. The test is accurate over a
range of 0.1 ppm to 1,000 ppm.
50432—SCALE SOLUBILITY TEST KIT
The Scale Solubility Test Kit provides a rapid qualitative 64010—Sulfide Ion Test Kit (apparatus only, no case),
and quantitative field laboratory test for determining INCLUDES:
whether a scale sample of unknown composition is acid 64011 —Starch Indicator Solution, 2 oz, in dropper bottle
64016—Buffer Solution, 2 oz, in dropper bottle
soluble (calcium carbonate) and its percent solubility. The 64023—Iodine Titrating solution, 8 oz
test is helpful in determining whether an acidizing treat- N5900—Pipette, Serological, 1 ml x 1/100 ml
ment will effectively clean a system. The test is applicable N6100—Pipette, Serological, 10 ml x 1 /10 ml
to calcium carbonate scale only. N2800—Cylinder, Graduated, 100 ml
N0810—Bottle, Paragon, glass with black plastic lid, 8 oz
50432—Scale Solubility Test Kit (apparatus only, no case)
FANN ZINC CARBONATE TEST KIT, ZnC03
SPECIAL PURPOSE TEST KITS Zinc Carbonate may be used to scavenge hydrogen sul-
63200—ALDACIDE Test Kit, consisting of: fide from water base drilling fluids. Hence, it may be nec-
63201 —ALDACIDE Test Solution A, 2 oz dropper bottle
63202—ALDACIDE Test Solution B, 2 oz essary to monitor the available ZnC03 in the mud.
63203—ALDACIDE Test Solution C, 2 oz (should be used within 60
days after opening) 11594—Zinc Carbonate Test Kit, complete
63204—ALDACIDE Test Solution D, 2 oz INCLUDES:
63205—Dropper Pipette, 1 ml in test tube 10119—Beaker, 150 ml, Griffen
51920—Sulfate Ion Test Kit 10157—Graduated Cylinder, glass, 10 ml
55043—Surfactant Reagent No. 1 10158—Graduated Cylinder, glass, 25 ml
63500—Sodium Chromate Test Kit 10160—Graduated Cylinder, glass, 100 ml
64000—Sulfide Ion Test Kit 10307—Pipette, Graduated/Measuring, 10 ml, 2 supplied
64010—Sulfide Ion Test Kit No. 2 for greater accuracy 11507—Funnel, Analytical, 100 mm, plastic
64043—Sulfide Stabilizing Solution 11502—Filter Paper, 18.5 cm. fluted, box of 100
This solution is for the treatment of drilling mud samples in the field 11593—Syringe, glass, 10 cm3
before sending them in for laboratory analysis. Prevents loss of sul- 11483—Syringe, glass, 30 cm3
fides in transit. 11596—pH Strips, pH range 7.5 to 14
10339—Stirring Rod, 6-inch, glass
Instructions for Zinc Carbonate Test Kit

Reagents:
11560—Acetic Acid, Glacial, 16 oz, 2 supplied
No. 63200— 11610—Ammonium Fluoride, 10%,32oz
ALDACIDE Test Kit 11612—Ammonium Hydroxide, Concentrated, 16 oz, 2 supplied
11607—Calcium Titration Solution 1,10% Hydroxylamine Hydrochlo-
ride, 16oz
11608—Calcium Titration Solution II, 30% Sodium Cyanide, NaCN,
16 oz
10470—Deionized Water, 6 oz
11611 —Formaldehyde Solution, 4 %, 32 oz
11424—Hardness Indicator Solution, Manver, 2 oz
10445—Versenate Standard Solution, 0.01 Molar EDTA, 32 oz

47
HIGH SPEED MIXERS AND BLENDERS
Baroid supplies a variety of high speed mixers and
blenders which are used for the preparation of drilling
fluids and for pilot testing, and for use with the various test
kits related to fluids analysis.

FANN MIXERS
No. N5000—
FOR DRILLING Hamilton-Beach No. N5020—
FLUIDS Mixer Multi-Mixer

HAMILTON BEACH MIXERS AND


The FANN Laboratory MULTIMIXERS
Three-speed Hamilton Beach Mixers and five-spindle
Mixer has been
Multimixers are supplied for general purpose mixing use
developed as the in drilling fluids test laboratories. Both mixers are avail-
successor to the able for 115 or 230-volts, 60-Hz power with the standard
two-speed Hamilton impeller blades provided by each manufacturer. A sound
Beach mixer resistant-chamber is available for the Multimixer.
which is no longer
manufactured. These N5000—Hamilton Beach Mixer, 3 test speeds, 115-volt, 60-Hz. No-load
are supplied with the test speeds are 18,000,16,000 and 13,000 rpm. Complete with
standard mud impeller blade for mixing either water base stainless steel mixing cup and automatic starting switch.
N5009—Hamilton Beach Mixer, 3 test speeds, 230-volt, 60-Hz. No-load
or oil base drilling fluid&and are available for 115 or 230- test speeds are 18,000,16,000 and 13,000 rpm. Complete with
volts use. Powerstats are frequently used to provide an stainless steel mixing cup and automatic starting switch.
extended mixing speed range. N5005—Hamilton Beach Mixer, 3 spindles, 3 speeds, 115-volt, 60-Hz.
No-load test speeds are 18,000,16,000 and 13,000 rpm.
10275—FANN Laboratory Mixer, two test speeds, 115-volt, 60-Hz. No- N5020—Multimixer, 115-volt, 60-Hz. 5 spindles have wavey bottom
load test speeds are 15,000 and 11,000 rpm. Complete with agitator and operate at no-load speed of about 11,500 rpm.
chrome plated motor housing, lab mixer stand, and FANN Cups and sound-resistant chamber should be ordered sepa-
standard mud impeller blade for mixing water base and oil base rately. 14h x 18w x 22d inch (356 x 457 x 550 mm). Net weight
drilling fluids. 71 lb(32kg).
35301—FANN Laboratory Mixer, two test speeds, 230-volt, 60-Hz N5025—Multimixer, 5 spindle, 230-volt, 50-Hz, without containers, modi-
10104—Powerstats, 115-volts fied for spindle speed of 11,000 ± 300 rpm, per API RP 13А
35325—Powerstats, 230-volts 10822—Sound-Resistant Chamber for Multimixer
N5001 —Stainless Steel Mixer Cup for use with Hamilton Beach mixers
or Multimixers.
N5003—Impeller Blade for Hamilton Beach Mixers
HIGH SPEED N5022—Impeller Blades for Multi-Mixer
BLENDERS
High Speed
blenders are also
supplied for general
purpose mixing
use in laboratories.
A lightweight, multi-
speed Hamilton
Beach blender
with a plastic No. N5501-Mini-Cup
housing and mixing
container is suitable for field use. The Waring Blendor with No. N5301 —
its high shear mixing impeller is specified in several API Mixer
test procedures for preparation of samples. N5201 —Mixer, 115-volt AC-DC, complete with spring clip for direct
attachment to No. 20200 1,000 ml measuring cup
11349—Hamilton Beach Blender, 7 test speeds, 115-volt, 60-Hz N5301 —Mixer, 12-volt DC, complete with spring clip for direct attach-
L4201—Waring Blendor, Single Speed, 115-volt, 60-Hz ment to No. 20200 1,000 ml measuring cup
10274—Waring Blendor, 2 speeds, 115-volt, 60-Hz
11480—Waring Blendor, 2 speeds, 230-volt, 60-Hz
N5515—Waring Blendor, 7 speeds, 115-volt, 60-Hz
10123—Blade replacement for Waring Blendor
10262—Lid for Waring Blendor Mixer Container
10151 —Glass Container for Waring Blendor
N5501—Mini-Cup, 12-37 ml for Waring Blendor
N5502—Mini-Cup, 37-50 ml for Waring Blendor

48
N5400—BAROID PORTABLE LAB N5265—HIGH SHEAR MIXER
MIXING TANK The Baroid High Shear Mixer utilizes a patented mix-
This tank is a convenient mixing facility, providing up to 50 ing head which pumps material into the hollow mixing
gallons of a homogeneous, thoroughly hydrated and chamber and outward through the chamber openings.
mixed mud sample for training and testing labs requiring The mixing head's blades are designed to draft mate-
uniform sample series. rial from above and below the mixing head and pull it
The mixing action is accomplished through a mechan- into the chamber. The suction of the blades and flow
ical stirrer and a centrifugal pump circulating system. The through the chamber provide a more homogeneous
addition of clays, weight materials and chemicals is material mix compared to other mixers which rely
simple and convenient. Samples can be easily obtained exclusively on centrifugal force. The High Shear Mixer
from a spigot. attains a higher shear in less time and maintains a
The Baroid tank is completely portable and requires no homogeneous material mix without shear deprecia-
permanent plumbing or electrical modification. tion. The mixing head is easily disassembled, cleaned
and reassembled. The high shear mixing head and
Specifications: shaft can be provided separately to replace the exist-
Capacity 50 gallons or 1.2 barrels ing blades and shafts on suitable mixing motors. The
Construction Stainless Steel
Mechanical
mixing motor is mounted on a durable, stable stand
Mixer 1/3 HP, 110V AC, 60-Hz, Variable Speed which will not vibrate during mixing.
Centrifugal 1/4 HP, 110VAC, 60-Hz, 20-gallon minimum.
Pump Controlled circulating pressure and drain system. Specifications:
Weight 200 Ib Motor 115V AC/DC, lOOOrpm, 1 hp
Stand Steel square bar stock with height adjustment
pole welded to frame
Mixing Shaft and
Mixing Head All stainless steel
Material Capacity 30 gallons @ 18 Ib/gallon material weight
No. N5400—Portable
Lab Mixing Tank

N5265—High Shear Mixer complete with stainless steel stand and


patented mixing head.
INCLUDES:
E5009—Mixing Motor
N5262—Top Blade
N5263—Mixing Cage
N5264—Bottom Blade
N5266—Stand for High Shear Mixer
N5267—Motor Mount
ACCESSORIES:
N5268—7/16" Shaft for High Shear Mixer
N5261—1/2" Shaft for High Shear Mixer

49
MAGNETIC STIRRERS BALANCE
N5251—The Heated Magnetic Stirrer features solid state speed N0000—Balance, portable prescription, with fine scale reading in
control which allows smooth and continuous variations of .01 gram divisions from 0.0 to 0.5 and coarse scale reading
rpm for accurate blending and stirring. Speeds range from in .5 gram divisions from 0 to 50 grams.
50 to 1,500 rpm and a thermostatic temperature control Total capacity 50.5 grams. Sensitivity .01 gram.
allows quick heat-up to 700°F. Stainless steel case is 5" x 9" x 1-1/2" with beam and pan
N5253—The Baroid Portable Magnetic Stirrer is a new concept in tucked inside for rugged portability.
field mud testing. Designed to replace hand operations,
this unit will give over 50 hours of consistent operation up
to 700 rpm. The unit is powered by two "C" size batteries.
11335—The Stir-Light Magnetic Stirrer has a fluorescent illuminat-
ed work surface and speed selection from 600 to 1200
rpm.
N5257—Stirring Bar Magnetic 3/8" x 1"
N5255—Stirring Bar Kit
N5256—Stirring Bar Retriever
N3701—Titration Dish

No. N5251-Heated No. N5253—Portable THERMOMETERS


Magnetic Stirrer Magnetic Stirrer N7900—Thermometer, Dial, All-Metal
5-in. stem, 0 to 220°F 2° Divisions
N7901—Thermometer, Dial, All-Metal
5-in. stem, 50 to 350°F, 2° Divisions
N7902—Thermometer, Dial, All-Metal
8-in. stem, 50to500°F; 5° Divisions
N8200—Thermometer, Precision 0 to
300°F 2° Divisions, glass, yellow back
N8201—Thermometer, 40 to 110° R for
Resistivity Meter Electrode
N8202—Digital Thermometer, 9-volt
battery operated, Temperature
CENTRIFUGES Range -30°F(-34°C) to
83087—Hand Crank Centrifuge + 1,999°F(1,093°C)
83089—Centrifuge Tube, Clinical, Corning #8360 N8203—Probe for Digital
83086—12-Volt Centrifuge _ Thermometer
N3212—Centrifuge Tube, 12.5ml N8208—Vinyl Case for Digital
N3220—Centrifuge Tube, 100ml Thermometer

L6150—HOTPLATE
L6150—Hotplate, Thermolyne with thermostat, 300-watt, 115-volt AC,
31/2-in. diameter, 1 VHb cast aluminum top. Will heat to 500°F in
41/z minutes.
L6155—Hotplate, Thermolyne with thermostat, 300-watt, 230-volt

No. 83087—Hand Crank Centrifuge

50
Supplies for Instruments, Test Kits and Mud Laboratories
Baroid maintains a large inventory of labware, consum- BRUSHES:
able supplies and reagents that are used in the various N1300—Large, wood handle, 3 x 12-inches
N1400—Test tube, 1Уг x 11-inches
instruments, test kits, and mud laboratories that we N1401—Test tube, 1/2 x8-inches
supply. This section is an alphabetical listing of all glass N1402—For 50 ml retort, 11 Уг-inches
and plastic labware, special tools and fixtures, and all N1500—Pipette, 17-inches
consumable supplies. A separate alphabetical listing of
reagents and chemicals is given in this section. BURETTE:
Please let us know your requirements for items that are N1900—Automatic, 10 ml
83101—Automatic, 10 ml
not covered in this catalog since we are able to supply 35309—Acrylic, 25 ml
customized concentrations and/or quantities of materials
on special orders. CUPS:
20211—500 ml, measuring, stainless steel
BATTERIES: 20212—1000 ml, measuring, stainless steel
33041 —1.5-volt, type AA, alkaline 20200—1000 ml, measuring, plastic, yellow
33045—4.2-volt 20201—1000 ml, measuring, plastic, white
L4423—8.4-VOlt 20213—2000 ml, measuring, stainless steel
L4409—9-volt, alkaline 20220—EP/Lubricity Tester, stainless steel
L4422—22.5-volt 28055—Rheometer, stainless steel
30929—Viscometer, stainless steel
BEAKERS:
60105—50 ml, Pyrex FILTER PAPER:
83125—50 ml, tripour, plastic 11502—181/2 cm diameter, fluted, 100 per box
60100—100 ml, plastic N8600—121/2 cm diameter, 100 per box
10119—150ml, Pyrex L;::q N8700—31/2-inch diameter, for API filter press, 100 per box
N8745—47 mm diameter, millipore, 0.45 micron, 25 per box
60103—250ml, Pyrex
10486—400ml, Pyrex
31274-^tOO ml, plastic
О-Е-1
I 1Я-
N8747—31/2-inch diameter, millipore, 0.45 micron, 10 per box
N8800—21/2-inch diameter, for HPHT and 1/2 Area Filter Press, 100 per
60260—600 ml, stainless steel box
31760—1000 ml, stainless steel N8802—21/2-inch diameter, glass fiber, back up for Filter paper, 50 per
box
BOOKS AND MANUALS: N8805—2'/2-inch diameter, extra strength, for sticking tester, 100 per
box
MT1000—Manual of Drilling Fluids Technology
N8806—70 mm x 90 mm, for Capillary Suction Timer, 170 per box
E1050—Drilling Mud Handbook N8804—2 Vz-inch diameter, stainless steel filler, dynalloy X-5, each
10125—"Composition and Properties of Oil Well Drilling Fluids", by
Gray and Darley, 1980
E1009—"Apparatus and Procedure for the Field Testing of Drilling FLASKS:
Muds", Section 900 N4540—25 to 40 ml graduations, for Baroid 50 ml retort
E1041—Testing Equipment Catalog N4550—35 to 50 ml graduations, for Baroid 50 ml retort
83106—25 ml, volumetric
N4541—100ml, volumetric
BOTTLES: 10230—125ml, Erlenmeyer
31454—y2 oz, dropper bottle, plastic
N4525—250 ml, Erlenmeyer
N4600—1 oz, with dropper cap, poly
11356—250 ml, volumetric, with stopper
N0870—1 oz, french square, wide mouth, glass
10524—500ml, Erlenmeyer
N0712—30 ml, serum vial, with seal, glass
N4535—Le Chatelier, for specific gravity
N4601—2 oz, oval, with dropper cap, poly
N0871 —2 oz, french square, wide mouth, glass
N1000—2 oz, with dropper, tinted, glass FUNNELS:
N4602—4 oz, boston round, poly 11507—Analytical, plastic, 100 mm
N4622—4 oz, narrow mouth, brown, poly 20100—Viscometer, marsh, yellow
N4632—4 oz, wide mouth, poly 20101—Viscometer, marsh, white
35326—4 oz, square, wide mouth, glass 40201 —Plastic, for sand content
10137—6 oz, narrow mouth, poly 44007—For Capillary Suction Timer
10138—6 oz, round, wide mouth, poly N4201—Plastic, 3-inch
N0806—6 oz, prescription, glass, 48 per carton N4221 —Separatory, 125 ml, glass, with stopcock and stopper
N4603—8 oz, boston round, poly N4222—Separatory, 500 ml, glass, with stopcock and stopper
N4624—8 oz, narrow mouth, brown, poly
N0810—8 oz, round, glass GLASSWARE, OTHER:
N0877—8 oz, boston round, narrow mouth, amber, glass 83089—Centrifuge tube, 10 ml, 0.1 ml divisions
N4604—16 oz, boston round, poly N3212—Centrifuge tube, API, 12.5 ml, 100%
N4626—16 oz, round, narrow mouth, brown, poly N3220—Centrifuge tube, 100 ml, with stopper
N4605—32 oz, boston round, poly 10802—Receiver tube, for FANN HPHT Filter Press
N4627—32 oz, narrow mouth, brown, poly 40300—Sand Content Tube, graduated 0-20%
N4636—32 oz, wide mouth, poly 63208—Test tube, culture, 20 ml, 16 x 125 mm
A6001 —32 oz, round, wide mouth, poly 11338—Test tube, 25 x 150 mm
N4610—1000 ml, round, poly, for pH meter 11339—Test tube, 38 x 200 mm
N4608—1 gal, round, white, poly 10251—Hydrometer Cylinder, 250ml
10510—1 gal, amber, high density poly 55204—Dispersion Tube
N4649—5 gal, with spigot, poly J3012—Receiver Tube 10 ml, for Oil Mud Retort
40002—500 ml, wash bottle, with delivery tube, poly J3013—Receiver Tube 20 ml, for Oil Mud Retort

51
CYLINDERS: 31682—2-7/8 x 3 x 1/16-inch, Fluorocarbon
31377—3x3-1/4x 1/8-inch, Nitrile
Graduated cylinders are used in a number of different 11512—3x3-1/4 x 1/8-inch, Fluorocarbon
instruments and test kits. Cylinders which have the same 30414—3-1/4x3-1/2x 1/8-inch, Nitrile
volumetric capacity are offered with different types of L4545—3-5/8 x 4 x 3/16-inch, Nitrile
calibration so that the user may select equipment either to L4579—3-5/8 x 4 x 3/16-inch, Teflon
precisely deliver or to contain the specified volumes. 31191—3-5/8 x 3-7/8 x 1/8-inch, Nitrile
L4638—3-1/2 x 3-3/4 x 1/8-inch, Nitrile
Because some liquid is always retained on the walls of 30735—3-3/4 x 4 x 1/8-inch, Fluorocarbon
such glassware, the user must consider whether the test L4620—4 x 4-1/4 x 1/8-inch, Nitrile
requires an exact delivery of a specified volume of fluid or
whether the amount of fluid collected or contained must OIL AND LUBRICANTS:
be precisely measured. 31571 —Oil, heater bath, 32 oz
31572—Oil, viscometer head, bear trac, 32 oz
In test procedures where the graduated cylinders are L4026—Lubriseal, stopcock grease
used as receivers, such as in filtration tests and in API 87009—Lubricant, high temperature, 1 oz
fluid loss tests, or in retort analysis for the liquid and solid
content of a drilling fluid, the glassware is precisely cali- PIPETTES:
brated "To Contain" the indicated amounts at 20°C. Such We supply two types of reusable glass pipettes, serolog-
glassware is identified as "TC at 20°C". ical and volumetric.
Other test procedures require that the amount of fluid
which is dispensed must be precise and these graduated Graduated or Measuring Pipettes are also called serologi-
cylinders are calibrated "To Deliver" the indicated cal pipettes and are, in effect, a small burette. They are
amounts at 20°C by allowing for any hold-up on the walls used to deliver, more or less precisely, volumes of solu-
of the glass. Such glassware is identified as "TD at 20°C". tions or reagents. They are not used for the measurement
A test procedure should state the required precision . of variable volumes with the same degree of precision as
and/or calibration so that the user can select the optimum a laboratory burette. They are calibrated "To Deliver" at
type of graduated cylinder. Some field test procedures 20°C. Some graduated pipettes are calibrated "To
have not previously required such consideration of preci- Deliver/Blow Out". After being allowed to drain, the drop
sion in the selection of glassware. Advances in drilling that remains in the tip is blown out. These pipettes are
fluids technology have dictated a need for greater test distinguished by two frosted bands near the mouthpiece.
precision, even in field testing situations. For test proce-
dures where the graduated cylinder is only used as a con- Volumetric or Transfer Pipettes have only one graduation
tainer, as for the hydrometer test, precise calibration is not mark and are used to deliver an exact volume of solution.
indicated so that the most economical labware can be The mark is placed on the upper stem which has a small
supplied. diameter. They are calibrated to deliver at 20°C. The
pipette is allowed to drain naturally in such a manner that
GRADUATED CYLINDERS: the liquid delivered does not spatter. The top of the pipette
N3101—5ml, glass, 0.1 ml divisions, "TD" to deliver at 20°C is held against the inner wall of the receiving vessel for
N3100—10 ml, glass, 0.2 ml divisions, "TD" to deliver at 20°C
35334—10 ml, glass, 0.1 ml divisions, "TC" to contain at 20°C several seconds. The last portion of the liquid remains in
10161—20 ml, glass, calibrated 0 to 100%, "TC" to contain at 20°C the pipette and is not blown out. Pipettes are both cali-
N3000—25 ml, glass, 0.2 ml divisions, "TC" to contain at 20°C brated and used in this manner. Graduation: Some
N2900—50 ml, glass, 1.0 ml divisions, "TD" to deliver at 20°C pipettes are calibrated "To Deliver/Blow Out". These must
35336—50 ml, glass, 1.0 ml divisions, "TC" to contain at 20°C
N2800—100 ml, glass, 1.0 ml divisions, "TD" to deliver at 20°C
be allowed to drain. Then the drop that remains in the tip is
11716—250 ml, plastic, 2.0 ml divisions, "TC" to contain at 20°C blown out. These pipettes are distinguished by two frosted
J3003—1000 ml, plastic, 10.0 ml divisions, "TC" to contain at 20°C bands near the mouthpiece.
O-RINGS PIPETTES:
L4500—1/8 x 1/4 x 1/16-inch, Nitrile
L4502—5/32 x 9/32 x 1/16-inch, Nitrile Catalog No. Capacity Graduations Type
35444—5/32 x 9/32 x 1/16-inch, Fluorocarbon N5800 0.1 ml .01 ml Serological
L4503—3/16x5/16x1/16-inch, Nitrile N5801 0.2ml .01ml Serological
30564—7/32 x 11/32 x 1/16-inch, Neoprene N5900 1.0ml .01 ml Serological
31616—7/32 x 11/32 x 1/16-inch, Nitrile 10305 2.0ml 0.10ml Serological
L4505—1/4x3/8 x 1/16-inch, Nitrile N6000 5.0ml 0.10ml Serological
L4506—5/16 x 7/16 x 1/16-inch, Nitrile N6100 10.0ml 0.10ml Serological
30737—5/16x7/16 x 1/16-inch, Fluorocarbon 11504 25.0 ml Volumetric
L4507—3/8 x 1/2 x 1/16-inch, Nitrile 63206 1.0ml Dropper
30736—7/16x9/16 x 1/16-inch, Fluorocarbon
L4510—1 /2 x 1 /16 x 3/32-inch, Nitrile
30138—1/2x5/8 x 1/16-inch, Nitrile
L4511—9/16 x 3/4 x 3/32-inch, Nitrile
31193—9/16 x 11/16 x 1/16-inch, Nitrile
L4514—3/4 x 5/16 x 3/32-inch, Nitrile
L4519—1 x 1-1/4 x 1/8-inch, Nitrile
L4513—11/16 x 7/8 x 1/16-inch, Nitrile
30738—1-1/4 x 1-1/2 x 1/8-inch, Fluorocarbon SPATULAS:
L4675—1-5/16 x 1-7/16 x 1/16-inch, Nitrile 10337—Stainless steel blade, 3-inch
L4676—1-3/8 x 1-1/2 x 1/16-inch, Nitrile N7300—Stainless steel blade, 4-inch
L4525—1-3/8 x 1-5/8 x 1/8-inch, Nitrile' N7200—Stainless steel blade, 6-inch
L4674—1-5/8 x 1-3/4 x 1/16-inch, Nitrile N7100—Stainless steel blade, 8-inch
L4606—2-1/4 x 2-1/2 x 1/8-inch, Nitrile 87004—For Baroid retort
10798—2-5/16 x 2-1 /2 x 3/32-inch, Fluorocarbon 31378—Hyde, for FANN Ministill, 31/Hnch
10336—Micro, 51/2-inch
52
STOPPERS: REAGENTS:
J4016—Rubber, solid, No. 6 60303—Buffer Solution, pH4, 1 oz
N1903—Rubber, two holes, No. 8 60503—Buffer Solution, pH4, 8 oz
11340—Cork, solid, No. 10 60301—Buffer Solution, pH7, 1 oz
31992—Rubber, solid, No. 10 60501—Buffer Solution, pH7, 8 oz
11341—Cork, solid, No. 20 60300—Buffer Solution, pH7, 16 oz
60302—Buffer Solution, pH10, 1 oz
SYRINGES: (Note: 1 cm3 = 1 cc = 1 ml) 60401—Buffer Solution, pH10, 2 oz
35109—With needle, 1 cc 60502—Buffer Solution, pH10, 8 oz
10344—Hypodermic, glass, Luer-lock tip, 2 cc 60400—Buffer Solution, pH10, 16 oz
N3303—Glass tip, 2 cc 52600—Calcium Carbonate Powder, 2 oz
N3332—Disposable, plastic, with needle, 3 cc 52610—Calcium Chloride Solution, 2 oz
N3304—Glass tip, 5 cc 11302—Calcium Chloride Solution .295, 100 ml
N3324—Metal, veterinary, Luer-lock tip, 5 cc 52620—Calcium Chloride Powder, 4 oz
N3334—Disposable, plastic, with needle, 10 cc 51800—Calcium Indicator Solution, 2 oz
N3306—Glass, Luer-lock tip, 10 cc 51801—Calcium Indicator Solution, 8 oz
11483—Glass, Luer-lock tip, 30 cc 11300—Calcium Nitrate Solution .505, 100 ml
11700—Luer slip tip, 60 cc 35323—Calcium Sulfate Anhydrous, 2 oz
N3325—Metal, veterinary, 10 cc 10241—Calcium Titration Solution I, 2 oz
N3308—Glass tip, 50 cc 11607—Calcium Titration Solution 1,16 oz
N3314—Glass tip, 5 cc 10660—Calcium Titration Solution II, 2 oz
11608—Calcium Titration Solution II, 16 oz
THERMOMETERS: 50731—Calcium Versenate Buffer Solution 1N, 2 oz
N8201—40 to 110°F, 2° divisions, for Baroid Resistivity Meter 11295—Calgon® Powder, 40 gm
N7903—30 to 120°F, 1° divisions, 12-inch length, for Hydrometers 50744—Calver» II Indicator Powder, 10 gm
10362—0 to 220°F, 1° divisions, 6-inch length, pocket, metal holder 52755—Chlorthene, 1 qt
N7900—0 to 220°F, 2° divisions, dial with 5-inch stem, metal 64057—Copper Sulfate Powder, 757 gm
11342—77 to 221 °F, 0.5° divisions, glass for ASTM Aniline Point 35257—Creosol Red Indicator Solution, 2 oz
N8200—0 to 300°F, 2° divisions, glass 52912—Deionized Water, 8 oz
N7901—50 to 350°F, 2° divisions, dial with 5-inch stem, metal 42550—Dispersant Solution, 1 qt
N7902—50 to 500°F, 5° divisions, dial with 8-inch stem, metal 42560—Dye for Photometer, 1 gal
10810—50 to 500°F, 4-inch stem, 1-3/4" face, for FANN HPHT Press 53344—Ethylene Glycol, 2 oz
N8202—30°F (-34°C) to 1999°F (1093°C), digital, 9-volt battery 53675—Exosol - Isopropyl 75:25, 8 oz
operated, with probe 53676—Exosol - Isopropyl 75:25, 1 gal
35306—Glacial Acetic Acid, 4 oz
52463—Hydrochloric Acid .1N, 8 oz
REAGENTS: 52473—Hydrochloric Acid 10%, 8 oz
11433—Acetic Acid 5%, 32 oz
52451—Hydrochloric Acid Concentrated, 2 oz
11560—Acetic Acid Concentrated, 16 oz
52455—Hydrochloric Acid Concentrated, 32 oz
31434—Aerosol Solution, 1/2 oz
35311—Hydrochloric Acid 0.5N, 2 oz
10481—Aerosol Solution, 2 oz
52483—Hydrochloric Acid N/50, 8 oz
55115—AKTAFLO-E, 8 oz
50761—Hydrogen Peroxide 3%, 2 oz
55116—AKTAFLO-E, 16 oz
50763—Hydrogen Peroxide 3%, 8 oz
52737—Alcohol Isopropyl, 1 gal
51701—IMPERMEX Indicator Solution, 8 oz
11365—Alcohol Isopropyl - Xylene Mixture, 16 oz
50756—Iron Buffer Solution, 2 oz
11366—Alcohol Isopropyl - Xylene Mixture, 1 gal
50758—Iron Buffer Solution, 8 oz
63201—ALDACIDE Test Solution "A", 2 oz
50751—Iron Indicator Solution, 2 oz
63202—ALDACIDE Test Solution "B", 2 oz
50753—Iron Indicator Solution, 8 oz
63203—ALDACIDE Test Solution "C", 2 oz
63651—Iron Sulfide Detection Solution, 2 oz
63204—ALDACIDE Test Solution "D", 2 oz
10761—Liquid Steel Wool, 2 oz
35258—Aluminum Chloride 0.1 M, 8 oz
51943—Magnesium Chloride 20 EPM, 8 oz
63643—Amine Buffer Solution, 2 oz
10424—Manver Indicator Solution, 2 oz
63641—Amine Indicator Solution, 2 oz
51600—Methyl Orange Indicator Solution, 2 oz
11610—Ammonium Fluoride 10%, 32 oz
51602—Methyl Orange Indicator Solution, 8 oz
11612—Ammonium Hydroxide, 16oz
11371—Methyl Orange Bromocreosol Green Indicator Solution, 2 oz
51500—Ammonium Persulfate Powder, 10 gm
51601—Methyl Orange Indicator Solution with AF, 2 oz
11301—Ammonium Sulfate .800, 100 ml
51603—Methyl Orange Indicator Solution with AF, 8 oz
64102—Aniline Reagent Grade, 2 oz
51621—Methyl Purple Solution, 2 oz
52435—Ascorbic Acid, 10 gm
42513—Methylene Blue Solution .01 ME, 8 oz
10416—Barium Chloride 10%, 2 oz
42514—Methylene Blue Solution .01 ME, 16 oz
11376—Barium Chloride 10%, 16 oz
42515—Methylene Blue Solution .01 ME, 32 oz
65606—Barium Chloride Saturated, 4 oz
42517—Methylene Blue Solution .01 ME, 1 gal
65608—Barium Chloride Saturated, 8 oz
42510—Methylene Blue Solution .01 ME, 5 gal
51934—Barium Chloride Standard 50 EPM, 16 oz
42506—Methylene Blue Solution .01 ME with AF, 8 oz
51353—Boric Acid 2% by Volume, 16 oz
42507—Methylene Blue Solution .01 ME with AF, 16 oz
51631—Bromocresol Green-Methyl Red Ind 1:2, 2 oz
42509—Methylene Blue Solution .01 ME with AF, 1 gal
51632—Bromocresol Green-Methyl Red Ind 1:2, 4 oz

53
REAGENTS: REAGENTS:
42523—Methylene Blue Solution 4.5 gm/l, 8 oz 51325—Sulfuric Acid N/10, 4 oz
42524—Methylene Blue Solution 4.5 gm/l, 16 oz 51308—Sulfuric Acid N/10, 8 oz
42527—Methylene Blue Solution 4.5 gm/l, 1 gal 51301—Sulfuric Acid N/10, 16oz
52401—Nitric Acid .1N, 8 oz 51307—Sulfuric Acid N/10 with AF, 2 oz
52402—Nitric Acid 1 N, 8 oz 51309—Sulfuric Acid N/10 with AF, 16 oz
52400—Nitric Acid 3N, 8 oz 51323—Sulfuric Acid N/50, 4 oz
51200—Phenolphthalein Indicator Solution, 2 oz 51306—Sulfuric Acid N/50, 8 oz
51202—Phenolphthalein Indicator Solution, 8 oz 51304—Sulfuric Acid N/50, 16 oz
60900—Potassium Chloride Saturated, 4 oz 51305—Sulfuric Acid N/50, 32 oz
51950—Potassium Chloride Standard, 4 oz 51324—Sulfuric Acid N/50 with AF, 4 oz
51000—Potassium Chromate Indicator Solution, 2 oz 51318—Sulfuric Acid N/50 with AF, 8 oz
51002—Potassium Chromate Indicator Solution, 8 oz 51317—Sulfuric Acid N/50 with AF, 32 oz
51001—Potassium Chromate Indicator Solution with AF, 2 oz 51900—Sulfate Indicator Solution, 2 oz
51003—Potassium Chromate Indicator Solution with AF, 8 oz 51901—Sulfate Indicator Solution, 8 oz
64026—Potassium Iodide lodate, 8 oz 55043—Surfactant Reagent #1, 2 oz
60914—Potassium Ion Buffer Solution, 16 oz 50700—SURFLO W-300 Defoaming Solution, 2 oz
60916—Potassium Ion Indicator Solution, 2 oz 64018—Thiosulfate Solution .1N, 16 oz
60912—Potassium Ion Titration Solution (QAS), 32 oz 51220—Thymophthalein Indicator Solution, 2 oz
60910—Potassium Ion Titration Solution (STPB), 32 oz 51223—Thymophthalein Indicator Solution, 8 oz
11499—Quaternary Ammonium Salt Solution, 4 oz 50705—Versenate Hardness Buffer Solution, 2 oz
50718—SDI Defoamer, 8 oz 50717—Versenate Hardness Buffer Solution, 4 oz
52213—Silver Nitrate Solution .0282 N, .001 g/ml, 4 oz 50708—Versenate Hardness Buffer Solution, 8 oz
52200—Silver Nitrate Solution .0282 N, .001 g/ml, 8 oz 50703—Versenate Hardness Indicator Solution, (Calmagite®), 2 oz
52201—Silver Nitrate Solution .0282 N, .001 g/ml, 16 oz 50706—Versenate Hardness Indicator Solution with AF, 2 oz
52202—Silver Nitrate Solution .0282 N, .001 g/ml, 32 oz 50707—Versenate Hardness Titration Solution (EDTA) 2 EPM, 4 oz
52203—Silver Nitrate Solution .0282 N w/AF, .001 g/ml, 8 oz 50709—Versenate Hardness Titration Solution (EDTA) 2 EPM, 8 oz
52307—Silver Nitrate Solution .141 N, .005 g/ml, 8 oz 50714—Versenate Hardness Titration Solution (EDTA) 2 EPM AF, 8 oz
52306—Silver Nitrate Solution .282 N, .01 g/ml, 4 oz 50702—Versenate Hardness Titration Solution (EDTA) 2 EPM, 16 oz
52300—Silver Nitrate Solution .282 N, .01 g/ml, 8 oz 50701—Versenate Hardness Titration Solution (EDTA) 2 EPM AF, 16 oz
52301—Silver Nitrate Solution .282 N, .01 g/ml, 16 oz 50711—Versenate Hardness Titration Solution (EDTA) 20 EPM, 4 oz
52302—Silver Nitrate Solution .282 N, .01 g/ml, 32 oz 50715—Versenate Hardness Titration Solution (EDTA) 20 EPM, 8 oz
52303—Silver Nitrate Solution .282 N 2/AF, .01 g/ml, 8 oz 50713—Versenate Hardness Titration Solution (EDTA) 20 EPM, 16 oz
52304—Silver Nitrate Solution .282 N 2/AF, .01 g/ml, 16 oz 10445—Versenate Hardness Titration Solution (EDTA) 20 EPM, 32 oz
52305—Silver Nitrate Solution .282 N 2/AF, .01 g/ml, 32 oz 50720—Versenate Hardness Titration Solution (EDTA) 20 EPM, 5 gal
52900—SLIK 5 (Concentrate), 8 oz 50716—Versenate Hardness Titration Solution (EDTA) 20 EPM AF, 4 oz
51402—Sodium Chloride 10,000 PPM, 4 oz 50712—Versenate Hardness Titration Solution (EDTA) 20 EPM AF, 8 oz
63501—Sodium Chromate Test "A" Solution, 2 oz 50710—Versenate Hardness Titration Solution (EDTA) 20 EPM AF, 16 oz
63502—Sodium Chromate Test "B" Solution, 2 oz 11348—Versenate Hardness Titration Solution (EDTA) 200 EPM, 16 oz
63503—Sodium Chromate Test "C" Solution, 2 oz 52712—Water Distilled, 4 oz
55169—Sodium Hydroxide 5.0N, 4 oz 52713—Water Distilled, 8 oz
11293—Sodium Hydroxide 8N, 4 oz 52714—Water Distilled, 16oz
52100—Sodium Hydroxide N/10, 2 oz 52715—Water Distilled, 32 oz
52103—Sodium Hydroxide N/10, 4 oz 52717—Water Distilled, 1 gal
52102—Sodium Hydroxide N/10, 8 oz 52501—Wetting Agent, 1 oz
52101—Sodium Hydroxide N/10, 16 oz 52502—Wetting Agent with AF, 1 oz
55168—Sodium Hydroxide 15%, 4 oz 11234—Zinc Chloride Solution .100, 100 ml
11500—Sodium Hydroxide 20%, 4 oz
35307—Sodium Hypochlorite, 4 oz
52121—Sodium Perchlorate, 8 oz AF = Antifreeze
52120—Sodium Perchlorate, 16 oz
64071—Sodium Sulfide 10% Solution, 30 cc
10331—Sodium Sulfite Powder, 2 oz
11498—Sodium Tetraphenol Boron Solution, 4 oz
52001—Standard Soap Solution, 32 oz
64016—Sulfide Ion Buffer Solution, 2 oz
64011—Sulfide Ion Indicator Solution, 2 oz
64001—Sulfide Ion Test "A" Solution, 2 oz
64002—Sulfide Ion Test "B" Solution, 2 oz
64003—Sulfide Ion Test "C" Solution, 2 oz
64023—Sulfide Ion Titration Solution, 8 oz
51331—Sulfuric Acid 13%, 2 oz
51332—Sulfuric Acid 5N, 4 oz
51333—Sulfuric Acid 5N, 8 oz
51334—Sulfuric Acid 5N, 16 oz
51335—Sulfuric Acid 5N, 32 oz

54
fanri

Available From:

Fann Instrument Company


P.O. Box 4350
ТЕ
TESTING EQUIPMENT NEDERLAND BV
Houston, Texas 77210 U.S.A.
Telephone: (281) 871-4482 Raadhuisstraat 1 - 1746 BE Dirkshorn
Toll Free: 1 -800-347-0450
Fax:(281)871-4358 Holland
Internet Web Page: www.fann.com
Tel.+31(0)224-551090 - Fax+31(0)224-551459

We Accept J-TJTJWU т U.&.F\.


Fann Instrument Company

Vous aimerez peut-être aussi