Series
RHP
Humidity/Temperature Transmitter
Passive Temperature Outputs, Sintered Filter Options
Duct Mount OSA (Outside Air)
5-1/8
4-17/32 2-15/64 4-17/32 [130.18]
[115.09] [56.75] [115.09]

3-1/8
3-1/8 [79.38]
[79.38]
1-13/64
[30.56]
AIR QUALITY

6-25/32
Ø3/16 [172.09]
[4.76]
MOUNTING
2-11/64 HOLES
[55.17] TYP 4 PLCS 55/64
[21.83]
1/2 NPT
2-33/64
2-9/64 9
[63.90]
[228.60] Sintered Filter Version 5-1/8
[54.37] [130.18] 2-1/4
ø35/64 55/64 [57.15]
ø3-7/16 [21.83]
[ø87.31] [ø13.89]
3-45/64
[94.06]
Humidity/Temperature

(3) 3/16 (4.76) HOLES


EQUALLY SPACED ON A
Transmitters

ø3-11/64 4 115 (104.52) BC 6-25/32


[ø80.57] 2- 9/16 [172.16]
[64.96]

2-11/64 2-41/64
[55.12] [67.07]

The Series RHP Temperature and Humidity Transmitter combine the voltage or SPECIFICATIONS
current humidity transmitter output with a passive temperature thermistor or RTD output. Relative Humidity Range: 0 to 100% RH.
The polymer capacitance humidity sensor is not affected by condensation, fog, high Temperature Range: -40 to 140°F (-40 to 60°C).
humidity, or contaminants. The humidity sensors are available with 2%, 3% or 5% accuracies. Accuracy, RH:
Duct mounted transmitters are available with an optional two-line alpha numeric LCD RHP-2XXX ±2% 10-90% RH @ 25°C;
display. The Series RHP is available with interchangeable filter options as well as RHP-3XXX ±3% 20-80% RH @ 25°C;
replaceable sensors. RHP-5XXX ±5% 20-80% RH @ 25°C.
Accuracy, Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F).
Example RHP 2 D 1 A LCD RHP-2D1A-LCD Accuracy, RTD Temp Sensor: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F).
Series RHP RH/Passive Temperature Hysteresis: ±1%.
Sensor Transmitter Repeatability: ±0.1% typical.
Accuracy 2 2% Accuracy Temperature Limits: -40 to 140°F (-40 to 60°C).
3 3% Accuracy Storage Temperature: -40 to 176°F (-40 to 80°C).
5 5% Accuracy Compensated Temperature Range: -4 to 140°F (-20 to 60°C).
Housing D Duct Mount 4 to 20 mA Loop Powered Models:
Type w/Membrane Filter Power requirements: 10 to 35 VDC;
F Duct Mount Output signal: 4 to 20 mA.
w/Sintered Filter 0-5/10V Output Models:
O OSA (Outside Air) Power requirements: 15 to 35 VDC or 15 to 29 VAC;
S OSA w/Sintered Filter* Output signal: 0 to 10V @ 5 mA max.
R Radiation Shield Response Time: 15 seconds.
RH Output 1 4 to 20mA Electrical Connections: Removable screw terminal block.
2 0 to 10V Conduit Connection:
3 0-5V Duct mount: 1/2˝ NPS;
Temperature 0 None OSA: 1/2˝ (22.3 mm).
Sensor 1 4 to 20mA Drift: <1% RH/year.
2 0 to 10 VDC RH Sensor: Capacitance polymer.
3 0-5V Temperature Sensor:
A 10K @ 25°C Thermistor Types 1, 2, 3: Solid state band gap;
Type III Curves A, B, C: Thermistor;
B 10K @ 25°C Thermistor Curves D, E: Platinum RTD DIN 385.
Type II Enclosure:
C 3K @ 25°C Thermistor Duct mount: PBT;
D 100Ω RTD DIN 385 OSA: Polycarbonate.
E 1KΩ RTD DIN 385 Enclosure Rating: NEMA 4X (IP66) for OSA mount only.
F 20KΩ @ 25°C Thermistor Display: Duct mount only, optional 2-line alpha numeric, 8 characters/line.
Option LCD LCD Display Display Resolution: RH: 0.1%; 0.1°F (0.1°C).
NIST NIST traceable calibration Weight:
certificate (Humidity) Duct mount: .616 lb (.3 kg);
*Model RHRS Radiation Shield is required for sintered filter OSA models. OSA: 1 lb (.45 kg).
Agency Approvals: CE.