Académique Documents
Professionnel Documents
Culture Documents
800
Fin Plate Connection 4. Foundations shall generally be taken down
1000 mm below existing ground level and all
(See Detail 03) excavations to be approved first by the
25
RHSH 60x40x3 10 engineer before concrete blinding is laid
UB 152x89x16
1400
1335
5. Weak Pockets of bearing strata to be dug out
RHSH 60x40x3 and filled with Grade 15 all in concrete mix.
6. Site Engineer to Prepare Trial Mixes for
UB 152x89x16 CHS 457x10 Approval by Engineer.
Fin Plate Connection 7. All Structural Concrete to be Tested for
100
50
Compressive Strength by an Approved
(See Detail 03) 22mm bolt holes laboratory .
SHS 60x40x3 SHS 60x40x3
for M20 8.8 bolts 8. Concrete to receive full time curing preferably
surface curing or equal and approved by the
UB 152x89x16 Engineer.
5 45 45
2800
6000
25
10mm S275 9. Concrete Mixes:
55 Fin Plate · Mass concrete to have a minimum
RHSH 60x40x3 works cube strength of 15N/mm² at
28 days with 40 mm Maximum
welded onto aggregate size.
· Reinforced concrete to have a minimum
vertical chord & works cube strength of 25 N/mm² at 28
horizontal parallel Fin Plate Connection
days with 20 mm maximum Aggregate
size.
5 flange channel (See Detail 03) 580 1400 1400 PFCH 125x65x15 580 4. Reinforcement
· T....denotes High yield bars to be round
and ribbed bars to B.S.4461.
· R ...denotes Mild steel to be round bars
4000 Fin Plate Connection Detail ·
to B.S.4449.
Mesh requirements to comply with the
31
Base plate and anchor bolt 12. All Structural Concrete to be Tested for
259
4360
17. Welding to be metal arc process in
accordance with BS5135 and BS4570 as
appropriate.
18. All fillet welds shall be 6mm minimum and
continuous on all sides by welders approved
65 to BS 4872 Part 1.
Billboard Frame Billboard Frame 19. All load bearing block walls are to be
Front & Back Elevation View Side Elevation View constructed from solid blocks of 5.0 N/mm²
minimum characteristic strength complying
10mm with BS 5628, Part 1, 1978; Structural Use of
Unreinforced Masonry.
10 Thick Stiffener 20. Mortar to conform to designation [III] of table
10 1, BS 5628, Part 1.
CHS 457x10 27 21. Provide masonry anchors every 2 courses
1 using mild steel hoop iron to BS 1243. 1978
18mm Bolt Hole
End Plate Connection
CHS 457x10 member
(Detail 01) Member description Cover max concrete
End Plate Connection agg size grade
10
Blinding 30mm C15
65
REVISIONS.
M16 8.8 Anchor Bolts
10
65
1400
0
End Plate Stiffener Detail
10
12T12-01
Engineer:
10mm Thick Column Base Stiffeners
950
3000
1300
MAKINDYE DIVISION
165
T12-01 KAMPALA
850
ANDREW KASOLA
50mm 2x 16T12-01-200 (T&B) CLIENT
P.O. BOX 710, Kampala
Blinding in 155 160 160 160 160 155
20
Architect: .
Concrete
950
850 1300 850
50
3000
Foundation Reinforcement Details Base Plate Connection Details
Foundation and Base Plate Connection Details
(Detail 02) 100 DATE: DWG.NO. SHEET NO.
SEPT. 2018 KA-02 S.02
Base Plate Stiffener Detail