PROJECT :

CLIENT :

CONTRACTOR:

Design Calculation Report


STRUCTURE SUPPORTING AQUADUCT POWER CHANNEL
Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 2 of 11

Table of Contents
1. Introduction .............................................................................................................................................................................. 3
2. Design Philosophy .................................................................................................................................................................. 3
3. Design Loads ............................................................................................................................................................................. 4
3.1. Dead Loads....................................................................................................................................................................... 4
3.2. Live Loads......................................................................................................................................................................... 4
3.3. Wind Loads ...................................................................................................................................................................... 5
3.4. Seismic Loads (EQ) ...................................................................................................................................................... 6
3.5. Description of the load cases considered in the staad model ............................................................... 6
3.6. Load Combinations ...................................................................................................................................................... 7
3.7. Element material Properties .................................................................................................................................. 7
4. Structural Model ..................................................................................................................................................................... 8
5. Design Calculations..............................................................................................................................................................11
Staad Pro Input & Output File .............................................................................................................................................15
Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 3 of 11

1. Introduction

The aim of the present document is to explain and record the design calculations carried
out for a “STRUCTURE SUPPORTING AQUADUCT POWER CHANNEL”.

The structure is modeled as a truss structure with size so selected to accommodate


1.2x1.7m channel. The height of truss modeled is 1.425 m c/c and width is 1.85m c/c. An
inspection platform is considered above the truss for maintenance and inspection
purpose.

Design of trusses is carried out in accordance with IS 800: 2007. Trusses are modeled as
simply supported trusses and an expansion gap of 20 mm is provided at every column
location.

The tructure is supported on columns which are then supported on RCC columns which
are supported on isolated/combined footings. The design philosophy along with loads &
load combinations considered are explained below:

2. Design Philosophy

The analysis has been done using the structural analysis software STAAD Pro. A 3D model
of the structure has been prepared using the beam elements and a 3D FEM analysis has
been carried ut for different types of loads and their combinations which are explained in
the later part of this report.

Design of steel elements like columns & truss members have been carried out by the
software STAAD Pro SS6 s according to IS 800:2007 (Limit State Design) which has been
explained in detail in the later part of this report.
Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 4 of 11

3. Design Loads

3.1. Dead Loads(DL)

In general, the dead load includes the self-weight of structure, weight of roof sheeting, and
any other loads which are going to act through the whole life of structure

A. The self-weight of the steel members of the housing is considered in the Dead
load case.
B. 6mm thick plate is considered on main deck with a load of 0.47 KN/m2.
C. 6 mm thkchequerred plate is considered on inspection platform with a load of
0.53 KN/m2.
D. Dead weight of 1.2x1.7m rectangular channel with 150 mm thk side wall and
150 mm thk top and bottom slab as 7.5 KN/m2 & 5.625 KN/m for side wall on
dummy beam modeled at its location.

3.2. Live Loads(LL)

Live load on inspection platform is considered as 5 KN/m2 as per IS875:Part-2. Live load
on hand rail is considered as 5.1 KN-m due to a horizontal load of 1.5 KN/m. Impact force
due to change in direction in flow of water at various location applied as 11.12 KN in X
direction and 0.647 KN.

Velocity of water V = 1/n*R^(2/3)*S(1/2)

S = Bed slope (1 in 1000)

R = A/P (A = Wetted area , R = Wetted perimeter)

N = Manning’s co efficient (0.012 for steel pipes)

V = 2.01 m/s

Mass of water at a cross section = 23.55.

Time of Contact of mass of unit section = 0.5 sec


Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 5 of 11

Force acting = m1*v1 = 23.55*0.5 = 11.755 KN (X Direction 11.755*Cos19 = 11.12 KN and


0.647 in Z direction)

3.3. Seismic Loads (EQ)

The seismic loads have been calculated, according to IS-1893 (Part -1), following the next
considerations:

 Zone factor, 0.36 i.e. Zone IV


 Importance factor 1.0
 Response Reduction Factor 4
 Damping ratio 0.05

The seismic response of the structure has been calculated using the STAAD Pro software,
considering as mass source the dead loads of the structure, sheeting etc. Seismic weight is
applied as self-weight & additional load is applied as member weight and floor weight
(weight dead load + 50 % of live load as per IS: 1893 Part 1: 2016.

The nomenclature and description of the specific load patterns used in the calculation
model is defined in STAAD Pro.

3.4. Wind Loads (WL)

The wind loads have been calculated based on the parameters established for the standard
site conditions. For wind loads design code IS-875 (Part – 3) has been followed. The
following parameters have been considered for wind load calculation:

 Basic Design Wind Speed of 39 m/s has been considered as per IS875: Part3.
 Terrain Category: 1
 Class: B
 Probability factor K1=1
 Terrain factor K2=1
 Topographical factor K3=1.06
 Wind directionality factor Kd=0.9
 Area Averaging Factor Ka=1
Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 6 of 11

From the above parameters the design wind speed comes out to be 41.34m/s and wind
pressure comes out to be 1.025 KN/m2.Using area averaging factor Ka=1 and wind
directionality factor Kd=.9 design wind pressure becomes 0.923 KN/m2. The rest of
parameters, such as the roughness factor, external / internal pressure, net pressure, drag
and force coefficients, have been taken from the code and applied subsequently as
Uniformly Distributed Load.
The pressure coefficients has been worked out from table 31 of IS 875 part 3 for 1.9 for
single member. Member force is calculated as (Pd*Cf*Member size) = 0.923*1.9*0.25=
0.438 KN/m.

3.5. Water Load

Load of water flowing through the rectangular channel is considered as 12 KN/m2. Height of water
flowing through rectangular channel is 1.2m = 1.2m*10KN/m3= 12 KN/m2 and an Impact factor of 10 % =
13.2 KN/m2 as a floor load.

3.6. Description of the load cases considered in the staad model

A load case defines how loads are to be applied to the structure, and how the structural
response is to be calculated. The nomenclature and description of the specific load cases
used in the calculation model is as follows:

Table: Load Case Definition


S.
Nomenclature Description
No.
1 DL Self-weight of Structure. Sheeting
2 LL Live load
3 EQX Seismic Response for motion direction X
4 EQZ Seismic Response for motion direction Z
5 EQZ Seismic Response for motion direction Z
6 WL +X Wind Blowing towards +X direction
7 WL +Z Wind Blowing towards +Z direction
8 Water Load Load due to water Flowing through pipe
Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 7 of 11

3.7. Load Combinations

The program design in STAAD. Pro is based on a set of loading combination. The load
combinations are made according to IS 800:2007and IS875: Part 5 for Limit State design
conditions. In total there are 28 load combinations formed for limit state condition each in
accordance with table below:

3.8. Element material Properties

The material properties for the structural steel are as follows:

 Structural Steel, modulus of stability, Es : 200000 MPa


 Steel Yield strength for pipe : 310 MPa
 Structural Steel Ultimate strength : 450 MPa

The material properties for the Grade Class 8.8 Bolts are as follows:

 Structural Steel, modulus of stability, Es : 200000 MPa


 Structural Steel Ultimate strength : 400 MPa
Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 8 of 11

4. Structural Model

The structure has been modeled in 3-dimensions for structural analysis, in which
mathematical model for the real structure is modeled. The same is presented below.

Figure 1 : Overall View


Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 9 of 11

Figure 2:Side View


Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 10 of 11

Figure 3:Front View

Figure 4: Top View


Doc No. :
Rev. No. :0
DESIGN CALCULATION REPORT
Rev. Date : 15 JAN, 2019
Page : 11 of 11

5. Design Calculations

Please refer Annexure –A for Staad Input and output file For Aqua duct Model
Please refer Annexure –B for Foundation Designof “Aqua duct Model”.

6. Results & Discussions

The 3D models have been checked for stress limits and are well within the allowable limits.
For Strength check refers annexure-A.
Annexure A
Job Title:

Client:

Engineer:
STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 17-Dec-18
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 0.055 0 0.275; 2 12.45 0 0.275; 3 24.845 0 0.275; 4 0.055 0 2.025;
5 12.45 0 2.025; 6 24.845 0 2.025; 7 0.055 1.425 0.275; 9 24.845 1.425 0.275;
10 0.055 1.425 2.025; 12 24.845 1.425 2.025; 13 0.055 0 1.15; 14 12.45 0 1.15;
15 24.845 0 1.15; 19 3.13 0 0.275; 20 3.13 0 2.025; 21 6.20499 0 0.275;
22 6.20499 0 2.025; 27 3.13 1.42534 0.275; 28 3.13 1.42534 2.025;
29 6.20499 1.42468 0.275; 30 6.20499 1.42468 2.025; 35 3.13 0 1.15;
36 6.20499 0 1.15; 39 24.845 0 1.65; 40 24.845 0 0.65; 41 24.845 -8.258 1.65;
42 24.845 -8.258 0.65; 43 24.845 -2.528 1.65; 44 24.845 -2.528 0.65;
57 24.845 -4.028 1.65; 58 24.845 -4.028 0.65; 59 24.845 -5.528 1.65;
60 24.845 -5.528 0.65; 61 24.845 -7.028 1.65; 62 24.845 -7.028 0.65;
63 9.27999 0 0.275; 64 9.27999 0 2.025; 65 9.27999 1.42483 0.275;
66 9.27999 1.42483 2.025; 67 9.27999 0 1.15; 69 21.77 0 0.275;
70 21.77 0 2.025; 71 18.695 0 0.275; 72 18.695 0 2.025; 73 21.77 1.42534 0.275;
74 21.77 1.42534 2.025; 75 18.695 1.42468 0.275; 76 18.695 1.42468 2.025;
77 21.77 0 1.15; 78 18.695 0 1.15; 81 15.62 0 0.275; 82 15.62 0 2.025;
83 15.62 1.42483 0.275; 84 15.62 1.42483 2.025; 85 15.62 0 1.15;
88 24.845 -10.258 1.65; 89 24.845 -10.258 0.65; 92 12.355 0 2.025;
93 12.355 1.42499 0.275; 94 12.355 1.42499 2.025; 95 12.355 0 0.275;
96 0.055 1.425 1.15; 97 12.355 0 1.15; 98 12.545 0 2.025;
99 12.545 1.42499 0.275; 100 12.545 1.42499 2.025; 101 12.545 0 0.275;
102 12.545 0 1.15; 103 24.845 1.425 1.15; 104 12.45 0 0.28; 105 12.355 0 0.28;
106 12.45 0 0.46; 107 12.355 0 0.46; 108 12.45 0 0.69; 109 12.355 0 0.69;
110 12.45 0 0.92; 111 12.355 0 0.92; 112 12.355 0 1.35; 113 12.45 0 1.35;
114 12.355 0 1.55; 115 12.45 0 1.55; 116 12.355 0 1.75; 117 12.45 0 1.75;
120 12.545 0 0.28; 121 12.545 0 0.46; 122 12.545 0 0.69; 123 12.545 0 0.92;
124 12.545 0 1.35; 125 12.545 0 1.55; 126 12.545 0 1.75; 127 0.055 0 1.85;
128 24.845 0 1.85; 129 3.13 0 1.85; 130 6.20499 0 1.85; 131 9.27999 0 1.85;
132 21.77 0 1.85; 133 18.695 0 1.85; 134 15.62 0 1.85; 135 12.355 0 1.85;
136 12.545 0 1.85; 147 12.45 -8.258 1.65; 148 12.45 -8.258 0.65;
149 12.45 -2.528 1.65; 150 12.45 -2.528 0.65; 151 12.45 -4.028 1.65;
152 12.45 -4.028 0.65; 153 12.45 -5.528 1.65; 154 12.45 -5.528 0.65;
155 12.45 -7.028 1.65; 156 12.45 -7.028 0.65; 157 12.45 -10.258 1.65;
158 12.45 -10.258 0.65;
MEMBER INCIDENCES
1 1 19; 3 4 20; 8 1 7; 9 95 93; 10 3 9; 11 4 10; 12 92 94; 13 6 12; 14 7 27;
16 10 28; 18 7 96; 20 9 103; 21 13 127; 23 15 39; 27 19 21; 28 20 22; 29 21 63;
30 22 64; 35 27 29; 36 28 30; 37 29 65; 38 30 66; 43 19 27; 44 20 28; 45 21 29;
46 22 30; 51 27 28; 52 29 30; 59 4 28; 60 28 22; 61 22 66; 65 1 27; 66 27 21;
67 21 65; 71 13 35; 73 35 129; 74 35 36; 75 36 130; 76 36 67; 81 1 35;
82 35 22; 83 22 67; 87 39 128; 88 40 15; 89 41 61; 90 42 62; 93 44 3; 94 44 15;
95 43 15; 96 43 6; 115 96 10; 117 103 12; 120 43 44; 121 57 43; 122 58 44;
123 57 58; 124 59 57; 125 60 58; 126 59 60; 127 61 59; 128 62 60; 129 61 62;
130 43 58; 131 58 59; 132 59 62; 133 63 95; 134 64 92; 135 65 93; 136 66 94;
137 67 97; 139 63 65; 140 64 66; 141 65 66; 143 67 131; 147 92 66; 148 95 65;
149 3 69; 150 6 70; 151 9 73; 152 12 74; 153 69 71; 154 70 72; 155 71 81;
156 72 82; 157 73 75; 158 74 76; 159 75 83; 160 76 84; 161 69 73; 162 70 74;
163 71 75; 164 72 76; 165 73 74; 166 75 76; 169 6 74; 170 74 72; 171 72 84;

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.std [18-01-2019 09:32] Page 1 of 6


Job Title:

Client:

Engineer:
172 3 73; 173 73 71; 174 71 83; 175 15 77; 176 77 132; 177 77 78; 178 78 133;
179 78 85; 180 3 77; 181 77 72; 188 81 101; 189 82 98; 190 83 99; 191 84 100;
192 85 102; 194 81 83; 195 82 84; 196 83 84; 198 85 134; 200 98 84; 201 101 83;
203 41 88; 204 42 89; 207 67 95; 208 72 85; 209 85 101; 220 101 99; 221 98 100;
222 93 94; 223 99 100; 225 97 112; 227 102 124; 232 105 107; 234 107 109;
236 109 111; 238 111 97; 241 112 114; 243 114 116; 245 116 135; 250 120 121;
252 121 122; 254 122 123; 256 123 102; 259 124 125; 261 125 126; 263 126 136;
268 7 28; 269 28 29; 270 29 66; 271 66 93; 272 99 84; 273 84 75; 274 75 74;
275 74 9; 276 127 4; 277 128 6; 278 129 20; 279 130 22; 280 131 64; 281 132 70;
282 133 72; 283 134 82; 284 135 92; 285 136 98; 312 147 155; 313 148 156;
314 150 2; 315 150 14; 316 149 14; 317 149 5; 318 149 150; 319 151 149;
320 152 150; 321 151 152; 322 153 151; 323 154 152; 324 153 154; 325 155 153;
326 156 154; 327 155 156; 328 149 152; 329 152 153; 330 153 156; 331 147 157;
332 148 158; 333 1 13; 334 3 40; 335 19 35; 336 21 36; 337 63 67; 338 69 77;
339 71 78; 340 81 85; 341 95 105; 342 101 120;
ELEMENT INCIDENCES SHELL
233 95 2 104 105; 235 105 104 106 107; 237 107 106 108 109;
239 109 108 110 111; 240 111 110 14 97; 242 97 112 113 14; 244 112 114 115 113;
246 114 116 117 115; 248 116 92 5 117; 251 2 104 120 101; 253 104 106 121 120;
255 106 108 122 121; 257 108 110 123 122; 258 110 14 102 123;
260 14 113 124 102; 262 113 115 125 124; 264 115 117 126 125; 266 117 5 98 126;
START GROUP DEFINITION
FLOOR
_G1 14 16 18 20 35 TO 38 51 52 115 117 135 136 141 151 152 157 TO 160 165 -
166 190 191 196 222 223
_G2 1 3 21 23 27 TO 30 71 73 TO 76 87 88 133 134 137 143 149 150 153 TO 156 -
175 TO 179 188 189 192 198 225 227 232 234 236 238 241 243 245 250 252 254 -
256 259 261 263 276 TO 285 333 TO 342
_FACE-Z 3 11 TO 13 16 28 30 36 38 44 46 59 TO 61 134 136 140 147 150 152 154 -
156 158 160 162 164 169 TO 171 189 191 195 200 221
MEMBER
END GROUP DEFINITION
ELEMENT PROPERTY
233 235 237 239 240 242 244 246 248 251 253 255 257 258 260 262 264 -
266 THICKNESS 0.025
DEFINE MATERIAL START
ISOTROPIC STEEL
E 2.05e+008
POISSON 0.3
DENSITY 78.5
ALPHA 1.2e-005
DAMP 0.03
TYPE STEEL
STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
ISOTROPIC CONCRETE
E 2.17185e+007
POISSON 0.17
DENSITY 23.5616
ALPHA 1e-005
DAMP 0.05
TYPE CONCRETE
STRENGTH FCU 27579
END DEFINE MATERIAL
MEMBER PROPERTY TATASTRUCTURA

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.std [18-01-2019 09:32] Page 2 of 6


Job Title:

Client:

Engineer:
1 3 21 23 27 TO 30 71 73 TO 76 87 88 133 134 137 143 149 150 153 TO 156 175 -
176 TO 179 188 189 192 198 225 227 232 234 236 238 241 243 245 250 252 254 -
256 259 261 263 276 TO 285 333 TO 342 TABLE ST 300X150X6.0RHS
8 TO 13 43 TO 46 59 TO 61 65 TO 67 139 140 147 148 161 TO 164 169 TO 174 194 -
195 200 201 220 221 TABLE ST 150X150X6.0SHS
14 16 35 TO 38 135 136 151 152 157 TO 160 190 191 TABLE ST 200X100X6.0RHS
89 90 121 122 124 125 127 128 312 313 319 320 322 323 325 -
326 TABLE ST 250X250X10.0SHS
18 20 93 TO 96 115 117 314 TO 317 TABLE ST 150X150X6.0SHS
MEMBER PROPERTY TATASTRUCTURA
120 123 126 129 318 321 324 327 TABLE ST 50X50X4.5SHS
130 TO 132 328 TO 330 TABLE ST 72X72X4.8SHS
51 52 81 TO 83 141 165 166 180 181 196 207 TO 209 222 223 268 TO 274 -
275 TABLE ST 100X100X6.0SHS
MEMBER PROPERTY TATASTRUCTURA
203 204 331 332 PRIS YD 0.75 ZD 0.75
CONSTANTS
MATERIAL STEEL MEMB 1 3 8 TO 14 16 18 20 21 23 27 TO 30 35 TO 38 43 TO 46 -
51 52 59 TO 61 65 TO 67 71 73 TO 76 81 TO 83 87 TO 90 93 TO 96 115 117 120 -
121 TO 137 139 TO 141 143 147 TO 166 169 TO 181 188 TO 192 194 TO 196 198 -
200 201 207 TO 209 220 TO 223 225 227 232 TO 246 248 250 TO 264 266 -
268 TO 285 312 TO 330 333 TO 342
MATERIAL CONCRETE MEMB 203 204 331 332
SUPPORTS
88 89 157 158 FIXED
1 4 PINNED
DEFINE 1893 LOAD
ZONE 0.36 RF 4 I 1 SS 2 DM 0.05
FLOOR WEIGHT
_G2 FLOAD 7.5
_G2 FLOAD 0.47
_G1 FLOAD 0.53
MEMBER WEIGHT
SELFWEIGHT 1.1
LOAD 1 LOADTYPE Seismic TITLE ELX
1893 LOAD X 1
LOAD 2 LOADTYPE Seismic TITLE ELZ
1893 LOAD Z 1
LOAD 3 LOADTYPE Dead TITLE DL
ONEWAY LOAD
_G1 ONE -1 GY
_G2 ONE -0.47 GY
SELFWEIGHT Y -1.1
MEMBER LOAD
35 36 UNI GY -1.2
FLOOR LOAD
_G2 FLOAD -1.57 GY
LOAD 4 LOADTYPE Live REDUCIBLE TITLE LL
ONEWAY LOAD
_G1 ONE -5 GY
JOINT LOAD
27 TO 30 65 66 73 TO 76 83 84 MX -5.1
7 9 10 12 93 94 99 100 MX -2.55
13 TO 15 97 102 FX 22.37 FZ 1.289

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.std [18-01-2019 09:32] Page 3 of 6


Job Title:

Client:

Engineer:
MEMBER LOAD
35 36 UNI GY -6
LOAD 5 LOADTYPE Wind TITLE WL+X
MEMBER LOAD
9 12 43 TO 46 59 TO 61 65 TO 67 139 140 147 148 161 TO 164 169 TO 174 194 -
195 200 201 220 221 UNI GX 0.489
89 90 121 122 124 125 127 128 312 313 319 320 322 323 325 326 UNI GX 0.489
93 TO 96 314 TO 317 UNI GX 0.489
21 276 333 UNI GX 0.489
18 20 115 117 UNI GX 0.489
8 10 11 13 UNI GX 0.489
LOAD 6 LOADTYPE Wind TITLE WL+Z
MEMBER LOAD
90 122 125 128 313 320 323 326 UNI GZ 0.489
93 314 UNI GZ 0.489
FLOOR LOAD
_FACE-Z FLOAD 1.107 GZ
LOAD 7 LOADTYPE Dead TITLE WATER LOAD
FLOOR LOAD
_G2 FLOAD -13.2 GY
LOAD COMB 8 (1.5DL+1.5(WL+X))
3 1.5 5 1.5
LOAD COMB 9 (1.5DL+1.5(WL-X))
3 1.5 5 -1.5
LOAD COMB 10 (1.5DL+1.5(WL+Z))
3 1.5 6 1.5
LOAD COMB 11 (1.5DL+1.5(WL-Z))
3 1.5 6 -1.5
LOAD COMB 12 (1.2DL+1.2(WL+X)+1.2LL)
3 1.2 5 1.2 4 1.2
LOAD COMB 13 (1.2DL+1.2(WL-X)+1.2LL)
3 1.2 5 -1.2 4 1.2
LOAD COMB 14 (1.2DL+1.2(WL+Z)+1.2LL)
3 1.2 6 1.2 4 1.2
LOAD COMB 15 (1.2DL+1.2(WL-Z)+1.2LL)
3 1.2 6 -1.2 4 1.2
LOAD COMB 16 (1.5DL+1.5(EL+X)+1.5WTL)
3 1.5 1 1.5 7 1.5
LOAD COMB 17 (1.5DL+1.5(EL-X)+1.5WTL)
3 1.5 1 -1.5 7 1.5
LOAD COMB 18 (1.5DL+1.5(EL+Z)+1.5WTL)
3 1.5 2 1.5 7 1.5
LOAD COMB 19 (1.5DL+1.5(EL-Z)+1.5WTL)
3 1.5 2 -1.5 7 1.5
LOAD COMB 20 (1.2DL+1.2(EL+X)+1.2WTL+1.2LL)
3 1.2 1 1.2 7 1.2 4 1.2
LOAD COMB 21 (1.2DL+1.2(EL-X)+1.2WTL+1.2LL)
3 1.2 1 -1.2 7 1.2 4 1.2
LOAD COMB 22 (1.2DL+1.2(EL+Z)+1.2WTL+1.2LL)
3 1.2 2 1.2 7 1.2 4 1.2
LOAD COMB 23 (1.2DL+1.2(EL-Z)+1.2WTL+1.2LL)
3 1.2 2 -1.2 7 1.2 4 1.2
LOAD COMB 24 (1.5DL+1.5(EL+X))
3 1.5 1 1.5

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.std [18-01-2019 09:32] Page 4 of 6


Job Title:

Client:

Engineer:
LOAD COMB 25 (1.5DL+1.5(EL-X))
3 1.5 1 -1.5
LOAD COMB 26 (1.5DL+1.5(EL+Z))
3 1.5 2 1.5
LOAD COMB 27 (1.5DL+1.5(EL-Z))
3 1.5 2 -1.5
LOAD COMB 28 (1.2DL+1.2(EL+X)+1.2LL)
3 1.2 1 1.2 4 1.2
LOAD COMB 29 (1.2DL+1.2(EL-X)+1.2LL)
3 1.2 1 -1.2 4 1.2
LOAD COMB 30 (1.2DL+1.2(EL+Z)+1.2LL)
3 1.2 2 1.2 4 1.2
LOAD COMB 31 (1.2DL+1.2(EL-Z)+1.2LL)
3 1.2 2 -1.2 4 1.2
LOAD COMB 32 (0.9DL+1.5(WL+X))
3 0.9 5 1.5
LOAD COMB 33 (0.9DL+1.5(WL-X))
3 0.9 5 -1.5
LOAD COMB 34 (0.9DL+1.5(WL+Z))
3 0.9 6 1.5
LOAD COMB 35 (0.9DL+1.5(WL-X))
3 0.9 7 -1.5
PERFORM ANALYSIS PRINT ALL
PARAMETER 1
CODE IS800 LSD
FU 450000 MEMB 1 3 8 TO 14 16 18 20 21 23 27 TO 30 35 TO 38 43 TO 46 51 52 -
59 TO 61 65 TO 67 71 73 TO 76 81 TO 83 87 TO 90 93 TO 96 115 117 120 TO 137 -
139 TO 141 143 147 TO 166 169 TO 181 188 TO 192 194 TO 196 198 200 201 207 -
208 TO 209 220 TO 223 225 227 232 234 236 238 241 243 245 250 252 254 256 -
259 261 263 268 TO 285 312 TO 330 333 TO 342
FYLD 310000 MEMB 1 3 8 TO 14 16 18 20 21 23 27 TO 30 35 TO 38 43 TO 46 51 -
52 59 TO 61 65 TO 67 71 73 TO 76 81 TO 83 87 TO 90 93 TO 96 115 117 -
120 TO 137 139 TO 141 143 147 TO 166 169 TO 181 188 TO 192 194 TO 196 198 -
200 201 207 TO 209 220 TO 223 225 227 232 234 236 238 241 243 245 250 252 -
254 256 259 261 263 276 TO 285 312 TO 330 333 TO 342
KY 1.2 MEMB 89 90 93 TO 96 121 122 124 125 127 128 312 TO 317 319 320 322 -
323 325 326
CHECK CODE MEMB 1 3 8 TO 14 16 18 20 21 23 27 TO 30 35 TO 38 43 TO 46 51 52 -
59 TO 61 65 TO 67 71 73 TO 76 81 TO 83 87 TO 90 93 TO 96 115 117 120 TO 137 -
139 TO 141 143 147 TO 166 169 TO 181 188 TO 192 194 TO 196 198 200 201 207 -
208 TO 209 220 TO 223 225 227 232 234 236 238 241 243 245 250 252 254 256 -
259 261 263 268 TO 285 312 TO 330 333 TO 342
PARAMETER 2
CODE IS800 LSD
STEEL MEMBER TAKE OFF LIST 1 3 8 TO 14 16 18 20 21 23 27 TO 30 35 TO 38 43 -
44 TO 46 51 52 59 TO 61 65 TO 67 71 73 TO 76 81 TO 83 87 TO 90 93 TO 96 115 -
117 121 122 124 125 127 128 133 TO 137 139 TO 141 143 147 TO 166 169 TO 181 -
188 TO 192 194 TO 196 198 200 201 207 TO 209 220 TO 223 225 227 232 234 236 -
238 241 243 245 250 252 254 256 259 261 263 276 TO 285 312 TO 317 319 320 -
322 323 325 326 333 TO 342
START CONCRETE DESIGN
CODE INDIAN
FC 25000 MEMB 203 204 331 332
FYMAIN 500000 MEMB 203 331

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.std [18-01-2019 09:32] Page 5 of 6


Job Title:

Client:

Engineer:
FYSEC 500000 MEMB 203 204 331 332
MAXMAIN 32 MEMB 203 204 331 332
MAXSEC 12 MEMB 203 204 331 332
START BAR COMBINATION
MD1 25 MEMB 203 204 331 332
MD2 25 MEMB 203 204 331 332
END BAR COMBINATION
DESIGN COLUMN 203 204 331 332
END CONCRETE DESIGN
PERFORM ANALYSIS PRINT BOTH
FINISH

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.std [18-01-2019 09:32] Page 6 of 6


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 99

|----------------------------------------------------------------------------------|
| Member Number: 1 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.193 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 3 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.233 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 8 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.357 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 9 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.257 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 10 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.181 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 99 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 100

|----------------------------------------------------------------------------------|
| Member Number: 11 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.253 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 12 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.285 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 13 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.192 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 14 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.138 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 16 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.142 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 100 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 101

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 18 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.179 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 20 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.122 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 21 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.299 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 23 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.198 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 101 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 102

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 27 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.188 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 28 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.213 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 29 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.176 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 30 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.161 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 102 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 103

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 35 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.546 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 36 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.517 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 37 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.520 Critical Load Case: 22 Location: 3.08 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 38 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.489 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 7.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 103 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 104

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 43 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.137 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 44 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.207 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 45 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.131 Critical Load Case: 17 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 46 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.082 Critical Load Case: 31 Location: 1.42 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 104 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 105

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 51 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.119 Critical Load Case: 31 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 52 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.169 Critical Load Case: 21 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 59 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.396 Critical Load Case: 18 Location: 0.85 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 60 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.090 Critical Load Case: 35 Location: 3.39 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 105 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 106

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 61 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.100 Critical Load Case: 23 Location: 3.39 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 65 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.394 Critical Load Case: 23 Location: 1.69 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 66 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.109 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 67 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.103 Critical Load Case: 22 Location: 3.39 |
| Critical Condition: Sec. 6.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 106 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 107

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 71 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.114 Critical Load Case: 16 Location: 1.54 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 73 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.198 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 74 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.120 Critical Load Case: 16 Location: 1.54 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 75 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.160 Critical Load Case: 16 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 107 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 108

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 76 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.125 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 81 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.229 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 82 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.141 Critical Load Case: 19 Location: 2.40 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 83 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.060 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 108 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 109

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 87 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.122 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 88 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.162 Critical Load Case: 18 Location: 0.50 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 89 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.209 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 90 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.221 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 109 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 110

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 93 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.198 Critical Load Case: 18 Location: 2.56 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 94 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.208 Critical Load Case: 19 Location: 2.58 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 95 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.201 Critical Load Case: 18 Location: 2.58 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 96 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.213 Critical Load Case: 19 Location: 2.56 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 110 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 111

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 115 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.168 Critical Load Case: 23 Location: 0.88 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 117 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.128 Critical Load Case: 23 Location: 0.88 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 120 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.145 Critical Load Case: 18 Location: 1.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 121 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.111 Critical Load Case: 18 Location: 1.50 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 111 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 112

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 122 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.101 Critical Load Case: 19 Location: 1.50 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 123 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.040 Critical Load Case: 27 Location: 1.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 124 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.109 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 125 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.139 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 112 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 113

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 126 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.041 Critical Load Case: 26 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 127 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.164 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 128 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.145 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 129 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.105 Critical Load Case: 26 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 113 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 114

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 130 |
| Member Section: ST 72X72X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.219 Critical Load Case: 19 Location: 1.80 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 131 |
| Member Section: ST 72X72X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.231 Critical Load Case: 18 Location: 1.80 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 132 |
| Member Section: ST 72X72X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.238 Critical Load Case: 19 Location: 1.80 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 133 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.159 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 114 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 115

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 134 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.157 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 135 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.140 Critical Load Case: 22 Location: 3.08 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 136 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.145 Critical Load Case: 23 Location: 3.08 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 137 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.131 Critical Load Case: 20 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 115 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 116

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 139 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.124 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 140 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.142 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 141 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.144 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 143 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.167 Critical Load Case: 17 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 116 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 117

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 147 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.378 Critical Load Case: 19 Location: 1.13 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 148 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.392 Critical Load Case: 22 Location: 2.82 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 149 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.132 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 150 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.159 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 117 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 118

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 151 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.079 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 152 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.083 Critical Load Case: 19 Location: 3.07 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 153 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.136 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 154 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.134 Critical Load Case: 35 Location: 1.79 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 118 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 119

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 155 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.136 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 156 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.127 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 157 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.436 Critical Load Case: 18 Location: 3.07 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 158 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.457 Critical Load Case: 19 Location: 3.07 |
| Critical Condition: Sec. 7.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 119 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 120

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 159 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.443 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 7.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 160 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.456 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 7.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 161 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.115 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 162 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.166 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 120 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 121

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 163 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.140 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 164 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.073 Critical Load Case: 31 Location: 1.42 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 165 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.118 Critical Load Case: 30 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 166 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.165 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 121 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 122

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 169 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.342 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 170 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.097 Critical Load Case: 35 Location: 3.39 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 171 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.092 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 172 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.321 Critical Load Case: 18 Location: 0.56 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 122 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 123

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 173 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.092 Critical Load Case: 35 Location: 3.39 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 174 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.088 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 175 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.108 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 176 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.161 Critical Load Case: 17 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 123 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 124

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 177 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.121 Critical Load Case: 35 Location: 1.54 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 178 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.159 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 179 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.124 Critical Load Case: 35 Location: 1.28 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 180 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.125 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 124 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 125

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 181 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.102 Critical Load Case: 19 Location: 2.13 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 188 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.125 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 189 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.123 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 190 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.088 Critical Load Case: 18 Location: 3.07 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 125 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 126

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 191 |
| Member Section: ST 200X100X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.090 Critical Load Case: 19 Location: 3.07 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 192 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.122 Critical Load Case: 35 Location: 1.54 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 194 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.125 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 195 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.146 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 126 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 127

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 196 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.129 Critical Load Case: 30 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 198 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.167 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 200 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.344 Critical Load Case: 19 Location: 0.28 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 201 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.337 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 127 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 128

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 207 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.046 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 208 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.053 Critical Load Case: 35 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 209 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.068 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 220 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.221 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 128 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 129

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 221 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.238 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 222 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.187 Critical Load Case: 22 Location: 1.75 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 223 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.171 Critical Load Case: 23 Location: 1.75 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 225 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.171 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 129 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 130

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 227 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.160 Critical Load Case: 17 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 232 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.080 Critical Load Case: 23 Location: 0.18 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 234 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.099 Critical Load Case: 22 Location: 0.23 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 236 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.134 Critical Load Case: 22 Location: 0.23 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 130 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 131

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 238 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.172 Critical Load Case: 20 Location: 0.23 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 241 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.130 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 243 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.095 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 245 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.092 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 8.4 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 131 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 132

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 250 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.076 Critical Load Case: 18 Location: 0.18 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 252 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.077 Critical Load Case: 23 Location: 0.23 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 254 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.118 Critical Load Case: 19 Location: 0.23 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 256 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.163 Critical Load Case: 18 Location: 0.23 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 132 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 133

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 259 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.126 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 261 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.091 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 263 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.079 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 268 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.228 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 133 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 134

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 269 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.195 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 270 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.144 Critical Load Case: 19 Location: 0.59 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 271 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.151 Critical Load Case: 22 Location: 3.54 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 272 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.132 Critical Load Case: 23 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 134 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 135

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 273 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.062 Critical Load Case: 22 Location: 3.54 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 274 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.081 Critical Load Case: 18 Location: 3.54 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 275 |
| Member Section: ST 100X100X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.147 Critical Load Case: 23 Location: 3.54 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 276 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.213 Critical Load Case: 23 Location: 0.17 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 135 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 136

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 277 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.144 Critical Load Case: 19 Location: 0.17 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 278 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.179 Critical Load Case: 23 Location: 0.17 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 279 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.060 Critical Load Case: 16 Location: 0.17 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 280 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.073 Critical Load Case: 19 Location: 0.17 |
| Critical Condition: Sec. 8.4 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 136 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 137

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 281 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.129 Critical Load Case: 19 Location: 0.17 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 282 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.061 Critical Load Case: 19 Location: 0.17 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 283 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.073 Critical Load Case: 19 Location: 0.17 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 284 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.091 Critical Load Case: 22 Location: 0.00 |
| Critical Condition: Sec. 8.4 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 137 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 138

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 285 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.078 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 312 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.215 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 313 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.225 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 314 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.353 Critical Load Case: 22 Location: 2.56 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 138 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 139

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 315 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.194 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 7.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 316 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.190 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 317 |
| Member Section: ST 150X150X6.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.384 Critical Load Case: 19 Location: 2.56 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 318 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.121 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 139 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 140

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 319 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.147 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 320 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.133 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 321 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.038 Critical Load Case: 27 Location: 1.00 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 322 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.146 Critical Load Case: 18 Location: 1.50 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 140 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 141

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 323 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.173 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 324 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.045 Critical Load Case: 19 Location: 0.00 |
| Critical Condition: Sec. 6.2 |

|----------------------------------------------------------------------------------|
| Member Number: 325 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.182 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 326 |
| Member Section: ST 250X250X10.0SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.172 Critical Load Case: 19 Location: 1.50 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 141 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 142

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 327 |
| Member Section: ST 50X50X4.5SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.100 Critical Load Case: 26 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 328 |
| Member Section: ST 72X72X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.227 Critical Load Case: 19 Location: 1.80 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 329 |
| Member Section: ST 72X72X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.258 Critical Load Case: 18 Location: 1.80 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 330 |
| Member Section: ST 72X72X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.254 Critical Load Case: 19 Location: 1.80 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 142 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 143

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 333 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.224 Critical Load Case: 20 Location: 0.87 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 334 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.077 Critical Load Case: 18 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 335 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.196 Critical Load Case: 16 Location: 0.87 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 336 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.160 Critical Load Case: 20 Location: 0.87 |
| Critical Condition: Sec. 9.3.2.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 143 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 144

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 337 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.168 Critical Load Case: 17 Location: 0.87 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 338 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.178 Critical Load Case: 18 Location: 0.87 |
| Critical Condition: Sec. 9.3.2.2 |

|----------------------------------------------------------------------------------|
| Member Number: 339 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.161 Critical Load Case: 19 Location: 0.87 |
| Critical Condition: Sec. 8.2.1.2 |

|----------------------------------------------------------------------------------|
| Member Number: 340 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.168 Critical Load Case: 18 Location: 0.87 |
| Critical Condition: Sec. 8.2.1.2 |

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 144 of 231


Friday, January 18, 2019, 10:38 AM
STAAD SPACE -- PAGE NO. 145

STAAD.PRO CODE CHECKING - IS-800-2007-LSD (V2.0)


****************************************************

|----------------------------------------------------------------------------------|
| Member Number: 341 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.326 Critical Load Case: 22 Location: 0.01 |
| Critical Condition: Sec. 8.4 |

|----------------------------------------------------------------------------------|
| Member Number: 342 |
| Member Section: ST 300X150X6.0RHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.214 Critical Load Case: 19 Location: 0.01 |
| Critical Condition: Sec. 8.4 |

259. PARAMETER 2
260. CODE IS800 LSD
261. STEEL MEMBER TAKE OFF LIST 1 3 8 TO 14 16 18 20 21 23 27 TO 30 35 TO 38 43 -

E:\gaurav\aquaduct\staad model\aqueduct staad bhed-2.anl Page 145 of 231


Annexure B
Page 1 of 10

COMBINED FOUNDATION DESIGN(IS 456-2000)

Result Summary

Left Overhang Right Overhang Length Width Thickness


Footing No.
(m) (m) (m) (m) (m)
1 0.90 0.90 2.80 5.85 0.60

Footing No. Footing Reinforcement


- Main Steel Top Main Steel Bottom Secondary Steel Top Secondary Steel Bottom
1 Ø12 @ 155 mm c/c Ø12 @ 155 mm c/c Ø12 @ 155 mm c/c Ø12 @ 85 mm c/c

Combined Footing 1

Input Data

2 m2 m
1.5 m

0.9 m 0.9 m
0.25 m

0.75 m
0.75 m

2.8 m

1m

Geometry of Footing
For Column 158

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 0.75 m
Column Width - Z (Pw) : 0.75 m

Pedestal

Include Pedestal : Yes


Pedestal Shape : Rectangular
Pedestal Height (Ph) : 2.00 m
Pedestal Length - X (Pl) : 0.75 m
Pedestal Width - Z (Pw) : 0.75 m

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 2 of 10

Eccentricity

Column Offset in Transverse Direction : 0.00 m

For Column 157

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 0.75 m
Column Width - Z (Pw) : 0.75 m

Pedestal

Include Pedestal : Yes


Pedestal Shape : Rectangular
Pedestal Height (Ph) : 2.00 m
Pedestal Length - X (Pl) : 0.75 m
Pedestal Width - Z (Pw) : 0.75 m

Eccentricity

Column Offset in Transverse Direction : 0.00 m

Length of left overhang : 0.60 m


Length of right overhang : 0.60 m
Is the length of left overhang fixed : No
Is the length of right overhang fixed : No
Minimum width of footing (Wo) : 5.50 m
Minimum Thickness of footing (Do) : 600.00 mm
Maximum Width of Footing (Wo) : 40000.00 mm
Maximum Thickness of Footing (Do) : 1500.00 mm
Maximum Length of Footing (Lo) : 40000.00 mm
Length Increment : 50.00 mm
Depth Increment : 50.00 mm

Cover and Soil Properties

Pedestal Clear Cover : 50.00 mm


Footing Clear Cover : 50.00 mm
Unit Weight of soil : 20.00 kN/m3
Soil Bearing Capacity : 100.00 kN/m2
Soil Bearing Capacity Type : Net Bearing
Capacity
Soil Surcharge : 0.00 kN/m2
Depth of Soil above Footing : 1.50 m
Type of Depth : Fixed Top
Depth of Water Table : 10.00 m

Concrete and Rebar Properties

Unit Weight of Concrete : 25.00 kN/m3


Compressive Strength of Concrete : 25.00 N/mm2
Yield Strength of Steel : 500.00 N/mm2
Minimum Bar Size : Ø12
Maximum Bar Size : Ø60
Minimum Pedestal Bar Size : Ø16
Maximum Pedestal Bar Size : Ø60
Minimum Bar Spacing : 50.00 mm
Maximum Bar Spacing : 450.00 mm

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 3 of 10

------------------------------------------------------

Design Calculations

Footing Size Calculations

Gross Soil Bearing Capacity (Un factored) = 142.00 kN/m^2


Reduction of force due to buoyancy = 0.000 kN

Area from initial length and width, Ao = = 15.40 sq m

Min. area required from bearing pressure, Amin = = 10.60 sq m

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final footing dimensions are:

Length of footing, L : 2.80 m


Width of footing, W : 5.85 m
Depth of footing, Do : 0.60 m
Area, A : 16.38 sq m
Length of left overhang, Lleft_overhang : 0.90 m
Length of right overhang, Lright_overhang : 0.90 m

------------------------------------------------------

Load Combinations

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
101 SL:1.000 x DL+1.000 x DL
103 SL:1.000 x DL+1.000 x DL+1.000 x LL
105 SL:1.000 x DL+1.000 x DL+1.000 x WLX+1.000 x WLX
109 SL:1.000 x DL+1.000 x DL+-1.000 x WLX+-1.000 x WLX
113 SL:1.000 x DL+1.000 x DL+1.000 x ELX+1.000 x ELX
117 SL:1.000 x DL+1.000 x DL+-1.000 x ELX+-1.000 x ELX
121 SL:0.800 x DL+0.800 x DL+0.800 x LL+0.800 x WLX+0.800 x WLX
123 SL:0.800 x DL+0.800 x DL+0.800 x LL
125 SL:0.800 x DL+0.800 x DL+0.800 x LL+-0.800 x WLX+-0.800 x WLX
129 SL:0.800 x DL+0.800 x DL+0.800 x LL+0.800 x ELX+0.800 x ELX
133 SL:0.800 x DL+0.800 x DL+0.800 x LL+-0.800 x ELX+-0.800 x ELX

Load Combination/s- Strength Level


Load Combination
Load Combination Title
Number
201 UL:1.500 x DL+1.500 x DL
202 UL:1.500 x DL+1.500 x DL+1.500 x LL
203 UL:0.960 x DL+0.960 x DL+0.960 x LL+0.960 x WLX+0.960 x WLX
204 UL:0.960 x DL+0.960 x DL+0.960 x LL
205 UL:0.960 x DL+0.960 x DL+0.960 x LL+-0.960 x WLX+-0.960 x WLX
207 UL:0.960 x DL+0.960 x DL+0.960 x LL+0.960 x ELX+0.960 x ELX
209 UL:0.960 x DL+0.960 x DL+0.960 x LL+-0.960 x ELX+-0.960 x ELX
211 UL:1.200 x DL+1.200 x DL+1.200 x WLX+1.200 x WLX
212 UL:1.200 x DL+1.200 x DL
213 UL:1.200 x DL+1.200 x DL+-1.200 x WLX+-1.200 x WLX
215 UL:1.200 x DL+1.200 x DL+1.200 x ELX+1.200 x ELX
217 UL:1.200 x DL+1.200 x DL+-1.200 x ELX+-1.200 x ELX
219 UL:0.900 x DL+0.900 x DL+1.200 x WLX+1.200 x WLX
220 UL:0.900 x DL+0.900 x DL
221 UL:0.900 x DL+0.900 x DL+-1.200 x WLX+-1.200 x WLX
223 UL:0.900 x DL+0.900 x DL+1.200 x ELX+1.200 x ELX
225 UL:0.900 x DL+0.900 x DL+-1.200 x ELX+-1.200 x ELX

Applied Loads on Top of Pedestal


Before consideration of self weight and load safety factor table

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 4 of 10

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
-
Column Number : 158
101 426.35 0.22 1.60 6.02 -1.82
103 456.39 0.46 4.26 14.12 -3.47
105 301.58 2.94 12.76 42.14 -12.49
109 551.11 -2.51 -9.56 -30.10 8.86
113 276.08 0.50 15.99 52.67 -3.14
117 576.61 -0.07 -12.78 -40.63 -0.49
121 265.30 2.55 12.33 40.19 -11.32
123 365.11 0.37 3.40 11.30 -2.78
125 464.92 -1.81 -5.52 -17.59 5.76
129 244.90 0.60 14.91 48.62 -3.84
133 485.32 0.14 -8.10 -26.02 -1.72
-
Column Number : 157
101 376.07 0.23 1.57 6.30 -1.94
103 400.84 0.48 3.69 13.08 -3.65
105 501.28 2.86 10.33 36.39 -11.90
109 250.86 -2.40 -7.19 -23.78 8.02
113 526.77 0.41 13.04 45.49 -2.47
117 225.36 0.06 -9.90 -32.89 -1.41
121 420.84 2.49 9.96 34.53 -10.89
123 320.68 0.39 2.95 10.46 -2.92
125 220.51 -1.72 -4.05 -13.61 5.05
129 441.24 0.53 12.13 41.82 -3.34
133 200.11 0.25 -6.22 -20.89 -2.49

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
-
Column Number : 158
201 639.52 0.32 2.40 9.03 -2.73
202 684.59 0.69 6.38 21.19 -5.21
203 318.36 3.06 14.80 48.23 -13.58
204 438.14 0.44 4.09 13.56 -3.33
205 557.91 -2.17 -6.62 -21.11 6.91
207 293.88 0.72 17.90 58.34 -4.61
209 582.39 0.17 -9.72 -31.22 -2.06
211 361.90 3.53 15.31 50.56 -14.99
212 511.62 0.26 1.92 7.22 -2.18
213 661.33 -3.01 -11.47 -36.12 10.63
215 331.30 0.60 19.18 63.20 -3.77
217 691.93 -0.08 -15.34 -48.75 -0.59
219 234.00 3.46 14.83 48.76 -14.45
220 383.71 0.19 1.44 5.42 -1.64
221 533.43 -3.07 -11.95 -37.92 11.17
223 203.40 0.54 18.70 61.39 -3.23
225 564.03 -0.15 -15.82 -50.56 -0.04
-
Column Number : 157
201 564.10 0.35 2.35 9.45 -2.91
202 601.27 0.72 5.54 19.62 -5.47
203 505.01 2.99 11.95 41.44 -13.06
204 384.81 0.46 3.55 12.56 -3.50
205 264.61 -2.06 -4.86 -16.33 6.06
207 529.48 0.63 14.56 50.18 -4.01
209 240.14 0.30 -7.47 -25.07 -2.99
211 601.53 3.43 12.39 43.67 -14.28
212 451.28 0.28 1.88 7.56 -2.33
213 301.03 -2.87 -8.63 -28.54 9.63
215 632.12 0.49 15.65 54.59 -2.96
217 270.44 0.07 -11.89 -39.47 -1.69
219 488.71 3.36 11.92 41.77 -13.70
220 338.46 0.21 1.41 5.67 -1.75
221 188.21 -2.94 -9.10 -30.43 10.21
223 519.30 0.42 15.18 52.70 -2.38
225 157.62 -0.00 -12.36 -41.36 -1.11

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 5 of 10

Pressures at 4 Corners

Pressure at Pressure at
Pressure at top Pressure at top Area of footing in
bottom right bottom left
Load Case left corner right corner uplift (Au)
corner corner
(kN/m^2) (kN/m^2) (sq. m)
(kN/m^2) (kN/m^2)

117 135.5274 54.9068 55.1409 135.7615 0.00

103 100.7377 95.4796 96.6781 101.9363 0.00

103 100.7377 95.4796 96.6781 101.9363 0.00

117 135.5274 54.9068 55.1409 135.7615 0.00

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure
will be set to zero and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at Four Corners

Pressure at top left Pressure at top right Pressure at bottom Pressure at bottom
Load Case corner corner right corner left corner
(kN/m^2) (kN/m^2) (kN/m^2) (kN/m^2)

117 135.5274 54.9068 55.1409 135.7615

103 100.7377 95.4796 96.6781 101.9363

103 100.7377 95.4796 96.6781 101.9363

117 135.5274 54.9068 55.1409 135.7615

------------------------------------------------------

Stability Check

Resisting
Shear X Shear Z
Load Case Sliding Force Ratio X Ratio Z Required FOS
(kN) (kN)
(kN)

101 0.448 3.168 624.805 1394.011 197.198 1.500

103 0.943 7.949 646.734 685.578 81.362 1.500

105 5.800 23.084 624.984 107.759 27.074 1.500

109 4.903 16.747 624.627 127.386 37.297 1.500

113 0.908 29.026 624.982 688.614 21.532 1.500

117 0.011 22.689 624.629 55870.280 27.530 1.500

121 5.036 22.292 578.298 114.833 25.942 1.500

123 0.755 6.359 578.155 766.100 90.918 1.500

125 3.527 9.573 578.013 163.899 60.377 1.500

129 1.122 27.045 578.296 515.332 21.383 1.500

133 0.387 14.327 578.015 1492.945 40.345 1.500

Check for stability against overturning (Moments printed against Local axis)

Resisting Resisting
Moment X Moment Z Required
Load Case Moment X Moment Z Ratio X Ratio Z
(kNm) (kNm) FOS
(kNm) (kNm)

101 4.922 4.580 4568.806 2186.779 928.222 477.463 1.500

103 9.571 20.096 4729.158 2263.529 494.128 112.635 1.500

105 39.474 238.386 4570.110 2187.403 115.776 9.176 1.500

109 29.629 247.546 4567.503 2186.156 154.154 8.831 1.500

113 7.975 298.966 4570.094 2187.396 573.067 7.317 1.500

117 1.869 308.126 4567.518 2186.163 2443.284 7.095 1.500

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 6 of 10

Resisting Resisting
Moment X Moment Z Required
Load Case Moment X Moment Z Ratio X Ratio Z
(kNm) (kNm) FOS
(kNm) (kNm)
121 35.298 210.450 4228.727 2024.006 119.801 9.618 1.500

123 7.657 16.077 4227.684 2023.507 552.165 125.864 1.500

125 19.985 178.296 4226.642 2023.008 211.494 11.346 1.500

129 10.099 258.914 4228.715 2024.000 418.738 7.817 1.500

133 5.214 226.760 4226.654 2023.014 810.571 8.921 1.500

------------------------------------------------------

Design for Flexure

Sagging moment along length

Critical load case : = 202

Effective Depth : = 0.53 m


Governing moment (MuX) : = 148.02 kNm
As Per IS 456 2000 ANNEX G G-1.1C

Limiting Factor1 (Kumax) : = 0.46

Limiting Factor2 (Rumax) : = 3318.15 kN/m^2

Limit Moment Of Resistance (Mumax) : = 5493.72 kNm

Mu <= Mumax hence, safe

Hogging moment along length

Critical load case : = 217

Effective Depth : = 0.53 m

Governing moment (MuX) : = 0.59 kNm


As Per IS 456 2000 ANNEX G G-1.1C

Limiting Factor1 (Kumax) : = 0.46

Limiting Factor2 (Rumax) : = 3318.15 kN/m^2

Limit Moment Of Resistance (Mumax) : = 5493.72 kNm

Mu <= Mumax hence, safe

Transverse direction

Critical load case : = 202


Effective Depth : = 0.53 m

Governing moment (MuZ) : = 793.06 kNm

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 7 of 10

As Per IS 456 2000 ANNEX G G-1.1C

Limiting Factor1 (Kumax) : = 0.46

Limiting Factor2 (Rumax) : = 3318.15 kN/m^2

Limit Moment Of Resistance (Mumax) : = 2629.47 kNm

Mu <= Mumax hence, safe

One-Way Shear

120
90
60
30
0
-30
-60
-90
-120
-150
-180
-210
-240
-270
-300
-330
-360
-390
-420
0 0.5 1 1.5 2 2.5 2.8

Position [m]

0.985 m

0.985 m

Shear Plane Parallel to Foundation Width

Critical load case for maximum shear force along the = 202
length of footing :
Shear Force(S) = 246.62 kN
Shear Stress(Tv) = 79.24 kN/m^2
Percentage Of Steel(Pt) = 0.1381
As Per IS 456 2000 Clause 40 Table 19
Shear Strength Of Concrete(Tc) = 580.00 kN/m^2
Tv< Tc hence, safe

Punching Shear Check

Critical Load case for Punching Shear Check = 217


For Column 1
Shear Force(S) = 591.65 kN
Shear Stress(Tv) = 213.46 kN/m^2
As Per IS 456 2000 Clause 31.6.3.1
Ks = = 1.00

Shear Strength(Tc) = = 1250.00 kN/m^2

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 8 of 10

Ks X Tc = 1250.00 kN/m^2
Tv<= Ks X Tc hence, safe

Critical Load case for Punching Shear Check = 215


For Column 2
Shear Force(S) = 532.59 kN
Shear Stress(Tv) = 192.15 kN/m^2
As Per IS 456 2000 Clause 31.6.3.1
Ks = = 1.00

Shear Strength(Tc) = = 1250.00 kN/m^2

Ks X Tc = 1250.00 kN/m^2
Tv<= Ks X Tc hence, safe

Selection of reinforcement

Top reinforcement along length

As Per IS 456 2000 Clause 26.5.2.1


Minimum Area of Steel (Astmin) = 4212 mm2
Calculated Area of Steel (Ast) = 4212 mm2
Provided Area of Steel (Ast,Provided) = 4298 mm2
Astmin<= Ast,Provided Steel area is accepted

Selected bar Size (db) = Ø12


Minimum spacing allowed (Smin) = 50.00 mm
Selected spacing (S) = 155.08 mm
Smin<= S <= Smax and selected bar size < selected maximum bar size. The reinforcement is
accepted.

Along width

As Per IS 456 2000 Clause 26.5.2.1


Provided Minimum Area of Steel (Astmin) = 2016 mm2

Selected bar Size (db) = Ø12


Minimum spacing allowed (Smin) = 50.00 mm
Selected spacing (S) = 158.12 mm
Smin<= S <= Smax and selected bar size < selected maximum bar size. The reinforcement is
accepted.

Bottom reinforcement along length

As Per IS 456 2000 Clause 26.5.2.1


Minimum Area of Steel (Astmin) = 4212 mm2
Calculated Area of Steel (Ast) = 4212 mm2
Provided Area of Steel (Ast,Provided) = 4298 mm2
Astmin<= Ast,Provided Steel area is
accepted

Selected bar Size (db) = Ø12


Minimum spacing allowed (Smin) = 50.00 mm
Selected spacing (S) = 155.08 mm
Smin<= S <= Smax and selected bar size < selected maximum bar size. The reinforcement is
accepted.

Along width

As Per IS 456 2000 Clause 26.5.2.1


Minimum Area of Steel (Astmin) = 2016 mm2
Calculated Area of Steel (Ast) = 3601 mm2
Provided Area of Steel (Ast,Provided) = 3619 mm2
Astmin<= Ast,Provided Steel area is
accepted

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 9 of 10

Selected bar Size (db) = Ø12


Minimum spacing allowed (Smin) = 50.00 mm
Selected spacing (S) = 86.71 mm
Smin<= S <= Smax and selected bar size < selected maximum bar size. The reinforcement is
accepted.

Provided Reinforcement

Main bar no. for top Reinforcement: Ø12


Spacing of top reinforcement bar : 155.08 mm

Based on spacing reinforcement increment; provided reinforcement is

Ø12 @ 155mm o.c.

Main bar no. for bottom Reinforcement: Ø12


Spacing of bottom reinforcement bar : 155.08 mm

Based on spacing reinforcement increment; provided reinforcement is

Ø12 @ 155mm o.c.

Distribution bar no.: Ø12


Spacing of distribution bars : 86.71 mm

Based on spacing reinforcement increment; provided reinforcement is

Ø12 @ 85mm o.c.

Distribution bar no.(Top): Ø12


Spacing of distribution bars(Top) : 158.12 mm

Based on spacing reinforcement increment; provided reinforcement is

Ø12 @ 155mm o.c.

Pedestal Design

Pedestal Reinforcement Design


For Column 1

Pedestal Dimension

Pedestal Height = 2.00 m

Pedestal Width = 0.75 m

Pedestal Length = 0.75 m

Critcal load Case : 201

Critcal Applied Axial Load: : 640.628 kN

Critcal Applied Moment Along X Direction: : 16.116 kNm

Critcal Applied Moment Along Z Direction: : 16.116 kNm

Pedestal design is performed in accordance with IS 456 Section 39

Position Of Neutral Axis Along X Direction: : 0.165 m

Position Of Neutral Axis Along Z Direction: : 0.165 m

Pedestal Moment Capacity Along X Direction: : 552.254 kNm

Pedestal Moment Capacity Along Z Direction: : 552.254 kNm

Minimum longitudinal pedestal reinforcement is calculated based on

IS-456-2000 Section 26.5.3.1 (Clause 26.5.3.1.a to Clause 26.5.3.1.h)

Provided Main Reinforcemnt: : 2815 mm2

Required Main Reinforcemnt: : 4500 mm2

Pedestal Main/Compression Reinforcement : 24 - Ø16

Pedestal Tie Detail : Ø6 @ 255 mm

For Column 2

Pedestal Dimension

Pedestal Height = 2.00 m

Pedestal Width = 0.75 m

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019
Page 10 of 10

Pedestal Length = 0.75 m

Critcal load Case : 201

Critcal Applied Axial Load: : 565.207 kN

Critcal Applied Moment Along X Direction: : 14.219 kNm

Critcal Applied Moment Along Z Direction: : 14.219 kNm

Pedestal design is performed in accordance with IS 456 Section 39

Position Of Neutral Axis Along X Direction: : 0.158 m

Position Of Neutral Axis Along Z Direction: : 0.158 m

Pedestal Moment Capacity Along X Direction: : 534.012 kNm

Pedestal Moment Capacity Along Z Direction: : 534.012 kNm

Minimum longitudinal pedestal reinforcement is calculated based on

IS-456-2000 Section 26.5.3.1 (Clause 26.5.3.1.a to Clause 26.5.3.1.h)

Provided Main Reinforcemnt: : 2815 mm2

Required Main Reinforcemnt: : 4500 mm2

Pedestal Main/Compression Reinforcement : 24 - Ø16

Pedestal Tie Detail : Ø6 @ 255 mm

------------------------------------------------------
Print Calculation Sheet

file:///E:/gaurav/aquaduct/aquaduct-bhed/combined-2-bhed/Reports/CalculationSheet.... 22-01-2019