Vous êtes sur la page 1sur 2

572745

Pressure sensor 0 – 10 bar (0 – 1,000 kPa), with switching output, analogue output and display

1
4
p
U
2
3

Design
The pressure sensor is fitted on a plastic plate. The plate can be rotated in increments of 15°. The electrical connections are inside a plastic
housing. The electrical connection is made via safety sockets. The unit is mounted on the profile plate using the locking system with the blue
lever (mounting version "A"). The component can be moved in the direction of the slot.

Function
The pressure sensor is a piezo-resistive relative pressure transducer with integrated amplifier and built-in temperature compensation. The
pressure to be measured is transferred to a piezo-resistive element via a silicone layer. The signal change generated in the element is output
as a voltage signal or switching signal at the connector plug via an integrated amplifier.
The pressure sensor has one supply port for compressed air. The measured pressure is shown numerically and graphically on the display. The
pressure is shown in the selected unit (bar, psi, kPa).

24 V

24 V
B 1
4 Q1
p
U
2 Q2
3
0V

Electrical connection of the pressure sensor

© Festo Didactic GmbH & Co. KG 06/2010 1/2


572745
Pressure sensor 0 – 10 bar (0 – 1,000 kPa), with switching output, analogue output and display

Technical data

General

Measured variable Relative pressure

Setting option Teach-in

Swivel range 210°

Subject to change

Pneumatics

Operating pressure 0 – 10 bar (0 – 1,000 kPa)

Operating medium Filtered, unlubricated compressed air, grade of filtration 40 µm

Temperature of medium 0 – +50 °C

Pneumatic connection For plastic tubing with 4 mm O.D.

Subject to change

Electrical

Operating voltage 15 – 30 V DC

Residual ripple Max. 10 %

Analogue output 0 – 10 V

Switching output PNP

Output function N/O or N/C contact, switchable

Switching current Max. 150 mA

Protection class IP 65

Reverse polarity and short circuit protection Integrated

Electrical connection Sockets for cable with 4 mm safety plugs

CE mark In compliance with EU-EMC directive

Subject to change

2/2 © Festo Didactic GmbH & Co. KG 06/2010