Académique Documents
Professionnel Documents
Culture Documents
Home
Profile
About Low Water Pressure
Installation
Our Comprehensive Pump Warranty
Booster Pumps
Single Pump Systems »
Automatic Peripheral Booster Pumps, 0.37kw + 0.55kw
HQ Series , 0.18kw, 0.37kw, 0.75kw ( New! 20% more efficient )
Automatic Jet Priming Booster Pump 0.75kw
Automatic Multi-Stage Booster Pump 1.1kw
Automatic Multistage Booster Pump 2.2kw
Submersible Automatic Multistage Booster Pump
TQ Electronic Booster Pump Series
Hot Water Booster Pump Walrus TQCN Series
Hot Water Booster Pump PW Series
Variable Speed Pumps »
VFF-SERIES - 0.75kw to 3kw ( LX PUMPS )
SPL-V SERIES ( SHIMGE PUMPS )
TPHIC SERIES ( WALRUS PUMPS )
Submersible
Low Suction Submersible Drainage Pump ( 0.4kw , Single Phase )
WQK Series Submersible Sewer Pumps ( 0.75 to 7.5kw, Three Phase )
WQ Series Submersible Sewer Pumps ( 11 & 15kw. Three Phase )
QDX Series Submersible Drainage Pump ( Single Phase)
Submersible Sewage & Dirty Water Pump (1.1KW, 1.5KW, Single Phase)
Submersible Stainless Steel Sewer & Dirty Water Pump, 0.75kw
Multi-stage Submersible Pump
Borehole
Circulating
2 inch High Volume Circulating Pump
Centrifugal Pumps
SHF Series
SGT Series 3 phase
Cpm Series, Single Phase
Other Pump Products
Coolant Pumps
Toilet Macerator Pump
Swimming Pool Pumps
Automatic Pump Controller ( Up to 1.1kw Motors)
Automatic Pump Controller ( Up to 2.2kw Motors)
Contact
Applications:
To work with clean water in domestic applications, irrigation, commercial and light Industrial.
Materials:
http://www.water-booster-pumps.co.za/auto-ms-water-booster-pumps.php 1/5
11/22/2018 Quiet Running Horizontal Multi-Stage Centrifugal Booster Pump
Motor:
MODEL : EEZI-5CM
POWER: 1.1KW , 220 Volt
Max Flow: 120 l/m
Max Rated Flow: 100 l/m
Max Head: 54 m
Max Pressure: 5.4 Bar
PRICE
R4,830.00 VAT Incl.
All Booster Pumps must get there supply from water from a Storage Tank. Booster Pumps cannot simply be
put in line with the municipal feed. Please refer to Schematic Drawing of Pump and Tank.
Piping design
Poor piping design and installation is a common cause of poor centrifugal-pump performance or failure. Poor
piping can result in:
http://www.water-booster-pumps.co.za/auto-ms-water-booster-pumps.php 2/5
11/22/2018 Quiet Running Horizontal Multi-Stage Centrifugal Booster Pump
Cavitation
Performance dropout
Impeller failure
Bearing and mechanical seal failures
Cracked casings
Leaks
Spills
Fires
Suction piping
The EEZI-5M has a 1 inch Inlet. Piping should be at least one nominal pipe size larger than the pump suction
Inlet. Velocities should be less than 2 to 3 ft/sec, and the head loss as a result of friction should be less than 1
ft per 100 ft of equivalent piping length.
Suction lines should be short and free of all unnecessary turns. For flooded suctions, piping should be
continuously sloping downward to the pump suction so that any vapour pockets can migrate back to the
source vessel. For static lifts, the piping should be continuously sloping upward with no air pockets (install
gate valves in horizontal position).
If a gate valve is to be install between Pump and Tank it is recommended the pipe size and gate valve be
increased to 1½ inch and reduced going into the pump back to 1 inch. No non-return valves, strainers or
filters are to be fitted between Pump and Tank.
The pump already has a non-return valve fitted to it and cannot push back on the Tank. Strainers must be
fitted on the pipe work that enters the Tank. Filters can be fitted before entering Tank or on the outlet side of
the pump. Make sure that filters can handle the pressure of the pump.
When making upstream orientation changes, only long-radius elbows should be used. They should not be
connected directly to the pump suction flange, and a minimum of at least two to five pipe diameters of
straight pipe should be between the suction flange and the elbow and between successive elbows.
This reduces swirl and turbulence before the fluid reaches the pump. Otherwise, separation of the leading
edges may occur, with consequent noisy operation and cavitation damage. The outlet pipe may be reduced to
suit the application. Important to remember the smaller the outlet pipe the less volume of water can be
pushed.
The Pump must be covered and protected from the elements. Pumps incorrectly installed are not covered
under the Manufactures Warranty.
Electrical Connection
http://www.water-booster-pumps.co.za/auto-ms-water-booster-pumps.php 3/5
11/22/2018 Quiet Running Horizontal Multi-Stage Centrifugal Booster Pump
Johannesburg
Cnr Malibongwe
Dr & Rietvallei
Rd.
Cosmo City
Unit 3
77 Roma St.
Cosmo Business
Park
Technical Help:
073-161 6249
Wayne
Sales and
Installations:
http://www.water-booster-pumps.co.za/auto-ms-water-booster-pumps.php 4/5
11/22/2018 Quiet Running Horizontal Multi-Stage Centrifugal Booster Pump
KZN
Unit 15
Four Tower
Business Park
5 Valley View Rd
New Germany
Pinetown
KZN
073 161 6249
031 903 4084
Wayne
Email Us!
Pump Warranty
See our Warranty here.
http://www.water-booster-pumps.co.za/auto-ms-water-booster-pumps.php 5/5