Pile lateral capacity based on limiting deflection (5mm):

As per IS 2911 (Part1/Sec 2) :

Pile Diameter D0  1000mm

D04
Pile Moment of inertia π 10 4
Ip  Ip  4.9087  10  mm
64

Pile length above GL LF  0m

Pile Depth of fixity L1  10D0 L1  10 m

Compressive strength of concrete fck  30  MPa

fck kN
Ec  5000   MPa Ec  27386127.9 
Youngs Modulus of pile material MPa 2
m

Limiting Lateral Deflection Ylim  5mm

As per IS 2911 (Part1/Sec 2) clause C.4.2

FS  2.5
Factor of Safety

 
Ylim  12  Ec  Ip
Pile lateral capacity Q  Q  32  kN
L1  LF3  FS