Vous êtes sur la page 1sur 16

HORAS DE MUESTREO 6 HORAS

DENSIDAD DE PULPA
HORA FEED OVER UNDER PRESION
9:00 1320 1240 1950 12.0
G.E
9:30 1330 1250 1960 14.0
10:00 1320 1240 1930 12.0
10:30 1340 1220 1940 12.0
11:00 1330 1230 1920 14.0
11:30 1320 1250 1950 14.0
% solido
12:00 1340 1240 1930 12.0
13:00 1330 1230 1950 12.0
13:30 1340 1250 1930 14.0
14:00 1330 1230 1940 12.0
14:30 1330 1250 1900 12.0
15:00 1320 1240 1950 12.0
16:00 1340 1250 1930 12.0
PROMEDIO 1330 1240 1937 12.6

Densidad 0 0
MALLA MICRON MICRON ALIMENTO OVER FLOW
Peso % Peso Passing Peso % Peso
20 841 850 4.66 0.59 99.41 0.00 0.00
36 500 600 40.22 5.06 94.35 0.15 0.02
45 354 417 55.32 6.96 87.39 0.45 0.07
70 210 356 100.46 12.64 74.75 1.44 0.22
100 149 252 74.79 9.41 65.34 7.56 1.14
140 105 178 69.49 8.74 56.60 28.25 4.27
200 74 126 62.99 7.93 48.67 52.33 7.92
270 53 89 54.09 6.81 41.86 61.62 9.32
325 44 64 18.80 2.37 39.50 28.70 4.34
400 37 41 16.40 2.06 37.44 26.14 3.95
-400 21 297.51 37.44 0.00 454.36 68.74
794.73 100.00 661.00 100.00

EFICIENCIA DE HIDROCICLON
O= 86.51 O = 13.49
F= 48.74 F = 51.26
U= 12.32 U = 87.68
�=𝐧_𝟏 ∗ �_𝟐 ∗
𝟏𝟎𝟎
n1 = 0.87
n2 = 0.87

E= 75.87 Eficiencia

Densidad F/F 1330 Tonelaje Planta


Densidad O/F 1240 Carga a Over
Densidad U/F 1937 Carga a Under
Presión 12.6 Psi

F -200 48.67 % k80 FEED 263.46


O/F -200 86.36 % K80 OVER FLOW 59.18
U/F -200 12.20 % K80 UNDER FLOW 401.81
D-50 74.54 0
74.54 50
ESPECIFICACIONES TECNICAS
Diámetro de Entrada (pulgadas) 5.00
Diámetro de Apex 1.75
Diámetro de Vortex 4.5
presion (psi) 12.6
N° de ciclones operando 4
FEED OVER UNDER
2.82 2.75 2.85

Alimento Tanque a Mina


FEED OVER UNDER
38.45 30.41 74.52

0
VER FLOW UNDER FLOW α ∆i (Error) λ
Passing Peso % Peso Passing (Fi-Ui)(Oi-Ui) (Oi-Ui)²Fi-( α x Oi)-(1- α)Ui ∆i/ φ
100.00 13.48 1.27 98.73 0.9 1.6 0.1 0.03
99.98 104.91 9.86 88.88 60.8 123.3 0.0 -0.02
99.91 144.79 13.61 75.27 298.7 607.1 -0.1 -0.06
99.69 263.62 24.77 50.50 1193.2 2420.1 -0.1 -0.09
98.55 186.21 17.50 33.00 2119.9 4296.6 -0.2 -0.10
94.27 138.54 13.02 19.98 2720.3 5519.5 -0.2 -0.14
86.36 82.81 7.78 12.20 2704.7 5499.4 -0.3 -0.19
77.03 51.50 4.84 7.36 2404.1 4854.6 0.0 -0.02
72.69 11.85 1.11 6.25 2209.5 4415.2 0.3 0.21
68.74 7.81 0.73 5.51 2018.4 3997.5 0.6 0.39
0.00 58.66 5.51 0.00 0.0 0.0 0.0 0.00
1064.18 100.00 15730.5 31734.9

β= α= 0.50
F= 1.00
A relleno hidraulico U= 0.50
A tanque A O= 0.50
CC = 1.02
φ= 1.50

5580 TMSD
50.00 %
50.00 %

µn PRESIÓN
µn Kg/cm² psi Kpa
µn 1.49 21.17 145.89
AJUSTE DE DATOS POR MULTIPLICADORES LAGRANGE
CORRECCIÓN DE DATOS
% Peso Feed % Peso O'Flow
0.62 99.38 -0.02 100.0
5.01 94.37 0.05 100.0
6.92 87.45 0.09 99.9
12.61 74.84 0.23 99.6
9.40 65.44 1.15 98.5
8.70 56.74 4.29 94.2
7.87 48.86 7.94 86.3
6.98 41.89 9.24 77.0
2.60 39.29 4.23 72.8
2.24 37.05 3.87 68.9
37.05 0.00 68.93 0.0
AGRANGE
RECCIÓN DE DATOS
U/O R
% Peso U'Flow
1.25 98.8 1.017 49.57
9.88 88.9 1.017 49.57
13.63 75.2 1.017 49.57
24.79 50.5 1.017 49.57
17.50 32.9 1.017 49.57
13.04 19.9 1.017 49.57
7.81 12.1 1.017 49.57
4.75 7.3 1.017 49.57
1.00 6.4 1.017 49.57
0.64 5.7 1.017 49.57
5.71 0.0 1.017 49.57
50.00

Carga Circulante
ALIMENTO
PARA CALCULO DE EFICIENCIA CALCULADO EFICIENCIA
S
O´FLOW U´FLOW TOTAL % Peso Passing O´FLOW U´FLOW
50.43 -0.87 62.45 61.59 0.62 99.4 -1.4 101.4
50.43 2.42 494.22 496.65 4.97 95.0 0.5 99.5
50.43 4.49 681.39 685.88 6.86 93.1 0.7 99.3
50.43 11.55 1239.28 1250.83 12.51 87.5 0.9 99.1
50.43 57.51 875.22 932.73 9.33 90.7 6.2 93.8
50.43 214.68 651.93 866.61 8.67 91.3 24.8 75.2
50.43 397.12 390.38 787.50 7.87 92.1 50.4 49.6
50.43 461.89 237.68 699.57 7.00 93.0 66.0 34.0
50.43 211.34 49.82 261.17 2.61 97.4 80.9 19.1
50.43 193.32 32.21 225.53 2.26 97.7 85.7 14.3
50.43 3446.55 285.41 3731.96 37.32 62.7 92.4 7.6
50.00 10000.00 100.00

CURVA TROMP
Carga Circulante 100

90

80

70
CURVA TROMP
100

90

80

70

EFICIENCIA - %
60
Column A
50 Column A
40 Column F
30

20

10

0
10 100 1000

TAMAÑO PARTICULA - µm

CURVAS DE G.S. DEL ALIMENTO, OVER FLOW Y UNDER FLOW


100
% PASANTE

80

60

40

20

0
10 100 1
TAMAÑO DE PARTÍCULA (micrones)
Column G Column J Column M
D50 F´D50 O´D50 U´D50 F 80 O/F 80 U/F 80
0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 401.81
0.00 0.00 0.00 0.00 263.46 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00
74.54 48.74 86.51 12.32 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 59.18 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00
74.54 48.74 86.51 12.32 263.46 59.18 401.81
HORAS DE MUESTREO 2:00 HORAS

HORA FEED OVER UNDER PRESION


10:00 1320 1120 1820 10
10:20 1320 1140 1910 16
10:40 1310 1130 1950 18
11:00 1330 1160 1940 16
11:20 1320 1170 1930 16
11:40 1310 1130 1940 16
12:00 1330 1180 1970 18
PROMEDIO 1320 1147 1923 15.7

ANALISIS DE MASAS

MALLA MICRON MICRON ALIMENTO


Peso % Peso Passing
20 841 850 1.98 0.34 99.66
45 354 417 93.99 16.06 83.61
70 210 356 76.68 13.10 70.51
100 149 252 55.11 9.41 61.09
140 105 178 53.48 9.14 51.96
200 74 126 47.37 8.09 43.87
-200 21 256.81 43.87 0.00
585.42 100.00

EFICIENCIA DE HIDROCICLON N1
O 79.13 O 20.87 N2
F 45.57 F 54.43 EFICIENCIA
U 15.48 U 84.52
Densidad F/F
Densidad O/F
PRESIÓN Densidad U/F
Kg/cm² psi Kpa Presión
1.49 21.17 145.89
Tonelaje Planta
Carga a Over
Carga a Under
GRAVEDAD ESPECIFICA

FEED OVER UNDER


2.82 2.75 2.85

PORCENTAJE A SOLIDOS

FEED OVER UNDER


37.56 20.16 73.94

A
OVER FLOW UNDER FLOW α
Peso % Peso Passing Peso % Peso Passing (Fi-Ui)(Oi-Ui) (Oi-Ui)²
0 0.00 100.00 7.12 0.59 99.41 0.15 0.34
12.9 2.89 97.11 271.53 22.36 77.06 131.34 402.23
8.06 1.80 95.31 324.16 26.69 50.37 905.10 2019.74
9.13 2.04 93.27 210.67 17.35 33.02 1691.09 3629.31
35.48 7.94 85.33 166.68 13.72 19.30 2156.41 4359.78
60.11 13.45 71.88 92.47 7.61 11.69 1937.03 3623.16
321.26 71.88 0.00 141.95 11.69 0.00 0.00 0.00
446.94 100.00 1214.58 100.00 6821.12 14034.57

α
0.82 F
0.82 A relleno hidraulico U
67.21 A tanque A O
CC
1320 φ
1147
1923
15.7 Psi k80 FEED 309.25 µn
K80 OVER FLOW 92.06 µn
5580 K80 UNDER FLOW 402.05 µn
49.00
51.00
AJUSTE DE DATOS POR MULTIPLICADORES LAGRANGE
∆i (Error) λ CORRECCIÓN DE DATOS
Fi-(α x Oi)-(1-α)Ui ∆i/φ % Peso Feed % Peso O'Flow % Peso U'Flow
-0.04 -0.02 0.31 99.69 0.01 99.99 0.60 99.40
-3.20 -2.13 13.95 85.74 3.91 96.08 23.44 75.96
-1.70 -1.14 14.10 71.64 1.32 94.76 26.18 49.79
-1.21 -0.81 9.74 61.90 1.88 92.88 17.18 32.61
0.57 0.38 10.32 51.58 7.36 85.51 13.11 19.49
2.93 1.95 9.66 41.92 12.69 72.83 6.81 12.69
0.00 0.00 41.92 0.00 72.83 0.00 12.69 0.00

0.49
1.00
0.51
0.49
1.06
1.50
PARA CALCULO DE EFICIENCIA ALIMENTO CALCULADO
U/O R S
O´FLOW U´FLOW TOTAL % Peso
1.06 48.60 51.40 0.59 30.54 31.13 0.31
1.06 48.60 51.40 191.62 1195.39 1387.01 13.87
1.06 48.60 51.40 64.62 1335.01 1399.63 14.00
1.06 48.60 51.40 92.25 875.97 968.22 9.68
1.06 48.60 51.40 360.79 668.85 1029.64 10.30
1.06 48.60 51.40 621.58 347.08 968.67 9.69
1.06 48.60 51.40 3568.55 647.16 4215.70 42.16
49.00 51.00 10000.00 100.00
ALIMENTO CALCULADO EFICIENCIA
D50 F´D50 O´D50 U´D50 F 80
Passing O´FLOW U´FLOW
99.69 1.88 98.12 0.00 0.00 0.00 0.00 0.00
86.13 13.82 86.18 0.00 0.00 0.00 0.00 309.25
86.00 4.62 95.38 0.00 0.00 0.00 0.00 0.00
90.32 9.53 90.47 0.00 0.00 0.00 0.00 0.00
89.70 35.04 64.96 90.02 45.57 79.13 15.48 0.00
90.31 64.17 35.83 0.00 0.00 0.00 0.00 0.00
57.84 84.65 15.35 0.00 0.00 0.00 0.00 0.00
90.02 45.57 79.13 15.48 309.25
O/F 80 U/F 80

0.00 402.05
0.00 0.00
0.00 0.00
0.00 0.00
92.06 0.00
0.00 0.00
0.00 0.00
92.06 402.05