Vous êtes sur la page 1sur 2

4.

ELECTRICAL PART SPECIFICATIONS & STANDARD


ITEM STANDARD
Model RT62KA/WA/UA/EA/MA, RT58KA/WA/UA/EA/MA
Voltage & Frequency 220V/50~60Hz 230~240V/50Hz 127V/60Hz 110~115V/60Hz 220V/60Hz
Model MK183H-L2U MK183Q-L2U MK172P-L2U MK172C-L2U MK172B-L2U
Starting type RSCR
Compressor
Refrigerant R-134a (160G)
Oil Charge Freol α-10c(Ester), 265cc
Evaporator Freezer Split Fin & Tube Type
Sub-Condenser Forced & Natural Convection Type
Dryer Molecular Sieve XH-9
Capillary tube ID0.76 X L3000
Earth screw BSBN (Brass Screw)

ITEM STANDARD
Type Temperature Selection ON(℃) OFF(℃)
–14℃ –12℃ –16℃
Freezer
Temperature

F-Sensor –20℃ –18℃ –22℃


–25℃ –23℃ –27℃
Type Temperature Selection ON(℃) OFF(℃)
7℃ 8℃ 6℃
Refrigerator
R-Sensor 3℃ 4℃ 2℃
1℃ 2℃ 0℃
First Defrost Cycle
4hr ±10min
(Concurrent Defrost of F and R)
Defrosting
Defrost Cycle Min (8H R), Max (12HR)
Electrical parts

Pause Time 10±2min


Freezer-Sensor
Refrigerator-Sensor THERMISTOR (502AT)
Sensor
FREEZER Evap-Sensor SPEC (5.0KΩ/25℃)
Ambient TEMP-Sensor
Fuse Thermal Fuse for Preventing Over AC250V/10A
(Bimetal) Heating of Freezer Defrost Heater ON(40℃)/OFF(60℃)

6
ITEM STANDARD
SPEC 220V/50~60Hz 240V/50Hz 127V/60Hz 115V/60Hz 220V60Hz
Running-Capacitor 350VAC/5㎌ 350VAC/5㎌ 350VAC/12㎌ 350VAC/12㎌ 350VAC/5㎌
Over-Load Protector 4TM265RFBYY-53
PTC-Relay J531Q34E220M3502
IS3210SNF7A
Motor-Fan 2450/2600
CCW/Φ100
IS3208SCF7A
Motor-Circuit 1650
CCW/Φ120
Fre. 240V/15W
Electrical parts

Lamp
220~240V/25W
Ref.
220~240V/30W
180W/269Ϊ
Heater-Defrost
Glass(L538)

Bimetal-Fuse
ON:40℃/OFF:60℃
Motor-Step NSBA001TB1
Damper DC12V/60
PFN174S-05B
Thermostat
ON: /OFF:
Case-Damper
Thermo ON: /OFF:
Timer-Defrost
8/10
Door Switch AC250/0.7A(SSD-6D)

Vous aimerez peut-être aussi