Vous êtes sur la page 1sur 68

Scott B.

Moore Construction
Property Inspection Report
Cover Page

15242 Jones Rd., White City, OR 97503


Inspection prepared for: Jean Jaeger
Date of Inspection: 4/5/2019 Time: 9am
Age of Home: 49 Size: 1634
Weather: 51 Degrees with light rain.

Inspector: Scott B. Moore


License # CCB 209211 OCHI # 1543
240 Willow Bend Way, Central Point, OR 97502
Phone: 541-621-1793
Email: scottbmooreconstruction@gmail.com
http://www.roguevalleyhomeinspections.com
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Report Summary
Report Summary
The summary below consists of potentially significant findings. These findings can be a safety
hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra
attention to. The summary is not a complete listing of all the findings in the report, and reflects the
opinion of the inspector. Please review all of the pages of the report as the summary alone does not
explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I
recommend obtaining a copy of all receipts, warranties and permits for the work done.
Interior Areas
Page 8 Item: 7 Electrical • Reversed polarity observed in the living plug. Recommend
evaluation by a licensed electrical contractor and review for
costs of repairs as needed before closing.
Page 8 Item: 9 Smoke Detectors • **CARBON MONOXIDE DETECTORS**
• No CO detector present at time of inspection. CO detectors
are required whenever there is a combustible source in the
home or an attached garage. Recommend installation of
adequate detector within 15 feet of each bedroom as per
industry standards before closing.
Page 9 Item: 16 Fireplace • **Wood Fireplaces**
• There is a large hole cut into the firebox and does not
appear to be functional. Recommend complete evaluation of
all firebox and flue conditions by a licensed chimney sweep
before closing.
Page 10 Item: 17 Window Condition • Although functional, most of the windows in the home are
antiquated single pane glass. Consider review for costs of
replacement before occupancy.
Bedrooms
Page 12 Item: 6 Electrical • Open ground observed in this location. Recommend review
for costs of repairs before closing.
Page 12 Item: 8 Floor Condition • In the inspectors opinion the floor is near the end of its useful
life due to typical wear and age. Consider evaluation by a
qualified flooring company and review for costs of
replacement of all carpeted areas in the home before closing.
Page 14 Item: 16 Screen Doors • Sliding door screen is missing. Recommend review for costs
of replacement before closing.
Bathroom

Page 1 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Page 22 Item: 7 GFCI • No GFCI -


Electrical outlets in this bathroom appeared to be in
serviceable condition at the time of the inspection but had no
Ground Fault Circuit Interrupter (GFCI) protection.
Although this condition may have been commonly considered
safe or acceptable at the time the home was originally
constructed, as general knowledge of safe building practices
has improved with the passage of time, building standards
have changed to reflect current understanding.
Consider having GFCI protection installed as a safety
precaution for outlets within 6 feet of a plumbing fixture.
This can be achieved by:
1. Replacing the current standard outlets with GFCI outlets
2. Replacing the outlet in this bathroom circuit which is
nearest the main electrical service panel with a GFCI outlet.
3. Replacing the breaker currently protecting the electrical
circuit which contains these bathroom outlets with a GFCI
breaker.
This condition is typical at other required locations as well.
Recommend evaluation by a licensed electrical contractor and
review for costs of upgrades to current industry standards
before closing.
Page 23 Item: 9 Floor Condition • Carpet is not recommended in bathrooms due to potential to
harbor moisture, which could lead to unwanted mold issues.
Recommend review for costs of replacement before closing.
Page 25 Item: 20 Window Condition • Evidence of condensation observed at this location. This is
an indication of failed seals between the dual glazing of the
window. Recommend evaluation by a qualified window
company and review for costs of replacement before closing.
Bathroom 2
Page 27 Item: 7 GFCI • This GFCI did not respond to the trip device. Recommend
evaluation by a licensed electrical contractor and review for
costs of repairs before closing.
Page 29 Item: 19 Toilets • Although functional, this toilet is loose at the base but there
is no evidence of leaks. Recommend tightening the anchor
bolts before occupancy.
Kitchen
Page 32 Item: 8 Oven & Range • Anti-Tip devises became a UL (Underwriters Laboratories)
safety standard requirement in 1991.
• Anti-tip bracket is missing from range installation. See label
inside oven door. All freestanding, slide-in ranges include an
anti-tip device and is essential in the safe operation of the
range. It provides protection when excess force or weight is
applied to an open oven door. Carried by home building
centers. Recommend installation as per industry standards.
Page 35 Item: 24 GFCI • No GFCI protection present, suggest installing GFCI
protected receptacles for safety.
Laundry
Page 36 Item: 5 Electrical • Missing switch covers observed. Recommend replacement.
Heat/AC
Page 39 Item: 1 Heater Condition • This type of system is beyond the scope of this inspection.
The boiler appeared functional. Consider evaluation by a
qualified technician to verify conditions before closing.
Page 2 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Water Heater
Page 41 Item: 1 Base • There is no pan under either of the heaters. Recommend
installation of adequate drip pans before occupancy.
Page 41 Item: 5 Water Heater • The heater in the laundry room was manufactured in June of
Condition 2000 and is at or near the end of expected service life.
Recommend evaluation by a licensed plumbing contractor
and review for costs of replacement or purchasing a home
warranty before closing.
Page 42 Item: 11 Strapping • Not to code in bathroom 2, requires two steel straps 1/3 from
the top and the bottom. Recommend installation as per
industry standards before closing.
Electrical
Page 44 Item: 1 Electrical Panel • There is a Zinsco service panel present. Zinsco components
are prone to problems that can lead to failures, lack of proper
protection of circuits and other serious issues, including fire
and electrocution. We cannot definitively call this panel
defective, but recommend evaluation by a licensed electrical
contractor to verify conditions and review for costs of
replacement if needed before closing. You can learn more
about this issue at http://www.inspect-
ny.com/electric/zinsco.htm
Page 45 Item: 5 Breakers • Zinsco breakers observed. Consider review for costs of
replacement before closing.
Garage
Page 47 Item: 5 Rafters & Ceiling • The drywall tape is falling from the seams compromising the
integrity of the firewall separation. Recommend evaluation by
a licensed drywall contractor and review for costs of repairs as
needed before closing.,
Page 47 Item: 6 Electrical • Open junction box observed. Recommend evaluation by a
licensed electrical contractor and review for costs of repairs as
needed before closing.
Page 48 Item: 7 GFCI • No GFCI protection present, suggest installing GFCI
protected receptacles for safety.
Page 48 Item: 10 Fire Door • The door between the garage & house is not a fire rated
door. Fire doors are fundamental to the integrity of fire barriers
which provide resistance to the spread of fire, smoke, and
toxic gasses. This means that should a fire occur in the
garage, this door does not afford protection until fire-rescue
people arrive. This door should be replaced with a fire rated
door. Recommend evaluation by a licensed contractor and
review for costs of upgrade to current industry standards
before closing.
Roof
Page 51 Item: 1 Roof Condition • Clean roof areas: Significant amounts of organic debris
evident.
Page 52 Item: 3 Chimney • Minor mortar deterioration at chimney; moss present.
Recommend cleaning and maintenance as needed.
Page 53 Item: 7 Gutter • Clean gutters: Significant amounts of debris evident.
Exterior Areas
Page 57 Item: 2 Window Condition • Most of the components appeared in satisfactory condition
at time of inspection. Recommend review for costs of
replacement of the master bathroom window before closing.
Page 3 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Page 59 Item: 4 Eaves & Facia • Soffits at the home appeared to be in mostly serviceable
condition at the time of the inspection. Areas of mildew like
staining observed. Recommend cleaning as needed before
occupancy.
Page 59 Item: 5 Exterior Paint • Peeling paint observed on many of the exposed wood
surfaces. Recommend evaluation by a licensed painting
contractor and review for costs of repairs as needed before
closing.
Grounds
Page 61 Item: 3 Vegetation • Tree limbs within 10 feet of roof should be trimmed away to
Observations provide air and sunlight to roof, while minimizing debris &
dampness.
Page 62 Item: 5 Patio and Porch • Areas of rot observed in the particle board that wraps the
Deck posts of the porch roof. Recommend evaluation by a licensed
contractor and review for costs of repair/replacement as
needed before closing.
Foundation
Page 65 Item: 7 Access Panel • Limited inspection from the access area only due to
inadequate clearance.
• Recommend at least 18 inches of clear access to gain entry.
Page 66 Item: 9 Sub Flooring • Areas of damaged insulation observed most likely due to
past rodent activity.

Page 4 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire
Inspection Report. Call us after you have reviewed your report, so we can go over any questions
you may have. Remember, when the inspection is completed and the report is delivered, we are still
available to you for any questions you may have, throughout the entire closing process.
Properties being inspected do not "Pass" or "Fail.” - The following report is based on an inspection
of the visible portion of the structure; inspection may be limited by vegetation and possessions.
Depending upon the age of the property, some items like GFI outlets may not be installed; this
report will focus on safety and function, not current code. This report identifies specific non-
code, non-cosmetic concerns that the inspector feels may need further investigation or repair.
For your safety and liability purposes, we recommend that licensed contractors evaluate and repair
any critical concerns and defects. Note that this report is a snapshot in time. We recommend
that you or your representative carry out a final walk-through inspection immediately before
closing to check the condition of the property, using this report as a guide.

Page 5 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Inspection Details
1. Attendance
In Attendance: Seller present • Fully Participated
2. Home Type
Home Type: Single Family Home
3. Occupancy
Occupancy: Occupied - Furnished: Heavy volume of personal and household
items observed. • The utilities were on at the time of inspection. • Access to
some items such as: electrical outlets/receptacles, windows, wall/floor
surfaces, and cabinet interiors may be restricted by furniture or personal
belongings. Any such items are excluded from this inspection report.

Page 6 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Interior Areas
The Interior section covers areas of the house that are not considered part of the Bathrooms,
Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of
hallways, foyer, and other open areas. Within these areas the inspector is performing a visual
inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal
items in the structure may prevent the inspector from viewing all areas on the interior.

The inspector does not usually test for mold or other hazardous materials. A qualified expert should
be consulted if you would like further testing.
1. Bar
Good Fair Poor N/A None

General Condition General Condition

General Condition General Condition


2. Cabinets
Good Fair Poor N/A None

Page 7 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • Operated normally when tested, at time of inspection.

4. Closets
Good Fair Poor N/A None
Observations:
X • No closets were present in this room.

5. Door Bell
Good Fair Poor N/A None

6. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

7. Electrical
Good Fair Poor N/A None
Observations:
X • Some outlets not accessible due to furniture and or stored personal items.
• Reversed polarity observed in the living plug. Recommend evaluation by a
licensed electrical contractor and review for costs of repairs as needed
before closing.
8. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

9. Smoke Detectors
Good Fair Poor N/A None
Observations:
X • **SMOKE DETECTORS**
• Operated when tested.
• **CARBON MONOXIDE DETECTORS**
• No CO detector present at time of inspection. CO detectors are required
whenever there is a combustible source in the home or an attached garage.
Recommend installation of adequate detector within 15 feet of each bedroom
as per industry standards before closing.
10. Stairs & Handrail
Good Fair Poor N/A None
Observations:
X • Appeared functional.

Page 8 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
11. Window-Wall AC or Heat
Good Fair Poor N/A None
Observations:
X X • Functional boiler supplied radiant heater observed.

12. Ceiling Condition


Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
13. Patio Doors
Good Fair Poor N/A None
Observations:
X • There are no patio doors present in this room.

14. Screen Doors


Good Fair Poor N/A None

15. Wall Condition


Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• No concerns in this area.
16. Fireplace
Good Fair Poor N/A None
Materials: Living Room
X Materials: Masonry fireplace noted.
Observations:
• **Wood Fireplaces**
• There is a large hole cut into the firebox and does not appear to be
functional. Recommend complete evaluation of all firebox and flue conditions
by a licensed chimney sweep before closing.

Page 9 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
17. Window Condition
Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Although functional, most of the windows in the home are antiquated single
pane glass. Consider review for costs of replacement before occupancy.

Page 10 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Bedrooms
The main area of inspection in the bedrooms is the structural system. This means that all walls,
ceilings and floors will be inspected. Doors and windows will also be investigated for damage and
normal operation. Personal items in the bedroom may prevent all areas to be inspected as the
inspector will not move personal items.
1. Locations
Locations: Master
2. Cabinets
Good Fair Poor N/A None

General Condition General Condition


3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • None present.

4. Closets
Good Fair Poor N/A None
Observations:
X • The closet is in serviceable condition.

Page 11 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • Some outlets not accessible due to furniture and or stored personal items.
• Open ground observed in this location. Recommend review for costs of
repairs before closing.
7. Fireplace
Good Fair Poor N/A None

8. Floor Condition
Good Fair Poor N/A None
Flooring Types: Carpet is noted.
X Observations:
• In the inspectors opinion the floor is near the end of its useful life due to
typical wear and age. Consider evaluation by a qualified flooring company
and review for costs of replacement of all carpeted areas in the home before
closing.

Page 12 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
9. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

10. Smoke Detectors


Good Fair Poor N/A None
Observations:
X • **Smoke Detectors**
• The smoke detectors operated during the inspection.
11. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.
12. Window-Wall AC or Heat
Good Fair Poor N/A None
Observations:
X • Functional boiler supplied radiant heater observed.

13. Window Condition


Good Fair Poor N/A None

14. Ceiling Condition


Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
15. Patio Doors
Good Fair Poor N/A None
Observations:
X • **Sliding Patio Doors**
• The sliding patio door was functional during the inspection.

Page 13 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

16. Screen Doors


Good Fair Poor N/A None
Observations:
X • Sliding door screen is missing. Recommend review for costs of
replacement before closing.

Page 14 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Bedroom 2
1. Locations
Locations: Hall first right.
2. Cabinets
Good Fair Poor N/A None

General Condition General Condition


3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • None present.

4. Closets
Good Fair Poor N/A None
Observations:
X • The closet is in serviceable condition.

General Condition

Page 15 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • The majority of grounded receptacles , were tested and found to be wired
correctly.
• Some outlets not accessible due to furniture and or stored personal items.
7. Fireplace
Good Fair Poor N/A None

8. Floor Condition
Good Fair Poor N/A None
Flooring Types: Carpet is noted.
X

General Condition
9. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

10. Smoke Detectors


Good Fair Poor N/A None
Observations:
X • **Smoke Detectors**
• The smoke detectors operated during the inspection.
11. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.

Page 16 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

12. Window-Wall AC or Heat


Good Fair Poor N/A None
Observations:
X • Functional boiler supplied radiant heater observed.

13. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection.
14. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
15. Patio Doors
Good Fair Poor N/A None
Observations:
X • There are no patio doors present in this room.

16. Screen Doors


Good Fair Poor N/A None

Page 17 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Bedroom 3
1. Locations
Locations: Hall second right.
2. Cabinets
Good Fair Poor N/A None

General Condition General Condition


3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • None present.

4. Closets
Good Fair Poor N/A None
Observations:
X • The closet is in serviceable condition.

General Condition

Page 18 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • The majority of grounded receptacles , were tested and found to be wired
correctly.
• Some outlets not accessible due to furniture and or stored personal items.
7. Fireplace
Good Fair Poor N/A None

8. Floor Condition
Good Fair Poor N/A None
Flooring Types: Carpet is noted.
X

General Condition
9. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

10. Smoke Detectors


Good Fair Poor N/A None
Observations:
X • **Smoke Detectors**
• The smoke detectors operated during the inspection.
11. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Most areas not accessible due to stored personal items.

Page 19 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

12. Window-Wall AC or Heat


Good Fair Poor N/A None
Observations:
X • Functional boiler supplied radiant heater observed.

13. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection.
14. Ceiling Condition
Good Fair Poor N/A None
Materials: The ceilings are clad in tile squares.
X Observations:
• No concerns in this area.
15. Patio Doors
Good Fair Poor N/A None
Observations:
X • There are no patio doors present in this room.

16. Screen Doors


Good Fair Poor N/A None

Page 20 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Bathroom
Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets.
Because of all the plumbing involved it is an important area of the house to look over. Moisture in the
air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home
inspector will identify as many issues as possible but some problems may be undetectable due to
problems within the walls or under the flooring..
1. Locations
Locations: Master Bathroom
2. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional and in satisfactory condition, at time of inspection.

General Condition
3. Ceiling Condition
Good Fair Poor N/A None
Materials: The ceilings are clad in tile squares.
X Observations:
• No concerns in this area.
4. Counters
Good Fair Poor N/A None
Observations:
X • Plastic laminate tops noted.
• There is normal wear noted for the age of the counter tops.
• No discrepancies noted.

Page 21 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
5. Doors
Good Fair Poor N/A None

6. Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

7. GFCI
Good Fair Poor N/A None
Observations:
X • No GFCI -
Electrical outlets in this bathroom appeared to be in serviceable condition at
the time of the inspection but had no Ground Fault Circuit Interrupter (GFCI)
protection.
Although this condition may have been commonly considered safe or
acceptable at the time the home was originally constructed, as general
knowledge of safe building practices has improved with the passage of time,
building standards have changed to reflect current understanding.
Consider having GFCI protection installed as a safety precaution for outlets
within 6 feet of a plumbing fixture.
This can be achieved by:
1. Replacing the current standard outlets with GFCI outlets
2. Replacing the outlet in this bathroom circuit which is nearest the main
electrical service panel with a GFCI outlet.
3. Replacing the breaker currently protecting the electrical circuit which
contains these bathroom outlets with a GFCI breaker.
This condition is typical at other required locations as well. Recommend
evaluation by a licensed electrical contractor and review for costs of
upgrades to current industry standards before closing.
8. Exhaust Fan
Good Fair Poor N/A None

Page 22 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

9. Floor Condition
Good Fair Poor N/A None
Materials: Carpet is noted.
X Observations:
• Carpet is not recommended in bathrooms due to potential to harbor
moisture, which could lead to unwanted mold issues. Recommend review for
costs of replacement before closing.

General Condition
10. Heating
Good Fair Poor N/A None
Observations:
X • Functional boiler supplied radiant heater observed.

11. Mirrors
Good Fair Poor N/A None
Observations:
X • The mirror is appeared functional and in good visual condition.

12. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

13. Security Bars


Good Fair Poor N/A None

14. Showers
Good Fair Poor N/A None
Observations:
X • **SHOWER BASE**
• No deficiencies observed.
• **SHOWER FAUCET**
• No deficiencies observed.

Page 23 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

15. Shower Walls


Good Fair Poor N/A None
Observations:
X • **MATERIALS**
• Fiberglass surround noted.
• **OBSERVATIONS**
• Appeared functional, minor staining observed.

General Condition
16. Bath Tubs
Good Fair Poor N/A None

17. Enclosure
Good Fair Poor N/A None
Observations:
X • The shower enclosure was functional at the time of the inspection.

18. Sinks
Good Fair Poor N/A None
Observations:
X • **DRAINS**
• No deficiencies observed.
• **SUPPLY**
• No deficiencies observed.

Page 24 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition General Condition


19. Toilets
Good Fair Poor N/A None
Observations:
X • Operated when tested. No deficiencies noted.

20. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Evidence of condensation observed at this location. This is an indication of
failed seals between the dual glazing of the window. Recommend evaluation
by a qualified window company and review for costs of replacement before
closing.

Condensation

Page 25 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Bathroom 2
1. Locations
Locations: Full bath off the hall.
2. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional and in satisfactory condition, at time of inspection.

General Condition
3. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
4. Counters
Good Fair Poor N/A None
Observations:
X • Granite tops noted.
• No discrepancies noted.

General Condition

Page 26 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

7. GFCI
Good Fair Poor N/A None
Observations:
X • This GFCI did not respond to the trip device. Recommend evaluation by a
licensed electrical contractor and review for costs of repairs before closing.
8. Exhaust Fan
Good Fair Poor N/A None

9. Floor Condition
Good Fair Poor N/A None
Materials: Floating laminate type flooring noted.
X Observations:
• No concerns in this area.

General Condition
10. Heating
Good Fair Poor N/A None
Observations:
X • Functional boiler supplied radiant heater observed.

11. Mirrors
Good Fair Poor N/A None
Observations:
X • The mirror is appeared functional and in good visual condition.

12. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

Page 27 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

13. Security Bars


Good Fair Poor N/A None

14. Showers
Good Fair Poor N/A None

15. Shower Walls


Good Fair Poor N/A None

16. Bath Tubs


Good Fair Poor N/A None
Observations:
X • Appeared functional and in good visual condition.

General Condition
17. Enclosure
Good Fair Poor N/A None

18. Sinks
Good Fair Poor N/A None
Observations:
X • **DRAINS**
• No deficiencies observed.
• **SUPPLY**
• No deficiencies observed.

Page 28 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
19. Toilets
Good Fair Poor N/A None
Observations:
X • Although functional, this toilet is loose at the base but there is no evidence
of leaks. Recommend tightening the anchor bolts before occupancy.
20. Window Condition
Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection

Page 29 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Kitchen
The kitchen is used for food preparation and often for entertainment. Kitchens typically include a
stove, dishwasher, sink and other appliances.
1. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional at time of inspection.

General Condition General Condition

General Condition General Condition


2. Counters
Good Fair Poor N/A None
Observations:
X • Granite tops noted.
• There is normal wear noted for the age of the counter tops.
• No discrepancies noted.

Page 30 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
3. Dishwasher
Good Fair Poor N/A None
Observations:
X • Dishwasher was operational at the time of inspection. Dishwashers most
commonly fail internally at the pump, motor or seals. We do not disassemble
these units to inspect these components. We recommend you operate this
unit prior to closing.

General Condition
4. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

5. Garbage Disposal
Good Fair Poor N/A None
Observations:
X • Operated - appeared functional at time of inspection.

6. Microwave
Good Fair Poor N/A None

Page 31 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

7. Cook top condition


Good Fair Poor N/A None
Observations:
X • Electric cook top noted.
• All heating elements operated when tested.

General Condition
8. Oven & Range
Good Fair Poor N/A None
Observations:
X • Oven(s): Electric
• All heating elements operated when tested.
• Anti-Tip devises became a UL (Underwriters Laboratories) safety standard
requirement in 1991.
• Anti-tip bracket is missing from range installation. See label inside oven
door. All freestanding, slide-in ranges include an anti-tip device and is
essential in the safe operation of the range. It provides protection when
excess force or weight is applied to an open oven door. Carried by home
building centers. Recommend installation as per industry standards.

General Condition

Page 32 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

9. Sinks
Good Fair Poor N/A None
Observations:
X • **DRAINS**
• No deficiencies observed.
• **SUPPLY**
• No deficiencies observed.

General Condition General Condition


10. Drinking Fountain
Good Fair Poor N/A None
Observations:
X • There was no drinking fountain present in this kitchen.

11. Spray Wand


Good Fair Poor N/A None
Observations:
X • The spray wand was operated and was functional.

12. Hot Water Dispenser


Good Fair Poor N/A None

13. Soap Dispenser


Good Fair Poor N/A None

14. Trash Compactor


Good Fair Poor N/A None

15. Vent Condition


Good Fair Poor N/A None
Materials: Recirculating
X Observations:
• Exhaust fan is operable.

Page 33 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

16. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection.
17. Floor Condition
Good Fair Poor N/A None
Materials: Floating laminate type flooring noted.
X Observations:
• No concerns in this area.

General Condition
18. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

19. Ceiling Condition


Good Fair Poor N/A None
Materials: The ceilings are clad in wood paneling.
X Observations:
• No concerns in this area.
20. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

21. Patio Doors


Good Fair Poor N/A None
Observations:
X • **Sliding Patio Doors**
• The sliding patio door was functional during the inspection.
22. Screen Doors
Good Fair Poor N/A None

Page 34 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

23. Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

24. GFCI
Good Fair Poor N/A None
Observations:
X • No GFCI protection present, suggest installing GFCI protected receptacles
for safety.
25. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.

Page 35 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Laundry
1. Locations
Locations: Off the kitchen area.
2. Cabinets
Good Fair Poor N/A None

General Condition
3. Counters
Good Fair Poor N/A None

4. Dryer Vent
Good Fair Poor N/A None
Observations:
X • The dryer vent appeared functional.

5. Electrical
Good Fair Poor N/A None
Observations:
X • The dryer plug was tested and is functional.
• Missing switch covers observed. Recommend replacement.

Page 36 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Missing
6. GFCI
Good Fair Poor N/A None

7. Exhaust Fan
Good Fair Poor N/A None
Observations:
X • None present.

8. Gas Valves
Good Fair Poor N/A None
Observations:
X • No gas present.

9. Wash Basin
Good Fair Poor N/A None

10. Floor Condition


Good Fair Poor N/A None
Materials: Floating laminate type flooring noted.
X Observations:
• No concerns in this area.

Page 37 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
11. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

12. Wall Condition


Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
13. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
14. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

15. Doors
Good Fair Poor N/A None

16. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection

Page 38 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Heat/AC
The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the
climate control system for the structure. The goal of these systems is to keep the occupants at a
comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at
a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be
powered by other sources such as butane, oil, propane, solar panels, or wood.

The inspector will usually test the heating and air conditioner using the thermostat or other controls.
For a more thorough investigation of the system please contact a licensed HVAC service person.
1. Heater Condition
Good Fair Poor N/A None
Materials: Location: • The boiler is located in the laundry room
X Materials: Electric boiler radiant heat present, not tested n/a.
Observations:
• This type of system is beyond the scope of this inspection. The boiler
appeared functional. Consider evaluation by a qualified technician to verify
conditions before closing.

General Condition
2. Heater Base
Good Fair Poor N/A None
Observations:
X • The heater base appears to be functional.

3. Enclosure
Good Fair Poor N/A None
Observations:
X • Normal surface rust/corrosion observed, no signs of flaking or excessive
deterioration noted.
4. Venting
Good Fair Poor N/A None

5. Gas Valves
Good Fair Poor N/A None

Page 39 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

6. Refrigerant Lines
Good Fair Poor N/A None

7. AC Compress Condition
Good Fair Poor N/A None

8. Air Supply
Good Fair Poor N/A None

9. Registers
Good Fair Poor N/A None

10. Filters
Good Fair Poor N/A None

11. Thermostats
Good Fair Poor N/A None
Observations:
X • Analog, non-programmable type.
• Functional at the time of inspection.
• Thermostats are not checked for calibration or timed functions.

Page 40 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Water Heater
1. Base
Good Fair Poor N/A None
Observations:
X • There is no pan under either of the heaters. Recommend installation of
adequate drip pans before occupancy.

No Pan No Pan
2. Heater Enclosure
Good Fair Poor N/A None
Observations:
X • The water heater enclosures are functional.

3. Combusion
Good Fair Poor N/A None

4. Venting
Good Fair Poor N/A None

5. Water Heater Condition


Good Fair Poor N/A None
Heater Type: Electric
X Location: One heater is located in the laundry room. • One heater is located
in bathroom 2.
Observations:
• The heater in bathroom 2 was manufactured in August of 2015.
• Tank appears to be in satisfactory condition -- no concerns.
• The heater in the laundry room was manufactured in June of 2000 and is at
or near the end of expected service life. Recommend evaluation by a
licensed plumbing contractor and review for costs of replacement or
purchasing a home warranty before closing.

Page 41 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition General Condition Bathroom 2


6. TPRV
Good Fair Poor N/A None
Observations:
X • Temperature Pressure Release (TPR) valve and discharge pipe --
functional and in satisfactory condition.
7. Number Of Gallons
Good Fair Poor N/A None
Observations:
X • 50 gallons each.

8. Gas Valve
Good Fair Poor N/A None

9. Plumbing
Good Fair Poor N/A None
Materials: Copper
X Observations:
• No deficiencies observed at the visible portions of the supply piping.
10. Overflow Condition
Good Fair Poor N/A None
Materials: Copper • PVC
X Observations:
• Appears to be in satisfactory condition -- no concerns.
11. Strapping
Good Fair Poor N/A None
Observations:
X • The laundry room heater is strapped to current code.
• Not to code in bathroom 2, requires two steel straps 1/3 from the top and
the bottom. Recommend installation as per industry standards before
closing.

Page 42 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Two Required

Page 43 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Electrical
1. Electrical Panel
Good Fair Poor N/A None
Location: Main Location: • Panel box located in the laundry room.
X Observations:
• There is a Zinsco service panel present. Zinsco components are prone to
problems that can lead to failures, lack of proper protection of circuits and
other serious issues, including fire and electrocution. We cannot definitively
call this panel defective, but recommend evaluation by a licensed electrical
contractor to verify conditions and review for costs of replacement if needed
before closing. You can learn more about this issue at http://www.inspect-
ny.com/electric/zinsco.htm

General Condition General Condition

Zinsco
2. Main Amp Breaker
Good Fair Poor N/A None
Observations:
X • 200 amp

Page 44 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

3. Breakers in off position


Good Fair Poor N/A None

4. Cable Feeds
Good Fair Poor N/A None
Observations:
X • There is an overhead service drop noted.

5. Breakers
Good Fair Poor N/A None
Materials: Copper non-metallic sheathed cable noted.
X Observations:
• Zinsco breakers observed. Consider review for costs of replacement before
closing.
6. Fuses
Good Fair Poor N/A None

Page 45 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Garage
1. Roof Condition
Good Fair Poor N/A None
Materials: Roofing is the same as main structure.
X Materials: Composition shingles noted.
Observations:
• No major system safety or function concerns noted at time of inspection.
2. Walls
Good Fair Poor N/A None
Observations:
X • Appeared satisfactory, at time of inspection.
• Personal items in garage block complete inspection of all floor, wall and
ceiling areas.

General Condition General Condition


3. Anchor Bolts
Good Fair Poor N/A None
Observations:
X • The anchor bolts were not visible.

4. Floor Condition
Good Fair Poor N/A None
Materials: Bare concrete floors noted.
X Observations:
• Common cracks noted.

Page 46 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
5. Rafters & Ceiling
Good Fair Poor N/A None
Observations:
X • Dimensional lumber wood ceiling joists.
• Rafter construction noted.
• No deficiencies observed at the visible portions of the roof framing.
• The drywall tape is falling from the seams compromising the integrity of the
firewall separation. Recommend evaluation by a licensed drywall contractor
and review for costs of repairs as needed before closing.,

Falling
6. Electrical
Good Fair Poor N/A None
Observations:
X • Most of the outlets not accessible due to furniture and or stored personal
items.
• Open junction box observed. Recommend evaluation by a licensed
electrical contractor and review for costs of repairs as needed before closing.

Page 47 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Open
7. GFCI
Good Fair Poor N/A None
Observations:
X • No GFCI protection present, suggest installing GFCI protected receptacles
for safety.
8. 240 Volt
Good Fair Poor N/A None
Observations:
X • There are no 240 volt outlets visible in this room.

9. Exterior Door
Good Fair Poor N/A None
Observations:
X • Appeared functional, at time of inspection.

10. Fire Door


Good Fair Poor N/A None
Observations:
X • The door between the garage & house is not a fire rated door. Fire doors
are fundamental to the integrity of fire barriers which provide resistance to
the spread of fire, smoke, and toxic gasses. This means that should a fire
occur in the garage, this door does not afford protection until fire-rescue
people arrive. This door should be replaced with a fire rated door.
Recommend evaluation by a licensed contractor and review for costs of
upgrade to current industry standards before closing.

Page 48 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Not Rated
11. Garage Door Condition
Good Fair Poor N/A None
Materials: Two 8' x 7' sectional roll up doors observed.
X Observations:
• No deficiencies observed.

General Condition General Condition


12. Garage Door Parts
Good Fair Poor N/A None
Observations:
X • The garage doors appeared functional during the inspection.

13. Garage Opener Status


Good Fair Poor N/A None
Observations:
X • Chain drive opener noted.
• Appeared functional using normal controls, at time of inspection.
• Only one door has an opener.
14. Garage Door's Reverse Status
Good Fair Poor N/A None
Observations:
X • Eye beam system present and operating.

Page 49 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

15. Ventilation
Good Fair Poor N/A None

16. Vent Screens


Good Fair Poor N/A None

17. Cabinets
Good Fair Poor N/A None

18. Counters
Good Fair Poor N/A None

19. Wash Basin


Good Fair Poor N/A None

Page 50 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Roof
1. Roof Condition
Good Fair Poor N/A None
Materials: Roof was visually inspected from accessible points on the interior
X and/or exterior. If a roof is too high, is too steep, is wet, or is composed of
materials which can be damaged if walked upon, the roof is not mounted or
some areas not walked upon. Therefore, client is advised that this is a limited
review and a licensed roofer should be contacted if a more detailed report is
desired.
Materials: Composition shingles noted.
Observations:
• Limited wear and loss of granules observed throughout the roof. Common
condition for the age of the shingles. With normal maintenance we would
estimate 20+ years of service life remaining in these shingles.
• Clean roof areas: Significant amounts of organic debris evident.

General Condition General Condition

General Condition Typical

Page 51 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Debris
2. Flashing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional.

General Condition
3. Chimney
Good Fair Poor N/A None
Observations:
X • Minor mortar deterioration at chimney; moss present. Recommend cleaning
and maintenance as needed.

Page 52 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
4. Sky Lights
Good Fair Poor N/A None

5. Spark Arrestor
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional.

6. Vent Caps
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional.

General Condition General Condition


7. Gutter
Good Fair Poor N/A None
Observations:
X • Clean gutters: Significant amounts of debris evident.

Page 53 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Attic
1. Access
Good Fair Poor N/A None
Observations:
X • **Location of access**
• Scuttle hole located in the hall ceiling.
• **Access Observations**
• Entering attics that are heavily insulated can cause damage to the
insulation and attic framing. Attics with deep insulation cannot be safely
inspected due to limited visibility of the framing members upon which the
inspector must walk. In such cases,the attic is only partially accessed,
thereby limiting the review of the attic area from the hatch area only.

Typical
2. Structure
Good Fair Poor N/A None
Observations:
X • No deficiencies observed in the visible portions of the roof structure.

Typical Typical

Page 54 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Typical Typical
3. Ventilation
Good Fair Poor N/A None
Observations:
X • Gable louver vents noted.
• Fixed, roof-field exhaust vent noted.
4. Vent Screens
Good Fair Poor N/A None
Observations:
X • Vent screens noted as functional.

5. Duct Work
Good Fair Poor N/A None
Observations:
X • None observed.

6. Electrical
Good Fair Poor N/A None
Observations:
X • All areas not accessible due to insulation.

7. Attic Plumbing
Good Fair Poor N/A None
Observations:
X • No deficiencies noted in plumbing vent piping.

8. Insulation Condition
Good Fair Poor N/A None
Materials: Unfinished fiberglass batts noted. • Blown in cellulose insulation
X noted.
Depth: Insulation averages about 10-12 inches in depth
Observations:
• Insulation appears adequate. Roughly an R-30 value observed.
9. Chimney
Good Fair Poor N/A None
Observations:
X • Masonry intact where visible.

Page 55 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

10. Exhaust Vent


Good Fair Poor N/A None
Observations:
X • Could not access.

Page 56 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Exterior Areas
1. Doors
Good Fair Poor N/A None
Observations:
X • Appeared in functional condition at time of inspection.

Typical Typical

Typical
2. Window Condition
Good Fair Poor N/A None
Observations:
X • Most of the components appeared in satisfactory condition at time of
inspection. Recommend review for costs of replacement of the master
bathroom window before closing.

Page 57 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Typical Typical

Typical
3. Siding Condition
Good Fair Poor N/A None
Materials: Vinyl siding, wood frame construction, concrete / block foundation
X Observations:
• No major system safety or function concerns noted at time of inspection.

Page 58 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Vinyl
4. Eaves & Facia
Good Fair Poor N/A None
Observations:
X • Soffits at the home appeared to be in mostly serviceable condition at the
time of the inspection. Areas of mildew like staining observed. Recommend
cleaning as needed before occupancy.

Typical Stains
5. Exterior Paint
Good Fair Poor N/A None
Observations:
X • Peeling paint observed on many of the exposed wood surfaces.
Recommend evaluation by a licensed painting contractor and review for
costs of repairs as needed before closing.

Page 59 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Typical Typical
6. Stucco
Good Fair Poor N/A None

Page 60 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Grounds
1. Driveway and Walkway Condition
Good Fair Poor N/A None
Materials: Gravel driveway noted.
X Observations:
• Driveway in good shape for age and wear. No deficiencies noted.

General Condition
2. Grading
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

3. Vegetation Observations
Good Fair Poor N/A None
Observations:
X • Tree limbs within 10 feet of roof should be trimmed away to provide air and
sunlight to roof, while minimizing debris & dampness.

Trim

Page 61 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

4. Gate Condition
Good Fair Poor N/A None
Materials: Wrought iron • Chain link
X Observations:
• The gates are functional.
5. Patio and Porch Deck
Good Fair Poor N/A None
Observations:
X • Appears in satisfactory and functional condition with normal wear for its
age.
• Areas of rot observed in the particle board that wraps the posts of the porch
roof. Recommend evaluation by a licensed contractor and review for costs of
repair/replacement as needed before closing.

General Condition General Condition

General Condition Rot


6. Stairs & Handrail
Good Fair Poor N/A None

Page 62 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

7. Grounds Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

8. GFCI
Good Fair Poor N/A None
Observations:
X • GFCI receptacles are in good condition.

9. Main Gas Valve Condition


Good Fair Poor N/A None

10. Plumbing
Good Fair Poor N/A None
Materials: Copper piping noted.
X Observations:
• Appeared adequate and functional.
11. Water Pressure
Good Fair Poor N/A None

12. Pressure Regulator


Good Fair Poor N/A None

13. Exterior Faucet Condition


Good Fair Poor N/A None
Location: Various locations.
X Observations:
• Appeared adequate and functional.
14. Balcony
Good Fair Poor N/A None

15. Patio Enclosure


Good Fair Poor N/A None

16. Patio and Porch Condition


Good Fair Poor N/A None
Materials: Rolled roofing noted.
X Observations:
• No major system safety or function concerns noted at time of inspection.

Page 63 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

General Condition
17. Fence Condition
Good Fair Poor N/A None
Materials: Steel and wire.
X Observations:
• Appeared serviceable at time of inspection. Structural assembly
inaccessible.
18. Sprinklers
Good Fair Poor N/A None

Page 64 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

Foundation
1. Slab Foundation
Good Fair Poor N/A None

2. Foundation Perimeter
Good Fair Poor N/A None
Observations:
X • No deficiencies were observed at the visible portions of the structural
components of the home.
3. Foundation Walls
Good Fair Poor N/A None
Observations:
X • Normal settlement.
• Visible portions of foundation wall were dry at the time of the inspection.
See Limitations.
4. Cripple Walls
Good Fair Poor N/A None
Observations:
X • Concrete block/wood piers support floor above.

5. Ventilation
Good Fair Poor N/A None
Observations:
X • Screened openings noted.

6. Vent Screens
Good Fair Poor N/A None
Observations:
X • Vent screens noted as functional.

7. Access Panel
Good Fair Poor N/A None
Observations:
X • Limited inspection from the access area only due to inadequate clearance.
• Recommend at least 18 inches of clear access to gain entry.

Location Recommend 18 inches

Page 65 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

8. Post and Girders


Good Fair Poor N/A None
Observations:
X • Beam Material: Wood
• Concrete block/wood piers support floor above.
• No deficiencies were observed at the visible portions of the structural
components of the home. See Limitations.
9. Sub Flooring
Good Fair Poor N/A None
Observations:
X • **DECKING**
• Plywood sheathing sub floor.
• **FRAMING**
• Dimensional lumber wood Joists
• Visible areas appear satisfactory at the time of inspection. See limitations.
• Areas of damaged insulation observed most likely due to past rodent
activity.

Typical Fallen
10. Anchor Bolts
Good Fair Poor N/A None
Observations:
X • The anchor bolts were not visible.

11. Foundation Electrical


Good Fair Poor N/A None
Observations:
X • Could not access for evaluation.

12. Foundation Plumbing


Good Fair Poor N/A None
Observations:
X • **SUPPLY**
• 1 inch Copper
• **DRAIN, WASTE, VENT**
• Acrylonitrile-Butadiene-Stryrene "ABS" waste and vent pipes noted.
• **OBSERVATIONS**
• Appears Functional at time of inspection.
• Moat not accessible.

Page 66 of 67
Scott B. Moore Construction 15242 Jones Rd., White City, OR

ABS Copper
13. Sump Pump
Good Fair Poor N/A None

14. Ducting
Good Fair Poor N/A None

Page 67 of 67