Vous êtes sur la page 1sur 31
GEOTECHNICAL INVESTIGATIONS FOR THE CONSTRUCTION OF 0.5 DORMITORY FOR BOYS AND 0.5 DORMITORY FOR GIRLS (EACH OF 4 STOREY) AT JNV PANDOH, MANDI (H.P.). a CONTENT - SRNO. CHAPTER PAGE NO. m 3. Dynamic Cone Fanetration Test (OCPT) 2 i ‘ Meola tits Testing 3 rs 6 Foundation Parameters 7 ~ 8. ‘Computation of Allowable Bearing Capacity Values 8 . 8. Recommendations: 15 GEOTECHNICAL INVESTIGATIONS FOR THE CONSTRUCTION OF 0.5 DORMITORY FOR BOYS AND 0.§ DORMITORY FOR GIRLS (EACH OF 4 STOREY) AT JNV PANDOH, MANDI (HP). INTRODUCTION 414 General ‘The work was cartied out af the behest of the Assistant Engineer, Babel Central ‘Sub Division, CPWYD, ITSP Campus, Babel, Kullu (H.) 4.2 Object ‘The object was to obtain sequence and extent of sub-eoil and to ascertain the characteristics of sub-soil so as to anive at design parameters for the foundations of proposed structures. 13 Test Point Locations Investigations were cartied out at eight locations with details as under, site Covered by Boys Dormitory Leet to Loeg GisDormtary ——Leo-StoLoc-8 ‘Test point locations are shown in figures 4.1 and 4.2. 44 Sub-soil Water Conditions Sub-soll water fevel was not met upto the explored depth at the proposed site, Field investigations were carried out in the month of July, 2071 15 Notations The various notations of soll paramotors as recommended by BIS are given in Appendix-t

Vous aimerez peut-être aussi