Académique Documents
Professionnel Documents
Culture Documents
, Ltd
Instrument List
(*) Determined at detail engineering
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1 EV-A1101 DGA-11121-01 1100A RCL Line to OSBL EV Automatic Valve RCL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
2 EV-A1102 DGA-11121-01 1100A MX-A1101/1,2 CL Feed EV Automatic Valve CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
3 EV-A1103 DGA-11121-01 1100A CL Line N3 Feed EV Automatic Valve N3 Gas 37.05 Nm3/h 28.5 Nm3/h 8.55 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
4 EV-A1104 DGA-11121-01 1100A RG Line MT Feed EV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
HF-A1101/1,2,3,4,5,6,7 MT Feed
5 EV-A1105 DGA-11121-01 1100A Automatic Valve MT Gas 140.4 Nm3/h 108.0 Nm3/h 32.4 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
EV
6 FG-A1102 DGA-11121-01 1100A CL Line N3 Feed Flow Area Flowmeter N3 Gas 37.05 Nm3/h 28.5 Nm3/h 8.55 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
7 FI-A1101 DGA-11121-01 1100A MX-A1101/1,2 CL Feed Flow Flowmeter CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
8 FI-A1103 DGA-11121-01 1100A RCL Line to OSBL Flow Flowmeter RCL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
9 FI-A1104 DGA-11121-01 1100A MX-A1101/1 CL Feed Flow Flowmeter CL Gas 1262.235 Nm3/h 971.0 Nm3/h 291.285 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
10 FI-A1105 DGA-11121-01 1100A MX-A1101/2 CL Feed Flow Flowmeter CL Gas 1262.235 Nm3/h 971.0 Nm3/h 291.285 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
11 FI-A1109 DGA-11121-01 1100A MX-A1101/1,2 RG Feed Flow Flowmeter RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
12 FI-A1110 DGA-11121-01 1100A MX-A1101/1 RG Feed Flow Flowmeter RG Gas 5166.785 Nm3/h 3974.5 Nm3/h 1192.335 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
13 FI-A1111 DGA-11121-01 1100A MX-A1101/2 RG Feed Flow Flowmeter RG Gas 5166.785 Nm3/h 3974.5 Nm3/h 1192.335 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
14 FI-A1112 DGA-11121-01 1100A RE-A1101/1 RG Feed Flow Flowmeter RG Gas 1836.9 Nm3/h 1413.0 Nm3/h 423.9 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
15 FI-A1114 DGA-11121-01 1100A RE-A1101/2 RG Feed Flow Flowmeter RG Gas 1836.9 Nm3/h 1413.0 Nm3/h 423.9 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
16 FI-A1116 DGA-11121-01 1100A RE-A1101/3 RG Feed Flow Flowmeter RG Gas 1836.9 Nm3/h 1413.0 Nm3/h 423.9 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
17 FI-A1118 DGA-11121-01 1100A RE-A1101/4 RG Feed Flow Flowmeter RG Gas 1836.9 Nm3/h 1413.0 Nm3/h 423.9 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
18 FI-A1120 DGA-11121-01 1100A RE-A1101/5 RG Feed Flow Flowmeter RG Gas 1836.9 Nm3/h 1413.0 Nm3/h 423.9 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
19 FI-A1122 DGA-11121-01 1100A RE-A1101/6 RG Feed Flow Flowmeter RG Gas 1836.9 Nm3/h 1413.0 Nm3/h 423.9 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
20 FI-A1124 DGA-11121-01 1100A RE-A1101/7 RG Feed Flow Flowmeter RG Gas 1836.9 Nm3/h 1413.0 Nm3/h 423.9 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
1 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
21 FIC-A1102 DGA-11121-01 1100A MX-A1101/1,2 CL Feed Flow Flowmeter CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
23 FIC-A1106 DGA-11121-01 1100A RG Line MT Feed Flow Flowmeter MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
27 FIC-A1108 DGA-11121-01 1100A MX-A1101/1,2 RG Feed Flow Flowmeter RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
29 FIC-A1113 DGA-11121-01 1100A HF-A1101/1 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
31 FIC-A1115 DGA-11121-01 1100A HF-A1101/2 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
33 FIC-A1117 DGA-11121-01 1100A HF-A1101/3 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
35 FIC-A1119 DGA-11121-01 1100A HF-A1101/4 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
37 FIC-A1121 DGA-11121-01 1100A HF-A1101/5 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
39 FIC-A1123 DGA-11121-01 1100A HF-A1101/6 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
41 FIC-A1125 DGA-11121-01 1100A HF-A1101/7 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
44 PG-A1101 DGA-11121-01 1100A MX-A1101/1,2 CL Feed Press. Pressure gauge CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
45 PG-A1102 DGA-11121-01 1100A MX-A1101/1,2 CL Feed Press. Pressure gauge CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
46 PG-A1103 DGA-11121-01 1100A RG Line MT Feed Press. Pressure gauge MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
47 PG-A1104 DGA-11121-01 1100A MX-A1101/1,2 RG Feed Press. Pressure gauge RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
HF-A1101/1,2,3,4,5,6,7 MT Feed
48 PG-A1105 DGA-11121-01 1100A Pressure gauge MT Gas 140.4 Nm3/h 108.0 Nm3/h 32.4 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
Press.
49 PI-A1102 DGA-11121-01 1100A RG Line MT Feed Press. Pressure transmitter MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
50 PI-A1103 DGA-11121-01 1100A MX-A1101/1,2 RG Feed Press. Pressure transmitter RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
51 PI-A1104 DGA-11121-01 1100A MX-A1101/1,2 RG Outlet Press. Pressure transmitter RG Gas 12858.04 Nm3/h 9890.8 Nm3/h 2967.24 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
52 PIC-1101 DGA-11121-01 1100A CL Main Line Press. Pressure transmitter CL Gas 5139.94 Nm3/h 3953.8 Nm3/h 1186.14 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
53 PIC-1101V DGA-11121-01 1100A CL Main Line Control Valve Control Valve CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 0.25 kg/cm2 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
MX-A1101/1,2 RG O2
54 QI-A1101 DGA-11121-01 1100A GAS detector(O2) RG Gas 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
Concentration
91 XA-A1101 DGA-11121-01 1100A HF-A1101/1 Flame Detector Flame Detector AIR Gas - - - ATM ATM
2 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
92 XA-A1102 DGA-11121-01 1100A HF-A1101/2 Flame Detector Flame Detector AIR Gas - - - ATM ATM
93 XA-A1103 DGA-11121-01 1100A HF-A1101/3 Flame Detector Flame Detector AIR Gas - - - ATM ATM
94 XA-A1104 DGA-11121-01 1100A HF-A1101/4 Flame Detector Flame Detector AIR Gas - - - ATM ATM
95 XA-A1105 DGA-11121-01 1100A HF-A1101/5 Flame Detector Flame Detector AIR Gas - - - ATM ATM
96 XA-A1106 DGA-11121-01 1100A HF-A1101/6 Flame Detector Flame Detector AIR Gas - - - ATM ATM
97 XA-A1107 DGA-11121-01 1100A HF-A1101/7 Flame Detector Flame Detector AIR Gas - - - ATM ATM
98 FI-A1126 DGA-11121-02 1100A HE-A1101/1 SC Feed Flow Flowmeter SC Liquid 1716 kg/h 1320.0 kg/h 396 kg/h 8.00 kgf/cm2G 6.10 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
99 FI-A1127 DGA-11121-02 1100A HE-A1101/2 SC Feed Flow Flowmeter SC Liquid 1716 kg/h 1320.0 kg/h 396 kg/h 8.00 kgf/cm2G 6.10 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
100 FI-A1128 DGA-11121-02 1100A HE-A1101/3 SC Feed Flow Flowmeter SC Liquid 1716 kg/h 1320.0 kg/h 396 kg/h 8.00 kgf/cm2G 6.10 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
101 LG-A1101 DGA-11121-02 1100A HE-A1101/1 Level Level gauge SC Liquid - - - 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 134.0 deg C 931.1 kg/m3 0.21 cP
102 LG-A1102 DGA-11121-02 1100A HE-A1101/2 Level Level gauge SC Liquid - - - 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 134.0 deg C 931.1 kg/m3 0.268 cP
103 LG-A1103 DGA-11121-02 1100A HE-A1101/3 Level Level gauge SC Liquid - - - 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 134.0 deg C 931.1 kg/m3 0.268 cP
110 PG-A1106 DGA-11121-02 1100A FL-A1101/1,2 S2 Outlet Press. Pressure gauge S2 Vapor 3432 kg/h 2640.0 kg/h 792 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
111 PI-A1105 DGA-11121-02 1100A HE-A1101/1,2 RG Feed Press. Pressure transmitter RG Gas 12857.65 Nm3/h 9890.5 Nm3/h 2967.15 Nm3/h 2.00 kgf/cm2G 0.70 kgf/cm2G 500.0 deg C 420.0 deg C 2.1 kg/Nm3 0.268 cP
HE-A1102/1,2,3,4,5 RG Feed
112 PI-A1106 DGA-11121-02 1100A Pressure transmitter RG Gas 12857.65 Nm3/h 9890.5 Nm3/h 2967.15 Nm3/h 2.00 kgf/cm2G 0.65 kgf/cm2G 180.0 deg C 160.0 deg C 2.1 kg/Nm3 0.018 cP
Press.
113 PI-A1107 DGA-11121-02 1100A HE-A1103/1 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
3 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
114 PI-A1108 DGA-11121-02 1100A HE-A1103/2 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
115 PI-A1109 DGA-11121-02 1100A HE-A1103/3 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
116 PI-A1110 DGA-11121-02 1100A HE-A1103/4 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
117 PI-A1111 DGA-11121-02 1100A HE-A1103/5 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
HE-A1103/1,2,3,4,5 RG Outlet
118 PI-A1112 DGA-11121-02 1100A Pressure transmitter RG Gas 12857.65 Nm3/h 9890.5 Nm3/h 2967.15 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
Press.
119 SV-A1101 DGA-11121-02 1100A RG Line RCL Outlet SV Automatic Valve RCL Gas 2.00 kgf/cm2G 0.55 kgf/cm2G - 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
135 EV-B1101 DGA-11122-01 1100B RCL Line to OSBL EV Automatic Valve RCL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
136 EV-B1102 DGA-11122-01 1100B MX-B1101/1,2 CL Feed EV Automatic Valve CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
137 EV-B1103 DGA-11122-01 1100B CL Line N3 Feed EV Automatic Valve N3 Gas 37.05 Nm3/h 28.5 Nm3/h 8.55 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
138 EV-B1104 DGA-11122-01 1100B RG Line MT Feed EV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
HF-B1101/1,2,3,4,5,6,7 MT Feed
139 EV-B1105 DGA-11122-01 1100B Automatic Valve MT Gas 140.4 Nm3/h 108.0 Nm3/h 32.4 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
EV
140 FG-B1102 DGA-11122-01 1100B CL Line N3 Feed Flow Area Flowmeter N3 Gas 37.05 Nm3/h 28.5 Nm3/h 8.55 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
141 FI-B1101 DGA-11122-01 1100B MX-B1101/1,2 CL Feed Flow Flowmeter CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
142 FI-B1103 DGA-11122-01 1100B RCL Line to OSBL Flow Flowmeter RCL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
143 FI-B1104 DGA-11122-01 1100B MX-B1101/1 CL Feed Flow Flowmeter CL Gas 1262.235 Nm3/h 971.0 Nm3/h 291.285 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
144 FI-B1105 DGA-11122-01 1100B MX-B1101/2 CL Feed Flow Flowmeter CL Gas 1262.235 Nm3/h 971.0 Nm3/h 291.285 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
145 FI-B1109 DGA-11122-01 1100B MX-B1101/1,2 RG Feed Flow Flowmeter RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
146 FI-B1110 DGA-11122-01 1100B MX-B1101/1 RG Feed Flow Flowmeter RG Gas 5166.785 Nm3/h 3974.5 Nm3/h 1192.335 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
147 FI-B1111 DGA-11122-01 1100B MX-B1101/2 RG Feed Flow Flowmeter RG Gas 5166.785 Nm3/h 3974.5 Nm3/h 1192.335 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
148 FI-B1112 DGA-11122-01 1100B RE-B1101/1 RG Feed Flow Flowmeter RG Gas 1836.8 Nm3/h 1413.0 Nm3/h 423.8 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
149 FI-B1114 DGA-11122-01 1100B RE-B1101/2 RG Feed Flow Flowmeter RG Gas 1836.8 Nm3/h 1413.0 Nm3/h 423.8 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
150 FI-B1116 DGA-11122-01 1100B RE-B1101/3 RG Feed Flow Flowmeter RG Gas 1836.8 Nm3/h 1413.0 Nm3/h 423.8 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
4 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
151 FI-B1118 DGA-11122-01 1100B RE-B1101/4 RG Feed Flow Flowmeter RG Gas 1836.8 Nm3/h 1413.0 Nm3/h 423.8 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
152 FI-B1120 DGA-11122-01 1100B RE-B1101/5 RG Feed Flow Flowmeter RG Gas 1836.8 Nm3/h 1413.0 Nm3/h 423.8 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
153 FI-B1122 DGA-11122-01 1100B RE-B1101/6 RG Feed Flow Flowmeter RG Gas 1836.8 Nm3/h 1413.0 Nm3/h 423.8 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
154 FI-B1124 DGA-11122-01 1100B RE-B1101/7 RG Feed Flow Flowmeter RG Gas 1836.8 Nm3/h 1413.0 Nm3/h 423.8 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
155 FIC-B1102 DGA-11122-01 1100B MX-B1101/1,2 CL Feed Flow Flowmeter CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
157 FIC-B1106 DGA-11122-01 1100B RG Line MT Feed Flow Flowmeter MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
158 FIC-B1106V DGA-11122-01 1100B RG Line MT Feed Control Valve Control Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 1 kg/cm2 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
159 FIC-B1107 DGA-11122-01 1100B RG Line N3 Feed Flow Flowmeter N3 Gas 109.2 Nm3/h 84.0 Nm3/h 25.2 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
160 FIC-B1107V DGA-11122-01 1100B RG Line N3 Feed Control Valve Control Valve N3 Gas 109.2 Nm3/h 84.0 Nm3/h 25.2 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 2 kg/cm2 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
161 FIC-B1108 DGA-11122-01 1100B MX-B1101/1,2 RG Feed Flow Flowmeter RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
162 FIC-B1113 DGA-11122-01 1100B HF-B1101/1 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
163 FIC-B1115 DGA-11122-01 1100B HF-B1101/2 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
165 FIC-B1117 DGA-11122-01 1100B HF-B1101/3 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
167 FIC-B1119 DGA-11122-01 1100B HF-B1101/4 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
169 FIC-B1121 DGA-11122-01 1100B HF-B1101/5 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
171 FIC-B1123 DGA-11122-01 1100B HF-B1101/6 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
5 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
173 FIC-B1125 DGA-11122-01 1100B HF-B1101/7 MT Feed Flow Flowmeter MT Gas 18.2 Nm3/h 14.0 Nm3/h 4.2 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
175 HC-B1101V DGA-11122-01 1100B RCL Line to OSBL Control Valve Control Valve RCL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 0.05 kg/cm2 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
176 PG-B1101 DGA-11122-01 1100B MX-B1101/1,2 CL Feed Press. Pressure gauge CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
177 PG-B1102 DGA-11122-01 1100B MX-B1101/1,2 CL Feed Press. Pressure gauge CL Gas 2524.47 Nm3/h 1941.9 Nm3/h 582.57 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
178 PG-B1103 DGA-11122-01 1100B RG Line MT Feed Press. Pressure gauge MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
179 PG-B1104 DGA-11122-01 1100B MX-B1101/1,2 RG Feed Press. Pressure gauge RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
HF-B1101/1,2,3,4,5,6,7 MT Feed
180 PG-B1105 DGA-11122-01 1100B Pressure gauge MT Gas 140.4 Nm3/h 108.0 Nm3/h 32.4 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
Press.
181 PI-B1102 DGA-11122-01 1100B RG Line MT Feed Press. Pressure transmitter MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
182 PI-B1103 DGA-11122-01 1100B MX-B1101/1,2 RG Feed Press. Pressure transmitter RG Gas 10333.57 Nm3/h 7948.9 Nm3/h 2384.67 Nm3/h 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
183 PI-B1104 DGA-11122-01 1100B MX-B1101/1,2 RG Outlet Press. Pressure transmitter RG Gas 12858.04 Nm3/h 9890.8 Nm3/h 2967.24 Nm3/h 2.00 kgf/cm2G 0.80 kgf/cm2G 60.0 deg C 35.0 deg C 2.1 kg/Nm3 0.013 cP
MX-B1101/1,2 RG O2
184 QI-B1101 DGA-11122-01 1100B GAS detector(O2) RG Gas 6.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 35.0 deg C 1.8 kg/Nm3 0.013 cP
Concentration
220 XA-B1101 DGA-11122-01 1100B HF-B1101/1 Flame Detector Flame Detector AIR Gas - - - ATM ATM
221 XA-B1102 DGA-11122-01 1100B HF-B1101/2 Flame Detector Flame Detector AIR Gas - - - ATM ATM
222 XA-B1103 DGA-11122-01 1100B HF-B1101/3 Flame Detector Flame Detector AIR Gas - - - ATM ATM
223 XA-B1104 DGA-11122-01 1100B HF-B1101/4 Flame Detector Flame Detector AIR Gas - - - ATM ATM
224 XA-B1105 DGA-11122-01 1100B HF-B1101/5 Flame Detector Flame Detector AIR Gas - - - ATM ATM
225 XA-B1106 DGA-11122-01 1100B HF-B1101/6 Flame Detector Flame Detector AIR Gas - - - ATM ATM
226 XA-B1107 DGA-11122-01 1100B HF-B1101/7 Flame Detector Flame Detector AIR Gas - - - ATM ATM
227 FI-B1126 DGA-11122-02 1100B HE-B1101/1 SC Feed Flow Flowmeter SC Liquid 1716 kg/h 1320.0 kg/h 396 kg/h 8.00 kgf/cm2G 6.10 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
228 FI-B1127 DGA-11122-02 1100B HE-B1101/2 SC Feed Flow Flowmeter SC Liquid 1716 kg/h 1320.0 kg/h 396 kg/h 8.00 kgf/cm2G 6.10 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
229 FI-B1128 DGA-11122-02 1100B HE-B1101/3 SC Feed Flow Flowmeter SC Liquid 1716 kg/h 1320.0 kg/h 396 kg/h 8.00 kgf/cm2G 6.10 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
6 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
230 LG-B1101 DGA-11122-02 1100B HE-B1101/1 Level Level gauge SC Liquid - - - 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 134.0 deg C 931.1 kg/m3 0.21 cP
231 LG-B1102 DGA-11122-02 1100B HE-B1101/2 Level Level gauge SC Liquid - - - 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 134.0 deg C 931.1 kg/m3 0.268 cP
232 LG-B1103 DGA-11122-02 1100B HE-B1101/3 Level Level gauge SC Liquid - - - 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 134.0 deg C 931.1 kg/m3 0.268 cP
239 PG-B1106 DGA-11122-02 1100B FL-B1101/1,2 S2 Outlet Press. Pressure gauge S2 Vapor 3432 kg/h 2640.0 kg/h 792 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
240 PI-B1105 DGA-11122-02 1100B HE-B1101/1,2 RG Feed Press. Pressure transmitter RG Gas 12857.65 Nm3/h 9890.5 Nm3/h 2967.15 Nm3/h 2.00 kgf/cm2G 0.70 kgf/cm2G 500.0 deg C 420.0 deg C 2.1 kg/Nm3 0.268 cP
HE-B1102/1,2,3,4,5 RG Feed
241 PI-B1106 DGA-11122-02 1100B Pressure transmitter RG Gas 12857.65 Nm3/h 9890.5 Nm3/h 2967.15 Nm3/h 2.00 kgf/cm2G 0.65 kgf/cm2G 180.0 deg C 160.0 deg C 2.1 kg/Nm3 0.018 cP
Press.
242 PI-B1107 DGA-11122-02 1100B HE-B1103/1 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
243 PI-B1108 DGA-11122-02 1100B HE-B1103/2 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
244 PI-B1109 DGA-11122-02 1100B HE-B1103/3 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
245 PI-B1110 DGA-11122-02 1100B HE-B1103/4 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
246 PI-B1111 DGA-11122-02 1100B HE-B1103/5 RG Feed Press. Pressure transmitter RG Gas 2571.53 Nm3/h 1978.1 Nm3/h 593.43 Nm3/h 2.00 kgf/cm2G 0.60 kgf/cm2G 180.0 deg C 100.0 deg C 2.1 kg/Nm3 0.016 cP
HE-B1103/1,2,3,4,5 RG Outlet
247 PI-B1112 DGA-11122-02 1100B Pressure transmitter RG Gas 12857.65 Nm3/h 9890.5 Nm3/h 2967.15 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
Press.
248 SV-B1101 DGA-11122-02 1100B RG Line RCL Outlet SV Automatic Valve RCL Gas 2.00 kgf/cm2G 0.55 kgf/cm2G - 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
264 EV-1201 DGA-11220-01 1200 RE-1201 CL Feed EV Automatic Valve CL Gas 91 Nm3/h 70.0 Nm3/h 21 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
265 EV-1204 DGA-11220-01 1200 HE-1203 S2 Feed EV Automatic Valve S2 Vapor 1630.2 kg/h 1254.0 kg/h 376.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G - 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
266 EV-A1202 DGA-11220-01 1200 HE-1201 CM Feed SV Automatic Valve CM Liquid 6.383 m3/h 4.9 m3/h 1.473 m3/h 7.00 kgf/cm2G 2.50 kgf/cm2G - 60.0 deg C 40.0 deg C 1340.0 kg/m3 0.38 cP
7 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
267 EV-A1203 DGA-11220-01 1200 TK-1701 CM Feed SV Automatic Valve CM Liquid 6.383 m3/h 4.9 m3/h 1.473 m3/h 7.00 kgf/cm2G 2.50 kgf/cm2G - 60.0 deg C 40.0 deg C 1340.0 kg/m3 0.38 cP
268 EV-B1202 DGA-11220-01 1200 HE-1201 CM Feed EV Automatic Valve CM Liquid 6.383 m3/h 4.9 m3/h 1.473 m3/h 7.00 kgf/cm2G 2.50 kgf/cm2G - 60.0 deg C 40.0 deg C 1340.0 kg/m3 0.38 cP
269 EV-B1203 DGA-11220-01 1200 TK-1701 CM Feed EV Automatic Valve CM Liquid 6.383 m3/h 4.9 m3/h 1.473 m3/h 7.00 kgf/cm2G 2.50 kgf/cm2G - 60.0 deg C 40.0 deg C 1340.0 kg/m3 0.38 cP
270 FG-1201 DGA-11220-01 1200 RE-1201 CL Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
271 FG-1202 DGA-11220-01 1200 ML-1201/1,2, DW Feed Flow Area Flowmeter DW Liquid 2.275 m3/h 1.8 m3/h 0.525 m3/h 4.00 kgf/cm2G 2.55 kgf/cm2G 60.0 deg C 30.0 deg C 997.0 kg/m3 0.599 cP
272 FG-1203 DGA-11220-01 1200 ML-1201/3,4 DW Feed Flow Area Flowmeter DW Liquid 2.275 m3/h 1.8 m3/h 0.525 m3/h 4.00 kgf/cm2G 2.55 kgf/cm2G 60.0 deg C 30.0 deg C 997.0 kg/m3 0.599 cP
273 FG-1204 DGA-11220-01 1200 HE-1202 CM Feed Flow Area Flowmeter CM Liquid 14.898 m3/h 11.5 m3/h 3.438 m3/h 7.00 kgf/cm2G 4.97 kgf/cm2G 60.0 deg C 35.0 deg C 1345.0 kg/m3 0.4 cP
274 FI-1201 DGA-11220-01 1200 CL-1201 CM Feed Flow Flowmeter CM Liquid 12.259 m3/h 9.4 m3/h 2.829 m3/h 7.00 kgf/cm2G 2.50 kgf/cm2G 60.0 deg C 10.0 deg C 1396.0 kg/m3 0.507 cP
275 FI-1206 DGA-11220-01 1200 CL-1202 CM Feed Flow Flowmeter CM Liquid 3.965 m3/h 3.1 m3/h 0.915 m3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 1296.0 kg/m3 0.365 cP
276 FIC-1202 DGA-11220-01 1200 RE-1201 CL Feed Flow Flowmeter CL Gas 91 Nm3/h 70.0 Nm3/h 21 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
277 FIC-1202V DGA-11220-01 1200 RE-1201 CL Feed Control Valve Control Valve CL Gas 91 Nm3/h 70.0 Nm3/h 21 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 0.25 kg/cm2 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
278 FIC-1203 DGA-11220-01 1200 CL-1202 CM Feed Flow Flowmeter CM Liquid 14.898 m3/h 11.5 m3/h 3.438 m3/h 7.00 kgf/cm2G 4.97 kgf/cm2G 60.0 deg C 35.0 deg C 1345.0 kg/m3 0.4 cP
279 FIC-1204 DGA-11220-01 1200 HE-1203 S2 Feed Flow Flowmeter S2 Vapor 1630.2 kg/h 1254.0 kg/h 376.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
280 FIC-1204V DGA-11220-01 1200 HE-1203 S2 Feed Control Valve Control Valve S2 Vapor 1630.2 kg/h 1254.0 kg/h 376.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 0.05 kg/cm2 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
281 FIC-1205 DGA-11220-01 1200 RE-1201 CM Feed Flow Flowmeter CM Liquid 1.976 m3/h 1.5 m3/h 0.456 m3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 1296.0 kg/m3 0.365 cP
282 FIC-1205V DGA-11220-01 1200 RE-1201 CM Feed Control Valve Control Valve CM Liquid 1.976 m3/h 1.5 m3/h 0.456 m3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 0.5 kg/cm2 60.0 deg C 40.0 deg C 1296.0 kg/m3 0.365 cP
283 LA-1201H DGA-11220-01 1200 VE-1201 CM Level Level switch CM Liquid - - 1.50 kgf/cm2G 60.0 deg C 10.0 deg C
284 LA-1201L DGA-11220-01 1200 VE-1201 CM Level Level switch CM Liquid - - 1.50 kgf/cm2G 60.0 deg C 10.0 deg C
285 LG-1201 DGA-11220-01 1200 RE-1201 CM Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 35.0 deg C 1345.0 kg/m3 0.4 cP
286 LG-1203 DGA-11220-01 1200 CL-1202 CM Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 1.55 kgf/cm2G 90.0 deg C 77.0 deg C 1276.0 kg/m3 0.286 cP
287 LG-1211 DGA-11220-01 1200 TK-1211 DW Level Level gauge DW Liquid - - - F.L ATM 60.0 deg C 29.9 deg C 997.0 kg/m3 0.599 cP
8 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
289 LIC-1201V DGA-11220-01 1200 CL-1202 CM Feed Control Valve Control Valve CM Liquid 14.898 m3/h 11.5 m3/h 3.438 m3/h 7.00 kgf/cm2G 4.97 kgf/cm2G 0.5 kg/cm2 60.0 deg C 35.0 deg C 1345.0 kg/m3 0.4 cP
291 LIC-1203V DGA-11220-01 1200 PU-1202 CM Feed Control Valve Control Valve CM Liquid 12.792 m3/h 9.8 m3/h 2.952 m3/h 4.00 kgf/cm2G 2.87 kgf/cm2G 0.5 kg/cm2 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.382 cP
292 LIC-1211 DGA-11220-01 1200 TK-1211 DW Level Liquid level TransmitterDW Liquid - - - F.L ATM 60.0 deg C 29.9 deg C 997.0 kg/m3 0.599 cP
293 LIC-1211V DGA-11220-01 1200 TK-1211 DW Feed Control Valve Control Valve DW Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 3 kg/cm2 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
294 PG-1201 DGA-11220-01 1200 RE-1201 CL Feed Press. Pressure gauge CL Gas 91 Nm3/h 70.0 Nm3/h 21 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
295 PG-1202 DGA-11220-01 1200 RE-1201 CL Feed Press. Pressure gauge CL Gas 91 Nm3/h 70.0 Nm3/h 21 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
296 PG-1203 DGA-11220-01 1200 CL-1201 CM Feed Press. Pressure gauge CM Vapor 237.497 Nm3/h 182.7 Nm3/h 54.807 Nm3/h 4.00 kgf/cm2G 1.20 kgf/cm2G 60.0 deg C 45.0 deg C 2.4 kg/Nm3 0.014 cP
297 PG-1204A DGA-11220-01 1200 PU-1201/A CM Discharge Press. Pressure gauge CM Liquid 14.898 m3/h 11.5 m3/h 3.438 m3/h 7.00 kgf/cm2G 4.97 kgf/cm2G 60.0 deg C 35.0 deg C 1345.0 kg/m3 0.4 cP
298 PG-1204B DGA-11220-01 1200 PU-1201/B CM Discharge Press. Pressure gauge CM Liquid 14.898 m3/h 11.5 m3/h 3.438 m3/h 7.00 kgf/cm2G 4.97 kgf/cm2G 60.0 deg C 35.0 deg C 1345.0 kg/m3 0.4 cP
299 PG-1205 DGA-11220-01 1200 CL-1202 CM Mid Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 1.55 kgf/cm2G 90.0 deg C 77.0 deg C 3.8 kg/Nm3 0.012 cP
300 PG-1206 DGA-11220-01 1200 HE-1203 S2 Feed Press. Pressure gauge S2 Vapor 1630.2 kg/h 1254.0 kg/h 376.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
301 PG-1207A DGA-11220-01 1200 PU-1202/A CM Discharge Press. Pressure gauge CM Liquid 12.792 m3/h 9.8 m3/h 2.952 m3/h 4.00 kgf/cm2G 2.87 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.382 cP
302 PG-1207B DGA-11220-01 1200 PU-1202/B CM Discharge Press. Pressure gauge CM Liquid 12.792 m3/h 9.8 m3/h 2.952 m3/h 4.00 kgf/cm2G 2.87 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.382 cP
303 PG-1208 DGA-11220-01 1200 RE-1201 CM Top Press. Pressure gauge CM Vapor - - - 4.00 kgf/cm2G 1.20 kgf/cm2G 60.0 deg C 45.0 deg C 2.4 kg/Nm3 0.014 cP
304 PG-1209 DGA-11220-01 1200 HE-1203 CM Feed Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 1.55 kgf/cm2G 90.0 deg C 77.0 deg C 3.8 kg/Nm3 0.012 cP
305 PG-1210 DGA-11220-01 1200 VE-1201 CM Feed Press. Pressure gauge CM Vapor 101.79 Nm3/h 78.3 Nm3/h 23.49 Nm3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 10.0 deg C 1.9 kg/Nm3 0.013 cP
306 PG-1211A DGA-11220-01 1200 PU-1211/A DW Discharge Press. Pressure gauge DW Liquid 4.55 m3/h 3.5 m3/h 1.05 m3/h 4.00 kgf/cm2G 2.55 kgf/cm2G 60.0 deg C 29.9 deg C 997.0 kg/m3 0.599 cP
307 PG-1211B DGA-11220-01 1200 PU-1211/B DW Discharge Press. Pressure gauge DW Liquid 4.55 m3/h 3.5 m3/h 1.05 m3/h 4.00 kgf/cm2G 2.55 kgf/cm2G 60.0 deg C 29.9 deg C 997.0 kg/m3 0.599 cP
308 PI-1201 DGA-11220-01 1200 RE-1201 CL Feed Press. Pressure transmitter CL Gas 91 Nm3/h 70.0 Nm3/h 21 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 3.2 kg/Nm3 0.014 cP
309 PI-1202 DGA-11220-01 1200 CL-1201 Top CM Press. Pressure transmitter CM Vapor 101.79 Nm3/h 78.3 Nm3/h 23.49 Nm3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 10.0 deg C 1.9 kg/Nm3 0.013 cP
310 PI-1204 DGA-11220-01 1200 CL-1202 CM Mid Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 1.55 kgf/cm2G 90.0 deg C 77.0 deg C 3.8 kg/Nm3 0.012 cP
9 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
311 PI-1205 DGA-11220-01 1200 CL-1202 Top CM Press. Pressure transmitter CM Vapor 2120.43 Nm3/h 1631.1 Nm3/h 489.33 Nm3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 90.0 deg C 70.0 deg C 3.8 kg/Nm3 0.012 cP
312 PIC-1203 DGA-11220-01 1200 RE-1201 CM TOP Press. Pressure transmitter CM Vapor 237.497 Nm3/h 182.7 Nm3/h 54.807 Nm3/h 4.00 kgf/cm2G 1.20 kgf/cm2G 60.0 deg C 45.0 deg C 2.4 kg/Nm3 0.014 cP
314 SV-A1201 DGA-11220-01 1200 VE-A1301 HA Feed SV Automatic Valve HA Vapor 50.96 Nm3/h 39.2 Nm3/h 11.76 Nm3/h 2.00 kgf/cm2G 1.50 kgf/cm2G - 60.0 deg C 10.0 deg C 1.9 kg/m3 0.013 cP
315 SV-B1201 DGA-11220-01 1200 VE-B1301 HA Feed SV Automatic Valve HA Vapor 50.96 Nm3/h 39.2 Nm3/h 11.76 Nm3/h 2.00 kgf/cm2G 1.50 kgf/cm2G - 60.0 deg C 10.0 deg C 1.9 kg/m3 0.013 cP
332 TIC-1210V DGA-11220-01 1200 HE-1202 CM Feed Control Valve Control Valve CM Liquid 13 t/h 10.0 t/h 3 t/h 7.00 kgf/cm2G 4.97 kgf/cm2G 0.5 kg/cm2 60.0 deg C 35.0 deg C 1345.0 kg/m3 0.4 cP
333 EV-A1301 DGA-11321-01 1300A TK-A1301 CHA Outlet EV Automatic Valve CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 2.00 kgf/cm2G 0.45 kgf/cm2G - 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
334 EV-A1302 DGA-11321-01 1300A TK-A1302 DHA Outlet EV Automatic Valve DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 2.00 kgf/cm2G 0.08 kgf/cm2G - 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
335 EV-A1303 DGA-11321-01 1300A TK-A1302 DHA Outlet EV Automatic Valve DHA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 2.00 kgf/cm2G 0.08 kgf/cm2G - 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
342 FG-A1310 DGA-11321-01 1300A TK-A1302 CHA Feed Flow Area Flowmeter CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
343 FI-A1301 DGA-11321-01 1300A CL-A1301/1 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
344 FI-A1302 DGA-11321-01 1300A CL-A1301/2 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
345 FI-A1303 DGA-11321-01 1300A CL-A1301/3 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
346 FI-A1304 DGA-11321-01 1300A CL-A1301/4 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
347 FI-A1305 DGA-11321-01 1300A CL-A1301/5 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
348 FI-A1306 DGA-11321-01 1300A CL-A1301/6 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
10 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
350 FIC-A1308 DGA-11321-01 1300A CL-A1302/1 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
352 FIC-A1309 DGA-11321-01 1300A CL-A1302/2 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
354 FIC-A1310 DGA-11321-01 1300A CL-A1302/3 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
356 FIC-A1311 DGA-11321-01 1300A CL-A1302/4 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
358 FIC-A1312 DGA-11321-01 1300A CL-A1302/5 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
360 FIC-A1313 DGA-11321-01 1300A CL-A1302/6 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
362 LA-A1305H DGA-11321-01 1300A TK-A1304 Level Level switch CM Liquid - - - 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
363 LA-A1305L DGA-11321-01 1300A TK-A1304 Level Level switch CM Liquid - - - 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
364 LG-A1301 DGA-11321-01 1300A TK-A1301 Level Level gauge CHA Liquid - - - 2.00 kgf/cm2G 0.45 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
365 LG-A1302 DGA-11321-01 1300A TK-A1302 Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.08 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
366 LG-A1303 DGA-11321-01 1300A TS-A1301 Level Level gauge CHA Liquid - - - 2.00 kgf/cm2G 0.45 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
367 LG-A1307 DGA-11321-01 1300A TK-A1304 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
11 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
371 PG-A1301A DGA-11321-01 1300A PU-A1301/A Discharge Press. Pressure gauge CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
372 PG-A1301B DGA-11321-01 1300A PU-A1301/B Discharge Press. Pressure gauge CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
373 PG-A1302A DGA-11321-01 1300A PU-A1302/A Discharge Press. Pressure gauge DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
374 PG-A1302B DGA-11321-01 1300A PU-A1302/B Discharge Press. Pressure gauge DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
375 PG-A1310 DGA-11321-01 1300A PU-A1305 Discharge Press. Pressure gauge CM Liquid 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
CL-A1301/1,2,3,4,5,6 RG Feed
376 PI-A1301 DGA-11321-01 1300A Pressure transmitter RG Gas 12908.61 Nm3/h 9929.7 Nm3/h 2978.91 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
Press.
377 PI-A1302 DGA-11321-01 1300A CL-A1301/1 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
378 PI-A1303 DGA-11321-01 1300A CL-A1301/2 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
379 PI-A1304 DGA-11321-01 1300A CL-A1301/3 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
380 PI-A1305 DGA-11321-01 1300A CL-A1301/4 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
381 PI-A1306 DGA-11321-01 1300A CL-A1301/5 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
382 PI-A1307 DGA-11321-01 1300A CL-A1301/6 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
383 PIC-A1308 DGA-11321-01 1300A PU-A1302/B Discharge Press. Pressure transmitter DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
401 EV-B1301 DGA-11322-01 1300B TK-B1301 CHA Outlet EV Automatic Valve CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 2.00 kgf/cm2G 0.45 kgf/cm2G - 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
402 EV-B1302 DGA-11322-01 1300B TK-B1302 DHA Outlet EV Automatic Valve DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 2.00 kgf/cm2G 0.08 kgf/cm2G - 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
12 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
403 EV-B1303 DGA-11322-01 1300B TK-B1302 DHA Outlet EV Automatic Valve DHA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 2.00 kgf/cm2G 0.08 kgf/cm2G - 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
410 FG-B1310 DGA-11322-01 1300B TK-B1302 CHA Feed Flow Area Flowmeter CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
411 FI-B1301 DGA-11322-01 1300B CL-B1301/1 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
412 FI-B1302 DGA-11322-01 1300B CL-B1301/2 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
413 FI-B1303 DGA-11322-01 1300B CL-B1301/3 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
414 FI-B1304 DGA-11322-01 1300B CL-B1301/4 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
415 FI-B1305 DGA-11322-01 1300B CL-B1301/5 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
416 FI-B1306 DGA-11322-01 1300B CL-B1301/6 RG Feed Flow Flowmeter RG Gas 2151.435 Nm3/h 1655.0 Nm3/h 496.485 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
418 FIC-B1308 DGA-11322-01 1300B CL-B1302/1 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
420 FIC-B1309 DGA-11322-01 1300B CL-B1302/2 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
422 FIC-B1310 DGA-11322-01 1300B CL-B1302/3 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
424 FIC-B1311 DGA-11322-01 1300B CL-B1302/4 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
13 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
426 FIC-B1312 DGA-11322-01 1300B CL-B1302/5 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
428 FIC-B1313 DGA-11322-01 1300B CL-B1302/6 DHA Feed Flow Flowmeter DHA Liquid 2.99 m3/h 2.3 m3/h 0.69 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
430 LA-B1305H DGA-11322-01 1300B TK-B1304 Level Level switch CM Liquid - - - 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
431 LA-B1305L DGA-11322-01 1300B TK-B1304 Level Level switch CM Liquid - - - 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
432 LG-B1301 DGA-11322-01 1300B TK-B1301 Level Level gauge CHA Liquid - - - 2.00 kgf/cm2G 0.45 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
433 LG-B1302 DGA-11322-01 1300B TK-B1302 Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.08 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
434 LG-B1303 DGA-11322-01 1300B TS-B1301 Level Level gauge CHA Liquid - - - 2.00 kgf/cm2G 0.45 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
435 LG-B1307 DGA-11322-01 1300B TK-B1304 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
439 PG-B1301A DGA-11322-01 1300B PU-B1301/A Discharge Press. Pressure gauge CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
440 PG-B1301B DGA-11322-01 1300B PU-B1301/B DischBrge Press. Pressure gBuge CHA Liquid 19.37 m3/h 14.9 m3/h 4.47 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
441 PG-B1302A DGA-11322-01 1300B PU-B1302/A Discharge Press. Pressure gauge DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
442 PG-B1302B DGA-11322-01 1300B PU-B1302/B Discharge Press. Pressure gauge DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
443 PG-B1310 DGA-11322-01 1300B PU-B1305 Discharge Press. Pressure gauge CM Liquid 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
CL-B1301/1,2,3,4,5,6 RG Feed
444 PI-B1301 DGA-11322-01 1300B Pressure transmitter RG Gas 12908.61 Nm3/h 9929.7 Nm3/h 2978.91 Nm3/h 2.00 kgf/cm2G 0.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.1 kg/Nm3 0.013 cP
Press.
445 PI-B1302 DGA-11322-01 1300B CL-B1301/1 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
446 PI-B1303 DGA-11322-01 1300B CL-B1301/2 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
14 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
447 PI-B1304 DGA-11322-01 1300B CL-B1301/3 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
448 PI-B1305 DGA-11322-01 1300B CL-B1301/4 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
449 PI-B1306 DGA-11322-01 1300B CL-B1301/5 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
450 PI-B1307 DGA-11322-01 1300B CL-B1301/6 RG Top Press. Pressure transmitter RG Gas 1963.78 Nm3/h 1510.6 Nm3/h 453.18 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 100.0 deg C 60.0 deg C 2.1 kg/Nm3 0.014 cP
451 PIC-B1308 DGA-11322-01 1300B PU-B1302/B Discharge Press. Pressure transmitter DHA Liquid 24.57 m3/h 18.9 m3/h 5.67 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
469 EV-1304 DGA-11323-01 1300 TK-1303 CHA Outlet EV Automatic Valve CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 2.00 kgf/cm2G 0.10 kgf/cm2G - 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
470 FG-1308 DGA-11323-01 1300 TK-1303 CHA Feed Flow Area Flowmeter CHA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
471 FG-1309 DGA-11323-01 1300 CL-1304 DHA Feed Flow Area Flowmeter DHA Liquid 6.63 m3/h 5.1 m3/h 1.53 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 60.0 deg C 35.0 deg C 1065.0 kg/m3 0.869 cP
472 FG-1311 DGA-11323-01 1300 CL-1304 DHA Circulation Flow Area Flowmeter DHA Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 60.0 deg C 35.0 deg C 1066.0 kg/m3 0.872 cP
473 FG-A1307 DGA-11323-01 1300 TK-A1301 CHA Feed Flow Area Flowmeter CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
474 FG-B1307 DGA-11323-01 1300 TK-B1301 CHA Feed Flow Area Flowmeter CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
475 FI-A1314 DGA-11323-01 1300 HE-1303 CHA Feed Flow Flowmeter CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
476 FI-B1314 DGA-11323-01 1300 HE-1303 CHA Feed Flow Flowmeter CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
477 FIC-1315 DGA-11323-01 1300 CL-1303 AIR Feed Flow Flowmeter AIR Gas 897.78 Nm3/h 690.6 Nm3/h 207.18 Nm3/h 0.50 kgf/cm2G 0.10 kgf/cm2G 60.0 deg C 40.0 deg C 1.3 kg/Nm3 0.019 cP
478 FIC-1315V DGA-11323-01 1300 AIR Feed Control Valve Control Valve AIR Gas 269.334 Nm3/h 207.2 Nm3/h 62.154 Nm3/h 0.50 kgf/cm2G 0.10 kgf/cm2G 0.05 kg/cm2 60.0 deg C 40.0 deg C 1.3 kg/Nm3 0.019 cP
15 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
479 LG-1304 DGA-11323-01 1300 TK-1303 Level Level gauge CHA Liquid - - - 2.00 kgf/cm2G 0.10 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
480 LG-1305 DGA-11323-01 1300 CL-1303 Level Level gauge CHA Liquid - - - 0.40 kgf/cm2G 0.10 kgf/cm2G 60.0 deg C 15.0 deg C 1153.0 kg/m3 1.916 cP
481 LG-1306 DGA-11323-01 1300 CL-1304 Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.08 kgf/cm2G 60.0 deg C 35.0 deg C 1066.0 kg/m3 0.872 cP
488 PG-1305 DGA-11323-01 1300 CL-1303 CM Outlet Press. Pressure gauge CM Vapor 903.5 Nm3/h 695.0 Nm3/h 208.5 Nm3/h 2.00 kgf/cm2G 0.08 kgf/cm2G 60.0 deg C 5.0 deg C 1.3 kg/Nm3 0.017 cP
489 PG-1306 DGA-11323-01 1300 CL-1304 CM Outlet Press. Pressure gauge CM Vapor 9347 Nm3/h 7190.0 Nm3/h 2157 Nm3/h 2.00 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 35.0 deg C 1.3 kg/Nm3 0.019 cP
490 PG-1307 DGA-11323-01 1300 CL-1303 AIR Feed Press. Pressure gauge AIR Gas 897.78 Nm3/h 690.6 Nm3/h 207.18 Nm3/h 0.50 kgf/cm2G 0.10 kgf/cm2G 60.0 deg C 40.0 deg C 1.3 kg/Nm3 0.019 cP
491 PG-1308A DGA-11323-01 1300 PU-1303/A Discharge Press. Pressure gauge CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
492 PG-1308B DGA-11323-01 1300 PU-1303/B Discharge Press. Pressure gauge CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
493 PG-1309A DGA-11323-01 1300 PU-1304/A Discharge Press. Pressure gauge DHA Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 60.0 deg C 35.0 deg C 1066.0 kg/m3 0.872 cP
494 PG-1309B DGA-11323-01 1300 PU-1304/B Discharge Press. Pressure gauge DHA Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 60.0 deg C 35.0 deg C 1066.0 kg/m3 0.872 cP
495 QI-1307 DGA-11323-01 1300 TK-1303 CHA Density Densitometer CHA Liquid 5.00 kgf/cm2G 3.23 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
499 FG-A1401 DGA-11421-01 1400A CL-A1402 Top PW Feed Flow Area Flowmeter PW Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
501 FI-A1401 DGA-11421-01 1400A HE-A1401/1,2 DHA Feed Flow Flowmeter DHA Liquid 52.78 m3/h 40.6 m3/h 12.18 m3/h 5.00 kgf/cm2G 3.78 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
502 FI-A1402 DGA-11421-01 1400A HE-A1403 CS Feed Flow Flowmeter WCS Liquid 48.1 m3/h 37.0 m3/h 11.1 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
503 FI-A1403 DGA-11421-01 1400A HE-A1404 CS Feed Flow Flowmeter CS Liquid 50.96 m3/h 39.2 m3/h 11.76 m3/h 5.00 kgf/cm2G 3.42 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
16 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
504 FIC-A1404 DGA-11421-01 1400A CL-A1403 CS Feed Flow Flowmeter CS Liquid 0.39 m3/h 0.3 m3/h 0.09 m3/h 7.00 kgf/cm2G 5.14 kgf/cm2G 60.0 deg C 35.0 deg C 1267.0 kg/m3 4.181 cP
506 LG-A1401 DGA-11421-01 1400A CL-A1401 Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.45 kgf/cm2G 60.0 deg C 49.0 deg C 1058.0 kg/m3 0.697 cP
507 LG-A1402 DGA-11421-01 1400A CL-A1402 Level Level gauge WCS Liquid - - - 2.00 kgf/cm2G 0.35 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
508 LG-A1403 DGA-11421-01 1400A CL-A1403 Level Level gauge CS Liquid - - - 2.00 kgf/cm2G 0.30 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
515 PdG-A1402 DGA-11421-01 1400A FL-A1401 Differential Press. Differential press. Gauge
RG Gas 10711.48 Nm3/h 8239.6 Nm3/h 2471.88 Nm3/h 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 35.0 deg C 2.2 kg/Nm3 0.013 cP
516 PG-A1401A DGA-11421-01 1400A PU-A1401/A Discharge Press. Pressure gauge DHA Liquid 52.78 m3/h 40.6 m3/h 12.18 m3/h 5.00 kgf/cm2G 3.78 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
517 PG-A1401B DGA-11421-01 1400A PU-A1401/B Discharge Press. Pressure gauge DHA Liquid 52.78 m3/h 40.6 m3/h 12.18 m3/h 5.00 kgf/cm2G 3.78 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
518 PG-A1403A DGA-11421-01 1400A PU-A1402/A Discharge Press. Pressure gauge WCS Liquid 48.1 m3/h 37.0 m3/h 11.1 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
519 PG-A1403B DGA-11421-01 1400A PU-A1402/B Discharge Press. Pressure gauge WCS Liquid 48.1 m3/h 37.0 m3/h 11.1 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
520 PG-A1404A DGA-11421-01 1400A PU-A1403/A Discharge Press. Pressure gauge CS Liquid 50.96 m3/h 39.2 m3/h 11.76 m3/h 5.00 kgf/cm2G 3.42 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
521 PG-A1404B DGA-11421-01 1400A PU-A1403/B Discharge Press. Pressure gauge CS Liquid 50.96 m3/h 39.2 m3/h 11.76 m3/h 5.00 kgf/cm2G 3.42 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
522 PI-A1401 DGA-11421-01 1400A CL-A1401 RG Feed Press. Pressure transmitter RG Gas 11705.46 Nm3/h 9004.2 Nm3/h 2701.26 Nm3/h 2.00 kgf/cm2G 0.45 kgf/cm2G 60.0 deg C 60.0 deg C 0.0 kg/Nm3 0.014 cP
523 PI-A1402 DGA-11421-01 1400A CL-A1401 RG TOP Press. Pressure transmitter RG Gas 10711.48 Nm3/h 8239.6 Nm3/h 2471.88 Nm3/h 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 35.0 deg C 2.2 kg/Nm3 0.013 cP
524 PI-A1403 DGA-11421-01 1400A CL-A1402 RG Feed Press. Pressure transmitter RG Gas 10711.48 Nm3/h 8239.6 Nm3/h 2471.88 Nm3/h 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 35.0 deg C 2.2 kg/Nm3 0.013 cP
525 PI-A1404 DGA-11421-01 1400A CL-A1402 RG TOP Press. Pressure transmitter RG Gas 10673.52 Nm3/h 8210.4 Nm3/h 2463.12 Nm3/h 2.00 kgf/cm2G 0.34 kgf/cm2G 60.0 deg C 30.0 deg C 2.2 kg/Nm3 0.013 cP
17 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
526 PI-A1405 DGA-11421-01 1400A CL-A1403 RG TOP Press. Pressure transmitter RG Gas 10526.36 Nm3/h 8097.2 Nm3/h 2429.16 Nm3/h 2.00 kgf/cm2G 0.30 kgf/cm2G 60.0 deg C 25.0 deg C 2.2 kg/Nm3 0.012 cP
527 SV-A1401 DGA-11421-01 1400A CL-A1403 CS Feed SV Automatic Valve CS Liquid 0.39 m3/h 0.3 m3/h 0.09 m3/h 7.00 kgf/cm2G 5.14 kgf/cm2G - 60.0 deg C 35.0 deg C 1267.0 kg/m3 4.181 cP
528 SV-A1402 DGA-11421-01 1400A CL-A1402 Top PW Feed SV Automatic Valve PW Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
529 SV-A1403 DGA-11421-01 1400A TK-1901 WCS Feed SV Automatic Valve WCS Liquid 0.52 m3/h 0.4 m3/h 0.12 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G - 60.0 deg C 30.8 deg C 1193.0 kg/m3 1.649 cP
538 FG-A1404 DGA-11421-02 1400A QIC-A1401 SA Feed Flow Area Flowmeter SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
539 FI-A1405 DGA-11421-02 1400A HE-A1405 SA Feed Flow Flowmeter SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
540 FI-A1406 DGA-11421-02 1400A HE-A1406 SA Feed Flow Flowmeter SA Liquid 52.26 m3/h 40.2 m3/h 12.06 m3/h 6.00 kgf/cm2G 4.05 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
541 FI-A1407 DGA-11421-02 1400A CL-A1406 SA Feed Flow Flowmeter SA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 5.00 kgf/cm2G 3.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
542 FI-A1408 DGA-11421-02 1400A CL-A1406 SA Feed Flow Flowmeter SA Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G 60.0 deg C 35.0 deg C 1813.0 kg/m3 18.5 cP
543 LG-A1404 DGA-11421-02 1400A CL-A1404 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.25 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
544 LG-A1405 DGA-11421-02 1400A CL-A1405 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.20 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
545 LG-A1406 DGA-11421-02 1400A CL-A1406 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
546 LG-A1407 DGA-11421-02 1400A FL-A1402 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
547 LG-A1408 DGA-11421-02 1400A TS-A1401 SA Level Level gauge SA Liquid - - - F.L ATM 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
553 PdG-A1408 DGA-11421-02 1400A FL-A1402 Differential Press. Differential press. Gauge
RG Gas 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
554 PG-A1405A DGA-11421-02 1400A PU-A1404/A Discharge Press. Pressure gauge SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
555 PG-A1405B DGA-11421-02 1400A PU-A1404/B Discharge Press. Pressure gauge SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
18 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
556 PG-A1406A DGA-11421-02 1400A PU-A1405/A Discharge Press. Pressure gauge SA Liquid 52.26 m3/h 40.2 m3/h 12.06 m3/h 6.00 kgf/cm2G 4.05 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
557 PG-A1406B DGA-11421-02 1400A PU-A1405/B Discharge Press. Pressure gauge SA Liquid 52.26 m3/h 40.2 m3/h 12.06 m3/h 6.00 kgf/cm2G 4.05 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
558 PG-A1407A DGA-11421-02 1400A PU-A1406/A Discharge Press. Pressure gauge SA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 5.00 kgf/cm2G 3.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
559 PG-A1407B DGA-11421-02 1400A PU-A1406/B Discharge Press. Pressure gauge SA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 5.00 kgf/cm2G 3.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
560 PI-A1406 DGA-11421-02 1400A CL-A1405 RG Feed Press. Pressure transmitter RG Gas 10361 Nm3/h 7970.0 Nm3/h 2391 Nm3/h 2.00 kgf/cm2G 0.25 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
561 PI-A1407 DGA-11421-02 1400A CL-A1405 TOP RG Press. Pressure transmitter RG Gas 10338.64 Nm3/h 7952.8 Nm3/h 2385.84 Nm3/h 2.00 kgf/cm2G 0.20 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
562 PI-A1408 DGA-11421-02 1400A CL-A1406 TOP RG Press. Pressure transmitter RG Gas 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
563 QIC-A1401 DGA-11421-02 1400A CL-A1404 SA Feed Density Densitometer SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
565 SV-A1404 DGA-11421-02 1400A CL-A1406 SA Feed SV Automatic Valve SA Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G - 60.0 deg C 35.0 deg C 1813.0 kg/m3 18.5 cP
566 SV-A1405 DGA-11421-02 1400A TK-3009 WSA Feed SV Automatic Valve WSA Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
570 FG-B1401 DGA-11422-01 1400B CL-B1402 Top PW Feed Flow Area Flowmeter PW Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
572 FI-B1401 DGA-11422-01 1400B HE-B1401/1,2 DHA Feed Flow Flowmeter DHA Liquid 52.78 m3/h 40.6 m3/h 12.18 m3/h 5.00 kgf/cm2G 3.78 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
573 FI-B1402 DGA-11422-01 1400B HE-B1403 CS Feed Flow Flowmeter WCS Liquid 48.1 m3/h 37.0 m3/h 11.1 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
574 FI-B1403 DGA-11422-01 1400B HE-B1404 CS Feed Flow Flowmeter CS Liquid 50.96 m3/h 39.2 m3/h 11.76 m3/h 5.00 kgf/cm2G 3.42 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
575 FIC-B1404 DGA-11422-01 1400B CL-B1403 CS Feed Flow Flowmeter CS Liquid 0.39 m3/h 0.3 m3/h 0.09 m3/h 7.00 kgf/cm2G 5.14 kgf/cm2G 60.0 deg C 35.0 deg C 1267.0 kg/m3 4.181 cP
577 LG-B1401 DGA-11422-01 1400B CL-B1401 Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.45 kgf/cm2G 60.0 deg C 49.0 deg C 1058.0 kg/m3 0.697 cP
578 LG-B1402 DGA-11422-01 1400B CL-B1402 Level Level gauge WCS Liquid - - - 2.00 kgf/cm2G 0.35 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
579 LG-B1403 DGA-11422-01 1400B CL-B1403 Level Level gauge CS Liquid - - - 2.00 kgf/cm2G 0.30 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
19 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
586 PdG-B1402 DGA-11422-01 1400B FL-B1401 Differential Press. Differential press. Gauge
RG Gas 10711.48 Nm3/h 8239.6 Nm3/h 2471.88 Nm3/h 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 35.0 deg C 2.2 kg/Nm3 0.013 cP
587 PG-B1401A DGA-11422-01 1400B PU-B1401/A Discharge Press. Pressure gauge DHA Liquid 52.78 m3/h 40.6 m3/h 12.18 m3/h 5.00 kgf/cm2G 3.78 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
588 PG-B1401B DGA-11422-01 1400B PU-B1401/B Discharge Press. Pressure gauge DHA Liquid 52.78 m3/h 40.6 m3/h 12.18 m3/h 5.00 kgf/cm2G 3.78 kgf/cm2G 60.0 deg C 44.7 deg C 1061.0 kg/m3 0.747 cP
589 PG-B1403A DGA-11422-01 1400B PU-B1402/A Discharge Press. Pressure gauge WCS Liquid 48.1 m3/h 37.0 m3/h 11.1 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
590 PG-B1403B DGA-11422-01 1400B PU-B1402/B Discharge Press. Pressure gauge WCS Liquid 48.1 m3/h 37.0 m3/h 11.1 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G 60.0 deg C 30.8 deg C 1194.0 kg/m3 1.658 cP
591 PG-B1404A DGA-11422-01 1400B PU-B1403/A Discharge Press. Pressure gauge CS Liquid 50.96 m3/h 39.2 m3/h 11.76 m3/h 5.00 kgf/cm2G 3.42 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
592 PG-B1404B DGA-11422-01 1400B PU-B1403/B Discharge Press. Pressure gauge CS Liquid 50.96 m3/h 39.2 m3/h 11.76 m3/h 5.00 kgf/cm2G 3.42 kgf/cm2G 60.0 deg C 26.9 deg C 1245.0 kg/m3 4.047 cP
593 PI-B1401 DGA-11422-01 1400B CL-B1401 RG Feed Press. Pressure transmitter RG Gas 11705.46 Nm3/h 9004.2 Nm3/h 2701.26 Nm3/h 2.00 kgf/cm2G 0.45 kgf/cm2G 60.0 deg C 60.0 deg C 0.0 kg/Nm3 0.014 cP
594 PI-B1402 DGA-11422-01 1400B CL-B1401 RG TOP Press. Pressure transmitter RG Gas 10711.48 Nm3/h 8239.6 Nm3/h 2471.88 Nm3/h 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 35.0 deg C 2.2 kg/Nm3 0.013 cP
595 PI-B1403 DGA-11422-01 1400B CL-B1402 RG Feed Press. Pressure transmitter RG Gas 10711.48 Nm3/h 8239.6 Nm3/h 2471.88 Nm3/h 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 35.0 deg C 2.2 kg/Nm3 0.013 cP
596 PI-B1404 DGA-11422-01 1400B CL-B1402 RG TOP Press. Pressure transmitter RG Gas 10673.52 Nm3/h 8210.4 Nm3/h 2463.12 Nm3/h 2.00 kgf/cm2G 0.34 kgf/cm2G 60.0 deg C 30.0 deg C 2.2 kg/Nm3 0.013 cP
597 PI-B1405 DGA-11422-01 1400B CL-B1403 RG TOP Press. Pressure transmitter RG Gas 10526.36 Nm3/h 8097.2 Nm3/h 2429.16 Nm3/h 2.00 kgf/cm2G 0.30 kgf/cm2G 60.0 deg C 25.0 deg C 2.2 kg/Nm3 0.012 cP
598 SV-B1401 DGA-11422-01 1400B CL-B1403 CS Feed SV Automatic Valve CS Liquid 0.39 m3/h 0.3 m3/h 0.09 m3/h 7.00 kgf/cm2G 5.14 kgf/cm2G - 60.0 deg C 35.0 deg C 1267.0 kg/m3 4.181 cP
599 SV-B1402 DGA-11422-01 1400B CL-B1402 Top PW Feed SV Automatic Valve PW Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
600 SV-B1403 DGA-11422-01 1400B TK-1901 WCS Feed SV Automatic Valve WCS Liquid 0.52 m3/h 0.4 m3/h 0.12 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G - 60.0 deg C 30.8 deg C 1193.0 kg/m3 1.649 cP
609 FG-B1404 DGA-11422-02 1400B QIC-B1401 SA Feed Flow Area Flowmeter SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
610 FI-B1405 DGA-11422-02 1400B HE-B1405 SA Feed Flow Flowmeter SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
20 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
611 FI-B1406 DGA-11422-02 1400B HE-B1406 SA Feed Flow Flowmeter SA Liquid 52.26 m3/h 40.2 m3/h 12.06 m3/h 6.00 kgf/cm2G 4.05 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
612 FI-B1407 DGA-11422-02 1400B CL-B1406 SA Feed Flow Flowmeter SA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 5.00 kgf/cm2G 3.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
613 FI-B1408 DGA-11422-02 1400B CL-B1406 SA Feed Flow Flowmeter SA Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G 60.0 deg C 35.0 deg C 1813.0 kg/m3 18.5 cP
614 LG-B1404 DGA-11422-02 1400B CL-B1404 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.25 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
615 LG-B1405 DGA-11422-02 1400B CL-B1405 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.20 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
616 LG-B1406 DGA-11422-02 1400B CL-B1406 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
617 LG-B1407 DGA-11422-02 1400B FL-B1402 SA Level Level gauge SA Liquid - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
618 LG-B1408 DGA-11422-02 1400B TS-B1401 SA Level Level gauge SA Liquid - - - F.L ATM 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
624 PdG-B1408 DGA-11422-02 1400B FL-B1402 Differential Press. Differential press. Gauge
RG Gas 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
625 PG-B1405A DGA-11422-02 1400B PU-B1404/A Discharge Press. Pressure gauge SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
626 PG-B1405B DGA-11422-02 1400B PU-B1404/B Discharge Press. Pressure gauge SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
627 PG-B1406A DGA-11422-02 1400B PU-B1405/A Discharge Press. Pressure gauge SA Liquid 52.26 m3/h 40.2 m3/h 12.06 m3/h 6.00 kgf/cm2G 4.05 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
628 PG-B1406B DGA-11422-02 1400B PU-B1405/B Discharge Press. Pressure gauge SA Liquid 52.26 m3/h 40.2 m3/h 12.06 m3/h 6.00 kgf/cm2G 4.05 kgf/cm2G 60.0 deg C 40.3 deg C 1810.0 kg/m3 17.51 cP
629 PG-B1407A DGA-11422-02 1400B PU-B1406/A Discharge Press. Pressure gauge SA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 5.00 kgf/cm2G 3.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
630 PG-B1407B DGA-11422-02 1400B PU-B1406/B Discharge Press. Pressure gauge SA Liquid 52.52 m3/h 40.4 m3/h 12.12 m3/h 5.00 kgf/cm2G 3.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.05 cP
631 PI-B1406 DGA-11422-02 1400B CL-B1405 RG Feed Press. Pressure transmitter RG Gas 10361 Nm3/h 7970.0 Nm3/h 2391 Nm3/h 2.00 kgf/cm2G 0.25 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
632 PI-B1407 DGA-11422-02 1400B CL-B1405 TOP RG Press. Pressure transmitter RG Gas 10338.64 Nm3/h 7952.8 Nm3/h 2385.84 Nm3/h 2.00 kgf/cm2G 0.20 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
21 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
633 PI-B1408 DGA-11422-02 1400B CL-B1406 TOP RG Press. Pressure transmitter RG Gas 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
634 QIC-B1401 DGA-11422-02 1400B CL-B1404 SA Feed Density Densitometer SA Liquid 50.83 m3/h 39.1 m3/h 11.73 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
636 SV-B1404 DGA-11422-02 1400B CL-B1406 SA Feed SV Automatic Valve SA Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G - 60.0 deg C 35.0 deg C 1813.0 kg/m3 18.5 cP
637 SV-B1405 DGA-11422-02 1400B TK-3009 WSA Feed SV Automatic Valve WSA Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.0 kg/m3 5.509 cP
641 LG-A1501 DGA-11521-01 1500A VE-A1501 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
644 PdG-A1503 DGA-11521-01 1500A FL-A1501/A Differential Press. Differential press. Gauge
RG Gas 5169.3 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
645 PdG-A1504 DGA-11521-01 1500A FL-A1501/B Differential Press. Differential press. Gauge
RG Gas 5169.3 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
646 PdG-A1505 DGA-11521-01 1500A FL-A1501/C Differential Press. Differential press. Gauge
RG Gas 5169.3 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
647 PG-A1501 DGA-11521-01 1500A VE-A1501 Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 0.0 deg C 2.2 kg/Nm3 0.013 cP
648 PG-A1502A DGA-11521-01 1500A PU-A1501/A Discharge Press. Pressure gauge CM Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 9.00 kgf/cm2G 6.83 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
649 PG-A1502B DGA-11521-01 1500A PU-A1501/B Discharge Press. Pressure gauge CM Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 9.00 kgf/cm2G 6.83 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
650 PG-A1506 DGA-11521-01 1500A FL-A1501/A CM Outlet Press. Pressure gauge RG Vapor 5169.3 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
651 PG-A1507 DGA-11521-01 1500A FL-A1501/B CM Outlet Press. Pressure gauge RG Vapor 5169.3 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
652 PG-A1508 DGA-11521-01 1500A FL-A1501/C CM Outlet Press. Pressure gauge RG Vapor 5169.3 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
653 PIC-A1501 DGA-11521-01 1500A FL-A1501/A,B,C RG Feed Press. Pressure transmitter RG Gas 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
UN-A1501/A,B,C CM Outlet
654 PIC-A1502 DGA-11521-01 1500A Pressure transmitter CM Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 80.0 deg C 60.0 deg C 2.2 kg/Nm3 0.014 cP
Press.
656 SV-A1501 DGA-11521-01 1500A CM Line PG Outlet SV Automatic Valve PG Gas 2.00 kgf/cm2G 0.15 kgf/cm2G - 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
658 LG-A1502 DGA-11521-02 1500A VE-A1502 Level Level gauge CM Liquid - - - 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
22 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
660 PG-A1509 DGA-11521-02 1500A HE-A1501 CM Feed Press. Pressure gauge RG Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 80.0 deg C 60.0 deg C 2.2 kg/Nm3 0.014 cP
661 PG-A1510 DGA-11521-02 1500A HE-A1501 CM Press. Pressure gauge RG Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 40.0 deg C 2.0 kg/Nm3 0.013 cP
662 PG-A1511 DGA-11521-02 1500A HE-A1501 CM Outlet Press. Pressure gauge RG Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 40.0 deg C 2.0 kg/Nm3 0.013 cP
663 PG-A1512 DGA-11521-02 1500A HE-A1502 CM Press. Pressure gauge RG Vapor 8750.17 Nm3/h 6730.9 Nm3/h 2019.27 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 36.0 deg C 2.0 kg/Nm3 0.013 cP
664 PG-A1513 DGA-11521-02 1500A HE-A1502 CM Outlet Press. Pressure gauge RG Vapor 8750.17 Nm3/h 6730.9 Nm3/h 2019.27 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 36.0 deg C 2.0 kg/Nm3 0.013 cP
665 PG-A1514 DGA-11521-02 1500A HE-A1503 CM Press. Pressure gauge RG Vapor 6844.11 Nm3/h 5264.7 Nm3/h 1579.41 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 12.0 deg C 1.7 kg/Nm3 0.013 cP
666 PG-A1515 DGA-11521-02 1500A HE-A1503 CM Outlet Press. Pressure gauge RG Vapor 6844.11 Nm3/h 5264.7 Nm3/h 1579.41 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 12.0 deg C 1.7 kg/Nm3 0.013 cP
667 PG-A1516 DGA-11521-02 1500A HE-A1504 CM Press. Pressure gauge RG Vapor 6504.81 Nm3/h 5003.7 Nm3/h 1501.11 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 5.0 deg C 1.6 kg/Nm3 0.013 cP
668 PG-A1517 DGA-11521-02 1500A HE-A1504 CM Outlet Press. Pressure gauge RG Vapor 6504.81 Nm3/h 5003.7 Nm3/h 1501.11 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 5.0 deg C 1.6 kg/Nm3 0.013 cP
669 PG-A1518 DGA-11521-02 1500A VE-A1502 Press. Pressure gauge CM Vapor - - - 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 24.3 deg C 1.6 kg/Nm3 0.013 cP
670 PG-A1519A DGA-11521-02 1500A PU-A1502/A Discharge Press. Pressure gauge CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.39 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
671 PG-A1519B DGA-11521-02 1500A PU-A1502/B Discharge Press. Pressure gauge CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.39 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
672 PI-A1502 DGA-11521-02 1500A HE-A1502 RG Outlet Press. Pressure transmitter RG Vapor 6504.81 Nm3/h 5003.7 Nm3/h 1501.11 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 33.0 deg C 1.6 kg/Nm3 0.014 cP
679 LG-B1501 DGA-11522-01 1500B VE-B1501 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
682 PdG-B1503 DGA-11522-01 1500B FL-B1501/A Differential Press. Differential press. Gauge
RG Gas 5169.255 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
683 PdG-B1504 DGA-11522-01 1500B FL-B1501/B Differential Press. Differential press. Gauge
RG Gas 5169.255 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
684 PdG-B1505 DGA-11522-01 1500B FL-B1501/C Differential Press. Differential press. Gauge
RG Gas 5169.255 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
685 PG-B1501 DGA-11522-01 1500B VE-B1501 Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 0.0 deg C 2.2 kg/Nm3 0.013 cP
686 PG-B1502A DGA-11522-01 1500B PU-B1501/A Discharge Press. Pressure gauge CM Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 9.00 kgf/cm2G 6.83 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
23 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
687 PG-B1502B DGA-11522-01 1500B PU-B1501/B Discharge Press. Pressure gauge CM Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 9.00 kgf/cm2G 6.83 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
688 PG-B1506 DGA-11522-01 1500B FL-B1501/A CM Outlet Press. Pressure gauge RG Vapor 5169.255 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
689 PG-B1507 DGA-11522-01 1500B FL-B1501/B CM Outlet Press. Pressure gauge RG Vapor 5169.255 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
690 PG-B1508 DGA-11522-01 1500B FL-B1501/C CM Outlet Press. Pressure gauge RG Vapor 5169.255 Nm3/h 3976.4 Nm3/h 1192.905 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
691 PIC-B1501 DGA-11522-01 1500B FL-B1501/A,B,C RG Feed Press. Pressure transmitter RG Gas 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 2.00 kgf/cm2G 0.15 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
UN-B1501/A,B,C CM Outlet
692 PIC-B1502 DGA-11522-01 1500B Pressure transmitter CM Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 80.0 deg C 60.0 deg C 2.2 kg/Nm3 0.014 cP
Press.
694 SV-B1501 DGA-11522-01 1500B CM Line PG Outlet SV Automatic Valve PG Gas 2.00 kgf/cm2G 0.15 kgf/cm2G - 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.013 cP
696 LG-B1502 DGA-11522-02 1500B VE-B1502 Level Level gauge CM Liquid - - - 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
698 PG-B1509 DGA-11522-02 1500B HE-B1501 CM Feed Press. Pressure gauge RG Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 80.0 deg C 60.0 deg C 2.2 kg/Nm3 0.014 cP
699 PG-B1510 DGA-11522-02 1500B HE-B1501 CM Press. Pressure gauge RG Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 40.0 deg C 2.0 kg/Nm3 0.013 cP
700 PG-B1511 DGA-11522-02 1500B HE-B1501 CM Outlet Press. Pressure gauge RG Vapor 10338.51 Nm3/h 7952.7 Nm3/h 2385.81 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 40.0 deg C 2.0 kg/Nm3 0.013 cP
701 PG-B1512 DGA-11522-02 1500B HE-B1502 CM Press. Pressure gauge RG Vapor 8750.17 Nm3/h 6730.9 Nm3/h 2019.27 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 36.0 deg C 2.0 kg/Nm3 0.013 cP
702 PG-B1513 DGA-11522-02 1500B HE-B1502 CM Outlet Press. Pressure gauge RG Vapor 8750.17 Nm3/h 6730.9 Nm3/h 2019.27 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 36.0 deg C 2.0 kg/Nm3 0.013 cP
703 PG-B1514 DGA-11522-02 1500B HE-B1503 CM Press. Pressure gauge RG Vapor 6844.11 Nm3/h 5264.7 Nm3/h 1579.41 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 12.0 deg C 1.7 kg/Nm3 0.013 cP
704 PG-B1515 DGA-11522-02 1500B HE-B1503 CM Outlet Press. Pressure gauge RG Vapor 6844.11 Nm3/h 5264.7 Nm3/h 1579.41 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 12.0 deg C 1.7 kg/Nm3 0.013 cP
705 PG-B1516 DGA-11522-02 1500B HE-B1504 CM Press. Pressure gauge RG Vapor 6504.81 Nm3/h 5003.7 Nm3/h 1501.11 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 5.0 deg C 1.6 kg/Nm3 0.013 cP
706 PG-B1517 DGA-11522-02 1500B HE-B1504 CM Outlet Press. Pressure gauge RG Vapor 6504.81 Nm3/h 5003.7 Nm3/h 1501.11 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 5.0 deg C 1.6 kg/Nm3 0.013 cP
707 PG-B1518 DGA-11522-02 1500B VE-B1502 Press. Pressure gauge CM Vapor - - - 6.00 kgf/cm2G 4.00 kgf/cm2G 60.0 deg C 24.3 deg C 1.6 kg/Nm3 0.013 cP
708 PG-B1519A DGA-11522-02 1500B PU-B1502/A Discharge Press. Pressure gauge CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.39 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
709 PG-B1519B DGA-11522-02 1500B PU-B1502/B Discharge Press. Pressure gauge CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.39 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
24 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
710 PI-B1502 DGA-11522-02 1500B HE-B1502 RG Outlet Press. Pressure transmitter RG Vapor 6504.81 Nm3/h 5003.7 Nm3/h 1501.11 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 33.0 deg C 1.6 kg/Nm3 0.014 cP
717 FG-1601 DGA-11620-01 1600 C4 Line C4 Feed Flow Area Flowmeter C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 90.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
718 FG-1602 DGA-11620-01 1600 CL-1601 CM Feed Flow Area Flowmeter C4 Liquid 4264 kg/h 3280.0 kg/h 984 kg/h 6.00 kgf/cm2G 3.00 kgf/cm2G 80.0 deg C 68.0 deg C 1480.0 kg/m3 0.55 cP
719 FG-1603 DGA-11620-01 1600 CL-1601 CM Feed Flow Area Flowmeter C4 Liquid 61.1 kg/h 47.0 kg/h 14.1 kg/h 2.00 kgf/cm2G 0.50 kgf/cm2G 85.0 deg C 30.0 deg C 1520.0 kg/m3 0.81 cP
720 FI-1603 DGA-11620-01 1600 CL-1601 CM Feed Flow Flowmeter CM Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 11.00 kgf/cm2G 7.59 kgf/cm2G -15.0 deg C -10.0 deg C 1600.0 kg/m3 1 cP
721 FI-1604 DGA-11620-01 1600 HE-1606 C1 Outlet Flow Flowmeter C1 Vapor 0.364 kmol/h 0.3 kmol/h 0.084 kmol/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 30.0 deg C 5.7 kg/m3 0.011 cP
722 FIC-1605 DGA-11620-01 1600 HE-1605 S2 Feed Flow Flowmeter S2 Vapor 50.7 kg/h 39.0 kg/h 11.7 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
723 FIC-1605V DGA-11620-01 1600 HE-1605 S2 Feed Control Valve Control Valve S2 Vapor 50.7 kg/h 39.0 kg/h 11.7 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 0.1 kg/cm2 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
724 FIC-A1601 DGA-11620-01 1600 CL-1601 PG Feed Flow Flowmeter PG Gas 94.9 Nm3/h 73.0 Nm3/h 21.9 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G -15.0 deg C -10.0 deg C 11.8 kg/m3 0.012 cP
725 FIC-A1601V DGA-11620-01 1600 CL-1601 PG Feed Control Valve Control Valve PG Gas 94.9 Nm3/h 73.0 Nm3/h 21.9 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 0.05 kg/cm2 -15.0 deg C -10.0 deg C 11.8 kg/m3 0.012 cP
726 FIC-B1601 DGA-11620-01 1600 CL-1601 PG Feed Flow Flowmeter PG Gas 94.9 Nm3/h 73.0 Nm3/h 21.9 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G -15.0 deg C -10.0 deg C 11.8 kg/m3 0.012 cP
727 FIC-B1601V DGA-11620-01 1600 CL-1601 PG Feed Control Valve Control Valve PG Gas 94.9 Nm3/h 73.0 Nm3/h 21.9 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G 0.05 kg/cm2 -15.0 deg C -10.0 deg C 11.8 kg/m3 0.012 cP
728 LG-1601 DGA-11620-01 1600 CL-1601 Btm Level Level gauge CM Liquid - - - 6.00 kgf/cm2G 3.50 kgf/cm2G -20.0 deg C -10.0 deg C 1630.0 kg/m3 1.6 cP
729 LG-1602 DGA-11620-01 1600 CL-1602 Btm Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.60 kgf/cm2G 110.0 deg C 90.0 deg C 1450.0 kg/m3 0.43 cP
731 LIC-1601V DGA-11620-01 1600 HE-1602 CM Feed Control Valve Control Valve CM Liquid 4264 kg/h 3280.0 kg/h 984 kg/h 6.00 kgf/cm2G 3.50 kgf/cm2G 0.5 kg/cm2 -20.0 deg C -10.0 deg C 1630.0 kg/m3 1.6 cP
733 PG-1603 DGA-11620-01 1600 CL-1601 Btm Press. Pressure gauge PG Gas - - - 6.00 kgf/cm2G 3.50 kgf/cm2G -20.0 deg C -10.0 deg C 8.4 kg/m3 0.01 cP
734 PG-1604A DGA-11620-01 1600 PU-1601/A Discharge Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 11.00 kgf/cm2G 7.59 kgf/cm2G 60.0 deg C 17.0 deg C 1580.0 kg/m3 1 cP
735 PG-1604B DGA-11620-01 1600 PU-1601/B Discharge Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 11.00 kgf/cm2G 7.59 kgf/cm2G 60.0 deg C 17.0 deg C 1580.0 kg/m3 1 cP
736 PG-1605 DGA-11620-01 1600 CL-1602 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.60 kgf/cm2G 110.0 deg C 90.0 deg C 7.7 kg/m3 0.012 cP
737 PG-1606 DGA-11620-01 1600 HE-1605 S2 Feed Press. Pressure gauge S2 Vapor 50.7 kg/h 39.0 kg/h 11.7 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
25 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
738 PG-1607 DGA-11620-01 1600 HE-1606 C1 Outlet Press. Pressure gauge C1 Vapor 0.364 kmol/h 0.3 kmol/h 0.084 kmol/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 30.0 deg C 5.7 kg/m3 0.011 cP
739 PG-A1601 DGA-11620-01 1600 CL-1601 PG Feed Press. Pressure gauge PG Gas 94.9 Nm3/h 73.0 Nm3/h 21.9 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G -15.0 deg C -10.0 deg C 11.8 kg/m3 0.012 cP
740 PG-B1601 DGA-11620-01 1600 CL-1601 PG Feed Press. Pressure gauge PG Gas 94.9 Nm3/h 73.0 Nm3/h 21.9 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G -15.0 deg C -10.0 deg C 11.8 kg/m3 0.012 cP
741 PI-1601 DGA-11620-01 1600 CL-1601 PG Feed Press. Pressure transmitter PG Gas 189.8 Nm3/h 146.0 Nm3/h 43.8 Nm3/h 6.00 kgf/cm2G 4.00 kgf/cm2G -15.0 deg C -10.0 deg C 11.8 kg/m3 0.012 cP
742 PI-1602 DGA-11620-01 1600 CL-1601 PG Outlet Press. Pressure transmitter PG Gas 189.8 Nm3/h 146.0 Nm3/h 43.8 Nm3/h 6.00 kgf/cm2G 3.50 kgf/cm2G -20.0 deg C -10.0 deg C 8.4 kg/m3 0.01 cP
743 PI-1603 DGA-11620-01 1600 CL-1602 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.60 kgf/cm2G 110.0 deg C 90.0 deg C 7.7 kg/m3 0.012 cP
744 PI-1604 DGA-11620-01 1600 HE-1606 CM Feed Press. Pressure transmitter CM Vapor 222.3 kg/h 171.0 kg/h 51.3 kg/h 2.00 kgf/cm2G 0.60 kgf/cm2G 110.0 deg C 90.0 deg C 7.7 kg/m3 0.012 cP
745 SV-1601 DGA-11620-01 1600 C4 Line C4 Feed SV Automatic Valve C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G - 90.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
746 SV-A1602 DGA-11620-01 1600 VE-A1301 C1 Feed SV Automatic Valve C1 Vapor 0.364 kmol/h 0.3 kmol/h 0.084 kmol/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 30.0 deg C 5.7 kg/m3 0.011 cP
747 SV-B1602 DGA-11620-01 1600 VE-B1301 C1 Feed SV Automatic Valve C1 Vapor 0.364 kmol/h 0.3 kmol/h 0.084 kmol/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 30.0 deg C 5.7 kg/m3 0.011 cP
760 FI-1607 DGA-11620-02 1600 MT Line Flow Flowmeter MT Gas 268.97 Nm3/h 206.9 Nm3/h 62.07 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
761 PG-1608 DGA-11620-02 1600 CL-1603A TOP Press. Pressure gauge MT/PG Gas - - - 6.00 kgf/cm2G 2.00 kgf/cm2G 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
762 PG-1609 DGA-11620-02 1600 CL-1603B TOP Press. Pressure gauge MT/PG Gas - - - 6.00 kgf/cm2G 2.00 kgf/cm2G 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
763 PG-1610 DGA-11620-02 1600 CL-1603A S4 Feed Press. Pressure gauge S4 Vapor 322.4 kg/h 248.0 kg/h 74.4 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
764 PG-1611 DGA-11620-02 1600 CL-1603B S4 Feed Press. Pressure gauge S4 Vapor 322.4 kg/h 248.0 kg/h 74.4 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
765 PG-1612 DGA-11620-02 1600 HE-1609 S4 Feed Press. Pressure gauge S4 Vapor 44.2 kg/h 34.0 kg/h 10.2 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
766 PG-1613 DGA-11620-02 1600 MT Line Press. Pressure gauge MT Gas 268.97 Nm3/h 206.9 Nm3/h 62.07 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
767 PG-1614 DGA-11620-02 1600 MT Line Press. Pressure gauge MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
768 PIC-1605 DGA-11620-02 1600 MT Line Press. Pressure transmitter MT Gas 268.97 Nm3/h 206.9 Nm3/h 62.07 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
769 PIC-1605V DGA-11620-02 1600 MT Line Control Valve Control Valve MT Gas 268.97 Nm3/h 206.9 Nm3/h 62.07 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G 0.05 kg/cm2 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
770 PIC-1606 DGA-11620-02 1600 AR-1601 PG Feed Press. Pressure transmitter PG Gas 189.8 Nm3/h 146.0 Nm3/h 43.8 Nm3/h 6.00 kgf/cm2G 60.0 deg C 30.0 deg C 8.4 kg/m3 0.01 cP
771 PIC-1606V DGA-11620-02 1600 AR-1601 PG Feed Control Valve Control Valve PG Gas 189.8 Nm3/h 146.0 Nm3/h 43.8 Nm3/h 6.00 kgf/cm2G 1.10 kgf/cm2G 1.1 kg/cm2 60.0 deg C 30.0 deg C 8.4 kg/m3 0.01 cP
26 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
772 PIC-1607 DGA-11620-02 1600 AR-1602 PG Outlet Press. Pressure transmitter PG Gas 189.8 Nm3/h 146.0 Nm3/h 43.8 Nm3/h 6.00 kgf/cm2G 2.20 kgf/cm2G 60.0 deg C 30.0 deg C 8.4 kg/m3 0.01 cP
774 SV-1603 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
775 SV-1604 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
776 SV-1605 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
777 SV-1606 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
778 SV-1607 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
779 SV-1608 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
780 SV-1609 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
781 SV-1610 DGA-11620-02 1600 CL-1603A S4 Feed SV Automatic Valve S4 Vapor 322.4 kg/h 248.0 kg/h 74.4 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
782 SV-1611 DGA-11620-02 1600 CL-1603A CW Feed SV Automatic Valve CW Liquid 2.86 m3/h 2.2 m3/h 0.66 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 170.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
783 SV-1612 DGA-11620-02 1600 CL-1603A RCW Outlet SV Automatic Valve RCW Liquid 2.86 m3/h 2.2 m3/h 0.66 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 170.0 deg C 40.0 deg C 994.0 kg/m3 0.73 cP
784 SV-1614 DGA-11620-02 1600 CL-1603A SC Outlet SV Automatic Valve SC Liquid 322.4 kg/h 248.0 kg/h 74.4 kg/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 170.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
785 SV-1615 DGA-11620-02 1600 CL-1603B S4 Feed SV Automatic Valve S4 Vapor 322.4 kg/h 248.0 kg/h 74.4 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
786 SV-1616 DGA-11620-02 1600 CL-1603B CW Feed SV Automatic Valve CW Liquid 2.86 m3/h 2.2 m3/h 0.66 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 170.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
787 SV-1617 DGA-11620-02 1600 CL-1603B RCW Outlet SV Automatic Valve RCW Liquid 2.86 m3/h 2.2 m3/h 0.66 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 170.0 deg C 40.0 deg C 994.0 kg/m3 0.73 cP
788 SV-1619 DGA-11620-02 1600 CL-1603B SC Outlet SV Automatic Valve SC Liquid 322.4 kg/h 248.0 kg/h 74.4 kg/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 170.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
789 SV-1620 DGA-11620-02 1600 HE-1610 MT Outlet SV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
790 SV-1621 DGA-11620-02 1600 HE-1610 MT Outlet SV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
791 SV-1622 DGA-11620-02 1600 MT Line SV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
792 SV-1623 DGA-11620-02 1600 HE-1609/1607 MT Feed SV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
793 SV-1624 DGA-11620-02 1600 HE-1609 MT Feed SV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
27 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
794 SV-1625 DGA-11620-02 1600 HE-1607 MT Feed SV Automatic Valve MT Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 40.0 deg C 0.7 kg/Nm3 0.012 cP
795 SV-1626 DGA-11620-02 1600 AR-1601 PG Line S4 Feed SV Automatic Valve S4 Vapor 807.3 kg/h 621.0 kg/h 186.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
796 SV-1627 DGA-11620-02 1600 AR-1601 PG Line N3 Feed SV Automatic Valve N3 Gas 109.2 Nm3/h 84.0 Nm3/h 25.2 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
797 SV-1628 DGA-11620-02 1600 MT/PG Line SV Automatic Valve MT/PG Gas 128.57 Nm3/h 98.9 Nm3/h 29.67 Nm3/h 6.00 kgf/cm2G 2.00 kgf/cm2G - 140.0 deg C -10/120 deg C
0.7 kg/Nm3 0.012 cP
820 FG-1702 DGA-11720-01 1700 CM Line PW Feed Flow Area Flowmeter PW Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
821 FG-1706 DGA-11720-01 1700 CM Line PW Feed Flow Area Flowmeter PW Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
822 FG-1711 DGA-11720-01 1700 CL-1711 CS Feed Flow Area Flowmeter CS Liquid 0.13 m3/h 0.1 m3/h 0.03 m3/h 5.00 kgf/cm2G 3.93 kgf/cm2G 60.0 deg C 30.8 deg C 1193.0 kg/m3 1.649 cP
823 FG-1712 DGA-11720-01 1700 CL-1711 PW Feed Flow Area Flowmeter PW Liquid 0.13 m3/h 0.1 m3/h 0.03 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
824 FG-1713 DGA-11720-01 1700 CL-1711 CS Feed Flow Area Flowmeter CS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 5.00 kgf/cm2G 3.19 kgf/cm2G 60.0 deg C 40.0 deg C 1090.0 kg/m3 0.881 cP
825 FI-1702 DGA-11720-01 1700 CL-1701 CM Outlet Flow Flowmeter CM Liquid 13 m3/h 10.0 m3/h 3 m3/h 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 1030.0 kg/m3 0.721 cP
826 FIC-1701 DGA-11720-01 1700 PU-1701/A,B CM Feed Flow Flowmeter CM Liquid 12.87 m3/h 9.9 m3/h 2.97 m3/h 0.03 kgf/cm2G 0.03 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
828 LG-1701 DGA-11720-01 1700 TK-1701 Level Level gauge CM Liquid - - - 0.03 kgf/cm2G 0.03 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
829 LG-1702 DGA-11720-01 1700 CL-1701 Level Level gauge CM Liquid - - - 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 1078.0 kg/m3 0.791 cP
830 LG-1703 DGA-11720-01 1700 CL-1701 Level Level gauge CM Liquid - - - 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
831 LG-1704 DGA-11720-01 1700 CL-1702 Level Level gauge CM Liquid - - - 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 992.0 kg/m3 0.599 cP
832 LG-1705 DGA-11720-01 1700 CL-1702 Level Level gauge CM Liquid - - - 0.10 kgf/cm2G 0.10 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
833 LG-1706 DGA-11720-01 1700 TK-1704 Level Level gauge CM Liquid - - - 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 1023.0 kg/m3 0.669 cP
834 LG-1707 DGA-11720-01 1700 TK-1704 Level Level gauge CM Liquid - - - 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 1023.0 kg/m3 0.669 cP
835 LG-1711 DGA-11720-01 1700 CL-1711 Level Level gauge CS Liquid - - - 0.10 kgf/cm2G 0.10 kgf/cm2G 60.0 deg C 40.0 deg C 1090.0 kg/m3 0.881 cP
836 LI-1701 DGA-11720-01 1700 TK-1701 Level Radar Level meter CM Liquid - - - 0.03 kgf/cm2G 0.03 kgf/cm2G 60.0 deg C 40.0 deg C 1344.0 kg/m3 0.384 cP
28 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
839 PG-1701A DGA-11720-01 1700 PU-1701/A Discharge Press. Pressure gauge CM Liquid 27.95 m3/h 21.5 m3/h 6.45 m3/h 4.00 kgf/cm2G 2.56 kgf/cm2G 60.0 deg C 40.0 deg C 1105.0 kg/m3 0.591 cP
840 PG-1701B DGA-11720-01 1700 PU-1701/B Discharge Press. Pressure gauge CM Liquid 27.95 m3/h 21.5 m3/h 6.45 m3/h 4.00 kgf/cm2G 2.56 kgf/cm2G 60.0 deg C 40.0 deg C 1105.0 kg/m3 0.591 cP
841 PG-1702A DGA-11720-01 1700 PU-1704/A Discharge Press. Pressure gauge CM Liquid 31.85 m3/h 24.5 m3/h 7.35 m3/h 4.00 kgf/cm2G 2.68 kgf/cm2G 60.0 deg C 40.0 deg C 1186.0 kg/m3 0.529 cP
842 PG-1702B DGA-11720-01 1700 PU-1704/B Discharge Press. Pressure gauge CM Liquid 31.85 m3/h 24.5 m3/h 7.35 m3/h 4.00 kgf/cm2G 2.68 kgf/cm2G 60.0 deg C 40.0 deg C 1186.0 kg/m3 0.529 cP
843 PG-1711 DGA-11720-01 1700 CL-1711 Press. Pressure gauge CS Vapor - - - 0.10 kgf/cm2G 0.10 kgf/cm2G 60.0 deg C 40.0 deg C 1.3 kg/Nm3 0.018 cP
844 PG-1712A DGA-11720-01 1700 PU-1711/A Discharge Press. Pressure gauge CS Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.19 kgf/cm2G 60.0 deg C 40.0 deg C 1090.0 kg/m3 0.881 cP
845 PG-1712B DGA-11720-01 1700 PU-1711/B Discharge Press. Pressure gauge CS Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 5.00 kgf/cm2G 3.19 kgf/cm2G 60.0 deg C 40.0 deg C 1090.0 kg/m3 0.881 cP
846 QI-1701 DGA-11720-01 1700 CL-1701 CM Outlet Density Densitometer CM Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 1078.0 kg/m3 0.791 cP
847 QI-1702 DGA-11720-01 1700 CL-1702 CM Outlet Density Densitometer CM Liquid 0.39 m3/h 0.3 m3/h 0.09 m3/h 0.10 kgf/cm2G 0.05 kgf/cm2G 60.0 deg C 40.0 deg C 992.0 kg/m3 0.599 cP
850 FI-1703 DGA-11720-02 1700 VE-1701CM Outlet Flow Flowmeter CM Liquid 5.72 m3/h 4.4 m3/h 1.32 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 49.0 deg C 1268.0 kg/m3 0.336 cP
851 FIC-1704 DGA-11720-02 1700 CL-1703 CM Feed Flow Flowmeter CM Liquid 18.33 m3/h 14.1 m3/h 4.23 m3/h 6.00 kgf/cm2G 4.20 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
852 FIC-1704V DGA-11720-02 1700 CL-1703 CM Feed Control Valve Control Valve CM Liquid 18.33 m3/h 14.1 m3/h 4.23 m3/h 6.00 kgf/cm2G 4.20 kgf/cm2G 0.5 kg/cm2 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
853 FIC-1705 DGA-11720-02 1700 HE-1701 S2 Feed Flow Flowmeter S2 Vapor 1376.7 kg/h 1059.0 kg/h 317.7 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
854 FIC-1705V DGA-11720-02 1700 HE-1701 S2 Feed Control Valve Control Valve S2 Vapor 1376.7 kg/h 1059.0 kg/h 317.7 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 0.1 kg/cm2 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
855 LG-1708 DGA-11720-02 1700 TK-1702 Level Level gauge CM Liquid - - - 0.10 kgf/cm2G 0.03 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
856 LG-1709 DGA-11720-02 1700 CL-1703 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 3.7 kg/Nm3 0.011 cP
857 LG-1710 DGA-11720-02 1700 TK-1703 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
858 LI-1702 DGA-11720-02 1700 TK-1702 Level Radar Level meter CM Liquid - - - 0.10 kgf/cm2G 0.03 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
859 LI-1704 DGA-11720-02 1700 TK-1703 Level Radar Level meter CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
860 LIC-1703 DGA-11720-02 1700 CL-1703 Level Radar Level meter CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 3.7 kg/Nm3 0.011 cP
29 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
862 PG-1703A DGA-11720-02 1700 PU-1702/A Discharge Press. Pressure gauge CM Liquid 18.33 m3/h 14.1 m3/h 4.23 m3/h 6.00 kgf/cm2G 4.20 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
863 PG-1703B DGA-11720-02 1700 PU-1702/B Discharge Press. Pressure gauge CM Liquid 18.33 m3/h 14.1 m3/h 4.23 m3/h 6.00 kgf/cm2G 4.20 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
864 PG-1704 DGA-11720-02 1700 CL-1703 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 3.7 kg/Nm3 0.011 cP
865 PG-1705 DGA-11720-02 1700 HE-1701 S2 Feed Press. Pressure gauge S2 Vapor 1376.7 kg/h 1059.0 kg/h 317.7 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
866 PG-1706A DGA-11720-02 1700 PU-1703/A Discharge Press. Pressure gauge CM Liquid 13.26 m3/h 10.2 m3/h 3.06 m3/h 8.00 kgf/cm2G 5.70 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
867 PG-1706B DGA-11720-02 1700 PU-1703/B Discharge Press. Pressure gauge CM Liquid 13.26 m3/h 10.2 m3/h 3.06 m3/h 8.00 kgf/cm2G 5.70 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
868 PI-1702 DGA-11720-02 1700 CL-1703 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 3.7 kg/Nm3 0.011 cP
869 PIC-1701 DGA-11720-02 1700 HE-1702/1,2 CM Feed Press. Pressure transmitter CM Vapor 1951.82 Nm3/h 1501.4 Nm3/h 450.42 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 49.0 deg C 3.7 kg/Nm3 0.011 cP
874 EV-1701 DGA-11720-03 1700 TK-1705 CM Outlet EV Automatic Valve CM Liquid m3/h m3/h m3/h kgf/cm2G kgf/cm2G - deg C deg C kg/m3 cP
875 FG-1705 DGA-11720-03 1700 TK-1705 CM DIscharge Flow Area Flowmeter CM Liquid 18.33 m3/h 14.1 m3/h 4.23 m3/h 6.00 kgf/cm2G 4.20 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
876 LG-1712 DGA-11720-03 1700 TK-1705 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
877 LI-1705 DGA-11720-03 1700 TK-1705 Level Radar Level meter CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
878 PG-1713A DGA-11720-03 1700 PU-1705/A Discharge Press. Pressure gauge CM Liquid 18.33 m3/h 14.1 m3/h 4.23 m3/h 6.00 kgf/cm2G 4.20 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
879 PG-1713B DGA-11720-03 1700 PU-1705/B Discharge Press. Pressure gauge CM Liquid 18.33 m3/h 14.1 m3/h 4.23 m3/h 6.00 kgf/cm2G 4.20 kgf/cm2G 60.0 deg C 40.0 deg C 1327.0 kg/m3 0.376 cP
880 PI-1703 DGA-11720-03 1700 TK-1705 Press. Pressure transmitter CM Vapor - - - 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 2.3 kg/Nm3 0.014 cP
882 EV-A1811 DGA-11821-01 1800A HE-A1813 CM Feed EV Automatic Valve CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.40 kgf/cm2G - 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
883 EV-A1812 DGA-11821-01 1800A CL-A1811 CM Outlet EV Automatic Valve CM Liquid 7.02 m3/h 5.4 m3/h 1.62 m3/h 10.00 kgf/cm2G 8.30 kgf/cm2G - 140.0 deg C 123.0 deg C 1160.0 kg/m3 0.214 cP
884 FG-A1801 DGA-11821-01 1800A HE-A1801 C2 Outlet Flow Area Flowmeter C2 Liquid 0.013 m3/h 0.0 m3/h 0.003 m3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
885 FI-A1802 DGA-11821-01 1800A HE-A1801 C1 Outlet Flow Flowmeter C1 Gas 1884.22 Nm3/h 1449.4 Nm3/h 434.82 Nm3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 2.3 kg/Nm3 0.01 cP
30 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
886 FI-A1813 DGA-11821-01 1800A CL-A1811 C1 Feed Flow Flowmeter C1 Liquid 4.81 m3/h 3.7 m3/h 1.11 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 880.0 kg/m3 0.149 cP
887 FIC-A1801 DGA-11821-01 1800A HE-A1801 C1 Feed Flow Flowmeter C1 Liquid 0 m3/h 0.0 m3/h 0 m3/h 14.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 874.0 kg/m3 0.144 cP
889 FIC-A1811 DGA-11821-01 1800A HE-A1813 CM Feed Flow Flowmeter CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.40 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
891 FIC-A1812 DGA-11821-01 1800A HE-A1811 S4 Feed Flow Flowmeter S4 Vapor 1820 kg/h 1400.0 kg/h 420 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
893 FIC-A1814 DGA-11821-01 1800A HE-A1801 C1 Feed Flow Flowmeter C1 Liquid 4.81 m3/h 3.7 m3/h 1.11 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 880.0 kg/m3 0.149 cP
895 FIC-A1815 DGA-11821-01 1800A HE-A1814 CM Outlet Flow Flowmeter CM Liquid 6.11 m3/h 4.7 m3/h 1.41 m3/h 10.00 kgf/cm2G 8.30 kgf/cm2G 60.0 deg C 40.0 deg C 1336.0 kg/m3 0.378 cP
897 LG-A1801 DGA-11821-01 1800A HE-A1801 C2 Level Level gauge C2 Liquid - - - 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
898 LG-A1811 DGA-11821-01 1800A CL-A1811 Level Level gauge CM Liquid - - - 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 1160.0 kg/m3 0.214 cP
902 PG-A1801 DGA-11821-01 1800A HE-A1801 C1 Press. Pressure gauge C1 Gas - - - 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 2.3 kg/Nm3 0.01 cP
903 PG-A1811 DGA-11821-01 1800A CL-A1811 Btm Press. Pressure gauge CM Vapor - - - 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 2.3 kg/Nm3 0.014 cP
904 PG-A1812 DGA-11821-01 1800A HE-A1811 S4 Feed Press. Pressure gauge S4 Vapor 1820 kg/h 1400.0 kg/h 420 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
HE-A1812/1,2 C1 Discharge
905 PG-A1813 DGA-11821-01 1800A Pressure gauge C1 Gas 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 2.3 kg/Nm3 0.014 cP
Press.
906 PI-A1811 DGA-11821-01 1800A CL-A1811 Btm Press. Pressure transmitter CM Vapor - - - 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 2.3 kg/Nm3 0.014 cP
907 PI-A1812 DGA-11821-01 1800A CL-A1811 C1 Outlet Press. Pressure transmitter C1 Gas 3762.72 Nm3/h 2894.4 Nm3/h 868.32 Nm3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 2.3 kg/Nm3 0.014 cP
31 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
HE-A1812/1,2 C1 Discharge
908 PIC-A1813 DGA-11821-01 1800A Pressure transmitter C1 Gas 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 2.3 kg/Nm3 0.014 cP
Press.
919 EV-A1821 DGA-11821-02 1800A HE-A1826 C2 Outlet EV Automatic Valve C2 Liquid 4.29 m3/h 3.3 m3/h 0.99 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1335.0 kg/m3 0.447 cP
920 FG-A1821 DGA-11821-02 1800A HE-A1825 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
921 FI-A1824 DGA-11821-02 1800A CL-A1821 C2 Feed Flow Flowmeter C2 Liquid 0.52 m3/h 0.4 m3/h 0.12 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
922 FIC-A1821 DGA-11821-02 1800A CL-A1821 CM Feed Flow Flowmeter CM Liquid 6.63 m3/h 5.1 m3/h 1.53 m3/h 8.00 kgf/cm2G 5.70 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
924 FIC-A1822 DGA-11821-02 1800A CL-A1821 CM Feed Flow Flowmeter CM Liquid 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 1160.0 kg/m3 0.214 cP
926 FIC-A1823 DGA-11821-02 1800A HE-A1821 S2 Feed Flow Flowmeter S2 Vapor 85.8 kg/h 66.0 kg/h 19.8 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
PU-A1821/A,B C2 Discharge
928 FIC-A1825 DGA-11821-02 1800A Flowmeter C2 Liquid 130 L/h 100.0 L/h 30 L/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
Flow
PU-A1821/A,B C2 Discharge
929 FIC-A1825V DGA-11821-02 1800A Control Valve C2 Liquid 0.13 m3/h 0.1 m3/h 0.03 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 0.5 kg/cm2 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
Control Valve
930 FIC-A1826 DGA-11821-02 1800A CL-A1822 CM Feed Flow Flowmeter CM Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 7.00 kgf/cm2G 5.07 kgf/cm2G 80.0 deg C 62.0 deg C 1307.0 kg/m3 0.321 cP
932 FIC-A1827 DGA-11821-02 1800A HE-A1823 S2 Feed Flow Flowmeter S2 Vapor 4082 kg/h 3140.0 kg/h 942 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
934 FIC-A1828 DGA-11821-02 1800A CL-A1831 CM Feed Flow Flowmeter CM Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 8.00 kgf/cm2G 5.42 kgf/cm2G 100.0 deg C 81.0 deg C 1386.0 kg/m3 0.339 cP
936 FIC-A1829 DGA-11821-02 1800A HE-A1826 C2 Outlet Flow Flowmeter C2 Liquid 4.29 m3/h 3.3 m3/h 0.99 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 15.0 deg C 1335.0 kg/m3 0.447 cP
32 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
938 FIC-A1830 DGA-11821-02 1800A CL-A1822 C2 Feed Flow Flowmeter C2 Liquid 17.94 m3/h 13.8 m3/h 4.14 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
940 FIC-A1831 DGA-11821-02 1800A PU-A1823/A,B C2 Outlet Flow Flowmeter C2 Liquid 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
PU-A1823/A,B C2 Outlet
941 FIC-A1831V DGA-11821-02 1800A Control Valve C2 Liquid 8.00 kgf/cm2G 6.04 kgf/cm2G 0.5 kg/cm2 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
Control Valve
942 LG-A1821 DGA-11821-02 1800A CL-A1821 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 80.0 deg C 62.0 deg C 1306.0 kg/m3 0.321 cP
943 LG-A1822 DGA-11821-02 1800A TK-A1821 Level Level gauge C2 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
944 LG-A1823 DGA-11821-02 1800A CL-A1822 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 100.0 deg C 81.0 deg C 1385.0 kg/m3 0.339 cP
945 LG-A1824 DGA-11821-02 1800A TK-A1822 Level Level gauge C2 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
951 PG-A1821 DGA-11821-02 1800A CL-A1821 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 80.0 deg C 62.0 deg C 3.8 kg/Nm3 0.011 cP
952 PG-A1822 DGA-11821-02 1800A HE-A1821 S2 Feed Press. Pressure gauge S2 Vapor 85.8 kg/h 66.0 kg/h 19.8 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
953 PG-A1823A DGA-11821-02 1800A PU-A1821/A Discharge Press. Pressure gauge C2 Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
954 PG-A1823B DGA-11821-02 1800A PU-A1821/B Discharge Press. Pressure gauge C2 Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
955 PG-A1824A DGA-11821-02 1800A PU-A1822/A Discharge Press. Pressure gauge CM Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 7.00 kgf/cm2G 5.07 kgf/cm2G 80.0 deg C 62.0 deg C 1307.0 kg/m3 0.321 cP
956 PG-A1824B DGA-11821-02 1800A PU-A1822/B Discharge Press. Pressure gauge CM Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 7.00 kgf/cm2G 5.07 kgf/cm2G 80.0 deg C 62.0 deg C 1307.0 kg/m3 0.321 cP
957 PG-A1825 DGA-11821-02 1800A CL-A1822 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 100.0 deg C 81.0 deg C 3.8 kg/Nm3 0.011 cP
958 PG-A1826 DGA-11821-02 1800A HE-A1823 S2 Feed Press. Pressure gauge S2 Vapor 4082 kg/h 3140.0 kg/h 942 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
959 PG-A1827A DGA-11821-02 1800A PU-A1823/A Discharge Press. Pressure gauge C2 Liquid 17.94 m3/h 13.8 m3/h 4.14 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
33 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
960 PG-A1827B DGA-11821-02 1800A PU-A1823/B Discharge Press. Pressure gauge C2 Liquid 17.94 m3/h 13.8 m3/h 4.14 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
961 PG-A1828A DGA-11821-02 1800A PU-A1824/A Discharge Press. Pressure gauge CM Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 8.00 kgf/cm2G 5.42 kgf/cm2G 100.0 deg C 81.0 deg C 1386.0 kg/m3 0.339 cP
962 PG-A1828B DGA-11821-02 1800A PU-A1824/B Discharge Press. Pressure gauge CM Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 8.00 kgf/cm2G 5.42 kgf/cm2G 100.0 deg C 81.0 deg C 1386.0 kg/m3 0.339 cP
963 PG-A1829 DGA-11821-02 1800A HE-A1822 C2 Press. Pressure gauge C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
964 PG-A1830 DGA-11821-02 1800A HE-A1824/1,2 C2 Outlet Press. Pressure gauge C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
965 PI-A1821 DGA-11821-02 1800A CL-A1821 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 80.0 deg C 62.0 deg C 3.8 kg/Nm3 0.011 cP
966 PI-A1823 DGA-11821-02 1800A CL-A1822 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 100.0 deg C 81.0 deg C 3.8 kg/Nm3 0.011 cP
967 PI-A1824 DGA-11821-02 1800A CL-A1821 Top C2 Press. Pressure transmitter C2 Vapor 205.66 Nm3/h 158.2 Nm3/h 47.46 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
968 PI-A1826 DGA-11821-02 1800A HE-A1824/1,2 C2 Feed Press. Pressure transmitter C2 Vapor 5994.69 Nm3/h 4611.3 Nm3/h 1383.39 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
969 PIC-A1822 DGA-11821-02 1800A HE-A1822 C2 Press. Pressure transmitter C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
972 PIC-A1825 DGA-11821-02 1800A HE-A1824/1,2 C2 Outlet Press. Pressure transmitter C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
975 SV-A1821 DGA-11821-02 1800A HE-A1822 PW Feed SV Automatic Valve PW Liquid 0 m3/h 0.0 m3/h 0 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
976 SV-A1822 DGA-11821-02 1800A HE-A1824/1,2 PW Feed SV Automatic Valve PW Liquid 0 m3/h 0.0 m3/h 0 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
985 EV-A1831 DGA-11821-03 1800A HE-A1835 C3 Outlet EV Automatic Valve C3 Liquid 1.443 m3/h 1.1 m3/h 0.333 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1498.0 kg/m3 0.587 cP
986 FG-A1831 DGA-11821-03 1800A HE-A1833 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
987 FI-A1833 DGA-11821-03 1800A CL-A1831 C3 Feed Flow Flowmeter C3 Liquid 6.11 m3/h 4.7 m3/h 1.41 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
988 FIC-A1832 DGA-11821-03 1800A PU-A1832/A,B CM Outlet Flow Flowmeter CM Liquid 247 L/h 190.0 L/h 57 L/h 8.00 kgf/cm2G 5.49 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
PU-A1832/A,B CM Outlet
989 FIC-A1832V DGA-11821-03 1800A Control Valve CM Liquid 0.247 m3/h 0.2 m3/h 0.057 m3/h 8.00 kgf/cm2G 5.49 kgf/cm2G 0.5 kg/cm2 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
Control Valve
34 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
990 FIC-A1834 DGA-11821-03 1800A HE-A1836 C3 Outlet Flow Flowmeter C3 Liquid 0.442 m3/h 0.3 m3/h 0.102 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 60.0 deg C 40.0 deg C 1452.0 kg/m3 0.456 cP
992 FIC-A1835 DGA-11821-03 1800A HE-A1835 C3 Outlet Flow Flowmeter C3 Liquid 1.443 m3/h 1.1 m3/h 0.333 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 15.0 deg C 1498.0 kg/m3 0.587 cP
994 FIC-A1836 DGA-11821-03 1800A CL-A1832 C3 Feed Flow Flowmeter C3 Liquid 6.903 m3/h 5.3 m3/h 1.593 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
996 FIC-A1837 DGA-11821-03 1800A PU-A1831/A,B C3 Outlet Flow Flowmeter C3 Liquid 182 L/h 140.0 L/h 42 L/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
PU-A1831/A,B C3 Outlet
997 FIC-A1837V DGA-11821-03 1800A Control Valve C3 Liquid 0.182 m3/h 0.1 m3/h 0.042 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 0.5 kg/cm2 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
Control Valve
998 FIC-A1838 DGA-11821-03 1800A HE-A1831 S2 Feed Flow Flowmeter S2 Vapor 1384.5 kg/h 1065.0 kg/h 319.5 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1000 LG-A1831 DGA-11821-03 1800A CL-A1831 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
1001 LG-A1832 DGA-11821-03 1800A CL-A1832 Level Level gauge C3 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1002 LG-A1833 DGA-11821-03 1800A TK-A1831 Level Level gauge C3 Liquid - - - 2.00 kgf/cm2G 0.00 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1005 LIC-A1832 DGA-11821-03 1800A CL-A1832 Btm Level Differential press. Transmitter
C3 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1007 PG-A1831 DGA-11821-03 1800A CL-A1831 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 120.0 deg C 100.0 deg C 5.3 kg/Nm3 0.012 cP
1008 PG-A1832 DGA-11821-03 1800A HE-A1831 S2 Feed Press. Pressure gauge S2 Vapor 1384.5 kg/h 1065.0 kg/h 319.5 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1009 PG-A1833A DGA-11821-03 1800A PU-A1832/A Discharge Press. Pressure gauge CM Liquid 0.247 m3/h 0.2 m3/h 0.057 m3/h 8.00 kgf/cm2G 5.49 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
1010 PG-A1833B DGA-11821-03 1800A PU-A1832/B Discharge Press. Pressure gauge CM Liquid 0.247 m3/h 0.2 m3/h 0.057 m3/h 8.00 kgf/cm2G 5.49 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
1011 PG-A1834 DGA-11821-03 1800A CL-A1832 Btm Press. Pressure gauge C3 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 5.3 kg/Nm3 0.012 cP
35 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1012 PG-A1835A DGA-11821-03 1800A PU-A1833/A Discharge Press. Pressure gauge C3 Liquid 9.1 m3/h 7.0 m3/h 2.1 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1013 PG-A1835B DGA-11821-03 1800A PU-A1833/B Discharge Press. Pressure gauge C3 Liquid 9.1 m3/h 7.0 m3/h 2.1 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1014 PG-A1836A DGA-11821-03 1800A PU-A1831/A Discharge Press. Pressure gauge C3 Liquid 7.085 m3/h 5.5 m3/h 1.635 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1015 PG-A1836B DGA-11821-03 1800A PU-A1831/B Discharge Press. Pressure gauge C3 Liquid 7.085 m3/h 5.5 m3/h 1.635 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1016 PI-A1831 DGA-11821-03 1800A CL-A1831 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 120.0 deg C 100.0 deg C 5.3 kg/Nm3 0.012 cP
1017 PI-A1832 DGA-11821-03 1800A CL-A1832 C3 Feed Press. Pressure transmitter C3 Vapor 1877.72 Nm3/h 1444.4 Nm3/h 433.32 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 5.3 kg/Nm3 0.012 cP
1018 PI-A1833 DGA-11821-03 1800A CL-A1832 TOP C3 Press. Pressure transmitter C3 Vapor - - - 2.00 kgf/cm2G 0.00 kgf/cm2G 80.0 deg C 61.0 deg C 5.3 kg/Nm3 0.012 cP
1019 SV-A1831 DGA-11821-03 1800A HE-A1832 PW Feed SV Automatic Valve PW Liquid 149.11 m3/h 114.7 m3/h 34.41 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1031 EV-A1841 DGA-11821-04 1800A HE-A1845 C4 Outlet EV Automatic Valve C4 Liquid 0.182 m3/h 0.1 m3/h 0.042 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G - 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1034 FG-A1843 DGA-11821-04 1800A HE-A1844 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1035 FG-A1844 DGA-11821-04 1800A HE-A1843 HB Feed Flow Area Flowmeter HB Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 6.00 kgf/cm2G 4.03 kgf/cm2G 120.0 deg C 105.0 deg C 1488.0 kg/m3 0.495 cP
1036 FIC-A1841 DGA-11821-04 1800A CL-A1841 S2 Feed Flow Flowmeter S2 Vapor 70.2 kg/h 54.0 kg/h 16.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1038 FIC-A1842 DGA-11821-04 1800A CL-A1841 C4 Feed Flow Flowmeter C4 Liquid 325 L/h 250.0 L/h 75 L/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1040 FIC-A1843 DGA-11821-04 1800A PU-A1841/A,B C4 Outlet Flow Flowmeter C4 Liquid 52 L/h 40.0 L/h 12 L/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
PU-A1841/A,B C4 Outlet
1041 FIC-A1843V DGA-11821-04 1800A Control Valve C4 Liquid 0.052 m3/h 0.0 m3/h 0.012 m3/h 9.00 kgf/cm2G 6.20 kgf/cm2G 0.5 kg/cm2 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
Control Valve
1042 FIC-A1844 DGA-11821-04 1800A CL-A1842 C4 Feed Flow Flowmeter C4 Liquid 195 L/h 150.0 L/h 45 L/h 7.00 kgf/cm2G 5.09 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/m3 0.427 cP
1044 FIC-A1845 DGA-11821-04 1800A CL-A1842 S4 Feed Flow Flowmeter S4 Vapor 274.3 kg/h 211.0 kg/h 63.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
36 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1046 FIC-A1846 DGA-11821-04 1800A CL-A1842 C4 Feed Flow Flowmeter C4 Liquid 0.793 m3/h 0.6 m3/h 0.183 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
1048 FIC-A1847 DGA-11821-04 1800A PU-A1843/A,B C4 Outlet Flow Flowmeter C4 Liquid 182 L/h 140.0 L/h 42 L/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
PU-A1843/A,B C4 Outlet
1049 FIC-A1847V DGA-11821-04 1800A Control Valve C4 Liquid 0.182 m3/h 0.1 m3/h 0.042 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 3 kg/cm2 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
Control Valve
1050 LG-A1841 DGA-11821-04 1800A CL-A1841 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/Nm3 0.427 cP
1051 LG-A1842 DGA-11821-04 1800A TK-A1841 Level Level gauge C4 Liquid - - - 2.00 kgf/cm2G 0.10 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1052 LG-A1843 DGA-11821-04 1800A CL-A1842 Level Level gauge HB Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 105.0 deg C 1488.0 kg/m3 0.495 cP
1053 LG-A1844 DGA-11821-04 1800A TK-A1842 Level Level gauge C4 Liquid - - - 2.00 kgf/cm2G 0.10 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
1058 PG-A1841 DGA-11821-04 1800A CL-A1841 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 110.0 deg C 90.0 deg C 5.3 kg/Nm3 0.012 cP
1059 PG-A1842 DGA-11821-04 1800A CL-A1841 S2 Feed Press. Pressure gauge S2 Vapor 70.2 kg/h 54.0 kg/h 16.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1060 PG-A1843A DGA-11821-04 1800A PU-A1841/A Discharge Press. Pressure gauge C4 Liquid 0.377 m3/h 0.3 m3/h 0.087 m3/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1061 PG-A1843B DGA-11821-04 1800A PU-A1841/B Discharge Press. Pressure gauge C4 Liquid 0.377 m3/h 0.3 m3/h 0.087 m3/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1062 PG-A1844A DGA-11821-04 1800A PU-A1842/A Discharge Press. Pressure gauge C4 Liquid 0.195 m3/h 0.2 m3/h 0.045 m3/h 7.00 kgf/cm2G 5.09 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/m3 0.427 cP
1063 PG-A1844B DGA-11821-04 1800A PU-A1842/B Discharge Press. Pressure gauge C4 Liquid 0.195 m3/h 0.2 m3/h 0.045 m3/h 7.00 kgf/cm2G 5.09 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/m3 0.427 cP
1064 PG-A1845 DGA-11821-04 1800A CL-A1842 Btm Press. Pressure gauge C4 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 105.0 deg C 6.9 kg/Nm3 0.012 cP
1065 PG-A1846 DGA-11821-04 1800A CL-A1842 S4 Feed Press. Pressure gauge S4 Vapor 274.3 kg/h 211.0 kg/h 63.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1066 PG-A1847 DGA-11821-04 1800A PU-A1844 Discharge Press. Pressure gauge HB Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 6.00 kgf/cm2G 4.03 kgf/cm2G 120.0 deg C 105.0 deg C 1488.0 kg/m3 0.495 cP
37 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1067 PG-A1848A DGA-11821-04 1800A PU-A1843/A Discharge Press. Pressure gauge C4 Liquid 0.975 m3/h 0.8 m3/h 0.225 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
1068 PG-A1848B DGA-11821-04 1800A PU-A1843/B Discharge Press. Pressure gauge C4 Liquid 0.975 m3/h 0.8 m3/h 0.225 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
1069 PI-A1841 DGA-11821-04 1800A CL-A1841 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 110.0 deg C 90.0 deg C 5.3 kg/Nm3 0.012 cP
1070 PI-A1842 DGA-11821-04 1800A HE-A1841 C4 Feed Press. Pressure transmitter C4 Vapor 97.5 Nm3/h 75.0 Nm3/h 22.5 Nm3/h 2.00 kgf/cm2G 0.10 kgf/cm2G 80.0 deg C 61.0 deg C 5.3 kg/Nm3 0.012 cP
1071 PI-A1843 DGA-11821-04 1800A CL-A1842 Btm Press. Pressure transmitter C4 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 105.0 deg C 6.9 kg/Nm3 0.012 cP
1072 PI-A1844 DGA-11821-04 1800A HE-A1842 C4 Feed Press. Pressure transmitter C4 Vapor 212.03 Nm3/h 163.1 Nm3/h 48.93 Nm3/h 2.00 kgf/cm2G 0.10 kgf/cm2G 90.0 deg C 77.0 deg C 6.9 kg/Nm3 0.012 cP
1083 EV-B1811 DGA-11822-01 1800B HE-B1813 CM Feed EV Automatic Valve CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.40 kgf/cm2G - 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
1084 EV-B1812 DGA-11822-01 1800B CL-B1811 CM Outlet EV Automatic Valve CM Liquid 7.02 m3/h 5.4 m3/h 1.62 m3/h 10.00 kgf/cm2G 8.30 kgf/cm2G - 140.0 deg C 123.0 deg C 1160.0 kg/m3 0.214 cP
1085 FG-B1801 DGA-11822-01 1800B HE-B1801 C2 Outlet Flow Area Flowmeter C2 Liquid 0.013 m3/h 0.0 m3/h 0.003 m3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
1086 FI-B1802 DGA-11822-01 1800B HE-B1801 C1 Outlet Flow Flowmeter C1 Gas 1884.22 Nm3/h 1449.4 Nm3/h 434.82 Nm3/h 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 2.3 kg/Nm3 0.01 cP
1087 FI-B1813 DGA-11822-01 1800B CL-B1811 C1 Feed Flow Flowmeter C1 Liquid 4.81 m3/h 3.7 m3/h 1.11 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 880.0 kg/m3 0.149 cP
1088 FIC-B1801 DGA-11822-01 1800B HE-B1801 C1 Feed Flow Flowmeter C1 Liquid 0 m3/h 0.0 m3/h 0 m3/h 14.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 874.0 kg/m3 0.144 cP
1090 FIC-B1811 DGA-11822-01 1800B HE-B1813 CM Feed Flow Flowmeter CM Liquid 10.53 m3/h 8.1 m3/h 2.43 m3/h 17.00 kgf/cm2G 13.40 kgf/cm2G 60.0 deg C 24.3 deg C 1171.0 kg/m3 0.275 cP
1092 FIC-B1812 DGA-11822-01 1800B HE-B1811 S4 Feed Flow Flowmeter S4 Vapor 1820 kg/h 1400.0 kg/h 420 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1094 FIC-B1814 DGA-11822-01 1800B HE-B1801 C1 Feed Flow Flowmeter C1 Liquid 4.81 m3/h 3.7 m3/h 1.11 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 880.0 kg/m3 0.149 cP
1096 FIC-B1815 DGA-11822-01 1800B HE-B1814 CM Outlet Flow Flowmeter CM Liquid 6.11 m3/h 4.7 m3/h 1.41 m3/h 10.00 kgf/cm2G 8.30 kgf/cm2G 60.0 deg C 40.0 deg C 1336.0 kg/m3 0.378 cP
1098 LG-B1801 DGA-11822-01 1800B HE-B1801 C2 Level Level gauge C2 Liquid - - - 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 1398.0 kg/m3 0.55 cP
38 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1099 LG-B1811 DGA-11822-01 1800B CL-B1811 Level Level gauge CM Liquid - - - 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 1160.0 kg/m3 0.214 cP
1103 PG-B1801 DGA-11822-01 1800B HE-B1801 C1 Press. Pressure gauge C1 Gas - - - 2.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 0.0 deg C 2.3 kg/Nm3 0.01 cP
1104 PG-B1811 DGA-11822-01 1800B CL-B1811 Btm Press. Pressure gauge CM Vapor - - - 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 2.3 kg/Nm3 0.014 cP
1105 PG-B1812 DGA-11822-01 1800B HE-B1811 S4 Feed Press. Pressure gauge S4 Vapor 1820 kg/h 1400.0 kg/h 420 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
HE-B1812/1,2 C1 Discharge
1106 PG-B1813 DGA-11822-01 1800B Pressure gauge C1 Gas 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 2.3 kg/Nm3 0.014 cP
Press.
1107 PI-B1811 DGA-11822-01 1800B CL-B1811 Btm Press. Pressure transmitter CM Vapor - - - 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 2.3 kg/Nm3 0.014 cP
1108 PI-B1812 DGA-11822-01 1800B CL-B1811 C1 Outlet Press. Pressure transmitter C1 Gas 3762.72 Nm3/h 2894.4 Nm3/h 868.32 Nm3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 2.3 kg/Nm3 0.014 cP
HE-B1812/1,2 C1 Discharge
1109 PIC-B1813 DGA-11822-01 1800B Pressure transmitter C1 Gas 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 42.0 deg C 2.3 kg/Nm3 0.014 cP
Press.
1120 EV-B1821 DGA-11822-02 1800B HE-B1826 C2 Outlet EV Automatic Valve C2 Liquid 4.29 m3/h 3.3 m3/h 0.99 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1335.0 kg/m3 0.447 cP
1121 FG-B1821 DGA-11822-02 1800B HE-B1825 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1122 FI-B1824 DGA-11822-02 1800B CL-B1821 C2 Feed Flow Flowmeter C2 Liquid 0.52 m3/h 0.4 m3/h 0.12 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
1123 FIC-B1821 DGA-11822-02 1800B CL-B1821 CM Feed Flow Flowmeter CM Liquid 6.63 m3/h 5.1 m3/h 1.53 m3/h 8.00 kgf/cm2G 5.70 kgf/cm2G 80.0 deg C 65.0 deg C 1296.0 kg/m3 0.313 cP
1125 FIC-B1822 DGA-11822-02 1800B CL-B1821 CM Feed Flow Flowmeter CM Liquid 10.00 kgf/cm2G 8.30 kgf/cm2G 140.0 deg C 123.0 deg C 1160.0 kg/m3 0.214 cP
1127 FIC-B1823 DGA-11822-02 1800B HE-B1821 S2 Feed Flow Flowmeter S2 Vapor 85.8 kg/h 66.0 kg/h 19.8 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
39 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
PU-B1821/A,B C2 Discharge
1129 FIC-B1825 DGA-11822-02 1800B Flowmeter C2 Liquid 130 L/h 100.0 L/h 30 L/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
Flow
PU-B1821/A,B C2 Discharge
1130 FIC-B1825V DGA-11822-02 1800B Control Valve C2 Liquid 0.13 m3/h 0.1 m3/h 0.03 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 0.5 kg/cm2 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
Control Valve
1131 FIC-B1826 DGA-11822-02 1800B CL-B1822 CM Feed Flow Flowmeter CM Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 7.00 kgf/cm2G 5.07 kgf/cm2G 80.0 deg C 62.0 deg C 1307.0 kg/m3 0.321 cP
1133 FIC-B1827 DGA-11822-02 1800B HE-B1823 S2 Feed Flow Flowmeter S2 Vapor 4082 kg/h 3140.0 kg/h 942 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1135 FIC-B1828 DGA-11822-02 1800B CL-B1831 CM Feed Flow Flowmeter CM Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 8.00 kgf/cm2G 5.42 kgf/cm2G 100.0 deg C 81.0 deg C 1386.0 kg/m3 0.339 cP
1137 FIC-B1829 DGA-11822-02 1800B HE-B1826 C2 Outlet Flow Flowmeter C2 Liquid 4.29 m3/h 3.3 m3/h 0.99 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 15.0 deg C 1335.0 kg/m3 0.447 cP
1139 FIC-B1830 DGA-11822-02 1800B CL-B1822 C2 Feed Flow Flowmeter C2 Liquid 17.94 m3/h 13.8 m3/h 4.14 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
1141 FIC-B1831 DGA-11822-02 1800B PU-B1823/A,B C2 Outlet Flow Flowmeter C2 Liquid 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
PU-B1823/A,B C2 Outlet
1142 FIC-B1831V DGA-11822-02 1800B Control Valve C2 Liquid 8.00 kgf/cm2G 6.04 kgf/cm2G 0.5 kg/cm2 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
Control Valve
1143 LG-B1821 DGA-11822-02 1800B CL-B1821 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 80.0 deg C 62.0 deg C 1306.0 kg/m3 0.321 cP
1144 LG-B1822 DGA-11822-02 1800B TK-B1821 Level Level gauge C2 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
1145 LG-B1823 DGA-11822-02 1800B CL-B1822 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 100.0 deg C 81.0 deg C 1385.0 kg/m3 0.339 cP
1146 LG-B1824 DGA-11822-02 1800B TK-B1822 Level Level gauge C2 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
40 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1152 PG-B1821 DGA-11822-02 1800B CL-B1821 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 80.0 deg C 62.0 deg C 3.8 kg/Nm3 0.011 cP
1153 PG-B1822 DGA-11822-02 1800B HE-B1821 S2 Feed Press. Pressure gauge S2 Vapor 85.8 kg/h 66.0 kg/h 19.8 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1154 PG-B1823A DGA-11822-02 1800B PU-B1821/A Discharge Press. Pressure gauge C2 Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
1155 PG-B1823B DGA-11822-02 1800B PU-B1821/B Discharge Press. Pressure gauge C2 Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
1156 PG-B1824A DGA-11822-02 1800B PU-B1822/A Discharge Press. Pressure gauge CM Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 7.00 kgf/cm2G 5.07 kgf/cm2G 80.0 deg C 62.0 deg C 1307.0 kg/m3 0.321 cP
1157 PG-B1824B DGA-11822-02 1800B PU-B1822/B Discharge Press. Pressure gauge CM Liquid 6.5 m3/h 5.0 m3/h 1.5 m3/h 7.00 kgf/cm2G 5.07 kgf/cm2G 80.0 deg C 62.0 deg C 1307.0 kg/m3 0.321 cP
1158 PG-B1825 DGA-11822-02 1800B CL-B1822 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 100.0 deg C 81.0 deg C 3.8 kg/Nm3 0.011 cP
1159 PG-B1826 DGA-11822-02 1800B HE-B1823 S2 Feed Press. Pressure gauge S2 Vapor 4082 kg/h 3140.0 kg/h 942 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1160 PG-B1827A DGA-11822-02 1800B PU-B1823/A Discharge Press. Pressure gauge C2 Liquid 17.94 m3/h 13.8 m3/h 4.14 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
1161 PG-B1827B DGA-11822-02 1800B PU-B1823/B Discharge Press. Pressure gauge C2 Liquid 17.94 m3/h 13.8 m3/h 4.14 m3/h 8.00 kgf/cm2G 6.04 kgf/cm2G 60.0 deg C 50.0 deg C 1269.0 kg/m3 0.328 cP
1162 PG-B1828A DGA-11822-02 1800B PU-B1824/A Discharge Press. Pressure gauge CM Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 8.00 kgf/cm2G 5.42 kgf/cm2G 100.0 deg C 81.0 deg C 1386.0 kg/m3 0.339 cP
1163 PG-B1828B DGA-11822-02 1800B PU-B1824/B Discharge Press. Pressure gauge CM Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 8.00 kgf/cm2G 5.42 kgf/cm2G 100.0 deg C 81.0 deg C 1386.0 kg/m3 0.339 cP
1164 PG-B1829 DGA-11822-02 1800B HE-B1822 C2 Press. Pressure gauge C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
1165 PG-B1830 DGA-11822-02 1800B HE-B1824/1,2 C2 Outlet Press. Pressure gauge C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
1166 PI-B1821 DGA-11822-02 1800B CL-B1821 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 80.0 deg C 62.0 deg C 3.8 kg/Nm3 0.011 cP
1167 PI-B1823 DGA-11822-02 1800B CL-B1822 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 100.0 deg C 81.0 deg C 3.8 kg/Nm3 0.011 cP
1168 PI-B1824 DGA-11822-02 1800B CL-B1821 Top C2 Press. Pressure transmitter C2 Vapor 205.66 Nm3/h 158.2 Nm3/h 47.46 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
1169 PI-B1826 DGA-11822-02 1800B HE-B1824/1,2 C2 Feed Press. Pressure transmitter C2 Vapor 5994.69 Nm3/h 4611.3 Nm3/h 1383.39 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
1170 PIC-B1822 DGA-11822-02 1800B HE-B1822 C2 Press. Pressure transmitter C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
41 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1173 PIC-B1825 DGA-11822-02 1800B HE-B1824/1,2 C2 Outlet Press. Pressure transmitter C2 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 50.0 deg C 3.8 kg/Nm3 0.011 cP
1176 SV-B1821 DGA-11822-02 1800B HE-B1822 PW Feed SV Automatic Valve PW Liquid 0 m3/h 0.0 m3/h 0 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1177 SV-B1822 DGA-11822-02 1800B HE-B1824/1,2 PW Feed SV Automatic Valve PW Liquid 0 m3/h 0.0 m3/h 0 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1186 EV-B1831 DGA-11822-03 1800B HE-B1835 C3 Outlet EV Automatic Valve C3 Liquid 1.443 m3/h 1.1 m3/h 0.333 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1498.0 kg/m3 0.587 cP
1187 FG-B1831 DGA-11822-03 1800B HE-B1833 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1188 FI-B1833 DGA-11822-03 1800B CL-B1831 C3 Feed Flow Flowmeter C3 Liquid 6.11 m3/h 4.7 m3/h 1.41 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1189 FIC-B1832 DGA-11822-03 1800B PU-B1832/A,B CM Outlet Flow Flowmeter CM Liquid 247 L/h 190.0 L/h 57 L/h 8.00 kgf/cm2G 5.49 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
PU-B1832/A,B CM Outlet
1190 FIC-B1832V DGA-11822-03 1800B Control Valve CM Liquid 0.247 m3/h 0.2 m3/h 0.057 m3/h 8.00 kgf/cm2G 5.49 kgf/cm2G 0.5 kg/cm2 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
Control Valve
1191 FIC-B1834 DGA-11822-03 1800B HE-B1836 C3 Outlet Flow Flowmeter C3 Liquid 0.442 m3/h 0.3 m3/h 0.102 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 60.0 deg C 40.0 deg C 1452.0 kg/m3 0.456 cP
1193 FIC-B1835 DGA-11822-03 1800B HE-B1835 C3 Outlet Flow Flowmeter C3 Liquid 1.443 m3/h 1.1 m3/h 0.333 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 60.0 deg C 15.0 deg C 1498.0 kg/m3 0.587 cP
1195 FIC-B1836 DGA-11822-03 1800B CL-B1832 C3 Feed Flow Flowmeter C3 Liquid 6.903 m3/h 5.3 m3/h 1.593 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1197 FIC-B1837 DGA-11822-03 1800B PU-B1831/A,B C3 Outlet Flow Flowmeter C3 Liquid 182 L/h 140.0 L/h 42 L/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
PU-B1831/A,B C3 Outlet
1198 FIC-B1837V DGA-11822-03 1800B Control Valve C3 Liquid 0.182 m3/h 0.1 m3/h 0.042 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 0.5 kg/cm2 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
Control Valve
1199 FIC-B1838 DGA-11822-03 1800B HE-B1831 S2 Feed Flow Flowmeter S2 Vapor 1384.5 kg/h 1065.0 kg/h 319.5 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1201 LG-B1831 DGA-11822-03 1800B CL-B1831 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
1202 LG-B1832 DGA-11822-03 1800B CL-B1832 Level Level gauge C3 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
42 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1203 LG-B1833 DGA-11822-03 1800B TK-B1831 Level Level gauge C3 Liquid - - - 2.00 kgf/cm2G 0.00 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1206 LIC-B1832 DGA-11822-03 1800B CL-B1832 Btm Level Differential press. Transmitter
C3 Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1208 PG-B1831 DGA-11822-03 1800B CL-B1831 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 120.0 deg C 100.0 deg C 5.3 kg/Nm3 0.012 cP
1209 PG-B1832 DGA-11822-03 1800B HE-B1831 S2 Feed Press. Pressure gauge S2 Vapor 1384.5 kg/h 1065.0 kg/h 319.5 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1210 PG-B1833A DGA-11822-03 1800B PU-B1832/A Discharge Press. Pressure gauge CM Liquid 0.247 m3/h 0.2 m3/h 0.057 m3/h 8.00 kgf/cm2G 5.49 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
1211 PG-B1833B DGA-11822-03 1800B PU-B1832/B Discharge Press. Pressure gauge CM Liquid 0.247 m3/h 0.2 m3/h 0.057 m3/h 8.00 kgf/cm2G 5.49 kgf/cm2G 120.0 deg C 100.0 deg C 1415.0 kg/m3 0.363 cP
1212 PG-B1834 DGA-11822-03 1800B CL-B1832 Btm Press. Pressure gauge C3 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 5.3 kg/Nm3 0.012 cP
1213 PG-B1835A DGA-11822-03 1800B PU-B1833/A Discharge Press. Pressure gauge C3 Liquid 9.1 m3/h 7.0 m3/h 2.1 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1214 PG-B1835B DGA-11822-03 1800B PU-B1833/B Discharge Press. Pressure gauge C3 Liquid 9.1 m3/h 7.0 m3/h 2.1 m3/h 7.00 kgf/cm2G 5.41 kgf/cm2G 90.0 deg C 75.0 deg C 1384.0 kg/m3 0.341 cP
1215 PG-B1836A DGA-11822-03 1800B PU-B1831/A Discharge Press. Pressure gauge C3 Liquid 7.085 m3/h 5.5 m3/h 1.635 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1216 PG-B1836B DGA-11822-03 1800B PU-B1831/B Discharge Press. Pressure gauge C3 Liquid 7.085 m3/h 5.5 m3/h 1.635 m3/h 9.00 kgf/cm2G 6.25 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1217 PI-B1831 DGA-11822-03 1800B CL-B1831 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 120.0 deg C 100.0 deg C 5.3 kg/Nm3 0.012 cP
1218 PI-B1832 DGA-11822-03 1800B CL-B1832 C3 Feed Press. Pressure transmitter C3 Vapor 1877.72 Nm3/h 1444.4 Nm3/h 433.32 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 90.0 deg C 75.0 deg C 5.3 kg/Nm3 0.012 cP
1219 PI-B1833 DGA-11822-03 1800B CL-B1832 TOP C3 Press. Pressure transmitter C3 Vapor - - - 2.00 kgf/cm2G 0.00 kgf/cm2G 80.0 deg C 61.0 deg C 5.3 kg/Nm3 0.012 cP
1220 SV-B1831 DGA-11822-03 1800B HE-B1832 PW Feed SV Automatic Valve PW Liquid 149.11 m3/h 114.7 m3/h 34.41 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1232 EV-B1841 DGA-11822-04 1800B HE-B1845 C4 Outlet EV Automatic Valve C4 Liquid 0.182 m3/h 0.1 m3/h 0.042 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G - 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1235 FG-B1843 DGA-11822-04 1800B HE-B1844 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
43 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1236 FG-B1844 DGA-11822-04 1800B HE-B1843 HB Feed Flow Area Flowmeter HB Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 6.00 kgf/cm2G 4.03 kgf/cm2G 120.0 deg C 105.0 deg C 1488.0 kg/m3 0.495 cP
1237 FIC-B1841 DGA-11822-04 1800B CL-B1841 S2 Feed Flow Flowmeter S2 Vapor 70.2 kg/h 54.0 kg/h 16.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1239 FIC-B1842 DGA-11822-04 1800B CL-B1841 C4 Feed Flow Flowmeter C4 Liquid 325 L/h 250.0 L/h 75 L/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1241 FIC-B1843 DGA-11822-04 1800B PU-B1841/A,B C4 Outlet Flow Flowmeter C4 Liquid 52 L/h 40.0 L/h 12 L/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
PU-B1841/A,B C4 Outlet
1242 FIC-B1843V DGA-11822-04 1800B Control Valve C4 Liquid 0.052 m3/h 0.0 m3/h 0.012 m3/h 9.00 kgf/cm2G 6.20 kgf/cm2G 0.5 kg/cm2 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
Control Valve
1243 FIC-B1844 DGA-11822-04 1800B CL-B1842 C4 Feed Flow Flowmeter C4 Liquid 195 L/h 150.0 L/h 45 L/h 7.00 kgf/cm2G 5.09 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/m3 0.427 cP
1245 FIC-B1845 DGA-11822-04 1800B CL-B1842 S4 Feed Flow Flowmeter S4 Vapor 274.3 kg/h 211.0 kg/h 63.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1247 FIC-B1846 DGA-11822-04 1800B CL-B1842 C4 Feed Flow Flowmeter C4 Liquid 0.793 m3/h 0.6 m3/h 0.183 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
1249 FIC-B1847 DGA-11822-04 1800B PU-B1843/A,B C4 Outlet Flow Flowmeter C4 Liquid 182 L/h 140.0 L/h 42 L/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
PU-B1843/A,B C4 Outlet
1250 FIC-B1847V DGA-11822-04 1800B Control Valve C4 Liquid 0.182 m3/h 0.1 m3/h 0.042 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 3 kg/cm2 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
Control Valve
1251 LG-B1841 DGA-11822-04 1800B CL-B1841 Level Level gauge CM Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/Nm3 0.427 cP
1252 LG-B1842 DGA-11822-04 1800B TK-B1841 Level Level gauge C4 Liquid - - - 2.00 kgf/cm2G 0.10 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1253 LG-B1843 DGA-11822-04 1800B CL-B1842 Level Level gauge HB Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 105.0 deg C 1488.0 kg/m3 0.495 cP
1254 LG-B1844 DGA-11822-04 1800B TK-B1842 Level Level gauge C4 Liquid - - - 2.00 kgf/cm2G 0.10 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
44 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1259 PG-B1841 DGA-11822-04 1800B CL-B1841 Btm Press. Pressure gauge CM Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 110.0 deg C 90.0 deg C 5.3 kg/Nm3 0.012 cP
1260 PG-B1842 DGA-11822-04 1800B CL-B1841 S2 Feed Press. Pressure gauge S2 Vapor 70.2 kg/h 54.0 kg/h 16.2 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1261 PG-B1843A DGA-11822-04 1800B PU-B1841/A Discharge Press. Pressure gauge C4 Liquid 0.377 m3/h 0.3 m3/h 0.087 m3/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1262 PG-B1843B DGA-11822-04 1800B PU-B1841/B Discharge Press. Pressure gauge C4 Liquid 0.377 m3/h 0.3 m3/h 0.087 m3/h 9.00 kgf/cm2G 6.20 kgf/cm2G 80.0 deg C 61.0 deg C 1412.0 kg/m3 0.38 cP
1263 PG-B1844A DGA-11822-04 1800B PU-B1842/A Discharge Press. Pressure gauge C4 Liquid 0.195 m3/h 0.2 m3/h 0.045 m3/h 7.00 kgf/cm2G 5.09 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/m3 0.427 cP
1264 PG-B1844B DGA-11822-04 1800B PU-B1842/B Discharge Press. Pressure gauge C4 Liquid 0.195 m3/h 0.2 m3/h 0.045 m3/h 7.00 kgf/cm2G 5.09 kgf/cm2G 110.0 deg C 90.0 deg C 1457.0 kg/m3 0.427 cP
1265 PG-B1845 DGA-11822-04 1800B CL-B1842 Btm Press. Pressure gauge C4 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 105.0 deg C 6.9 kg/Nm3 0.012 cP
1266 PG-B1846 DGA-11822-04 1800B CL-B1842 S4 Feed Press. Pressure gauge S4 Vapor 274.3 kg/h 211.0 kg/h 63.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1267 PG-B1847 DGA-11822-04 1800B PU-B1844 Discharge Press. Pressure gauge HB Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 6.00 kgf/cm2G 4.03 kgf/cm2G 120.0 deg C 105.0 deg C 1488.0 kg/m3 0.495 cP
1268 PG-B1848A DGA-11822-04 1800B PU-B1843/A Discharge Press. Pressure gauge C4 Liquid 0.975 m3/h 0.8 m3/h 0.225 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
1269 PG-B1848B DGA-11822-04 1800B PU-B1843/B Discharge Press. Pressure gauge C4 Liquid 0.975 m3/h 0.8 m3/h 0.225 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G 90.0 deg C 77.0 deg C 1484.0 kg/m3 0.485 cP
1270 PI-B1841 DGA-11822-04 1800B CL-B1841 Btm Press. Pressure transmitter CM Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 110.0 deg C 90.0 deg C 5.3 kg/Nm3 0.012 cP
1271 PI-B1842 DGA-11822-04 1800B HE-B1841 C4 Feed Press. Pressure transmitter C4 Vapor 97.5 Nm3/h 75.0 Nm3/h 22.5 Nm3/h 2.00 kgf/cm2G 0.10 kgf/cm2G 80.0 deg C 61.0 deg C 5.3 kg/Nm3 0.012 cP
1272 PI-B1843 DGA-11822-04 1800B CL-B1842 Btm Press. Pressure transmitter C4 Vapor - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 105.0 deg C 6.9 kg/Nm3 0.012 cP
1273 PI-B1844 DGA-11822-04 1800B HE-B1842 C4 Feed Press. Pressure transmitter C4 Vapor 212.03 Nm3/h 163.1 Nm3/h 48.93 Nm3/h 2.00 kgf/cm2G 0.10 kgf/cm2G 90.0 deg C 77.0 deg C 6.9 kg/Nm3 0.012 cP
1284 EV-1901 DGA-11920-01 1900 HE-1901 WCS Feed EV Automatic Valve WCS Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.03 kgf/cm2G - 60.0 deg C 35.0 deg C 1081.0 kg/m3 1.105 cP
1285 EV-1902 DGA-11920-01 1900 CL-1901 S4 Feed EV Automatic Valve S4 Vapor 807.3 kg/h 621.0 kg/h 186.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1286 FI-1903 DGA-11920-01 1900 CL-1901 MeOH Feed Flow Flowmeter MeOH Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 6.00 kgf/cm2G 4.54 kgf/cm2G 70.0 deg C 50.0 deg C 988.0 kg/m3 0.516 cP
1287 FIC-1901 DGA-11920-01 1900 HE-1901 WCS Feed Flow Flowmeter WCS Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.03 kgf/cm2G 60.0 deg C 35.0 deg C 1081.0 kg/m3 1.105 cP
1289 FIC-A1904 DGA-11920-01 1900 TK-A2151 MeOH Feed Flow Flowmeter MeOH Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 6.00 kgf/cm2G 4.54 kgf/cm2G 70.0 deg C 50.0 deg C 988.0 kg/m3 0.516 cP
45 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1291 FIC-B1904 DGA-11920-01 1900 TK-B2151 MeOH Feed Flow Flowmeter MeOH Liquid 0.26 m3/h 0.2 m3/h 0.06 m3/h 6.00 kgf/cm2G 4.54 kgf/cm2G 70.0 deg C 50.0 deg C 988.0 kg/m3 0.516 cP
1293 FICQ-1902 DGA-11920-01 1900 CL-1901 S4 Feed Flow Flowmeter S4 Vapor 807.3 kg/h 621.0 kg/h 186.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1294 FICQ-1902V DGA-11920-01 1900 CL-1901 S4 Feed Control Valve Control Valve S4 Vapor 807.3 kg/h 621.0 kg/h 186.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 0.1 kg/cm2 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1295 LG-1901 DGA-11920-01 1900 CL-1901 WCS Level Level gauge WCS Liquid - - - 2.00 kgf/cm2G 0.20 kgf/cm2G 120.0 deg C 100.0 deg C 1098.0 kg/m3 0.497 cP
1296 LG-1902 DGA-11920-01 1900 TK-1901 WCS Level Level gauge WCS Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 35.0 deg C 1081.0 kg/m3 1.105 cP
1297 LG-1903 DGA-11920-01 1900 TK-1902 MeOH Level Level gauge MeOH Liquid - - - F.L + 0.03 kgf/cm2G
ATM 70.0 deg C 50.0 deg C 988.0 kg/m3 0.516 cP
1298 LI-1902 DGA-11920-01 1900 TK-1901 WCS Level Liquid level TransmitterWCS Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 35.0 deg C 1081.0 kg/m3 1.105 cP
1299 LIC-1901 DGA-11920-01 1900 CL-1901 WCS Level Differential press. Transmitter
WCS Liquid - - - 2.00 kgf/cm2G 0.20 kgf/cm2G 120.0 deg C 100.0 deg C 1098.0 kg/m3 0.497 cP
1301 LIC-1903 DGA-11920-01 1900 TK-1902 MeOH Level Liquid level TransmitterMeOH Liquid - - - F.L + 0.03 kgf/cm2G
ATM 70.0 deg C 50.0 deg C 988.0 kg/m3 0.516 cP
1303 PG-1901A DGA-11920-01 1900 PU-1901/A Discharge Press. Pressure gauge WCS Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.03 kgf/cm2G 60.0 deg C 35.0 deg C 1081.0 kg/m3 1.105 cP
1304 PG-1901B DGA-11920-01 1900 PU-1901/B Discharge Press. Pressure gauge WCS Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.03 kgf/cm2G 60.0 deg C 35.0 deg C 1081.0 kg/m3 1.105 cP
1305 PG-1902A DGA-11920-01 1900 PU-1902/A Discharge Press. Pressure gauge WCS Liquid 1.82 m3/h 1.4 m3/h 0.42 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 90.0 deg C 70.0 deg C 1120.0 kg/m3 0.718 cP
1306 PG-1902B DGA-11920-01 1900 PU-1902/B Discharge Press. Pressure gauge WCS Liquid 1.82 m3/h 1.4 m3/h 0.42 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 90.0 deg C 70.0 deg C 1120.0 kg/m3 0.718 cP
1307 PG-1903A DGA-11920-01 1900 PU-1903/A Discharge Press. Pressure gauge MeOH Liquid 0.52 m3/h 0.4 m3/h 0.12 m3/h 6.00 kgf/cm2G 4.54 kgf/cm2G 70.0 deg C 50.0 deg C 988.0 kg/m3 0.516 cP
1308 PG-1903B DGA-11920-01 1900 PU-1903/B Discharge Press. Pressure gauge MeOH Liquid 0.52 m3/h 0.4 m3/h 0.12 m3/h 6.00 kgf/cm2G 4.54 kgf/cm2G 70.0 deg C 50.0 deg C 988.0 kg/m3 0.516 cP
1309 PG-1904 DGA-11920-01 1900 CL-1901 WCS Press. Pressure gauge WCS Gas - - - 2.00 kgf/cm2G 0.20 kgf/cm2G 120.0 deg C 100.0 deg C 0.8 kg/Nm3 0.013 cP
1310 PG-1905 DGA-11920-01 1900 CL-1901 WCS Top Press. Pressure gauge MeOH Vapor 646.36 Nm3/h 497.2 Nm3/h 149.16 Nm3/h 2.00 kgf/cm2G 0.05 kgf/cm2G 120.0 deg C 100.0 deg C 0.8 kg/Nm3 0.013 cP
1311 PG-1906 DGA-11920-01 1900 CL-1901 S4 Feed Press. Pressure gauge S4 Vapor 807.3 kg/h 621.0 kg/h 186.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
46 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1315 EV-2101 DGA-12120-01 2100 TK-2101 MeOH Outlet EV Automatic Valve MeOH Liquid 78 m3/h 60.0 m3/h 18 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1316 EV-2102 DGA-12120-01 2100 TK-2102 MeOH Outlet EV Automatic Valve MeOH Liquid 7.41 m3/h 5.7 m3/h 1.71 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1317 FG-2101 DGA-12120-01 2100 MeOH Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1318 FG-2102 DGA-12120-01 2100 MeOH Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1319 FIQ-2101 DGA-12120-01 2100 TK-2101 MeOH Feed Flow Flowmeter MeOH Liquid 78 m3/h 60.0 m3/h 18 m3/h 3.00 kgf/cm2G 1.75 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1320 LG-2101 DGA-12120-01 2100 TK-2101 Level Level gauge MeOH Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1321 LG-2102 DGA-12120-01 2100 TK-2102 Level Level gauge MeOH Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1324 PG-2101A DGA-12120-01 2100 PU-2101/A Discharge Press. Pressure gauge MeOH Liquid 78 m3/h 60.0 m3/h 18 m3/h 3.00 kgf/cm2G 1.75 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1325 PG-2101B DGA-12120-01 2100 PU-2101/B Discharge Press. Pressure gauge MeOH Liquid 78 m3/h 60.0 m3/h 18 m3/h 3.00 kgf/cm2G 1.75 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1326 PG-2102A DGA-12120-01 2100 PU-2102/A Discharge Press. Pressure gauge MeOH Liquid 78 m3/h 60.0 m3/h 18 m3/h 3.00 kgf/cm2G 1.65 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1327 PG-2102B DGA-12120-01 2100 PU-2102/B Discharge Press. Pressure gauge MeOH Liquid 78 m3/h 60.0 m3/h 18 m3/h 3.00 kgf/cm2G 1.65 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1328 PG-2103A DGA-12120-01 2100 PU-2103/A Discharge Press. Pressure gauge MeOH Liquid 7.41 m3/h 5.7 m3/h 1.71 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1329 PG-2103B DGA-12120-01 2100 PU-2103/B Discharge Press. Pressure gauge MeOH Liquid 7.41 m3/h 5.7 m3/h 1.71 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1330 PI-2101 DGA-12120-01 2100 TK-2101 Press. Pressure transmitter MeOH Vapor - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1331 PI-2102 DGA-12120-01 2100 TK-2102 Press. Pressure transmitter MeOH Vapor - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1332 SV-2101 DGA-12120-01 2100 TK-2101 MeOH Feed SV Automatic Valve MeOH Liquid 78 m3/h 60.0 m3/h 18 m3/h 3.00 kgf/cm2G 1.75 kgf/cm2G - 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1333 EV-A2151 DGA-12121-01 2100A TK-A2151 CHA Outlet EV Automatic Valve CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 2.00 kgf/cm2G 0.02 kgf/cm2G - 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1334 EV-A2152 DGA-12121-01 2100A TK-A2152 DHA Outlet EV Automatic Valve DHA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 2.00 kgf/cm2G 0.02 kgf/cm2G - 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1335 EV-A2153 DGA-12121-01 2100A PU-A2151/A,B CHA Outlet EV Automatic Valve CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G - 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1336 FG-A2151 DGA-12121-01 2100A TK-A2152 DHA Feed Flow Area Flowmeter DHA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 4.00 kgf/cm2G 2.30 kgf/cm2G 60.0 deg C 40.0 deg C 1066.0 kg/m3 0.815 cP
47 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1337 FG-A2152 DGA-12121-01 2100A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1338 FI-A2154 DGA-12121-01 2100A TK-A2151 CHA Feed Flow Flowmeter CHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
1339 FIC-A2151 DGA-12121-01 2100A HE-A2151/1,2 CHA Feed Flow Flowmeter CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1341 FIC-A2153 DGA-12121-01 2100A HE-2401 DHA Feed Flow Flowmeter DHA Liquid 1.17 m3/h 0.9 m3/h 0.27 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1343 LG-A2151 DGA-12121-01 2100A TK-A2151 Level Level gauge CHA Liquid - - - 2.00 kgf/cm2G 0.02 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1344 LG-A2152 DGA-12121-01 2100A TK-A2152 Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.02 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1345 LG-A2153 DGA-12121-01 2100A TS-A2151 Level Level gauge DHA Liquid - - - F.L ATM 60.0 deg C 40.0 deg C 1066.0 kg/m3 0.815 cP
1350 PG-A2151A DGA-12121-01 2100A PU-A2151/A Discharge Press. Pressure gauge CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1351 PG-A2151B DGA-12121-01 2100A PU-A2151/B Discharge Press. Pressure gauge CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1352 PG-A2152A DGA-12121-01 2100A PU-A2152/A Discharge Press. Pressure gauge DHA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1353 PG-A2152B DGA-12121-01 2100A PU-A2152/B Discharge Press. Pressure gauge DHA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1354 QI-A2151 DGA-12121-01 2100A TK-A2152 DHA Feed Density Densitometer DHA Liquid 4.00 kgf/cm2G 2.30 kgf/cm2G 60.0 deg C 40.0 deg C 1066.0 kg/m3 0.815 cP
1357 EV-B2151 DGA-12122-01 2100B TK-B2151 CHA Outlet EV Automatic Valve CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 2.00 kgf/cm2G 0.02 kgf/cm2G - 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1358 EV-B2152 DGA-12122-01 2100B TK-B2152 DHA Outlet EV Automatic Valve DHA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 2.00 kgf/cm2G 0.02 kgf/cm2G - 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1359 EV-B2153 DGA-12122-01 2100B PU-B2151/A,B CHA Outlet EV Automatic Valve CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G - 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1360 FG-B2151 DGA-12122-01 2100B TK-B2152 DHA Feed Flow Area Flowmeter DHA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 4.00 kgf/cm2G 2.30 kgf/cm2G 60.0 deg C 40.0 deg C 1066.0 kg/m3 0.815 cP
48 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1361 FG-B2152 DGA-12122-01 2100B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1362 FI-B2154 DGA-12122-01 2100B TK-B2151 CHA Feed Flow Flowmeter CHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 4.27 kgf/cm2G 70.0 deg C 50.0 deg C 1141.0 kg/m3 1.077 cP
1363 FIC-B2151 DGA-12122-01 2100B HE-B2151/1,2 CHA Feed Flow Flowmeter CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1365 FIC-B2153 DGA-12122-01 2100B HE-2401 DHA Feed Flow Flowmeter DHA Liquid 1.17 m3/h 0.9 m3/h 0.27 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1368 LG-B2151 DGA-12122-01 2100B TK-B2151 Level Level gauge CHA Liquid - - - 2.00 kgf/cm2G 0.02 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1369 LG-B2152 DGA-12122-01 2100B TK-B2152 Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.02 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1370 LG-B2153 DGA-12122-01 2100B TS-B2151 Level Level gauge DHA Liquid - - - F.L ATM 60.0 deg C 40.0 deg C 1066.0 kg/m3 0.815 cP
1375 PG-B2151A DGA-12122-01 2100B PU-B2151/A Discharge Press. Pressure gauge CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1376 PG-B2151B DGA-12122-01 2100B PU-B2151/B Discharge Press. Pressure gauge CHA Liquid 18.72 m3/h 14.4 m3/h 4.32 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 60.0 deg C 40.0 deg C 1129.0 kg/m3 1.151 cP
1377 PG-B2152A DGA-12122-01 2100B PU-B2152/A Discharge Press. Pressure gauge DHA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1378 PG-B2152B DGA-12122-01 2100B PU-B2152/B Discharge Press. Pressure gauge DHA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1379 QI-B2151 DGA-12122-01 2100B TK-B2152 DHA Feed Density Densitometer DHA Liquid 4.00 kgf/cm2G 2.30 kgf/cm2G 60.0 deg C 40.0 deg C 1066.0 kg/m3 0.815 cP
1382 EV-A2201 DGA-12221-01 2200A RE-A2201 CHA Feed EV Automatic Valve CHA Liquid/Gas 24063 kg/h 18510.0 kg/h 5553 kg/h 10.00 kgf/cm2G 7.97 kgf/cm2G - 120.0 deg C 100.0 deg C 1090.0 kg/m3 0.516 cP
1383 EV-A2202 DGA-12221-01 2200A RE-A2201 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1384 EV-A2203 DGA-12221-01 2200A RE-A2201 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
49 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1385 EV-A2204 DGA-12221-01 2200A RE-A2201 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1386 EV-A2205 DGA-12221-01 2200A RE-A2201 DHA Outlet EV Automatic Valve DHA Liquid 17.55 m3/h 13.5 m3/h 4.05 m3/h 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1387 EV-A2206 DGA-12221-01 2200A RE-A2201 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1388 EV-A2207 DGA-12221-01 2200A HE-A2201/1,2 S4 Feed EV Automatic Valve S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1389 FG-A2201 DGA-12221-01 2200A RE-A2201 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1390 FG-A2202 DGA-12221-01 2200A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1391 FG-A2203 DGA-12221-01 2200A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1392 FG-A2204 DGA-12221-01 2200A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1393 FG-A2205 DGA-12221-01 2200A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1394 FIC-A2201 DGA-12221-01 2200A HE-A2201/1,2 S4 Feed Flow Flowmeter S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1398 PG-A2201 DGA-12221-01 2200A RE-A2201 CHA Feed Press. Pressure gauge CHA Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 120.0 deg C 100.0 deg C 1090.0 kg/m3 0.516 cP
1399 PG-A2202 DGA-12221-01 2200A RE-A2201 C1 Outlet Press. Pressure gauge C1 Gas 4614.87 Nm3/h 3549.9 Nm3/h 1064.97 Nm3/h 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1400 PG-A2203 DGA-12221-01 2200A HE-A2201/1,2 S4 Feed Press. Pressure gauge S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1401 PG-A2204 DGA-12221-01 2200A HE-A2201/1,2 S4 Feed Press. Pressure gauge S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1402 PIC-A2201 DGA-12221-01 2200A RE-A2201 C1 Outlet Press. Pressure transmitter C1 Gas 4614.87 Nm3/h 3549.9 Nm3/h 1064.97 Nm3/h 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1403 PIC-A2201V/B DGA-12221-01 2200A C1 Line EG Outlet Control Valve Control Valve EG Vapor 4.00 kgf/cm2G 2.70 kgf/cm2G 2.68 kg/cm2 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1404 PIC-A2202 DGA-12221-01 2200A RE-A2201 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1406 PIC-A2203 DGA-12221-01 2200A RE-A2201 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
50 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1408 SV-A2201 DGA-12221-01 2200A CHA Line MeOH Feed SV Automatic Valve MeOH Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G - 120.0 deg C 70.0 deg C 730.0 kg/m3 0.307 cP
1409 SV-A2202 DGA-12221-01 2200A CHA Line MeOH Feed SV Automatic Valve MeOH Vapor 2008.63 Nm3/h 1545.1 Nm3/h 463.53 Nm3/h 10.00 kgf/cm2G 7.62 kgf/cm2G - 120.0 deg C 106.0 deg C 1.4 kg/Nm3 0.012 cP
1410 SV-A2203 DGA-12221-01 2200A DHA Line EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1411 SV-A2204 DGA-12221-01 2200A DHA Line EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1412 SV-A2205 DGA-12221-01 2200A C1 Line EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1413 SV-A2206 DGA-12221-01 2200A RE-A2201 CA Feed SV Automatic Valve CA Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G - 60.0 deg C 30.0 deg C 7.9 kg/m3 0.018 cP
1419 EV-A2211 DGA-12221-02 2200A RE-A2201 DHA Feed EV Automatic Valve DHA Liquid 17.55 m3/h 13.5 m3/h 4.05 m3/h 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1420 EV-A2212 DGA-12221-02 2200A RE-A2201 C1 Feed EV Automatic Valve C1 Gas 4614.87 Nm3/h 3549.9 Nm3/h 1064.97 Nm3/h 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1421 EV-A2213 DGA-12221-02 2200A RE-A2202 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1422 EV-A2214 DGA-12221-02 2200A RE-A2202 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1423 EV-A2215 DGA-12221-02 2200A RE-A2202 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1424 EV-A2216 DGA-12221-02 2200A RE-A2202 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1425 EV-A2217 DGA-12221-02 2200A RE-A2202 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1426 EV-B2211 DGA-12221-02 2200B RE-B2201 DHA Feed EV Automatic Valve DHA Liquid 17.55 m3/h 13.5 m3/h 4.05 m3/h 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1427 EV-B2212 DGA-12221-02 2200B RE-B2201 C1 Feed EV Automatic Valve C1 Gas 4614.87 Nm3/h 3549.9 Nm3/h 1064.97 Nm3/h 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1428 EV-B2213 DGA-12221-02 2200B RE-B2202 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1429 EV-B2214 DGA-12221-02 2200B RE-B2202 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1430 EV-B2215 DGA-12221-02 2200B RE-B2202 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1431 EV-B2216 DGA-12221-02 2200B RE-B2202 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1432 EV-B2217 DGA-12221-02 2200B RE-B2202 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1433 FG-A2211 DGA-12221-02 2200A RE-A2202 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
51 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1434 FG-A2212 DGA-12221-02 2200A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1435 FG-A2213 DGA-12221-02 2200A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1436 FG-A2214 DGA-12221-02 2200A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1437 FG-B2211 DGA-12221-02 2200B RE-B2202 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1438 FG-B2212 DGA-12221-02 2200B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1439 FG-B2213 DGA-12221-02 2200B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1440 FG-B2214 DGA-12221-02 2200B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1441 FIC-A2211 DGA-12221-02 2200A HE-A2202/1,2 S4 Feed Flow Flowmeter S4 Vapor 364 kg/h 280.0 kg/h 84 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1443 FIC-B2211 DGA-12221-02 2200B HE-B2202/1,2 S4 Feed Flow Flowmeter S4 Vapor 364 kg/h 280.0 kg/h 84 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1449 PG-A2211 DGA-12221-02 2200A RE-A2201 DHA Feed Press. Pressure gauge DHA Liquid 17.55 m3/h 13.5 m3/h 4.05 m3/h 4.00 kgf/cm2G 3.20 kgf/cm2G 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1450 PG-A2212 DGA-12221-02 2200A RE-A2202 C1 Outlet Press. Pressure gauge C1 Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1451 PG-A2213 DGA-12221-02 2200A HE-A2202/1,2 S4 Feed Press. Pressure gauge S4 Vapor 364 kg/h 280.0 kg/h 84 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1452 PG-A2214 DGA-12221-02 2200A HE-A2202/1,2 S4 Feed Press. Pressure gauge S4 Vapor 364 kg/h 280.0 kg/h 84 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1453 PG-B2211 DGA-12221-02 2200B RE-B2201 DHA Feed Press. Pressure gauge DHA Liquid 17.55 m3/h 13.5 m3/h 4.05 m3/h 4.00 kgf/cm2G 3.20 kgf/cm2G 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1454 PG-B2212 DGA-12221-02 2200B RE-B2202 C1 Outlet Press. Pressure gauge C1 Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1455 PG-B2213 DGA-12221-02 2200B HE-B2202/1,2 S4 Feed Press. Pressure gauge S4 Vapor 364 kg/h 280.0 kg/h 84 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
52 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1456 PG-B2214 DGA-12221-02 2200B HE-B2202/1,2 S4 Feed Press. Pressure gauge S4 Vapor 364 kg/h 280.0 kg/h 84 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1457 PI-A2214 DGA-12221-02 2200A EG Line Press. Pressure transmitter EG Vapor 8540.09 Nm3/h 6569.3 Nm3/h 1970.79 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 140.0 deg C 120.0 deg C 1.4 kg/Nm3 0.014 cP
1458 PI-B2214 DGA-12221-02 2200B EG Line Press. Pressure transmitter EG Vapor 8540.09 Nm3/h 6569.3 Nm3/h 1970.79 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 140.0 deg C 120.0 deg C 1.4 kg/Nm3 0.014 cP
1459 PIC-A2211 DGA-12221-02 2200A RE-A2202 C1 Outlet Press. Pressure transmitter C1 Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1460 PIC-A2211V DGA-12221-02 2200A C1 Line EG Outlet Control Valve Control Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 2.18 kg/cm2 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1461 PIC-A2212 DGA-12221-02 2200A RE-A2202 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1463 PIC-A2213 DGA-12221-02 2200A RE-A2202 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1465 PIC-B2211 DGA-12221-02 2200B RE-B2202 C1 Outlet Press. Pressure transmitter C1 Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1466 PIC-B2211V DGA-12221-02 2200B C1 Line EG Outlet Control Valve Control Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 2.18 kg/cm2 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1467 PIC-B2212 DGA-12221-02 2200B RE-B2202 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1469 PIC-B2213 DGA-12221-02 2200B RE-B2202 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 120.0 deg C 1012.0 kg/m3 0.299 cP
1471 SV-A2211 DGA-12221-02 2200A DHA Line EG Outlet SV Automatic Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G - 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1472 SV-A2212 DGA-12221-02 2200A DHA Line EG Outlet SV Automatic Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G - 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1473 SV-A2213 DGA-12221-02 2200A C1 Line EG Outlet SV Automatic Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G - 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1474 SV-A2214 DGA-12221-02 2200A RE-A2202 CA Feed SV Automatic Valve CA Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G - 60.0 deg C 30.0 deg C 7.9 kg/m3 0.018 cP
1475 SV-B2211 DGA-12221-02 2200B DHA Line EG Outlet SV Automatic Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G - 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1476 SV-B2212 DGA-12221-02 2200B DHA Line EG Outlet SV Automatic Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G - 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
1477 SV-B2213 DGA-12221-02 2200B C1 Line EG Outlet SV Automatic Valve EG Vapor 5074.16 Nm3/h 3903.2 Nm3/h 1170.96 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G - 150.0 deg C 120.0 deg C 1.4 kg/Nm3 0.226 cP
53 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1478 SV-B2214 DGA-12221-02 2200B RE-B2202 CA Feed SV Automatic Valve CA Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G - 60.0 deg C 30.0 deg C 7.9 kg/m3 0.018 cP
1491 EV-B2201 DGA-12222-01 2200B RE-B2201 CHA Feed EV Automatic Valve CHA Liquid/Gas 24063 kg/h 18510.0 kg/h 5553 kg/h 10.00 kgf/cm2G 7.97 kgf/cm2G - 120.0 deg C 100.0 deg C 1090.0 kg/m3 0.516 cP
1492 EV-B2202 DGA-12222-01 2200B RE-B2201 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1493 EV-B2203 DGA-12222-01 2200B RE-B2201 DHA Feed EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1494 EV-B2204 DGA-12222-01 2200B RE-B2201 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1495 EV-B2205 DGA-12222-01 2200B RE-B2201 DHA Outlet EV Automatic Valve DHA Liquid 17.55 m3/h 13.5 m3/h 4.05 m3/h 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1496 EV-B2206 DGA-12222-01 2200B RE-B2201 DHA Outlet EV Automatic Valve DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1497 EV-B2207 DGA-12222-01 2200B HE-B2201/1,2 S4 Feed EV Automatic Valve S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1498 FG-B2201 DGA-12222-01 2200B RE-B2201 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1499 FG-B2202 DGA-12222-01 2200B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1500 FG-B2203 DGA-12222-01 2200B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1501 FG-B2204 DGA-12222-01 2200B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1502 FG-B2205 DGA-12222-01 2200B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1503 FIC-B2201 DGA-12222-01 2200B HE-B2201/1,2 S4 Feed Flow Flowmeter S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1507 PG-B2201 DGA-12222-01 2200B RE-B2201 CHA Feed Press. Pressure gauge CHA Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 10.00 kgf/cm2G 7.97 kgf/cm2G 120.0 deg C 100.0 deg C 1090.0 kg/m3 0.516 cP
1508 PG-B2202 DGA-12222-01 2200B RE-B2201 C1 Outlet Press. Pressure gauge C1 Gas 4614.87 Nm3/h 3549.9 Nm3/h 1064.97 Nm3/h 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1509 PG-B2203 DGA-12222-01 2200B HE-B2201/1,2 S4 Feed Press. Pressure gauge S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1510 PG-B2204 DGA-12222-01 2200B HE-B2201/1,2 S4 Feed Press. Pressure gauge S4 Vapor 4888 kg/h 3760.0 kg/h 1128 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1511 PIC-B2201 DGA-12222-01 2200B RE-B2201 C1 Outlet Press. Pressure transmitter C1 Gas 4614.87 Nm3/h 3549.9 Nm3/h 1064.97 Nm3/h 4.00 kgf/cm2G 2.70 kgf/cm2G 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
54 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1512 PIC-B2201V/B DGA-12222-01 2200B C1 Line EG Outlet Control Valve Control Valve EG Vapor 4.00 kgf/cm2G 2.70 kgf/cm2G 2.68 kg/cm2 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1513 PIC-B2202 DGA-12222-01 2200B RE-B2201 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1515 PIC-B2203 DGA-12222-01 2200B RE-B2201 DHA Feed Press. Pressure transmitter DHA Liquid - - - 4.00 kgf/cm2G 3.20 kgf/cm2G 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1517 SV-B2201 DGA-12222-01 2200B CHA Line MeOH Feed SV Automatic Valve MeOH Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G - 120.0 deg C 70.0 deg C 730.0 kg/m3 0.307 cP
1518 SV-B2202 DGA-12222-01 2200B CHA Line MeOH Feed SV Automatic Valve MeOH Vapor 2008.63 Nm3/h 1545.1 Nm3/h 463.53 Nm3/h 10.00 kgf/cm2G 7.62 kgf/cm2G - 120.0 deg C 106.0 deg C 1.4 kg/Nm3 0.012 cP
1519 SV-B2203 DGA-12222-01 2200B DHA Line EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1520 SV-B2204 DGA-12222-01 2200B DHA Line EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 3.20 kgf/cm2G - 150.0 deg C 125.0 deg C 1008.0 kg/m3 0.296 cP
1521 SV-B2205 DGA-12222-01 2200B C1 Line EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 2.70 kgf/cm2G - 150.0 deg C 125.0 deg C 1.4 kg/Nm3 0.014 cP
1522 SV-B2206 DGA-12222-01 2200B RE-B2201 CA Feed SV Automatic Valve CA Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 10.00 kgf/cm2G 6.00 kgf/cm2G - 60.0 deg C 30.0 deg C 7.9 kg/m3 0.018 cP
1528 LG-2251 DGA-12223-01 2200 TK-2251 DHA Level Level gauge DHA Liquid - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1129.1 kg/m3 1.151 cP
1529 LI-2251 DGA-12223-01 2200 TK-2251 DHA Level Differential press. Transmitter
DHA Liquid - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1129.1 kg/m3 1.151 cP
1530 PG-2251A DGA-12223-01 2200 PU-2251/A Discharge Press. Pressure gauge DHA Liquid 13 m3/h 10.0 m3/h 3.00 kgf/cm2G 1.50 kgf/cm2G 70.0 deg C 50.0 deg C 1129.1 kg/m3 1.151 cP
1531 PG-2251B DGA-12223-01 2200 PU-2251/A Discharge Press. Pressure gauge DHA Liquid 13 m3/h 10.0 m3/h 3.00 kgf/cm2G 1.50 kgf/cm2G 70.0 deg C 50.0 deg C 1129.1 kg/m3 1.151 cP
1532 PG-2252 DGA-12223-01 2200 PU-2252 Discharge Press. Pressure gauge DHA Liquid 26 m3/h 20.0 m3/h 6.00 kgf/cm2G 4.60 kgf/cm2G 70.0 deg C 50.0 deg C 1129.1 kg/m3 1.151 cP
1534 EV-A2301 DGA-12321-01 2300A HE-A2301 MeOH Feed EV Automatic Valve MeOH Liquid 3.64 m3/h 2.8 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1535 FG-2352 DGA-12321-01 2300 TK-2351 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1536 FG-A2301 DGA-12321-01 2300A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1537 FG-A2302 DGA-12321-01 2300A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1538 FG-A2303 DGA-12321-01 2300A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1539 FG-A2304 DGA-12321-01 2300A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
55 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1540 FG-A2351 DGA-12321-01 2300A HE-A2301 SC Feed Flow Area Flowmeter SC Liquid 4290 kg/h 3300.0 kg/h 5.00 kgf/cm2G 3.81 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1541 FG-B2351 DGA-12321-01 2300B HE-B2301 SC Feed Flow Area Flowmeter SC Liquid 4290 kg/h 3300.0 kg/h 5.00 kgf/cm2G 3.81 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1542 FICQ-A2301 DGA-12321-01 2300A HE-A2301 MeOH Feed Flow Flowmeter MeOH Liquid 3.64 m3/h 2.8 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1544 LG-2351 DGA-12321-01 2300 TK-2351 SC Level Level gauge SC Liquid - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1545 LG-A2301 DGA-12321-01 2300A HE-A2302/1 MeOH Level Level gauge MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
1546 LG-A2302 DGA-12321-01 2300A HE-A2302/2 MeOH Level Level gauge MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
1547 LG-A2303 DGA-12321-01 2300A VE-A2301 DHA Level Level gauge DHA Liquid - - 4.00 kgf/cm2G 2.20 kgf/cm2G 120.0 deg C 109.0 deg C 995.0 kg/m3 0.298 cP
1548 LG-A2304 DGA-12321-01 2300A VE-A2302 DHA Level Level gauge DHA Liquid - - 4.00 kgf/cm2G 2.10 kgf/cm2G 110.0 deg C 98.0 deg C 973.0 kg/m3 0.297 cP
1549 LI-A2301 DGA-12321-01 2300A HE-A2302/1 MeOH Level Differential press. Transmitter
MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
1550 LI-A2302 DGA-12321-01 2300A HE-A2302/2 MeOH Level Differential press. Transmitter
MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
1551 LIC-2351 DGA-12321-01 2300 TK-2351 SC Level Liquid level TransmitterSC Liquid - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1552 LIC-2351V DGA-12321-01 2300 TK-3011 SC Feed Control Valve Control Valve SC Liquid 14807 kg/h 11390.0 kg/h 5.00 kgf/cm2G 3.81 kgf/cm2G 0.5 kg/cm2 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1553 PG-2351A DGA-12321-01 2300 PU-2351/A Discharge Press. Pressure gauge SC Liquid 26 m3/h 20.0 m3/h 5.00 kgf/cm2G 3.81 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1554 PG-2351B DGA-12321-01 2300 PU-2351/B Discharge Press. Pressure gauge SC Liquid 26 m3/h 20.0 m3/h 5.00 kgf/cm2G 3.81 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1555 PG-A2301 DGA-12321-01 2300A VE-A2301 C1 Outlet Press. Pressure gauge C1 Vapor 3439.54 Nm3/h 2645.8 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 120.0 deg C 109.0 deg C 1.7 kg/Nm3 0.014 cP
1556 PG-A2302 DGA-12321-01 2300A VE-A2302 C1 Outlet Press. Pressure gauge C1 Vapor 4.00 kgf/cm2G 2.10 kgf/cm2G 110.0 deg C 98.0 deg C 1.8 kg/Nm3 0.014 cP
1558 QI-2351 DGA-12321-01 2300 PU-2351/A,B Discharge pH pH Meter SC Liquid 26 m3/h 20.0 m3/h 5.00 kgf/cm2G 3.81 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1565 FG-A2305 DGA-12321-02 2300A C1 Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1566 FI-A2302 DGA-12321-02 2300A VE-A2305 DHA Feed Flow Flowmeter DHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 9.00 kgf/cm2G 6.85 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1567 LG-A2305 DGA-12321-02 2300A VE-A2303 C1 Level Level gauge C1 Liquid - - - 4.00 kgf/cm2G 2.10 kgf/cm2G 60.0 deg C 40.0 deg C 986.0 kg/m3 0.6 cP
56 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1568 LG-A2306 DGA-12321-02 2300A VE-A2304 C1 Level Level gauge C1 Liquid - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 15.0 deg C 982.0 kg/m3 0.898 cP
1569 LG-A2307 DGA-12321-02 2300A VE-A2305 DHA Level Level gauge DHA Liquid - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1570 LIC-A2303 DGA-12321-02 2300A VE-A2305 DHA Level Differential press. Transmitter
DHA Liquid - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1572 PG-A2303 DGA-12321-02 2300A VE-A2303 C1 Feed Press. Pressure gauge C1 Gas 2037.23 Nm3/h 1567.1 Nm3/h 470.13 Nm3/h 4.00 kgf/cm2G 2.10 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.012 cP
1573 PG-A2304 DGA-12321-02 2300A VE-A2304 C1 Feed Press. Pressure gauge C1 Gas 1999.14 Nm3/h 1537.8 Nm3/h 461.34 Nm3/h 4.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1574 PG-A2305A DGA-12321-02 2300A PU-A2301/A Discharge Press. Pressure gauge DHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 9.00 kgf/cm2G 6.85 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1575 PG-A2305B DGA-12321-02 2300A PU-A2301/B Discharge Press. Pressure gauge DHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 9.00 kgf/cm2G 6.85 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1577 PIC-A2302 DGA-12321-02 2300A VE-A2303 C1 Outlet Press. Pressure transmitter C1 Gas - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1579 SV-A2301 DGA-12321-02 2300A VE-A2303 EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1580 SV-A2302 DGA-12321-02 2300A VE-A2303 C1 Outlet SV Automatic Valve C1 Vapor 1999.14 Nm3/h 1537.8 Nm3/h 461.34 Nm3/h 4.00 kgf/cm2G 1.70 kgf/cm2G - 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1584 EV-B2301 DGA-12322-01 2300B HE-B2301 MeOH Feed EV Automatic Valve MeOH Liquid 3.64 m3/h 2.8 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1585 FG-B2301 DGA-12322-01 2300B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1586 FG-B2302 DGA-12322-01 2300B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1587 FG-B2303 DGA-12322-01 2300B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1588 FG-B2304 DGA-12322-01 2300B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1589 FICQ-B2301 DGA-12322-01 2300B HE-B2301 MeOH Feed Flow Flowmeter MeOH Liquid 3.64 m3/h 2.8 m3/h 10.00 kgf/cm2G 7.62 kgf/cm2G 60.0 deg C 30.0 deg C 779.0 kg/m3 0.503 cP
1591 LG-B2301 DGA-12322-01 2300B HE-B2302/1 MeOH Level Level gauge MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
1592 LG-B2302 DGA-12322-01 2300B HE-B2302/2 MeOH Level Level gauge MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
57 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1593 LG-B2303 DGA-12322-01 2300B VE-B2301 DHA Level Level gauge DHA Liquid - - 4.00 kgf/cm2G 2.20 kgf/cm2G 120.0 deg C 109.0 deg C 995.0 kg/m3 0.298 cP
1594 LG-B2304 DGA-12322-01 2300B VE-B2302 DHA Level Level gauge DHA Liquid - - 4.00 kgf/cm2G 2.10 kgf/cm2G 110.0 deg C 98.0 deg C 973.0 kg/m3 0.297 cP
1595 LI-B2301 DGA-12322-01 2300B HE-B2302/1 MeOH Level Differential press. Transmitter
MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
1596 LI-B2302 DGA-12322-01 2300B HE-B2302/2 MeOH Level Differential press. Transmitter
MeOH Liquid - - 10.00 kgf/cm2G 7.62 kgf/cm2G 120.0 deg C 106.0 deg C 730.0 kg/m3 0.307 cP
1597 PG-B2301 DGA-12322-01 2300B VE-B2301 C1 Outlet Press. Pressure gauge C1 Vapor 3439.54 Nm3/h 2645.8 Nm3/h 4.00 kgf/cm2G 2.20 kgf/cm2G 120.0 deg C 109.0 deg C 1.7 kg/Nm3 0.014 cP
1598 PG-B2302 DGA-12322-01 2300B VE-B2302 C1 Outlet Press. Pressure gauge C1 Vapor 4.00 kgf/cm2G 2.10 kgf/cm2G 110.0 deg C 98.0 deg C 1.8 kg/Nm3 0.014 cP
1606 FG-B2305 DGA-12322-02 2300B C1 Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1607 FI-B2302 DGA-12322-02 2300B VE-B2305 DHA Feed Flow Flowmeter DHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 9.00 kgf/cm2G 6.85 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1608 LG-B2305 DGA-12322-02 2300B VE-B2303 C1 Level Level gauge C1 Liquid - - - 4.00 kgf/cm2G 2.10 kgf/cm2G 60.0 deg C 40.0 deg C 986.0 kg/m3 0.6 cP
1609 LG-B2306 DGA-12322-02 2300B VE-B2304 C1 Level Level gauge C1 Liquid - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 15.0 deg C 982.0 kg/m3 0.898 cP
1610 LG-B2307 DGA-12322-02 2300B VE-B2305 DHA Level Level gauge DHA Liquid - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1611 LIC-B2303 DGA-12322-02 2300B VE-B2305 DHA Level Differential press. Transmitter
DHA Liquid - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1613 PG-B2303 DGA-12322-02 2300B VE-B2303 C1 Feed Press. Pressure gauge C1 Gas 2037.23 Nm3/h 1567.1 Nm3/h 470.13 Nm3/h 4.00 kgf/cm2G 2.10 kgf/cm2G 60.0 deg C 40.0 deg C 2.2 kg/Nm3 0.012 cP
1614 PG-B2304 DGA-12322-02 2300B VE-B2304 C1 Feed Press. Pressure gauge C1 Gas 1999.14 Nm3/h 1537.8 Nm3/h 461.34 Nm3/h 4.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1615 PG-B2305A DGA-12322-02 2300B PU-B2301/A Discharge Press. Pressure gauge DHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 9.00 kgf/cm2G 6.85 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1616 PG-B2305B DGA-12322-02 2300B PU-B2301/B Discharge Press. Pressure gauge DHA Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 9.00 kgf/cm2G 6.85 kgf/cm2G 100.0 deg C 88.8 deg C 990.0 kg/m3 0.346 cP
1618 PIC-B2302 DGA-12322-02 2300B VE-B2303 C1 Outlet Press. Pressure transmitter C1 Gas - - - 4.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1620 SV-B2301 DGA-12322-02 2300B VE-B2303 EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 2.00 kgf/cm2G - 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
58 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1621 SV-B2302 DGA-12322-02 2300B VE-B2303 C1 Outlet SV Automatic Valve C1 Vapor 1999.14 Nm3/h 1537.8 Nm3/h 461.34 Nm3/h 4.00 kgf/cm2G 1.70 kgf/cm2G - 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1625 FG-2401 DGA-12420-01 2400 CL-2402 DW Feed Flow Area Flowmeter DW Liquid 0.13 m3/h 0.1 m3/h 0.03 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1626 FG-2402 DGA-12420-01 2400 CL-2403 CS Feed Flow Area Flowmeter CS Liquid 52 kg/h 40.0 kg/h 12 kg/h 7.00 kgf/cm2G 5.14 kgf/cm2G 60.0 deg C 30.0 deg C 1269.0 kg/m3 4.541 cP
1627 FI-2401 DGA-12420-01 2400 HE-2402 DHA Feed Flow Flowmeter DHA Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 6.00 kgf/cm2G 4.48 kgf/cm2G 60.0 deg C 7.8 deg C 1067.0 kg/m3 1.379 cP
1628 FI-2402 DGA-12420-01 2400 CL-2402 WCS Feed Flow Flowmeter WCS Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 7.0 deg C 1087.0 kg/m3 1.762 cP
1629 FI-2403 DGA-12420-01 2400 HE-2403 CS Feed Flow Flowmeter CS Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 6.00 kgf/cm2G 4.63 kgf/cm2G 60.0 deg C 5.1 deg C 1275.0 kg/m3 7.142 cP
1630 LG-2401 DGA-12420-01 2400 CL-2401 C1 Level Level gauge C1 Liquid - - - 4.00 kgf/cm2G 1.70 kgf/cm2G 60.0 deg C 7.8 deg C 1067.0 kg/m3 1.379 cP
1631 LG-2402 DGA-12420-01 2400 CL-2402 C1 Level Level gauge C1 Liquid - - - 4.00 kgf/cm2G 1.65 kgf/cm2G 60.0 deg C 7.0 deg C 1087.0 kg/m3 1.762 cP
1632 LG-2403 DGA-12420-01 2400 CL-2403 CS Level Level gauge CS Liquid - - - 4.00 kgf/cm2G 1.60 kgf/cm2G 60.0 deg C 5.1 deg C 1275.0 kg/m3 7.142 cP
1639 PG-2401 DGA-12420-01 2400 CL-2401 C1 Feed Press. Pressure gauge C1 Gas 1999.14 Nm3/h 1537.8 Nm3/h 461.34 Nm3/h 4.00 kgf/cm2G 2.00 kgf/cm2G 60.0 deg C 15.0 deg C 2.2 kg/Nm3 0.011 cP
1640 PG-2402 DGA-12420-01 2400 CL-2401 C1 Outlet Press. Pressure gauge C1 Gas 3987.62 Nm3/h 3067.4 Nm3/h 920.22 Nm3/h 4.00 kgf/cm2G 1.70 kgf/cm2G 60.0 deg C 7.0 deg C 2.3 kg/Nm3 0.01 cP
1641 PG-2403A DGA-12420-01 2400 PU-2401/A Discharge Press. Pressure gauge DHA Liquid 21.97 m3/h 16.9 m3/h 5.07 m3/h 6.00 kgf/cm2G 4.48 kgf/cm2G 60.0 deg C 7.8 deg C 1067.0 kg/m3 1.379 cP
1642 PG-2403B DGA-12420-01 2400 PU-2401/B Discharge Press. Pressure gauge DHA Liquid 21.97 m3/h 16.9 m3/h 5.07 m3/h 6.00 kgf/cm2G 4.48 kgf/cm2G 60.0 deg C 7.8 deg C 1067.0 kg/m3 1.379 cP
1643 PG-2404 DGA-12420-01 2400 CL-2402 C1 Outlet Press. Pressure gauge C1 Gas 3986.97 Nm3/h 3066.9 Nm3/h 920.07 Nm3/h 4.00 kgf/cm2G 1.70 kgf/cm2G 60.0 deg C 7.0 deg C 2.3 kg/Nm3 0.01 cP
1644 PG-2405A DGA-12420-01 2400 PU-2402/A Discharge Press. Pressure gauge CS Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 7.0 deg C 1087.0 kg/m3 1.762 cP
1645 PG-2405B DGA-12420-01 2400 PU-2402/B Discharge Press. Pressure gauge CS Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 7.0 deg C 1087.0 kg/m3 1.762 cP
59 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1646 PG-2406 DGA-12420-01 2400 CL-2403 C1 Feed Press. Pressure gauge C1 Gas 3984.24 Nm3/h 3064.8 Nm3/h 919.44 Nm3/h 4.00 kgf/cm2G 1.60 kgf/cm2G 60.0 deg C 5.0 deg C 2.3 kg/Nm3 0.01 cP
1647 PG-2407A DGA-12420-01 2400 PU-2403/A Discharge Press. Pressure gauge CS Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 6.00 kgf/cm2G 4.63 kgf/cm2G 60.0 deg C 5.1 deg C 1275.0 kg/m3 7.142 cP
1648 PG-2407B DGA-12420-01 2400 PU-2403/B Discharge Press. Pressure gauge CS Liquid 19.5 m3/h 15.0 m3/h 4.5 m3/h 6.00 kgf/cm2G 4.63 kgf/cm2G 60.0 deg C 5.1 deg C 1275.0 kg/m3 7.142 cP
1649 SV-2401 DGA-12420-01 2400 CL-2402 DW Outlet SV Automatic Valve DW Liquid 0.13 m3/h 0.1 m3/h 0.03 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 35.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1650 SV-2402 DGA-12420-01 2400 CL-2403 CS Outlet SV Automatic Valve CS Liquid 52 kg/h 40.0 kg/h 12 kg/h 7.00 kgf/cm2G 5.14 kgf/cm2G - 60.0 deg C 30.0 deg C 1269.0 kg/m3 4.541 cP
1651 SV-2403 DGA-12420-01 2400 CL-2402 CS Outlet SV Automatic Valve WCS Liquid 0.156 m3/h 0.1 m3/h 0.036 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G - 60.0 deg C 7.0 deg C 1087.0 kg/m3 1.762 cP
1662 EV-A2401 DGA-12420-02 2400 MX-A1101/1,2 C1 Feed EV Automatic Valve C1 Gas 1815.97 Nm3/h 1396.9 Nm3/h 419.07 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G - 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1663 EV-B2401 DGA-12420-02 2400 MX-B1101/1,2 C1 Feed EV Automatic Valve C1 Gas 1815.97 Nm3/h 1396.9 Nm3/h 419.07 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G - 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1664 FG-2403 DGA-12420-02 2400 CL-2404 SA Feed Flow Area Flowmeter SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 7.00 kgf/cm2G 4.92 kgf/cm2G 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
1665 FG-2404 DGA-12420-02 2400 EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1666 FI-2404 DGA-12420-02 2400 CL-2404 SA Feed Flow Flowmeter SA Liquid 20.8 m3/h 16.0 m3/h 4.8 m3/h 7.00 kgf/cm2G 4.92 kgf/cm2G 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
1667 FI-2405 DGA-12420-02 2400 CL-2405 SA Feed Flow Flowmeter SA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 7.00 kgf/cm2G 5.17 kgf/cm2G 60.0 deg C 40.0 deg C 1808.0 kg/m3 16.265 cP
1668 FI-2406 DGA-12420-02 2400 CL-2406 SA Feed Flow Flowmeter SA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 7.00 kgf/cm2G 4.62 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.048 cP
1669 FI-2407 DGA-12420-02 2400 CL-2406 SA Feed Flow Flowmeter SA Liquid 0.104 m3/h 0.1 m3/h 0.024 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G 60.0 deg C 30.0 deg C 1820.0 kg/m3 21.61 cP
1670 FICQ-A2408 DGA-12420-02 2400 MX-A1101/1,2 C1 Feed Flow Flowmeter C1 Gas 1815.97 Nm3/h 1396.9 Nm3/h 419.07 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1672 FICQ-B2408 DGA-12420-02 2400 MX-B1101/1,2 C1 Feed Flow Flowmeter C1 Gas 1815.97 Nm3/h 1396.9 Nm3/h 419.07 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1674 LG-2404 DGA-12420-02 2400 CL-2404 SA Level Level gauge SA Liquid - - - 4.00 kgf/cm2G 1.60 kgf/cm2G 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
1675 LG-2405 DGA-12420-02 2400 CL-2405 SA Level Level gauge SA Liquid - - - 4.00 kgf/cm2G 1.55 kgf/cm2G 60.0 deg C 40.0 deg C 1808.0 kg/m3 16.265 cP
1676 LG-2406 DGA-12420-02 2400 CL-2406 SA Level Level gauge SA Liquid - - - 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.048 cP
1677 LG-2407 DGA-12420-02 2400 TS-2401 SA Level Level gauge SA Liquid - - - F.L ATM 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
60 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1678 LG-2408 DGA-12420-02 2400 FL-2401 SA Level Level gauge SA Liquid - - - 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.048 cP
1684 PdG-2414 DGA-12420-02 2400 FL-2401 C1 Differential Press. Differential press. Gauge
C1 Gas 3962.27 Nm3/h 3047.9 Nm3/h 914.37 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1685 PG-2408 DGA-12420-02 2400 CL-2404 C1 Feed Press. Pressure gauge C1 Gas 3963.05 Nm3/h 3048.5 Nm3/h 914.55 Nm3/h 4.00 kgf/cm2G 1.60 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1686 PG-2409A DGA-12420-02 2400 PU-2404/A Discharge Press. Pressure gauge SA Liquid 20.8 m3/h 16.0 m3/h 4.8 m3/h 7.00 kgf/cm2G 4.92 kgf/cm2G 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
1687 PG-2409B DGA-12420-02 2400 PU-2404/B Discharge Press. Pressure gauge SA Liquid 20.8 m3/h 16.0 m3/h 4.8 m3/h 7.00 kgf/cm2G 4.92 kgf/cm2G 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
1688 PG-2410 DGA-12420-02 2400 CL-2406 C1 Feed Press. Pressure gauge C1 Gas 3962.27 Nm3/h 3047.9 Nm3/h 914.37 Nm3/h 4.00 kgf/cm2G 1.55 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1689 PG-2411A DGA-12420-02 2400 PU-2405/A Discharge Press. Pressure gauge SA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 7.00 kgf/cm2G 5.17 kgf/cm2G 60.0 deg C 40.0 deg C 1808.0 kg/m3 16.265 cP
1690 PG-2411B DGA-12420-02 2400 PU-2405/B Discharge Press. Pressure gauge SA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 7.00 kgf/cm2G 5.17 kgf/cm2G 60.0 deg C 40.0 deg C 1808.0 kg/m3 16.265 cP
1691 PG-2412 DGA-12420-02 2400 CL-2406 C1 Feed Press. Pressure gauge C1 Gas 3962.27 Nm3/h 3047.9 Nm3/h 914.37 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1692 PG-2413A DGA-12420-02 2400 PU-2406/A Discharge Press. Pressure gauge SA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 7.00 kgf/cm2G 4.62 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.048 cP
1693 PG-2413B DGA-12420-02 2400 PU-2406/B Discharge Press. Pressure gauge SA Liquid 19.76 m3/h 15.2 m3/h 4.56 m3/h 7.00 kgf/cm2G 4.62 kgf/cm2G 60.0 deg C 40.0 deg C 1806.0 kg/m3 16.048 cP
1694 PG-A2415 DGA-12420-02 2400 MX-A1101/1,2 C1 Feed Press. Pressure gauge C1 Gas 1815.97 Nm3/h 1396.9 Nm3/h 419.07 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1695 PG-B2415 DGA-12420-02 2400 MX-B1101/1,2 C1 Feed Press. Pressure gauge C1 Gas 1815.97 Nm3/h 1396.9 Nm3/h 419.07 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1696 PIC-2401 DGA-12420-02 2400 FL-2401 C1 Outlet Press. Pressure transmitter C1 Gas 3962.27 Nm3/h 3047.9 Nm3/h 914.37 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1697 PIC-2401V/B DGA-12420-02 2400 FL-2401 EG Outlet Control Valve Control Valve EG Vapor 4.00 kgf/cm2G 1.50 kgf/cm2G 0.5 kg/cm2 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1698 QIC-2401 DGA-12420-02 2400 CL-2404 SA Density Densitometer SA Liquid 7.00 kgf/cm2G 4.92 kgf/cm2G 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
61 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1700 SV-2404 DGA-12420-02 2400 CL-2406 SA Feed SV Automatic Valve SA Liquid 0.104 m3/h 0.1 m3/h 0.024 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G - 60.0 deg C 30.0 deg C 1820.0 kg/m3 21.61 cP
1701 SV-2405 DGA-12420-02 2400 CL-2404 WSA Outlet SV Automatic Valve WSA Liquid 0.156 m3/h 0.1 m3/h 0.036 m3/h 7.00 kgf/cm2G 4.92 kgf/cm2G - 60.0 deg C 40.9 deg C 1558.0 kg/m3 6.733 cP
1702 SV-2406 DGA-12420-02 2400 FL-2401 EG Outlet SV Automatic Valve EG Vapor 4.00 kgf/cm2G 1.50 kgf/cm2G - 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1707 FG-2451 DGA-12420-03 2400 HE-2452 CS Feed Flow Area Flowmeter CS Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.32 kgf/cm2G 90.0 deg C 65.0 deg C 1193.9 kg/m3 1.681 cP
1708 FIC-2451 DGA-12420-03 2400 CL-2451 CS Feed Flow Flowmeter CS Liquid 7.00 kgf/cm2G 5.14 kgf/cm2G 60.0 deg C 35.0 deg C 1267.2 kg/m3 4.181 cP
1709 FIC-2451V DGA-12420-03 2400 CL-2451 CS Feed Control Valve Control Valve CS Liquid 7.00 kgf/cm2G 5.14 kgf/cm2G 0.5 kg/cm2 60.0 deg C 35.0 deg C 1267.2 kg/m3 4.181 cP
1710 FIC-2452 DGA-12420-03 2400 CL-2451 SC Feed Flow Flowmeter SC Liquid 0 m3/h 0.0 m3/h 0 m3/h 5.00 kgf/cm2G 3.81 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1711 FIC-2452V DGA-12420-03 2400 CL-2451 SC Feed Control Valve Control Valve SC Liquid 0 kg/h 0.0 kg/h 0 kg/h 5.00 kgf/cm2G 3.81 kgf/cm2G 0.5 kg/cm2 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
1712 LG-2451 DGA-12420-03 2400 CL-2451 EG Level Level gauge CS Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 80.0 deg C 65.0 deg C 1193.9 kg/m3 1.681 cP
1714 PG-2451A DGA-12420-03 2400 PU-2451/A Discharge Press. Pressure gauge CS Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.32 kgf/cm2G 90.0 deg C 65.0 deg C 1193.9 kg/m3 1.681 cP
1715 PG-2451B DGA-12420-03 2400 PU-2451/B Discharge Press. Pressure gauge CS Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.32 kgf/cm2G 90.0 deg C 65.0 deg C 1193.9 kg/m3 1.681 cP
1716 QI-2451 DGA-12420-03 2400 CL-2451 CS Outlet pH pH Meter CS Liquid 5.00 kgf/cm2G 3.32 kgf/cm2G 90.0 deg C 55.0 deg C 1193.9 kg/m3 1.681 cP
1717 SV-2453 DGA-12420-03 2400 CL-2451 Top S4 Feed SV Automatic Valve S4 Vapor 0 kg/h 0.0 kg/h 0 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1718 SV-2454 DGA-12420-03 2400 CL-2451 Top N3 Feed SV Automatic Valve N3 Gas 0 Nm3/h 0.0 Nm3/h 0 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1719 SV-A2451 DGA-12420-03 2400 HE-2451/1 PW Feed SV Automatic Valve PW Liquid 0 m3/h 0.0 m3/h 0 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1720 SV-B2451 DGA-12420-03 2400 HE-2451/2 PW Feed SV Automatic Valve PW Liquid 0 m3/h 0.0 m3/h 0 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G - 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1725 TIC-2452V DGA-12420-03 2400 HE-2452 CW Feed Control Valve Control Valve CW Liquid 71.5 m3/h 55.0 m3/h 16.5 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 0.5 kg/cm2 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1730 EV-2501 DGA-12520-01 2500 HE-2501 C1 Outlet EV Automatic Valve C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1731 EV-2502 DGA-12520-01 2500 TK-2502 C1 Outlet EV Automatic Valve C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
62 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1732 EV-2503 DGA-12520-01 2500 TK-2502 C1 Outlet EV Automatic Valve C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1733 EV-2504 DGA-12520-01 2500 PU-2502/A,B C1 Discharge EV Automatic Valve C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 15.00 kgf/cm2G 11.77 kgf/cm2G - 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1734 FI-2501 DGA-12520-01 2500 HE-2501 C1 Feed Flow Flowmeter C1 Gas 332.8 Nm3/h 256.0 Nm3/h 76.8 Nm3/h 10.00 kgf/cm2G 8.50 kgf/cm2G 140.0 deg C 120.0 deg C 2.3 kg/Nm3 0.014 cP
1735 FIC-2502 DGA-12520-01 2500 PU-2502/A,B C1 Discharge Flow Flowmeter C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 15.00 kgf/cm2G 11.77 kgf/cm2G 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
PU-2502/A,B C1 Discharge
1736 FIC-2502V DGA-12520-01 2500 Control Valve C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 15.00 kgf/cm2G 11.77 kgf/cm2G 0.5 kg/cm2 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
Control Valve
1737 FIC-2503 DGA-12520-01 2500 TK-2502 C1 Outlet Flow Flowmeter C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1738 FIC-2503V DGA-12520-01 2500 TK-2502 C1 Outlet Control Valve Control Valve C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 10.00 kgf/cm2G 8.50 kgf/cm2G 7 kg/cm2 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1739 LG-2502 DGA-12520-01 2500 TK-2502 C1 Level Level gauge C1 Liquid - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1741 PdG-2501 DGA-12520-01 2500 FL-2501/A C1 Differential Press. Differential press. Gauge
C1 Gas 1300 Nm3/h 1000.0 Nm3/h 300 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1742 PdG-2502 DGA-12520-01 2500 FL-2501/B C1 Differential Press. Differential press. Gauge
C1 Gas 1300 Nm3/h 1000.0 Nm3/h 300 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1743 PG-2503 DGA-12520-01 2500 FL-2501/1 C1 Outlet Press. Pressure gauge C1 Gas 1300 Nm3/h 1000.0 Nm3/h 300 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1744 PG-2504 DGA-12520-01 2500 FL-2501/2 C1 Outlet Press. Pressure gauge C1 Gas 1300 Nm3/h 1000.0 Nm3/h 300 Nm3/h 4.00 kgf/cm2G 1.50 kgf/cm2G 60.0 deg C 40.0 deg C 2.3 kg/Nm3 0.012 cP
1745 PG-2505 DGA-12520-01 2500 TK-2502 C1 Press. Pressure gauge C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.9 deg C 2.3 kg/Nm3 0.014 cP
1746 PG-2506A DGA-12520-01 2500 PU-2502/A Discharge Press. Pressure gauge C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 15.00 kgf/cm2G 11.77 kgf/cm2G 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1747 PG-2506B DGA-12520-01 2500 PU-2502/B Discharge Press. Pressure gauge C1 Liquid 0.91 m3/h 0.7 m3/h 0.21 m3/h 15.00 kgf/cm2G 11.77 kgf/cm2G 60.0 deg C 41.9 deg C 875.0 kg/m3 0.143 cP
1748 PI-2502 DGA-12520-01 2500 TK-2502 C1 Press. Pressure transmitter C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.9 deg C 2.3 kg/Nm3 0.014 cP
1750 PIC-2501 DGA-12520-01 2500 HE-2501 C1 Feed Press. Pressure transmitter C1 Gas 332.8 Nm3/h 256.0 Nm3/h 76.8 Nm3/h 10.00 kgf/cm2G 8.50 kgf/cm2G 140.0 deg C 120.0 deg C 2.3 kg/Nm3 0.014 cP
1751 PIC-2501V/A DGA-12520-01 2500 HE-2501 CW Feed Control Valve Control Valve CW Liquid 32.89 m3/h 25.3 m3/h 7.59 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 0.5 kg/cm2 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1752 PIC-2501V/B DGA-12520-01 2500 HE-2501 C1 Purge Control Valve Control Valve C1 Gas 10.00 kgf/cm2G 8.50 kgf/cm2G 7 kg/cm2 60.0 deg C 41.9 deg C 2.3 kg/Nm3 0.014 cP
1756 EV-2505 DGA-12520-02 2500 VE-2552 C1 Feed EV Automatic Valve C1 Liquid 26 L/h 20.0 L/h 6 L/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
63 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1757 EV-2506 DGA-12520-02 2500 HE-2502 S2 Feed EV Automatic Valve S2 Vapor 243.1 kg/h 187.0 kg/h 56.1 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G - 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1758 EV-2508 DGA-12520-02 2500 CL-2501 C1 Outlet EV Automatic Valve C1 Liquid 0.78 m3/h 0.6 m3/h 0.18 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 874.0 kg/m3 0.144 cP
1759 EV-A2507 DGA-12520-02 2500 HE-A1802 CM Feed EV Automatic Valve CM Liquid 8.00 kgf/cm2G 5.37 kgf/cm2G - 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1760 EV-B2507 DGA-12520-02 2500 HE-B1802 CM Feed EV Automatic Valve CM Liquid 8.00 kgf/cm2G 5.37 kgf/cm2G - 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1761 FI-2504 DGA-12520-02 2500 CL-2501 C1 Feed Flow Flowmeter C1 Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 874.0 kg/m3 0.144 cP
1762 FI-2505 DGA-12520-02 2500 HE-2503 C1 Outlet Flow Flowmeter C1 Liquid 0.78 m3/h 0.6 m3/h 0.18 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 874.0 kg/m3 0.144 cP
1763 FI-2553 DGA-12520-02 2500 VE-2552 CM Outlet Flow Flowmeter CM Liquid 26 L/h 20.0 L/h 6 L/h 8.00 kgf/cm2G 5.37 kgf/cm2G 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1764 FIC-2506 DGA-12520-02 2500 HE-2502 S2 Feed Flow Flowmeter S2 Vapor 243.1 kg/h 187.0 kg/h 56.1 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1765 FIC-2506V DGA-12520-02 2500 HE-2502 S2 Feed Control Valve Control Valve S2 Vapor 243.1 kg/h 187.0 kg/h 56.1 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 0.1 kg/cm2 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1766 FIC-2507 DGA-12520-02 2500 VE-2552 C1 Feed Flow Flowmeter C1 Liquid 26 L/h 20.0 L/h 6 L/h 10.00 kgf/cm2G 8.00 kgf/cm2G 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1767 FIC-2507V DGA-12520-02 2500 VE-2552 C1 Feed Control Valve Control Valve C1 Liquid 26 L/h 20.0 L/h 6 L/h 10.00 kgf/cm2G 8.50 kgf/cm2G 7 kg/cm2 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1768 LG-2501 DGA-12520-02 2500 CL-2501 C1 Level Level gauge C1 Liquid - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1769 LG-2553 DGA-12520-02 2500 VE-2552 CM Level Level gauge CM Liquid - - - 4.00 kgf/cm2G 1.50 kgf/cm2G 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1773 LIC-2553V DGA-12520-02 2500 VE-2552 CM Feed Control Valve Control Valve CM Liquid 0.026 m3/h 0.0 m3/h 0.006 m3/h 8.00 kgf/cm2G 5.37 kgf/cm2G 0.5 kg/cm2 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1774 PG-2507 DGA-12520-02 2500 CL-2501 C1 Press. Pressure gauge C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1775 PG-2508 DGA-12520-02 2500 HE-2503 C1 Feed Press. Pressure gauge C1 Gas 811.46 Nm3/h 624.2 Nm3/h 187.26 Nm3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1776 PG-2509 DGA-12520-02 2500 HE-2502 S2 Feed Press. Pressure gauge S2 Vapor 243.1 kg/h 187.0 kg/h 56.1 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 150.0 deg C 133.0 deg C 1.7 kg/m3 0.013 cP
1777 PG-2552 DGA-12520-02 2500 VE-2552 CM Press. Pressure gauge CM Vapor - - - 4.00 kgf/cm2G 1.50 kgf/cm2G 70.0 deg C 58.0 deg C 2.3 kg/Nm3 0.012 cP
1778 PG-2553A DGA-12520-02 2500 PU-2552/A Discharge Press. Pressure gauge CM Liquid 0.026 m3/h 0.0 m3/h 0.006 m3/h 8.00 kgf/cm2G 5.37 kgf/cm2G 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
64 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1779 PG-2553B DGA-12520-02 2500 PU-2552/B Discharge Press. Pressure gauge CM Liquid 0.026 m3/h 0.0 m3/h 0.006 m3/h 8.00 kgf/cm2G 5.37 kgf/cm2G 70.0 deg C 58.0 deg C 1014.0 kg/m3 0.168 cP
1780 PI-2503 DGA-12520-02 2500 CL-2501 C1 Press. Pressure transmitter C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1781 PIC-2504 DGA-12520-02 2500 CL-2501 C1 TOP Press. Pressure transmitter C1 Gas 811.46 Nm3/h 624.2 Nm3/h 187.26 Nm3/h 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1782 PIC-2504V/A DGA-12520-02 2500 HE-2503 CW Feed Control Valve Control Valve CW Liquid 79.43 m3/h 61.1 m3/h 18.33 m3/h 5.00 kgf/cm2G 3.00 kgf/cm2G 0.5 kg/cm2 60.0 deg C 35.0 deg C 994.0 kg/m3 0.73 cP
1787 FG-2551 DGA-12520-03 2500 EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1788 FI-2551 DGA-12520-03 2500 TK-2551 C4 Outlet Flow Flowmeter C4 Liquid 34.19 m3/h 26.3 m3/h 7.89 m3/h 6.00 kgf/cm2G 4.82 kgf/cm2G 60.0 deg C 37.2 deg C 1559.5 kg/m3 0.759 cP
1789 FIC-2552 DGA-12520-03 2500 TK-2551 C4 Outlet Flow Flowmeter C4 Liquid 1.04 m3/h 0.8 m3/h 0.24 m3/h 6.00 kgf/cm2G 4.82 kgf/cm2G 60.0 deg C 37.2 deg C 1559.5 kg/m3 0.759 cP
1791 LG-2551 DGA-12520-03 2500 CL-2551 C4 Level Level gauge C4 Liquid - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 0.0 deg C 1628.0 kg/m3 1.332 cP
1792 LG-2552 DGA-12520-03 2500 TK-2551 C4 Level Level gauge C4 Liquid - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 37.2 deg C 1559.5 kg/m3 0.759 cP
1794 LIC-2552 DGA-12520-03 2500 TK-2551 C4 Level Radar level meter C4 Liquid - - - 2.00 kgf/cm2G 1.00 kgf/cm2G 60.0 deg C 37.2 deg C 1559.5 kg/m3 0.759 cP
1795 LIC-2552V DGA-12520-03 2500 TK-2551 C4 Feed Control Valve Control Valve C4 Liquid 6.00 kgf/cm2G 3.96 kgf/cm2G 0.5 kg/cm2 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1796 PG-2551A DGA-12520-03 2500 PU-2551/A Discharge Press. Pressure gauge C4 Liquid 34.19 m3/h 26.3 m3/h 7.89 m3/h 6.00 kgf/cm2G 4.82 kgf/cm2G 60.0 deg C 37.2 deg C 1559.5 kg/m3 0.759 cP
1797 PG-2551B DGA-12520-03 2500 PU-2551/B Discharge Press. Pressure gauge C4 Liquid 34.19 m3/h 26.3 m3/h 7.89 m3/h 6.00 kgf/cm2G 4.82 kgf/cm2G 60.0 deg C 37.2 deg C 1559.5 kg/m3 0.759 cP
1798 PIC-2551 DGA-12520-03 2500 HE-2552 EG Outlet Press. Pressure transmitter EG Vapor 2.00 kgf/cm2G 1.00 kgf/cm2G -20.0 deg C -7.1 deg C 1.8 kg/Nm3 0.01 cP
1802 EV-A2601 DGA-12621-01 2600A HE-A2601 DHA Feed EV Automatic Valve DHA Liquid 18.46 m3/h 14.2 m3/h 4.26 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G - 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1803 EV-A2602 DGA-12621-01 2600A HE-A2603 S4 Feed EV Automatic Valve S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1804 EV-A2603 DGA-12621-01 2600A TK-2251 DHA Feed EV Automatic Valve DHA Liquid 8.00 kgf/cm2G 6.21 kgf/cm2G - 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1805 EV-A2604 DGA-12621-01 2600A VE-A2602 C1 Outlet SV Automatic Valve C1 Gas 2.00 kgf/cm2G 0.40 kgf/cm2G - 60.0 deg C 15.0 deg C 1.0 kg/Nm3 0.013 cP
65 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1806 FG-A2601 DGA-12621-01 2600A HE-A2604 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1807 FG-A2602 DGA-12621-01 2600A EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1808 FI-A2603 DGA-12621-01 2600A TK-A2601 MeOH Outlet Flow Flowmeter MeOH Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1811 FIC-A2604 DGA-12621-01 2600A TK-A2602 DHA Outlet Flow Flowmeter DHA Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 7.00 kgf/cm2G 5.68 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1813 FIC-A2605 DGA-12621-01 2600A CL-A2601 MeOH Feed Flow Flowmeter MeOH Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1815 FICQ-A2602 DGA-12621-01 2600A HE-A2603 S4 Feed Flow Flowmeter S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1817 LG-A2601 DGA-12621-01 2600A CL-A2601 DHA Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 130.0 deg C 115.0 deg C 1019.0 kg/m3 0.318 cP
1818 LG-A2602 DGA-12621-01 2600A TK-A2601 MeOH Level Level gauge MeOH Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1819 LG-A2603 DGA-12621-01 2600A TK-A2602 DHA Level Level gauge DHA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1820 LI-A2603 DGA-12621-01 2600A TK-A2602 DHA Level Differential press. Transmitter
DHA Liquid - - - F.L+0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1821 LIC-A2601 DGA-12621-01 2600A CL-A2601 DHA Level Differential press. Transmitter
DHA Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 130.0 deg C 115.0 deg C 1019.0 kg/m3 0.318 cP
1823 LIC-A2602 DGA-12621-01 2600A TK-A2601 MeOH Level Differential press. Transmitter
MeOH Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1825 PG-A2601 DGA-12621-01 2600A CL-A2601 DHA Press. Pressure gauge DHA Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 130.0 deg C 115.0 deg C 0.8 kg/Nm3 0.013 cP
1826 PG-A2602 DGA-12621-01 2600A HE-A2603 S4 Feed Press. Pressure gauge S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1827 PG-A2603 DGA-12621-01 2600A HE-A2603 S4 Feed Press. Pressure gauge S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
66 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1828 PG-A2604A DGA-12621-01 2600A PU-A2601/A Discharge Press. Pressure gauge MeOH Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 3.00 kgf/cm2G 1.98 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1829 PG-A2604B DGA-12621-01 2600A PU-A2601/B Discharge Press. Pressure gauge MeOH Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 3.00 kgf/cm2G 1.98 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1830 PG-A2605 DGA-12621-01 2600A HE-A2604 MeOH Feed Press. Pressure gauge MeOH Vapor 4745.26 Nm3/h 3650.2 Nm3/h 1095.06 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 130.0 deg C 110.0 deg C 0.8 kg/Nm3 0.013 cP
1831 PG-A2606A DGA-12621-01 2600A PU-A2602/A Discharge Press. Pressure gauge MeOH Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1832 PG-A2606B DGA-12621-01 2600A PU-A2602/B Discharge Press. Pressure gauge MeOH Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1833 PG-A2607A DGA-12621-01 2600A PU-A2603/A Discharge Press. Pressure gauge DHA Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 7.00 kgf/cm2G 5.68 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1834 PG-A2607B DGA-12621-01 2600A PU-A2603/B Discharge Press. Pressure gauge DHA Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 7.00 kgf/cm2G 5.68 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1835 PIC-A2601 DGA-12621-01 2600A VE-A2602 C1 Outlet Press. Pressure transmitter C1 Gas 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 15.0 deg C 1.0 kg/Nm3 0.013 cP
1845 EV-B2601 DGA-12622-01 2600B HE-B2601 DHA Feed EV Automatic Valve DHA Liquid 18.46 m3/h 14.2 m3/h 4.26 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G - 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1846 EV-B2602 DGA-12622-01 2600B HE-B2603 S4 Feed EV Automatic Valve S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G - 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1847 EV-B2603 DGA-12622-01 2600B TK-2251 DHA Feed EV Automatic Valve DHA Liquid 8.00 kgf/cm2G 6.21 kgf/cm2G - 60.0 deg C 40.0 deg C 1059.0 kg/m3 0.792 cP
1848 EV-B2604 DGA-12622-01 2600B VE-B2602 C1 Outlet SV Automatic Valve C1 Gas 2.00 kgf/cm2G 0.40 kgf/cm2G - 60.0 deg C 15.0 deg C 1.0 kg/Nm3 0.013 cP
1849 FG-B2601 DGA-12622-01 2600B HE-B2604 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1850 FG-B2602 DGA-12622-01 2600B EG Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1851 FI-B2603 DGA-12622-01 2600B TK-B2601 MeOH Outlet Flow Flowmeter MeOH Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1853 FIC-B2604 DGA-12622-01 2600B TK-B2602 DHA Outlet Flow Flowmeter DHA Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 7.00 kgf/cm2G 5.68 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1855 FIC-B2605 DGA-12622-01 2600B CL-B2601 MeOH Feed Flow Flowmeter MeOH Liquid 2.08 m3/h 1.6 m3/h 0.48 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1857 FICQ-B2602 DGA-12622-01 2600B HE-B2603 S4 Feed Flow Flowmeter S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
67 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1859 LG-B2601 DGA-12622-01 2600B CL-B2601 DHA Level Level gauge DHA Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 130.0 deg C 115.0 deg C 1019.0 kg/m3 0.318 cP
1860 LG-B2602 DGA-12622-01 2600B TK-B2601 MeOH Level Level gauge MeOH Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1861 LG-B2603 DGA-12622-01 2600B TK-B2602 DHA Level Level gauge DHA Liquid - - - F.L+0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1862 LI-B2603 DGA-12622-01 2600B TK-B2602 DHA Level Differential press. Transmitter
DHA Liquid - - - F.L+0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1863 LIC-B2601 DGA-12622-01 2600B CL-B2601 DHA Level Differential press. Transmitter
DHA Liquid - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 130.0 deg C 115.0 deg C 1019.0 kg/m3 0.318 cP
1865 LIC-B2602 DGA-12622-01 2600B TK-B2601 MeOH Level Differential press. Transmitter
MeOH Liquid - - - 2.00 kgf/cm2G 0.50 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1867 PG-B2601 DGA-12622-01 2600B CL-B2601 DHA Press. Pressure gauge DHA Vapor - - - 2.00 kgf/cm2G 0.80 kgf/cm2G 130.0 deg C 115.0 deg C 0.8 kg/Nm3 0.013 cP
1868 PG-B2602 DGA-12622-01 2600B HE-B2603 S4 Feed Press. Pressure gauge S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1869 PG-B2603 DGA-12622-01 2600B HE-B2603 S4 Feed Press. Pressure gauge S4 Vapor 5241.6 kg/h 4032.0 kg/h 1209.6 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 170.0 deg C 154.0 deg C 2.7 kg/m3 0.014 cP
1870 PG-B2604A DGA-12622-01 2600B PU-B2601/A Discharge Press. Pressure gauge MeOH Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 3.00 kgf/cm2G 1.98 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1871 PG-B2604B DGA-12622-01 2600B PU-B2601/B Discharge Press. Pressure gauge MeOH Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 3.00 kgf/cm2G 1.98 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1872 PG-B2605 DGA-12622-01 2600B HE-B2604 MeOH Feed Press. Pressure gauge MeOH Vapor 4745.26 Nm3/h 3650.2 Nm3/h 1095.06 Nm3/h 2.00 kgf/cm2G 0.50 kgf/cm2G 130.0 deg C 110.0 deg C 0.8 kg/Nm3 0.013 cP
1873 PG-B2606A DGA-12622-01 2600B PU-B2602/A Discharge Press. Pressure gauge MeOH Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1874 PG-B2606B DGA-12622-01 2600B PU-B2602/B Discharge Press. Pressure gauge MeOH Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 4.00 kgf/cm2G 3.22 kgf/cm2G 120.0 deg C 109.3 deg C 933.0 kg/m3 0.248 cP
1875 PG-B2607A DGA-12622-01 2600B PU-B2603/A Discharge Press. Pressure gauge DHA Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 7.00 kgf/cm2G 5.68 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1876 PG-B2607B DGA-12622-01 2600B PU-B2603/B Discharge Press. Pressure gauge DHA Liquid 16.64 m3/h 12.8 m3/h 3.84 m3/h 7.00 kgf/cm2G 5.68 kgf/cm2G 70.0 deg C 50.0 deg C 1063.0 kg/m3 0.708 cP
1877 PIC-B2601 DGA-12622-01 2600B VE-B2602 C1 Outlet Press. Pressure transmitter C1 Gas 2.00 kgf/cm2G 0.40 kgf/cm2G 60.0 deg C 15.0 deg C 1.0 kg/Nm3 0.013 cP
1887 EV-30011 DGA-13020-01 3000 TK-3001/1 C1 Feed EV Automatic Valve C1 Liquid 0.78 m3/h 0.6 m3/h 0.18 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.6 deg C 873.7 kg/m3 0.144 cP
68 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1888 EV-30012 DGA-13020-01 3000 TK-3001/2 C1 Feed EV Automatic Valve C1 Liquid 0.78 m3/h 0.6 m3/h 0.18 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.6 deg C 873.7 kg/m3 0.144 cP
1889 EV-30021 DGA-13020-01 3000 TK-3001/1 C1 Outlet EV Automatic Valve C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1890 EV-30022 DGA-13020-01 3000 TK-3001/2 C1 Outlet EV Automatic Valve C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1891 FG-30120 DGA-13020-01 3000 FL-3001 Purge Line N3 Feed Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
1892 LG-30011 DGA-13020-01 3000 TK-3001/1 Level Level gauge C1 Liquid - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/m3 0.144 cP
1893 LG-30012 DGA-13020-01 3000 TK-3001/2 Level Level gauge C1 Liquid - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/m3 0.144 cP
1894 LG-30120 DGA-13020-01 3000 TK-3012 Level Level gauge C1 Liquid - - - 15.00 kgf/cm2G 10.00 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1897 PG-30011 DGA-13020-01 3000 TK-3001/1 Press. Pressure gauge C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1898 PG-30012 DGA-13020-01 3000 TK-3001/2 Press. Pressure gauge C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1899 PG-30021 DGA-13020-01 3000 PU-3001/1 Discharge Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 14.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1900 PG-30022 DGA-13020-01 3000 PU-3001/2 Discharge Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 14.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1901 PG-30031 DGA-13020-01 3000 CL-3001/1 C1 Feed Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1902 PG-30032 DGA-13020-01 3000 CL-3001/2 C1 Feed Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1903 PG-30033 DGA-13020-01 3000 CL-3001/1 C1 Outlet Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1904 PG-30034 DGA-13020-01 3000 CL-3001/2 C1 Outlet Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1905 PG-30041 DGA-13020-01 3000 CL-3011/1 C1 Outlet Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1906 PG-30042 DGA-13020-01 3000 CL-3011/2 C1 Outlet Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1907 PG-30043 DGA-13020-01 3000 FL-3001/1 C1 Feed Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1908 PG-30044 DGA-13020-01 3000 FL-3001/2 C1 Feed Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1909 PG-30051 DGA-13020-01 3000 FL-3001/1 C1 Outlet Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
69 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1910 PG-30052 DGA-13020-01 3000 FL-3001/2 C1 Outlet Press. Pressure gauge C1 Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 15.00 kgf/cm2G 12.06 kgf/cm2G 60.0 deg C 41.6 deg C 873.7 kg/Nm3 0.144 cP
1911 PG-30060 DGA-13020-01 3000 TK-3012 C1 Outlet Press. Pressure gauge C1 Gas - - - 15.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1912 PI-30011 DGA-13020-01 3000 TK-3001/1 Press. Pressure transmitter C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1913 PI-30012 DGA-13020-01 3000 TK-3001/2 Press. Pressure transmitter C1 Gas - - - 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1914 PI-30030 DGA-13020-01 3000 TK-3012 C1 Outlet Press. Pressure transmitter C1 Gas - - - 15.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1915 PIC-30020 DGA-13020-01 3000 TK-3001/1,2 C1 Outlet Press. Pressure transmitter C1 Gas 10.00 kgf/cm2G 8.00 kgf/cm2G 60.0 deg C 41.6 deg C 2.3 kg/Nm3 0.012 cP
1917 SV-30011 DGA-13020-01 3000 TK-3001/1 C1 Feed SV Automatic Valve C1 Liquid 0.78 m3/h 0.6 m3/h 0.18 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.6 deg C 873.7 kg/m3 0.144 cP
1918 SV-30012 DGA-13020-01 3000 TK-3001/2 C1 Feed SV Automatic Valve C1 Liquid 0.78 m3/h 0.6 m3/h 0.18 m3/h 10.00 kgf/cm2G 8.00 kgf/cm2G - 60.0 deg C 41.6 deg C 873.7 kg/m3 0.144 cP
1921 EV-30031 DGA-13020-02 3000 TK-3002/1 C2 Outlet EV Automatic Valve C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1922 EV-30032 DGA-13020-02 3000 TK-3002/2 C2 Outlet EV Automatic Valve C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1923 EV-30033 DGA-13020-02 3000 TK-3002/3 C2 Outlet EV Automatic Valve C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1924 LG-30021 DGA-13020-02 3000 TK-3002/1 Level Level gauge C2 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1925 LG-30022 DGA-13020-02 3000 TK-3002/2 Level Level gauge C2 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1926 LG-30023 DGA-13020-02 3000 TK-3002/3 Level Level gauge C2 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1930 PG-30071 DGA-13020-02 3000 PU-3002/1 Discharge Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1931 PG-30072 DGA-13020-02 3000 PU-3002/2 Discharge Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1932 PG-30073 DGA-13020-02 3000 PU-3002/3 Discharge Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1933 PG-30081 DGA-13020-02 3000 CL-3002/1 C2 Feed Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
70 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1934 PG-30082 DGA-13020-02 3000 CL-3002/2 C2 Feed Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1935 PG-30083 DGA-13020-02 3000 CL-3002/3 C2 Feed Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1936 PG-30084 DGA-13020-02 3000 CL-3002/1 C2 Outlet Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1937 PG-30085 DGA-13020-02 3000 CL-3002/2 C2 Outlet Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1938 PG-30086 DGA-13020-02 3000 CL-3002/3 C2 Outlet Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1939 PG-30091 DGA-13020-02 3000 CL-3012/1 C2 Outlet Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1940 PG-30092 DGA-13020-02 3000 CL-3012/2 C2 Outlet Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1941 PG-30093 DGA-13020-02 3000 CL-3012/3 C2 Outlet Press. Pressure gauge C2 Liquid 32.5 m3/h 25.0 m3/h 7.5 m3/h 5.00 kgf/cm2G 3.83 kgf/cm2G 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1942 PI-30041 DGA-13020-02 3000 TK-3002/1 Press. Pressure transmitter C2 Liquid - - - 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1943 PI-30042 DGA-13020-02 3000 TK-3002/2 Press. Pressure transmitter C2 Liquid - - - 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1944 PI-30043 DGA-13020-02 3000 TK-3002/3 Press. Pressure transmitter C2 Liquid - - - 60.0 deg C 30.0 deg C 1309.0 kg/m3 0.395 cP
1945 SV-30021 DGA-13020-02 3000 TK-3002/1 C2 Feed SV Automatic Valve C2 Liquid 8.58 m3/h 6.6 m3/h 1.98 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1335.0 kg/m3 0.447 cP
1946 SV-30022 DGA-13020-02 3000 TK-3002/2 C2 Feed SV Automatic Valve C2 Liquid 8.58 m3/h 6.6 m3/h 1.98 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1335.0 kg/m3 0.447 cP
1947 SV-30023 DGA-13020-02 3000 TK-3002/3 C2 Feed SV Automatic Valve C2 Liquid 8.58 m3/h 6.6 m3/h 1.98 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1335.0 kg/m3 0.447 cP
1954 EV-30041 DGA-13020-03 3000 TK-3003/1 C3 Outlet EV Automatic Valve C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1955 EV-30042 DGA-13020-03 3000 TK-3003/2 C3 Outlet EV Automatic Valve C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1956 LG-30031 DGA-13020-03 3000 TK-3003/1 Level Level gauge C3 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1957 LG-30032 DGA-13020-03 3000 TK-3003/2 Level Level gauge C3 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1960 PG-30101 DGA-13020-03 3000 PU-3003/1 Discharge Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1961 PG-30102 DGA-13020-03 3000 PU-3003/2 Discharge Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
71 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1962 PG-30111 DGA-13020-03 3000 CL-3003/1 C3 Feed Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1963 PG-30112 DGA-13020-03 3000 CL-3003/2 C3 Feed Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1964 PG-30113 DGA-13020-03 3000 CL-3003/1 C3 Outlet Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1965 PG-30114 DGA-13020-03 3000 CL-3003/2 C3 Outlet Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1966 PG-30121 DGA-13020-03 3000 CL-3013/1 C3 Outlet Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1967 PG-30122 DGA-13020-03 3000 CL-3013/2 C3 Outlet Press. Pressure gauge C3 Liquid 13 m3/h 10.0 m3/h 3 m3/h 6.00 kgf/cm2G 3.95 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1968 PI-30051 DGA-13020-03 3000 TK-3003/1 Press. Pressure transmitter C3 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1969 PI-30052 DGA-13020-03 3000 TK-3003/2 Press. Pressure transmitter C3 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1970 SV-30031 DGA-13020-03 3000 TK-3003/1 C3 Feed SV Automatic Valve C3 Liquid 2.86 m3/h 2.2 m3/h 0.66 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1971 SV-30032 DGA-13020-03 3000 TK-3003/2 C3 Feed SV Automatic Valve C3 Liquid 2.86 m3/h 2.2 m3/h 0.66 m3/h 2.00 kgf/cm2G 0.50 kgf/cm2G - 60.0 deg C 15.0 deg C 1497.6 kg/m3 0.587 cP
1976 EV-30051 DGA-13020-04 3000 TK-3004/1 C4 Outlet EV Automatic Valve C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1977 EV-30052 DGA-13020-04 3000 TK-3004/2 C4 Outlet EV Automatic Valve C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1978 LG-30041 DGA-13020-04 3000 TK-3004/1 Level Level gauge C4 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1979 LG-30042 DGA-13020-04 3000 TK-3004/2 Level Level gauge C4 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1982 PG-30131 DGA-13020-04 3000 PU-3004/1 Discharge Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1983 PG-30132 DGA-13020-04 3000 PU-3004/2 Discharge Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1984 PG-30141 DGA-13020-04 3000 CL-3004/1 C4 Feed Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1985 PG-30142 DGA-13020-04 3000 CL-3004/2 C4 Feed Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1986 PG-30143 DGA-13020-04 3000 CL-3004/1 C4 Outlet Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1987 PG-30144 DGA-13020-04 3000 CL-3004/2 C4 Outlet Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
72 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
1988 PG-30151 DGA-13020-04 3000 CL-3014/1 C4 Outlet Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1989 PG-30152 DGA-13020-04 3000 CL-3014/2 C4 Outlet Press. Pressure gauge C4 Liquid 2.6 m3/h 2.0 m3/h 0.6 m3/h 6.00 kgf/cm2G 3.96 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1990 PI-30061 DGA-13020-04 3000 TK-3004/1 Press. Pressure transmitter C4 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1991 PI-30062 DGA-13020-04 3000 TK-3004/2 Press. Pressure transmitter C4 Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1992 SV-30041 DGA-13020-04 3000 TK-3004/1 C4 Feed SV Automatic Valve C4 Liquid 0.39 m3/h 0.3 m3/h 0.09 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G - 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1993 SV-30042 DGA-13020-04 3000 TK-3004/2 C4 Feed SV Automatic Valve C4 Liquid 0.39 m3/h 0.3 m3/h 0.09 m3/h 8.00 kgf/cm2G 5.17 kgf/cm2G - 70.0 deg C 50.0 deg C 1536.9 kg/m3 0.652 cP
1996 EV-30061 DGA-13020-05 3000 TK-3005/1 CHA Outlet EV Automatic Valve CHA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
1997 EV-30062 DGA-13020-05 3000 TK-3005/2 CHA Outlet EV Automatic Valve CHA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
1998 EV-30063 DGA-13020-05 3000 TK-3005/3 CHA Outlet EV Automatic Valve CHA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2000 FG-30020 DGA-13020-05 3000 HA Line N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
2001 LG-30051 DGA-13020-05 3000 TK-3005/1 Level Level gauge CHA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2002 LG-30052 DGA-13020-05 3000 TK-3005/2 Level Level gauge CHA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2003 LG-30053 DGA-13020-05 3000 TK-3005/3 Level Level gauge CHA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2007 PG-3016A DGA-13020-05 3000 PU-3005/A Discharge Press. Pressure gauge CHA Liquid 39 m3/h 30.0 m3/h 9 m3/h 4.00 kgf/cm2G 2.73 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2008 PG-3016B DGA-13020-05 3000 PU-3005/B Discharge Press. Pressure gauge CHA Liquid 39 m3/h 30.0 m3/h 9 m3/h 4.00 kgf/cm2G 2.73 kgf/cm2G 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2009 SV-30051 DGA-13020-05 3000 TK-3005/1 CHA Feed SV Automatic Valve CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G - 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2010 SV-30052 DGA-13020-05 3000 TK-3005/2 CHA Feed SV Automatic Valve CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G - 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
2011 SV-30053 DGA-13020-05 3000 TK-3005/3 CHA Feed SV Automatic Valve CHA Liquid 5.2 m3/h 4.0 m3/h 1.2 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G - 60.0 deg C 30.0 deg C 1149.0 kg/m3 1.473 cP
73 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2015 EV-30080 DGA-13020-06 3000 TK-3006 CS Outlet EV Automatic Valve CS Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h F.L + 0.03 kgf/cm2G
ATM - 60.0 deg C 30.0 deg C 1267.2 kg/m3 4.181 cP
2016 EV-30101 DGA-13020-06 3000 TK-3007/1 SA Outlet EV Automatic Valve SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h F.L + 0.03 kgf/cm2G
ATM - 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2017 EV-30102 DGA-13020-06 3000 TK-3007/2 SA Outlet EV Automatic Valve SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h F.L + 0.03 kgf/cm2G
ATM - 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2018 FG-30031 DGA-13020-06 3000 TK-3007/1 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
2019 FG-30032 DGA-13020-06 3000 TK-3007/2 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
2020 FIQ-30010 DGA-13020-06 3000 PU-3006/A,B Discharge Flow Flowmeter CS Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 7.00 kgf/cm2G 5.14 kgf/cm2G 60.0 deg C 35.0 deg C 1267.2 kg/m3 4.181 cP
2021 FIQ-30020 DGA-13020-06 3000 PU-3007/A,B Discharge Flow Flowmeter SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2022 LG-30060 DGA-13020-06 3000 TK-3006 Level Level gauge CS Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 30.0 deg C 1267.2 kg/m3 4.181 cP
2023 LG-30071 DGA-13020-06 3000 TK-3007/1 Level Level gauge SA Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2024 LG-30072 DGA-13020-06 3000 TK-3007/2 Level Level gauge SA Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2025 LI-30060 DGA-13020-06 3000 TK-3006 Level Liquid level TransmitterCS Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 30.0 deg C 1267.2 kg/m3 4.181 cP
2026 LI-30071 DGA-13020-06 3000 TK-3007/1 Level Liquid level TransmitterSA Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2027 LI-30072 DGA-13020-06 3000 TK-3007/2 Level Liquid level TransmitterSA Liquid - - - F.L + 0.03 kgf/cm2G
ATM 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2028 PG-3017A DGA-13020-06 3000 PU-3006/A Discharge Press. Pressure gauge CS Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 7.00 kgf/cm2G 5.14 kgf/cm2G 60.0 deg C 35.0 deg C 1267.2 kg/m3 4.181 cP
2029 PG-3017B DGA-13020-06 3000 PU-3006/B Discharge Press. Pressure gauge CS Liquid 1.95 m3/h 1.5 m3/h 0.45 m3/h 7.00 kgf/cm2G 5.14 kgf/cm2G 60.0 deg C 35.0 deg C 1267.2 kg/m3 4.181 cP
2030 PG-3018A DGA-13020-06 3000 PU-3007/A Discharge Press. Pressure gauge SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G 60.0 deg C 35.0 deg C 1819.6 kg/m3 21.61 cP
2031 PG-3018B DGA-13020-06 3000 PU-3007/B Discharge Press. Pressure gauge SA Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 9.00 kgf/cm2G 6.30 kgf/cm2G 60.0 deg C 35.0 deg C 1819.6 kg/m3 21.61 cP
2032 SV-30060 DGA-13020-06 3000 TK-3006 CS Feed SV Automatic Valve CS Liquid 5.85 m3/h 4.5 m3/h 1.35 m3/h 3.00 kgf/cm2G - 60.0 deg C 30.0 deg C 1267.2 kg/m3 4.181 cP
2033 SV-30071 DGA-13020-06 3000 TK-3007/1 SA Feed SV Automatic Valve SA Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2034 SV-30072 DGA-13020-06 3000 TK-3007/2 SA Feed SV Automatic Valve SA Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 3.00 kgf/cm2G - 60.0 deg C 30.0 deg C 1819.6 kg/m3 21.61 cP
2035 EV-30110 DGA-13020-07 3000 TK-3008 WCS Outlet EV Automatic Valve WCS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h F.L + 0.03 kgf/cm2G
ATM - 90.0 deg C 70.0 deg C 1120.1 kg/m3 0.718 cP
2036 FG-30040 DGA-13020-07 3000 PU-3008/A,B Discharge Flow Area Flowmeter WCS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 7.00 kgf/cm2G 2.70 kgf/cm2G 90.0 deg C 70.0 deg C 1120.1 kg/m3 0.718 cP
74 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2037 FG-30050 DGA-13020-07 3000 CL-3008 WCS Feed Flow Area Flowmeter WCS Liquid 1.82 m3/h 1.4 m3/h 0.42 m3/h 5.00 kgf/cm2G 3.23 kgf/cm2G 90.0 deg C 70.0 deg C 1120.1 kg/m3 0.718 cP
2038 FG-30060 DGA-13020-07 3000 CL-3008 WCS Feed Flow Area Flowmeter WCS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 4.00 kgf/cm2G 2.30 kgf/cm2G 60.0 deg C 40.0 deg C 1267.0 kg/m3 4.181 cP
2039 LG-30080 DGA-13020-07 3000 TK-3008 Level Level gauge WCS Liquid - - - F.L + 0.03 kgf/cm2G
ATM 90.0 deg C 70.0 deg C 1120.1 kg/m3 0.718 cP
2040 LG-30180 DGA-13020-07 3000 CL-3008 Level Level gauge WCS Liquid - - - 2.00 kgf/cm2G 0.03 kgf/cm2G 60.0 deg C 40.0 deg C 1267.0 kg/m3 4.181 cP
2041 LI-30080 DGA-13020-07 3000 TK-3008 Level Liquid level TransmitterWCS Liquid - - - F.L + 0.03 kgf/cm2G
ATM 90.0 deg C 70.0 deg C 1120.1 kg/m3 0.718 cP
2042 LIC-30180 DGA-13020-07 3000 CL-3008 Btm Level Differential press. Transmitter
WCS Liquid - - - 2.00 kgf/cm2G 0.03 kgf/cm2G 60.0 deg C 40.0 deg C 1267.0 kg/m3 4.181 cP
2044 PG-3019A DGA-13020-07 3000 PU-3008/A Discharge Press. Pressure gauge WCS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 6.00 kgf/cm2G 2.70 kgf/cm2G 90.0 deg C 70.0 deg C 1120.1 kg/m3 0.718 cP
2045 PG-3019B DGA-13020-07 3000 PU-3008/B Discharge Press. Pressure gauge WCS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 6.00 kgf/cm2G 2.70 kgf/cm2G 90.0 deg C 70.0 deg C 1120.1 kg/m3 0.718 cP
2046 PG-3020A DGA-13020-07 3000 PU-3018/A Discharge Press. Pressure gauge WCS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 4.00 kgf/cm2G 2.30 kgf/cm2G 60.0 deg C 40.0 deg C 1267.0 kg/m3 4.181 cP
2047 PG-3020B DGA-13020-07 3000 PU-3018/B Discharge Press. Pressure gauge WCS Liquid 3.9 m3/h 3.0 m3/h 0.9 m3/h 4.00 kgf/cm2G 2.30 kgf/cm2G 60.0 deg C 40.0 deg C 1267.0 kg/m3 4.181 cP
2048 EV-30121 DGA-13020-08 3000 TK-3009/1 WSA Outlet EV Automatic Valve WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2049 EV-30122 DGA-13020-08 3000 TK-3009/2 WSA Outlet EV Automatic Valve WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2050 EV-30123 DGA-13020-08 3000 TK-3009/3 WSA Outlet EV Automatic Valve WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2051 EV-30130 DGA-13020-08 3000 TK-3010 WSA Outlet EV Automatic Valve WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G - 60.0 deg C 40.9 deg C 1542.0 kg/m3 6.266 cP
2052 FG-30070 DGA-13020-08 3000 PU-3009/A,B Discharge Flow Area Flowmeter WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h 7.00 kgf/cm2G 3.02 kgf/cm2G 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2053 FG-30080 DGA-13020-08 3000 PU-3010/A,B Discharge Flow Area Flowmeter WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h 7.00 kgf/cm2G 2.97 kgf/cm2G 60.0 deg C 40.9 deg C 1542.0 kg/m3 6.266 cP
2054 LG-30091 DGA-13020-08 3000 TK-3009/1 Level Level gauge WSA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2055 LG-30092 DGA-13020-08 3000 TK-3009/2 Level Level gauge WSA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2056 LG-30093 DGA-13020-08 3000 TK-3009/3 Level Level gauge WSA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2057 LG-30100 DGA-13020-08 3000 TK-3010 Level Level gauge WSA Liquid - - - F.L + 0.03 kgf/cm2G
0.02 kgf/cm2G 60.0 deg C 40.9 deg C 1542.0 kg/m3 6.266 cP
75 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2062 PG-3021A DGA-13020-08 3000 PU-3009/A Discharge Press. Pressure gauge WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h 7.00 kgf/cm2G 3.02 kgf/cm2G 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2063 PG-3021B DGA-13020-08 3000 PU-3009/B Discharge Press. Pressure gauge WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h 7.00 kgf/cm2G 3.02 kgf/cm2G 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2064 PG-3022A DGA-13020-08 3000 PU-3010/A Discharge Press. Pressure gauge WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h 7.00 kgf/cm2G 2.97 kgf/cm2G 60.0 deg C 40.9 deg C 1542.0 kg/m3 6.266 cP
2065 PG-3022B DGA-13020-08 3000 PU-3010/B Discharge Press. Pressure gauge WSA Liquid 26 m3/h 20.0 m3/h 6 m3/h 7.00 kgf/cm2G 2.97 kgf/cm2G 60.0 deg C 40.9 deg C 1542.0 kg/m3 6.266 cP
2066 SV-30091 DGA-13020-08 3000 TK-3009/1 WSA Feed SV Automatic Valve WSA Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2067 SV-30092 DGA-13020-08 3000 TK-3009/2 WSA Feed SV Automatic Valve WSA Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2068 SV-30093 DGA-13020-08 3000 TK-3009/3 WSA Feed SV Automatic Valve WSA Liquid 0.65 m3/h 0.5 m3/h 0.15 m3/h 6.00 kgf/cm2G 3.87 kgf/cm2G - 60.0 deg C 40.8 deg C 1628.6 kg/m3 5.511 cP
2069 FG-30090 DGA-13020-09 3000 TK-3011 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
2070 FG-30100 DGA-13020-09 3000 PU-3011/A,B Discharge Flow Area Flowmeter SC Liquid 39 m3/h 30.0 m3/h 9 m3/h 7.00 kgf/cm2G 4.62 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2071 FG-30110 DGA-13020-09 3000 PU-3013 Discharge Flow Area Flowmeter CM Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 60.0 deg C 30.0 deg C 1344.0 kg/m3 0.384 cP
2072 LG-30110 DGA-13020-09 3000 TK-3011 Level Level gauge SC Liquid - - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2073 LG-30130 DGA-13020-09 3000 TK-3013 Level Level gauge CM Liquid - - - F.L ATM 60.0 deg C 30.0 deg C 1344.0 kg/m3 0.384 cP
2074 LI-30110 DGA-13020-09 3000 TK-3011 Level Liquid level TransmitterSC Liquid - - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2075 PG-3023A DGA-13020-09 3000 PU-3011/A Discharge Press. Pressure gauge SC Liquid 39 m3/h 30.0 m3/h 9 m3/h 7.00 kgf/cm2G 4.62 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2076 PG-3023B DGA-13020-09 3000 PU-3011/B Discharge Press. Pressure gauge SC Liquid 39 m3/h 30.0 m3/h 9 m3/h 7.00 kgf/cm2G 4.62 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2077 PG-30240 DGA-13020-09 3000 PU-3013 Discharge Press. Pressure gauge CM Liquid 1.3 m3/h 1.0 m3/h 0.3 m3/h 60.0 deg C 30.0 deg C 1344.0 kg/m3 0.384 cP
76 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2083 FG-A35021 DGA-13020-10 3000 TK-1705 Feed Flow A Area Flowmeter C2 Liquid
2084 FG-A35022 DGA-13020-10 3000 TK-3002/1,2,3 Feed Flow A Area Flowmeter C2 Liquid
2085 FG-B35021 DGA-13020-10 3000 TK-1705 Feed Flow B Area Flowmeter C2 Liquid
2086 FG-B35022 DGA-13020-10 3000 TK-3002/1,2,3 Feed Flow B Area Flowmeter C2 Liquid
2095 PG-A35021 DGA-13020-10 3000 PU-A3502/1 Discharge Press. Pressure gauge C2 Liquid
2096 PG-A35022 DGA-13020-10 3000 PU-A3502/2 Discharge Press. Pressure gauge C2 Liquid
2097 PG-B35021 DGA-13020-10 3000 PU-B3502/1 Discharge Press. Pressure gauge C2 Liquid
2098 PG-B35022 DGA-13020-10 3000 PU-B3502/2 Discharge Press. Pressure gauge C2 Liquid
77 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2109 FG-35031 DGA-13020-11 3000 TK-1704 C3 Feed Flow Area Flowmeter C3 Liquid
2110 FG-35032 DGA-13020-11 3000 TK-3003/1,2 Feed Flow Area Flowmeter C3 Liquid
2115 PG-35031 DGA-13020-11 3000 PU-3503/1 Discharge Press. Pressure gauge C3 Liquid
2116 PG-35032 DGA-13020-11 3000 PU-3503/2 Discharge Press. Pressure gauge C3 Liquid
2123 FG-35041 DGA-13020-12 3000 TK-1704 C4 Feed Flow Area Flowmeter C4 Liquid
2124 FG-35042 DGA-13020-12 3000 TK-3004/1,2 Feed Flow Area Flowmeter C4 Liquid
78 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2129 PG-35041 DGA-13020-12 3000 PU-3504/1 Discharge Press. Pressure gauge C4 Liquid
2130 PG-35042 DGA-13020-12 3000 PU-3504/2 Discharge Press. Pressure gauge C4 Liquid
2135 EV-5001 DGA-15020-07 5000 S2 Main Header EV Automatic Valve S2 Vapor 14300 kg/h 11000.0 kg/h 3300 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 120.0 deg C 133.0 deg C 1.6 kg/m3 0.013 cP
2136 EV-A5002 DGA-15020-07 5000 S4 #1800 Header A Train EV Automatic Valve S4 Vapor 2003 kg/h 1894.0 kg/h 568.2 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 120.0 deg C 154.0 deg C 3.4 kg/m3 0.014 cP
2137 EV-B5002 DGA-15020-07 5000 S4 #1800 Header B Train EV Automatic Valve S4 Vapor 2232 kg/h 1611.0 kg/h 483.3 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 120.0 deg C 154.0 deg C 1.6 kg/m3 0.014 cP
2138 PIC-5001 DGA-15020-07 5000 S2 Main Press. Pressure transmitter S2 Vapor 12308.7 kg/h 7028.9 kg/h 2108.67 kg/h 3.00 kgf/cm2G 2.00 kgf/cm2G 120.0 deg C 133.0 deg C 1.6 kg/m3 0.013 cP
S7 to S2 Depressurized Pressure
2139 PIC-5001V/A DGA-15020-07 5000 Control Valve S7 Vapor 12308.7 kg/h 7028.9 kg/h 2108.67 kg/h 8.00 kgf/cm2G 7.00 kgf/cm2G 0.1 kg/cm2 120.0 deg C 171.0 deg C 7.9 kg/m3 0.016 cP
Control Valve
S7 to S2 Depressurized Pressure
2140 PIC-5001V/B DGA-15020-07 5000 Control Valve S7 Vapor 12308.7 kg/h 1405.6 kg/h 421.68 kg/h 8.00 kgf/cm2G 7.00 kgf/cm2G 0.1 kg/cm2 120.0 deg C 171.0 deg C 7.9 kg/m3 0.016 cP
Control Valve
2141 PIC-5002 DGA-15020-07 5000 S4 Main Pressure Pressure transmitter S4 Vapor 22950.72 kg/h 17654.4 kg/h 5296.32 kg/h 5.00 kgf/cm2G 4.00 kgf/cm2G 120.0 deg C 154.0 deg C 3.4 kg/m3 0.014 cP
S7 to S2 Depressurized Pressure
2142 PIC-5002V DGA-15020-07 5000 Control Valve S7 Vapor 22950.72 kg/h 17654.4 kg/h 5296.32 kg/h 8.00 kgf/cm2G 7.00 kgf/cm2G 0.1 kg/cm2 120.0 deg C 171.0 deg C 7.9 kg/m3 0.016 cP
Control Valve
2143 FG-A1802 DGA-15020-08 5000 TK-A1801 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
2144 FG-B1802 DGA-15020-08 5000 TK-B1801 N3 Feed Flow Area Flowmeter N3 Gas 0.65 Nm3/h 0.5 Nm3/h 0.15 Nm3/h 6.00 kgf/cm2G 3.00 kgf/cm2G 60.0 deg C 30.0 deg C 4.4 kg/m3 0.018 cP
2145 LG-A1802 DGA-15020-08 5000 TK-A1801 SC Level Level gauge SC Liquid - - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2146 LG-B1802 DGA-15020-08 5000 TK-B1801 SC Level Level gauge SC Liquid - - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2147 LIC-A1802 DGA-15020-08 5000 TK-A1801 SC Level Liquid level TransmitterSC Liquid - - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
79 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2148 LIC-A1802V DGA-15020-08 5000 TK-3011 SC Feed Control Valve Control Valve SC Liquid 13 m3/h 10.0 m3/h 3 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 0.5 kg/cm2 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2149 LIC-B1802 DGA-15020-08 5000 TK-B1801 SC Level Liquid level TransmitterSC Liquid - - - F.L ATM 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2150 LIC-B1802V DGA-15020-08 5000 TK-3011 SC Feed Control Valve Control Valve SC Liquid 13 m3/h 10.0 m3/h 3 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 0.5 kg/cm2 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2151 PG-A1802A DGA-15020-08 5000 PU-A1801/A Discharge Press. Pressure gauge SC Liquid 13 m3/h 10.0 m3/h 3 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2152 PG-A1802B DGA-15020-08 5000 PU-A1801/B Discharge Press. Pressure gauge SC Liquid 13 m3/h 10.0 m3/h 3 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2153 PG-B1802A DGA-15020-08 5000 PU-B1801/A Discharge Press. Pressure gauge SC Liquid 13 m3/h 10.0 m3/h 3 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2154 PG-B1802B DGA-15020-08 5000 PU-B1801/B Discharge Press. Pressure gauge SC Liquid 13 m3/h 10.0 m3/h 3 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2155 QI-A1801 DGA-15020-08 5000 TK-A1801 SC Feed Quality Conductivity Meter SC Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2156 QI-B1801 DGA-15020-08 5000 TK-B1801 SC Feed Quality Conductivity Meter SC Liquid 4.16 m3/h 3.2 m3/h 0.96 m3/h 8.00 kgf/cm2G 6.21 kgf/cm2G 120.0 deg C 100.0 deg C 957.0 kg/m3 0.28 cP
2157 GIA-0001 DGA-63000-01 1300A-West CH4 Gas Detector Gas detector MT Gas
2158 GIA-0002 DGA-63000-01 1400A-West CH4 Gas Detector Gas detector MT Gas
2159 GIA-0003 DGA-63000-01 1400A-East CH4 Gas Detector Gas detector MT Gas
2160 GIA-0004 DGA-63000-01 1100A-West CH4 Gas Detector Gas detector MT Gas
2161 GIA-0005 DGA-63000-01 1100A-East CH4 Gas Detector Gas detector MT Gas
2162 GIA-0006 DGA-63000-01 1500A-West CH4 Gas Detector Gas detector MT Gas
2163 GIA-0007 DGA-63000-01 1500A-East CH4 Gas Detector Gas detector MT Gas
2164 GIA-0008 DGA-63000-01 1300B-West CH4 Gas Detector Gas detector MT Gas
2165 GIA-0009 DGA-63000-01 1400B-West CH4 Gas Detector Gas detector MT Gas
2166 GIA-0010 DGA-63000-01 1400B-East CH4 Gas Detector Gas detector MT Gas
2167 GIA-0011 DGA-63000-01 1100B-West CH4 Gas Detector Gas detector MT Gas
2168 GIA-0012 DGA-63000-01 1100B-East CH4 Gas Detector Gas detector MT Gas
2169 GIA-0013 DGA-63000-01 1500B-West CH4 Gas Detector Gas detector MT Gas
80 / 81
SECTION TYPE OF
NO. TAG.No. P&ID No. SERVICE NAME FLUID CONDITION
No. INSTRUMENT
DESIGN DIF. DESIGN
FLUID PHASE MAX.FLOW NOR.FLOW MIN.FLOW PRESSURE TEMP. DENSITY VISCOSITY
PRESSURE PRESSURE TEMP.
2170 GIA-0014 DGA-63000-01 1500B-East CH4 Gas Detector Gas detector MT Gas
2171 GIA-0015 DGA-63000-01 1600-West CH4 Gas Detector Gas detector MT Gas
2183 GIA-0027 DGA-63000-01 2500-East CH3CL Gas Detector Gas detector CM Gas
2184 GIA-0028 DGA-63000-01 2400-West CH3CL Gas Detector Gas detector CM Gas
2185 GIA-0029 DGA-63000-01 2400-East CH3CL Gas Detector Gas detector CM Gas
81 / 81