Vous êtes sur la page 1sur 1

TEST REPORT

Memo No. : BRTC/TEST/CE/2019/1135 Date: 24/03/2019


Supplier : Upazila Engineer, LGED, Rangunia, Chattogram
Ref. No. : ৪৬. ০২. ১৫৭০. ৮৭৮. ১৪. ০০২. ১৮- ১৯৪ Date: 24/03/2019
Name of the Test : Diameter, Tensile Strength, Elongation and Unit weight Test of Rebar (Brand: RSRM-400W)
Location : Construction of Class Room at Ghagra Satghariapara Govt. Primary School under the Project
NBIDGPS-1
Sample : Sealed

Elongation

Elongation
Actual Dia

Avg. Avg. Avg.


Nominal

Re-bend
Yield Ult. Avg. Ult. Unit
(mm)

Bend
Avg.
Actual Yield US/Y Unit

(%)

(%)
Dia

Strength Strength Strength Weight


Dia Strength S Weight
(MPa) (MPa) (MPa) (kg/m)
(mm) (MPa) (kg/m)
20.20 427.2 626.8 1.47 19.21 2.47
20 20.17 20.20 0.0 142.4 0.0 208.9 #DIV/0!#DIV/0! #DIV/0! 2.46 2.47 --- ---
20.23 0.0 0.0 #DIV/0!#DIV/0! 2.47
--- --- --- --- --- ---
--- --- --- --- --- --- --- --- --- --- --- --- --- ---
--- --- --- --- --- ---
--- --- --- --- --- ---
--- --- --- --- --- --- --- --- --- --- --- --- --- ---
--- --- --- --- --- ---
--- --- --- --- --- ---
--- --- --- --- --- --- --- --- --- --- --- --- --- ---
--- --- --- --- --- ---
Explanatory Notes: 1MPa = 145.048 psi, S=Satisfactory, U=Unsatisfactory
ASTM A615-16 Weight Requirements & Nominal Area of bars (Table A1.1)

Nominal Dia, mm 10 12 16 20 22 25 28 32 36 40 50 60

Nominal Area, sq
79 113 201 314 380 491 616 804 1018 1257 1963 2827
mm
Nominal Weight,
0.617 0.888 1.578 2.466 2.984 3.853 4.834 6.313 7.990 9.865 15.41 22.2
kg/m
• Measured unit weight shall not be less ASTM A 615M-16 Tensile Requirements for Common Steel Grades
than 94% of the nominal weight Grade 60 (420) Grade 75 (520) Grade 80 (550)
• Area & weight of 22mm dia bar is derived Tensile strength min. MPa (psi) 620 (90000) 690 (100000) 725 (105000)
based on principle followed for other sizes 420 (60000) 520 (75000) 550 (80000)
Yield strength, min MPa (psi)
in Table A1.1
Elongation in 200mm (8in), min %
• Actual dia & US/YS ratio are provided for
informative purpose only. Bar designation No.
These are not requirements of ASTM 10,12,16,20 9 7 7
A615M-16 25,22 8 7 7
28,32,36,40,50,60 7 6 6

Countersigned by Test Conducted by

Head (Dr. Mahmood Omar Imam)


Department of Civil Engineering
Chittagong University of Engineering and Technology