Vous êtes sur la page 1sur 1

Page 1 of 1

Inputs to DC Reactor Core Design Tool

DC High Freq Insulator Former Ambient Air Number of Core


Inductance Ipeak Frequency
Current Ripple Thickness Thickness Temp Flow Gaps Size
henries Amps Amps Amps Hz cm cm °C cfm
0.000138 177 154 46 16000 0.013 0.2 55 0 2 AMCC630

Core size selected by Designer AMCC630

Summary of DC Reactor Design

No.of Turns Copper Area Copper Thknss Copper Width Total Gap Spacer Per Leg Copper Loss Core Loss Total Temp
. sq.cm cm cm mm mm watts watts °C
15 0.46 0.07 6.9 2.9 1.5 46.69 56.48 121

CORE DETAILS
NOTE:
1)
Calculations
are for still air
with no
cooling
device.
2) High
frequency
losses are
only
calculated for
fundamental.
3) Rac is
based on the
Dowell
formula.
4) One coil on
the core is
assumed for
surface area
calculation.

Core Data
A B C D E F Lm Ac Mass Wa WaAc
Part No.
mm mm mm mm mm mm cm sq.cm kg sq.cm cm4
AMCC630 25 40 85 70 90 135 35.6 14.3 3.67 34 486.2
AMCC630 * 1 25 40 85 70 90 135 35.6 14.3 3.67 34 486.2

METGLAS ALLOY2605SA1 MASS +(-) 3%

Designs generated by this software are believed to be accurate and reliable , but are presented without guarantee or warranty,
expressed or implied. Designer needs to verify all the information provided in this software using it in actual circuitry.
Any additional design questions should be directed to: Metglas Inc. Applications Development Group at 1-800-581-7654 OR e-
mail questions to Metglas@metglas.com.

file:///C:/Users/Hossein/AppData/Local/Temp/temp.htm 02-May-19