Vous êtes sur la page 1sur 3

-> start /CMM/faultmgmt/shell

Are you sure you want to start /CMM/faultmgmt/shell (y/n)? y

faultmgmtsp> fmadm faulty


------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2015-12-21/14:18:27 5b1a918a-bfb5-6b50-a076-edb47bedff1f SPX86-8000-1D Critical

Fault class : fault.chassis.device.fail

FRU : /CH/BL0
(Part Number: 541-4197-06)
(Serial Number: 1005LCB-1126D4037D)

Description : A device necessary to support a configuration is missing.

Response : The service required LED on the chassis will be illuminated.

Impact : The chassis may be powered down.

Action : The administrator should review the ILOM event log for
additional information pertaining to this diagnosis. Please
refer to the Details section of the Knowledge Article for
additional information.

------------------- ------------------------------------ -------------- --------


Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2015-12-21/14:19:52 4b28a367-202c-cdd9-caa5-c62d79753ed3 SPX86-8000-1D Critical

Fault class : fault.chassis.device.fail

FRU : /CH/BL1
(Part Number: 541-4197-06)
(Serial Number: 1005LCB-1126D4037E)

Description : A device necessary to support a configuration is missing.

Response : The service required LED on the chassis will be illuminated.

Impact : The chassis may be powered down.

Action : The administrator should review the ILOM event log for
additional information pertaining to this diagnosis. Please
refer to the Details section of the Knowledge Article for
additional information.

------------------- ------------------------------------ -------------- --------


Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2016-01-07/14:49:03 cb588c79-52ef-c164-c429-c1079091e600 SPX86-8000-1D Critical

Fault class : fault.chassis.device.fail

FRU : /CH/BL3
(Part Number: 541-4197-06)
(Serial Number: 1005LCB-1126D4037P)
Description : A device necessary to support a configuration is missing.

Response : The service required LED on the chassis will be illuminated.

Impact : The chassis may be powered down.

Action : The administrator should review the ILOM event log for
additional information pertaining to this diagnosis. Please
refer to the Details section of the Knowledge Article for
additional information.

faultmgmtsp>

...............................................................

-> cd /CMM/logs/event
/CMM/logs/event

-> show list

/CMM/logs/event/list
Targets:

Properties:

Commands:
cd
show

ID Date/Time Class Type Severity


----- ------------------------ -------- -------- --------
3399 Tue Jun 14 11:24:34 2016 Captive Shell Command Entered minor
Fault Management Shell Command Executed: exit
3398 Tue Jun 14 11:24:19 2016 Captive Shell Command Entered minor
Fault Management Shell Command Executed: fmadm
3397 Tue Jun 14 11:21:36 2016 Captive Shell Command Entered minor
Fault Management Shell Command Executed: fmadm
3396 Tue Jun 14 11:12:35 2016 Audit Log minor
root : Open Session : object = "/CMM/session/type" : value = "shell" : su
ccess
3395 Fri May 27 08:46:31 2016 IPMI Log critical
ID = 4c7 : 05/27/2016 : 08:46:31 : OEM sensor : BL3/ERR : Predictive Fai
lure Asserted
3394 Wed Mar 16 11:24:18 2016 IPMI Log critical
ID = 4c6 : 03/16/2016 : 11:24:18 : OEM sensor : BL3/ERR : Predictive Fai
lure Asserted
3393 Thu Mar 10 13:02:37 2016 IPMI Log minor
ID = 4c5 : 03/10/2016 : 13:02:37 : Module/Board : BL1/STATE : Transition
to Running
3392 Thu Mar 10 13:00:36 2016 Audit Log minor
root : Close Session : object = "/CMM/session/type" : value = "shell" : s
uccess
3391 Thu Mar 10 11:44:55 2016 IPMI Log minor
ID = 4c4 : 03/10/2016 : 11:44:55 : Module/Board : BL1/STATE : Transition
to Power Off
3390 Thu Mar 10 11:43:08 2016 Audit Log minor
root : Set : object = "/CH/BL1/SYS/power_state" : value = "soft" : succes
s
Paused: press any key to continue, or 'q' to quit

-> pwd
Current default target: /CMM/logs/event

-> set clear=true


Are you sure you want to clear /CMM/logs/event (y/n)? y
Set 'clear' to 'true'

->

logon on to the server and type:

fmadm faulty