NPT +20.80
CUADRO DE COLUMNAS
W
0.25
0.25
Ø3/8", 1@0.05, 6@0.10, RTO @0.20m
OCTAVO
0.65
1.00
0.80
1.00
1.00
0.85
0.85
NIVEL
0.75
0.75
0.75
NPT +18.20
0.25
0.25
NIVEL
0.65
al
1.00
0.80
1.00
1.00
0.85
0.85
0.75
0.75
0.75
2.30
7°
7º N
Ø3/8", 1@0.05, 6@0.10, RTO @0.20m
NIVEL
6 Ø 5/8"+ 6 Ø 5/8"+ 4 Ø 5/8"+ 2 Ø 5/8"+ 4 Ø 5/8"+ 12 Ø 5/8"+ 10 Ø 5/8"+ 2 Ø 5/8"+
8 Ø 3/4" 4 Ø 3/4" 8 Ø 3/4" 8 Ø 3/4" 10 Ø 3/4" 12 Ø 3/4" 16 Ø 3/4" 10 Ø 3/4"
0.25
0.25
0.50 VIGA VIGA
4 Ø3/8" @0.10
NIVEL
0.65
al
1.00
0.80
1.00
1.00
0.85
0.85
0.75
0.75
0.75
5°
NIVEL
6 Ø 5/8"+ 6 Ø 5/8"+ 4 Ø 5/8"+ 2 Ø 5/8"+ 12 Ø 5/8"+ 10 Ø 5/8"+ 2 Ø 5/8"+
4 Ø 5/8"+
8 Ø 3/4" 4 Ø 3/4" 8 Ø 3/4" 8 Ø 3/4" 10 Ø 3/4" 12 Ø 3/4" 16 Ø 3/4" 10 Ø 3/4"
Ø3/8", 1@0.05, 6@0.10, RTO @0.20m
2.30
6º N
VIVIENDA MULTIFAMILIAR
ESPECIFICACIONES TECNICAS BÁSICAS
1.0 CIMENTACION
Profundidad de la cimentación 3.00 m por debajo del nivel N.P.T. 7.0 LONGITUD DE EMPALME EN COLUMNAS
CUADRO DE ZAPATAS
NPT +13.00
Capacidad portante de servicio (estudio 1.05 Kg/cm2
de Suelos Ing. Alfredo Gaspar Apaza CIP. Cuando se empalma una columna, lo ideal es hacerlo en los dos tercios centrales
128571 (empalme A). Sin embargo, a veces se empalman en la parte inferior de la columna
(empalme B y C), lo que no es recomendable ya que debilita esa sección. En el caso
Le
L/3 L/3 L/3
Le Le h
L/4 L/4 L/4 L/4
DIAMETRO DE LA
H/3
Ø 1/4" Ø 3/8" Ø 1/2" Ø 5/8" Ø 3/4" Ø 1"
VARILLA DE ACERO
NPT +10.40 La 0.25 m 0.35 m 0.45 m 0.55 m 0.70 m 1.15 m
BARRAS DEL
LECHO SUPERIOR Le (+) 0.30 m 0.40 m 0.60 m 0.75 m 0.90 m 1.50 m H H/3 Le BLOQUETAS 30*15*20
BARRAS DEL La 0.20 m 0.20 m 0.30 m 0.35 m 0.45 m 0.55 m
0.50 VIGA VIGA LECHO INFERIOR Le 0.25 m 0.30 m 0.40 m 0.50 m 0.60 m 0.75 m
1 Ø 3/8"
Ast 1Ø 1/4"@ 0.25m.
4 Ø3/8" @0.10
H/3 1.7*Le
(+) USAR PARA EMPALMES DEL REFUERZO VERTICAL EN COLUMNA.
SÍ EL PORCENTAJE DE EMPALME EN LA MISMA SECCIÓN SUPERA EL 30%,
0.05
ENTONCES INCREMENTAR LA LONGITUD DE EMPALME EN 60%.
5.0 LONGITUD RECTA DE GANCHOS DE ESTRIBOS CERRADOS
a
0.20 0.15
DIAMETRO a (cm)
8.0 OBSERVACION GENERAL
Ø 8 mm 7.5 45
Ø 3/8" 10
Ø Estas especificaciones técnicas básicas deben complementarse con las
prescripciones del Reglamento Nacional de Edificaciones y de sus normas técnicas 0.30 0.30
correspondientes. 1 Ø 3/8" 1 Ø 3/8" 1 Ø 3/8"
Ø3/8", 1@0.05, 6@0.10, RTO @0.20m
2.30
4º N
1,550
1Ø1/2"@ 0.20 1Ø1/2"@ 0.20
1Ø3/8"@ 0.20
1,200
PROYECTO:
1Ø1/2"@ 0.20 1Ø1/2"@ 0.20
2.30
Ø 1/2'' @ 0.20
3º N
1Ø3/8"@ 0.20
0.30
NPT +5.20
0.186
DETALLE DE PLACA ASCENSOR
ESCALA: 1/25
0.50 VIGA VIGA
4 Ø3/8" @0.10
Ø3/8", 1@0.05, 6@0.10, RTO @0.20m
PLANO DE ESCALERAS
ESCALA: 1/25
2.30
2º N
NPT +2.60
CIMIENTO: CONCRETO F`C=140 KG/CM2 + 60% PIEDRA GRANDE 6" MAXIMO Z = 0.3 U = 1.5 S = 1.2 (SUELO TIPO S2) TP = 0.6
SOBRECIMIENTO: CONCRETO F`C=140 KG/CM2 + 30% PIEDRA MEDIANA 3" MAXIMO
VIGA VIGA R=8 C=2.5 (TP/T) 1.25< 2.5
0.50 RESISTENCIA DE TERRENO: 1.20 Kg/cm2
4 Ø3/8" @0.10
DEZPLAMIENTO MAXIMO : 2.65 cm
CONCRETO - ZAPATAS fc = 210 kg/cm2 DEZPLAMIENTO CALCULADO : 0.12 cm
CONCRETO - COLUMNAS fc = 210 kg/cm2
CONCRETO - VIGAS fc = 210 kg/cm2
Ø3/8", 1@0.05, 6@0.10, RTO @0.20m
1º N SUELO FUNDACIÓN
2.30 SE EMPLEARA UN MORTERO PARA LADRILLOS KING KONG DE f'm = 35 Kg/cm2 DE CAPACIDAD ADMISIBLE : 1.70 Kg/cm2
1:4 DE CEMENTO: ARENA; LLENANDO COMPLETAMENTE LAS JUNTAS VERTICALES Y
HORIZONTALES. EN DILATACION e=1" (USAR TECNOPORT). Nota: Verificar la resistencia del suelo en obra
EL LADRILLO SERA DE 0.09x0.13X0.24 m. CON F'b=90kg/cm2 DEL TIPO III,
RESISTENCIA A LA COMPRESION DE 280 kg/cm2
Plano:
NPT 0.00
DETALLE DE COLUMNAS
1er - 8vo Nivel
Ø3/8" @0.15
Propietario:
Ubicación:
A.P.V. Huayna Picol Lte. M-7 calle 06
Datos Generales:
Escala: INDICADA EN LA LAMINA
Fecha: CUSCO FEBRERO DEL 2017
Ø5/8" @0.20 Ø5/8" @0.20
CAD: :::G::M::V::H:::
0.80
0.30
FALSA Z APATA
F'c=100Kg/cm2
e=0.30m.