Vous êtes sur la page 1sur 3

What is DAO No. 35 Series of 1990 all about?

A. Revised Effluent Regulation of 1990


B. Revised Water Usage/Classification Water Quality Criteria
C. Phil. National Standard for Effluent Discharge 2007
D. Phil. National Standard for Drinking Water 2007

Ans. A
Black steel pipe with galvanized malleable fitting is ideal for?
A. oxygen pipe
B. electrical conduit
C. gas pipe
D. water Pipe
Ans. C

Opening use to received pipes?


A. vertical shaft
B. pipe chase
C. ducts
D. raceway
Ans. B
What is the minimum trap seal?
A. 1.5"
B. 2"
C. 2.5"
D. 3"
Ans. B
Accessibility Law of the Philippines is ____?
A. BP 200
B. BP 344
C. BP 433
D. BP 220
Ans. B
Alternative to the conventional septic tank?
A. aerobic treatment system
B. cistern
C. STP
D. landfill

Ans. A
What can be discharge directly to sewer system?
A. building sewer
B. oil and grease
C. storm water
D. grey water

Ans. A
The retention period or the time for which suspended matters in septic tank would settle and stabilize is:
a. 24 hours
b. 12 hours
c. 18 hours
d. 30 hour
Ans. A
An individual vent for a plumbing fixture located at the downstream of a trap?
A. vent pipe
B. back vent
C. branch vent
D. vent through roof

Ans. B
Which plumbing fixture does not have a water-saving feature?
A. lavatory with pop-up
B. 1.5 gallon flush water closet
C. flow limiting feature
D. waterless urinal
Ans, B

1 carat equivalent of ________?


Ans. 0.20g

Bacteria which has no function in sewage treatment


a. Non- aerobic bacteria
b. Pathogenic bacteria
c. Facultative bacteria
d. Aerobic bacteria

Ans. C

Saddle clamp is a pipe fitting which is not use


when water service is to be interconnected to the type of water main.
a. Centrifugal cast iron pipe
b. Asbestos cement pipe
c. Galvanized iron pipe
d. PVC pipe
Ans B

According to Accessibility Law, urinals shall be of the wall hung and should have an elongated lip; the maximum
height of the lip should ___ from the toilet floor.
A. 400 mm
B. 700 mm
C. 480 mm
D. 600 mm
Ans. C
Basic Principles listed in RNPCP 1999 was based on what section of RA
1378?
A. Sec. 2
B. Sec. 3
C. Sec. 4
D. Sec. 5
Ans. C

Any branch more than _____meter in length shall be separately vented in an approved manner.
a. 1.50
b. 2.60
c. 3.60
d. 4.60

Ans. A

According to Accessibility Law, the maximum height of toilet seat for persons with disabilities is ____?
A. 450 mm
B. 500 mm
C. 400 mm
D. 425 mm
Ans. A
what do you call the undesirable type of vegetation formed when water reservoir is exposed to light?
a.septic scum
b.sledge
c.pond scum
d.floe
Ans. C
A drain connecting one or more fixtures to a solid or waste stack?
A. combined drain
B. floor drain
C. circuit drain
D. branch drain
Ans. D