SINUMERIK
Method of delivery and
loading the EPLAN Add-in 3
SINUMERIK 840D sl / 828D
SINUMERIK Integrate Create Siemens DQ-Topo and
submenus 4
MyConfig - EPLAN Electric P8 Add-
In Configuring with EPLAN Add-
Operating Manual
In 5

EPLAN adaptations 6

DRIVE-CLiQ types 7

Messages 8

List of abbreviations A

Valid for:
CMC software version 4.8

12/2017
A5E43099659B-AA
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.

DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.

CAUTION
indicates that minor personal injury can result if proper precautions are not taken.

NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified
personnel are those who, based on their training and experience, are capable of identifying risks and avoiding
potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:

WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.

Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in
this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AG A5E43099659B-AA Copyright © Siemens AG 2017.


Division Digital Factory Ⓟ 12/2017 Subject to change All rights reserved
Postfach 48 48
90026 NÜRNBERG
GERMANY
Preface

SINUMERIK documentation
The SINUMERIK documentation is organized into the following categories:
● General documentation/catalogs
● User documentation
● Manufacturer/service documentation

Additional information
You can find information on the following topics at the following address (https://
support.industry.siemens.com/cs/de/en/view/108464614):
● Ordering documentation/overview of documentation
● Additional links to download documents
● Using documentation online (find and search in manuals/information)
If you have any questions regarding the technical documentation (e.g. suggestions,
corrections), please send an e-mail to the following address
(mailto:docu.motioncontrol@siemens.com).

mySupport/Documentation
At the following address (https://support.industry.siemens.com/My/ww/en/documentation),
you can find information on how to create your own individual documentation based on
Siemens' content, and adapt it for your own machine documentation.

Training
At the following address (http://www.siemens.com/sitrain), you can find information about
SITRAIN (Siemens training on products, systems and solutions for automation and drives).

FAQs
You can find Frequently Asked Questions in the Service&Support pages under Product
Support (https://support.industry.siemens.com/cs/de/en/ps/faq).

SINUMERIK
You can find information about SINUMERIK at the following address (http://www.siemens.com/
sinumerik).

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 3
Preface

Target group
This publication is intended for machine operators using EPLAN.
There is also basic information for administrators who, for example, install EPLAN Add-In.

Benefits
A SINAMICS topology configured in EPLAN can be used in Create MyConfig Topo.
The SINAMICS topology is exported to EPLAN electric P8 as a file via the "Siemens DQ-Topo"
Add-In. This output file is imported for further use in Create MyConfig Topo. The data already
configured for the production of a machine can therefore continue to be used with immediate
effect in CMC.

Purpose of the document


This document describes the use of the EPLAN Add-In "Siemens DQ-Topo".

Standard scope
This documentation only describes the functionality of the standard scope. Additions or
revisions made by the machine manufacturer are documented by the machine manufacturer.
Other functions not described in this documentation might be executable in the control. This
does not, however, represent an obligation to supply such functions with a new control or when
servicing.
Furthermore, for the sake of clarity, this documentation does not contain all detailed information
about all product types and cannot cover every conceivable case of installation, operation or
maintenance.

Technical Support
Country-specific telephone numbers for technical support are provided in the Internet at the
following address (https://support.industry.siemens.com/sc/ww/en/sc/2090) in the "Contact"
area.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


4 Operating Manual, 12/2017, A5E43099659B-AA
Table of contents

Preface.........................................................................................................................................................3
1 Safety notes..................................................................................................................................................7
1.1 Fundamental safety instructions..............................................................................................7
1.1.1 General safety instructions.......................................................................................................7
1.1.1.1 Danger to life if the safety instructions and residual risks are not observed............................7
1.1.1.2 Malfunctions of the machine as a result of incorrect or changed parameter settings..............7
1.1.2 Warranty and liability for application examples........................................................................7
1.1.3 Industrial security.....................................................................................................................8
2 Requirements...............................................................................................................................................9
3 Method of delivery and loading the EPLAN Add-in....................................................................................11
3.1 Method of delivery..................................................................................................................11
3.2 Loading the EPLAN Add-In....................................................................................................12
4 Siemens DQ-Topo and submenus.............................................................................................................15
5 Configuring with EPLAN Add-In.................................................................................................................17
5.1 Requirement...........................................................................................................................17
5.2 Settings..................................................................................................................................17
5.2.1 SINAMICS product catalog....................................................................................................17
5.2.2 Setting the path for the drive object list..................................................................................18
5.2.3 Defining unknown devices.....................................................................................................19
5.2.4 DRIVE-CLiQ configuration.....................................................................................................22
5.3 Define bus data......................................................................................................................22
5.3.1 Control master (NCU)............................................................................................................24
5.3.2 Expansion modules of the control..........................................................................................27
5.4 Assigning drive objects..........................................................................................................28
5.4.1 EPLAN devices......................................................................................................................28
5.4.2 Drive object list.......................................................................................................................29
5.4.3 Assignment of the DO component to the device component.................................................30
5.4.3.1 Assignment using drag-and-drop...........................................................................................30
5.4.3.2 Assignment via direct input....................................................................................................30
5.4.4 Filtering of EPLAN devices and drive objects........................................................................31
5.5 Exporting the DRIVE-CLiQ topology......................................................................................32
5.5.1 Requirement...........................................................................................................................32
5.5.2 Exporting the DRIVE-CLiQ topology......................................................................................33
5.6 Excluding devices from the export.........................................................................................34
5.7 Command line interface.........................................................................................................36
6 EPLAN adaptations....................................................................................................................................37
6.1 Settings via "Siemens DQ-Topo" add-in................................................................................37

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 5
Table of contents

6.2 Minimum requirements in EPLAN regarding DRIVE-CLiQ topology......................................37


6.3 Minimum requirements in EPLAN regarding power topology................................................38
7 DRIVE-CLiQ types......................................................................................................................................41
8 Messages...................................................................................................................................................43
8.1 Drive objects..........................................................................................................................43
8.2 Errors.....................................................................................................................................43
8.3 Warnings................................................................................................................................45
A List of abbreviations....................................................................................................................................47
Index...........................................................................................................................................................49

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


6 Operating Manual, 12/2017, A5E43099659B-AA
Safety notes 1
1.1 Fundamental safety instructions

1.1.1 General safety instructions

1.1.1.1 Danger to life if the safety instructions and residual risks are not observed

WARNING
Danger to life if the safety instructions and residual risks are not observed
If the safety instructions and residual risks in the associated hardware documentation are not
observed, accidents involving severe injuries or death can occur.
● Observe the safety instructions given in the hardware documentation.
● Consider the residual risks for the risk evaluation.

1.1.1.2 Malfunctions of the machine as a result of incorrect or changed parameter settings

WARNING
Malfunctions of the machine as a result of incorrect or changed parameter settings
As a result of incorrect or changed parameterization, machines can malfunction, which in turn
can lead to injuries or death.
● Protect the parameterization (parameter assignments) against unauthorized access.
● Handle possible malfunctions by taking suitable measures, e.g. emergency stop or
emergency off.

1.1.2 Warranty and liability for application examples


The application examples are not binding and do not claim to be complete regarding
configuration, equipment or any eventuality which may arise. The application examples do not
represent specific customer solutions, but are only intended to provide support for typical tasks.
You are responsible for the proper operation of the described products. These application
examples do not relieve you of your responsibility for safe handling when using, installing,
operating and maintaining the equipment.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 7
Safety notes
1.1 Fundamental safety instructions

1.1.3 Industrial security

Note
Industrial security
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens products and solutions only represent one component of such a
concept.
The customer is responsible for preventing unauthorized access to its plants, systems,
machines and networks. Systems, machines and components should only be connected to
the enterprise network or the internet if and to the extent necessary and with appropriate
security measures (e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into
account. For more information about industrial security, please visit:
Industrial security (http://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more secure.
Siemens strongly recommends to apply product updates as soon as available and to always
use the latest product versions. Use of product versions that are no longer supported, and
failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed at:
Industrial security (http://www.siemens.com/industrialsecurity).

WARNING
Unsafe operating states resulting from software manipulation
Software manipulations (e.g. viruses, trojans, malware or worms) can cause unsafe operating
states in your system that may lead to death, serious injury, and property damage.
● Keep the software up to date.
● Incorporate the automation and drive components into a holistic, state-of-the-art industrial
security concept for the installation or machine.
● Make sure that you include all installed products into the holistic industrial security concept.
● Protect files stored on exchangeable storage media from malicious software by with
suitable protection measures, e.g. virus scanners.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


8 Operating Manual, 12/2017, A5E43099659B-AA
Requirements 2
In order to be able to use the EPLAN Add-In, you require the EPLAN functionality of the "API
AddIns" interface.

EPLAN versions
This documentation applies to the EPLAN Add-In version V1.9.
The EPLAN Add-In has been released for EPLAN electric P8 versions 2.3, 2.4 and 2.5.
The functionality of the Add-In is identical in all EPLAN versions. The only exception is the
definition of the PLC bus properties. The differences in the definition of the bus properties are
in the EPLAN software.

SINAMICS product catalog


The SINAMICS product catalog must be available and loaded. For further information on
settings, refer to Section "SINAMICS product catalog" (Page 17).
A current version of the SINAMICS product catalog will be delivered with the EPLAN Add-In.
When unpacking "EPlanPlugin.zip", the catalog is stored in the default directory.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 9
Requirements

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


10 Operating Manual, 12/2017, A5E43099659B-AA
Method of delivery and loading the EPLAN Add-in 3
3.1 Method of delivery
The EPLAN Add-In is delivered as a ZIP file "EPlanPlugin.zip" with the DVD for Create
MyConfig from version 4.8.
To load in EPLAN, unpack the EPLAN Add-In ZIP file in a directory of your choice.

Requirement
You require two licenses to use the EPLAN Add-In:
● One license to load and use the EPLAN Add-In in the platform "EPLAN Electric P8" and
create the export file from EPLAN.
● A further license to import the export file from EPLAN with the DRIVE-CLiQ topology to
Create MyConfig Topo.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 11
Method of delivery and loading the EPLAN Add-in
3.2 Loading the EPLAN Add-In

3.2 Loading the EPLAN Add-In


The EPLAN Add-In is loaded via the "EPLAN Electric P8" platform.
1. Select "Utilities" > "API add-ins..." via the main menu.

Figure 3-1 EPLAN - Loading the Add-In

2. The "API modules (assemblies)" dialog opens.


3. Click the "Load" button.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


12 Operating Manual, 12/2017, A5E43099659B-AA
Method of delivery and loading the EPLAN Add-in
3.2 Loading the EPLAN Add-In

4. Select the file "Siemens.EplAddIn.DQTopo.dll" from the directory into which you unpacked
the EPLAN Add-In.

Figure 3-2 EPLAN dialog "API modules (assemblies)"

5. Confirm with "OK".


Once you have successfully loaded the EPLAN Add-In, the "Siemens DQ-Topo" main menu
is displayed.

Figure 3-3 New "Siemens DQ-Topo" main menu

Loading the EPLAN Add-In using the command line


You will find information on how start the EPLAN Add-In using a command line in the Section
"Command line interface" (Page 36).

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 13
Method of delivery and loading the EPLAN Add-in
3.2 Loading the EPLAN Add-In

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


14 Operating Manual, 12/2017, A5E43099659B-AA
Siemens DQ-Topo and submenus 4
The "Siemens DQ-Topo" main menu has the following submenus:

Figure 4-1 "Siemens DQ-Topo" main menu

Further information on submenus is available under:


● Assigning drive objects (Page 28)
● Settings… (Page 17)
– SINAMICS product catalog (Page 17)
– DO list (Page 18)
– Device settings (Page 19)
– DRIVE-CLiQ type settings (Page 22)

Figure 4-2 "Settings..." dialog

● Export (Page 32)

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 15
Siemens DQ-Topo and submenus

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


16 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In 5
5.1 Requirement
Before exporting the configuration, check the following points in EPLAN:
● Make sure that the EPLAN article database has been filled with additional information, e.g.
DRIVE-CLiQ type of devices
You will find further information on this in Section DRIVE-CLiQ configuration (Page 22).
● Configure the bus data for the master modules.
You will find further information in Section Defining bus data (Page 22).
● Make sure that the drive objects (DO) have been assigned.
You will find further information in Section Assigning drive objects (Page 28).

5.2 Settings

5.2.1 SINAMICS product catalog


The storage location of the used SINAMICS product catalog can be set. You can specify the
path via "Siemens DQ-Topo" > "Settings...".
Per default, the catalog is stored in the "SinamicsKompKatalogFilter" subdirectory when the
EPLAN Add-In is installed.
The file name is "SINAMICS-DQ-Komponenten-Katalog.xml".

Figure 5-1 SINAMICS product catalog

Note
A valid catalog path is indicated by a red border to the path.

The current catalog version is displayed via the "Display catalog version" button.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 17
Configuring with EPLAN Add-In
5.2 Settings

Import the catalog


If you click the "Import catalog" button in the "Settings" dialog, you automatically set the DRIVE-
CLiQ type in the EPLAN article database for all SIEMENS devices defined in catalog.
A log file is generated during the import operation in which the errors are logged.
The "import-catalog.log.xml" file is located next to the "Siemens.EplAddIn.DQTopo.dll" EPLAN
Add-In.
After completing the import, the results are displayed in a dialog.

Figure 5-2 Results of the catalog import

5.2.2 Setting the path for the drive object list


You can specify the path for the drive object list via "Siemens DQ-Topo" > "Settings...".
You have the following options to set the path at "DO list" in the "Settings…" dialog.
● Project path as output path (relative path)
● Setting an absolute path

Figure 5-3 Settings - path to the DO list

Note
Take the "*.uvdx" file extension into account
The DO list has the "*.uvdx" file extension.
If the path for the DO list has an incorrect file extension, this is indicated by a red border to the
path.
Please note that a data type will be saved even if it is incorrect.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


18 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.2 Settings

Setting the project path as output path


If you want to use the project directory as output path for the DO list:
1. Activate the "Using project directory as output directory" checkbox.
After activation, an additional placeholder is set in front of the path of the DO list.

Figure 5-4 DO list: Project directory as output path

2. Enter the path to the DO list manually starting from the project directory.

Setting an absolute path


If you want to set an absolute path for the DO list, proceed as follows:
1. Set an absolute path at "DO list" in the "Settings…" dialog if the "Using project directory as
output directory" checkbox is deactivated.
2. Select the path and the required Drive object list via the button.

5.2.3 Defining unknown devices


Unknown devices are devices from third-parties or SIEMENS devices that are not defined in
the catalog.
These devices are defined at "Device settings" in the "Settings..." dialog so that they can be
detected and derived from the EPLAN Add-In.

Figure 5-5 "Settings…" dialog

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 19
Configuring with EPLAN Add-In
5.2 Settings

Procedure
Proceed as follows:
1. Click the "Define unknown devices" button.
The dialog with the same name opens.

Figure 5-6 "Define unknown devices" dialog: Creating device definitions

2. Enter the "Order number" of the device.


3. Select whether it is a motor or sensor in the drop-down list at "DRIVE-CLiQ type".

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


20 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.2 Settings

4. Specify the number of subcomponents.


Note
If the number of components is set to "0" when selecting the DRIVE-CLiQ type, the field
automatically becomes optional.
If the number of components is set to "1", e.g. for Sensor Modules, then a specification has
to be made as to whether this can be a "Single" or "Double" Sensor Module.
The number of components is only relevant for Sensor and Terminal Modules. For other
types, the number is set automatically to "0".
Two subcomponents of the same type are available for "Fail-safe Terminal Modules" or
"SMC40" and similar third-party devices.
5. The button opens a further dialog in which you can define the relevant connections of
the third-party device in detail.

Figure 5-7 "Define unknown devices": Connection list of a device definition

The connections to be defined are read from the SINAMICS product catalog based on
similar device types from SIEMENS.
Possible port types are:
– Analog for encoder connection
– DRIVE-CLiQ
– Current
After "Save and close" of the dialogs, including the "Settings…" main dialog, the EPLAN
article database is updated with the device types.

Note
Updating changes in the project
In order that the changed "Settings…" can be used in the available projects, the changes must
be compared to the EPLAN article database and then taken into the project.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 21
Configuring with EPLAN Add-In
5.3 Define bus data

5.2.4 DRIVE-CLiQ configuration


In the "Settings…" dialog at "DRIVE-CLiQ type settings", specify the mapping for the attributes
in the "EPLAN property" field.

Figure 5-8 Settings - DRIVE-CLiQ type settings

Predefined EPLAN properties


The following attributes are already mapped per default in the "EPLAN property" field:

Table 5-1 Settings mapped on "EPLAN properties"

Configuration option Description Predefined "EPLAN proper‐


ties"
Order number This attribute reads the order number for the article. If a Sie‐ Order number
mens article was determined based on the order number, the
ports apply as described in the following sections.
Device type This attribute determines the device type. Function group
The device type is required to determine the DQ topology.
If the device type is missing and a connection is made to a
DQ device type, an error message is issued.
Drive object - assignment The drive object assignment and the component assignment Additional field [1] – lan‐
are saved in this attribute. guage-neutral

5.3 Define bus data

Note
Take the EPLAN version into account
The EPLAN Add-In supports the evaluation and the export of the bus data as of EPLAN version
2.4.

Requirement

Take the following requirements into account:


● The bus data is configured in EPLAN for each connection.
● Set the display type of the connection to "Single-pole" so that you can enter the bus data
in the "Bus data" tab of the connection.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


22 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.3 Define bus data

● The device is considered from the viewpoint of EPLAN Add-In.


You will find further information on this in Section Requirement (Page 32).
● Always display the device as PLC unit.
● The connections with the corresponding bus data are exclusively of the "PLC connection
point and bus port" type.
● Only bus data of the "Profibus" and "Profinet" type is taken into account.
● The value of the EPLAN property "MasterSystemID" must be an integer.
● The EPLAN property "Position / Node ID" must be an integer. Use the "Position" instead
of the IP address for Profinet.

Note
Bus data - Internal/external PROFIBUS connection
Note that the bus data for the internal PROFIBUS connection of the NXs on the NCU is not
configured because it has already been permanently defined.
Configure the external PROFINET connection and the PROFINET interface.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 23
Configuring with EPLAN Add-In
5.3 Define bus data

Overview of the EPLAN bus data


Display and information in the "Properties (components): PLC connection points and bus ports"
dialog.

Figure 5-9 EPLAN Bus data

5.3.1 Control master (NCU)


Define the following bus data for the bus connections of the control master (NCU):
● Bus master / Bus coupler
● Bus system: Bus system type

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


24 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.3 Define bus data

● Position / Node ID: The position of the master on the respective bus.
● Property name "MasterSystemID": Bus number

Procedure

You define the bus data in the "Properties (components): PLC connection points and bus ports"
dialog > "Bus data" tab.
1. Select an object in EPLAN, e.g. a port.
2. Double-click the object. The "Properties (components): PLC connection points and bus
ports" dialog opens.
3. Select the "Bus data" tab.
4. Define the bus data. Information on this is provided in the following examples for the NCU
connections.
5. Confirm the changes via the "OK" button.

Configuring bus data for NCU


Examples are listed below on how you can configure the NCU with various connections.

Example of the NCU connection X126

Bus master / Bus coupler = e.g. "NCU-DP"


Bus system = "Profibus"
Position / Node ID = "2" (defined value)
MasterSystemID = "1" (defined value of the bus number)
Master ID Set; the checkbox is activated.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 25
Configuring with EPLAN Add-In
5.3 Define bus data

Figure 5-10 Example - configuring bus data for the NCU

Example of the NCU connection X136

Bus master / Bus coupler = e.g. "NCU-MPI/DP"


Bus system = "Profibus"
Position / Node ID = "2" (defined value)
MasterSystemID = "2" (defined value of the bus number)
Master ID Set; the checkbox is activated.

Example of the NCU connection X150 P1

Bus master / Bus coupler = e.g. "NCU-PN/IO"


Bus system = "Profinet"
Position / Node ID = e.g. "2"
MasterSystemID = e.g. "100" (value of the bus number)
Master ID Set; the checkbox is activated.

Note
X150 connections
Only one of the two "X150" connections has to be configured because logically they represent
the same PROFINET interface.
If both connections are configured, the configurations must match.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


26 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.3 Define bus data

5.3.2 Expansion modules of the control


Configure the expansion modules (slaves) and external CUs as follows:
● Bus master / Bus coupler: Use the same value as already defined for the master.
● Position / Node ID: Enter the "Slave address" or the "Slave position".
● Master ID: The checkbox remains deactivated because the "Master ID" will not be set.
The "MasterSystemID" is not configured because it is determined automatically. The value
defined on the master is used based on the value of the "Bus master / Bus coupler".

Figure 5-11 Example - external configuration - CU slave

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 27
Configuring with EPLAN Add-In
5.4 Assigning drive objects

5.4 Assigning drive objects


Start the function via the "Siemens DQ-Topo" > "Assign drive objects" main menu.

Figure 5-12 "Assign drive objects" dialog

The dialog is divided into two areas:


● The devices of the active EPLAN project with the valid DRIVE-CLiQ type are displayed on
the left-hand side.
You will find further information in Section "EPLAN devices" (Page 28).
● The Drive object list with the properties of the drive objects (DO) and the associated
components are displayed on the right-hand side.
You will find further information in Section "Drive object list" (Page 29).

5.4.1 EPLAN devices


The item designation, the DRIVE-CLiQ type and descriptive information are displayed for each
EPLAN device.
The information for SIEMENS devices is taken from the SINAMICS product catalog.
The component distribution according to the SINAMICS product catalog is displayed and
defined for each Siemens device. This includes the component index, type, information on
DRIVE-CLiQ and other ports.
You can find information on how you can integrate other unknown devices in the topology in
Section Defining unknown devices (Page 19).

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


28 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.4 Assigning drive objects

Additional information
An additional component of the "CU link" type is displayed for each expandable master module .

Note
Assign a drive object component to all components of a device.

Messages that refer to the component distribution and set DRIVE-CLiQ type of a device are
displayed below the device:

Figure 5-13 Assigning warnings and messages to drive objects - excerpt from "Assign drive objects"
dialog, left-hand side

5.4.2 Drive object list


The following criteria must be satisfied so that the DO list can be read:
● The DO list is in the current project directory.
● The DO list is called "topo.uvdx".
You will find further information in Section "Settings" under "Setting the path for drive object
list" (Page 18).

Figure 5-14 Structure of the DO list - excerpt from "Assign drive objects" dialog, right-hand side

All drive objects (DO) are listed on the first level. When a DO is selected, the associated
components are listed.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 29
Configuring with EPLAN Add-In
5.4 Assigning drive objects

5.4.3 Assignment of the DO component to the device component

5.4.3.1 Assignment using drag-and-drop


You can assign a DO component to a device component using drag-and-drop.
DO components have to be assigned to EPLAN device components for CMC. This assignment
can be performed in EPLAN or subsequently in CMC.
Select the DO components from the DO list on the right-hand side in the "Assign drive objects"
window so that you can assign them on the left-hand side of the EPLAN device components.

The following is an "NCU710" example:

Figure 5-15 Assigning DO components to device components in EPLAN by drag-and-drop

1. Select the required drive object (DO) in the "Assign drive objects" window on the right-hand
side.
2. Click "DO name".
The component list belonging to the DO opens.
3. Select the required DO component and drag it to the required component line below the
device on the left-hand side
The "Assigned drive object" and the "Assigned component" are displayed immediately.
4. After completing the assignment, you can confirm the changes via the "Apply" or "Save and
close" button or reject them with the "Cancel" button.
When the assignment has been accepted, the DO name and the component name are
displayed in the preconfigured EPLAN property field for the appropriated devices.
DO and component are displayed separated by a ">", e.g. "NCU710>NCU_01". If there are
a number of subcomponents, they are separated by a semicolon.
5. If you want to delete an assignment, select the appropriate line of the device component
and delete it via the "Del" key.
6. If you what to delete all assignments of a drive object, select the drive object and press the
"Del" key.

5.4.3.2 Assignment via direct input


You can also enter the DO component of a device component directly via the provided property
field instead of using drag-and-drop (Page 30).
You will find further information on the standard use of the "EPLAN property" field in Section
"Minimum requirements in EPLAN regarding DRIVE-CLiQ topology" (Page 37).

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


30 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.4 Assigning drive objects

Entries in the EPLAN property fields


Note the following rules for entries in the EPLAN property fields:
● The DO variable is included in the DO list.
● The ">" separator must be used for the separation of the DO name and the DO component.
● Note the following XML rules when assigning DO variables:

Character XML
< &lt;
> &gt;
& &amp;
" &quot;
' &apos;

● If the DO name includes the ">" separator, enter it as previously defined in the table.

DO assignment using the MOTOR example with precisely one DO assignment:


"DMM_2>Mot_02"
Display: DO + motor

DO assignment using the MOTOR_WITH_ENCODER example with two DO assignments:


"DMM_1>Mot_03>DMM_1>Enc_01"
Display: DO + motor + DO + encoder

5.4.4 Filtering of EPLAN devices and drive objects

Filtering of EPLAN devices


To filter according to EPLAN devices, you have the following options:
● Filtering according to unassigned devices
● Filtering based on the entered device designation

Figure 5-16 Filtering devices

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 31
Configuring with EPLAN Add-In
5.5 Exporting the DRIVE-CLiQ topology

Filtering of drive objects


To filter according to drive objects, you have the following options:
● Filtering via the specified DO name
● Via the entered DO type
● Via the entered DO number
● Via the entered name of the axis
● Via the entered comment on the drive object

Figure 5-17 Filtering drive objects

5.5 Exporting the DRIVE-CLiQ topology

5.5.1 Requirement
The equipment parts list forms the basis for export with the following requirements:
● Select precisely one function as main function for each item designation.
● Store at least one article for each main function.
● Define a DRIVE-CLiQ type.

Device connection name

The connection name is determined according to the following algorithm:


● Connector item designation property
● From the item designation of the connection function: The last section after the device item
designation is relevant; identified by the ":" or "-" separator.

Examples

=Plant+location item desig‐ → X100


nation:X100
=Plant+location item desig‐ → X1
nation-X1
=Plant+location item desig‐ → X100
nation DQ:X100
The device connection name for the export of the DRIVE-CLiQ topology is defined by the
SINAMICS product catalog or through the definition of an unknown device.
You can find further information about this in Section "Defining unknown devices" (Page 19).

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


32 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.5 Exporting the DRIVE-CLiQ topology

5.5.2 Exporting the DRIVE-CLiQ topology


You can export the DRIVE-CLiQ topology via the "Siemens DQ-Topo" > "Export" main menu.
This creates an export file from EPLAN. This export file is suitable for the further processing
of the drive system configuration.

Figure 5-18 Exporting the DRIVE-CLiQ topology

Note
Creating an export file
To create a complete export file, note that the following requirements must be satisfied:
● The drive objects have been assigned to the EPLAN devices
You will find information on this in Section Assigning drive objects (Page 28).
● The bus data has been configured
You will find information in Section Defining bus data (Page 22).

Creating an export file


To export the DRIVE-CLiQ topology, proceed as follows:
1. Select the required project.
2. With the option "Without/with DO list", you specify whether the DO list that has been used
is also exported.
3. Name the output file, whose file type is "*.sdx".
4. Click the "Export" button to perform the export.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 33
Configuring with EPLAN Add-In
5.6 Excluding devices from the export

5. A progress bar displays the currently performed operations.


6. After completing the export, a dialog displays the results of the export.

Figure 5-19 Export results

7. The "Open log file" button opens the log of the export operation.
8. You can correct any listed errors or warnings.
You will find further information on this in Section Messages (Page 43).

Note
"Without DO list" / "With DO list" options
With the "Without DO list" export, the DO assignment must be performed in Create MyConfig.
For this purpose, the DO list can also be read in separately in Create MyConfig Topo in addition
to the "*.sdx".
If the "With DO list" option is used for the export, the DO list must be under the set path and
must be valid. The DO list is then imported into Create MyConfig Topo.

5.6 Excluding devices from the export


Certain devices can be excluded from the export based on their display type.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


34 Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.6 Excluding devices from the export

Procedure
To exclude a device from the export, proceed as follows:
1. In the Add-In directory, open the file with the extension
"Siemens.EplAddin.DQTopo.dll.eplan.config".
This file is always automatically generated when a configuration is saved.
2. After opening the file, search for the appropriate key in the "ConfigurableFilterFunctions"
tag.

Figure 5-20 Example setting

3. Then set the Value of the appropriate Key to "true".

Figure 5-21 Example setting: Active filter for all-pole devices

EPLAN display type - key assignment


In the following table, the EPLAN display types have been assigned the appropriate keys:

EPLAN display type Key


All-pole Circuit
Overview Overview
Pair cross-reference PairCrossReference
Single-pole CircuitSingleLine
RI process picture ProcessAndInstrumentationDiagramm
External External
Graphic Graphics

Mapping of EPLAN display type and the keys

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 35
Configuring with EPLAN Add-In
5.7 Command line interface

5.7 Command line interface

Introduction
You can also start the EPLAN Add-In via a non-graphical user interface. The required
command line parameters are transferred via a console. With successful execution of the
action, the return value is "0".

Command syntax
The EPLAN command line interface has the following syntax:
$Path $GeneralParameters $ActionName $ProjectName $OutputFile
$ExportDOList

Placeholder Description Example


$Path EPLAN is called via the "W3u.exe" which is "C:\Program Files (x86)\EPLAN\Electric
located in the EPLAN directory. P8\2.4.4\Bin\W3u.exe"
$GeneralParameters For more detailed information and setting /NoSplash /Frame:0 /Auto /Quiet
options, refer directly to EPLAN.
$ActionName Name of the action to be executed. SiemensDQTopoExport
The name "SiemensDQTopoExport" has
been defined for the export by the EPLAN
Add-In.
$ProjectName Is available as parameter for the export ac‐ /PROJECTNAME:"C:\Users\Public\EPLAN\Data
tion in the form "/ParameterName:Parame‐ \projects\Company\EPLAN_project.elk"
terValue"
$OutputFile Is available as parameter for the export ac‐ /OUTPUTFILE:"C:\Windows\Temp\Test.sdx"
tion in the form "/ParameterName:Parame‐
terValue"
$ExportDOList Is available as parameter for the export ac‐ /EXPORTDOLIST:1
tion in the form "/ParameterName:Parame‐
terValue"
Parameter value Description
0 Without drive object list
1 With drive object list

Command line interface – parameter list

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


36 Operating Manual, 12/2017, A5E43099659B-AA
EPLAN adaptations 6
6.1 Settings via "Siemens DQ-Topo" add-in
The SINAMICS product catalog is selected and imported via the "Siemens DQ-Topo" add-in.
The entries in the EPLAN database can be changed for export of the DQ configuration.
You will find further information on this in Section "Settings (Page 17)".

6.2 Minimum requirements in EPLAN regarding DRIVE-CLiQ topology


The DRIVE-CLiQ topology describes the drive bus system. As with every bus system, the first
step is to define a master module.

Master modules
The DRIVE-CLiQ types (EPLAN database field) listed below are recognized as master
modules:

Table 6-1 Master modules

DRIVE-CLiQ type Description and examples


SIMOTION_CX Controller Extension for SIMOTION D4x5/D4x5-2
SINAMICS_CU Control Unit of SINAMICS S120, e.g. CU320/CU320-2
SIMOTION_CPU Control Unit/Controller of SIMOTION C/D/P
SIMOTION_CPU_C Controller of SIMOTION C
SIMOTION_CPU_D Control Unit of SIMOTION D with SINAMICS CU320/CU320-2 integrated
SIMOTION_CPU_P Control Unit of SIMOTION P
SINUMERIK_NCU Numerical Control Unit of SINUMERIK 840D/840Dsl/828D
SINUMERIK_NX Numerical Extension for SINUMERIK 840D/840Dsl/828D

Marking as a master module is specified via the DRIVE-CLiQ type entry.

Pre-defined DRIVE-CLiQ/encoder connection names

Pre-defined DRIVE-CLiQ connection names for SIEMENS devices:


● X100, X101, X102, X103, X104, X105
● X200, X201, X202, X203, X204, X205
● X400, X401, X402
● X500, X500/1, X500/2, X501, X502, X503, X504, X505

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 37
EPLAN adaptations
6.3 Minimum requirements in EPLAN regarding power topology

Pre-defined encoder connection names for SIEMENS devices:


● X100
● X520, X520/1, X520/2, X521, X531
● X261, X262, X2, Rail

Note
Evaluation error in DRIVE-CLiQ topology
If an error is recognized in the DRIVE-CLiQ topology, e.g. ring closure or duplicate wiring, the
sub-topology is not output as of the corresponding control unit (NX or NCU).

HLA modules
Note the following during configuration of HLA modules:
● The analog connection of the HLA valve, which is connected to the HLA module, must have
the name "X2".
● Represent the connection between the valve and the cylinder with standard power
connections. The name of the connection is "X1".

HF modules
Note the following during configuration of HF modules:
● Configure the cross rail between the sine filter and damping module using a power
connection. "Rail" is used as the connection name.
● As the cross rail between HF motor module and damping module is connected by DRIVE-
CLiQ, no further configuration is required.

6.3 Minimum requirements in EPLAN regarding power topology


The power topology describes the connections of the power supply of the modules and the
supply for the motors.

Predefined item designation for the port designation


The following predefined item designations for the port designation are recognized in EPLAN:
● DCN
● DCP
● IC
● L1
● X1, X2, X3, X4, X5

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


38 Operating Manual, 12/2017, A5E43099659B-AA
EPLAN adaptations
6.3 Minimum requirements in EPLAN regarding power topology

● S1
● T1

Note
Item designation that EPLAN does not recognize
There is no search for the following item designations:
● Item designation X24, +, M (Single Motor Module)
● X124, i.e. not a power supply connection for SINAMICS CPU in the export file "example.sdx"

Entering the "DeviceName" tag


When using a PLC unit as device representation, enter the tag "DeviceName" in the field "CPU:
Name [1]" under the tab "PLC structure data".

Figure 6-1 "PLC structure data" tab, entry for "CPU: Name [1]"

When using an ancillary equipment unit for device representation, enter the tag "DeviceName"
in the field "Function text" under the "Ancillary equipment unit" tab.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 39
EPLAN adaptations
6.3 Minimum requirements in EPLAN regarding power topology

Figure 6-2 "Ancillary equipment unit" tab, entry for "Function text"

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


40 Operating Manual, 12/2017, A5E43099659B-AA
DRIVE-CLiQ types 7
The possible DRIVE-CLiQ types are listed below.

DRIVE-CLiQ type Description and examples


SINAMICS_CU Control Unit of SINAMICS S120, e.g. CU320/CU320-2
SINUMERIK_NCU Numerical Control Unit of SINUMERIK 840D/840Dsl/828D
SINUMERIK_NX Numerical Extension for SINUMERIK 840D/840Dsl/828D
SINGLE_MOTOR_MODULE SINAMICS SMM
SINGLE_MOTOR_MODULE_HF SINAMICS High Frequency SMM
DOUBLE_MOTOR_MODULE SINAMICS DMM ENCODER
SENSOR_MODULE SINAMICS SMC30, SME25
VOLTAGE_SENSING_MODULE SINAMICS VSM
DAMPING_MODULE SINAMICS Damping Module
DAMPING_MODULE_HF SINAMICS High Frequency Damping Module
ADAPTER_MODULE SINAMICS AM600 of the SINAMICS S120M
DQ_EXTENSION DRIVE-CLiQ Extension of the SINAMICS S120M
HYBRID_CABINET_BUSHING SINAMICS S120M
CAPACITOR_MODULE SINAMICS Capacitor Module
ACTIVE_LINE_MODULE SINAMICS ALM
BASIC_LINE_MODULE SINAMICS BLM
SMART_LINE_MODULE SINAMICS SLM
ACTIVE_INTERFACE_MODULE SINAMICS AIM
POWER_SUPPLY_EXTERNAL SITOP PSU
POWER_SUPPLY_INTEGRATED SINAMICS CSM
COMMUNICATION_BOARD SINAMICS CBE30
TERMINAL_BOARD SINAMICS TB30
TERMINAL_MODULE SINAMICS TM54F, TM15
HUB_MODULE SINAMICS DMC20, DME20
SINAMICS_S120M Distributed Drive System = Motor + MM
SINAMICS_S120COMBI Drive System with 3/4 Combinated Drives
SINAMICS_S120COMBI3 Drive System with 3 Combinated Drives = 3xMM + 1xLM + 1xSM
SINAMICS_S120COMBI4 Drive System with 4 Combinated Drives = 4xMM + 1xLM + 1xSM
SMI SIMOTICS SMI
DQI SIMOTICS DQI
MOTOR_WITH_ENCODER motor with integrated encoder and analog cable to external sensor module
DQ_ENCODER SIMOTICS DQE

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 41
DRIVE-CLiQ types

DRIVE-CLiQ type Description and examples


SINE_WAVE_FILTER_HF HF Sine Filter Module
MOTOR_WITH_SENSOR_MOD‐ DQI- / SMI-Motor
ULE_AND_ENCODER* Cannot be used because EPLAN only permits a maximum of 30 characters in
the article database and the rest are cut.

* Further information on the maximum length of the EPLAN text fields can be found in the EPLAN help > "Find" tab:
"Article management: Field designations and field lengths of the article fields"

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


42 Operating Manual, 12/2017, A5E43099659B-AA
Messages 8
The EPLAN Add-In contains the following message types:
● Messages for Drive objects (Page 43)
● Errors (Page 43)
● Warnings (Page 45)
All messages are in alphabetical order in the respective list. The messages are described and
contain a remedy.

8.1 Drive objects


List of the possible drive objects for which feedback is available.
The drive objects are listed in alphabetical order according to name and are described.

Drive object name


Description Remedy
DEVICE_TYPE_IS_INVALID
The entered device type does not match the device type from Check and correct the device type.
the catalog. Alternatively, you can import the catalog and align the project.
DRIVEOBJECT_COMPONENT_ALREADY_ASSIGNED
When the assigned drive object or component name has Check and correct the assignments.
been assigned to several devices of components.
DRIVEOBJECT_COMPONENT_NOT_IN_GLOBALDO_LIST
When the assigned drive object or component name has not Check and correct the assignments.
been defined in the global DO list.
DRIVEOBJECT_IS_UNASSIGNED
When a component of the device does not have an assigned Assign the drive object and component name to each other.
drive object and/or component name.
ERR_GLOBAL_DO_LIST_NOT_FOUND
A global DO list is missing. Create a global DO list in the project directory.
Or copy a DO list to the project directory.

8.2 Errors
List of the possible errors for which feedback is available.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 43
Messages
8.2 Errors

The errors are listed in alphabetical order according to error designation and are described.

Error
Description Remedy
DEVICE_TYPE_IS_EMPTY
The DRIVE-CLiQ type of a device in the DRIVE-CLiQ topol‐ Define a valid DRIVE-CLiQ type.
ogy is empty.
Note
If the device is not part of a topology, then this message is
not an error.
DEVICE_TYPE_IS_UNDEFINED
The DRIVE-CLiQ type of a device in the DRIVE-CLiQ topol‐ Define a valid DRIVE-CLiQ type.
ogy has not been defined.
Note
If the device is not part of a topology, then this message is
considered to be a warning.
DRIVECLIQ_MULTIPLE_WIRING
Two devices have been connected several times to each oth‐ Delete one of the connections.
er in the DRIVE-CLiQ topology.
DRIVECLIQ_NO_MASTER_FOUND
A master module is missing in the DRIVE-CLiQ topology. Connect a master module (NCU).
DRIVEOBJECT_FILE_IS_EMPTY
The file with the global drive objects is empty. Provide either a valid file or no file.
DRIVEOBJECT_FILE_IS_INVALID
The file with the global drive objects is damaged or corrupt Provide either a valid file or no file.
and therefore cannot be read.
ERR_MULTIPLE_ALLOCATION_AT_DriveCLiQ_PORT
A DRIVE-CLiQ port has either been assigned or connected Delete one of the connections.
several times.
ERR_MULTIPLE_DriveCLiQ_MASTER
A DRIVE-CLiQ topology contains a number of master mod‐ ● Remove a master module from the topology.
ules (NCUs).
● Or split the topology into two topologies.
ERR_RING_TOPOLOGY
A DRIVE-CLiQ topology contains a ring connection. Break up the ring connection in the tree.
EXCEPTION_READING_BOM_ENTRY
An unexpected exception has occurred while reading the Please contact the Support with the listed exception.
EPLAN data for a device. The problem may not be able to resolved by the user.
EXCEPTION_READING_SYSTEMCONFIGURATION
The "SystemConfiguration.xml" file cannot be read. ● Check whether the rights for this file are available.
● Install the EPLAN Add-In again.
Note that the unknown devices must then be defined
again.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


44 Operating Manual, 12/2017, A5E43099659B-AA
Messages
8.3 Warnings

8.3 Warnings
List of the possible warnings for which feedback is available.
The warnings are listed in alphabetical order and are described.

Warnings
Description Remedy
BUS_DATA_IS_NOT_NUMERIC
The bus data has not been defined numerically. In the "Properties (components): PLC connection points and
bus ports", enter a numeric value in the "Bus data" tab in the
"Position / Node ID" data filed for the single-pole PLC con‐
nector.
BUS_SYSTEMID_IS_DIFFERENT
Two different PROFINET networks are defined at two con‐ Unify the PROFINET data.
nections of the device.
CONFIGURATION_COULD_NOT_READING / CONFIGURATION_UNAUTHORIZED_READING
The configuration could not be read. 1. Correct the authorization error.
2. Delete the configuration files and save them again.
CONFIGURATION_COULD_NOT_WRITING / CONFIGURATION_UNAUTHORIZED_WRITING
The configuration could not be written. 1. Correct the authorization error.
2. Delete the configuration files and save them again.
CONNECTION_HAS_SAME_DEVICE_ON_BOTH_ENDS
The connection goes to the same device. Change the connection to the correct device.
CONNECTION_NOT_HOMOGEN
The connection is between different types, e.g. DRIVE-CLiQ Change the connection.
to Power.
CONNECTION_TO_UNKNOWN_DEVICE
The connection goes to an unknown device. The signaled device is unknown:
● Because not listed in the SINAMICS product catalog
● Not defined as unknown device
● Because no order number available
● No DRIVE-CLiQ type defined
CONNECTION_TO_UNKNOWN_PORT
The connection goes to an unknown port. Change the connection.
Or define the device as unknown device in order to specify
the port name and the type.
You can find further information in Section "Defining unknown
devices" (Page 19).
DEVICE_EXISTS_MULTIPLE_TIME
The device has more than one EPLAN main function? Select one EPLAN function as main function.
DEVICE_NOT_IN_DRIVECLIQ_TOPOLOGY
The DRIVE-CLiQ device is not contained in the DRIVE-CLiQ Integrate the device in the DRIVE-CLiQ topology.
topology.
DEVICE_ONLY_IN_POWERTOPOLOGY
The DRIVE-CLiQ device is only integrated in the power top‐ Also integrate the device in the DRIVE-CLiQ topology.
ology.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 45
Messages
8.3 Warnings

Warnings
Description Remedy
DRIVEOBJECT_COMPONENT_ALREADY_ASSIGNED
The drive object (DO) has already been assigned to another Make a unique assignment of the drive object (DO).
device.
DRIVEOBJECT_COMPONENT_NOT_IN_GLOBALDO_LIST
The assigned drive object is not contained in the global DO Update the global DO list and adapt the assignment.
list.
DRIVEOBJECT_ERROR_WHILE_READING
An error occurred while reading the drive object assignments. The export will be continued without the relevant assignmens.
Contact the Support.
DRIVEOBJECT_FILE_HAS_DUPLICATE_IDS
Duplicates of DO names have been found in the global DO Remove the duplicates from the global DO list.
list.
The IDs in the global DO list are the DO names.
UNKNOWN_ECAD_VERSION
Bus data has not been implemented for the used EPLAN ver‐ Use a different EPLAN version or contact the Support.
sion.
UNSUPPORTED_PROPERTY_TYPE
The EPLAN property for bus data has found an unsupported Check the bus data or contact the Support.
type.
This warning can occur with unsupported EPLAN versions or
when unsupported values have been entered.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


46 Operating Manual, 12/2017, A5E43099659B-AA
List of abbreviations A
Item designation (EPLAN database field)
CMC Create MyConfig
CNC Computerized Numerical Control
CU Control unit
DO Drive object
NC Numerical control
NCU Numerical Control Unit (example: NCU 720.2)

Table A-1 File extensions for the file formats used in EPLAN

*.sdx SiemensDataExchange files - export file for Create MyConfig Topo


*.uvdx Extended DO list for Create MyConfig Topo

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 47
List of abbreviations

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


48 Operating Manual, 12/2017, A5E43099659B-AA
Index
CONNECTION_TO_UNKNOWN_DEVICE
Warning, 45
* CONNECTION_TO_UNKNOWN_PORT
Warning, 45
*.sdx, 33
Create MyConfig Topo
*.uvdx, 18
Without DO list, 34
Creating an export file, 33
CU, external
A Configuring, 27
Ancillary equipment unit
Device representation, 39
Assigning DO D
By drag-and-drop, 30
Device representation
Direct input, 30
Ancillary equipment unit, 39
Assigning drive objects
PLC unit, 39
Dialog, 28
DEVICE_EXISTS_MULTIPLE_TIME
Warning, 45
DEVICE_NOT_IN_DRIVECLIQ_TOPOLOGY
B Warning, 45
Benefits, 4 DEVICE_ONLY_IN_POWERTOPOLOGY
Bus data Warning, 45
Control master, 24 DEVICE_TYPE_IS_EMPTY
Defining, 24 Error, 44
EPLAN version, 22 DEVICE_TYPE_IS_INVALID
NCU, 24 Drive object, 43
Requirements, 22 DEVICE_TYPE_IS_UNDEFINED
Tab, 24 Error, 44
BUS_DATA_IS_NOT_NUMERIC Dialog
Warning, 45 Assigning drive objects, 28
BUS_SYSTEMID_IS_DIFFERENT Defining unknown devices, 20
Warning, 45 Export, 33
Settings, 15, 19
DO list, 29
C Project path as output path, 19
Setting an absolute path, 19
Command syntax, 36
Settings, 18
CONFIGURATION_COULD_NOT_READING
Drive object
Warning, 45
DEVICE_TYPE_IS_INVALID, 43
CONFIGURATION_COULD_NOT_WRITING
DRIVEOBJECT_COMPONENT_ALREADY_ASSI
Warning, 45
GNED, 43
CONFIGURATION_UNAUTHORIZED_READING
DRIVEOBJECT_COMPONENT_NOT_IN_GLOB
Warning, 45
ALDO_LIST, 43
CONFIGURATION_UNAUTHORIZED_WRITING
DRIVEOBJECT_IS_UNASSIGNED, 43
Warning, 45
ERR_GLOBAL_DO_LIST_NOT_FOUND, 43
CONNECTION_HAS_SAME_DEVICE_ON_BOTH_E
Drive objects
NDS
Assigning, 28
Warning, 45
filtering, 32
CONNECTION_NOT_HOMOGEN
DRIVE-CLiQ types
Warning, 45
List, 41

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 49
Index

DRIVECLIQ_MULTIPLE_WIRING ERR_MULTIPLE_DriveCLiQ_MASTER
Error, 44 Error, 44
DRIVECLIQ_NO_MASTER_FOUND ERR_RING_TOPOLOGY
Error, 44 Error, 44
DRIVEOBJECT_COMPONENT_ALREADY_ASSIG Error
NED DEVICE_TYPE_IS_EMPTY, 44
Drive object, 43 DEVICE_TYPE_IS_UNDEFINED, 44
Warning, 46 DRIVECLIQ_MULTIPLE_WIRING, 44
DRIVEOBJECT_COMPONENT_NOT_IN_GLOBALD DRIVECLIQ_NO_MASTER_FOUND, 44
O_LIST DRIVEOBJECT_FILE_IS_EMPTY, 44
Drive object, 43 DRIVEOBJECT_FILE_IS_INVALID, 44
Warning, 46 ERR_MULTIPLE_ALLOCATION_AT_DriveCLiQ_
DRIVEOBJECT_ERROR_WHILE_READING PORT, 44
Warning, 46 ERR_MULTIPLE_DriveCLiQ_MASTER, 44
DRIVEOBJECT_FILE_HAS_DUPLICATE_IDS ERR_RING_TOPOLOGY, 44
Warning, 46 EXCEPTION_READING_BOM_ENTRY, 44
DRIVEOBJECT_FILE_IS_EMPTY EXCEPTION_READING_SYSTEMCONFIGURA
Error, 44 TION, 44
DRIVEOBJECT_FILE_IS_INVALID Examples
Error, 44 NCU connection, 25
DRIVEOBJECT_IS_UNASSIGNED EXCEPTION_READING_BOM_ENTRY
Drive object, 43 Error, 44
EXCEPTION_READING_SYSTEMCONFIGURATIO
N
E Error, 44
Expansion modules
EPLAN
Configuring, 27
Article database, 18, 21
Export, 33
Bus data, 22
Equipment parts list, 32
Command line interface, 36
Device connection name, 32
Display type, 35
Equipment parts list, 32
F
Exporting the configuration, 17 File type
Keys assignment, 35 *.sdx, 33
Minimum requirements on DRIVE-CLiQ *.uvdx, 18
topology, 37 filtering
Minimum requirements on power topology, 38 Drive objects, 32
Text fields, 42 EPLAN device, 31
EPLAN Add-In
Loading, 12, 36
Siemens DQ-Topo, 4 H
Version, 9
HF modules
EPLAN device, 28
Configuration, 38
filtering, 31
HLA modules
EPLAN Electric P8, 12
Configuration, 38
Version,
EPLAN property, 22
ERR_GLOBAL_DO_LIST_NOT_FOUND
Drive object, 43
I
ERR_MULTIPLE_ALLOCATION_AT_DriveCLiQ_PO import-catalog.log.xml, 18
RT Item designation, 28
Error, 44 Predefined, 38

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


50 Operating Manual, 12/2017, A5E43099659B-AA
Index

topo.uvdx, 29

M
Main menu
U
Siemens DQ-Topo, 13, 15 UNKNOWN_ECAD_VERSION
Master modules Warning, 46
EPLAN database field, 37 UNSUPPORTED_PROPERTY_TYPE
MasterSystemID, 27 Warning, 46
Minimum requirements
Power topology, 38
V
Version
P EPLAN Add-In, 9
PLC unit EPLAN electric P8, 9
Device representation, 39
Predefined
DRIVE-CLiQ connection names, 37 W
Encoder connection names, 37
Warning
EPLAN property, 22
BUS_DATA_IS_NOT_NUMERIC, 45
Item designation, 38
BUS_SYSTEMID_IS_DIFFERENT, 45
Purpose of the document, 4
CONFIGURATION_COULD_NOT_READING, 45
CONFIGURATION_COULD_NOT_WRITING, 45
CONFIGURATION_UNAUTHORIZED_READING
R , 45
Requirement CONFIGURATION_UNAUTHORIZED_WRITING,
EPLAN versions, 9 45
SINAMICS product catalog, 9 CONNECTION_HAS_SAME_DEVICE_ON_BOT
H_ENDS, 45
CONNECTION_NOT_HOMOGEN, 45
S CONNECTION_TO_UNKNOWN_DEVICE, 45
CONNECTION_TO_UNKNOWN_PORT, 45
Settings
DEVICE_EXISTS_MULTIPLE_TIME, 45
Dialog, 15
DEVICE_NOT_IN_DRIVECLIQ_TOPOLOGY, 45
DO list, 18
DEVICE_ONLY_IN_POWERTOPOLOGY, 45
DRIVE-CLiQ type, 22
DRIVEOBJECT_COMPONENT_ALREADY_ASSI
Siemens DQ-Topo, 4, 13
GNED, 46
Submenus, 15
DRIVEOBJECT_ERROR_WHILE_READING, 46
Siemens.EplAddIn.DQTopo.dll, 18
DRIVEOBJECT_FILE_HAS_DUPLICATE_IDS,
Siemens.EplAddin.DQTopo.dll.eplan.config, 35
46
SINAMICS product catalog
RIVEOBJECT_COMPONENT_NOT_IN_GLOBAL
importing, 18
DO_LIST, 46
Path, 17
UNKNOWN_ECAD_VERSION, 46
Requirement, 9
UNSUPPORTED_PROPERTY_TYPE, 46
Version, 9
With DO list, 34
SINAMICS-DQ-Komponenten-Katalog.xml, 17
Without DO list, 34
Slave
Configuring, 27

T
Target group, 4

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In


Operating Manual, 12/2017, A5E43099659B-AA 51
Index