Vous êtes sur la page 1sur 4

Design office: INVENTION STEEL INDUSTRIES

Person in charge: YJT


Construction project: SQM-NIZWA
Number: 0811
Position: Date: 7/22/2014

Input data: Page 1 / 4

Concrete: Static loads


non-cracked concrete
concrete grade: C25/30 Tensile load:
Reinforcement: N Sd = 0.00 kN
normal or no reinforcement Shear load:
without edge reinforcement VxSd = 0.00 kN
Anchor bending: VySd = 2.50 kN
without anchor bending Moments:
MxSd = 7.70 kNm
MySd = 0.00 kNm
MzSd = 0.00 kNm

Eccentric load
e x = 0.0 mm
e y = 0.0 mm

Anchor plate:
x = 250 mm
y = 250 mm 7.70
l x1 = 35 mm
2. 5
l x2 = 35 mm 0

l y 1 = 35 mm
l y 2 = 35 mm z
sx1 sy 1
Distance between anchors:
cx1 y
s x1 = 180 mm h x
s y 1 = 180 mm 2
1 4
Edge distances:
3
c x1 = 110 mm
Thickness of base material:
h = 200 mm lx2
ly 1
sx1
sy 1
lx1 x
y ly 2

[ kN, kNm ]
Designed acc. to ETAG 001, Annex C
Wedge Anchor B A4 M16 hef80 Official approval ETA-01/0013: MKT B
Go ahead, design okay!
Design office: INVENTION STEEL INDUSTRIES
Person in charge: YJT
Construction project: SQM-NIZWA
Number: 0811
Position: Date: 7/22/2014

Page 2 / 4
Required proofs of tensile loads

Anchor loads:

Anchor 1 2 3 4
N Sd [kN] 19.11 19.11 0.00 0.00

Proof steel failure


h
N Sd ≤ N Rk,s / g Ms = N Rd,s Utilisation:
19.11 ≤ 88.00 / 1.50 = 58.67 32.6%

Proof pullout failure


Failure is not decisive.

Proof concrete cone failure


g
N Sd ≤ N Rk,c / g Mc = N Rd,c Utilisation:
38.21 ≤ 65.93 / 1.50 = 43.95 86.9%
o o
NRk,c A c,N A c,N Ys,N Yre,N Yec,N
2 2
39.58 kN 98400 mm 57600 mm 0.97 1.00 1.00

k1 h ef f ck,cube ccr,N e c1,N e c2,N


2
10.1 80 mm 30 N/m m 120.0 mm 0.0 mm 0.0 mm

Proof splitting failure


g
N Sd ≤ N Rk,sp / g Msp = N Rd,sp Utilisation:
38.21 ≤ 63.78 / 1.50 = 42.52 89.9%
o o
NRk,sp A c,sp A c,sp Ys,Sp Yre,Sp Yec,Sp Yh,Sp
2 2
33.00 kN 98400 mm 57600 mm 0.97 1.00 1.00 1.16

k1 h ef f ck,cube ccr,sp e c1,N e c2,N


2
10.1 80 mm 30 N/m m 120.0 mm 0.0 mm 0.0 mm

Designed acc. to ETAG 001, Annex C


Wedge Anchor B A4 M16 hef80 Official approval ETA-01/0013: MKT B
Go ahead, design okay!
Design office: INVENTION STEEL INDUSTRIES
Person in charge: YJT
Construction project: SQM-NIZWA
Number: 0811
Position: Date: 7/22/2014

Page 3 / 4
Required proofs of shear loads

Anchor loads:

Anchor 1 2 3 4
VSd [kN] 0.63 0.63 0.63 0.63
Vx,Sd [kN] 0.00 0.00 0.00 0.00
Vy,Sd [kN] 0.63 0.63 0.63 0.63

Proof steel failure without lever arm


h
VSd ≤ VRk,s / g Ms = VRd,s Utilisation:
0.63 ≤ 50.00 / 1.25 = 40.00 1.6%

Proof steel failure with lever arm


No proof required.
Fixture is made of metal and is fixed without intermediate layer
or with a levelling layer of mortar with a thickness e ≤ d/2 (compression strength ≥ 30N/mm²)
e d
0 mm 16 mm

Proof concrete pryout failure


g
VSd ≤ VRk,cp / g Mc = VRd,cp Utilisation:
2.50 ≤ 230.76 / 1.50 = 153.84 1.6%
o o
NRk,c A c,N A c,N Ys,N Yre,N Yec,N k
2 2
39.58 kN 172200mm 57600 mm 0.97 1.00 1.00 2.0

k1 h ef f ck,cube ccr,N e c1,V e c2,V


2
10.1 80 mm 30 N/m m 120.0 mm 0.0 mm 0.0 mm

Proof concrete edge failure (closest edge) Edge cx1


g'
VSd ≤ VRk,c / g Mcq = VRd,c Utilisation:
1.25 ≤ 99.99 / 1.50 = 66.66 1.9%
o o
V Rk,c Ac , V Ac , V Ys , V Yh,V Ya, V Yec,V Yre,V
2 2
25.88 kN 84150 mm 54450 mm 1.00 1.00 2.50 1.00 1.00

k1 d nom lf f ck,cube c1
2
2.4 16 mm 80 mm 30 N/m m 110 mm

Interaction, combined load in most unfavourable case


bN + bV ≤ 1,2 Utilisation:
0.90 + 0.02 = 0.92 ≤ 1,2 76.5%

Designed acc. to ETAG 001, Annex C


Wedge Anchor B A4 M16 hef80 Official approval ETA-01/0013: MKT B
Go ahead, design okay!
Design office: INVENTION STEEL INDUSTRIES
Person in charge: YJT
Construction project: SQM-NIZWA
Number: 0811
Position: Date: 7/22/2014

Page 4 / 4
Product-information
Wedge Anchor B A4 M16 hef80 Official approval ETA-01/0013: MKT B

Installation parameters
Thread M = 16 mm
Diameter of drilled hole d0 = 16 mm
Depth of drilled hole h0(1) = 110 mm
Setting depth hnom = 99 mm
Effective anchorage depth he f = 80 mm
Diameter of clearence hole
in the fixture df ≤ 18 mm
Tightening torque Tinst = 100 Nm
Width across nut SW = 24 mm

Remarks
The anchors are without influence of edge distance, if: c ≥ max ( 10 h e f ; 60 d )
A longitudinal reinforcement shall be provided at the edge of the concrete member.
The design is based on the assumption that the anchor plate remains flat under the acting
forces.
The proof of the capacity of the anchor base component shall be shown according to Annex C of ETAG 001
respectively EOTA Technical Report TR 029, chapter 7.

Vous aimerez peut-être aussi