E1 to RS232/RS485 /RS422

RS232/RS485/RS422
Converter
OP E1 RS232
l

User
User’’s Reference Manual

Version: 2.5
Date: June 16, 2007
-1-

To users:
Thank you for using our products. Before using, please read this
Reference Manual carefully, and keep properly.

Alarm
1. This product can not be caught in or be affected with damp, for they
can make the performance degressive and even broken..
2. Before fixing this product, please check the model and according to the
User’s Reference Manual.

E1-RS232/RS485/RS422 Converter
-2-

Table of contents

1. GENERAL INFORMATION................................................................................................. 4
1.1 APPEARANCE OF PRODUCT............................................................................................4
1.2 FUNCTIONS....................................................................................................................4
1.3 FEATURES......................................................................................................................4
1.4 PARAMETER AND SPECIFICATIONS................................................................................ 5
1.5 DIMENSION....................................................................................................................5
1.6 OPERATION ENVIRONMENT........................................................................................... 5
1.7 PACKAGING...................................................................................................................6
2. INSTALLATION................................................................................................................... 7

2.1 FRONT PANEL................................................................................................................ 7


2.1.1 Indicator LED........................................................................................................ 7
2.1.2 Loop back test button.............................................................................................8
2.2 BACK PANEL................................................................................................................. 9
2.2.1 Power supply......................................................................................................... 9
2.2.2 E1 interface............................................................................................................ 9
2.2.3 RS232 interface....................................................................................................10
2.3 SETTING.......................................................................................................................11
2.3.1 Clock setting........................................................................................................ 11
2.3.2 Mode setting........................................................................................................ 12

3. INSTALLATION PROCEDURE........................................................................................ 13

4. TROUBLE SHOOTING...................................................................................................... 14

5. TYPICAL APPLICATION.................................................................................................. 15

E1-RS232/RS485/RS422 Converter
-3-

E1-RS232/RS485/RS422 Converter
-4-

1. General information

1.1 Appearance of product

Figure 1: product figure

1.2 Functions

E1 to RS232/RS485/RS422 converter provides conversion between ITU-T G.703

standard E1 interface and RS232/RS485/RS422 port and provides safe and seamless

connection of communication between different devices with different interfaces.

Data interface mode is DCE, can connect with DTE or DCE device.

RS232/RS485/RS422 channel can transmit RS232/RS485/RS422 asynchronous

serial signal with auto-adapt baud rate of 0 to 115200.

1.3 Features
� Based on self copyright IC.

� Supports 3 wire RS232(TXD,RXD,GND) and supports flow control CD,


DSR, CTS

� Provides 2 kinds loop back:E1 local loop, RS232/RS485/RS422 local


loop

� Having pseudo random code test function, can used as a 2M Protocol


Analyzer

� Supports both 120Ω/balance and 75Ω/unbalance impedance

� RS232/RS485/RS422 supports hot plug, can connect with DTE or DCE


E1-RS232/RS485/RS422 Converter
-5-

� RS232/RS485/RS422 channel can transmit RS232/RS485/RS422


asynchronous serial signal with auto-adapt baud rate of 0 to 115200

1.4 Parameter and specifications


� E1 interface
Bit rate 2.048 Mb/s 50 ppm
Standard: conform to G.703 standard.
Coding: HDB3
Port transmission: 1Km

Port protection: 1500W surge protection, 15KV ESD protection


Impedance: 75Ω (unbalance), 120Ω (balance)

Connector: BNC (75Ω), RJ45 (120Ω)

Jitter Performance: According to G.742 and G.823


Clock: internal clock, line clock
� RS232/RS485/RS422 interface
Rate: 0 to 115.2Kbps
Interface: compatible with ITU-T V.24 V.11 RS232
Connector: RJ45
Connect mode: DCE
Synchronous serial, lucency transmission
600W surge protection, 15KV ESD protection

1.5 Dimensio
Dimension
Desk top type: 212(W)*138(D)*30(H)

1.6 Operation environment


Voltage: AC180V-265V, DC-48V, DC+24V
Power Consumption: <=5 Watts
Working temperature: -25°C~70°C
Storage temperature: ° °C
-40°C~+85°C
Humidity: 5 ~95%
E1-RS232/RS485/RS422 Converter
-6-

Humidity: 0~95% non-condensing


No causticity and solvent, dust free, and no strong magnetic interference.

1.7 Packaging
Contents in the package

Converter 1

BNC Connector 2

user manual 1

E1-RS232/RS485/RS422 Converter
-7-

2. Installation

2.1 Front panel

Figure 2: front panel

2.1.1 Indicator LED

There are 7 indicator LED on front panel.

From left to right is as following:


Name Color Status Description
TXD yellow wink Indicates RS232/RS485/RS422 data output

RXD yellow wink Indicates RS232/RS485/RS422 data input

ON E1 signal loss
LOS red
OFF E1 signal normal

LOF reserved

ON Under test status(ANA, DIG, REM, PATT pressed any)


TEST yellow
OFF In normal working status
ON PATT pressed, PATT test normal
PTOK green OFF PATT pressed, PATT test not normal
Wink PATT pressed, PATT test has error code
ON Power ON
green
PWR OFF Power not ON

E1-RS232/RS485/RS422 Converter
-8-

2.1.2 Loop back test button

There are 4 switch buttons on the front panel, from left to right as follows:

� ANA:local loop of E1, used to test if local device and connect wire is

normal

Figure3: ANA test button

� DIG:RS232/485/422 local loop back, used to test remote device and

E1 line.

Figure 4: DIG test button

� PATT : pseudo random code test: generate pseudo random code to

RS232/485/422 input port, and test if the output signal of RS232/485

/422 accord with the standard. PTOK ON if accord, OFF if not accord.
E1 port

RS port

PATT E1
Circuit
RX compare

Loop 1 Loop 2

There must be one loop back when test

Figure5: PATT test button

detect if local device work normal when loop 1 open, detect if E1 transmission

line and both device work normal when loop 2 open and loop 1 close.
E1-RS232/RS485/RS422 Converter
-9-

� REM: reserved.

Note:
1) press any button of front panel will stop normal data transfer,

and shift to test mode.

2) The connection should be a loop when in PATT mode, or no

return for the send pseudo random code.

2.2 Back panel

Figure 6: Back panel

2.2.1 Power supply

� AC220V power supply socket connect to the power wire directly.

� DC-48V power supply socket: -48V;If the power of DC -48V is used,

the positive and negative terminal can be optional because there is the

self-test circuit for the polarity inside it.

2.2.2 E1 interface

E1 interface of this device provides 75Ω and 120Ω impedance adapt, no need

set.

Unbalance E1 (75Ω), and balance E1 (120Ω) switch button is on the back

panel.
E1-RS232/RS485/RS422 Converter
- 10 -

� 75Ω: BNC,RX: input,TX: output;

� 120Ω: RJ45

The definition of pins as follows:

Figure 7: E1 interface pin definition

2.2.3 RS232 interface

For RS232:

There isRJ45 interface on back panel, which is DCE standard interface for RS232.

For RS485/422:

There isRJ45 interface on back panel, the definition is as follows:

E1-RS232/RS485/RS422 Converter
- 11 -

2.3 Setting
8 DIP switches on the back panel used for E1 clock setting.

2.3.1 Clock setting

8 DIP pull switch on the front panel, DIP 1-2 is clock switch.
DIP1 DIP 2 description
OFF(up) OFF(up) E1 internal clock(default), master mode
ON(down) ON(down) E1 line clock, slave mode

� Internal clock: use clock generated by internal crystal, receive clock is

generated from E1.

� Line clock: working clock from received E1 signal.

E1 clock mode choice:

� When working in pair, both internal clock, or one internal and the other line

clock.

� Try to make only one device provide clock in connection.

� Avoid all devices in connection use line clock. If be sure that device provides

clock, then to set other as line clock. If not sure, set the device as internal clock.

E1-RS232/RS485/RS422 Converter
- 12 -

2.3.2 Mode setting

DIP3-4 for RS232 mode setting:


DIP3 DIP 4 Description
OFF(up) OFF(up) RS422 mode
ON(down) OFF(down) RS232 mode
OFF(up) ON(down) RS232 mode
ON(down) ON(down) RS485 mode

E1-RS232/RS485/RS422 Converter
- 13 -

3. Installation Procedure

� Unpack, inspect the content carefully. Verify that all items are included with
your carton. Contact us or local agent if there is any content missing or
damaged.
� Check power supply configuration. Care about the value of voltage if use DC
input.
� Take following tests before usage:
� Check if all the loop back test switch buttons on back panel is loosen,
PWR and LOS should be ON, and all other LED should be OFF.
� Press PATT button, TEST should be ON, PTOK should be OFF. Then
Press ANA button, PTOK ON and LOS OFF.
� If used in pair, when press PATT button, you may not press ANA, then
press DIG or REM of remote device, PTOK should be ON.
� If indicator LED works normal, unpress all switch on the back panel and
power off, set clock, plug E1 wires, then power on, the device should work
normally.
� If device does not work normally, please refer to chapter 4: trouble shooting.
Contact us or our local agent in time if the problem can’t be solved.

E1-RS232/RS485/RS422 Converter
- 14 -

4. Trouble shooting
When work normal, LINK, PWR, DATA LED ON, all other LED OFF.

phenomenon solution
1 PWR OFF Check if power supply connect ok
Loop back TX(output
output)and RX(input
output input
input),if LED OFF,
2 LOS ON
check the E1 wire
Check if test button pressed, TEST is ON, and reset
all button
all LED Serial data start bit error, restart software or device
work
3 normal, but Press PATT, and remote loop back (press DIG), if
no data PTOK OFF, then E1 channel have problem.
transmission Check if having data loop back to RS232/485/422
RS232/485/422
(such as SDH E1 loop, remote DIG pressed),press
local PATT, if PTOK ON, then having loop.

Check if both devices have been set as line clock, the


Data
correct setting should be:
transmission
4 1)both devices internal clock
but having
2)or one device internal clock and the other line
loss
clock

Note
Note:howhow to check the device work normal?
(1) if press ANA on one device, and press PATT,PTOK ON, if unpress ANA,
PTOK OFF, then the device work normal.
(2) if press PATT, PTOK OFF, press DIG on remote device, PTOK ON, then
both devices and E1 works normal.
caution
caution:
1、TEST
TEST ON some button ON , maybe stop normal data communication
ON(some communication)
2、 pseudo random code PATT
code(PATT
PATT)testtest must having loop, or the send pseudo
test,must
random code would not return.

E1-RS232/RS485/RS422 Converter
- 15 -

5. Typical application

Figure 8: typical application