Shutdown SIS

Previous Screen

Product: EXCAVATOR
Model: 320D EXCAVATOR FAL
Configuration: 320D & 320D L Excavators FAL00001-UP (MACHINE)
POWERED BY C6.4 Engine

Testing and Adjusting


320D, 321D, 323D, 324D, 325D, 328D and 330D Excavators Tool Control System
Media Number -RENR7389-09 Publication Date -01/07/2007 Date Updated -19/07/2007

i02588581

Service Mode - Enter


SMCS - 5000

This procedure is used to enter the service mode of the operator monitor.
Illustration 1 g01198159

1. Illustration 1 is the default screen of the monitor. This screen appears when the monitor is initially turned
ON.
Illustration 2 g01197980
(1) Up key

(2) Right key

(3) Home key

(4) Main menu

(5) Left key

(6) Down key

(7) Cancel key

(8) OK key
Illustration 3 g01197981

2. Press menu key (6) . Illustration 3 will be displayed. Press right key (2) in order to highlight "SERVICE"
menu option.

3. After the "SERVICE" option is highlighted, press OK key (8) .


Illustration 4 g01220271

4. After OK key (8) is pressed, the above screen will be displayed. The keys for direction are used to input the
password. Different passwords allow access to menus that are in the monitor. For more information on the
passwords, Refer to Systems Operation, "Monitor Overview" for the Tool Control System. The password that
allows access to all menus that are used for service is "FFF2". Press left key (3) or right key (4) in order to
change the position of the flashing character. Press the OK key (8) in order to enter the highlighted character.
Illustration 5 g01220277

5. After entering the last letter of the password, the monitor will continue with the "SERVICE" screen.
Illustration 6 g01220279

6. When the correct password is entered, the "SERVICE" menu will appear.
Illustration 7 g01220281

7. If an incorrect password is entered, Illustration 7 is displayed.

8. Press the OK key (8) in order to retry the password. Press the cancel key (7) in order to exit the program.

Exiting the Service Mode


Three methods are used in order to terminate the service mode. The service mode will be terminated 10 seconds
after the start switch is turned to the OFF position. Use the procedures below if the start switch is not turned to the
Off position.

1. Press the cancel key (7) . The monitor will display the previous menu when the cancel key is pressed. Stop
when the default screen appears.

2. Press the home key (4) . By pressing the home key, the monitor will automatically go to the default screen.
Copyright 1993 - 2009 Caterpillar Inc. Fri Jan 30 15:17:55 UTC+0630 2009
All Rights Reserved.
Private Network For SIS Licensees.