RESULT AND DATA ANALYSIS

Test 2
Pump Speed, N: 2296 rpm Percentage of speed: 75%

𝜔: 240.437 rad/s

No INPUT OUTPUT Efficiency


Water Torque, Shaft Power Volume Flow Rate Inlet Pressure, P1 Discharge Water Output ,Ƞ
Height T (Nm) Pressure, P2 Head, h Power,
(100%)
(mm) kW Hp l/min m3/s mH2O N/m2 psi N/m2 (m) Watt
(100%) (100%)
1 0 1.1 0.264 0.353 0.0 0.0 0.2 0.196×104 21 1.448×105 14.561 0.0 0.0
2 69 2.1 0.505 0.673 106.0 1.767×10-3 -0.1 -0.098×104 19 1.310×105 13.454 233.215 46.18
3 75 2.4 0.577 0.769 132.0 2.200×10-3 -0.3 -0.294×104 17 1.172×105 12.247 264.315 45.81
4 81 2.6 0.625 0.834 157.0 2.617×10-3 -0.7 -0.686×104 15 1.034×105 11.240 288.562 46.17
5 85 2.7 0.649 0.866 177.0 2.950×10-3 -1.0 -0.981×104 13 0.896×105 10.134 293.273 45.19
6 89 2.8 0.673 0.898 200.0 3.333×10-3 -1.2 -1.177×104 11 0.758×105 8.927 291.884 43.37
7 92 2.9 0.697 0.930 215.0 3.583×10-3 -1.4 -1.373×104 9 0.621×105 7.730 271.704 38.98
8 93 3.0 0.721 0.962 222.0 3.700×10-3 -1.6 -1.569×104 7 0.483×105 6.523 236.765 32.84
9 95 3.0 0.721 0.962 235.0 3.917×10-3 -1.8 -1.765×104 5 0.345×105 5.316 204.271 28.33
Test 3
Pump Speed, N: 3128 rpm Percentage of speed: 100%

𝜔: 327.563 rad/s

No INPUT OUTPUT Efficiency


Water Torque, Shaft Power Volume Flow Rate Inlet Pressure, P1 Discharge Water Output ,Ƞ
Height T (Nm) Pressure, P2 Head, h Power,
(100%)
(mm) kW Hp l/min m3/s mH2O N/m2 psi N/m2 (m) Watt
(100%) (100%)
1 0 1.8 0.590 0.791 0.0 0.0 0.2 0.196×104 38 2.620×105 26.508 0.0 0.0
2 79 3.7 1.212 1.625 147.0 2.450×10-3 -0.4 -0.392×104 35 2.413×105 24.997 600.790 49.57
3 85 4.1 1.343 1.801 177.0 2.950×10-3 -1.0 -0.981×104 32 2.206×105 23.487 679.700 50.61
4 90 4.4 1.441 1.932 205.0 3.417×10-3 -1.4 -1.373×104 29 1.999×105 21.777 729.982 50.66
5 95 4.6 1.507 2.021 235.0 3.917×10-3 -1.8 -1.765×104 26 1.793×105 20.076 771.436 51.19
6 99 4.8 1.572 2.108 260.0 4.333×10-3 -2.1 -2.059×104 23 1.586×105 18.266 776.428 49.39
7 101 4.9 1.605 2.152 273.0 4.550×10-3 -2.8 -2.746×104 20 1.379×105 16.856 752.376 46.88
8 103 5.0 1.638 2.197 287.0 4.783×10-3 -2.9 -2.844×104 17 1.172×105 14.846 696.593 42.53
9 105 5.2 1.703 2.284 300.0 5.000×10-3 -3.1 -3.040×104 14 0.965×105 12.936 634.511 37.26
10 108 5.3 1.736 2.328 323.0 5.383×10-3 -3.6 -3.530×104 11 0.758×105 11.325 598.042 34.45
11 110 5.3 1.736 2.328 337.0 5.617×10-3 -4.0 -3.923×104 8 0.552×105 9.626 530.419 30.55
16 50

14 45
BHP (kW), Water Head (m)

40
12
35

Efficiency (%)
10 30
8 25

6 20
15
4
10
2 5
0 0

Volume Flow Rate (m3/s)

BHP (kW) Water Head (m) Efficiency (%)

Graph 2: BHP, Head, Efficiency versus Volume Flow Rate (75%)

30 60
BHP (kW), Water Head (m)

25 50

20 40
Efficiency (%)

15 30

10 20

5 10

0 0

Volume Flow Rate (m3/s)

BHP (kW) Water Head (m) Efficiency (%)

Graph 1: BHP, Head, Efficiency versus Volume Flow Rate (100%)


SAMPLE CALCULATION

(Taking the data No. 3 of TEST 2 as an example, N = 2296 rpm)

Calculation for INPUT POWER


 To find the shaft power
Convert pump speed, N (rpm) into angular speed, 𝜔 (rad/s):
* 1𝑟𝑒𝑣 = 2𝜋 𝑟𝑎𝑑, 1𝑚𝑖𝑛 = 60𝑠𝑒𝑐
𝑟𝑒𝑣 1𝑚𝑖𝑛 2𝜋 𝑟𝑎𝑑
𝜔 = 2296 × ×
𝑚𝑖𝑛 60𝑠𝑒𝑐 1𝑟𝑒𝑣
= 240.437 rad/s

Apply shaft power, W, formula:


* 𝑊 = 𝑇𝜔
W = 2.4(240.437)
= 0.577 kW

Convert unit of shaft power from kW to hp:


* 1 kW = 1.341 hp
W = 0.577 x 1.341
= 0.769 hp
Calculation for OUTPUT POWER
 To find the volume flow rate (Q) using graph 90˚ VEE NOTCH CALIBRATION where
water height against volume flow rate
Change L/min into 𝑚3/𝑠:
* 1 L/min = 1.667 × 10-5𝑚3/𝑠
Q = 132 x 1.667 × 10-5𝑚3/𝑠
= 2.200 x 10-3 m3/s

 To find inlet pressure, P1 and Discharge pressure, P2


Convert unit of inlet pressure, 𝑃1 from m𝐻2O into N/𝑚2:
* 1 m𝐻2O = 9806.65 N/𝑚2
-0.3 m𝐻2O, -0.3 × 9806.65 N/𝑚2 = -0.294×104 N/𝑚2
Convert unit of discharge pressure, 𝑃2 from psi to N/𝑚2:
* 1 psi = 6894.757 N/𝑚2
17 psi, 17 × 6894.757 N/𝑚2 = 1.172×105 N/𝑚2

 To find the water head, ℎ𝑝 (m)


ℎ𝑝 = (𝑃2-𝑃1) / 𝜌𝑔
= [1.172×105 N/𝑚2 – (-0.294×104 N/𝑚2) / (1000 𝑘𝑔/𝑚3 x 9.81𝑚/𝑠2)
= 12.247 m

 To find output power, Watt


𝑃𝑓 = 𝜌𝑔𝑄ℎ𝑝
= (1000 𝑘𝑔/𝑚3) (9.81𝑚/𝑠2) (2.200 X 10-3 𝑚3/𝑠) (12.247 𝑚)
= 264.315 W

Calculation for EFFICIENCY, η


η = (𝑃𝑓/ 𝑊̇𝑠ℎ𝑎𝑓𝑡) x 100%
= (264.315 W/ 0.577 𝑘𝑊) x 100%
= 45.81%