V200R015
Northbound export all
parameters operation guide
Issue 01
Date 2015-05-05
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 Description ..................................................................................................................................... 1
2 Operation guide............................................................................................................................. 2
1 Description
In CME V200R015, Northbound supports export all parameters, but in the default version,
Northbound only supports to export commonly used parameters. Customer needs to operate
the following commands if they hope to export all parameters.
Note:
After operate the following commands, all the specified NE versions which installed in CME
Server will export all parameters.
The CmeServer will be restarted.
If customer installed a new CME component package, they need operate the following
commands again.
2 Operation guide
Step 1: Run the following command to set U2000 environment variables (note that a space exists between the
dot and the slash):
. /opt/oss/server/svc_profile.sh
NBIModel/BaseStation/NodeB/V100R009C00/MocExpInfo.xml
NBIModel/BaseStation/LTE/V100R009C00/MocExpInfo.xml
NBIModel/BaseStation/MRAT/V100R009C00/MocExpInfo.xml
…
Example:
(1) setFullParamMode.sh all
(2) setFullParamMode.sh MBSCModel/MocRelation/UO/V900R016C00/MocExpInfo.xml
NE Version File
NE Version File
NE Version File
NE Version File
2. Set specified component all parameters, run the following command(The component’s file name can get
by run “setFullParamMode.sh”. The “All components in current environment:” lists all components’ file
name.):
setFullParamMode.sh MBSCModel/MocRelation/UO/V900R016C00/MocExpInfo.xml