Vous êtes sur la page 1sur 30

Technical Proposal

PT. PROMOSINDO MIDIA TENAGA

Technical Proposal Page 1


Contents

INTRODUCTION 3
OUR STANDARD EQUIPMENT 5
1. LOGGING CABIN 5
2. COMPUTER SYSTEM AND SOFTWARE FEATURES 7
3. DEPTH MONITORING SYSTEM 18
4. PUMP STROKE COUNTING SYSTEM 18
5. PIT LEVEL SENSORS 19
6. HOOK LOAD SENSORS 21
7. ROTARY TABLE or TOP DRIVE RPM SENSOR 22
8. TORQUE SENSOR 23
9. PRESSURE SYSTEM SENSOR 23
10. RETURN FLOW SENSOR 24
11. MUD TEMPERATURE IN / OUT SENSOR SYSTEM 25
12. MUD DENSITY IN / OUT SENSOR SYSTEM 25
13 GAS DETECTION SYSTEM 26
GAS TRAP 26
GAS CHROMATOGRAPH 27
TOTAL GAS 27
GAS NON – HYDROCARBON ANALYZER 28
14. GEOLOGICAL ANALYSIS EQUIPMENT 28
BINOCULAR ZOOM MICROSCOPE 28
FLUOROSCOPE, ULTRAVIOLET VIEWING BOX 29
DRYING OVEN 29
CALCIMETRY 29
SHALE DENSITY EQUIPMENT 30
CUTTING PREPARATION & DESCRIPTION TOOLS 30
15. MISCELLANEOUS SUPPORTING EQUIPMENT & CONSUMABLES 30

Technical Proposal Page 2


INTRODUCTION
PT. PROMOSINDO MIDIA TENAGA as national company which since 1987 has been providing services for the
leading national Oil Companies particularly in the Mud Logging services.
During its thirty years services the company has worked for about 80 development wells, and 220 exploratory
wells. Through Indonesia and has completed on the jobs zero accident.
PT. Promosindo Midia Tenaga has carry out must be efforts to improve our services thrugh the development of
technology applied to our equipments, professional knowledge and skill for the engineer’s and technician,
beside the company has and forced the culture of safety-health and environment.

SCOPE OF OUR SERVICES :

1.Detection and Determination of Hydrocarbon shows in Drilling Fluids


Continuously monitor, record and report the amount of gas in the drilling fluid using a Total Gas Detector.
Continuously gas chromatographic analysis of hydrocarbon gases C1 – C5.
Continuously monitor and check all background gas, trip gas and connection gas, etc.

2.Surface Drilling Parameter Monitoring


Continuously monitor, record and presenting graphic with the following datas:
Control Depth
ROP measurement
Hook position
Hook load and weight on bit.
RPM and Torque
Standpipe pressure
Pump strokes.
Pit Volumes

3.Monitoring of Drilling Fluids Mud System


Continuously monitor the following:
Returns of mud flow rate from the well (using paddle type )
Volume transferred between pits
Mud pits and trip tank volume (5 pits and 1 trip tanks)
Active pits and pit volume totalizer
Mud Density In and Out.
Mud Temperature In and Out.
Mud flow rate measurement ( GPM calculated from SPM )

Technical Proposal Page 3


4.Sampling and Sample Analysis
Collect and prepare ditch cutting samples at specified intervals.
Check and calculate lag time.
Carry out detailed lithological description of ditch cutting samples.
Check for hydrocarbon indication in ditch cutting samples.
Collect, packed, labeled and dispatch of ditch cutting samples.

5.Data Engineering (Basic Pore Pressure Detection) Services


PT. PROMOSINDO MIDIA TENAGA offers a tiered approach to pore pressure services to cover a broad
spectrum of customer requirements. At the introductory level, mud logging crews can offer a basic level of
reporting including, but not limited to parameters such as ROP, DXC, Weight on Hook, Gas Analysis, Cavings,
Cuttings Character and Flowline Temperature for any project.
Hydraulics Calculations
Torque plot
D-exponent plot/log
Fracture gradient plot/log
Overburden gradient plot/log
Pore Pressure Gradient plot/log
Kill sheet calculations
Produced gas data (i.e. connection, trip, swab gas, pump-off gases)
Gas Ratio plot/log
LOT data

6.Give Advise to Wellsite Geologist and Company Man Rep


Report and give to advise to the Wellsite Geologist and Company Man related to finding finding and
anomolys for further consideration and determination or decision.

7.Personnel
PT.Promosindo Midia Tenaga has offer fully employed personnel included D.A.T.A Engineers ( Pressure
Engineers and Mud Loggers ) and Service Engineers ( Techicians ) are fully comptence and experiences. Our
Presure Engineer are having more than 10 years experience while Mud Logger at list have 5 years of
experience. There are all our dedicated personnel.

Technical Proposal Page 4


OUR STANDARD EQUIPMENT

1. THE MUD LOGGING UNIT / CABIN

CABIN UNIT
A rugged, all steel, skid mounted logging unit with
double door access, designed to accommodate all
equipment required to perform services.
Interior includes all cabinets, benches, permanent
fixtures, and sufficient space for storage of required
spare parts and supplies.
Suitable for Class 1, Division II, Areas.
American Bureau of Shipping (ABS) Certified.

STANDARD UNIT SPECIFICATIONS:


.
 The Logging Unit is sertified DNV 27.2 for electrical instrument Cabin system suitable for hazardouse
area
 3 KVA, Un-interruptible Power Supply capable of providing backup power at full load (all
units computers and monitors) . Permits continuous operation of data logging in the
event of rig power interruption or failure for 90 minutes.
 Certified Lifting Slings provided with unit for load-out.
 2 sets Interior Emergency lights providing lighting in equipment and company Geologist areas.
 Double door for main door to provide air lock
 One escape hatch at rear side
 Unit Dimensions: 27 ft. . Long
8 ft. . High
9 ft. Wide
 Power Requirements: 380-480 VAC, 3-phase
60-ampere main breaker
50/60 Hertz.
25 KVA transformer
 Minimum two (2) UPS to supply power for at least 120 minutes with minimum
 requirement load. Minimum Two (2) power stabilizers to output regulated power.
 Stainless steel sink can be connected to potable water or drill water. Drainage hose is connected at
unit external.

Technical Proposal Page 5


 Weight: 9.5-10 metric tons (20,950-22,050 lbs.)
Fully-loaded with equipment and spares
 All the sensors and motors offered for mudlogging are explosion proof and free from all sorts of
induction and interference, which are suitable for both mechanical and electrical rigs.

ADDITIONAL FEATURES:

 Provides separate area for Company Geologist and/or Engineer to perform their duties.
 Independent hookups for access to Laser printer, Coloured Desk jet printers and network provided in
company Geologist work area.
 Independent monitor hookup provided in company geologist work area.
 Certified DNV 27.1 for Lifting Structure
 Safety Equipment, including Two (2) Fire Extinguisher.

Technical Proposal Page 6


2. COMPUTER SYSTEM AND SOFTWARE FEATURE

PT PMT provided from the very basic to the geological surveillance solution through are
 32 bit state of the art system

 Real time data acquisition , monitoring, processing and interpretation tool

 Feature of providing information in real time to decision makers involved in mission critical and time
critical decisions

 Web base System & WITS System

Each unit features :


 Continues DATA Acquisition

 DATA Server with back-up data facilities

 Real time DATA Monitoring with alarm function using :

 4(Five) LCD Drilling Monitor installed at Mud Logging Unit and COMPANY’s Drilling
Representative Office

 1(One) pressurized LCD Drilling Monitor installed at rig floor

 1(One) LCD Drilling Monitor installed at Company Man Room

 1(One) continues log printers/charts at Mud Logging unit and 1(one) printer offline for print
out Daily Geological Report and Morning Report

Technical Proposal Page 7


 1(One) offline Notebook system (Pentium i3 processor, 500 GB Hard Disk,4 GB RAM ,DVD Combo,
VGA and Sound Card, 3 USD Port) including color printer to produce Master Mud Log, Gas Ratio
Log and Pressure Log on the offline PC format. Drilling Engineering, application software (d-
exponent, formation over pressure, over burden and fracture gradient, leak of test, hydraulic,
kick control, deviation well) to support Pressure Engineers in performing Formation Pressure
Detection Services.

2.1 Software Feature of Server Online

Our software has a user friendly interface, easy to use and also reliable and run in windows platform and
100% Graphical User Interface (GUI).

Picture 2.1. Server User Interface

2.2 Software Feature of Real time Graphic Monitoring

For alternatively, we performed all drilling data parameter with graphical user interface. User can more easily
to take a conclusion with some parameter and can make a right decision more faster. Our graphic
representation built in with time base and depth base function, it can be used alternatively or both.

Technical Proposal Page 8


Picture 2.2. Realtime Graphic Monitoring User Interface

2.3 Software Feature of Rig Floor Monitoring

We provide panel monitoring in Rig Floor. It’s represent mainly parameter used for drilling job (Depth, Pump
Rate, ROP, etc). It’s also can be customized if there any request from driller to perform different configuration.

Picture 2.3. Rig Floor Monitoring User Interface

Technical Proposal Page 9


2.4 Software Feature of Database Editor

Database is commonly used for request past data. Our database can save more than 3 month drilling data
parameter and will not miss any important drilling data parameters.

Picture 2.4. Database Editor

2.5 Software Feature of Web Base and Mobile Monitoring System

Web Base system can monitor our field data in remote location with web browser like Mozilla, Internet
Explorer, Google Chrome, etc. which have internet connection . Our web base system can be easily configured
and used because it does not require any software installation and it’s based on new html 5 technologies. Our
web base system use secure authentication for every user who accessed the real time well data. Encryption for
data also can be configured if user need more secure configuration. We also use secure connection with SSL
for transmitting data from location to our server in Jakarta

For user simplicity, our drilling data parameters can also be monitored in real time and offline mode widely
with any mobile platform (blackberry, PDA, mobile phone, tablet, etc.). We have “smart” web base system for
mobile with adaptive bandwidth technology. This system can reduce bandwidth usage significantly, and very
suitable for mobile device application.

We also have database synchronization system between remote location and Jakarta office server, so it’s
guaranty that we would not miss any data from remote location. This system also has a mirroring scheme for
the database, so when something happen in location (blow out), we already have backup up the data
automatically.

In our web base system, all previous data can be loaded for analysis purpose(historical mode). The
Query(selecting criteria) can be selected by time, depth, and both. The database can save the well data until 6
month, even more because it’s depending on server hard disk capacity.

Technical Proposal Page 10


Picture 2.5. Web Base Monitoring Representation with location based

Picture 2.5.1 Web Base Monitoring Representation with drilling parameter(time based)

Technical Proposal Page 11


Picture 2.5.2 Web Base Monitoring Representation in Trip Mode(time based)

Picture 2.5.3 Web Base Monitoring Featuring Oil Ratio(depth based)

Technical Proposal Page 12


Picture 2.5.4 Web Base Monitoring Drilling Well Plan

Picture 2.5.5 Web Base Download Station for Raw Data in various Format(csv,excel)

Technical Proposal Page 13


Picture 2.5.6 Web Base accessed from Tablet with adroid 2.2(froyo) os.

2.6 Networking Diagram

Our company has wide computer networking system, so our data can be monitored in every where around the
world with help of internet connection. Mobile phone, PDA and Blackberry can receive our data in field
clearly.



2.7 Master Log

Technical Proposal Page 14


2.7 Mater Log

We have used Geodraft for make a MudLog, Pressure Log and Gas Ratio Log because it’s easy to use operate
and fully customizable and Master Log can be shown in units of MD or TVD

Picture 2.7 Mud Log MD and TVD

Picture 2.7 Mud Log MD and TVD

Technical Proposal Page 15


2.8 Sofware Feature of Realtime Hydrolic Calculation

We also have hydraulic calculation.

Picture 2.8 Realtime Hydrolic Calculation

2.9 Sofware Feature of Pore Realtime Pore Pressure Calculation

We can calculate Real time Pore Pressure, so it’s can be used for early warning if abnormal pressure is showed
up.

Picture 2.9 Realtime Pore Pressure Calculation

Technical Proposal Page 16


2.10Software Feature of Realtime Gas Oil Ratio Calculation

We have Real time Gas Oil Ratio Calculation, so user can compare the water and oil more faster.

Picture 2.10 Realtime Gas Oil ratio Calculation

2.11PMT Smart System Analysis for Early Warning System

PMT with smart system analysis can predict real time condition on remote location, so if strange anomaly
detected while drilling, the system will have notification earlier. Our system work based on Neural network
principle.

Picture 2.11 PMT Smart System Analysis for Early Warning System

Technical Proposal Page 17


4. DEPTH MONITORING SENSOR

The bit tracking sensor is used to measure drill depth, bit location, rate of penetration,
drill pipe velocity, and peak drill pipe velocity. The sensor is installed on the draw work
of the drilling rig in close proximity to the fast sheave. It is wired through a safe barrier
for intrinsic safety. The sensor is designed and custom built by PMT.

SPECIFICATIONS:

GENERAL DESCRIPTION : Depth Sensor


INTERVAL OF MEASUREMENT: Variable down to 3in
or10cm
ACCURACY :
1) Target count: ± 1
2) Depth system accurate to 1% or better
3) Drilling time measuring 0.01 min/m to 600mtr /min
185m/min)
OPERATING ENVIRONMENT:
-15°F to 160°F (-26°C to +71°C) 99% Humidity
PRINCIPLE OF OPERATION :
Target counts by proximity sensor
SIGNAL OUTPUT : Logic low and high, 0v and 5vdc
MEASUREMENT OF PURPOSE: Depth and ROP, Bit Location, Pipe Velocity, and Peak Velocity

5. PUMP STROKE SENSORS

DESCRIPTION:

A Proximity Switch used to determine pump speed by detecting rig pump


piston movement or machine rotations, whenever the gear is exposed,
depending on pump design. From counter-timer hardware with software
calculations, parameters such as Instantaneous RPM, Total RPM,
Rotating Time, are obtained.

SPECIFICATIONS:

BRAND: Turck
MODEL: Ni20-CP40-Y1X

Technical Proposal Page 18


SENSOR TYPE: Discrete Inductive NAMUR-type Proximity Sensor
OPERATING DISTANCE: 20 mm (10 mm recommended)
ACCURACY: 1 SPM
VIBRATION: 55 Hz, 1mm Amplitute (in all 3 planes)
SHOCK: 30 g, 11 ms
OPERATING TEMPERATURE: -25ºC to +70ºC (-13ºF to 158ºF)
APPROVALS/CERTIFICATION: Physikalisch-Technische Bundesanstalt (PTB):
EEx ia IIC, EEx ib, IIC

Option Other:
BRAND: Varikont
MODEL: NCB 15 +U1+NO
SENSOR TYPE: Normally Close ( NC ) NAMUR-type Proximity Sensor
OPERATING DISTANCE: 13.5 – 16.5 mm typ
ACCURACY: 1 SPM
OPERATING TEMPERATURE: -25ºC to +100ºC (-13ºF to 212ºF)
APPROVALS/CERTIFICATION: Physikalisch-Technische Bundesanstalt (PTB):
IG, 2G, 1 D

6. PITS LEVEL SENSORS

DESCRIPTION:

Enclosed pit room areas of the latest rig designs, although they
are an improvement on keeping away from pit area workers the
hazardous fumes from drilling mud and additives, have
inadvertently trapped steam within the tanks, making the
temperature gradient too unstable for the legacy ultrasonic
sensors to function reliably over the long term.
Radar sensors provide the answer to handle effective and reliable
pit monitoring system onboard such rigs. Operating at 6.3 GHz,
the radar signals are unaffected by any temperature gradient
caused by steam or other fumes.

SPECIFICATIONS:

GENERIC DESCRIPTION: Radar Pit Sensor


BRAND (Sensor): Siemens
MODEL (Sensor): Sitrans Probe LR

Technical Proposal Page 19


BRAND (Barrier): Pepperl + Fuchs
MODEL (Barrier): KFD2-STC4-EX2
SENSOR TYPE: Radar (6.3 GHz models)
INSTALLATION LOCATION: Active Pit, Reserve Pit, Slug Pit,
Mixing Tank
MEASURING RANGE: 1 to 65 ft (0.3 to 20 m) [reversible SPAN]
OPERATING TEMPERATURE: -40 to 176ºF (-40 to 80ºC)
ACCURACY: 0.1% of range or 0.4” (10 mm), whichever is greater
RESOLUTION: +- 0.04 inch (+- 1 mm)
APPROVALS/CERTIFICATION: CSA, FM: Class I, Div. 1, Groups A, B, C, D; Class II, Div 2,
Groups E, F, G; Class III T4
ATEX: ATEX II 1G, EEx ia IIC T4
IEC: IECEx TSA 04.0020X Ex ia IIC

OPTION OTHER :
PIT LEVEL AND TRIP TANK SENSOR
Potentiometer system, utilizing floats and magnetic reed switches. Monitors 7 pit; any combination of pits can
be monitored; active, inactive trip tanks.

SPESIFICATION:

RANGE :
0 to 8ft (2.4m),
ACCURACY :
0.5in (1.27cm),
REPEATABILLITY:
0.3%
OPERATING ENVIRONMENT :
-40°F to +260°F (-40 °C to +126 °C)
MOUNTING :
Clamp on tank
PRINCIPLE OF OPERATION :
Potentiometer, Float and Magnetic Reed Switch
SIGNAL OUTPUT :
0 - 5vdc
MEASUREMENT OF PURPOSE :
Drilling Fluid Volume in Pits and Trip Tank

Technical Proposal Page 20


7. HOOK LOAD SENSORS

A hookload sensor is critical to measure the weight of the block and the drill string while hanging to the block.
It is used to provide the following:
1. On bottom, off bottom and on slip switch (to activate depth monitoring)
2. To measure overpull and drag.
3. To measure pick-up and slack-off weight.

OPTION 1: TRANSDUCER TYPE

A pressure transducer is mounted into the Drilling Rig hydraulic system to measure Pressure at the Deadline
Anchor. From calculations within the PMT software; Hook-load, Weight on Bit, Drill-string Weight etc, may be
calculated.

STANDARD UNIT SPECIFICATIONS:

BRAND: GP 50
MODEL: Mode 312 Pressure Transmitter
SENSOR TYPE: Isolating Diaphragm - Polysilicon Sensor
INSTALLATION LOCATION: Deadline Anchor (Hookload), Torque Manifold
MEASURING RANGE: 0-1000 psi
ACCURACY: +- 0.2% of SPAN
APPROVALS/CERTIFICATION: Explosion proof for Class I, Division I, Groups B, C, and D. Dust-Ignition
Proof for Class II and Class III, Division 1, Groups E, F, and G.

OPTION 2: TENSION TYPE

DESCRIPTION:
The line-tension transducer is mounted near the deadline anchor of the rig wire rope system.
Hookload is measured by monitoring the amount of tension created by the load of the Top Drive , System or
swivel and Kelly.
The sensor is independent of all drilling contractor systems and hence does not affect
nor depend on the functionality of the hydraulic system of the rig

Standard Unit Specifications.

BRAND: Varco
MODEL: TCE-100K Line-Tension Transducer.
SENSOR TYPE: Strain-gage (Wheatstone Bridge).
INSTALLATION LOCATION: Deadline Anchor.

Technical Proposal Page 21


MEASURING RANGE:
100.000 lbs (45,360 kg), single-line load. For 10 lines, effective range is 1,000,000 lbs (453,600 kg).
ACCURACY: +- 0.2% of SPAN.
OTHER FEATURES:
Accepts wire-rope diameters from 7/8 to 2 inches (22.5 to 50.8 mm) without requiring modification.
Lightweight – 17 pounds (7.7 kg).
APPROVALS/CERTIFICATION:
EEx ia IIB T6 to EN50 020 (ISSeP certificate number 94.101.199X), Class I, Division 1, Groups C & D
hazardous locations, temperature code T4 (UL file E139543). “CE” marked for compliance with European
Union EMC Directive (89/336/EEC).

8. ROTARY or TOP DRIVE PIPE RPM SENSOR

This sensor is used to detect the actual rotation per minute (RPM) of the drill string. A Proximity Switch is used
to detect a metal target (minimum 1-mm thick) on the Kelly or Top Drive System. Measures RPM. From
countertimer hardware with software calculations, parameters such as Instantaneous RPM, Total RPM,
Rotating Time, are obtained.

SPECIFICATIONS:
MAXIMUM COUNT RATE : 1200 counts per minute
STABILITY : Stable throughout operating range.
OPERATING ENVIRONMENT :
-15°F to +160°F (-26°C to +71°C) 95% Humidity
MOUNTING :
a target Clamp to Rotary Table.
PRINCIPLE OF OPERATION :
Strokes measured by switch closures
SIGNAL OUTPUT :
Logic low and high, 0 and 5vdc

9. TORQUE SENSOR

Torque sensor is used to measure the force required to to rotate the drill string. Rotary torque sensor is
installed within the Top Drive control panel area. It is clamped to the power supply cable of the Top Drive
System and it measures the “Hall Effect’ of the current that flows through the power cable.

Technical Proposal Page 22


SPECIFICATIONS :

BRAND (Sensor): Ohio Semitronics


MODEL: CT-3477SA
BRAND (Barrier): Pepperl + Fuchs KFD2-STC4-Ex1
SENSOR TYPE: Split Core Current Transducer
INSTALLATION LOCATION: Top Drive System Control Panel Area
MEASURING RANGE: 0-1000 amps DC
OVER RANGE: 10,000 amps (without damage)
ACCURACY & LINEARITY: ±20 amps DC
RESPONSE TIME: ±1 msec
REPEATABILITY: ±10 amps DC (at 25ºC)
OPERATING TEMPERATURE: -10ºC to +60ºC (14ºF to 140ºF)
DC INSERTION LOSS: None
CORE INDUCTANCE: Negligable
FREQUENCY RESPONSE: dc to 1KHz
ISOLATION: 5 KVdc
APPROVALS/CERTIFICATION: BAS: Intrinsically Safe EEx ia IIA T4

10. PRESSURE SYSTEM SENSORS

A pressure transducer can be mounted into the following manifold:


1. Rig’s Standpipe Manifold or Hydraulic system to measure the Standpipe Pressure or the Pump Pressure.
2. Rig’s Choke Manifold to measure the Choke or Casing Pressure.
3. Cementing Unit’s manifold to measure the pressure exerted from the cementing unit.

STANDARD SPECIFICATION :

BRAND: GP 50 And Or Rosemount


MODEL: Model 312 and or 3051 Smart Pressure Transmitter
SENSOR TYPE: Diaphragm sensor
INSTALLATION LOCATION: Standpipe Manifold.
MEASURING RANGE: 0-10,000 psi (Re-rangeable SPAN from 0 - 2,000 psi to 0
- 10,000 psi)
SENSITIVITY: 0.5 psi
ACCURACY: +- 0.075% of SPAN
APPROVALS/CERTIFICATION: Explosion proof for Class I, Division I, Groups B, C, and D. Dust-Ignition Proof for
Class II and Class III, Division 1, Groups E, F, and G. Suitable for indoor and outdoor (NEMA 4X) hazardous

Technical Proposal Page 23


locations. Factory Sealed.

11. RETURN FLOW SENSOR

The return flow is monitored to provide early detection of abnormal flow of mud returns from the borehole.
An increase of return flow may indicate a kick or a decrease of return flow may indicate lost circulation.
The return flow sensor is located in the return flow line,or ditch. This may be an enclosed or open flow-line.
The encoder technology applied to this sensor offers unprecedented sensitivity and accuracy. To maintain
compatibility and exchangeability with legacy flow line sensors, a digital to analog I.S. circuitry is built into the
sensor thus making the industry de facto standard 4-20 mA loop-powered type sensor connection.

SPECIFICATIONS:

GENERIC DESCRIPTION: Return Flow Sensor


SENSOR TYPE:
High-resolution absolute encoder to measure angular displacement of paddle.
LOCATION:
Return Mud Flow Pipe (covered or open-trough)
MEASURING RANGE:
0-100% Flow (0-90º paddle deflection)
PRECISION:
0.079% Flow (10-bits over 90º)
REPEATABILITY:
0.158% Flow
OPERATING TEMPERATURE:
-20 to 60 °C (-4 to 140 °F), Encoder (ambient)
-40 to 135 °C (-40 to 275 °F), In-process components
HUMIDITY: Up to 98%
APPROVALS/CERTIFICATION: Cert No. 07ATEX6248; Ex ia IIC T4, II 1G

12. MUD TEMPERATURE IN / OUT SENSORS

Temperature is measured directly at two locations:


1. At the flowline or possum belly to measure the temperature of the mud coming out from the borehole, and
2. In the Active Pit/tank to measure the temperature of the mud that is going into the borehole.
Through PMT system, differential temperature and thermal gradient may be performed.

Technical Proposal Page 24


SPECIFICATIONS:

BRAND: Rosemount And Or Other


MODEL: Programmable Temperature Transmitter
SENSOR TYPE: Platinum and Nickel RTD
INSTALLATION LOCATION: Active Pit, Possum Belly or Flowline
(Divider)
MEASURING RANGE: 0-300ºC (0-572ºF)
ACCURACY: 0.3ºC (0.54ºF)
SIGNAL OUTPUT : 10 MV /°F
APPROVALS/CERTIFICATION: Explosion-Proof for Class I, Division
1, Groups B, C, & D.

13. MUD DENSITY IN / OUT SENSORS

Differential Pressure is measured between two pressure sensitive diaphragms. Housings are built for mud
weight in and mud weight out locations. Through PMT software, calculations of differential mud weight and
Equivalent Circulating Density (ECD) may be calculated.

SPECIFICATION :

BRAND: Rosemount And or Other


MODEL: Pressure Transmitter
SENSOR TYPE: Diaphragm – Piezo-resistive Silicon Sensor
INSTALLATION LOCATION: Active Mud Tank or Ditch / Possum Belly.
MEASURING RANGE: -20.59 to 31.29 inches H2O (true sensor set range)
0-20 ppg (as set in PMT )
PRINCIPLE OF PURPOSE : Differential pressure measurement between two
vertically separated points in drilling fluid
SIGNAL OUPUT : 4 - 20ma
MEASUREMENT PURPOSE : Density of Drilling Fluid

Technical Proposal Page 25


14. GAS DETECTION SYSTEM

1. GAS TRAP

The all stainless steel extractor is ruggedly built and can be easily installed and adjusted in height while it’s
working in position. With its uniquely designed impeller system, the gas extractor can maintain steady
flow of drilling mud through the extractor even with a substantial variation in the shaker tank level. This
helps ensure a meaningful and consistent gas reading. Supply with AC Voltage 220/380 Vac.

AGITATOR MOTOR:

BRAND: Marathon
MAXIMUM SPEED: 1725 RPM
350 RPM (at maximum Torque)
MAXIMUM TORQUE: 26.1 lb-in. or 3.05 Nm
19.5 lb-in. or 2.2 Nm (at maximum RPM)

OPTION 2: CONSTANT VOLUME DEGASSER

Agitator:

Constant Mud Flow 2 liters or 3 liters/min .It is for online.

Istalltion near possum belly or on the side of the shale shakers.

DEGASSER MOTOR:
Power supply: Single-Phase 220VAC
Three Phase 220-240VAC 380-420VAC 50Hz-60Hz/370W

Certification:Ex dII BT4 and 05 ATEX 1420

Technical Proposal Page 26


2. GAS CHROMATOGRAPH

PMT use the gas chromatograph detector: which use FID detector and online gas detecting and analysis
system with alarm
Manufactured by: Baseline
 Model: 8900 Mocon
 Analyses Cicle: the required for the elution of the pentanes (C1 – C5) 1 cycle :30 second,
components C1, C2 and C3 must touch the baseline line as well as components of total C4
and C5
Automatic gas sample backflush and accuracy and sensitivity 2-10 ppm

3. TOTAL GAS

DESCRIPTION:

1. Model BASELINE MOCON 8800 Total Hydrocarbon Monitor


2. FID Hydrogen Flame Detector.
3. Sensitivities not affected by mud additives
4. LED Display on front panel for flow and total units
5. High & Low Alarm settings available.

SPECIFICATIONS:
OPERATING RANGE: 0-10,000 units or 0-200% Methane (C1) equivalent
SENSITIVITY: 0.1 unit (0.02% by volume concentration)

Technical Proposal Page 27


4. GAS NON – HYDROCARBON ANALYZER

a. Measuring : H2S, CO2


b. Measuring range : H2S : 0 - 100 ppm (Accuracy and sensitivity 1ppm)
CO2 : 0.01 – 100 % (Accuracy 0.5% and sensitivity 0.1%)

15. GEOLOGICAL ANALYSIS EQUIPMENTS

1. BINOCULAR ZOOM MICROSCOPE


Two good quality A 5 X 50 Electrical Zoom binocular microscope with 2(two) light sources connect PC
and could be seen with camera and extremely good optic and rugged design.
Standard set of chemical and glassware for cutting and core analysis.

Technical Proposal Page 28


2. FLUOROSCOPE , ULTRAVUIOLET TUBES VIEWING BOX
Ultra violet fluoroscope, with detachable head for the examination of cores. Good quality, rugged
design, with removable side doors for easy access.

3. DRYING OVEN
PMT designed and built convection oven, With the Element method. Rugged and very Reliable. Fast
drying. Temperature could be reached 240° C

4. CALCIMETRI KIT WITH BUILT-IN RECORDER

 Measuring range: 0~100% carbonate


 Precision: 1%
 Lucite cell and gauge
 Stainless steel carrying case
 Chemicals
 Mortar and pestle
 Recorder and graph paper

Technical Proposal Page 29


5. SHALE DENSITY
A safe and accurate way to determine shale density without the use of poisonous chemicals.
• Simple
• Accurate
• Safe
• Precise

6. Cutting Preparation and Description tools ( sieves, sample tray, ceramic plate, chisel , hammer,
tweezers , grain size charts, color charts, hydrochloric acid, alizarin red, iso propanol, chloroform,
and other chemicals to discern rock types, etc ) and wax dip tank for cores preservation.

7. MISCELLANEOUS SUPPORTING EQUIPMENT AND CONSUMABLES


 Intercom system among Mud Logging Unit, Rig Floor, Mud Engineer Laboratory and Company
Drilling Representative
 Refrigerator
 Fire Extinguisher
 Video Camera is mounted on the rig floor and can be seen by monitor in the Mud Logging Unit
Cabin and Company
Room also Company’s Jakarta Office.
Sample packaging kit including : dried sample envelope, dried sample box, tray , cloth and
computer supplies including printer / plotter ink, papers and usb disk

Technical Proposal Page 30

Vous aimerez peut-être aussi