DIALOG E &C ‘SDN. BHD. PROJECT OWNER: PROJECT TITLE: DOCUMENT TITLE: DOCUMENT NUMBER: Doc No: DH1349-ENG-PI-CL-0001 Rev No: A CALCULATION Date: 26-Apr-13 Page: 1 of 4 PUMA ENERGY PVT LTD EPCC OF BITUMEN TERMINAL IN TANJUNG LANGSAT, MALAYSIA WALL THICKNESS CALCULATION B 31.3 (INTERNAL PRESSURE) DH1349-ENG-PI-CL-0001 ISSUED FOR REVIEW CRA DH1349-ENG-PI-CL-0001 eymerc] CALCULATION i 26-Apr-2013 DIALOG E & C Eee or ‘SDN. BHD. 1.0 PIPE WALL THICKNESS CALCULATION FORMULA STRAIGHT PIPE UNDER INTERNAL PRESSURE Design Code ASME B31,3, Process Piping ‘Symbols tm a Minimum required thickness, including mechanical, corrosion and erosion allowances. Pressure design thickness, as calculated in accordance with para. 304.1.2 for internal pressure or as determined in accordance with para, 304.1.3 for external pressure. ‘Sum of mechanical allowances (thread or groove depth) plus corrosion and erosion allowances. For threaded components, the nominal thread depth (dimension h of ASME 1.20.1, or equivalent) shall apply. For machined surfaces or grooves where the tolerance is not specified, the tolerance shall be assumed to be 0.5-mm in addition to the specified depth of the cut. Corrosion allowance assumed, mm. Inside diameter of pipe. For pressure design calculation, the inside diameter of the pipe is the maximum value allowable under the purchase specification. Internal design gauge pressure. Outside diameter of pipe as listed in tables of standards or specifications or as measured. Quality factor from Table A-1A or A-1B. Stress value for material from Table A-1A. Pipe wall thickness (measured or minimum in accordance with the purchase specification). Coefficient from Table 304.1.1, valid for t< D/6 and for materials shown. The value of Y may be interpolated for intermediate temperatures. Fort >=Di6, Y= (d+2c)/(D+d+2c) Mill under-tolerance ASME B31.3 Para, 304.1.2 Straight Pipe Under Internal Pressure Fort

Vous aimerez peut-être aussi