Vous êtes sur la page 1sur 2

PRODUCT LEAFLET

Current transformer LVB/IMT 40.5 - 550 kV


Reliable and safe outdoor instrument transformers

Current transformer LVB/IMT


product range is based on top core
design. It is an oil-paper insulated
type with a metallic expansion
bellow instrument transformer. The
products are mainly used for
outdoor installations. It is a reliable
product with minimum maintenance
and suitable for wide range of
environmental conditions.

Features Benefits
Ÿ Designed and tested in accordance with latest IEC Ÿ Easy installation and commissioning
specification Ÿ Maximum reliability and minimal maintenance
Ÿ High accuracy and reliable design Ÿ Suitable for wide range of environmental
Ÿ Safe sealing slows the aging process and extends conditions
product life Ÿ Good seismic performance
Ÿ Corrosion resistance: stainless steel expansion
bellows and cast aluminum oil tank and basement


Technical data

Type LVB-40.5 LVB-126 LVB-252 IMT-420 IMT-550


Highest voltage kV 40.5 126 252 420 550
2×50-2×2000, 2×50-2×2000, 2×50-2×2000, 2×50-2×2000, 2×50-2×2000,
Rated current A
100-4000 100-4000 100-4000 100-4000 100-4000
Short-time thermal current kA/s 31.5/1- 50/3 31.5/1- 50/3 50-63/3 50-63/3 50-63/3
Rated dynamic current kA 80-125 80-125 80-160 125-171 125-171
Rated insulation level kV 40.5/95/200 126/230/550 252/460/1050 420/630/1050/1425 550/740/1300/1675
Dielectric dissipation factor \ ≤0.005 ≤0.005 ≤0.005 ≤0.004 ≤0.004
Rated sencondary current A 1, 5
Rated frequency Hz 50/60
Measurement and protection IEC 61869-2: 0.1, 0.2S, 0.5S, 0.2, 0.5/5P, 5PR, 10P, 10PR, PX, PXR, TPZ, TPX, TPY
\
accuracy class IEEE C57.13: 0.15, 0.15S, 0.3, 0.6, 1.2/C100, C200, C400, C800, X

Rated burden and instrument


\ 1-200 VA, Fs≤5
security factor of measuring class

Rated burden and accuracy


\ 1-200 VA, 5P10-5P40/10P10-10P40
limit factor of protective class
Insulator creepage distance mm/kV ≥25, 31
Other standard/regulation and values on request

Dimensions
LVB-40.5 LVB-126 LVB-252 IMT-420 IMT-550
1675 2375 3790 6250 6950
A
-- -- -- 5595 6195
1125 1825 3080 5220 5920
B
-- -- -- 4620 5220
C 220 220 285 400 400
D 475 475 600 600 600
E Φ20 Φ 20 Φ24 Φ28 Φ28
Note: Above are typical dimensions, dimensions may adjust upon varies rating and configuration.
All dimensions are in mm.

IMT-550
1
2

IMT-420 3

1
2 P2 P1

3
4

P2 P1

LVB-252 4
1
2
3

A±20
P2 P1
5
B±20
5
A±20

LVB-126 4
B±20

1
2
A±20

3
LVB-40.5
1 P2 P1
B±20

5
2
4
3
A±20

P2 P1
B±20

5
A±20

4
6
B±20

5
6 6 6 6 7
7 7 7
7 8
8
C
C

8 8
C

8
C

Copyright 2019 ABB. All rights reserved.

D×D 4×E D×D 4×E D×D 4×E D×D 4×E D×D 4×E

No. 1 2 3 4 5 6 7 8

Oil-level Primary Secondary


Name Expander Shell Bushing Nameplate Base
indicator terminal terminal box
C
2GSE000003-Rev.A, en, 2019-03

— —
ABB Jiangsu Jingke Note: We reserve the right to make technical changes or modify the
Instrument Transformer Co., Ltd. contents of this document without prior notice. With regard to purchase
No.9 Gucheng Road, Su-Su Industrial Park, orders, the agreed particulars shall prevail. ABB does not accept any
Suqian, Jiangsu Province, 223800, P.R. China responsibility whatsoever for potential errors or possible lack of
Tel: +86 527 8288 0886 information in this document.
Fax: +86 527 8288 0868
We reserve all rights in this document and in the subject matter and
www.abb.com.cn illustrations contained therein. Any reproduction, disclosure to third
www.abb.com/highvoltage parties or utilization of its content- in whole or in parts - is forbidden
without ABB's prior written consent.