0 évaluation0% ont trouvé ce document utile (0 vote)
103 vues2 pages
This document describes the design of an unlined canal using Kennedy's theory. It provides input parameters such as discharge, roughness coefficient, and bed slope. The critical velocity, calculated area, width, and other hydraulic properties are then calculated. The results are checked for scouring or silting based on the value of m. The design is repeated with a new depth value if scouring or silting conditions are found. The final design result lists the base width, height, and mean velocity of the canal.
Description originale:
Kennedy's Design of unlined canal for trapezoidal section.
It helps in determining the design width and depth of canal through trial and error method.
This document describes the design of an unlined canal using Kennedy's theory. It provides input parameters such as discharge, roughness coefficient, and bed slope. The critical velocity, calculated area, width, and other hydraulic properties are then calculated. The results are checked for scouring or silting based on the value of m. The design is repeated with a new depth value if scouring or silting conditions are found. The final design result lists the base width, height, and mean velocity of the canal.
This document describes the design of an unlined canal using Kennedy's theory. It provides input parameters such as discharge, roughness coefficient, and bed slope. The critical velocity, calculated area, width, and other hydraulic properties are then calculated. The results are checked for scouring or silting based on the value of m. The design is repeated with a new depth value if scouring or silting conditions are found. The final design result lists the base width, height, and mean velocity of the canal.
Calculated Area (A) = #DIV/0! sq.m Calculated Width of canal (B) = #DIV/0! m Design Area (A`) = #DIV/0! sq.m Wetted Perimeter (W.P) = #DIV/0! m Hydraulic Radius (R) = #DIV/0! m Chezy's Constant using Kutter's formula = #DIV/0! Nil Mean Velocity (V) = #DIV/0! m/sec Cross Check Designed C.V.R (m) = #DIV/0! #DIV/0! Remark: Check the value of m for scouring and silting A. More than 1 = Scouring >1 B. Less than 1 = Silting <1 C. Equal to 1 = Zero S & S 1 Repeat with new value for D if Condition A and B prevails Design Complete Re-Design Design Result
Design Result Base Width #DIV/0! m Height #DIV/0! m Mean Velocity #DIV/0! m/sec
Prepared By: Sanjit, Associate Lecturer,
Department of Civil Engineering and Surveying, Jigme Namgyel Engineering College