5.3.2.1 Low-Hydrogen Electrode Storage Condi-
tions. All electrodes having low-hydrogen coverings con-
forming to AWS AS5.{ and AWS AS.5 shall be purchased
in hermetically sealed containers or shall be baked by the
user in conformance with 5.3.2.4 prior to use. Immedi-
ately after opening the hermetically sealed container,
electrodes shal] be stored in ovens held at a temperature
of at least 250°F [120°C]. Electrodes shall be rebaked no
more than once. Electrodes that have been wet shall not
be used.
5.3.2.2, Approved Atmospheric Time Periods. After
hermetically sealed containers are opened or after elec-
trodes are removed from baking or storage ovens, the
electrode exposure to the atmosphere shall not exceed the
values shown in column A, Table 5,1, for the specific
electrode classification with optional supplemental desig-
nators, where applicable. Electrodes exposed to the atmo-
sphere for periods less than those allowed by column A,
Table 5.1 may be returned to a holding oven maintained
at 250°F [120°C] min.; after a minimum hold period of
four hours at 250°F [120°C] min. the electrodes may be
reissued.
5.3.2.3 Alternative Atmospheric Exposure Time
Periods Established by Tests. The alternative exposure
time values shown in column B in Table 5.1 may be used
provided testing establishes the maximum allowable time.
The testing shall be performed in conformance with AWS.
AS.5 for each electrode classification and each electrode
manufacturer, Such tests shall establish that the maximum
moisture content values of AWS AS.5 are not exceeded.
Additionally, ETOXX or E7OXX-X (AWS AS.1 or A5.5)
low-hydrogen electrode coverings shall be limited to a
maximum moisture content not exceeding 0.4% by weight.
These electrodes shall not be used at relative humidity-
temperature combinations that exceed either the relative
humidity or moisture content in the air that prevailed
during the testing program.