Subject: Tentative BOQ for General Civil works of FGD package at VSTPP
Major Scope of Supply: Only Cement and Rebar shall be supplied by L&T
Sr. No ITEM DESCRIPTION UOM Qty Unit Rate in INR Total Amount in INR
1 EXCAVATION
Earthwork / Weathered Rock in excavation upto 5.0m depth below FGL. Highly to
1.1
moderately weathered rock.
Cum 406,620
2 BACKFILLING
a) Filling using selected available excavated earth (from within plant boundary) and / or
borrowed earth / moorum in trenches, plinths, sides of foundations and other
underground structures, area filling etc. in layers not exceeding 250mm loose thickness
2.1 (higher thickness of layers upto 500mm with heavy mechanical compacting equipment) Cum 337,263
including lead upto 500m and all lifts and including loading from stock pile, carting,
unloading, filling, watering and compacting each layer etc. all complete as per
specification, drawings and as directed by the Purchaser / Engineer.
DISPOSAL Disposal of all types of surplus excavated earth within/outside plant
3 boundary etc. all complete as per specification, drawing and instructions of the Cum 58,723
Purchaser / Engineer.
4 SOLING
Boulder filling in plinths, area paving, grade slab of buildings and other under ground
structures with 150/230/250 mm thick rubble soling, 63 mm down graded hard stone
aggregate per IRC specification, in layers not exceeding 200mm in loose thickness
4.1 including breaking of boulders to required sizes, filling the interstices with selected Cum 11,278
sand/moorum and compacting to 85% 90% of the original volume of stone stack
standard proctor density & filling the intertrices of aggregate by sand for all lifts etc. all
complete as per specifications, drawings and as directed by the Purchaser / Engineer.
GRAVEL FILLING Gravel filling in Transformer pits, with clean 40 mm nominal size
stone including preparation of sub-grade, sieving and cleaning of boulders (without any
5
binding material and compaction) including cost of the material, royalties etc. complete
Cum 175
as per specifications, drawings and instructions of the Purchaser / Engineer.
PCC Supplying and laying Nominal Mix Plain Cement Concrete using graded aggregate
at all levels for all kinds of work like mass concrete, bed blocks, lean concrete, mud mat,
6 filling, etc. including labour, materials, equipment, handling, transporting, batching,
curing, testing, etc. all complete as per specification, drawings and instructions of the
Purchaser / Engineer but excluding shuttering work.
6.1 1:3:6 (with 40mm nominal size graded aggregate) - M10 Cum 9,323
RCC Supplying and laying Design Mix Cement Concrete for reinforced concrete work
at all levels for all kinds of work, including labour, materials, equipment, handling,
7 transporting, batching, mixing, controlling temperature, placing, levelling, compacting,
curing, testing, etc. all complete as per specification, drawings and instructions of the
Purchaser / Engineer, but excluding centering, shuttering and reinforcement work.
7.11 M-25 (20mm nominal size graded stone aggregate). Cum 582
M-30 (concrete with admixture if required (excluding the cost of admixture) and 20mm
7.12
nominal size graded stone aggregate).
Cum 53,407
7.21 M-20 (with 20mm nominal size graded stone aggregate). Cum 4,590
7.22 M-25 (with 20mm nominal size graded stone aggregate). Cum 3,948
7.23 M-30 (with 20mm nominal size graded stone aggregate). Cum 7,614
8 GROUT
Supplying and laying ready mix non-shrink flowable cementitious grout (minimum 50
mm thickness) of approved quality and proven make, mixed in required proportion with
8.1
water, etc. all complete as per manufacturers specifications, drawings and direction of
Cum 126
the Engineer. (M30 minimum)
SHUTTERING Supplying and fixing formwork of approved quality for cast-in-situ,
plain or reinforced concrete works of any type and section (including curved surfaces) at
all elevations, including labour, materials, equipment, shoring, strutting, scaffolding,
9 staging, tieing, nailing, caulking, bolting, testing, etc., and removal of formwork and
staging, design and preparation of working drawings of scaffolding and support
structures etc. all complete as per specification, drawings and instructions of the
Purchaser / Engineer.
10 REINFORCEMENT BAR
Placing of High yield strength deformed bars (Fe 500D / Fe500) conforming to IS 1786
Thermo Mechanically Treated (TMT) reinforcement, in reinforced concrete and allied
works, at all levels, including transportation, cleaning, straightening, cutting, bending,
binding in position with annealed wire and/or welding, Supplying concrete cover blocks,
10.1
pins, separators, chairs, supports for reinforcement, etc., with all materials, labour,
MT 6,503
equipment, handling, transporting, testing etc., preparation of bar bending drawings and
schedules all complete as per specifications, design drawings and instructions of the
Purchaser / Engineer.
11 BRICKWORK
12 PLASTER
12.1 12mm thick in cement sand mortor (1:6) - Internal (smooth) surface of walls Sqm 9,125
18mm thick cement plaster in 2 layers: 1st layer - 12mm thick plaster in cement sand
12.2 mortar (1:6) and 2nd layer (finishing) - 6mm thick plaster in cement sand mortar (1:4). - Sqm 9,030
External (rough) surface of walls
6mm thick cement stand plaster (1:4) on all RCC ceilings (except areas provided with
12.3
false ceilings and cable vault ceiling).
Sqm 8,435
13 PAINTING
Internal Painting (for Air - conditioned areas) with 2mm of polymer based water
13.1 resistant purry and minimum 2 coats of acrylic emulsion paint. All other areas shall be Sqm 4,195
applied with minimum 2 coats of Acrylic distemper.
Internal Painting (for other areas) with 2mm of polymer based water resistant purry and
13.2
minimum 2 coats of Acrylic distemper.
Sqm 3,830
Internal Painting (for Ceilings except AC areas & battery rooms) with min. two (2) coats
13.3
of Acrylic distemper.
Sqm 9,049
External painting with resin / polymer bonded granular textured coating finish of 2.5
mm (natural coloured graded stone chips ), of approved colour, and shade for all types of
plastered and / or exposed concrete surface, in all kinds of works, at all levels, including
13.4 preparation of surface, preparation of working drawing, labour, material, equipment, Sqm 8,794
handling, transportation, mixing, laying, applying finishing, testing, curing, making
grooves, scaffolding, staging, etc., all complete, as per specifications, drawings and
instructions of the Engineer-in-charge.
13.41 PAINTING EXTERNAL (SYNTHETIC RESIN EMULSION) 2 coats Sqm 414
Acid/Alkali Resistant Paint With Two Coats Of Acid/Alkali Resistant Chlorinated
13.5
Rubber Paint Over Suitable Primer.
Sqm 210
14 FLOORING & FLOOR FINISHES
IPS (Cement concrete flooring) with Concrete hardener
14.1 topping.12mm thick with ordinary grey cement using uniformly Sqm 503
graded, properly treated iron particles.
IPS with dust proof NON-metallic hardener topping of total thickness 50mm above M20
14.2
PCC bed.
Sqm 6,257
9.5mm (min.) thick vitrified ceramic tiles in combination of mirror polished with 3 mm
groove joints as per approved pattern, pointed neatly with 3X4mm stainless epoxy grout
14.3
SP- 100 of Laticrete or approved equivalent in approved colour to match colour of tile
Sqm 222
fixed with 18mm thk cement sand mortar 1:4 above M20 PCC bed.
Battery room - 1 layer of bitumen primer followed by 12 mm thk bituminastic layer,
20mm thick acid resistant tiles, 6mm thk under bed by potassium silicate mortar, 6mm
14.4
thk poinding of joints of tiles with acid/alkali resistant epoxy/furane mortar up to a
Sqm 78
depth of 20mm and bituminastic end sealing.
18 thk polished KOTA stone flooring at entrance area, entrance steps and straircase
14.5
(tread, riser, landings, skirting).
Sqm 185
15 FALSE CEILING
Steel doors with double plate flush door shutters (45 mm thick) with two outer sheets of
18 G rigidly connected with continuous vertical 20 G stiffeners at the rate of 150 mm
16.1
centre to centre. Side, top and bottom edges of shutters shall be reinforced by
Sqm 10
continuous pressed steel channel with minimum 18 G.
16.2 Aluminium doors (Anodised) incl. glazing (min 6mm thk. Clear toughened glass) Sqm 16
16.3 Aluminium Windows (Anodised) incl. glazing (min 6mm thk. Clear toughened glass) Sqm 158
Fire proof door with double vocer plated type with moneral wool insulation - min 2
16.6
hours fire rating
Sqm 9
Metal deck roof troughed permanently colour coated Galvanised coloured MS Metal
17.3
decking (Min 0.8MM bare metal thickness).
Sqm 1,378
For MCC rooms, penthouse etc: 1st layer - Polymerised mastic over RCC roof. 2nd layer
- high solid content liquid applied urethane based elsatomeric water proofing membrane
18.1 of minimum 1.5mm thk. 3rd layer of screed concrete M15 with 25mm thick cement Sqm 4,656
mortar topping. 4th layer - wearing coarse with 25mm M15 PCC with joint sealing
elastomeric water proofing membrane.
Medium class galvanised mild steel pipes conforming to IS: 1239/ IS: 3589 with welded
19.1
joints with suitable C.I. grating at inlet point.
RM 1,902
24 PILES
Piles - Bored cast in-situ 600 dia Quantity per pile: Length of empty boring =27m;
24.1
Concrete M25 =7.07Cum; Reinforcement = 0.60Mt; Chipping Length = 1m;
Nos. 1,714
25 Pile testing
32 Road
250thk rubbel soling (63mm downgraded hard stone aggregate as per IRC spec.
32.3
watering and compaction to min. 90% standard proctor density).
Cum 675
32.4 Well compacted earth surface with CBR 10% Cum 1,350