Ceiling Joist
6” MAX
Acoustical Caulk
24”MAX
Resilmount
A237R
Wall Stud
Drywall
Floor
3” MAX
Acoustical Caulk
Figure 6.1: It is important to create a Figure 6.2: Install A237R with two Figure 6.3: Base board or any other wall
fire stop between rooms following local fasteners following local building codes. attachments must not touch the floor.
building codes.
WALL ASSEMBLY
Acoustical Caulk
6" MAX Drywall
Insulation
Stud Wall
Resilmount
A237R
Drywall Tape
and Joint
96" Compound
Hat Channel
3" MAX
16" Splicing Detail Acoustical Caulk
48"MAX See Figure 7.1
Acoustical
Sealant Drywall
Wood Studs
Insulation
24”o.c.
CEILING ASSEMBLY
Ceiling Joists
Resilmount
A237R
Clip to be 6"
maximum from
the end of channel
at ceiling perimeter
24" MAX
Hat Channel
8" MAX
16"
48"MAX
24 48
”M ”o
ax c
8” Wood Studs
Ma
x
Insulation
Fire Stop Drywall
Acoustical
Caulk Acoustical
Sealant
Corner Junction A
Steel Stud Wall Corner Junction B
Steel Stud Wall
1. Resilmount A237R
2. Drywall 1. Drywall
3. 7/8” Hat Channel (22 or 25 GA) 2. 7/8” Hat Channel (22 or 25 GA)
4. Steel Studs 3. Insulation
5. Insulation 4. Steel Studs
6. 1.5” x 1.5” Angle Gauge 5. Resilmount A237R