RESILMOUNT Architectural Drawings

Fire Stop 6” 24”


MAX MAX
See Figure 6.1

Ceiling Joist
6” MAX

Acoustical Caulk

24”MAX
Resilmount
A237R

Wall Stud

See Figure 6.2

Drywall

See Figure 6.3

Floor

3” MAX

Fire Stop Base


Molding 3” MAX
Acoustical
Caulk

Acoustical Caulk
Figure 6.1: It is important to create a Figure 6.2: Install A237R with two Figure 6.3: Base board or any other wall
fire stop between rooms following local fasteners following local building codes. attachments must not touch the floor.
building codes.

2900 Westinghouse Blvd. Suite 106 n Charlotte, NC 28273


Phone: (704) 504-1127 n Toll Free (888) 666-5090 n Fax (704) 504-1115 n www.soundisolationcompany.com 1 of 4
RESILMOUNT Architectural Drawings

WALL ASSEMBLY

Acoustical Caulk
6" MAX Drywall
Insulation

Stud Wall

Resilmount
A237R

Drywall Tape
and Joint
96" Compound

Hat Channel

24" MAX Floating


Base Board

3" MAX
16" Splicing Detail Acoustical Caulk
48"MAX See Figure 7.1

Acoustical
Sealant Drywall

Wood Studs

Insulation

24”o.c.

Figure 7.1: When splicing hat channel,


overlap 6 inches in between two A237R.
Secure the channel with two 7/16” framing Acoustical
Sealant 3”Max
screws or 18 gauge tie-wire can be used.

2900 Westinghouse Blvd. Suite 106 n Charlotte, NC 28273


Phone: (704) 504-1127 n Toll Free (888) 666-5090 n Fax (704) 504-1115 n www.soundisolationcompany.com 2 of 4
RESILMOUNT Architectural Drawings

CEILING ASSEMBLY

Ceiling Joists

Resilmount
A237R

Clip to be 6"
maximum from
the end of channel
at ceiling perimeter

24" MAX

Hat Channel
8" MAX

16"
48"MAX

24 48
”M ”o
ax c

8” Wood Studs
Ma
x
Insulation
Fire Stop Drywall
Acoustical
Caulk Acoustical
Sealant

Figure 8.1: It is important to create a fire stop


between rooms following local building codes.

2900 Westinghouse Blvd. Suite 106 n Charlotte, NC 28273


Phone: (704) 504-1127 n Toll Free (888) 666-5090 n Fax (704) 504-1115 n www.soundisolationcompany.com 3 of 4
RESILMOUNT Architectural Drawings

CORNER AND WALL INTERSECTION

Corner Junction A
Steel Stud Wall Corner Junction B
Steel Stud Wall
1. Resilmount A237R
2. Drywall 1. Drywall
3. 7/8” Hat Channel (22 or 25 GA) 2. 7/8” Hat Channel (22 or 25 GA)
4. Steel Studs 3. Insulation
5. Insulation 4. Steel Studs
6. 1.5” x 1.5” Angle Gauge 5. Resilmount A237R

Wall Intersection A Wall Intersection B


Steel Stud Wall Steel Stud Wall
Isolated Wall Intersects
1. Drywall to Non-Isolated Wall
2. 7/8” Hat Channel (22 or 25 GA) 1. Drywall
3. Resilmount A237R 2. 7/8” Hat Channel (22 or 25 GA)
4. Insulation 3. Resilmount A237R
5. Steel Studs 4. Steel Studs
5. Insulation