"NO CIDS 2 DATA" : CFDS FAULT MESSAGE

ATA: 23-73 FIN: Ref: 23.73.00.083


A/C Type: A319 A/C Serie: Potential First Issue 01-OCT-2002
A320 Impact: Date:
A321
Part Number: C12860AA02 Key Last 12-MAY-
(Std 9B) Information: Publication 2016
Z010H000 3 5/ Date:
113 117 118 119
520A 521A
B401ACM0507
(Std 8)
Supplier: THALES Solution
THALES AVS Benefit:
FRANCE SAS
KID SYSTEME
GMBH
THALES
AVIONICS
ELECTRICAL
Linked Articles: Linked
Documentation:
Linked FAIR- Status: Closed
ISP:

Engineering Support
Fault Code/ECAM Warning: NO CIDS2 DATA First Issue Date: 01-OCT-2002
NO CIDS1 DATA
Model: Last Publication Date: 12-MAY-2016
Manufacturer:
Status: Closed

Issue Description
Several operators have reported the CFDS fault messages "NO CIDS 2 DATA" and "NO
CIDS 2 DATA (INTM)" on the CFDS PLR/PFR on their A320Family aircraft. These
messages appear mainly during flight phase 2 and 6. There is no operational degradation
of the CIDS. This has been reported with all CIDS standards, i.e. with director PN
Z010H000XYYY; X=3,5 and Y=113,117,118,119,20A,21A, 22A and all CFDS standard.
Investigation Status
Following operators' reports, investigations were launched by Airbus together with CIDS
Supplier (Airbus-Buxtehude). Specific conditions of occurrence (Short Power Interrupt) of
the failure message were determined in flight phase 2.
In service trial, flight test and laboratory testing have allowed to identify another
condition of occurrence. It has been confirmed that a 'NO CIDS 2 DATA' fault message
may be triggered when the pilot performs an Attendant Call towards the Forward cabin
attendant station.
This scenario has been confirmed during in depth lab testing. When Forward Attendant
Call is computed by the CIDS, the audio board of the Director 2 is activated and its
internal logic may lead to the loss of its ARINC communication with the CFDS.
Since there is no Classic CIDS OBRM software update scheduled, Airbus recommend
filtering the CFDS messages as per SIL 00-028.
Mitigation / Interim Plan
Airbus recommend to filter the CFDS messages "NO CIDS 2 DATA" and "NO CIDS 2 DATA
(INTM)". This does not lead to a hidden failure since in case of Director 2 failure the
warning indication will also trigger a maintenance status "CIDS 2" on lower ECAM.
Subject recommendation is available in SIL 00-028.
Maintenance Information
N/A
Solution
Since there is no Classic CIDS OBRM software update scheduled, Airbus recommend
filtering the CFDS messages as per SIL 00-028.

Survey for the Engineering Support section

© Airbus SAS, 2018. All rights reserved. Confidential and proprietary document.The technical information
provided in this article is for convenience and information purposes only. It shall in no case replace the
official Airbus technical or Flight Operations data which shall remain the sole basis for aircraft
maintenance and operation. These recommendations and information do not constitute a contractual
commitment, warranty or guarantee whatsoever. They shall not supersede the Airbus technical nor
operational documentation; should any deviation appear between this article and the Airbus or airline's
official manuals, the operator must ensure to cover it with the appropriate document such as TA, FCD,
RDAS. Access to WISE is supplied by Airbus under the express condition that Airbus hereby disclaims any
and all liability for the use made by the user of the information contained in WISE. It shall be used for
the user's own purposes only and shall not be reproduced or disclosed to any third party without the
prior consent of Airbus.

Vous aimerez peut-être aussi