Vous êtes sur la page 1sur 4

Productivity and Safety through

Mine-Spec digital applications

mine wide emergency


communications

Emergency evacuation warning

Personal paging

Remote blast initiation

Remote equipment control

MST Global reserves the right to make changes to the specifications and information contained in this
brochure at any time and without notice. B9MSTPED4ppUS
mine wide emergency
communications

Applications
EMERGENCY COMMUNICATIONS & MANAGEMENT
TEXT MESSAGING
TTE EQUIPMENT SWITCHING
WIRELESS CENTRALISED BLASTING

The MST Global (MST) Personal Emergency Device (PED®) enables PED to transmit directly through rock strata, so wherever
Communication System is based on ultra-low frequency personnel are in a mine, a message can reach them. This is possible
because it does not rely on line of sight to an antenna like other forms of
transmission that propagates through rock strata. The
communication.
PED® System has been in use in mines for over twenty-five
years and remains the only proven through-the-earth (TTE) The mine wide signal coverage of PED® also means it is very
communication system in use at mines. useful day to day communication system. Hence PED®
Refinements to the system over this time has further also stands for Productivity Enhancement Device. Should it be required
improved its reliability and functionality. It has in an emergency, the user has the peace of mine that the system is
already working.
been installed in over one hundred and fifty coal and
metalliferous mines around the world. PED® uses ultra low frequency (ULF) signals to send
signals directly through rock, so called “through-the-earth” (TTE)
The PED® System is an emergency warning system and a daily transmissions. The main difference between PED® and other
communication system rolled into one. PED® stands for Personal so called TTE systems is that PED® is proven and is operating in many
Emergency Device. The use of ultra low frequency (ULF) signals mines, 24 hours a day, 7 days a week.

Features and Benefits

PAGING EMERGENCY EVACUATION WARNING


­— PED® can send a 32 character text message to — Fast, simultaneous communication: emergency
an individual wherever they are underground. evacuation instructions can be sent simultaneously to
all personnel in only 15 seconds.
— PED® has been installed in many mines as their primary
EFFECTIVE COMMUNICATIONS evacuation system.
— For overall communications, PED® complements — A proven, reliable and effective system in emergency
existing phone and radio systems to maximize benefits situations.
to the mine operator.
REMOTE CONTROL
­ Ventilation fans, etc can be remotely switched on and

SAFER BLASTING off to reduce energy usage and manage pre and post-
— The BlastPED System uses the proven PED® blast fan use.
Transmission system to provide a safe and reliable
remote blast initiation system.
GIGABIT BACKBONE
­ Multi service capabilities today and a safe investment

for future technologies.
PED® for mine wide signal coverage
The PED® provides mine wide signal coverage. The ability of PED® to • Groups of miners can receive information, such as the reason
transmit through rock strata means it can truly deliver complete signal for a power failure or that the conveyor system is going to be
coverage to an underground mine. stopped outbye, etc.
This is achieved without the need of installing antenna cables in • A belt-man can be quickly advised of a problem that requires
every part of the mine (something more traditional ‘line-of-sight’ investigation (e.g. belt slip re-set).
radio systems would require). A relatively small antenna on the
• A transport driver can be advised of an urgently needed part.
surface, or underground, provides complete signal coverage (refer to
the operation schematic below). This signal coverage is achieved at a PED® is installed in many mines as the main emergency warning
fraction of the cost than any other type of radio system. system. In an emergency, messages can be sent to all personnel
simultaneously. Importantly not only does PED provide rapid warning,
Where other systems are vulnerable to rockfall, fire and general
it also provides specific instructions via text messaging
wear and tear, PED® greatly reduces these typical problems of
such as the nature of the emergency or evacuation routes to use.
unreliability and maintenance.
PED® allows the user to contact key personnel wherever they are. It PED® has been installed in over 150 mines since 1990. The system
can send a private text message to any individual, wherever they are has been refined and enhanced over this time, but the basic working
underground. principles remain the same. The ULF transmission system transmits to
a number of receiver types to allow a range of applications.
This simple, one-way text message can save time and money, for
example:

Ultra Low Frequency


signals transmitted through
rock strata
PED®
Loop ante nna
Hard Wire or (Sur face or
Optic Fibre Link Und ergr ound )
R S 2C3T2IO N
CONNE

PED® Modulator with PED® ULF Transmission


Emergency Message Headend The Personal Receiver
Buttons ensures all messages are
Windows PC running clearly received
PEDcall software for
entering messages

Fig1. The PED® Communications System Operation Schematic.

PERSONAL RECEIVER BLASTPED®


• Integrated with a miner’s cap lamp • The Blast PED is the receiver/exploder unit that
• This can be the ultra light weight allows for the remote initiation or firing of blasts
lithium ion battery pack, known as the • Specially coded signals are sent via the PED®
Integrated Communications Cap Lamp system that ensure the BlastPED receivers only
(ICCL) operate when required
• On receipt of a message, the cap lamp • This coding, and several other levels of physical
flashes, a buzzer sounds, and the 32 and software security, ensure the total safety of
character text message is illuminated the system
on a liquid crystal display • BlastPED is approved for use in a number of
• The PED® receivers always indicate that countries including Australia, USA and Canada
they and the transmission system are and is the only “radio” remote blasting system in
operating general use in underground mines

AUTOPED® CONTROLPED®
• AutoPED is a vehicle mounted receiver • The ContolPED is a receiver that allows the
to ensure personnel travelling in a remote switching of equipment, such as fans,
vehicle receive messages pumps, etc
• The large display on the AutoPED is • Typically interfaced to the Stop-Start
clearly visible to all occupants contacts in a device’s control panel
mine wide emergency
communications

TECHNICAL SPECIFICATIONS

TRANSMISSION SYSTEM RECEIVING DEVICES


TRANSMISSION HEADEND PERSONAL RECEIVER
Frequency ULF Display
Output Power 1.2kVA • 32 character message, graphics, LCD
Operating Temperature 0°C to 40°C AV • LED back light, Time display
• Message Storage (2), scroll facility
Power 110/240V - 60/50Hz AC
Dimensions Housed in 19 inch rack cabinet Alert Cap Lamp 10 second flash, buzzer
1200mm H x 600mm W x 600mm D (48″ x 24″ x 24″) Voltage Cap Lamp battery 7.4v (nominal)
Includes Earth leakage/ground fault detection and lockout Power 30mA
Weight 200g - 0.4lb
SOFTWARE
Rating IP65
PEDCALL® Operating Temperature -20°C to 50°C (-4°F to 120°F)
• Windows based main system software
Display Dimensions 70mm H x 220mm W x 80mm D (3″ x 9″ x 3″)
• Individual, groups and general broadcast
• Name search CONTROL PED® FOR FIXED EQUIPMENT
• Custom text messages
Power
• Message priority
• 110/240V - 60/50Hz AC
• Message log
• 24V AC or DC
• 15 second Emergency Message Facility
• Pre programmed messages generated at specific times can be networked Indicator LEDs
on mine’s LAN • Power ON / OFF
• Transmission Status
Mine Monitoring
Switching Relays 110V AC / 5amp
• Custom Interface to monitoring system for automatic message generation
Receiver dimensions 70mm H x 220mm W x 80mm D (3″ x 9″ x 3″)
• Monitors an unlimited number of input
• Programmable messages to predefined personnel and devices Antenna dimensions 170mm L x 30mm W x 30mm D (6.5″ x 1.2″ x 1.2″)

SMART EXTERNAL MODULATOR BLASTPED® REMOTE BLASTING SYSTEM

Power 110/240V - 60/50Hz AC Capacity Capable of firing 70 ohm series circuit


Input Serial interface from PC Security
Output 0 - 20mA to PED Headend • Individually coded receivers
• System access only via secure, external media
Features Emergency message buttons (3)
• Key/Switch to Receiver
• Independent supervisory circuit
• Sequenced command string
Indicator LEDs
• Battery Status, Receiver ready
• Arm, Blasted
Rating IP66
Dimensions 480mm H x 140mm Diameter (19″ H x 5.5″ Diameter)

MST offices and support centers are strategically www.mstglobal.com


located in the world’s primary mining regions. solutions@mstglobal.com

United States Australia Russia South Africa Chile China


Denver Sydney Moscow Centurion Santiago Hangzhou
Tel: +1 303 951 0570 Tel: +61 (0)2 9491 6500 Tel: +7 (499) 978 72 11 Tel: +27 12 345 6100 Tel: +56 (2) 2 656 7673 Tel: +86 571 8580 3320 Ext 206

Vous aimerez peut-être aussi