Subject : Data Inconsistency Check


Project : All
Originator : Umar Schadon
Approval : Umar Schadon
Date : 16-05-2014
Ref. No. :

On every pipe you should run a Data Consistency Check.

In the next pages you see the most common error messages with a brief description and
solution. You should try the get *-* NO DATA INCONSISTENCIES*-* as an end result.
Solve error, info missing on isometric.
Solve error, isometric will or could fail.
hange E hange E
XC di XC di
F- t F- t
PD

PD
or

or
!

!
W

W
O

O
N

N
Y

Y
U

U
B

B
Catalogue error, contact Gabriel Romijn ext. 571.
to

to
ww

ww
om

om
k

k
lic

lic
C

C
.c

.c
w

w
tr re tr re
.

.
ac ac
k e r- s o ft w a k e r- s o ft w a
Isometric will run without problems, you could solve error.

Branch Head Errors

A 10 HEAD REFERENCE NOT SET


(No connection reference on isometric. Connect branch head. If branches are within the
same pipe, isometric will fail.)

A 20 HEAD REFERENCE POINTS TO NONEXISTENT ELEMENT


(No connection reference on isometric. Reconnect branch head.)

A 30 BAD HEAD RETURN REFERENCE


(Connect tail of branch reference to your branch head or run interconnection macros.)

A150 HEAD TERMINAL PROBLEM, TERMINAL INCONSISTENT FLOW ACROSS


BRANCH CONNECTION
(Isometric will fail. Change the flow of your branch and connect branch head.)

A200 DIRECTION HDIR NOT SAME AS TERMINAL DIRECTION


(Isometric will fail. Change the HDIR on branch level or reconnect branch head.)

A210 POSITION HPOS NOT SAME AS TERMINAL POSITION


(Isometric could fail. Normally configuration looks funny. Reconnect branch head.)

A220 HBORE NOT SAME AS TERMINAL BORE


(Isometric could fail. Change HBOR on branch level or reconnect branch head)

A230 CONNECTION TYPE HCONN NOT SAME AS TERMINAL CONNECTION TYPE


(Isometric will run without problems. Change the HCONN on branch level according coco
table to solve error.)

E.g. Flange pl(eave) Branch head


FBB FBB

Branch tail GBB Gasket pa(rrive)


GBB

A410 HCONN NOT COMPATIBLE WITH CONNECTION TYPE OF HSTUBE


(Isometric could fail. Normally configuration looks funny. In most cases caused due to error
A210. Reconnect branch head or change the HCONN on branch level according coco table
to solve error.)

A430 INSULATION CANNOT BE SELECTED USING HBORE


(Isometric will run but no insulation is shown in the 3D model. Set TEMP on branch level or
reselect insulation according insulation spec.)
Branch Tail Errors

B 10 TAIL REFERENCE NOT SET


hange E hange E
XC di XC di
F- t F- t
PD

PD
or

or
!

!
W

W
O

O
N

N
Y

Y
U

U
(No connection reference on isometric. Connect branch tail. If branches are within the
B

B
to

to
ww

ww
om

om
k

k
lic

lic
same pipe, isometric will fail.)
C

C
.c

.c
w

w
tr e tr re
ar
.

.
ac ac
k e r- s o ft w k e r- s o ft w a

B 20 TAIL REFERENCE POINTS TO NONEXISTENT ELEMENT


(No connection reference on isometric. Reconnect branch tail.)

B 30 BAD TAIL RETURN REFERENCE


(Connect head of branch reference to your branch tail or run interconnection macros.)

B150 TAIL TERMINAL PROBLEM, TERMINAL INCONSISTENT FLOW ACROSS


BRANCH CONNECTION'
(Isometric will fail. Change the flow of your branch and connect branch tail.)

B200 DIRECTION TDIR NOT SAME AS TERMINAL DIRECTION


(Isometric will fail. Change the TDIR on branch level or reconnect branch tail.)

B210 POSITION TPOS NOT SAME AS TERMINAL POSITION


(Isometric could fail. Normally configuration looks funny. Reconnect branch tail.)

B220 TBORE NOT SAME AS TERMINAL BORE


(Isometric could fail. Change TBOR on branch level or reconnect branch tail)

B230 CONNECTION TYPE TCONN NOT SAME AS TERMINAL CONNECTION TYPE


(Isometric will run without problems. Change the TCONN on branch level according coco
table to solve error.)

E.g. Flange pl(eave) Branch head


FBB FBB

Branch tail GBB Gasket pa(rrive)


GBB

Plain Branch Errors


C530 HCONN IS NOT COMPATIBLE WITH TCONN
(Isometric will run without problems. Change the TCONN on branch level according coco
table to solve error.)

E.g. TUBI pl(eave) TUB Branch head


TUB

Branch tail TUB TUBI pa(rrive) TUB

C540 THIS BRANCH HAS NO COMPONENTS


(Isometric will run without problems. No action needed. You could solve this error; just add
a plain text atta in your branch.)

All Component Diagnostics


hange E hange E
XC di XC di
F- t F- t
PD

PD
or

or
!

!
W

W
O

O
N

N
Y

Y
U

U
B

B
to

to
ww

ww
om

om
k

k
lic

lic
D300 REFERENCE CREF NOT SET
C

C
.c

.c
w

w
tr re tr re
.

.
ac ac
k e r- s o ft w a k e r- s o ft w a

(In most cases no branch is connected to a TEE or OLET in your branch. If branches are
within the same pipe, isometric will fail.)

D400 ARRIVE TUBE [ROD] LESS THAN TUBE [ROD] MINIMUM. ACTUAL TUBE [ROD]
LENGTH IS ...
(Isometric will run but you should check the minimum distance and change that according
standard.)

D410 BAD ARRIVE GEOMETRY + details of geometric errors


(Isometric will fail. Connect your component to its previous component.)

D420 BAD ARRIVE BORE [ROD DIAMETER]


(Isometric could fail. Arrive bore of your component is different than leave bore of previous
component, reselect component.)

D430 BAD ARRIVE CONNECTION TYPE


(Isometric could fail. Arrive connection type of your component is different than leave
connection type of previous component. Reselect component. E.g. FLAN-FLAN should be
FLAN-GASK-FLAN)

D610 LEAVE CONNECTION TYPE NOT COMPATIBLE WITH CONNECTION TYPE OF


LSTUBE [LSROD]
(Isometric could fail. Leave connection type of your component is different than arrive
connection type of next component. Reselect component. E.g. FLAN-FLAN should be
FLAN-GASK-FLAN)

D620 INSULATION CANNOT BE SELECTED USING LEAVE BORE


(Isometric will run but no insulation is shown in the 3D-model. Set TEMP on branch level or
reselect insulation according insulation spec.)

D740 ANGLE OF COMPONENT IS GREATER THAN MAXIMUM ANGLE SPECIFIED IN


SPREF
(Isometric could fail. Change configuration .90deg. elbows cannot have an angle larger
than 90deg. Or in case of 45deg. elbows it could not be larger than 45 deg.

D740 ANGLE GREATER THAN m DEGREES. ACTUAL ANGLE IS n.


(Isometric could fail. Change configuration .90deg. elbows cannot have an angle larger
than 90deg. Or in case of 45deg. elbows it could not be larger than 45 deg.

D820 SKEY not set


D840 SKEY #N not known. Assumed to be user defined
(Isometric will run without problems. These are catalogue errors please contact Gabriel
Romijn
Ext.571)

End Component Diagnostics

E700 LEAVE TUBE LESS THAN TUBE MINIMUM. ACTUAL TUBE LENGTH IS ...
hange E hange E
XC di XC di
F- t F- t
PD

PD
or

or
!

!
W

W
O

O
N

N
Y

Y
U

U
(Isometric will run but you should check the minimum distance and change that according
B

B
to

to
ww

ww
om

om
k

k
lic

lic
standard.)
C

C
.c

.c
w

w
tr e tr re
ar
.

.
ac ac
k e r- s o ft w k e r- s o ft w a

E710 BAD LEAVE GEOMETRY


(Isometric could fail. Normally configuration looks funny. Reconnect branch tail.)

E720 LEAVE BORE NOT SAME AS TBORE


(Isometric could fail. Change TBOR on branch level or reconnect branch tail)

E730 LEAVE CONNECTION TYPE NOT COMPATIBLE WITH TCONN


(Isometric will run without problems. Change the TCONN on branch level according coco
table to solve error.)

E.g. Flange pl(eave) Branch head


FBB FBB

Branch tail GBB Gasget pa(rrive)


GBB