2/S13
oprema
10430 SAMOBOR
KRALJA KREŠIMIRA IV b.b.
HRVATSKA
TEL: (**385 1) 33 62 513
FAX: (**385 1) 33 62 905
INDEX
L B
E Connection detail F
ØD RZR 60
R
12.5
60
260
L - 48 B - 48
L + 42 B + 42
L B E F R ÆD Vn Vmin Vmax
3 3
(mm) (mm) (mm) (mm) (mm) (mm) (m / h) (m / h) (m3/ h)
DSP V 600 x 600 600 600 595 595 180 248 450 180 650
DSP V 1200 x 600 1200 600 1195 595 200 313 900 360 1300
DSP V 1800 x 600 1800 600 1795 595 200 2 x 313 1350 540 1950
DSP V 1200 x 1200 1200 1200 1195 1195 260 448 1800 720 2600
DSP V 1800 x 1200 1800 1200 1795 1195 320 558 2700 1080 3900
Characteristics
Perforated ceiling diffuser, type DSP, is normally used in ventilation and air-conditioning systems applied for up to 4 m high rooms
in which a large number of air changes is required with a minimum induction, that is rather uniform air-stream velocity and
temperature pattern being formed in the “occupied zone”.
In order to fulfil these requirements, the free outflow area of the diffuser is so large that relatively large supply air volume flow
rates produce small air velocity in the occupied zone. This velocity being vL » 0.25 m/s produces uniform air flow in the occupied
zone (“laminar flow”). The diffuser is therefore used for heating and cooling purposes within temperature differences of ±10 K.
Warm air stream (jet) is defined by isothermal jet data, while for the cold jet definition the jet acceleration due to temperature
difference between supply air and ambient room air has to be taken into account.
Construction
The diffuser consists of a plenum box, vertical round air connection (with or without RZR control damper), internal air distributor
for fine dispersion of air made of galvanized sheet steel, and carrying frame and outflow panels made of plastic coated sheet
steel (white - RAL 9010, other colors on special request). Within the plenum box the carrying steel frame is connected to holders
by means of bolts, while the outflow panels hang loose of the frame, so that the diffuser fits aesthetically well into the false ceiling
and in the room interior design in general.
2/S13-02
INDEX
Installation
The perforated ceiling diffuser DSP is mounted into ceiling openings of standard dimensions L x B, connected to the carrying
construction elements by means of hangers. The plenum box leans on the false suspended ceiling (what makes sealing
possible); see the detail drawing of the connection.
For DSP without RZR - omit the RZR in the order code
For other colors of frame and outflow panels - insert the RAL code in the brackets
Nomenclature:
2/S13-03
INDEX
12 00 120 x
1.0 18 DS
P 1800
60
P P DSP
DS DS 120
0
P
0.9
1200
DS
0.8
0.7
0.6
0.5
vef (m/s)
0.4
0.3
0.2
0.1
0.0
0
100
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
400
4000
200
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
600
300
500
800
900
3000
3100
3200
3300
3400
3500
3600
3700
3800
3900
700
. 3
V (m / h)
1.60
1.50
1.40
1.30
1.20
1.10
1.00 vef =
1.55
0.90 (m/
1. 4 s)
0.80 7
vL (m/s)
1. 38
7
0.70 1. 30
5
0.60 1. 22
4
1.14
0.50 1.06
0.40 0.98
0.30 0. 89
7
0.82
0.20
0. 7
0.10 0.5 0.661 34
14
0.00
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.5
h (m)
2/S13-04
INDEX
10
8°C
2°C
5°C
0°C
°C
0.40
0.35
0.30
vLH (m/s)
60
50
40
30
25
00
0x 6
20
60
15
0
x 60
00
00
12
Dptot (Pa)
10
x 12
x 60
9.0
00
00
00
8.0
18
18
x 12
7.0
00
6.0
12
5.0
4.0
3.0
2.5
2.0
100 200 250 300 400 500 1 000 2 000 3 000 4 000 6 000
. 3
V (m / h)
2/S13-05
INDEX
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
Frequency
30
25 Diffuser
LWA (dB)
1800x12 00
15
1200
DSP 1200x1200 13 -5 -12 -14 -14 -10
600
DSP 1800x1200 11 -5 -14 -14 -12 -11
1200x
00
00
10 1800x
6
0x
x6
60
00
12
5
100 200 300 500 1000 1500 2000 3000
.
V (m3/ h)
0.50
0.45
0.40
DtL
DtZ
0.35
0.30
0.25
0.20
0.0 0.5 1.0 1.5 2.0
h (m)
2/S13-06
INDEX
7. Induction i
Induction i = Vuk / VZ
7.0
6.0
5.0
Induction i
4.0
3.0
2.0
1.0
0.0
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
Distance h (m)
2/S13-07