PROJECT LPG STORAGE BULLET FOR KANDLA (U2 CERTIFICATION)

JOB NO. 3260

OWNER Vijay Tanks & Vessels (P) Ltd. EQPT. NO. LPG-BT-001

INSPECTION Lloyd's Register Verification Ltd. DOC. NO. 3260-LPG-BT-001-CAL-001 Rev. No. 01

7. MAWP SUMMARY DATE 24-02-19

Table-2 - MAWP of Shell & Head

MAWP MAPnc
(Mpa) (Mpa)
Component Remarks
At Ambient
At Design Temp (82 Deg)
(40 Deg)

Shell 2.14 2.27 Refer Chapter-5

Dishend 2.38 2.56 Refer Chapter-6

Minimum MAWP (Mpa) = 2.14 2.27

Table-3 - MAWP of Standard Flanges


Flange Working Pressure
Applicable (As per B16.5) Check for Flange Rating
Applicable Pressure Mpa (Whether MAWP <
Nozzle RATING(#) Applicable Standard for Flange
Material Group Temperature Flange Working
At Design Temp At Ambient
Rating Table Pressure Permitted)
(82 Deg C) (40 Deg C)

N1 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

N2 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

N3 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

N4 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

N5 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

N6 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

CN1 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

CN2 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

CN3 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

CN4 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

CN5 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

CN6 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

CN7 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

M1 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

M2 300# ASME B16.5 ED.2013 GROUP 1.1 Table 2.1.1 4.79 4.74 YES. SAFE

Minimum MAWP (Mpa) = 4.79 4.74

SHEET of 95
PROJECT LPG STORAGE BULLET FOR KANDLA (U2 CERTIFICATION)
JOB NO. 3260

OWNER Vijay Tanks & Vessels (P) Ltd. EQPT. NO. LPG-BT-001

INSPECTION Lloyd's Register Verification Ltd. DOC. NO. 3260-LPG-BT-001-CAL-001 Rev. No. 01

7. MAWP SUMMARY DATE 24-02-19

Table-4 - MAWP of Nozzle Reinforcement

MAWP
R.F. Pad Projection
(Mpa)
Size
Nozzle REMARKS
(NPS) At Design Temp At Ambient
O.D. Thickness Outside Inside
(82 Deg C) (40 Deg C)

Refer.Table-7,Chapter-
N1 4 215 25 373 0 2.15 -
10

Refer.Table-7,Chapter-
N2 8 420 25 486 0 2.15 -
10

Refer.Table-7,Chapter-
N3 6 320 25 492 0 2.15 -
10

Refer.Table-7,Chapter-
N4 2 - - 391 0 1.98 -
10

Refer.Table-7,Chapter-
N5 2 - - 519 0 1.98 -
10

Refer.Table-7,Chapter-
N6 8 420 25 481 0 2.15 -
10

Refer.Table-7,Chapter-
CN1 2 - - 392 0 1.98 -
10

Refer.Table-7,Chapter-
CN2 2 - - 394 0 1.98 -
10

Refer.Table-7,Chapter-
CN3 2 - - 396 3300 2.15 -
10

Refer.Table-7,Chapter-
CN4 2 - - 397 3300 2.15 -
10

Refer.Table-7,Chapter-
CN5 4 215 25 496 3300 2.15 -
10

Refer.Table-7,Chapter-
CN6 4 215 25 499 3300 2.15 -
10

Refer.Table-7,Chapter-
CN7 4 215 25 502 3300 2.15 -
10

Refer.Table-7,Chapter-
M1 24 1060 25 410 0 2.14 -
10

Refer.Table-7,Chapter-
M2 24 1060 25 301 0 2.14 -
10

Minimum MAWP (Mpa) = 1.98 -

Mawp summary
MAWP
Component (Mpa)At Design
Temp (82 Deg)
Shell 2.14
Head 2.38
Flange (Minmum) 4.79
Nozzle(Minmimum) 1.98

Hence, Maximum Allowable Working Pressure of the vessel MAWP = 1.98 Mpa

SHEET of 95