Vous êtes sur la page 1sur 56

MASTERTEMP®125

HIGH PERFORMANCE HEATER


INSTALLATION AND USER’S GUIDE
FOR YOUR SAFETY - READ BEFORE OPERATING
,I\RXGRQRWIROORZWKHVHLQVWUXFWLRQVH[DFWO\D¿UHRUH[SORVLRQPD\UHVXOWFDXVLQJ
SURSHUW\GDPDJHSHUVRQDOLQMXU\RUORVVRIOLIH)RUDGGLWLRQDOIUHHFRSLHVRIWKLV
PDQXDOFDOO  
FOR YOUR SAFETY - This product must be installed and serviced by authorized personnel, qualified inpool/spa
heater installation. Improper installation and/or operation can create carbon monoxide gas and flue gases which can
cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Pentair
Aquatic Systems strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of this
appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty.

120/240 VAC NATURAL GAS/LP GAS


Models Natural Propane
125K BTU/HR (without cord) 461058 461060
125K BTU/HR (with cord) 461059 461061

OWNER:
Retain For
Future
Reference

,PSURSHULQVWDOODWLRQDGMXVWPHQWDOWHUDWLRQVHUYLFHRUPDLQWHQDQFHFDQFDXVH
SURSHUW\GDPDJHSHUVRQDOLQMXU\RUGHDWK,QVWDOODWLRQDQGVHUYLFHPXVWEHSHUIRUPHG
E\DTXDOL¿HGLQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXSSOLHU
WHAT TO DO IF YOU SMELL GAS
‡ 'RQRWWU\WROLJKWDQ\DSSOLDQFH
‡ 'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRWXVHDQ\SKRQHLQ\RXUEXLOGLQJ
FOR ‡ ,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU¶VSKRQH
YOUR  )ROORZWKHJDVVXSSOLHU¶VLQVWUXFWLRQV
‡ ,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKH¿UHGHSDUWPHQW
SAFETY
'2127VWRUHRUXVHJDVROLQHRURWKHUÀDPPDEOHYDSRUVDQGOLTXLGVLQWKHYLFLQLW\
RIWKLVRURWKHUDSSOLDQFHV

Pentair Water Pool and Spa, Inc.


1620 Hawkins Ave., Sanford, NC 27330 ɒ (800) 831-7133 or (919) 566-8000
10951 W. Los Angeles Ave., Moorpark, CA 93021 ɒ (800) 831-7133 or (805) 553-5000
2

Customer Service and Technical Support


If you have questions about ordering Pentair Aquatic Systems replacement parts, and pool
products, please call:
Phone: (800) 831-7133 - (8 AM to 4:30 PM Pacific Time and Eastern Time)

Fax: (800) 284-4151

Web sites: www.pentairpool.com - www.staritepool.com

P/N 475000 Rev. A

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
3
Contents
6HFWLRQ+HDWHU,GHQWL¿FDWLRQ,QIRUPDWLRQ......................................................................... 4
6HFWLRQ:DUQLQJDQG6DIHW\,QIRUPDWLRQ.......................................................................... 5
Important Notices ................................................................................................................................................................................. 5
Warranty Information ............................................................................................................................................................................ 5
Code Requirements.............................................................................................................................................................................. 6
Consumer Information and Safety Information ..................................................................................................................................... 6-9
General Specifications.......................................................................................................................................................................... 9
Section 3. Installation .............................................................................................................. 10
Heater Description ................................................................................................................................................................................ 10
Putting the Heater into Service ............................................................................................................................................................. 10
Specifications ....................................................................................................................................................................................... 11
Plumbing Connections.......................................................................................................................................................................... 12
Valves ................................................................................................................................................................................................... 12
Manual By-Pass ................................................................................................................................................................................... 12
Water Connections ............................................................................................................................................................................... 13
Below Pool Installation ......................................................................................................................................................................... 13
Gas Connections .................................................................................................................................................................................. 14
Sediment Traps ................................................................................................................................................................................... 14
Gas Pipe Sizing .................................................................................................................................................................................... 15
Testing Gas Pressure/Gas Pressure Requirements ............................................................................................................................. 15
Outdoor Installation (US and Canada) / Heater Clearances ................................................................................................................ 16
Outdoor Installation Venting Guidelines .............................................................................................................................................. 17
Indoor Venting — General Requirements (Category I and Category III requirements) ...................................................................... 17
Heater Clearances — General Requirements (Indoor Installation for US or Outdoor Shelter for Canada) ....................................... 18
Outside Vent Cover Removal ............................................................................................................................................................... 18
Combustion Air Supply ......................................................................................................................................................................... 18
Direct Air Intake Exhaust Duct using 3-inch PVC Pipe (Indoor Installation) / Corrosive Vapors and Possible Causes ........................ 19
Vent Installation (Indoor Installation for U.S. or Outdoor Shelter for Canada) ...................................................................................... 20
Vertical Venting - Negative Pressure ................................................................................................................................................... 20 - 22
Horizontal or Vertical Venting - Positive Pressure ............................................................................................................................... 23
Connecting Special Gas Venting .......................................................................................................................................................... 23 - 25
Outdoor Shelter Vent Installation .......................................................................................................................................................... 26
Garage or Utility Room Installation ....................................................................................................................................................... 26
Control Panel Indexing ......................................................................................................................................................................... 27
Final Installation Check ........................................................................................................................................................................ 27
Electrical Connections .......................................................................................................................................................................... 28
Fireman’s Switch Connection/Remote Control Connections ................................................................................................................ 29
MasterTemp® 125 Heater Wiring Diagram ........................................................................................................................................... 30
Electrical Schematic Ladder Diagram .................................................................................................................................................. 31
Section 4. Operation ................................................................................................................ 32
Basic System Operation ....................................................................................................................................................................... 32
HSI (Hot-Surface Ignition) Lighting/Operation ...................................................................................................................................... 32
Operating ............................................................................................................................................................................................. 33
To Turn Off Gas to Appliance ................................................................................................................................................................ 33
Safety Controls ..................................................................................................................................................................................... 34 - 36
Section 5. Troubleshooting .................................................................................................... 37
Initial Troubleshooting and Troubleshooting Chart ............................................................................................................................... 38
Heater Will Not Fire Troubleshooting .................................................................................................................................................... 39 - 42
LED Diagnostics ................................................................................................................................................................................... 43 - 44
Burner / Heat Exchanger Troubleshooting ........................................................................................................................................... 45
Section 6. Maintenance ........................................................................................................... 45
Care and Maintenance ......................................................................................................................................................................... 46
Pressure Relief Valve ........................................................................................................................................................................... 45
After Start-Up........................................................................................................................................................................................ 46
Spring, Fall and Winter Operation ........................................................................................................................................................ 46
Maintaining Pool Temperature .............................................................................................................................................................. 47
Energy Saving Tips............................................................................................................................................................................... 48
Chemical Balance................................................................................................................................................................................. 47 - 48
Replacement Parts ............................................................................................................................................................................... 49 - 53

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
4 Section 1. Heater Identification Information

Section 1: Heater Identification Information


7RLGHQWLI\WKHKHDWHUVHHUDWLQJSODWHRQWKHLQQHUIURQWSDQHORIWKHKHDWHU7KHUHDUHWZRGHVLJQDWRUVIRUHDFKKHDWHU
RQHLVWKH0RGHO1XPEHUDQGWKHRWKHULVWKH+HDWHU,GHQWL¿FDWLRQ1XPEHU +,1 
D +HDWHU,GHQWL¿FDWLRQ1XPEHU +,1
7KHIROORZLQJexampleVLPSOL¿HVWKHLGHQWL¿FDWLRQV\VWHP
  MT0DVWHU7HPSŠ125
  Model Size 125 ,QSXWUDWLQJ %WXKU ;
  Fuel Type  LP 3URSDQHJDVRU1$ 1DWXUDOJDV
  Construction  STD 6WDQGDUG0RGHO

HEATER IDENTIFICATION INFORMATION — (HIN)

H. I. N.
HEATER IDENTIFICATION NUMBER
ID DESIGNATOR FOR PENTAIR AQUATIC SYSTEMS MASTERTEMP® 125 HEATER

Example:
1 2 3 4
MT 125 NA STD

CONSTRUCTION = STD = STANDARD MODEL

NA = NATURAL GAS
FUEL TYPE =
LP = PROPANE GAS

MODEL SIZE = BTU INPUT in 1000 of BTU / HR

MT = MASTERTEMP

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 2. Warning and Safety Instructions 5

Section 2: Warning and Safety Instructions


IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS

MasterTemp® 125 High Performance Heater


&RQJUDWXODWLRQV RQ \RXU SXUFKDVH RI D 0DVWHU7HPS®  KLJK SHUIRUPDQFH KHDWLQJ V\VWHP 3URSHU LQVWDOODWLRQ DQG
VHUYLFHRI\RXUQHZKHDWLQJV\VWHPDQGFRUUHFWFKHPLFDOPDLQWHQDQFHRIWKHZDWHUZLOOHQVXUH\HDUVRIHQMR\PHQW7KH
0DVWHU7HPS®KHDWHULVDFRPSDFWOLJKWZHLJKWHI¿FLHQWLQGXFHGGUDIWJDV¿UHGKLJKSHUIRUPDQFHSRRODQGVSDKHDWHU
WKDWFDQEHGLUHFWO\FRQQHFWHGWRVFKHGXOH39&SLSH7KHKHDWHUDOVRFRPHVHTXLSSHGZLWKWKH3HQWDLUPXOWLIXQFWLRQ
WHPSHUDWXUHFRQWUROOHUZKLFKVKRZVDWDJODQFHWKHSURSHUIXQFWLRQLQJRIWKHKHDWHU$OO0DVWHU7HPS®KHDWHUVDUH
GHVLJQHGZLWKDGLUHFWLJQLWLRQGHYLFH+6, KRWVXUIDFHLJQLWLRQ ZKLFKHOLPLQDWHVWKHQHHGIRUDVWDQGLQJSLORW7KH
0DVWHU7HPS®KHDWHUUHTXLUHVDQH[WHUQDOSRZHUVRXUFH 9$&+] WRRSHUDWH
63(&,$/,16758&7,216722:1(55HWDLQWKLVPDQXDOIRUIXWXUHUHIHUHQFH7KLVLQVWUXFWLRQPDQXDOSURYLGHV
RSHUDWLQJ LQVWUXFWLRQV LQVWDOODWLRQ DQG VHUYLFH LQIRUPDWLRQ  IRU WKH 0DVWHU7HPS®  KLJK SHUIRUPDQFH KHDWHU7KH
LQIRUPDWLRQLQWKLVPDQXDODSSOLHVWRDOO0DVWHU7HPS®KHDWHUPRGHOV5($'$1'5(9,(:7+,60$18$/
&203/(7(/< LW LV YHU\ LPSRUWDQW WKDW WKH RZQHULQVWDOOHU UHDG DQG XQGHUVWDQG WKH VHFWLRQ FRYHULQJ LQVWDOODWLRQ
LQVWUXFWLRQVDQGUHFRJQL]HWKHORFDODQGVWDWHFRGHVEHIRUHLQVWDOOLQJWKH0DVWHU7HPS®KHDWHU,WVXVHZLOOUHGXFH
VHUYLFHFDOOVDQGFKDQFHRILQMXU\DQGZLOOOHQJWKHQSURGXFWOLIH+LVWRU\DQGH[SHULHQFHKDVVKRZQWKDWPRVWKHDWHU
GDPDJHLVFDXVHGE\LPSURSHULQVWDOODWLRQSUDFWLFHV

IMPORTANT NOTICES
)RUWKHLQVWDOOHUDQGRSHUDWRURIWKH0DVWHU7HPS®SRRODQGVSDKHDWHU7KHPDQXIDFWXUHU¶VZDUUDQW\PD\EHYRLG
LIIRUDQ\UHDVRQWKHKHDWHULVLPSURSHUO\LQVWDOOHGDQGRURSHUDWHG%HVXUHWRIROORZWKHLQVWUXFWLRQVVHWIRUWKLQWKLV
PDQXDO,I\RXQHHGDQ\PRUHLQIRUPDWLRQRULI\RXKDYHDQ\TXHVWLRQVUHJDUGLQJWRWKLVSRROKHDWHUSOHDVHFRQWDFW
3HQWDLU$TXDWLF6\VWHPVDW  

WARRANTY INFORMATION
7KH0DVWHU7HPSŠSRROKHDWHULVVROGZLWKDOLPLWHGIDFWRU\ZDUUDQW\ 6SHFL¿FGHWDLOVDUHGHVFULEHGRQWKHZDU-
UDQW\UHJLVWUDWLRQFDUGZKLFKLVLQFOXGHGZLWKWKHSURGXFW5HWXUQWKHZDUUDQW\UHJLVWUDWLRQFDUGDIWHU¿OOLQJLQWKH
VHULDOQXPEHUIURPWKHUDWLQJSODWHLQVLGHWKHKHDWHU

3HQWDLU$TXDWLF6\VWHPVKLJKVWDQGDUGVRIH[FHOOHQFHLQFOXGHDSROLF\RIFRQWLQXRXVSURGXFWLPSURYHPHQWUHVXOWLQJ
LQ\RXUVWDWHRIWKHDUWKHDWHU:HUHVHUYHWKHULJKWWRPDNHLPSURYHPHQWVZKLFKFKDQJHWKHVSHFL¿FDWLRQVRIWKH
KHDWHUZLWKRXWLQFXUULQJDQREOLJDWLRQWRXSGDWHWKHFXUUHQWKHDWHUHTXLSPHQW

7KHVHKHDWHUVDUHGHVLJQHGIRUWKHKHDWLQJRIFKORULQHEURPLQHRUVDOWV\VWHPVZLPPLQJSRROVDQGVSDVRULQ
QRQVWDWLRQDU\LQVWDOODWLRQVDQGVKRXOGQHYHUEHHPSOR\HGIRUXVHDVVSDFHKHDWLQJERLOHUVRUJHQHUDOSXUSRVH
ZDWHUKHDWHUV7KHPDQXIDFWXUHU¶VZDUUDQW\PD\EHYRLGLIIRUDQ\UHDVRQWKHKHDWHULVLPSURSHUO\LQVWDOOHG
DQGRURSHUDWHG%HVXUHWRIROORZWKHLQVWUXFWLRQVVHWIRUWKLQWKLVPDQXDO

CAUTION
OPERATING THIS HEATER CONTINUOUSLY AT WATER TEMPERATURE BELOW 68° F. WILL CAUSE HARMFUL
CONDENSATION AND WILL DAMAGE THE HEATER AND VOID THE WARRANTY. Do not use the heater to protect pools
or spas from freezing if the final maintenance temperature desired is below 68° F., as this will cause condensation
related problems.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
6 Section 2. Warning and Safety Instructions

CODE REQUIREMENTS
,QVWDOODWLRQPXVWEHLQDFFRUGDQFHZLWKDOOORFDOFRGHVDQGRUWKHODWHVWHGLWLRQRIWKH1DWLRQDO)XHO*DV&RGH
$16,=DQGWKHODWHVWHGLWLRQRIWKH1DWLRQDO(OHFWULFDO&RGH1)3$ 86 
,QVWDOODWLRQLQ&DQDGDPXVWEHLQDFFRUGDQFHZLWKWKHODWHVW&$1&*$%RUDQG&6$&&DQDGLDQ
(OHFWULF&RGHSDUW
7KHKHDWHUZKHQLQVWDOOHGPXVWEHHOHFWULFDOO\JURXQGHGDQGERQGHGLQDFFRUGDQFHZLWKORFDOFRGHVRULQDEVHQFH
RIORFDOFRGHVZLWKWKH1DWLRQDO(OHFWULFDO&RGH$16,1)3$ 86 RULQ&DQDGDLQDFFRUGDQFHZLWKWKH&DQDGLDQ
(OHFWULF&RGHSDUWDVDSSOLFDEOH

DANGER
CARBON MONOXIDE GAS IS DEADLY – Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous,
poisonous gas you cannot see or smell.

CONSUMER INFORMATION AND SAFETY

WARNING
The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous.
See below for water temperature guidelines before setting temperature.

 6SDRUKRWWXEZDWHUWHPSHUDWXUHVVKRXOGQHYHUH[FHHGƒ) ƒ& $WHPSHUDWXUHRIƒ) ƒ& LVFRQVLGHUHG


VDIHIRUDKHDOWK\DGXOW6SHFLDOFDXWLRQLVVXJJHVWHGIRU\RXQJFKLOGUHQ
 'ULQNLQJ RI DOFRKROLF EHYHUDJHV EHIRUH RU GXULQJ VSD RU KRW WXE XVH FDQ FDXVH GURZVLQHVV ZKLFK FRXOG OHDG WR
XQFRQVFLRXVQHVVDQGVXEVHTXHQWO\UHVXOWLQGURZQLQJ
 3UHJQDQWZRPHQEHZDUH6RDNLQJLQZDWHUDERYHƒ) ƒ& FDQFDXVHIHWDOGDPDJHGXULQJWKH¿UVWWKUHH
PRQWKVRISUHJQDQF\ UHVXOWLQJLQWKHELUWKRIDEUDLQGDPDJHGRUGHIRUPHGFKLOG 3UHJQDQWZRPHQVKRXOGVWLFN
WRWKHƒ) ƒ& PD[LPXPUXOH
 %HIRUHHQWHULQJWKHVSDRUKRWWXEWKHXVHUVKRXOGFKHFNWKHZDWHUWHPSHUDWXUHZLWKDQDFFXUDWHWKHUPRPHWHU6SD
RUKRWWXEWKHUPRVWDWVPD\HUULQUHJXODWLQJZDWHUWHPSHUDWXUHVE\DVPXFKDVƒ) ƒ& 
 3HUVRQVZLWKDPHGLFDOKLVWRU\RIKHDUWGLVHDVHFLUFXODWRU\SUREOHPVGLDEHWHVRUEORRGSUHVVXUHSUREOHPVVKRXOG
REWDLQWKHLUSK\VLFLDQ¶VDGYLFHEHIRUHXVLQJVSDVRUKRWWXEV
 3HUVRQVWDNLQJPHGLFDWLRQZKLFKLQGXFHGURZVLQHVVVXFKDVWUDQTXLOL]HUVDQWLKLVWDPLQHVRUDQWLFRDJXODQWVVKRXOG
QRWXVHVSDVRUKRWWXEV

WARNING
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the heater.
Do not use this heater if any part has been under water. Immediately call a qualified service technician to
inspect the heater and to replace any part of control system and gas control which has been under water.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 2. Warning and Safety Instructions 7

SAFETY INFORMATION
The MasterTemp® 125 Heater is designed and manufactured to provide many years of safe and reliable service when installed,
operated and maintained according to the information in this manual. Throughout this manual, safety warnings and cautions
are identified by the “ “ symbol. Be sure to read and comply with all of the warnings and cautions.

DANGER — CARBON MONOXIDE GAS IS DEADLY


READ OWNERS MANUAL COMPLETELY BEFORE OPERATING
THIS PRODUCT MUST BE INSTALLED AND SERVICED BY A PROFESSIONAL SERVICE
TECHNICIAN, QUALIFIED IN POOL HEATER INSTALLATION. Some jurisdictions require that
installers be licensed. Check with your local building authority about contractor licensing requirements.
Improper installation and/or operation could create carbon monoxide gas and flue gases which could
cause serious injury or death. Improper installation and/or operation will void the warranty.
Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous, poisonous gas
you cannot see or smell. Symptoms of carbon monoxide exposure or poisoning include dizziness,
headache, nausea, weakness, sleepiness, muscular twitching, vomiting and inability to think clearly.
IF YOU EXPERIENCE ANY OF THE ABOVE SYMPTOMS, IMMEDIATELY TURN OFF THE POOL
HEATER, LEAVE THE VICINITY OF THE POOL OR SPA AND GET INTO FRESH AIR IMMEDIATELY.
THE POOL HEATER MUST BE THOROUGHLY TESTED BY A GAS PROFESSIONAL BEFORE
RESUMING OPERATION.
EXCESSIVE CARBON MONOXIDE EXPOSURE CAN CAUSE BRAIN DAMAGE OR DEATH.
sNEVER use this pool heater indoors without specified ventilation system (and properly installed
vent pipe).
sNEVER use this pool heater in the home or in partly enclosed areas (such as garages), unless
the specified ventilation system is used. If used outdoors, install far from open windows, doors,
vents and other openings.
s Pentair strongly recommends that all vents, pipes and exhaust systems be initially and
periodically tested for proper operation. This testing can be accomplished by using a hand-held
carbon monoxide meter and/or by consulting with a gas professional.
s Pool heaters must be used in conjunction with carbon monoxide detectors installed near the
pool heater. The carbon monoxide detectors must be periodically inspected for proper operation so

WARNING — FOR YOUR SAFETY


This product must be installed and serviced by a professional service technician, qualified in pool
heater installation. Some jurisdictions require that installers be licensed. Check with your local building
authority about contractor licensing requirements. Improper installation and/or operation could create
carbon monoxide gas and flue gases which could cause serious injury or death. Improper installation
and/or operation will void the warranty.
WARNING — This heater is equipped with an unconventional gas control valve that is factory set with
a manifold pressure of -.2 inches wc. Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of life. Installation or service must
be performed by a qualified installer, service agency or the gas supplier. If this control is replaced, it
must be replaced with an identical control.
Do not attempt to adjust the gas flow by adjusting the regulator setting.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
8 Section 2. Warning and Safety Instructions

SAFETY INFORMATION, (cont’d.)

WARNING — Risk of fire or explosion from incorrect fuel use or faulty fuel conversion. Do not try to run a
heater set up for natural gas on propane gas or vice versa. Only qualified service technicians should
attempt to convert heater from one fuel to the other. Do not attempt to alter the rated input or type of
gas by changing the orifice. If it is necessary to convert to a different type of gas, consult your Pentair
dealer. Serious malfunction of the burner can occur which may result in loss of life. Any additions,
changes, or conversions required in order for the appliance to satisfactorily meet the application needs
must be made by a Pentair dealer or other qualified agency using factory specified and approved
parts. The heater is available for use with natural gas or LP (propane) gas only. It is not designed to
operate with any other fuels. Refer to the nameplate for the type of gas the heater is equipped to use.
s 5SEHEATERONLYWITHTHEFUELFORWHICHITISDESIGNED
s )F A FUEL CONVERSION IS NECESSARY REFER THIS WORK TO A QUALIlED SERVICE TECHNICIAN OR GAS SUPPLIER
before putting the heater into operation.

WARNING — Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes,
paints, or other volatile flammable liquids near heater or in the same room with heater.

WARNING — Risk of explosion if unit is installed near propane gas storage. Propane (LP) gas is heavier than
air. Consult local codes and fire protection authorities about specific installation requirements and
restrictions. Locate the heater away from propane gas storage and filling equipment as specified by
the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2 (latest
edition) or ANSI/NFPA 58 (latest edition).

WARNING — Risk of fire, carbon monoxide poisoning, or asphyxiation if exhaust venting system leaks. Only
qualified service technicians should attempt to service the heater, as leakage of exhaust products or
flammable gas may result from incorrect servicing.

WARNING — Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly
when installing heater. Do not use a draft hood with this heater, as the exhaust is under pressure
from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the
heater. The heater is supplied with an integral venting system for outdoor installation. A vent conversion
kit (See Page 23 for Part Numbers for Conversion Kits) is available for installations in enclosures
Canada) or indoors (U.S.). Use the specified venting, and only the specified venting, when heater is
installed in an enclosure or indoors. In Canada, this pool heater can only be installed outdoors or in
an enclosure that is not normally occupied and has no openings directly into occupied areas. See
Page 18 for enclosure venting requirements.

CAUTION — Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Wiring errors can also destroy the control board.
s #ONNECTHEATERTO120 or 240 Volt, 60 Hz., Single Phase power only.
s 6ERIFYPROPEROPERATIONAFTERSERVICING
s $ONOTALLOWCHILDRENTOPLAYONORAROUNDHEATERORASSOCIATEDEQUIPMENT
s .EVERALLOWCHILDRENTOUSETHEPOOLORSPAWITHOUTADULTSUPERVISION
s 2EAD AND FOLLOW OTHER SAFETY INFORMATION CONTAINED IN THIS MANUAL PRIOR TO OPERATING THIS POOL
heater.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 2. Warning and Safety Instructions 9

CONSUMER INFORMATION AND SAFETY

WARNING
The U.S. Consumer Product Safety Commission warns that carbon monoxide is an “invisible killer”. Carbon monoxide
is a colorless and odorless gas.

 &DUERQPRQR[LGHLVSURGXFHGE\EXUQLQJIXHOLQFOXGLQJQDWXUDOJDVDQGSURSDQH
 3URSHULQVWDOODWLRQRSHUDWLRQDQGPDLQWHQDQFHRIIXHOEXUQLQJDSSOLDQFHVLQWKHKRPHLVWKHPRVWLPSRUWDQW
IDFWRULQUHGXFLQJFDUERQPRQR[LGHSRLVRQLQJ
 %HVXUHWKDWIXHOEXUQLQJDSSOLDQFHVVXFKDVKHDWHUVDUHLQVWDOOHGE\SURIHVVLRQDOVDFFRUGLQJWRPDQXIDFWXUHU¶V
LQVWUXFWLRQVDQGFRGHV
 $OZD\VIROORZWKHPDQXIDFWXUHU¶VGLUHFWLRQVIRUVDIHRSHUDWLRQ
 +DYHWKHKHDWLQJV\VWHP LQFOXGLQJYHQWV LQVSHFWHGDQGVHUYLFHGDQQXDOO\E\DWUDLQHGVHUYLFHWHFKQLFLDQ
 ([DPLQHYHQWVUHJXODUO\IRULPSURSHUFRQQHFWLRQVYLVLEOHFUDFNVUXVWRUVWDLQV
 ,QVWDOOEDWWHU\RSHUDWHGFDUERQPRQR[LGHDODUPV7KHDODUPVVKRXOGEHFHUWL¿HGWRWKHUHTXLUHPHQWVRIWKH
PRVWUHFHQW8/,$6&6$DQG,$302VWDQGDUGIRUFDUERQPRQR[LGHDODUPV7HVWFDUERQPRQR[LGHDODUPV
UHJXODUO\DQGUHSODFHGHDGEDWWHULHV

GENERAL SPECIFICATIONS

NOTICE:
s #OMBUSTIONAIRCONTAMINATEDBYCORROSIVECHEMICALFUMESCANDAMAGETHEHEATERANDWILLVOIDTHEWARRANTY
s 4HE#OMBINATION'AS#ONTROL6ALVEONTHISHEATERDIFFERSFROMMOSTAPPLIANCEGASCONTROLS)FITMUSTBEREPLACED
for safety reasons replace it only with an identical gas control.
s 4HEACCESSDOORPANELSMUSTBEINPLACETOPROVIDEPROPERVENTILATION$ONOTOPERATETHEHEATERFORMORETHANlVE
minutes with the access door panels removed.
s 4HISHEATERISDESIGNCERTIlEDBY#3!)NTERNATIONALASCOMPLYINGWITHTHE3TANDARDFOR'AS&IRED0OOL(EATERS
ANSI Z21.56/CSA 4.7, and is intended for use in heating fresh water swimming pools or spas.
s 4HEHEATERISDESIGNEDFORTHEHEATINGOFCHLORINE BROMINEORSALTSYSTEMSWIMMINGPOOLSANDSPAS)TSHOULDNOT be
used as a space heating boiler, or general purpose water heater.
s 4HEHEATERISDESIGNCERTIlEDBY#3!)NTERNATIONALFORINSTALLATIONONCOMBUSTIBLEmOORING3PECIlEDMINIMUM
clearances must be maintained to combustible surfaces (see “Heater Clearances”, page 18).
s 4HEHEATERSHOULDBELOCATEDINANAREAWHERELEAKAGEOFTHEHEATERORCONNECTIONSWILLNOTRESULTINDAMAGETOTHE
area adjacent to the heater or to the structure. When such locations cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed under the heater. The pan must not restrict air flow.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
10 Section 3. Installation Instructions

Section 3: Installation Instructions


HEATER DESCRIPTION

Gas


Exhaust
)LJXUH  LV D GLDJUDP RI WKH KHDWHU VKRZLQJ KRZ LW RSHUDWHV Air
Blower
3UHFLVHO\PDWFKHGRUL¿FHSODWHVPHWHUWKHDLUDQGJDVLQWRWKHPL[HU
7KHEORZHUGUDZVWKHDLUDQGJDVWKURXJKWKHPL[HUDQGIRUFHVLWLQWR Mixer
WKHEXUQHU¶VÀDPHKROGHU$VHDOHGKHDWH[FKDQJHUVXUURXQGVWKHÀDPH Inlet
KROGHUGLVFKDUJLQJH[KDXVWJDVHVRXWWKHÀXH (Cold
Water)

7ZRLQFK39&ZDWHUSLSLQJFRQQHFWVGLUHFWO\WRWKHPDQLIROGKHDGHURQ
WKHKHDWH[FKDQJHUXVLQJ´39&VOLSXQLRQVSURYLGHGZLWKWKHKHDWHU
7KHRXWHUPDQLIROGUHPDLQVFRROQRKHDWVLQNVDUHUHTXLUHG$WKHUPDO
UHJXODWRUDQGDQLQWHUQDOE\SDVVUHJXODWHWKHZDWHUÀRZWKURXJKWKHKHDW
H[FKDQJHUWRPDLQWDLQWKHFRUUHFWRXWOHWWHPSHUDWXUH7KHKHDWHURSHUDWRU
Outlet
FRQWUROSDQHOERDUGDVVHPEO\LVORFDWHGRQWRSRIWKHKHDWHU (Mixed
Water)
Burner Heating Coils

SEQUENCE OF OPERATION
Figure 1.

$QHOHFWURQLFWHPSHUDWXUHVHQVLQJWKHUPLVWRULQWKHPDQLIROGDGDSWHULQOHWFRQWUROVWKHKHDWHURSHUDWLRQ:KHQWKHLQOHW
ZDWHUWHPSHUDWXUHGURSVEHORZWKHWHPSHUDWXUHVHWRQWKHRSHUDWLQJFRQWUROWKHEXUQHUFRQWUROOHUVXSSOLHVSRZHUWRWKH
FRPEXVWLRQDLUEORZHUWKURXJKDVHULHVRIVDIHW\LQWHUORFNV7KHLQWHUORFNVFRQVLVWRI
‡WKHSUHVVXUHVZLWFK PS ZKLFKVHQVHVWKDWWKHSXPSLVUXQQLQJ
‡WKHKLJKOLPLWVZLWFK HLS ZKLFKRSHQVLIWKHKHDWH[FKDQJHURXWOHWWHPSHUDWXUHJRHVDERYHƒ) ƒ& DQG
‡WKHDLUÀRZVZLWFK $)6 ZKLFKVHQVHVWKHSUHVVXUHGURSDFURVVWKHDLUPHWHULQJRUL¿FH
‡WKH DXWRPDWLF JDV VKXWRII $*6  VZLWFK ZKLFK RSHQV LI WKH KHDW H[FKDQJHU RXWOHW WHPSHUDWXUH JRHV DERYH
ƒ) ƒ& 
‡WKHVWDFNÀXHVHQVRU 6)6 ZKLFKVKXWVGRZQWKHKHDWHULIWKHÀXHJDVWHPSHUDWXUHUHDFKHVƒ) ƒ& 
7KHDLUÀRZVZLWFK $)6 VHQVHVWKHSUHVVXUHGURSDFURVVWKHDLUPHWHULQJRUL¿FH$VVRRQDVWKHUHLVVXI¿FLHQWDLUÀRZ
WKH$)6FORVHVFORVLQJWKHFLUFXLWWRWKHKRWVXUIDFHLJQLWHU HSI ZKLFKLJQLWHVWKHIXHOPL[WXUH2QDFDOOIRUKHDWWKH
EORZHUDQG+6,DUHHQHUJL]HG,QDERXWVHFRQGVWKHJDVYDOYHRSHQVDQGLJQLWLRQRFFXUV7KH+6,WKHQVZLWFKHVWRD
VHQVLQJPRGHDQGPRQLWRUVWKHÀDPH
7KH KHDWHU LV HTXLSSHG ZLWK D GLJLWDO RSHUDWLQJ FRQWURO WKDW HQDEOHV WKH XVHU WR SUHVHW WKH GHVLUHG SRRO DQG VSD ZDWHU
WHPSHUDWXUHV7KHFRQWUROHQDEOHVWKHXVHUWRVHOHFWEHWZHHQSRRODQGVSDKHDWLQJDQGIHDWXUHVDGLJLWDOGLVSOD\WKDWLQGLFDWHV
WKHZDWHUWHPSHUDWXUH

PUTTING THE HEATER INTO SERVICE



,IWKHKHDWHULVLQVWDOOHGEHORZWKHOHYHORIWKHSRRORUPRUHWKDQWZRIHHWDERYHSRROOHYHOWKHSUHVVXUHVZLWFKVHWWLQJ
VKRXOGEHDGMXVWHG6HH:$7(535(6685(6:,7&+LQWKH6$)(7<&21752/66HFWLRQ
%HIRUHSXWWLQJWKHKHDWHULQWRVHUYLFHIRUWKH¿UVWWLPHIROORZWKHLQVWUXFWLRQVXQGHU³%()25(67$5783´ SDJH LQWKH
IURQWRIWKLVPDQXDO&KHFNIRUSURSHURSHUDWLRQRIWKHKHDWHUE\IROORZLQJWKHVWHSVXQGHU³23(5$7,21,16758&7,216´
'DPDJHWRHTXLSPHQWFDXVHGE\LPSURSHULQVWDOODWLRQRUUHSDLUZLOOYRLGWKHZDUUDQW\

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 11

SPECIFICATIONS
7KHVHLQVWDOODWLRQLQVWUXFWLRQVDUHGHVLJQHGIRUXVHE\TXDOL¿HGSHUVRQQHORQO\WUDLQHGHVSHFLDOO\IRULQVWDOODWLRQRIWKLV
W\SHRIKHDWLQJHTXLSPHQWDQGUHODWHGFRPSRQHQWV6RPHVWDWHVUHTXLUHLQVWDOODWLRQDQGUHSDLUE\OLFHQVHGSHUVRQQHO
,IWKLVDSSOLHVLQ\RXUVWDWHEHVXUH\RXUFRQWUDFWRUEHDUVWKHDSSURSULDWHOLFHQVH6HH)LJXUHIRU2XWGRRUDQG,QGRRU
,QVWDOODWLRQV

DIMENSIONS IN INCHES 20.85"


52.95cm

ELECTRICAL
CONDUIT PORT

29.43" 21"
74.76 53 cm
17.5"
44.5cm
10.87"
28.cm

FRONT VIEW TOP VIEW

23"
58.4cm

10.87"
27.6cm 5.5"
14cm

EXHAUST SIDE VIEW PLUMBING SIDE VIEW

Figure 2.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
12 Section 3. Installation Instructions

PLUMBING CONNECTIONS
 Figure 3.
7KH 0DVWHU7HPS®  KHDWHU KDV WKH XQLTXH FDSDELOLW\ RI
GLUHFW VFKHGXOH  39& SOXPELQJ FRQQHFWLRQV $ VHW RI
EXONKHDG ¿WWLQJV LV LQFOXGHG ZLWK WKH 0DVWHU7HPSŠ 
KHDWHU WR LQVXUH FRQIRUPLW\ ZLWK 3HQWDLU¶V UHFRPPHQGHG
39&SOXPELQJSURFHGXUH2WKHUSOXPELQJFRQQHFWLRQVFDQ
EHXVHG6HH)LJXUHIRUSOXPELQJFRQQHFWLRQV

CAUTION HEATER
FROM
FILTER
MANUAL
TO
POOL
FILTER
PUMP
BY-PASS

Before operating the heater on a new installation, turn on GATE


VALVE
the circulation pump and bleed all the air from the filter
using the air relief valve on top of the filter. Water should FROM
POOL

flow freely through the heater. Do not operate the heater


unless water in the pool/spa is at the proper level. If a
manual by-pass is installed, temporarily close it to insure 3-Way
that all air is purged from the heater. Valve Chlorinator

WATER CONNECTIONS Check Valve


7KH KHDWHU UHTXLUHV SURSHU ZDWHU ÀRZ DQG SUHVVXUH IRU LWV
RSHUDWLRQ6HH)LJXUHIRUWKHUHFRPPHQGHGLQVWDOODWLRQ7KH Heater
¿OWHUSXPSGLVFKDUJHVWRWKH¿OWHUWKH¿OWHUGLVFKDUJHVWRWKH Main
KHDWHUDQGWKHKHDWHUGLVFKDUJHVGLUHFWO\WRWKHSRRORUVSD Drain Filter

$PDQXDOE\SDVVYDOYHVKRXOGEHLQVWDOOHGDFURVVWKHKHDWHU Pool Spa


ZKHQ WKH SXPS ÀRZ H[FHHGV  *30  /30   6HH
³:$7(5)/2:5$7(´7DEOHRQSDJHIRUVHWWLQJRI Pump
WKHPDQXDOE\SDVVYDOYH
0DNHVXUHWKDWWKHRXWOHWSOXPELQJIURPWKHKHDWHUFRQWDLQV
QRVKXWRIIYDOYHVRURWKHUÀRZUHVWULFWLRQVWKDWFRXOGSUHYHQW
ÀRZWKURXJKWKHKHDWHU H[FHSWIRUSRROLQVWDOODWLRQVDVQRWHG From Pool 3-Way 3-Way
EHORZRUZLQWHUL]LQJYDOYHVZKHUHQHHGHG 7RVZLWFKÀRZ Valve Valve
EHWZHHQWKHSRRODQGVSDXVHDGLYHUWHUYDOYH'RQRWXVH
Figure 4.
DQ\YDOYHWKDWFDQVKXWRIIWKHÀRZ
,QVWDOOWKHFKHPLFDOIHHGHUGRZQVWUHDPRIWKHKHDWHU,QVWDOODFKHPLFDOUHVLVWDQWRQHZD\FKHFNYDOYHEHWZHHQWKH
KHDWHUDQGWKHFKHPLFDOIHHGHUWRSUHYHQWEDFNVLSKRQLQJWKURXJKWKHKHDWHUZKHQWKHSXPSLVRII
NOTICE:,IWKHKHDWHULVSOXPEHGLQEDFNZDUGVLWZLOOF\FOHFRQWLQXRXVO\0DNHVXUHSLSLQJIURP¿OWHULVQRWUHYHUVHG
ZKHQLQVWDOOLQJKHDWHU
&RQQHFWWKHKHDWHUGLUHFWO\WR´39&SLSHXVLQJWKHLQWHJUDOXQLRQVSURYLGHG+HDWVLQNVDUHQRWUHTXLUHG7KHORZ
WKHUPDOPDVVRIWKHKHDWHUZLOOSUHYHQWRYHUKHDWLQJRIWKHSLSLQJFRQQHFWHGWRWKHSXPSHYHQLIWKHKHDWHUVKXWVGRZQ
XQH[SHFWHGO\,I\RXDUHXVLQJDÀH[LEOHFRUUXJDWHGKRVHIRUDERYHJURXQGV\VWHPVXVHRQO\3HQWDLUDSSURYHGÀH[LEOH
KRVHNLWV31 IW DQG31 IW 
2FFDVLRQDOO\DWZRVSHHGSXPSZLOOQRWGHYHORSHQRXJKSUHVVXUHRQWKHORZVSHHGWRRSHUDWHWKHKHDWHU,QWKLVFDVHUXQ
WKHSXPSDWKLJKVSHHGRQO\WRRSHUDWHWKHKHDWHU,IWKLVGRHVQRWVROYHWKHSUREOHPGRQRWWU\WRUXQWKHKHDWHU,QVWHDG
FRUUHFWWKHLQVWDOODWLRQ
'RQRWRSHUDWHWKHKHDWHUZKLOHDQDXWRPDWLFSRROFOHDQHULVDOVRRSHUDWLQJ,IWKHFLUFXODWLRQSXPSVXFWLRQLVSOXJJHG
IRUH[DPSOHE\OHDYHV WKHUHPD\QRWEHDGHTXDWHÀRZWRWKHKHDWHU'RQRWUHO\RQWKHSUHVVXUHVZLWFKLQWKLVFDVH

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 13

VALVES

:KHQDQ\HTXLSPHQWLVORFDWHGEHORZWKHVXUIDFHRIWKHSRRORUVSDYDOYHVVKRXOGEHSODFHGLQWKHFLUFXODWLRQSLSLQJ
V\VWHPWRLVRODWHWKHHTXLSPHQWIURPWKHSRRORUVSD&KHFNYDOYHVDUHUHFRPPHQGHGWRSUHYHQWEDFNVLSKRQLQJ%DFN
VLSKRQLQJLVPRVWOLNHO\WRRFFXUZKHQWKHSXPSVWRSVFUHDWLQJDSUHVVXUHVXFWLRQGLIIHUHQWLDO'R127VDQLWL]HWKH
SRROE\SXWWLQJFKORULQHWDEOHWVRUVWLFNVLQWRWKHVNLPPHU V :KHQWKHSXPSLVRIIWKLVZLOOFDXVHDKLJKFRQFHQWUDWLRQ
RIFKORULQHWRHQWHUWKHKHDWHUZKLFKFRXOGFDXVHFRUURVLRQGDPDJHWRWKHKHDWH[FKDQJHU

CAUTION
Exercise care when installing chemical feeders so as to not allow back siphoning of chemical into the heater, filters or
pump. When chemical feeders are installed in the circulation of the piping system, make sure the feeder outlet line is
down stream of the heater, and is equipped with a positive seal noncorrosive “Check Valve”, (P/N R172288), between
the feeder and heater.

MANUAL BY-PASS

:KHUHWKHZDWHUÀRZUDWHH[FHHGVWKHPD[LPXP*30 /30 
DPDQXDOE\SDVVVKRXOGEHLQVWDOOHGDQGDGMXVWHG$IWHULQVWDOOLQJWKH
YDOYHDGMXVWWKHYDOYHWREULQJWKHÀRZUDWHZLWKLQWKHDFFHSWDEOH
UDQJH 7KHQ UHPRYH WKH YDOYH KDQGOH RU ORFN LW LQ SODFH WR DYRLG
WDPSHULQJ6HH)LJXUH
Model Min. (GPM) (LPM) Max. (GPM) (LPM) *
Warm water out
125 20 (76) 70 (265)

* Do not exceed the maximum recommended flow


rate for the connecting piping.
Cool water in
Table 1.

See page 34 for Pressure Relief Valve Installations. 1. Set Manual By-Pass Valve.
2. Remove Handle.

BELOW POOL INSTALLATION INLET FROM HEATER

OUTLET TO POOL

,IWKHKHDWHULVEHORZZDWHUOHYHOWKHSUHVVXUHVZLWFKPXVWEHDG
MXVWHG7KLVDGMXVWPHQWPXVWEHGRQHE\DTXDOL¿HGVHUYLFHWHFKQL Figure 5.
FLDQ6HHIROORZLQJ&$87,21EHIRUHLQVWDOODWLRQ

CAUTION
BELOW OR ABOVE POOL INSTALLATION
The water pressure switch is set in the factory at 3.00 PSI (± 0.75 PSI). This setting is for a heater installed at pool level.
If the heater is to be installed more than 1’ above or below, the water pressure switch must be adjusted by a qualified
service technician. See page 34, Figure 29.

FLOW SWITCH
If the heater is installed more than 5’ above the pool or more than 4’ below the pool level, you will be beyond the limits
of the pressure switch and a flow switch must be installed. Locate and install the flow switch externally on the outlet
piping from the heater, as close as possible to the heater. Connect the flow switch wires in place of the water pressure
switch wires.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
14 Section 3. Installation Instructions

GAS CONNECTIONS
GAS LINE INSTALLATIONS
%HIRUHLQVWDOOLQJWKHJDVOLQHEHVXUHWRFKHFNZKLFKJDVWKHKHDWHUKDVEHHQGHVLJQHGWREXUQ7KLVLVLPSRUWDQWEHFDXVH
GLIIHUHQWW\SHVRIJDVUHTXLUHGLIIHUHQWJDVSLSHVL]HV7KHUDWLQJSODWHRQWKHKHDWHUZLOOLQGLFDWHZKLFKJDVWKHKHDWHULV
GHVLJQHGWREXUQ7DEOHVKRZQRQSDJHVKRZZKLFKVL]HSLSHLVUHTXLUHGIRUWKHGLVWDQFHIURPWKHJDVPHWHUWRWKH
KHDWHU7KHWDEOHLVIRUQDWXUDOJDVDWDVSHFL¿FJUDYLW\RIDQGSURSDQHDWDVSHFL¿FJUDYLW\RI
:KHQVL]LQJJDVOLQHVFDOFXODWHWKUHH  DGGLWLRQDOIHHWRIVWUDLJKWSLSHIRUHYHU\HOERZXVHG:KHQLQVWDOOLQJWKHJDV
OLQHDYRLGJHWWLQJGLUWJUHDVHRURWKHUIRUHLJQPDWHULDOLQWKHSLSHDVWKLVPD\FDXVHGDPDJHWRWKHJDVYDOYHZKLFK
PD\UHVXOWLQKHDWHUIDLOXUH
The gas meter should be checked to make sure that it will supply enough gas to the heater and any other appliances that
may be used on the same meter. The gas line from the meter will usually be of a larger size than the gas valve supplied
with the heater. Therefore a reduction of the connecting gas pipe will be necessary. Make this reduction as close to the
heater as possible.
7KHKHDWHUUHTXLUHVDJDVVXSSO\RIQRWOHVVWKDQ´ FP ZFDQGQRWPRUHWKDQ´ FP ZF*DVVXSSO\
SUHVVXUHVRXWVLGHRIWKLVUDQJHPD\UHVXOWLQLPSURSHUEXUQHURSHUDWLRQ$PLQLPXPÀRZLQJRUG\QDPLFLQOHWSUHVVXUH
ZKLOHWKHKHDWHULVUXQQLQJ RI´ FP ZFLVUHTXLUHGWRPDLQWDLQLQSXWUDWLQJZLWKQRPRUHWKDQD´SUHVVXUH
GURSEHWZHHQVWDWLFDQGG\QDPLF7KHJDVVXSSO\PXVWEHLQVWDOOHGLQDFFRUGDQFHZLWKWKHNational Fuel Gas Code,
ANSIZ223.1RUVWDQGDUGCSA B149.1Natural Gas and Propane Installation CodesDVDSSOLFDEOHDQGDOODSSOLFDEOHORFDO
FRGHV,QVWDOODPDQXDOVKXWRIIYDOYHDQGDVHGLPHQWWUDSDQGXQLRQORFDWHGRXWVLGHWKHKHDWHUSDQHOVVHH)LJXUH'R
QRWXVHDUHVWULFWLYHJDVFRFN7KHIROORZLQJPLQLPXPJDVSLSHVL]HVDUHUHFRPPHQGHGIRUQDWXUDOJDVVXSSO\SLSLQJ
VHH7DEOHRQSDJH)RUORZSUHVVXUH/3JDVSLSHVL]HPD\EHUHGXFHGE\´ZLWKDPLQLPXPSLSHVL]HRI´
&KHFNIRUFRPSOLDQFHZLWKORFDOFRGHV
7KHKHDWHUDQGDQ\RWKHUJDVDSSOLDQFHVPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\SLSLQJV\VWHPGXULQJDQ\SUHVVXUH
WHVWLQJRQWKDWV\VWHP JUHDWHUWKDQò36, 7KHKHDWHUDQGLWVJDVFRQQHFWLRQPXVWEHOHDNWHVWHGEHIRUHSODFLQJWKH
KHDWHULQRSHUDWLRQ'RQRWXVHÀDPHWRWHVWWKHJDVOLQH8VHVRDS\ZDWHURUDQRWKHUQRQÀDPPDEOHPHWKRG
NOTE
A manual main shut-off valve must be installed externally to the heater.

WARNING
DO NOT INSTALL THE GAS LINE UNION INSIDE THE HEATER CABINET. THIS WILL VOID YOUR WARRANTY.

18–24" of 3/4" Manual


Gas line from Shut-off
Valve Valve
1" Dia. or larger
(See "Recommended
SEDIMENT TRAPS Pipe Sizes" Chart)
Bell
 Reducer
,QVWDOO D VHGLPHQW WUDS DQG XQLRQ ORFDWHG RXWVLGH
WKH KHDWHU SDQHOV LQ DFFRUGDQFH ZLWK 1DWLRQDO FRGH At least 9"
UHTXLUHPHQWV'RQRWXVHDUHVWULFWLYHJDVFRFN7KH
VHGLPHQWWUDSVKDOOEHHLWKHUDWHH¿WWLQJZLWKDFDSSHG
QLSSOHLQWKHERWWRPRXWOHWZKLFKFDQEHUHPRYHGIRU Union At least 3"
FOHDQLQJ DV VKRZQ LQ )LJXUH  RU DQ RWKHU GHYLFH Sediment
UHFRJQL]HG DV DQ HIIHFWLYH VHGLPHQW WUDS $OO JDV Trap
SLSLQJVKRXOGEHWHVWHGDIWHULQVWDOODWLRQLQDFFRUGDQFH
ZLWKORFDOFRGHV
Figure 6.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation 15

GAS PIPE SIZING


STAGE TWO “LOW PRESSURE” GAS PIPE SIZING
PIPE SIZING FOR GAS LINE CONNECTIONS
MAXIMUM EQUIVALENT PIPE LENGTH (Ft.)
Natural Gas at 1000 B.T.U. per Cubic Foot
Propane Gas at 2500 B.T.U. per Cubic Foot
1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2”
MODEL NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO
125 - 20’ 50’ 80’ 125’ 250’ 450’ 600’ - - - - - - Table 2.
TESTING GAS PRESSURE
%HIRUHRSHUDWLQJWKHKHDWHUWKHKHDWHUDQGLWVJDVFRQQHFWLRQVPXVWEHOHDNWHVWHG'R127XVHDQRSHQÀDPHWRWHVW
IRUOHDNV7HVWDOOJDVFRQQHFWLRQVIRUOHDNVZLWKVRDS\ZDWHURUDQRWKHUQRQÀDPPDEOHPHWKRG VHHSDJH 
7KHKHDWHUDQGLWVLQGLYLGXDOVKXWRIIYDOYHPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\SLSLQJV\VWHPGXULQJDQ\SUHVVXUH
WHVWLQJRIWKDWV\VWHPDWWHVWSUHVVXUHVLQH[FHVVRISVLJ N3D 7KHKHDWHUPXVWEHLVRODWHGIURPWKHJDVVXSSO\
V\VWHPE\FORVLQJLWVLQGLYLGXDOPDQXDOVKXWRIIYDOYHGXULQJDQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\DWWHVWSUHVVXUHV
HTXDOWRRUOHVVWKDQSVLJ N3D 
CHECKING THE GAS PRESSURE THROUGH THE COMBINATION GAS CONTROL VALVE

WARNING
Risk of fire and explosion. Improper installation, incorrect adjustment, alteration, service, or maintenance of the Combination
Gas Control Valve can lead to fire or explosion, causing loss of life, personal injury, and/or property damage. If it is necessary to
adjust the gas valve, this must be done by only by a qualified service agency. These instructions are for the use of qualified
service technicians only!

7KLVDSSOLDQFHLVHTXLSSHGZLWKDQXQFRQYHQWLRQDOJDVFRQWUROYDOYHWKDWLVIDFWRU\VHWZLWKDPDQLIROGSUHVVXUHRI–.2´
±FP ZF,QVWDOODWLRQRUVHUYLFHPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXSSOLHU,I
WKLVFRQWUROYDOYHLVUHSODFHGLWPXVWEHUHSODFHGZLWKDQLGHQWLFDOFRQWURO7KHFRPELQDWLRQJDVYDOYHLQFRUSRUDWHVGXDO
VKXWRIIYDOYHVDQGDQHJDWLYHSUHVVXUHUHJXODWRU)RUSURSHURSHUDWLRQWKHUHJXODWHGSUHVVXUHDWWKHRXWOHWPDQLIROGRI
WKHYDOYHPXVWEH±´ ±FP ZFEHORZWKHUHIHUHQFHSUHVVXUHDWWKHEORZHUPL[HULQOHWDQGWKHJDVYDOYHµ9(17¶
WDSPXVWEHFRQQHFWHGWRWKHHQGFDSDLURUL¿FHDVVKRZQLQ)LJXUH'RQRWDWWHPSWWRDGMXVWWKHJDVLQSXWE\

To Gas
To Air Flow Connection for Service To Air Flow Valve Vent Connection for Test
Switch Switch To High Side
of Differential
To Gas Pressure Gauge Pressure Tap
Valve Vent Inlet

Vent

Pressure Tap

To Low Side of
Figure 7. Differential Pressure Gauge

CAUTION GAS PRESSURE REQUIREMENTS


The use of Flexible Connectors (FLEX) is NOT recom- MASTERTEMP® 125 HEATER GAS PRESSURE:
mended unless they are properly sized according to NATURAL AND PROPANE:
the supplier recommendations for the heater rating. MAXIMUM INLET: 14 INCHES W.C.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
16 Section 3. Installation Instructions

OUTDOOR INSTALLATION (U.S. and Canada)



)RUKHDWHUVORFDWHGRXWGRRUVXVLQJWKHEXLOWLQVWDFNOHVVYHQWLQJV\VWHP

WARNING
Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not
install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to
determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and filling
equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquid Petroleum Gases,
ANSI/NFPA 58 (latest edition) in the U.S., or CAN/CSA B149.2 (latest edition) in Canada. Consult local codes and fire protection
authorities about specific installation restrictions.
/RFDWHWKHKHDWHURQDOHYHOVXUIDFHLQDQRSHQDUHDWKDWLVSURWHFWHGIURPGUDLQDJHRUUXQRII For Heater mounting
,QVWDOOWKHKHDWHULQDQDUHDZKHUHOHDYHVRURWKHUGHEULVZLOOQRWFROOHFWRQRUDURXQGWKHKHDWHU bolts and clamps,
purchase separately
7RDYRLGGDPDJHWRWKHHOHFWURQLFFRPSRQHQWVLQWKHKHDWHUWDNHFDUHWRSUHYHQWSURORQJHGH[SRVXUH Bolt Down Bracket Kit,
Part No. 460738.
WRGULYLQJVRXUFHVRIZDWHU VXFKDVODZQVSULQNOHUVKHDY\URRIUXQRIIKRVHVHWF $YRLGRSHUDWLRQ
LQSHUVLVWHQWH[WUHPHPRLVWRUVDOW\HQYLURQPHQWV
,QH[WUHPHZHDWKHUVKXWGRZQWKHKHDWHUDQGGLVFRQQHFWWKHSRZHUWRLWXQWLOWKHZHDWKHUKDV
Lead
PRGHUDWHG,QDUHDVVXEMHFWWRKXUULFDQHVRUYHU\KLJKZLQGVSXUFKDVHWKH%ROW'RZQ%UDFNHW Anchor

.LW31

HEATER CLEARANCES – OUTDOOR


IMPORTANT!
s )NANOUTDOORINSTALLATIONITISIMPORTANTTOENSUREWATERISDIVERTEDFROMOVERHANGING
EVESWITHAPROPERGUTTERDRAINAGESYSTEM4HEHEATERMUSTBESETONALEVELFOUNDATION
for proper drainage.
s 4HISUNITSHALLNOTBEOPERATEDOUTDOORSATTEMPERATURESBELOW o F.

,IWKHKHDWHULVORFDWHGXQGHUDURRIRYHUKDQJWKHUHPXVWEHDWOHDVWWKUHH  IHHW P RIFOHDUDQFHEHWZHHQWKHERWWRP


RIWKHRYHUKDQJDQGWKHWRSRIWKHKHDWHUH[KDXVWYHQWVHH)LJXUH,IWKHKHDWHULVXQGHUDURRIRYHUKDQJWKHVSDFH
DURXQGWKHKHDWHUPXVWEHRSHQRQWKUHHVLGHV'2127XQGHUDQ\FLUFXPVWDQFHVLQVWDOOWKHKHDWHUXQGHU$1<GHFN
)RU PLQLPXP H[KDXVW YHQW FOHDUDQFHV IRU DOO EXLOGLQJ RSHQLQJV LQFOXGLQJ EXW QRW OLPLWHG WR YHQWHG HDYHV GRRUV
ZLQGRZVJUDYLW\DLULQOHWVHH)LJXUHSDJH
,Q&DQDGDWKHKHDWHUPXVWEHLQVWDOOHGZLWKWKHWRSRIWKHYHQWDWOHDVWIHHW P 
EHORZRUWRHLWKHUVLGHRIDQ\RSHQLQJLQWRDEXLOGLQJ
2ULHQWWKHKHDWHUIRUFRQYHQLHQWDFFHVVWRWKHZDWHUFRQQHFWLRQVDQGWKHJDVDQG
HOHFWULFDOFRQQHFWLRQV
1RWH&KHFNORFDOEXLOGLQJFRGHVIRULQVWDOOLQJWKHKHDWHUIURPDQ\SURSHUW\
3 ft. (1 M) or more
OLQHVHWEDFNUHTXLUHPHQWV VHHSDJHIRULQVWDOODWLRQLOOXVWUDWLRQ 

CAUTION
If installing the heater next to or near an air conditioning unit
or a heat pump, allow a minimum of 36 in. (91.4 cm) between
the air conditioning unit and the heater.

Figure 8.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 17

OUTDOOR INSTALLATION
VENTING GUIDELINES From window or door

4'
3'
SIDE VIEW 4'
Property Line
6 in
4' es
From building wall od
i n g c nts.
ild m e
bu uire
al
l oc k req
k
Force ec bac
Exhaust Grill
Air Inlet Ch set
(Vent) for

Building

Vent Termination:
Must be at least 3 ft. above any forced
air inlet located within a 10 ft. radius.
Must be located 6 in. away from the building
wall and the following distances away from any building
wall openings, included but not limited to vented eaves,
doors, windows, gravity air inlet:
4 ft. below,
4 ft. horizontally

Figure 9.

INDOOR VENTING — General Requirements


The heater may be installed as a Category I or Category III appliance.
Vented Appliance (Category I) – Vertical only
$QDSSOLDQFHWKDWRSHUDWHVZLWKDnonpositiveYHQWVWDWLFSUHVVXUHDQGZLWKDYHQWJDVWHPSHUDWXUHWKDWDYRLGVH[FHVVLYH
FRQGHQVDWHSURGXFWLRQLQWKHYHQWVHHSDJHV
Vented Appliance (Category III) – Vertical or Horizontal
$QDSSOLDQFHWKDWRSHUDWHVZLWKDpositiveYHQWVWDWLFSUHVVXUHDQGZLWKDYHQWJDVWHPSHUDWXUHWKDWDYRLGVH[FHVVLYH
FRQGHQVDWHSURGXFWLRQLQWKHYHQWVHHSDJHV

,I\RXDUHFRQVLGHULQJFRQQHFWLQJWKLVKHDWHUWRDSUHH[LVWLQJYHQWV\VWHPPDNHVXUHWKDWWKHYHQWV\VWHPPHHWVWKH
DSSURSULDWHYHQWLQJUHTXLUHPHQWVDVJLYHQLQWKLVPDQXDORQSDJHV,IQRWUHSODFHWKHYHQWV\VWHP'2127XVH
DGUDIWKRRGZLWKWKLVKHDWHU
7KH0DVWHU7HPS®KHDWHULVDUHFDSDEOHRIDGHJUHHGLVFKDUJHURWDWLRQDQGRSHUDWHZLWKDSRVLWLYHYHQWVWDWLF
SUHVVXUHDQGZLWKDYHQWJDVWHPSHUDWXUHOHVVWKDQƒ) ƒ& 7KHWRWDOOHQJWKRIWKHKRUL]RQWDOUXQPXVWQRW
H[FHHGWKHOHQJWKWKDWLVOLVWHGLQ7DEOHRQSDJH

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
18 Section 3. Installation Instructions

HEATER CLEARANCES — General Requirements


INDOOR INSTALLATION (U.S.) OR OUTDOOR SHELTER (CANADA)
7KHIROORZLQJFOHDUDQFHVPXVWEHPDLQWDLQHGIURPFRPEXVWLEOHVXUIDFHV
(*) For service access, it is advisable to allow for
TOP...............................6 in. (15 cm) sufficient clearance on at least one door panel. 15 cm
(6 in)
EXHAUST SIDE ...........6 in. (15 cm)
HEADER SIDE .............6 in. (15 cm)
DOOR PANELS† .........6 in. (15 cm)
1RWH ‚ )RUVHUYLFHDFFHVVLWLVDGYLVDEOHWRDOORZIRUVXI¿FLHQWFOHDUDQFHRQ
DWOHDVWRQHGRRUSDQHO7KHKHDWHULVGHVLJQFHUWL¿HGE\&6$,QWHUQDWLRQDO 15 cm*
(6 in)
IRULQVWDOODWLRQRQFRPEXVWLEOHÀRRULQJ)RULQVWDOODWLRQRQFDUSHWLQJWKH 15 cm*
KHDWHUPXVWEHPRXQWHGRQDPHWDORUZRRGSDQHOWKDWH[WHQGVDWOHDVWWKUHH (6 in)

LQFKHV FP EH\RQGWKHEDVHRIWKHKHDWHU,IWKHKHDWHULVLQVWDOOHGLQD


FORVHWRUDOFRYHWKHHQWLUHÀRRUVKDOOEHFRYHUHGE\WKHSDQHO2QDQRXWGRRU
VKHOWHULQVWDOODWLRQWKHH[KDXVWGLVFKDUJHVLQWRDYHQWSLSH2ULHQWWKHKHDWHU
VRWKDWWKHYHQWSLSHGRHVQRWLQWHUIHUHZLWKDGMXVWPHQWRIWKHRSHUDWLQJ 15 cm
FRQWUROV7KHFRQWUROSDQHOORFDWHGRQWKHWRSSDQHOFDQEHURWDWHGWRDQ\ (6 in)

RIWKHWKUHHVLGHVRIWKHKHDWHUIRUHDV\DFFHVV+RZHYHUWKHFRQWUROSDQHO
PXVWQRWEHORFDWHGRQWKHVLGHZKHUHWKHYHQWLVORFDWHG VHH)LJXUH 
Figure 10.
OUTSIDE VENT COVER REMOVAL
7KHKHDWHULVVXSSOLHGIURPWKHIDFWRU\ZLWKDEXLOWLQVWDFNOHVVRXWVLGHYHQWIRURXWGRRU
LQVWDOODWLRQ5HPRYHWKHRXWVLGHYHQWFRYHUIRURXWGRRUVKHOWHULQVWDOODWLRQ

Air Supply Requirements Guide


COMBUSTION AIR SUPPLY
for MasterTemp® 125 Heater

)RULQGRRULQVWDOODWLRQWKHKHDWHUORFDWLRQPXVWSURYLGH Minimum Net Free Open Area for Each Opening*
VXI¿FLHQWDLUVXSSO\IRUSURSHUFRPEXVWLRQDQGYHQWLODWLRQ (Square Inches/Centimeters)

RIWKHVXUURXQGLQJDUHD All Air From Inside Building All Air From Outside Building
Model
7KHPLQLPXPUHTXLUHPHQWVIRUWKHDLUVXSSO\VSHFLI\WKDW Combustion Vent Combustion Vent

WKHURRPLQZKLFKDKHDWHULVLQVWDOOHGVKRXOGEHSURYLGHG 125
200 sq. in. 200 sq. in. 50 sq. in. 50 sq. in.
1290 sq. cm. 1290 sq. cm. 323 sq. cm. 323 sq. cm.
ZLWKWZRSHUPDQHQWDLUVXSSO\RSHQLQJVRQHZLWKLQ
LQFKHV FP RIWKHFHLOLQJWKHRWKHUZLWKLQLQFKHV * Area indicated is for one of two openings; one at floor level and one at the ceiling.
FP RIWKHÀRRUIRUFRPEXVWLRQDLULQDFFRUGDQFHZLWK
WKH ODWHVW HGLWLRQ RI$16, = RU WKH 1DWLRQDO )XHO Table 3.
*DV FRGH WKH &6$ % 1DWXUDO *DV DQG 3URSDQH
,QVWDOODWLRQ&RGHVDVDSSOLFDEOHDQGDQ\ORFDOFRGHVWKDW
PD\DSSO\7KHVHRSHQLQJVVKDOOGLUHFWO\RUWKURXJKGXFW
FRQQHFWWRRXWGRRUDLU

1RWH)RULQGRRULQVWDOODWLRQVZKHUHFRPEXVWLRQ
DLU PLJKW EH LQVXI¿FLHQW VHH ³'LUHFW$LU ,QWDNH
'XFWZLWKLQFK39&3LSH ,QGRRU,QVWDOODWLRQ ´
RQSDJH

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 19
$IRECT!IR)NTAKE$UCTWITH INCH06#0IPE)NDOOR)NSTALLATION
)RULQGRRUKHDWHULQVWDOODWLRQVZKHUHFRPEXVWLRQDLUVXSSO\PLJKWEHLQVXI¿FLHQWWKH0DVWHU7HPSŠ®+HDWHULV
FHUWL¿HGIRUDGLUHFWDLULQWDNHGXFWXVLQJLQFK39&SLSH,IRXWVLGHDLULVGUDZQWKURXJK´39&GXFWGLUHFWO\LQWRWKH
KHDWHU39&SLSHFDQEHLQVWDOOHGLQDFFRUGDQFHZLWKWKHIROORZLQJUHTXLUHPHQWV
7KHDLULQWDNHRSHQLQJ0867EHLQVWDOOHGDWOHDVWIWDERYHWKHURRIOLQHRUQRUPDOVQRZOHYHOVIRUIUHHDLUÀRZ7KH
&DWHJRU\,RU,,,H[KDXVWYHQWWHUPLQDWLRQFDSPXVWKDYHDWOHDVWIWPLQLPXPYHUWLFDOFOHDUDQFHIURPDLULQWDNHGXFW
6HH)LJXUHEHORZ 

Combustion 3 in. PVC Pipe


Inlet Air Intake Duct Requirements*
Combustion Air Intake 3 in. Pipe
(Vertical or Horizontal)
No. of 90° Elbows Maximum Length in Feet (M)
0 70 ft. (21.3 M)
1 58 ft. (17.7 M)
2 46 ft. (14.0 M)
3 34 ft. (10.4 M)
4 22 ft. ( 6.7 M)
Table 4.

WARNING!
DO NOT USE PVC PIPE FOR FLUE
EXHAUST VENT. FLUE EXHAUST
VENT TEMPERATURES CAN BE IN
EXCESS OF 400° F. FLUE EXHAUST
VENT MUST BE CATEGORY I or
Figure 11. CATEGORY III METAL VENT.

Note (*): Combustion Air Intake Duct Connection Kit (Call 1.800.831.7133 for part number) for all MasterTemp® 125
Heater models can be purchased separately. See page 52 for parts list.
NOTE
Each 90-degree elbow reduces the maximum horizontal PVC air intake duct run by 12 feet and each
45-degree elbow in the PVC air intake duct run reduces the maximum run by 6 feet. See the Table 5 above
for the maximum lengths using 90-degree elbows.

Corrosive Vapors and Possible Causes

Area Likely Contaminants


CAUTION
Chemicals should not be stored near the
Chlorinated swimming Pool or spa cleaning chemicals. Acids, heater installation. Combustion air can
pools and spas such as hydrochloric or muriatic acid. be contaminated by corrosive chemical
fumes which can void the warranty.
Glues and cements, construction
adhesives, paints, varnishes, and
New construction and
paint and varnish strippers. Waxes and
remodeling areas
cleaners containing calcium or sodium
chloride.

Table 5.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
20 Section 3. Installation Instructions
VENT INSTALLATION – INDOOR INSTALLATION (U.S.) OR OUTDOOR SHELTER (CANADA)
(Category I) NOTE *: Vent must be at least eight (8) feet away from
nearest vertical surface. Vents extending five (5) feet or
$OZD\VYHQWWKHKHDWHUWRWKHRXWGRRUVVHH1RWH  more above the roof must be braced or guyed.
‡9HQWLWYHUWLFDOO\XVLQJ7\SH³%´GRXEOHZDOOYHQWFRQQHFWRUSLSH Consult your local code officials for detailed information.

/RFDWHWKHKHDWHUVRDVWRPLQLPL]HWKHOHQJWKRIKRUL]RQWDOYHQWLQJDQGWKHQXPEHURIYHQWHOERZVUHTXLUHG+RUL]RQWDO
YHQWUXQVPXVWVORSHXS´SHUIRRW FP0 IURPWKHKHDWHUWRDOORZH[KDXVWFRQGHQVDWHWRGUDLQDQGLWLVUHFRPPHQGHG
WRKDYHDFRQGHQVDWHGUDLQDVGHVFULEHGLQWKHYHQWLQJLQVWDOODWLRQLQVWUXFWLRQV

VERTICAL VENTING - NEGATIVE PRESSURE


(See Figures 12, 13 and 14)
9HQW WKH KHDWHU YHUWLFDOO\ LQ D QHJDWLYH SUHVVXUH SRVLWLYH GUDIW  V\VWHP LQ
DFFRUGDQFHZLWKWKH1DWLRQDO)XHO*DV&RGH$16,=1)3$DQGRU&6$
%1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGHVDQGORFDOFRGHV7\SH³%´
Clean the Interior Surface
'RXEOHZDOOYHQWFRQQHFWRULVUHFRPPHQGHGKRZHYHUVLQJOHZDOOSLSHLVDOORZHG Vent Body
V
4" x 8" Metal
E\WKH1DWLRQDO)XHO*DV&RGHLQVRPHFLUFXPVWDQFHV&RQVXOW\RXUORFDOFRGH Flue Collar

RI¿FLDOIRUGHWDLOHGLQIRUPDWLRQ'RQRWXVHDGUDIWKRRGZLWKWKLVKHDWHU Vent Pipe

7RFRQQHFWDQHJDWLYHSUHVVXUHPHWDOJDVYHQWWRWKHKHDWHURUGHUWKHDSSURSULDWH
0HWDO)OXH&ROODUIURPWKHFKDUWEHORZ

Metal Flue Collar Part No.


Clean and RTV
4 x 6” 77707-0076 Combustion This Surface
Chamber
Flue Collar
4 x 8” 77707-0077

Figure 12.
 6HH7DEOHWRGHWHUPLQHDOORZDEOHYHQWVL]HVIRU\RXUKHDWHU
NOTICE:7DEOHLVIRULQVWDOODWLRQVLQZKLFKWKHWRWDOODWHUDOYHQWOHQJWK WKDWLVWKHKRUL]RQWDOGLVWDQFHIURPWKHÀXH
FROODUWRWKHPDLQYHUWLFDOSRUWLRQRIWKHYHQW LVOHVVWKDQWKHWRWDOYHQWKHLJKW WKHYHUWLFDOGLVWDQFHIURPWKHÀXHFROODU
WRWKHYHQWWHUPLQDWLRQ DQGZKLFKKDYHWKUHHRUOHVVHOERZVLQWKHV\VWHP)RUYHQWLQJV\VWHPVZKLFKGRQRWPHHWWKHVH
FRQGLWLRQVFRQVXOWWKH1DWLRQDO)XHO*DV&RGH$16,= 86 RUWKHVWDQGDUGV&6$%DQG% &DQDGD 

Read “VERTICAL VENTING – NEGATIVE PRESSURE” before using this table.


Table 5. – Permitted Minimum and Maximum Vent Heights By Size and Heater Model

Type "B" Double-Wall Vent with Type "B" Type "B" Double-Wall Vent with
Double-Wall Connector in Feet (Meters) Single-Wall Connector in Feet (Meters)
Model 125
Model 125 Vent Size
Vent Size Height min./max.
Height min./max.
6 in. 6 ft. (1.8)/15 ft. (4.6)
6 in. 6 ft. (1.8)/100 ft. (30.5)
7 in. 6 ft. (1.8)/8 ft. (2.4)
7 in. 6 ft. (1.8)/100 ft. (30.5)
8 in. Not Rec.
8 in. 6 ft. (1.8)/100 ft. (30.5)
9 in. Not Rec.
9 and 10 in. 6 ft. (1.8)/50 ft. (15.3)
10 in. Not Rec.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 21

NOTE
The allowable vent runs for each vent pipe diameter are different and can not be exceeded.
Each 90-degree elbow reduces the maximum horizontal vent run by 12 feet and each 45-degree elbow
in the vent run reduces the maximum vent run by 6 feet. See Table 5 on page 20 for the maximum vent
lengths using 90-degree and 45-degree elbows.
 ,QVWDOO WKH PHWDO )OXH &ROODU LQ WKH 9HQW %RG\ RI WKH
KHDWHU ORFDWHGXQGHUWKHRXWVLGHYHQWFRYHU )DVWHQWKH Listed
Termination
PHWDO)OXH&ROODUWRWKH9HQW%RG\ZLWKWZRVKHHW Cap
Min. 10 Ft.
PHWDOVFUHZV8VHKLJKWHPSHUDWXUHVLOLFRQH579WRVHDO
WKH)OXH&ROODUWRWKH9HQW%RG\%HIRUHFRQQHFWLQJWKH Storm Collar
PHWDO)OXH&ROODUWRWKH9HQW%RG\ZHWDFOHDQFORWKRU
SDSHUWRZHOZLWKLVRSURS\ODOFRKRO UXEELQJDOFRKRO DQG Flashing
YLJRURXVO\ZLSHWKHVRFNHWRIWKH9HQW%RG\,PPHGLDWHO\ 6" Minimum
Clearance to
ZLSHWKHFOHDQHGVXUIDFHVGU\ZLWKDFOHDQFORWKRUSDSHU Combustible
Materials
WRZHO5HSHDWIRUWKHH[WHULRURIWKH´HQGRIWKHPHWDO
)OXH&ROODU$WWDFKWKHPHWDO)OXH&ROODUWRWKH9HQW%RG\
XVLQJWKH579VXSSOLHGZLWKWKHNLWIROORZLQJWKHYHQW
Class B Double Wall
PDQXIDFWXUHU¶VLQVWUXFWLRQV LQFOXGHGZLWKNLW  Metal Vent Pipe Firestop

 $WWDFKWKHYHQWSLSHWRWKHPHWDO)OXH&ROODUZLWKVKHHW Metal Flue


Collar
Vent
PHWDOVFUHZV Body
Support Vertical
Vent Pipe so
adapter does not
take weight of
pipe.

WARNING Figure 13. – Typical Metal Vent Pipe Installation - U.S.


Risk of fire or asphyxiation if vent is not assembled (Vertical – Negative Pressure)
according to manufacturer’s instructions or
if vent parts from different manufacturers are
mixed. Vent parts from different manufacturers Approved
ARE NOT interchangeable. Mixing parts from Termination
Cap
more than one manufacturer may cause leaks or Min. 2 Ft. Min. 10 Ft. (3.3 M)
(.7 M)
damage to vent. When assembling a vent, pick one Storm Collar
manufacturer and be sure that all vent parts come
from that manufacturer and are specified by the
Flashing
manufacturer for your system. Follow manufacturer’s
instructions, local code requirements, National 6" (15 cm) Minimum
Clearance to Combustible
Fuel Gas Code requirements (U.S.) or standards Materials
CSA B149.1 and B149.2 (Canada) carefully during
assembly and installation.
Double Wall
Metal Vent Pipe Firestop
Metal Flue Double Wall
Vent Collar Metal Vent Tee
Body
Support Vertical
Vent Pipe so
adapter does not
take weight of
Condensate pipe. Dispose
Drain w/trap of condensate
according to
local codes.

Figure 14. – Typical Metal Vent Pipe Installation


Canada (Vertical – Negative Pressure)

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
22 Section 3. Installation Instructions

 ,QVWDOOYHQWSLSHVRWKDWLWFDQH[SDQGDQGFRQWUDFWIUHHO\DVWKHWHPSHUDWXUHFKDQJHV6XSSRUWWKHYHQWSLSHDFFRUGLQJ
WRDSSOLFDEOHFRGHVDQGWKHYHQWPDQXIDFWXUHU¶VLQVWUXFWLRQV3LSHVXSSRUWPXVWDOORZWKHYHQWSLSHIUHHPRYHPHQWRXW
DQGEDFNIURPVLGHWRVLGHRUXSDQGGRZQDVQHFHVVDU\ZLWKRXWSXWWLQJDVWUDLQRQWKHKHDWHURUYHQWERG\6ORSH
KRUL]RQWDOSLSHUXQVXSIURPWKHKHDWHUDWOHDVW´SHUIRRW FPSHUPHWHU ,QVWDOO/LVWHGFRQGHQVDWHGUDLQVDWORZ
SRLQWVZKHUHFRQGHQVDWHPLJKWFROOHFW3OXPEFRQGHQVDWHGUDLQVWRDGUDLQWKURXJKKDUGSLSLQJRUKLJKWHPSHUDWXUH
WXELQJVXFKDVVLOLFRQHUXEEHURU(3'0UXEEHU±GRQRWXVHYLQ\ORURWKHUORZWHPSHUDWXUHWXELQJ)ROORZGUDLQ
PDQXIDFWXUHU¶VLQVWDOODWLRQLQVWUXFWLRQV
 8VH/LVWHG¿UHVWRSIRUÀRRUDQGFHLOLQJSHQHWUDWLRQV8VH/LVWHGWKLPEOHIRUZDOOSHQHWUDWLRQV8VHD/LVWHGURRI
ÀDVKLQJURRIMDFNRUURRIWKLPEOHIRUDOOURRISHQHWUDWLRQV'RQRW¿OOWKHVSDFHDURXQGWKHYHQW WKDWLVWKHFOHDU
DLUVSDFHLQWKHWKLPEOHRU¿UHVWRS ZLWKLQVXODWLRQ7KHURRIRSHQLQJPXVWEHORFDWHGVRWKDWWKHYHQWLVYHUWLFDO
 'RQRWUXQWKHKHDWHUYHQWLQWRDFRPPRQYHQWZLWKDQ\RWKHUDSSOLDQFH

WARNING
Fire Hazard. Do not vent the heater directly into a masonry chimney. Installation into a masonry chimney must use a chimney
liner and must meet the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation
Codes requirements and all local code requirements.

WARNING
Risk of fire, carbon monoxide poisoning, or asphyxiation. It is recommended to use a CO Monitor and Fire Alarm in rooms
that contain gas fired appliances.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 23
HORIZONTAL OR VERTICAL VENTING - POSITIVE PRESSURE (See Figures 15, 16, and 17)
(Category III)
9HQW WKH KHDWHU HLWKHU KRUL]RQWDOO\ RU YHUWLFDOO\ XVLQJ DQ RSWLRQDO YHQW DGDSWHU RI WKH LQFK VSHFLDO JDV DSSURYHG
&DWHJRU\,,,YHQWSLSHV,QVWDOOWKHYHQWSLSHLQDFFRUGDQFHZLWKORFDOFRGHVDQGWKHSURYLVLRQVRIWKH1DWLRQDO)XHO
*DV&RGH$16,= 86 RUWKHVWDQGDUGV&6$%1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGHV &DQDGD 
DQG WKH YHQW PDQXIDFWXUHU¶V LQVWUXFWLRQV 'R QRW XVH D GUDIW KRRG ZLWK WKLV KHDWHU ,QVWDOO WKH YHQW DFFRUGLQJ WR WKH
YHQW PDQXIDFWXUHU¶V GHWDLOHG LQVWUXFWLRQV  1RWH 0DLQWDLQFOHDUDQFHEHWZHHQWKHYHQWSLSHDQGFRPEXVWLEOHVXUIDFHV
DFFRUGLQJWRWKHYHQWPDQXIDFWXUHU¶VLQVWUXFWLRQVDQGFRGHUHTXLUHPHQWV'RQRWSODFHDQ\LQVXODWLQJPDWHULDOVDURXQG
WKHYHQWRULQVLGHWKHUHTXLUHGFOHDUDLUVSDFHVXUURXQGLQJWKHYHQW6HH7DEOHIRUPD[LPXPSHUPLVVLEOHYHQWOHQJWKV

NOTE
The allowable vent runs for each vent pipe diameter are different and can not be exceeded. Each 90° elbow
reduces the maximum horizontal vent run by 12 feet and each 45-degree elbow in the vent run reduces the maximum
vent run by 6 ft. See the Table 6 below for the maximum vent lengths using 90° elbows.

7KH0DVWHU7HPSŠKHDWHULVD³&DWHJRU\,,,´DSSOLDQFH
ZKLFKUHTXLUHVDIRXU  LQFKVSHFLDOJDVDSSURYHG³&DWHJRU\ 4 in. Special Gas Vent
,,,´YHQWSLSH DQGLVDIRUFHGGUDIWSRRODQGVSDKHDWHUZKLFK (Vertical or Horizontal)
XVHVSRVLWLYHSUHVVXUHWRSXVKÀXHJDVHVWKURXJKWKHYHQWSLSHWR No. of 90° Elbows Maximum Length in Feet (M)
WKHRXWVLGH)OXHJDVHVXQGHUSRVLWLYHSUHVVXUHPD\HVFDSHLQWR 0 70 ft. (21.3 M)
WKHGZHOOLQJZLWKDQ\FUDFNVRUORRVHMRLQWVLQWKHYHQWSLSH 1 58 ft. (17.7 M)
RULPSURSHUYHQWLQVWDOODWLRQ7KHYHQWSLSHPXVWEHRIDVHDOHG 2 46 ft. (14.0 M)
VHDPFRQVWUXFWLRQVXFKDVWKRVHOLVWHGIRUXVHZLWK³&DWHJRU\ 3 34 ft. (10.4 M)
4 22 ft. ( 6.7 M)
,,,$SSOLDQFHV´DQGIRURSHUDWLQJWHPSHUDWXUHVOHVVWKDQƒ)
Table 6.
ƒ& 9HQWSLSHFRQVWUXFWLRQZLOOEHRI8/DSSURYHGQRQ
FRUURVLYHPDWHULDOVXFKDVVWDLQOHVVVWHHODOXPLQXPJDOYDQL]HG$ *Minimum vent length is one foot (.34M),
FRQGHQVDWHWUDSPD\EHQHHGHG7KHXVHRI³$SSURYHG´WKLPEOHV or in accordance with vent manufacturer’s
URRIMDFNVDQGRUVLGHYHQWWHUPLQDOVDUHUHTXLUHGDQGWKHSURSHU
instruction, and local and national codes.
FOHDUDQFHVWRFRPEXVWLEOHPDWHULDOVPXVWEHPDLQWDLQHGLQ
Horizontal vents 3’(1M) or less in length
DFFRUGDQFHZLWKW\SHRIYHQWSLSHHPSOR\HG²LQWKHDEVHQFHRI
DFOHDUDQFHUHFRPPHQGDWLRQE\WKHYHQWSLSHPDQXIDFWXUHUWKH do not require a condensate tee, but must
UHTXLUHPHQWVRIWKH8QLIRUP0HFKDQLFDO&RGHVKRXOGEHPHW7KH slope down toward the outlet at 1/4” to the
YHQWLODWLRQDLUUHTXLUHPHQWVIRUWKH0DVWHU7HPS®KHDWHU foot (2cm/M) to allow condensate to drain.
DUHVKRZQRQSDJH.,WLVUHFRPPHQGHGWKDWYHQWUXQVRYHUIHHW
PD\QHHGWREHLQVXODWHGWRUHGXFHFRQGHQVDWLRQUHODWHGSUREOHPVDQG
RUWKHXVHRIDFRQGHQVDWHWUDSLQWKHYHQWUXQFORVHWRWKHKHDWHUPD\EH
CAUTION
QHFHVVDU\LQFHUWDLQLQVWDOODWLRQVVXFKDVFROGFOLPDWHV+RUL]RQWDO Do NOT combine exhaust vent pipes to a
YHQWV¶ 0 RUOHVVLQOHQJWKGRQRWUHTXLUHDFRQGHQVDWHWHH7KH common exhaust vent in multiple unit
0DVWHU7HPSŠKHDWHULVVXLWDEOHIRUWKURXJKWKHZDOOYHQWLQJ installations. Run separate vent pipes.

CONNECTING SPECIAL METALIC GAS VENT TO THE HEATER


 2UGHUDQRSWLRQDODSSOLDQFHDGDSWHUNLW(3HQWDLURIIHUVRSWLRQDODSSOLDQFHDGDSWHUNLWVFDOO&XVWRPHU6HUYLFHDW
 IRUPRUHLQIRUPDWLRQ 3DUW1RIRU6DI79HQWŠRU6DI79HQWŠ&,3DUW1R
IRU=9HQW
 5HPRYHWKHRXWVLGHYHQWFRYHU
 ,QVWDOOWKH$SSOLDQFH$GDSWHULQWKH9HQW%RG\RIWKHKHDWHU ORFDWHGXQGHUWKHRXWVLGH9HQW&RYHU %HIRUH
FRQQHFWLQJWKH$SSOLDQFH$GDSWHUWRWKH9HQW%RG\ZHWDFOHDQFORWKRUSDSHUWRZHOZLWKLVRSURS\ODOFRKRO
UXEELQJDOFRKRO DQGYLJRURXVO\ZLSHWKHVRFNHWRIWKH9HQW%RG\,PPHGLDWHO\ZLSHWKHFOHDQHGVXUIDFHVGU\
ZLWKDFOHDQFORWKRUSDSHUWRZHO5HSHDWIRUWKHH[WHULRURIWKHKHDWHUHQGRIWKH$SSOLDQFH$GDSWHU$WWDFKWKH
DSSOLDQFHDGDSWHUWRWKHYHQWERG\XVLQJWKHDGKHVLYHVSHFL¿HGE\WKHYHQWPDQXIDFWXUHUIROORZLQJWKHYHQW
PDQXIDFWXUHU¶VLQVWUXFWLRQV

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
24 Section 3. Installation Instructions

WARNING
Risk of carbon monoxide poisoning if adapter is improperly attached. Mechanical connections (such as screws) can cause
cracking and leaks in the adapter. Do NOT drill holes or use screws to connect the appliance adapter to the heater vent body.
Attach with manufacturer’s specified adhesive.

WARNING
Risk of fire or asphyxiation if vent is not assembled according to manufacturer’s instructions or if vent parts from different
manufacturers are mixed. Vent parts from different manufacturers ARE NOT interchangeable. Mixing parts from more than one
manufacturer may cause leaks or damage to vent. When installing a vent, pick one manufacturer and be sure that all vent parts
come from that manufacturer and are specified by the manufacturer for your system. Follow manufacturer’s instructions and
local and National Fuel Gas Code (U.S.) or CSA B149.1, Natural Gas and Propane Installation Codes (Canada) requirements
carefully during assembly and installation.

 ,QVWDOOYHQWSLSHVRWKDWLWFDQH[SDQGDQGFRQWUDFWIUHHO\DV Vent Cap and Chimney or Gas Vent


WKHWHPSHUDWXUHFKDQJHV6XSSRUWWKHYHQWSLSHDFFRUGLQJ Riser Furnished
by Installer
WR DSSOLFDEOH FRGHV DQG YHQW PDQXIDFWXUHU¶V LQVWUXFWLRQV
3LSHVXSSRUWPXVWDOORZWKHYHQWSLSHIUHHPRYHPHQWRXW
DQGEDFNIURPVLGHWRVLGHRUXSDQGGRZQDVQHFHVVDU\
ZLWKRXW SXWWLQJ D VWUDLQ RQ WKH KHDWHU RU YHQW ERG\ ,W LV
UHFRPPHQGHGWRVORSHWKHKRUL]RQWDOSLSHUXQVXSIURPWKH
KHDWHU DW OHDVW ´ SHU IRRW FP0  ,QVWDOO ³$SSURYHG´ Outlet Air
Opening
FRQGHQVDWH GUDLQV DW ORZ SRLQWV ZKHUH FRQGHQVDWH PLJKW
FROOHFW 3OXPE FRQGHQVDWH GUDLQV WR D GUDLQ WKURXJK KDUG
SLSLQJRUKLJKWHPSHUDWXUHWXELQJVXFKDVVLOLFRQHUXEEHURU
(3'0UXEEHU±GRQRWXVHYLQ\ORURWKHUORZWHPSHUDWXUH
WXELQJ)ROORZGUDLQPDQXIDFWXUHU¶VLQVWDOODWLRQLQVWUXFWLRQV
Side
 8VHDQ³$SSURYHG´¿UHVWRSIRUÀRRUDQGFHLOLQJSHQHWUDWLRQV Wall Vent
Inlet Air
Opening
8VHDQ³$SSURYHG´WKLPEOHIRUZDOOSHQHWUDWLRQV8VHDQ
³$SSURYHG´ URRI ÀDVKLQJ URRI MDFN RU URRI WKLPEOH IRU
DOOURRISHQHWUDWLRQV'RQRW¿OOWKHVSDFHDURXQGWKHYHQW Figure 15.

WKDWLVWKHFOHDUDLUVSDFHLQWKHWKLPEOHRU¿UHVWRS ZLWK
LQVXODWLRQ7KHURRIRSHQLQJPXVWEHORFDWHGVRWKDWWKHYHQW
Chimney or Gas Vent
LVYHUWLFDO Vent Cap and
Riser Furnished
 9HQW7HUPLQDWLRQ±9HUWLFDO 6HH)LJXUHVDQG IRU by Installer

KHLJKWRIYHQWWHUPLQDWLRQDERYHWKHURRI8VHDQ³$SSURYHG´
YHQW WHUPLQDO VSHFL¿HG E\ ORFDO DQG QDWLRQDO FRGHV DQG
\RXUPDQXIDFWXUHU¶VLQVWUXFWLRQV$URRIWHUPLQDWLRQPXVW
EH YHUWLFDO ,Q &DQDGD WKH 9HQW &DS ORFDWLRQ VKDOO KDYH
D PLQLPXP FOHDUDQFH RI  IHHW 0  KRUL]RQWDOO\ IURP Outlet Air Opening
HOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIRSHQLQJV
 0DNHVXUHHQWLUHLQVWDOODWLRQLVVHDOHGDFFRUGLQJWRDSSURYHG
VWDQGDUG

Side
Wall Vent Inlet Air Opening

Heater

Figure 16.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 25

Max. 12"
4' Min. 4' Min.
Min. 3"
Vent Vent
Termination Termination Vent
4' Min. Termination

1' Min.
4' Min.

At least 7'
above grade
1' Minimum adjacent
Gas Meter to public
above snow or Forced Air
finished grade walkways
Inlet 3' Minimum clearance if
(whichever is
higher) horizontal distance to
exhaust opening is less
than 10 feet.

Figure 17.
 9HQW7HUPLQDWLRQ±+RUL]RQWDO
7KHWHUPLQDOPXVWEHORFDWHG 86±6HH)LJXUH 
‡ DWOHDVW´DQGDWPRVW´RXWIURPWKHZDOO VHH)LJXUH IROORZLQJWKHYHQWPDQXIDFWXUHU¶VLQVWUXFWLRQV
‡ DWOHDVW´DERYH¿QLVKHGJUDGHRUWKHQRUPDOO\H[SHFWHGVQRZDFFXPXODWLRQOHYHOZKLFKHYHULVKLJKHU
‡ DWOHDVWIHHWEHORZRUKRUL]RQWDOO\IURPRUIRRWDERYHDQ\GRRUVRUZLQGRZVRUJUDYLW\DLULQOHWWRDEXLOGLQJ
‡ DWOHDVWIHHWDERYHDQ\IRUFHGDLULQOHWORFDWHGZLWKLQIHHW
‡ DWOHDVWIHHWKRUL]RQWDOO\IURPHOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIHTXLSPHQW
‡ DWOHDVWIHHWDERYHJUDGHDGMDFHQWWRZDONZD\VRUVLPLODUWUDI¿FDUHDV
7KHWHUPLQDOPXVWEHORFDWHG &DQDGD±6HH)LJXUH 
‡ DWOHDVWIHHW 0 IURPDQ\RSHQLQJLQWRDEXLOGLQJ
‡ DWOHDVW´ 0 DERYH¿QLVKHGJUDGHRUWKHQRUPDOO\H[SHFWHGVQRZDFFXPXODWLRQOHYHOZKLFKHYHULVKLJKHU
‡ DWOHDVWIHHW 0 KRUL]RQWDOO\IURPHOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIHTXLSPHQW
‡ DWOHDVWIHHW 0 DERYHJUDGHDGMDFHQWWRZDONZD\VRUVLPLODUWUDI¿FDUHDV
$OORZ DW OHDVW WKUHH IHHW 0  YHUWLFDO FOHDUDQFH
RYHU YHQW WHUPLQDWLRQ ZKHQ WHUPLQDWLQJ XQGHU DQ Metal Special
Support
Gas Vent
RYHUKDQJ requires weight
Appliance of pipe
$YRLGFRUQHUVRUDOFRYHVZKHUHVQRZRUZLQGFRXOG Adapter
Listed
Terminal
KDYH DQ HIIHFW ([KDXVW PD\ DIIHFW VKUXEEHU\ DQG Condensate
Tee
VRPHEXLOGLQJPDWHULDOV.HHSVKUXEEHU\DZD\IURP Metal
WHUPLQDWLRQ 7R SUHYHQW VWDLQLQJ RU GHWHULRUDWLRQ Vent
Body
VHDOLQJ RU VKLHOGLQJ H[SRVHG VXUIDFHV PD\ EH
UHTXLUHG
Slope at least
1/4" per foot
WARNING Condensate
drain w/Trap
(2 cm per Meter)
down towards 3" (7.6 cm) Min.,
(Optional) condensate drain 12" (30.5 cm) Ma
Fire Hazard. Do not run the heater vent into a common Clearance
vent with any other appliance. Do not run the Special
Gas Vent into, through, or within any active vent such
Figure 18.
®
Rev. B 8/14 MASTERTEMP 125 Pool and Spa Heater Installation and User’s Guide
26 Section 3. Installation Instructions

OUTDOOR SHELTER INSTALLATION


,Q&DQDGDWKLVSRROKHDWHUFDQRQO\EHLQVWDOOHGRXWGRRUVRULQDQHQFORVXUHWKDWLVQRWQRUPDOO\RFFXSLHGDQGKDVQR
GLUHFWRSHQLQJVLQWRRFFXSLHGDUHDV

WARNING
Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly when installing heater. Do not
use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust
fumes to blow into the room housing the heater. Exhaust venting to the outdoors is required for all outdoor shelter installations.

WARNING
Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do
not install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials
to determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and
filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquefied Petroleum
Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). Consult local codes and fire protection authorities
about specific installation restrictions.

7KHKHDWHULVGHVLJQFHUWL¿HGE\&6$,QWHUQDWLRQDOIRULQVWDOODWLRQRQFRPEXVWLEOHÀRRULQJLQDOFRYHVEDVHPHQWVLQ
FORVHWRUXWLOLW\URRPV LQWKH86 

GARAGE OR UTILITY ROOM INSTALLATION


,Q&DQDGDWKHKHDWHUPXVWEHLQVWDOOHGLQDURRPWKDWLVQRWQRUPDOO\RFFXSLHGDQGKDVQRRSHQLQJV
GLUHFWO\WRRFFXSLHGDUHDV

WARNING
Risk of fire and explosion if installed at floor level in an automotive garage or near gasoline or flammable liquid storage.
Gasoline fumes are heavier than air and will settle to floor level in closed spaces. Gasoline fumes and spilled gasoline or other
volatile liquids (such as some paints and varnishes) will travel across the floor and can be ignited by a gas appliance.

,QDQ\XWLOLW\URRPRUUHVLGHQWLDOJDUDJHLQVWDOODWLRQLQVWDOOWKHKHDWHUZLWKWKHEDVHDWOHDVWLQFKHV 0 DERYHWKH


ÀRRUVHH)LJXUH,QDJDUDJHLQVWDOODUDLORUZDOOWRSURWHFWWKHKHDWHUIURPSK\VLFDOGDPDJHE\DPRYLQJYHKLFOH
3URYLGHDQDGHTXDWHYHQWLODWLRQDLUVXSSO\ 6HH7DEOHSDJH &KRRVHDORFDWLRQWKDWZLOODYRLGFRQWDPLQDWLRQ
E\FKHPLFDOIXPHV
Leave 3 ft. (1 m)

CAUTION or more of clearance


above heater

A Propane (LPG) fired heater must not be installed in a garage in


Massachusetts, by order of the Massachusetts State Fire Marshal. For
more information, call the Massachusetts State Fire Marshal’s office.
Leave 6 in. (15 cm)
127,&(&RPEXVWLRQDLUFRQWDPLQDWHGE\FRUURVLYHFKHPLFDOIXPHV of clear space between
heater and combustible
FDQGDPDJHWKHKHDWHUDQGZLOOYRLGWKHZDUUDQW\ surface.
6HH7DEOHSDJH 

RAISE AT LEAST
18 in. (46 cm) above floor 18 in.
to avoid flammable vapors

Figure 19.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 27

CONTROL PANEL INDEXING


2QDQRXWGRRUVKHOWHULQVWDOODWLRQWKHH[KDXVWGLVFKDUJHVLQWRDYHQWSLSH2ULHQWWKHKHDWHUVRWKDWWKHYHQWSLSHGRHV
QRWLQWHUIHUHZLWKDGMXVWPHQWRIWKHRSHUDWLQJFRQWUROV7KHFRQWUROSDQHOORFDWHGRQWKHWRSSDQHOFDQEHURWDWHGWRDQ\
RIWKHWKUHHVLGHVRIWKHKHDWHUIRUHDV\DFFHVVVHH)LJXUH
 5HPRYHWKHEROWVIURPWKHGRRUSDQHOV5HPRYHERWKGRRUDFFHVVSDQHOV
 5HPRYHWKHIRXUFRUQHUZLQJQXWVWKDWVHFXUHWKHWRSSDQHO/LIWWKHWRSSDQHOXSZDUGWRUHPRYHWKHWRSSDQHO
 5RWDWHWKHWRSSDQHOWRWKHGHVLUHGSRVLWLRQORFDWHGDWƒDQJOHV1RWHWKDWWKHFRQWUROSDQHOPXVW127EHORFDWHG
RQWKHVLGHZKHUHWKHYHQWLVORFDWHG
 5HSODFHWKHWRSSDQHOGRZQRQWRWKHVLGHSDQHOV%HVXUHWKDWWKHUHDUHQRZLUHVFDXJKWXQGHUWKHSDQHO
 6HFXUHWKHWRSSDQHOXVLQJWKHIRXUFRUQHUZLQJQXWV
 5HDWWDFKWKHGRRUDFFHVVSDQHOV

Top Panel
Door Acess Panel
Door Acess Panel

Figure 20.

FINAL INSTALLATION CHECK


&KHFNWKDWKRUL]RQWDOYHQWSLSHUXQVVORSHXQLIRUPO\DWOHDVW´SHUIRRW FPSHU
PHWHU WRFRQGHQVDWHGUDLQ V 1RVDJVQRGLSVQRKLJKRUORZVSRWV For Heater mounting
bolts and clamps,
&KHFNWKDWYHQWLVVXSSRUWHGDWHOERZVWHHVDQGKRUL]RQWDODQGYHUWLFDOUXQVDFFRUGLQJ purchase separately
WRPDQXIDFWXUHU¶VLQVWUXFWLRQVDQGFRGHUHTXLUHPHQWV Bolt Down Bracket Kit,
Part No. 460738.
&KHFNWKDWYHQWVXSSRUWVDQGZDOODQGFHLOLQJSHQHWUDWLRQVDOORZIUHHPRYHPHQWVXS
GRZQDQGVLGHZD\VZLWKRXWSXWWLQJDQ\VWUDLQVRQWKHKHDWHURUYHQWERG\
&KHFNIRUDWOHDVWVL[LQFK FP IUHHDLUFOHDUDQFHEHWZHHQWKHKHDWHUYHQWSLSHDQG
FRPEXVWLEOHPDWHULDOV
Lead
Anchor
&KHFNWKDWDOOMRLQWVDUHFRPSOHWHO\WRJHWKHUDQGVHDOHG
,Q)ORULGDEXLOGLQJFRGHVUHTXLUHWKDWWKHKHDWHUEHDQFKRUHGWRWKHHTXLSPHQWSDG
RUSODWIRUPWRZLWKVWDQGKLJKZLQGSUHVVXUHVFUHDWHGGXULQJKXUULFDQHV$%ROW'RZQ
%UDFNHW.LW31LVDYDLODEOHZLWKDQFKRUFODPSVGHVLJQHGWRKROGWKHXQLW
WRWKHHTXLSPHQWSDGLQKLJKZLQGFRQGLWLRQV,QVWDOODWLRQRIWKHDQFKRUFODPSVDUH
UHFRPPHQGHGLQDOOLQVWDOODWLRQVDQGDUHUHTXLUHGLQ)ORULGD 6HH)ORULGD%XLOGLQJ
&RGH 

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
28 Section 3. Installation Instructions

ELECTRICAL CONNECTIONS
(OHFWULFDO5DWLQJ+]9ROWV$&VLQJOHSKDVH
(QFORVHWKHLQFRPLQJ$&SRZHUOLQHWRWKHKHDWHULQDQDSSURYHGÀH[LEOHFRQGXLWFRQQHFWHGGLUHFWO\WRWKHMXQFWLRQER[
RQWKHLQVLGHRIWKHDFFHVVGRRUSDQHO/LQHYROWDJH¿HOGZLULQJVKRXOGEHJDXJHZLWKDFLUFXLWFDSDFLW\RI$PSV

CAUTION
This heater is designed to operate at 120 or 240 VAC. It is not recommended to be connected to OR operate on a 208 VAC.

NOTE
s Before making any electrical connections to the power supply, remove the access door panels,
open the control box and plug in the correct plug (120 volt or 240 volt).

CAUTION
The heater ships from the Factory with the 240V plug installed. Installing the 120V plug and then connecting the heater
to 240V line current will immediately destroy the transformer, control board and ignition control module, and will void
warranty. If you install the 240V plug and connect the heater to 120 volts line current, the heater will not operate.

s )FANYOFTHEORIGINALWIRINGSUPPLIEDWITHTHISHEATERMUSTBEREPLACED INSTALLERMUSTSUPPLY.O!7' 6 ½#5,


approved AWM low energy stranded) copper wire or it’s equivalent.

3OHDVHUHDGWKHER[HVKHDGHG³,03257$175($'0(),567´RQSDJHVDQG45EHIRUHSURFHHGLQJ
 $OOZLULQJPXVWEHLQDFFRUGDQFHZLWKDOODSSOLFDEOHFRGHV
 7KHKHDWHUZKHQLQVWDOOHGPXVWEHHOHFWULFDOO\JURXQGHGDQGERQGHGLQDFFRUGDQFHZLWKORFDOFRGHVRULQWKHDEVHQFH
RIORFDOFRGHVZLWKWKH1DWLRQDO(OHFWULFDO&RGHRUWKH&DQDGLDQ(OHFWULFDO&RGH DVDSSOLFDEOH $ERQGLQJOXJLV
SURYLGHGRQWKHRXWVLGHRIWKHSDQHOXQGHUWKHYHQWIRUWKLVSXUSRVH
 (OHFWULFDOSRZHUFLUFXLWVWRWKHSRROKHDWHUPXVWIROORZORFDOFRGHVDQG1DWLRQDO(OHFWULFDO&RGHRU&DQDGLDQ(OHFWULFDO
&RGH DVDSSOLFDEOH 
 $OOZLULQJEHWZHHQWKHKHDWHUDQGGHYLFHVQRWDWWDFKHGWRLWRUEHWZHHQVHSDUDWHGHYLFHVZKLFKDUHLQVWDOOHGLQWKH
¿HOGPXVWEH³7\SH7´ZLUHUDWHGIRUƒ&ULVH
 $OOOLQHYROWDJHZLULQJVKDOOEHHQFORVHGLQDSSURYHGÀH[LEOHFRQGXLWDQGVKDOOEHVHFXUHO\DWWDFKHGWRWKH¿HOG
ZLULQJER[ORFDWHGLQVLGHWKHDFFHVVGRRUSDQHO7KHFRQGXLWRUFDEOHFRQQHFWRUDWWKH¿HOGZLULQJER[VKRXOGFRQWDLQ
DQLQVXODWLQJEXVKLQJRULWVHTXLYDOHQWWRSUHYHQWDEUDVLRQRIWKHZLUHVDVWKH\HQWHUWKHER[
 7KH¿OWHUSXPSVKRXOGUXQFRQWLQXRXVO\ZKHQWKHKHDWHULVRQDQGIRUDWOHDVWPLQXWHVDIWHUWKHKHDWHUWXUQV
RII$Q\VZLWFKHVLQWKHSXPSFLUFXLW LQFOXGLQJFLUFXLWEUHDNHUV WKDW
FDQGLVFRQQHFWWKHSXPSPXVWDOVRGLVFRQQHFWWKHKHDWHU
 'RQRWZLUHVLQJOHSROHVZLWFKHVLQFOXGLQJSURWHFWLYHGHYLFHVLQWRD
JURXQGHGOLQH7KHKHDWHULVQRWVHQVLWLYHWRSRODULW\
&RQQHFWWKHL1RIWKHSRZHUVXSSO\WRWKHEODFNZLUHWKHL2RUQHXWUDO
OHDGWRWKHredZLUHDQGWKHJURXQGZLUHWRWKHgreenZLUH$WLPHFORFN
FRQWUROOLQJWKH¿OWHUSXPSVKRXOGKDYHDORZYROWDJH)LUHPDQ¶V6ZLWFKWKDW
VZLWFKHVRIIWKHKHDWHUDWOHDVWPLQXWHVEHIRUHVKXWWLQJRIIWKHSXPS
$OZD\VXVHFULPSW\SHFRQQHFWRUVZKHQFRQQHFWLQJWZRZLUHV

AC Plug
120 Volt
or
240 Volt

Figure 21

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 29

CONNECTION OF FIREMAN’S SWITCH OR REMOTE CONTACT

CAUTION
If, while there is line voltage connected to the heater, you touch either line voltage terminal with any 24VAC wire that
is connected to the control board (including the Fireman’s Switch jumper), you will immediately destroy the control
board and void the warranty.
Figure 22
REMOTE CONTROL CONNECTIONS
 6ZLWFKRIISRZHUWRKHDWHUDWPDLQFLUFXLWEUHDNHUSDQHO
 8QEROWDQGUHPRYHWKHDFFHVVGRRUSDQHOV
 2SHQFRQWUROER[FRYHU VHH)LJXUH 
D To connect a 2-Wire Control VXFK DV ,QWHOOL7RXFK® RU (DV\7RXFKŠ &RQWURO
6\VWHP or a timer:
 5HPRYHWKHIDFWRU\LQVWDOOHGMXPSHUIURPWKH)LUHPDQ¶V6ZLWFKWHUPLQDOV
 &RQQHFWZLUHVEHWZHHQWKH)LUHPDQ¶V6ZLWFKWHUPLQDOVRQWKHKHDWHUDQGWKH
UHOD\&RQQHFWZLUHVIURPWKHFRQWUROOHURUWLPHUWRWKH)LUHPDQ¶V6ZLWFK
&RQWUROOHU WLPHU RU UHOD\ VKRXOG EH VL]HG WR KDQGOH 9$& DW $PS
EHFDXVHLWZLOOEHFRPSOHWLQJWKH9$&FRQWUROERDUGFLUFXLWRQWKHKHDWHU
DVVKRZQLQ)LJXUH '2127DSSO\OLQHYROWDJHWRWKH)LUHPDQ¶V6ZLWFK
WHUPLQDOV8VHJDXJHZLUHZLWKDPLQLPXP´ PP WKLFNLQVXODWLRQ
UDWHGIRUDWHPSHUDWXUHULVHRIDWOHDVWƒ&
 .QRFNRXWVDUHSURYLGHGWRURXWHWKHZLUHVWKURXJK BK
O
WKHERWWRPRIWKHFRQWUROER[DQGSDVWWKHMXQFWLRQ TRANS Y
Y
ER[
E To connect a 3-Wire Control: Y Y 24 VAC
 &RQQHFWZLUHVEHWZHHQWKHFRQWUROERDUGWHUPLQDOV
THERMISTOR
VAL
TH
IND
GND
24VAC

24VAC
FS

RQWKHKHDWHUDQGWKHH[WHUQDOUHOD\VDVVKRZQLQ J6

1
)LJXUH8VHDWOHDVWUHOD\VSHUKHDWHUWRDOORZ
IRUDQ³2))VHWWLQJ´RQHDFKKHDWHUPRGH6HOHFW OPERATING CONTROL
BK O
UHOD\VWKDWFDQKDQGOHORJLFOHYHOVZLWFKLQJ'2127 MEMBRANE PAD
CONNECTION
DSSO\OLQHYROWDJHWRFRQWUROERDUGWHUPLQDOV ENABLE TOGGLE
9

DISABLE TOGGLE

 0RYH MXPSHU DV VKRZQ RQ )LJXUH   WR HQDEOH


FUSE

FUSE W
H[WHUQDOFRQWURODQGWRGLVDEOHWKHKHDWHUPHPEUDQH
SDG¶V³3RRO21´DQG³6SD21´EXWWRQV WKH³2))´ TERMINAL BOARD TRANS
NH\RQWKHPHPEUDQHSDGUHPDLQVIXQFWLRQDO 
W
 .QRFNRXWVDUHSURYLGHGWRURXWHWKHZLUHVWKURXJK F
I S
TRAN S
W
WKHERWWRPDQGWKHWRSRIWKHFRQWUROER[DQGSDVW
R
E I W
L1 M FL T
L2
A C

WKHMXQFWLRQER[ F1
N
S
H
BM
R

 &ORVHFRQWUROER[FRYHU L1 L2
R

 5HLQVWDOOWKHDFFHVVGRRUSDQHOV
7R FRQWURO KHDWHUV WKDW DUH RSHUDWHG LQ SDUDOOHO FRQQHFW GND
BK

ZLULQJ DW VDPH ORFDWLRQV RQ KHDWHU DV :LUH RU :LUH
JUNCTION

Time Clock or Remote


BOX

&RQWURO,WLVLPSHUDWLYHWKDWHDFKFRQWUROFLUFXLWLVLVRODWHG (Purchase Separately –


Supplies Power to
IURP WKH RWKHU FRQWURO FLUFXLWV WR DYRLG WKDW FXUUHQW ZLOO Circulator Pump)
ÀRZIURPRQHKHDWHUWRDQRWKHUWKURXJKWKHFRQWUROFLUFXLWV Fireman's Switch
GROUND (GND )
L1
L2

Completes the heater


24 Volt AC Control
127,&(7KHIXVHIRUWKH)LUHPDQ¶V6ZLWFKLVD$PS
Receptacle

Board Circuit.
ó[ó´IDVWEORZIXVHZKLFKLVFRPPRQO\DYDLODEOH DO NOT connect this
12 Pin

24VAC circuit to Line Voltage!

Figure 23.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
30 Section 3. Installation Instructions

HEATER WIRING DIAGRAM


(3-WIRE SYSTEM)

CONNECTION DIAGRAM
AGS Switch Air Flow Switch
Stack Flue Sensor Extra Switch 1 Y/R

Gas Valve Hi-Limit Switch Y/BL


Y/O
Pressure Switch
Y/W
Y

Y
O Y
BL O Y
BL O
W Y
O
W BR
Y/W PR BR
R PR
Y R

THERMISTOR
FS
GND
PS

24VAC
IND
VAL
TH

24VAC
NA/LP
HLS Models Only
ES1 Y/W Y/BL
J6 Y Y/O Y/R Y Y Y Y

1
AFS OPERATING CONTROL
MEMBRANE PAD
AGS CONNECTION

SFS
JMP3

6
GAS
1

External Control Interface Circuit Disabled,


Heater Membrane Pad Enabled Spa Line
Common Line
Pool Line
JMP External Control Interface
W Y

BK
1
JMP F1
24
F2 VAC

DIAGNOSTIC INDICATOR IGNITION CONTROL


MODULE
1 Y Y

External Control Interface Circuit 24 VAC


Enabled, "Pool On" and "Spa On" S1 S1/ SEC
240 120 L1 L2 S2 TH IND VAL GND
Keys Disabled. "OFF" Key on
Membrane Pad Remains Functional.
Y/W
GY GY BK GY
Y/O
Y/BL W

Y/R
BK O
120 VAC
IGNITER Y/W
W
GND
BK
TRAN S
Plug –12 pin O F
I S
GY R W
120V – Black BK
L1 E
M FL
I
T
L2
240V – Red BK
A
N
C
H
F1 S BM
BK
1
GY Y R R W
W
R
GY R
12 Position
Receptacle
Switch (field installed)
Replace jumper with

W W R
leads to Fireman"s

BK BK
Y Y
BLOWER
BL BL

JUNCTION BOX NOTICE: Touching any 24VAC wire, including G

Line 1 BK the Fireman's Switch wire, to any 120/240V


R
terminal while the heater is connected to line GND
Line 2
power will immediately destroy the control
Ground G board and void the warranty.
Figure 24.
GND

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 3. Installation Instructions 31

HEATER ELECTRICAL SCHEMATIC LADDER DIAGRAM

LADDER DIAGRAM
L1 120/240 L2
VAC

IGNITER

L1 S1 S2 L2

F1 F2 BLOWER

GND
120/240
VAC

CLASS II
TRANSFORMER

24 VAC

OPERATING
CONTROL
24 VAC

24 VAC GND

AIR
24V LOGIC FLOW
SWITCH
TH

WATER HI
PRESSURE LIMIT
SWITCH SWITCH
IND
COM NO

AGS
SWITCH
VAL

GAS VALVE

STACK FLUE
THERMISTOR
SENSOR
SENSOR

NOTES:
1.) L1 L2 F1 F2 S1 24 VAC

S2 GND IND VAL AND TH

ARE CONNECTED ON THE IGNITION MODULE.

2. ) PIN AND SOCKET CONNECTOR.


3. ) IF ANY OF THE ORIGINAL WIRES AS SUPPLIED
WITH THE APPLIANCE MUST BE REPLACED,
Figure 25.
THEY MUST BE REPLACED WITH TYPE 105˚ C
OR ITS EQUIVALENT.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
32 Section 4. Operation Instructions

Operation Instructions
BASIC SYSTEM OPERATION

6WDUWSXPSPDNHVXUHWKHSXPSLVUXQQLQJDQGLVSULPHGWRFORVHWKHZDWHUSUHVVXUHVZLWFKDQGVXSSO\SRZHU
WRKHDWHU%HVXUHWKHSRRODQGRUVSDLVSURSHUO\¿OOHGZLWKZDWHU)ROORZWKH/LJKWLQJ2SHUDWLQJLQVWUXFWLRQVEHORZ

(%!4%2(3)%,%#42/.)#)'.)4)/.,)'(4).'/0%2!4)/.

FOR YOUR SAFETY: READ BEFORE LIGHTING

WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Do not attempt to light the heater if you suspect a gas leak. Lighting the heater can result in a fire or
explosion which can cause personal injury, death, and property damage.

START-UP AND OPERATION


START-UP AND SHUTDOWN INSTRUCTIONS ARE ON THE LABEL ATTACHED TO THE COVER OF THE APPLIANCE
CONTROL BOX.
) %HIRUH RSHUDWLQJ WKH DSSOLDQFH IRU WKH ¿UVW WLPH RU
BEFORE START-UP
DIWHULWKDVEHHQRIIIRUDQH[WHQGHGWLPHSHUIRUPWKH
$7KLV DSSOLDQFH GRHV QRW KDYH D SLORW ,W LV HTXLSSHG IROORZLQJFKHFNOLVW
ZLWKDQLJQLWLRQGHYLFHZKLFKDXWRPDWLFDOO\OLJKWVWKH
 5HPRYHGHEULVRURWKHUDUWLFOHVIURPLQVLGHWKHKHDWHU
EXUQHUV'RQRWWU\WROLJKWWKHEXUQHUVE\KDQG
DQGWKHDUHDDURXQGWKHKHDWHUDQGLWVH[KDXVWYHQW
%%()25(23(5$7,1*VPHOODOODURXQGWKHDSSOLDQFH 0DNHVXUHWKHYHQWLODWLRQRSHQLQJVDUHFOHDURIGHEULV
DUHDIRUJDV%HVXUHWRVPHOOQH[WWRWKHÀRRUEHFDXVH RUREVWUXFWLRQ)RULQVWDOODWLRQVLQDQHQFORVHGVSDFH
VRPHJDVLVKHDYLHUWKDQDLUDQGZLOOVHWWOHRQWKHÀRRU PDNHVXUHRSHQLQJVIRUFRPEXVWLRQDQGYHQWLODWLRQ
WHAT TO DO IF YOU SMELL GAS DLUDUHXQREVWUXFWHG
± 'RQRWWU\WROLJKWDQ\DSSOLDQFH  .HHSKHDWHUDUHDFOHDUDQGIUHHIURPFRPEXVWLEOHV
± 'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRWXVHDQ\SKRQH ÀDPPDEOHOLTXLGVDQGFKHPLFDOV
LQ\RXUEXLOGLQJ  &KHFNWKDWDOOZDWHUFRQQHFWLRQVDUHWLJKW
± ,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU¶V  :DWHU PXVW EH ÀRZLQJ WKURXJK WKH KHDWHU GXULQJ
SKRQH)ROORZWKHJDVVXSSOLHU¶VLQVWUXFWLRQV RSHUDWLRQ0DNHVXUHWKDWSRROVSDLV¿OOHGZLWKZDWHU
± ,I \RX FDQQRW UHDFK \RXU JDV VXSSOLHU FDOO WKH )LUH DQGKDYHSXPSRSHUDWLQJ&KHFNWKDWZDWHUÀRZLV
'HSDUWPHQW XQREVWUXFWHG IURP WKH DSSOLDQFH :KHQ RSHUDWLQJ
IRUWKH¿UVWWLPHRUDIWHUDQH[WHQGHGVKXWGRZQUXQ
&8VHRQO\\RXUKDQGWRWXUQWKHJDVFRQWURORQRURII
¿OWHUSXPSIRUVHYHUDOPLQXWHVWRFOHDUDOODLUIURP
1HYHU XVH WRROV ,I \RX FDQQRW FKDQJH WKH 212))
WKHV\VWHP
VHWWLQJE\KDQGGRQ¶WWU\WRUHSDLULWFDOODTXDOL¿HG
VHUYLFHWHFKQLFLDQ)RUFHGRUDWWHPSWHGUHSDLUPD\UHVXOW
LQD¿UHRUH[SORVLRQ
''RQRWXVHWKLVKHDWHULIDQ\SDUWKDVEHHQXQGHUZDWHU
,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFW
WKHKHDWHUDQGWRUHSODFHDQ\SDUWRIWKHFRQWUROV\VWHP
DQGDQ\JDVFRQWUROZKLFKKDVEHHQXQGHUZDWHU
( 'RQRWRSHUDWHWKHSRROKHDWHUXQOHVVWKHSRRORUVSDLV
SURSHUO\¿OOHGZLWKZDWHU

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 4. Operation Instructions 33
OPERATING INSTRUCTIONS
 67235HDGWKHVDIHW\LQIRUPDWLRQRQ SDJH 
 6HWERWKSRRODQGVSDWKHUPRVWDWVWRWKHORZHVWVHWWLQJV Water
Pressure
 7XUQRIIDOOHOHFWULFSRZHUWRWKHDSSOLDQFH7XUQ2))WKH0DQXDO Switch

6KXW2II9DOYH DVVKRZQEHORZ 
 7KLVDSSOLDQFHGRHVQRWKDYHDSLORW,WLVHTXLSSHGZLWKDQLJQLWLRQ
GHYLFHZKLFKDXWRPDWLFDOO\OLJKWVWKHEXUQHU'RQRWWU\WROLJKWWKH
EXUQHUE\KDQG
 5HPRYHWKHDFFHVVGRRUSDQHOVE\XQIDVWHQLQJWKHWZR  VFUHZV
ORFDWHGRQHDFKGRRUWKHQOLIWXSDQGRXWIURPWKHERWWRPRIWKHSDQHO
WRUHPRYH,IQHFHVVDU\WKHVFUHZVPD\EHXVHGDVKDQGOHV
VHH)LJXUH
 7RJJOH6W\OH9DOYH3XOOWRJJOHWRZDUG\RXWRWXUQJDVRII
VHH)LJXUH
Figure 26.
 :DLW¿YH  PLQXWHVWRFOHDURXWDQ\JDV,I\RXWKHQVPHOOJDV
6723)ROORZ³%´LQWKH³%HIRUH6WDUWXS´LQVWUXFWLRQV SDJH 
,I\RXGRQ¶WVPHOOJDVJRWRWKHQH[WVWHS
 7XUQ21WKH0DQXDO6KXW2II9DOYH DVVKRZQEHORZ 7RJJOH6W\OH
9DOYH3XVKWKHWRJJOHVZLWFKDZD\IURP\RXWRVZLWFKWKHJDVRQ
 5HSODFHWKH'RRU$FFHVV3DQHOV$OOSDQHOVPXVWEHLQSODFHZKHQ
RSHUDWLQJWKHKHDWHU
 6HWZD\YDOYHVRQLQOHWDQGRXWOHWWRSRRORUVSDDVDSSURSULDWH
 7XUQRQDOOHOHFWULFSRZHUWRWKHDSSOLDQFH
 3UHVVHLWKHUWKH322/21RU63$21EXWWRQVZLWFKRQWKHRSHUDWLQJ
FRQWURO
 6HWWKHWKHUPRVWDWWRGHVLUHGVHWWLQJ NOTICE:6HWSRLQWPXVWEHDERYH
DFWXDOZDWHUWHPSHUDWXUHRUEXUQHUZLOOQRW¿UH 6HH³23(5$7,1*WKH
&21752/3$1(/´
 7KHEORZHUVKRXOGFRPHRQLPPHGLDWHO\DQGDIWHUDERXWVHFRQGVWKH
EXUQHUVKRXOG¿UH:KHQRSHUDWLQJIRUWKH¿UVWWLPHWKHEXUQHUPD\QRW
¿UHRQWKH¿UVWWU\EHFDXVHRIDLULQWKHJDVOLQH,ILWGRHVQRW¿UHDW¿UVW Gas control is shown OFF. Figure 27.
SXVKWKH2))VZLWFKZDLW¿YHPLQXWHVDQGDJDLQSXVKWKH322/RU Push toggle switch away
63$21VZLWFK7KHEXUQHUVKRXOG¿UHDIWHUDERXWVHFRQGV<RX from you to switch ON.
PD\KDYHWRUHSHDWWKLVXQWLODOORIWKHDLUKDVFOHDUHGWKHJDVOLQH
 7KHEXUQHUVKRXOG¿UHXQWLOWKHSRROVSDWHPSHUDWXUHUHDFKHVWKHGHVLUHG
WHPSHUDWXUHVHWRQWKHWKHUPRVWDW7KHEORZHUZLOOFRQWLQXHWRUXQIRUDERXWVHFRQGVDIWHUWKHEXUQHUVKXWV
RII,IDQ\RIWKHVDIHW\LQWHUORFNVVKRXOGRSHQGXULQJEXUQHURSHUDWLRQWKHEXUQHUVKXWVRIILPPHGLDWHO\EXWWKH
EORZHUFRQWLQXHVWRUXQIRUDERXWVHFRQGV6KRXOGRYHUKHDWLQJRFFXURUWKHJDVVXSSO\IDLOWRVKXWRIIWXUQRII
WKHPDQXDOJDVFRQWUROYDOYHWRWKHDSSOLDQFH
 ,IWKHDSSOLDQFHZLOOQRWRSHUDWHIROORZWKHLQVWUXFWLRQVEHORZ
³7278512))*$6727+($33/,$1&(´DQGFDOO\RXUVHUYLFH Manual
Shut-off
WHFKQLFLDQRUJDVVXSSOLHU Valve
TO TURN OFF GAS TO APPLIANCE
 3UHVVWKH2))EXWWRQRQRSHUDWLQJFRQWURO
 6ZLWFKRIIDOOHOHFWULFSRZHUWRWKHXQLW
7XUQ2))WKH0DQXDO6KXW2II9DOYH DVVKRZQRQULJKW
 5HPRYHWKHDFFHVVGRRUSDQHOVVHH)LJXUH
 7RJJOH6W\OH9DOYH3XOOWRJJOHWRZDUG\RXWRWXUQJDVRIIVHH)LJXUH
MANUAL SHUT-OFF VALVE LOCATION
 5HSODFHWKH$FFHVV'RRU3DQHOV
Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
Figure 29.
34 Section 4. Operation Instructions

SAFETY CONTROLS Figure 28.

AIR FLOW SWITCH (AFS)


7KHDLUÀRZVZLWFK VHH)LJXUH LVDVDIHW\GHYLFHXVHGWRLQVXUHWKDWWKHFRPEXVWLRQ
DLUEORZHU IDQ LVRSHUDWLQJDQGKDVEHHQGHVLJQHGWRPRQLWRUWKHYDFXXP QHJDWLYH 
SUHVVXUHZLWKLQWKHEORZHUKRXVLQJ7KHDLUÀRZVZLWFKLVIDFWRU\VHWDQGLVFRQQHFWHG
XSVWUHDPRIWKHLJQLWLRQPRGXOH7KHLJQLWLRQPRGXOHGRHVQRWRSHUDWHXQOHVVWKHDLU
SUHVVXUHVZLWFKDQGDOOVDIHW\VZLWFKHVDUHFORVHG

WATER PRESSURE SWITCH


Air Flow Switch
WARNING
Hazardous pressure. Do not bypass the Water Pressure Switch or render
Figure 29.
it inoperable.
Water
7KHZDWHUSUHVVXUHVZLWFK VHH)LJXUH ,IWKHZDWHUÀRZLVUHVWULFWHGWKH Pressure
Switch

ZDWHUSUHVVXUHVZLWFKPD\SUHYHQWWKHEXUQHUIURP¿ULQJDQGFDXVHWKH³6HUYLFH
6\VWHP´OLJKWWRJRRQ,IWKHOLJKWUHPDLQVRQDIWHUWKH¿OWHUKDVEHHQVHUYLFHG
KDYHDTXDOL¿HGVHUYLFHWHFKQLFLDQFKHFNWKHV\VWHP
)RUGHFNOHYHOKHDWHULQVWDOODWLRQVWKH:DWHU3UHVVXUH6ZLWFKLVIDFWRU\VHWDW
SVL N3D NOTE: See, Below Pool Level Installation instructions on
page 13,IWKHSUHVVXUHVZLWFKLVRQHIHHW 0 EHORZRUDERYHWKHSRROZDWHU
OHYHOUHVHWWKHVZLWFKVRWKDWLWLVRSHQZKHQWKHSXPSLVRIIDQGFORVHGZKHQ
WKHSXPSLVUXQQLQJ7XUQWKHVWDUZKHHORQWKHVZLWFKFORFNZLVH  WR
UDLVHVHWWLQJ KHDWHUEHORZWKHSRRO DQGFRXQWHUFORFNZLVH  WRORZHUWKH
VHWWLQJ KHDWHUDERYHWKHSRRO±VHH)LJXUH7HVWWKHVZLWFKDIWHUUHVHWWLQJ
NOTICE::KHQWKHKHDWHULVPRXQWHGPRUHWKDQ¿YHIHHW 0 DERYH
RUIRXUIHHW 0 EHORZWKHGHFNOHYHOD3UHVVXUH
6ZLWFKLVQRORQJHUDGHTXDWH$)ORZ6ZLWFKPXVWEH Turn star wheel clockwise to raise
pressure set point if pressure switch is
LQVWDOOHGLQVWHDG more than 4 feet (1.2M) below water level
NOTICE:+HDWHURSHUDWLRQZLWKLQFRUUHFW3UHVVXUH
6ZLWFKVHWWLQJPD\FDXVHRSHUDWLRQZLWKQRZDWHUÀRZ
2SHUDWLRQRIWKHKHDWHUZLWKRXWVXI¿FLHQWZDWHUÀRZ
PD\VHYHUHO\GDPDJHLW
Star Wheel
HIGH LIMITS
$ ³+LJK /LPLW´ LV D VDIHW\ GHYLFH WKDW RSHQV WKH
HOHFWULFDOFLUFXLWDQGVKXWVRIIWKHKHDWHUEDVHGRQDZDWHU
WHPSHUDWXUH VHW SRLQW ZLWKLQ WKH ³+LJK /LPLW 'HYLFH´ A reference scale is on
7KH0DVWHU7HPS®KHDWHUFRQWDLQVWZR  KLJKOLPLW the back of pressure switch
GHYLFHVZKLFKDUHORFDWHGRQWKHPDLQLQOHWRXWOHWKHDGHU

Turn star wheel counterclockwise to lower


pressure set point if pressure switch is more
than 5 feet (1.5M) above water level
Figure 30.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 4. Operation Instructions 35

SAFETY CONTROLS (continued) Flame Current Diagnostic LED


Check Point 1 Flash - Air Flow Fault
OPERATION OF IGNITION MODULE 2 Flashes - Flame No Call for Heat
3 Flashes - Ignition Lockout
7KH,JQLWLRQ0RGXOH VHH)LJXUH LVPLFURSURFHVVRUEDVHGDQG
RSHUDWHVRQ9$&VXSSOLHGE\WKHWUDQVIRUPHU7KHFRQWUROXWLOL]HV
DPLFURSURFHVVRUWRFRQWLQXDOO\DQGVDIHO\PRQLWRUDQDO\]HDQG
FRQWUROWKHSURSHURSHUDWLRQRIWKHJDVÀDPHKROGHU7KHPRGXOH
ZLWKWKHSUHVHQFHRIWKHÀDPHVHQVRUXVLQJÀDPHUHFWL¿FDWLRQ
DOORZVWKHKHDWHUWRRSHUDWH

OPERATING THE CONTROL PANEL Figure 31.


7KH¿YHRSHUDWLQJVZLWFKHVDUH VHH)LJXUH Temperature Digital Temperature
Up and Down Display

POOL ON 3UHVVWKLVEXWWRQWRJRYHUQKHDWHURSHUDWLRQE\WKH


 SRROWHPSHUDWXUHVHWWLQJ
SPA ON 3UHVVWKLVEXWWRQWRJRYHUQKHDWHURSHUDWLRQE\WKH
 VSDWHPSHUDWXUHVHWWLQJ
HEATER OFF 3UHVVWKLVEXWWRQWRVZLWFKRIIWKHKHDWHU
▲ TEMP 3UHVVWKLVEXWWRQWRUDLVHWKHWHPSHUDWXUHVHWWLQJ
▼ TEMP 3UHVVWKLVEXWWRQWRORZHUWKHWHPSHUDWXUHVHWWLQJ
System Operation Dual Temperature Heater "OFF"
7RWRJJOHWKHGLVSOD\EHWZHHQGHJUHHV&HQWLJUDGH ƒ& DQGGHJUHHV Indicator Lights Controls Switch

)DKUHQKHLW ƒ) 
 7XUQWKH2SHUDWLQJ&RQWURO2))
Figure 32.
 3UHVV▲TEMPRU▼TEMPIRUVHFRQGV7KHGLVSOD\ZLOOÀDVKRQFHDQGFKDQJHPRGHV ƒ&WRƒ)RUYLFHYHUVD 
 7XUQWKH2SHUDWLQJ&RQWURO21
:KHQHLWKHUWKH▲TEMPRU▼TEMPEXWWRQVDUHGHSUHVVHGWKHGLJLWDOGLVSOD\ZLOOLQGLFDWHWKHWHPSHUDWXUHVHWWLQJ
$IWHU¿YHVHFRQGVWKHGLVSOD\ZLOOUHWXUQWRWKHDFWXDOSRROVSDWHPSHUDWXUH
,QDGGLWLRQWRWKHGLJLWDOWHPSHUDWXUHGLVSOD\WKHUHDUH¿YHLQGLFDWRUOLJKWV
7KHPOOL ONOLJKWLQGLFDWHVWKDWWKHSRROZDWHUWHPSHUDWXUHLVJRYHUQLQJRSHUDWLRQRIWKHKHDWHU
7KHSPA ONOLJKWLQGLFDWHVWKDWWKHVSDZDWHUWHPSHUDWXUHLVJRYHUQLQJRSHUDWLRQRIWKHKHDWHU
7KHHEATINGOLJKWFRPHVRQDQGVWD\VRQZKHQWKHEXUQHULV¿ULQJ7KLVOLJKWVKRXOGEHRQZKHQHYHUWKHEXUQHULV
RQ,WEOLQNVZKHQWKHKHDWHULVFDOOLQJIRUKHDWEXWQRW¿ULQJ,IWKLVOLJKWLVRQEXWWKHEXUQHUIDLOVWRFRPHRQRQHRIWKH
³VHUYLFH´OLJKWVVKRXOGFRPHRQLQGLFDWLQJDIDXOWLQWKHV\VWHP
7KHSERVICE SYSTEMOLJKWLQGLFDWHVWKDWWKHUHLVLQVXI¿FLHQWZDWHUÀRZWRWKHKHDWHU,IWKHSXPSLVRSHUDWLQJWKLV
XVXDOO\LQGLFDWHVWKDWWKH¿OWHUDQGRUVNLPPHUVVKRXOGEHFOHDQHG VRPH¿OWHUVPD\UHTXLUHEDFNZDVKLQJ ,IWKHOLJKW
UHPDLQVRQDIWHUWKH¿OWHUVNLPPHUVKDYHEHHQVHUYLFHGWKHV\VWHPVKRXOGEHFKHFNHGE\DTXDOL¿HGVHUYLFHWHFKQLFLDQ
7KHSERVICE HEATEROLJKWLQGLFDWHVDIDXOWLQWKHKHDWHURULWVFRQWUROV,IWKLVOLJKWFRPHVRQVKXWGRZQWKHKHDWHU
6HH³7278512))*$6727+($33/,$1&(´RQSDJH DQGKDYHDTXDOL¿HGVHUYLFHWHFKQLFLDQFKHFNWKHV\VWHP

WARNING
Risk of explosion or fire causing burns or death if safety interlocks are disabled. DO NOT attempt to operate heater when
SERVICE HEATER light is on or if blower or burner will not start. Instead, follow instructions under “To Switch Off Gas to the
Appliance,” and call a qualified service technician to repair unit.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
36 Section 4. Operation Instructions

TEMPERATURE SETTING

7KHKHDWHUFRPHVIDFWRU\VHWDWƒ)IRUWKHSRROPRGHDQGƒ)IRUWKHVSDPRGH8VLQJWKHXSDQGGRZQDUURZV
\RXFDQVHWWKHWKHUPRVWDWVWRDPLQLPXPWHPSHUDWXUHRIƒ)RUDPD[LPXPRIƒ),I\RXGHVLUHWRKHDWRQO\RQH
ERG\RIZDWHUWKHWKHUPRVWDWLVFDSDEOHRIDQRIIPRGH$VDQH[DPSOHLI\RXRQO\ZLVKWRKHDWWKHVSDDQGQRWWKHSRRO
VLPSO\GHSUHVVDQGKROGWKHSRROGRZQDUURZDQGWKHWKHUPRVWDWZLOOORZHULWVVHWWLQJWRƒ)WKHQJRWRDQRIIPRGH

MAXIMUM TEMPERATURE SET POINT

 8QEROWDQGUHPRYHWKHGRRUSDQHOV VHH)LJXUH 


 $FFHVVWKHFRQWUROSDQHOERDUGRQWKHXQGHUVLGHRIWKHWRSFRYHU/RFDWHWKH\HOORZEXWWRQRQWKHFRUQHURIWKH
FRQWUROERDUG
 3XVKWKHMax. Temp. Set PointEXWWRQRQWKHEDFNRIWKHFRQWUROERDUG VHH)LJXUH 
7KHIROORZLQJVHTXHQFHVKRXOGKDSSHQ
 $ 7KHXQLWZLOOFRPHRQDQGWKHPOOL ONOLJKWZLOOFRPHRQ
 % 3UHVVWKH▲TEMPRU▼TEMPSDG RQ723RIWKHSDQHO WRVHWPD[LPXPSRROWHPSHUDWXUH
 & :DLWXSWRVHFRQGVWKHPOOL ONOLJKWZLOOJRRIIDQGWKH SPA ONOLJKWZLOOFRPHRQ7RRYHUULGHWKH
 WLPHGHOD\SXVKWKH Max. Temp. Set PointEXWWRQDJDLQ
 ' 3UHVVWKH▲TEMPRU▼TEMPEXWWRQRQWKHFRQWUROSDQHODQGVHWPD[LPXPVSDWHPSHUDWXUHWRƒ) 
 ƒ& RUOHVV
 ( :DLWXSWRVHFRQGVWKHSPA ONOLJKWZLOOJRRIIDQGWKHXQLWZLOOVKXWGRZQ7RRYHUULGHWKHWLPHGHOD\
 SUHVVWKHMax. Temp. Set PointEXWWRQDJDLQ
 5HLQVWDOOWKHDFFHVVGRRUSDQHOV

Top Panel
Door Acess Panel
S AX
E

S1
M
T

Door Acess Panel


S AX

S1
E
M
T

Figure 33. Figure 34.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 5. Troubleshooting 37

Troubleshooting Instruction

Initial Troubleshooting
Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember
that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure that
the pump is running correctly, that there are no blockages in the system, that the valves are correctly set and that
the time clock is correctly set and is running.

IMPORTANT! READ ME FIRST!


NOTICE: Installing the black 120 volt plug in the control box and on either 120 Volts AC or 240 Volts AC.
then connecting the heater to a 240 volt line will destroy the trans - 2. Remove the covers and check the 12-pin plug in the back of the
former, control broad, and ignition control module, and will void the control box. The plug must match the voltage in the heater circuit.
warranty. If you install the red 240 volt plug and then connect the
heater to a 120 volt line, the heater will not operate. 3. If the 12-pin plug is not plugged into the back of the control
box, select the correct plug from the bag in the control box
READ THE FOLLOWING CAREFULLY: and plug it in. The BLACK plug is for 120 volts, the RED plug
1. Check the line voltage to your heater. This heater will operate is for 240 volts.

Start here for directions to specific Troubleshooting Chart

NO Go to chart “HEATER WILL


Is green “POOL” or “SPA”
NOT FIRE - A”
LED “on”?
(Page 38)

YES

YES Go to chart “HEATER WILL


Is red “SERVICE SYSTEM”
NOT FIRE - B”
LED “on”?
(Page 39)
NO
Are any red diagnos-
YES tic LED’s on back of YES Go to specific safety switch
Is red “SERVICE HEATER”
board (AGS, AFS, troubleshooting chart
LED “on”?
SFS, HLS, PS or (Pages 41 and 42)
THERMISTOR) “on”
NO
NO
Turn off power to heater for
about 5 seconds, and turn
back on. Make sure tempera-
ture setting is above water
temperature. Wait one minute.
Do any diagnostic LED’s on YES
back of board (AGS, AFS,
SFS, HLS, PS, or
THERMISTOR) come “on”
NO Does red “SERVICE YES Go to chart ‘HEATER WILL
and stay on?
HEATER” LED come NOT FIRE -C”
NOTICE: Any or all of the diag- “on” (Page 40)
nostic LED’s may come “on”
momentarily when you turn on
the power to the heater. NO

Verify that water temperature setting is


above water temperature reading. If it is,
and heater either will not fire or no red
LED’s come “on”, replace Control Board.

WARNING Hazardous voltage. Can shock, burn or kill. WARNING Fire and Explosion hazard. Do not jumper
Disconnect power before servicing any components. switch terminals to remedy a failed safety switch.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
38 Section 5. Troubleshooting

Heater Will Not Fire - A


Start
NO Depress “POOL” or “SPA” ON YES Heater should fire on demand
Is green “SPA” or
button on Membrane Pad. for heat.
“POOL” LED “on”
Does “POOL” or “SPA” LED
YES come on?
NO
Check that correct 12-pin YES Check for line voltage to NO
plug is installed (red is Restore power to heater.
heater.
240V, black is 120V)
YES
NO
Check for 24 VAC at sec-
If plug is not installed:
Install correct plug. YES ondary of Transformer. Check wiring connections
NO between power supply and
240V plug in 120V Junction Box and between
circuit: Replace with NO Junction Box and Terminal
correct plug. Check for Line Voltage
between L1 and L2 terminals Board; restore continuity.
120V plug in 240V
circuit: Replace trans- on Terminal Board.
former, control board, Check wiring connections
YES
and ignition control between Terminal Board and
module (see “HEATER Check for Line Voltage at NO Transformer primary and
WILL NOT FIRE-C and Transformer primary pins. restore continuity.
-D”, Pages 40 and 41). White connects to Pin 3 on
Check fuse and all Transformer, Black to Pin 2,
other 24V components Orange to Pin 1. YES Replace Transformer.
for damage. 240V: check Pin1 to Pin 3.
120V: check Pin 2 to Pin 3.

Jumper Fireman’s Switch at YES Check Fireman’s Switch circuit


Terminal Board and depress connections (time clock, wiring,
“POOL” or “SPA” ON button on external controller relay).
membrane pad. Does “SPA” or
“POOL” LED come “on”?
NO
Remove jumper. Check wiring
YES Leaving jumper in place, NO between Transformer and J7
check for 24 VAC between
terminals on Control Board
Fireman’s Switch terminals
and between J7 and
and ground.
Fireman’s Switch on Terminal
Board, check fuse, and
Remove jumper. Check ribbon restore continuity.
cable connection between
Membrane Pad and J6 on
Control Board. Depress YES Heater should fire on
“POOL” or “SPA” On pad demand for heat.
NO again. Does “POOL” or “SPA”
LED come on?
YES Replace Membrane Pad.
Jumper pins 6 and 5 on J6 of
Control Board. Does “SPA”
LED come on? NO
Jumper pins 6 and 4 on J6 of Replace Control Board.
Control Board. Does “POOL”
LED come on?
GO TO
“HEATER WILL NOT FIRE - B”
Page 39

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 5. Troubleshooting 39

Heater Will Not Fire - B


Start
Is red “SERVICE NO Is red “SERVICE SYSTEM” NO Increase POOL/SPA tempera-
HEATER” LED “on” LED on? ture setting on Membrane
Pad above actual water tem-
YES perature. Heater should fire
YES on demand for heat. If not,
Verify that pump is on, filter is and no other red LED’s light,
not blocked, and the water NO replace Control Board.
flow is above the minimum
requirement.
YES Service pump/filter and elimi-
With pump running, adjust nate other flow obstructions.
Water Pressure Switch to
lower pressure until ‘SER-
VICE SYSTEM” LED goes YES
out. Then verify that “SER- Heater should fire on call for
VICE SYSTEM” LED goes on heat. Re-verify that water flow
with pump off. is above minimum require-
ment.
NO
Minimum Flow Requirements
Check that water pressure is NO
within the adjustment range of Model Flow
the Pressure Switch (0-5 psig) 175 20 gal/min (76 LPM)
200 20 gal/min (76 LPM)
YES 250 25 gal/min (95 LPM)
300 30 gal/min (114 LPM)
Verify that switch wiring is OK 400 40 gal/min (151 LPM)
CONTINUE and Pressure Switch port is
not blocked, and replace
water Pressure Switch. If water pressure is outside of
adjustment range that will
open switch with pump off
and close switch with pump
on, replace with flow switch
set above minimum flow
requirement.
Minimum Flow Requirements
Model Flow
175 20 gal/min (76 LPM)
200 20 gal/min (76 LPM)
250 25 gal/min (95 LPM)
300 30 gal/min (114 LPM)
400 40 gal/min (151 LPM)

Check whether any of the


red diagnostic LED’s on back YES Go to “Diagnostic LED’s”,
of board (AGS, AFS, SFS, (Pages 42 and 43)
HLS or PS) are “on”

NO

GO TO
“HEATER WILL NOT FIRE - C”
Page 40

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
40 Section 5. Troubleshooting

Heater Will Not Fire - C


Start
Is “SERVICE HEATER” LED NO Go to “INITIAL
“on”? TROUBLESHOOTING”

YES Turn off power to


heater for 5 seconds, Continue to observe heater
and turn back on. for several minutes. Cycle
Make sure tempera- heater on and off several
ture setting is above times. Observe for delayed or
If any red diagnostic LED’s NO water temperature. YES rough ignition, poor combus-
(AGS, AFS, SFS, HLS, PS, or Wait one minute. tion, premature extinction of
THERMISTOR) come “on”, go flame, evidence of boiling, or
to to Pages 42 and 43. Does heater fire and
stay on? operation of any diagnostic
LED. Go to pertinent trou-
bleshooting section if any
malfunction is observed.
CONTINUE
NO NO
Did burner fire at all? Did Blower come on? Replace Control Board.
YES YES
Verify that gas is flow- NO Verify that gas supply is open
Go to “BURNER
TROUBLESHOOTING” ing to burner during all the way to Gas Valve, and
(Page 44) ignition try. Observe Gas Valve is set at “on”
gas meter for move- position.
ment during ignition Check for 24 VAC to Gas
YES try (wait for about 30 NO Valve terminals during ignition
Go to “HEATER WILL NOT try. (Voltage appears about 24
seconds after calling
FIRE-D” (Page 41) seconds after call for heat).
for heat).
SEE NOTE 2.
YES
Replace Ignition Control Check for 24 VAC
Module. YES between TH and GND Replace Gas Valve with
terminals on Ignition identical part.
NO Control Module.
SEE NOTE 1.
Check for 24 VAC between
VAL and GND terminals on NO Fix wiring between TH and
YES
Ignition Control Module. GND terminals of Ignition
SEE NOTE 2. Check for 24 VAC Control Module and Control
between TH and GND Board.
YES terminals on Control NO
Check for 24 VAC between Board. SEE NOTE 1.
YES Replace Control Board.
VAL and GND terminals on
Control Board. SEE NOTE 2.
Check for 24 VAC
NO YES Fix wiring between GAS ter-
between GAS termi-
Fix wiring between VAL and minals on Control Board and
nals on Control
GND terminals of Ignition Gas Valve.
Board. SEE NOTE 2.
Control Module and Control
Board. NO
NOTE 1: Voltage appears immedi-
Replace Control ately after call for heat, and may be
Board. on for only about 30 seconds.
NOTE 2: Voltage appears about 24
seconds after call for heat, and may
be on for only about 7 seconds.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 5. Troubleshooting 41

Heater Will Not Fire - D

IMPORTANT! READ ME FIRST!


IMPORTANT! READ ME FIRST!!
If your heater is correctly connected to 240 Volts AC, the meter will read either 0 VAC or 240 VAC. If your ICM is
Ignition Control Module (ICM) will convert the 240VAC to good, your meter will read some voltage between 0 and
an intermittent pulse to the ignitor. Digital meters don’t read 240 VAC. Exactly what reading you get will depend on the
this type of signal well. (An analog meter will give a better meter, but with a good ICM, the reading won’t be 0 VAC or
reading than a digital meter). If the ICM is bad, your volt- 240 VAC, but somewhere in between.

Start
Gas flows during igni- NO Go back to chart “HEATER WILL
tion try, but burner
NOT FIRE-C” (Page 40).
does not fire.
YES

Check voltage across YES YES


Check gas pressure. OK?. Replace HSI Igniter.
igniter leads; OK?

NO NO

Replace Ignition Increase gas flow into heater:


Control Module. On a : Replace gas line with larger
120 V installation, line;
check the ignitor for : Replace regulator;
damage if it has seen : Replace meter; or
240 VAC. : All of the above.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
42 Section 5. Troubleshooting

Diagnostic LED's: AGS, AFS, HLS, PS, THERMISTOR


Verify that water flow rate is NO Service pump and filter to
AGS or HLS "on" above minimum required for restore proper flow. After ser-
heater. vicing, verify proper operation
Replace High Limit of Pressure Switch (PS).
Switch (HLS) or YES
Automatic Gas YES Verify that inlet water temper- NO
Shutoff (AGS) ature is below 104˚ F.
Replace thermistor or Control
CONTINUE Board to correct overheating.
If problem persists, verify proper operation of Internal Bypass Valve
and Thermal Governor, and check for Heat Exchanger blockage.

Verify that water flow rate is Service pump and filter to


PS "on" above minimum required for
NO
restore proper flow.
heater.
Verify that wiring is CONTINUE
OK and pressure tap YES
is not blocked. Re- CONTINUE Adjust Water Pressure Switch to close with pump running and open with
place Pressure Switch pump off.

Does Blower operate? YES Verify that there is no block-


AFS "on"
age in Blower intake, Heat
NO Exchanger, and exhaust and
Disconnect Blower and check that exhaust is not too long
YES (see “Indoor Vent Installation”,
Replace Blower. for line voltage between pins
1 and 3 of Blower Connector Page 23.
on ignition try. Verify correct connection of
Verify that wires BM NO wiring and that pressure taps
and F1 are correctly to AFS are OK.
connected at the YES Check for 24 VAC between
Verify that vinyl tubing to AFS
terminal strip (see 24 VAC and GND terminals
and Blower is not misrouted,
Heater Connection on Ignition Control Module on
kinked, disconnected, or
Diagram, Page 30). ignition try. Check that IND
NO punctured.
wire is correctly connected.
Replace Air Flow Switch
NO (AFS).
Verify correct If problem persists, replace
connection of wiring between Blower.
YES 24 VAC and IND terminals on
Ignition Control Module and
Control Board, and replace
Control Board.

Connect correctly and retry.


Disconnect wires F1 NO Does Blower start?
and F2 from Ignition
Control Module and NO
short them together. Replace Blower. Does Blower
Does Blower come NO start on ignition try?
on?
Replace Ignition Control
YES
Module.

Verify Thermistor wiring. If


THERMISTOR "on" OK, replace Thermistor.

CAUTION Do not jumper a safety switch to NOTE: ES1 is a spare and should be jumpered.
remedy a failed switch.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 5. Troubleshooting 43

Diagnostic LED's: SFS


SFS "on"
Check Heat Exchanger NO
Coil for leaks, liming, soot,
or low flow.
Heater starts and runs OK,
YES
but temperature of exhaust
climbs to 450˚–500˚ in 3–5 YES Check Thermal
minutes. Regulator: Open at
120˚?
NO YES NO Replace Heater
NO (HD ) Membrane Pad.
Heater starts after several Correct problem;
DONE
tries, exhaust temperature Heater should fire.
stays below 250˚.
NO
OR
Heater doesn’t start at all YES
(exhaust stays cold). Check Thermal-Regulator:
Seats correctly?
Replace Heater
Control Board.
Check pressure and volume
of fuel supply NOT OK
DONE
OK Correct Fuel Supply, reset
Heater and retry. Heater
Disconnect the sensor and should fire correctly.
check continuity across its
terminals. Resistance NO
should be 3.5-4.0 mega-
ohms. NO Reset power to Heater and
= open circuit; Replace Stack Flue Sensor retry. Heater should fire.
0 = shorted. DONE
Does sensor check OK?
NO
Reset power to Heater and
YES retry. Heater should fire. Check Heat Exchanger Coil for
Check continuity in wiring leaks, liming, soot, or low flow.
NO
harness between Control
YES Board and Probe.
Continuity OK?
Repeat checks on fuel Replace Heater Control Board.
NO supply, Thermal Regulator,
check for correct orifices, DONE
Check the J3 and J6 etc.
Reset power to Heater and
connectors for corrosion/ YES retry. Heater should fire.
looseness on the male
pins. NO NO
Does the Digital
Temperature Display show NO
YES Error Code “E05” or “E06”? Replace Heater Membrane Pad.
(Basic)
Clean/tighten pins as DONE
needed.
DONE Reset power to Heater and
retry. Heater should fire.
Reset power to Heater NO
and retry. Heater should
fire.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
44 Section 5. Troubleshooting

Burner Troubleshooting
SYMPTOM CAUSE REMEDY
Loud, high-pitched whine Flame is too rich. Verify pressure tap between gas valve
and blower inlet.
See page 16 and verify that the gas
regulator setting is –0.2" (–0.5cm) wc.
Contact a qualified technician or service
agency to replace the gas orifice.

Flame is “fluttery .” Flame is too lean. See page 16 and verify that the gas
Exhaust may have acrid regulator setting is –0.2" (–0.5cm) wc.
smell or burner may fail
Contact a qualified technician or service
to stay lit.
agency to replace the gas orifice.

Burner pulsates or Exhaust vent is too long. Reduce length of exhaust vent and/or
surges, especially on number of elbows.
ignition.
Combustion appears Flame current is not Check for wet or damaged igniter with
normal, but flame does being sensed. low resistance to ground. Replacewith
not stay lit. new igniter.
Verify burner flameholder is properly
grounded.
Replace Ignition Control Module.

Heat Exchanger Troubleshooting


SYMPTOM CAUSE REMEDY
Boiling in heat exchanger. Low water flow to heater. Service pump and or filter.
May be accompanied by Heat exchanger plugged. Service heat exchanger. Correct water
“bumping” sounds.
chemistry.
Bypass valve stuck open. Service bypass valve.
Thermal governor stuck Replace thermal governor.
closed.
Sweating. Thermal governor failed. Replace thermal governor.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 6. Maintenance 45

Maintenance Instructions

CARE AND MAINTENANCE

WARNING
Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile
flammable liquids near heater or in the same room with heater.
7KHIROORZLQJPDLQWHQDQFHLVUHFRPPHQGHGHYHU\VL[PRQWKVDQGDWWKHVWDUWRIHYHU\VZLPPLQJVHDVRQ
 ,QVSHFWWKHKHDWHUSDQHOVDQGYHQWLQJV\VWHPWRPDNHVXUHWKDWWKHUHDUHQRREVWUXFWLRQVWRWKHÀRZRIYHQWLODWLQJDLU
RUEXUQHUH[KDXVW&KHFNWKDWURRPDLULQWDNHVDUHRSHQDQGFOHDURIREVWUXFWLRQV
 .HHSWKHDUHDLQDQGDURXQGWKHKHDWHUFOHDUDQGIUHHIURPFRPEXVWLEOHPDWHULDOVJDVROLQHDQGRWKHUÀDPPDEOH
YDSRUVDQGFRUURVLYHOLTXLGV
 7HVWWKHRSHUDWLRQRIWKHSUHVVXUHUHOLHIYDOYHE\OLIWLQJWKHYDOYHOHYHU LILQVWDOOHG 
 7HVWIRUSURSHURSHUDWLRQRIWKHZDWHUSUHVVXUHVZLWFK 6HH³:$7(535(6685(6:,7&+´ SDJH IRUWHVWLQJ
LQVWUXFWLRQV 
 2QHQFORVHGLQVWDOODWLRQVZLWKKLJKWHPSHUDWXUH6SHFLDO*DV9HQWV\VWHPVUHSHDWWKH³)LQDO,QVWDOODWLRQ&KHFN´SDJH
&KHFNIRUHYLGHQFHRIMRLQWOHDNDJH0DNHVXUHWKDWMRLQWVKDYHQRWVOLSSHGSDUWLDOO\RUFRPSOHWHO\DSDUW&KHFN
SLSHDQG¿WWLQJVIRUFUDFNVRUEUHDNV7KHFRPEXVWLRQDLUEORZHULVSHUPDQHQWO\OXEULFDWHGDQGGRHVQRWUHTXLUH
SHULRGLFOXEULFDWLRQ7KHEXUQHUGRHVQRWUHTXLUHPDLQWHQDQFHRUDGMXVWPHQWE\WKHXVHU&DOODTXDOL¿HGVHUYLFH
WHFKQLFLDQLI\RXVXVSHFWWKDWWKHEXUQHUPD\UHTXLUHPDLQWHQDQFH

WARNING
Explosion hazard. Any heater installed with restrictive devices in the piping system downstream from the heater, (including
check valves, isolation valves, flow nozzles, or therapeutic pool valving), must have a relief valve installed as described above.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
46 Section 6. Maintenance

AFTER START-UP
CHECKING WATER FLOW
WARNING
Fire or flooding hazard. If the unit overheats and the burner fails to shut off, follow instructions under “To Turn Off Gas to the
Appliance”, page 33, and call a qualified service technician to repair unit.
$IWHUVWDUWXSWKHRXWOHWZDWHUSLSHVKRXOGIHHOVOLJKWO\ZDUPHUWKDQWKHLQOHWSLSH,ILWIHHOVKRWRULI\RXKHDUWKHZDWHULQWKHKHDWHU
ERLOLQJWKHUHPD\QRWEHHQRXJKZDWHUÀRZWRWKHDSSOLDQFH0DNHVXUHWKDWWKH¿OWHULVQRWSOXJJHG,IZDWHUWHPSHUDWXUHUHPDLQV
KLJKEXWWKHXQLWFRQWLQXHVWRRSHUDWHWXUQRIIWKHDSSOLDQFHDQGFDOO\RXUVHUYLFHWHFKQLFLDQ

SPRING AND FALL OPERATION


,IWKHSRROLVRQO\XVHGRFFDVLRQDOO\ORZHUWKHSRROWKHUPRVWDWWRƒ) ƒ& DQGOHDYHWKHKHDWHURQ7KLVZLOONHHSWKHSRRODQG
WKHVXUURXQGLQJJURXQGZDUPHQRXJKVRWKDWWKHKHDWHUVKRXOGUHVWRUHWKHSRROWRDFRPIRUWDEOHWHPSHUDWXUHZLWKLQDERXWRQHGD\

WINTER OPERATION
CAUTION
s /PERATINGTHISHEATERCONTINUOUSLYATWATERTEMPERATURESBELOW½F. (20° C) will cause harmful condensation and will
damage the heater and void the warranty.
s )FTHEHEATERHASBEENDRAINEDFORFREEZINGCONDITION DO./4TURNh/.vUNTILTHESYSTEMISCIRCULATINGWATER
s Water trapped in the heat exchanger can result in freeze damage to the exchanger or headers. Freeze damage is specifically
not covered by the warranty.
s 7HENSTARTINGTHEHEATERFORTHESWIMMINGSEASONWITHAWATERTEMPERATUREBELOW½&½# THEHEATERMAYBEUSED
to heat the water; however, make sure that the heater operates continuously until the water temperature reaches the
heater’s minimum setting of 68° F (20° C). During cold weather, if there is no danger of freezing, operate the filter pump
continuously even if the heater is not operating. If air temperatures are expected to drop below freezing (32° F/0° C), shut
down the heater and winterize it.

)RURXWGRRUKHDWHUVLQIUHH]LQJFOLPDWHVVKXWWKHKHDWHUGRZQDQGGUDLQLWIRUZLQWHUDVIROORZV
 7XUQRIIHOHFWULFDOVXSSO\WRWKHKHDWHUDQGSXPS
 &ORVHPDLQJDVFRQWUROYDOYHDQGPDQXDOJDVYDOYH ORFDWHGRXWVLGHWKHKHDWHU 7XUQVZLWFKRQKHDWHUJDVYDOYHWR2))
 'LVFRQQHFWWKH,1/(7DQG287/(7XQLRQVIURPWKHV\VWHPSOXPELQJDQGGUDLQWKHKHDWH[FKDQJHUDQGPDQLIROGDGDSWHUFRPSOHWHO\

,IWKHKHDWHULVEHORZSRROZDWHUOHYHOEHVXUHWRFORVHLVRODWLRQYDOYHVWRSUHYHQWGUDLQLQJWKHSRRO LVRODWLRQYDOYHVDUHQRWUHTXLUHG
DQGVKRXOGQRWEHXVHGRQKHDWHUVLQVWDOOHGDERYHSRROZDWHUOHYHOH[FHSWZKHQQHHGHGIRUZLQWHUL]LQJYDOYHV $VVLVWWKHGUDLQLQJ
E\EORZLQJRXWWKHKHDWH[FKDQJHUWKURXJKWKHSUHVVXUHVZLWFK¿WWLQJZLWKORZSUHVVXUHFRPSUHVVHGDLU OHVVWKDQ36,RUN3D 

WARNING
Explosion hazard. Purging the system with compressed air can cause components to explode, with risk of severe injury or death
to anyone nearby. Use only a low pressure (below 5 PSI or 35 kPa), high volume blower when air purging the heater, pump,
filter, or piping.
 5HPRYHWKH:DWHU3UHVVXUH6ZLWFK3OXJWKHSRUWLQWKHPDQLIROGWRSUHYHQWEXJVDQGGLUWIURPJHWWLQJLQWRWKHPDQLIROG
 'UDLQWKHSODVWLFLQOHWRXWOHWPDQLIROGWKURXJKWKHRXWOHWSLSH,IWKHSLSHGRHVQRWGUDLQQDWXUDOO\WRWKHSRROLQVWDOODGUDLQFRFN
LQWKHRXWOHWSLSHWRGUDLQWKHPDQLIROG
 &RYHUDLULQOHWJUDWHZLWKDSODVWLFEDJWRSUHYHQWEXJVOHDYHVHWFIURPJHWWLQJLQWRWKHKHDWHU
NOTICE:Water trapped in the heater can cause freeze damage. Allowing the heater to freeze voids the warranty.
7RUHWXUQWKHKHDWHUWRVHUYLFHDIWHUZLQWHUL]LQJ
 &RQQHFWWKH,1/(7DQG287/(7XQLRQVWRWKHV\VWHPSOXPELQJ&KHFNWKDWWKH\DUHFRQQHFWHGFRUUHFWO\DQGWKHUHDUHQRZDWHU
OHDNV
 %HIRUHVWDUWLQJWKHKHDWHUFLUFXODWHZDWHUWKURXJKWKHKHDWHUIRUVHYHUDOPLQXWHVXQWLODOODLUQRLVHVVWRS6HHDOVR³%()25(
67$5783´ SDJH DQG³&$5($1'0$,17(1$1&(´ SDJH 
(See additional notes under Important Notices in Introduction.)
MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 6. Maintenance 47

MAINTAINING POOL TEMPERATURE


7RPDLQWDLQSRROWHPSHUDWXUHPDNHVXUHWKDWWKHKHDWHUVZLWFKDQGYDOYHVDUHUHVHWWRSRROVHWWLQJVDIWHUXVLQJWKHVSD

ENERGY SAVING TIPS


 .HHSWKHSRRORUVSDFRYHUHGZKHQQRWLQXVH7KLVZLOOUHGXFHKHDWLQJFRVWVUHGXFHZDWHUHYDSRUDWLRQFRQVHUYH
FKHPLFDOVDQGUHGXFHORDGRQWKH¿OWHULQJV\VWHP
 5HGXFHSRROWKHUPRVWDWWRƒ) ƒ& RUORZHUUHGXFHVSDWHPSHUDWXUHWRƒ) ƒ& 7KLVLVDFFHSWHGDV
EHLQJWKHPRVWKHDOWK\WHPSHUDWXUHIRUVZLPPLQJE\WKH$PHULFDQ5HG&URVV
 8VHDWLPHFORFNWRVWDUWWKH¿OWHUSXPSDWDPRUODWHU7KHVZLPPLQJSRROORVHVOHVVKHDWDIWHUGD\EUHDN
 )RUSRROVXVHGRQO\RQZHHNHQGVORZHUWKHWKHUPRVWDWVHWWLQJE\ƒ)WRƒ) ƒ&WRƒ& GXULQJWKHZHHNWR
UHGXFHKHDWORVV$SURSHUO\VL]HGKHDWHUZLOOUHVWRUHQRUPDOWHPSHUDWXUHZLWKLQRQHGD\
 7XUQWKHKHDWHURIIZKHQWKHSRROZLOOQRWEHXVHGIRUDQH[WHQGHGSHULRG
 )ROORZDUHJXODUSURJUDPRISUHYHQWLYHPDLQWHQDQFHIRUWKHKHDWHUHDFKQHZVZLPPLQJVHDVRQ&KHFNRSHUDWLRQRI
WKHKHDWHUDQGLWVFRQWUROV

CHEMICAL BALANCE
POOL AND SPA WATER
<RXUSRROKHDWHUZDVGHVLJQHGVSHFL¿FDOO\IRU\RXUVSDRUSRRODQGZLOOJLYH\RXPDQ\\HDUVRIWURXEOHIUHHVHUYLFH
SURYLGHG\RXNHHS\RXUZDWHUFKHPLVWU\LQSURSHUFRQGLWLRQ
:DWHUFKHPLVWU\VKRXOGIROORZJRRGVZLPPLQJSRROZDWHUFKHPLVWU\SUDFWLFHV:KHQXVLQJDFKORULQDWRULQVWDOOLWGRZQ
VWUHDPIURPWKHKHDWHUDQGDWDORZHUOHYHOWKDQWKHKHDWHURXWOHW,QVWDOODFRUURVLRQUHVLVWDQWSRVLWLYHVHDO³&KHFN9DOYH´
315 EHWZHHQWKHKHDWHUDQGWKHFKORULQDWRUWRSUHYHQWFRQFHQWUDWHGFKHPLFDOVIURPEDFNVLSKRQLQJLQWRWKH
KHDWHU%DFNVLSKRQLQJLVPRVWOLNHO\WRRFFXUZKHQWKHSXPSVWRSVFUHDWLQJDSUHVVXUHVXFWLRQGLIIHUHQWLDO'R127
VDQLWL]HWKHSRROE\SXWWLQJFKORULQHWDEOHWVRUVWLFNVLQWRWKHVNLPPHU V :KHQWKHSXPSLVRIIWKLVZLOOFDXVHDKLJK
FRQFHQWUDWLRQRIFKORULQHWRHQWHUWKHKHDWHUZKLFKFRXOGFDXVHFRUURVLRQGDPDJHWRWKHKHDWH[FKDQJHU
7KUHH PDMRU LWHPV WKDW FDQ FDXVH SUREOHPV ZLWK \RXU SRRO KHDWHU DUH LPSURSHU S+ GLVLQIHFWDQW UHVLGXDO DQG WRWDO
DONDOLQLW\7KHVHLWHPVLIQRWNHSWSURSHUO\EDODQFHGFDQVKRUWHQWKHOLIHRIWKHKHDWHUDQGFDXVHSHUPDQHQWGDPDJH

CAUTION
Heat exchanger damage resulting from chemical imbalance is not covered by the warranty.
WHAT A DISINFECTANT DOES
7ZRSRROJXHVWV\RXGRQRWZDQWDUHDOJDHDQGEDFWHULD7RJHWULGRIWKHPDQGPDNHSRROZDWHUVDQLWDU\IRUVZLPPLQJ
DVZHOODVWRLPSURYHWKHZDWHU¶VWDVWHRGRUDQGFODULW\VRPHVRUWRIGLVLQIHFWDQWPXVWEHXVHG
&KORULQHDQGEURPLQHDUHXQLYHUVDOO\DSSURYHGE\KHDOWKDXWKRULWLHVDQGDUHDFFHSWHGGLVLQIHFWLQJDJHQWVIRUEDFWHULD
FRQWURO
WHAT IS A DISINFECTANT RESIDUAL?
:KHQ\RXDGGFKORULQHRUEURPLQHWRWKHSRROZDWHUDSRUWLRQRIWKHGLVLQIHFWDQWZLOOEHFRQVXPHGLQWKHSURFHVV
RIGHVWUR\LQJEDFWHULDDOJDHDQGRWKHUR[LGL]DEOHPDWHULDOV7KHGLVLQIHFWDQWUHPDLQLQJLVFDOOHGFKORULQHUHVLGXDORU
EURPLQHUHVLGXDO<RXFDQGHWHUPLQHWKHGLVLQIHFWDQWUHVLGXDORI\RXUSRROZDWHUZLWKDUHOLDEOHWHVWNLWDYDLODEOHIURP
\RXUORFDOSRROVXSSO\VWRUH
<RXPXVWPDLQWDLQDGLVLQIHFWDQWUHVLGXDOOHYHODGHTXDWHHQRXJKWRDVVXUHDFRQWLQXRXVNLOORIEDFWHULDRUYLUXVLQWURGXFHG
LQWRSRROZDWHUE\VZLPPHUVWKURXJKWKHDLUIURPGXVWUDLQRURWKHUVRXUFHV

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
48 Section 6. Maintenance
CHEMICAL BALANCE (continued)
,WLVZLVHWRWHVWSRROZDWHUUHJXODUO\1HYHUDOORZFKORULQHUHVLGXDOWRGURSEHORZSSP SDUWVSHUPLOOLRQ 7KH
PLQLPXPOHYHOIRUHIIHFWLYHFKORULQHRUEURPLQHUHVLGXDOLVSSP
pH7KHWHUPS+UHIHUVWRWKHDFLGDONDOLQHEDODQFHRIZDWHUH[SUHVVHGRQDQXPHULFDOVFDOHIURPWR$WHVWNLWIRUPHDVXULQJ
S+EDODQFHRI\RXUSRROZDWHULVDYDLODEOHIURP\RXUORFDOSRROVXSSO\VWRUHVHH7DEOH
0XULDWLF$FLGKDVDS+RIDERXW3XUHZDWHULV QHXWUDO :HDN/\HVROXWLRQKDYHDS+RI
58/(WRLVDGHVLUDEOHS+UDQJH,WLVHVVHQWLDOWRPDLQWDLQFRUUHFWS+VHH7DEOH
If pH becomes too high (over alkaline), it has these effects:
 *UHDWO\ORZHUVWKHDELOLW\RIFKORULQHWRGHVWUR\EDFWHULDDQGDOJDH
 :DWHUEHFRPHVFORXG\
 7KHUHLVPRUHGDQJHURIVFDOHIRUPDWLRQRQWKHSODVWHURULQWKHKHDWH[FKDQJHUWXELQJ
 )LOWHUHOHPHQWVPD\EHFRPHEORFNHG
)FP(ISTOOLOWOVERACID THEFOLLOWINGCONDITIONSMAYOCCUR
 ([FHVVLYHH\HEXUQRUVNLQLUULWDWLRQ
 (WFKLQJRIWKHSODVWHU
 &RUURVLRQRIPHWDO¿[WXUHVLQWKH¿OWUDWLRQDQGUHFLUFXODWLRQV\VWHPZKLFKPD\FUHDWHEURZQEOXHJUHHQRUVRPHWLPHVDOPRVW
EODFNVWDLQVRQWKHSODVWHU
 &RUURVLRQRIFRSSHUWXEHVLQWKHKHDWHUZKLFKPD\FDXVHOHDNV
 ,I\RXKDYHDVDQGDQGJUDYHO¿OWHUWKHDOXPXVHGDVD¿OWHUDLGPD\GLVVROYHDQGSDVVWKURXJKWKH¿OWHU
CAUTION: Do not test for pH when the chlorine residual is 3.0 ppm or higher, or bromine residual is
6.0 ppm or higher. See your local pool supply store for help in properly balancing your water chemistry.
58/(&KHPLFDOVWKDWDUHDFLGORZHUS+&KHPLFDOVWKDWDUHDONDOLQHUDLVHS+
!,+!,).)49(IGHOR,OW
³7RWDODONDOLQLW\´LVDPHDVXUHPHQWRIWKHWRWDODPRXQWRIDONDOLQHFKHPLFDOVLQWKHZDWHUDQGFRQWUROS+WRDJUHDWGHJUHH ,WLV
QRWWKHVDPHDVS+ZKLFKUHIHUVPHUHO\WRWKHUHODWLYHDONDOLQLW\DFLGLW\EDODQFH <RXUSRROZDWHU¶VWRWDODONDOLQLW\VKRXOGEH
SSPWRSHUPLWHDVLHUS+FRQWURO
$WRWDODONDOLQLW\WHVWLVVLPSOHWRSHUIRUPZLWKDUHOLDEOHWHVWNLW<RXZLOOQHHGWRWHVWDERXWRQFHDZHHNDQGPDNHSURSHUDGMXVWPHQWV
XQWLODONDOLQLW\LVLQWKHSURSHUUDQJH7KHQWHVWRQO\RQFHHYHU\PRQWKRUVRWREHVXUHLWLVEHLQJPDLQWDLQHG6HH\RXUORFDOSRRO
GHDOHUIRUKHOSLQSURSHUO\EDODQFLQJWKHZDWHUFKHPLVWU\

WATER CHEMISTRY PARAMETERS


Disinfectant levels Minimum Ideal Maximum
Free Chlorine, ppm 1.0 2.0-4.0 5.0**
Combined Chlorine, ppm None None 0.2
Bromine, ppm 2.0 4-6 10.0
Other Sanitizers Levels not established. Consult local health department before use.
Chemical Values
pH 7.2 7.4-7.6 7.8**
Total Alkalinity (Buffering), ppm 60 80-100 180
as CaCO3
Salt ppm 2000 3200 5000**
Total Dissolved Solids, ppm N/A N/A 1,500 ppm > TDS at startup*
Calcium Hardness, ppm, as CaCO3 150 200-400 500-1,000
Heavy Metals None None None
Biological Values
Algae None None None
Bacteria None None Refer to Local Code
*Start-up TDS includes source water TDS and any other inorganic salt added at start-up. Table 7.
NOTE (**): Failure to adhere to the listed water chemistry parameters may result in premature failure of the heat exchanger and will
VOIDTHEWARRANTY.

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 6. Maintenance/Replacement Parts 49

MasterTemp® 125 HEATER REPLACEMENT PARTS

For complete For complete


Electrical System Burner System
parts breakdown parts breakdown
(Key Nos. 1 through 4), (Key Nos. 5 through 7),
See Page 53 See Page 51

2 5
7

For complete
Water System
parts breakdown
(Key Nos. 8 through 9),
see Page 52

Repair Parts are available from your Pentair dealer.


If your dealer cannot supply you, call Customer Support at 1-800-831-7133.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
50 Section 6. Maintenance/Replacement Parts

MasterTemp® 125 HEATER REPLACEMENT PARTS


22

21 2
10 3

4
7
11

5
12

14 20

19

18
26
27
13 23

17

16

15

24

23

25

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 6. Maintenance/Replacement Parts 51

MASTERTEMP® 125 HEATER REPLACEMENT PARTS


REPAIR PARTS – BURNER SYSTEM
Model

Key Part MT125 NA


No. Description Qty. MT125 LP

1 Combination Gas Control Valve Kit 1 42001-0051S


2 3/4" Union 2 38404-4097S
3 Gas Orifice 1
4 Gas Orifice O-Ring 1
F as Orifice Kit – NG (Incl. Key Nos. 3 and 4)† 474981
F as Orifice Kit – Propane (Incl. Key Nos. 3 and 4)† 474980
F "G to Propane Conversion Kit
(Incl. Key Nos. 3 and 4)† 461063
F $ropane to NG Conversion Kit
(Incl. Key Nos. 3 and 4)† 461062
5 Air Blower Kit
Natural Gas Units 1 474978
Propane Units 1 474977
F ir Orifice Kit (Includes Key Nos. 6 and 7) 1 474979
6 Air Orifice Kit 1
7 Air Orifice Grill
F lower/Adapter Plate Gasket Kit
(Includes Key Nos. 8, 9, 10, 12) 1 77707-0011
F lameholder Kit (Includes
Key Nos. 10, 11, 12, 13)
1 474994
8 Blower/Adapter Plate Gasket 1
9 Blower Adapter Plate 1
10 5+6/285./:
.+9</:Plate Gasket 1
11 5+6/285./:Assembly 1
12 5+6/285./:
86,=;<387Chamber Gasket* 1
13 5+6/285./: Insulation Cap 1
F lameholder Insert 1
14 Combustion Chamber Gasket Kit 1 474952
15 One Piece Metal Chamber/Combustion Chamber
Assembly (9-bolt) 1 474990

F nsulation Kit (Includes Key No. 13, 16,17,18,19) 1 77707-0008


16 Bottom Outer Insulation Blanket* 1
17 1" Bottom Inner Insulation 1
18 1" Top Insulation 1
19 Top Outer Insulation Blanket* 1
F Lower Enclosure Insulation 1 42001-0074S
20 One Piece Metal Elbow/Combustion Chamber
Cover Assembly (9-bolt) 1 474958

21 Metal Vent Cover 1 42002-0005S


22 Heater Top 1 42002-0034Z
23 Side Panel {Service Panel} 1 474991
24 Side Panel {Manifold} 1 474992
25 Heater Bottom 1 42002-0031Z
26 &3./$+7/5B5=/&<+-4C 1 474993
27 J-Box Cover 1 42002-0041Z
28 Screws/Clips Kit, Panel (8 ea. clips & 8 ea. screws) 1 474292
F Combustion Air Intake Duct Connection Kit 1 CALL

* Not available separately.


** Not included with heater. Order separately.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
52 Section 6. Maintenance/Replacement Parts

MASTERTEMP® 125 HEATER REPLACEMENT PARTS

1
3 4 2
5
12 13
6 8

14
9
7 10
11

REPAIR PARTS – WATER SYSTEM


Model
Key Part MT125 NA
No. Description MT125 LP
Qty.
1 Tube Sheet Coil Assembly Kit (NA, LP)
(Includes Key No.3) 1 474971
2 M anifold Kit (Includes Key Nos. 3-11. Key No.12 and 13 not included.
Key Nos. 5-7 in “Electrical System”, Page 53 1 474972
3 Coil/Tubesheet Sealing O-Ring Kit 1 474973
4 Manifold Bottom Plate (*) 1 -
5 Manifold O-Ring (*) 1 -
6 Manifold Baffle Plate (*) 1 -
7 M anifold Bypass Valve (*) 1 -
8 Water Pressure Switch 1 42001-0060S
9 Manifold (*) 1 -
10 5/16" Washer, Stainless Steel (*) 6 -
11 5/16x18x2-3/4" Hex Cap screw (*) 6 -
12 Thermal Regulator 1 474989
13 Pressure Relief Valve (Recommended -
(Purchase Separately) 1 473715Z
14 1-1/2” Union Kit 1 474974

(*) Not available separately

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
Section 6. Maintenance/Replacement Parts 53

MASTERTEMP® 125 HEATER REPLACEMENT PARTS

15

14

13

16
4

11

10 6

7
12
8 7a
9

REPAIR PARTS – ELECTRICAL SYSTEM


Key Part MT125 HD NA & LP
Model 125 (NA/LP)
No. Description Qty. (International)
1 Heater Display Cover 1 42002-0035
2 Igniter Bracket 1 42001-0030S
3 Igniter/Igniter Gasket Kit Incl. Key Nos. 3 and 4) 1 77707-0054
4 Igniter Gasket 1 42001-0066S
5 Automatic Gas Shutoff Switch (AGS) 1 474368S
6 High Limit Switch 1 474367S 474369S 55° C HI LIMIT
7 Thermistor 1 42001-0053S
7a Hi-Limit Switch 45° C 1 175147S
8 Terminal Board 1 42001-0056S
9 Fireman’s Switch Fuse (1.25A, 1-1/4") 1 32850-0099
10 Ignition Control Module 1 42001-0052S 474103S
11 Transformer, 120/240V 1 42001-0107S
12 Air Flow Switch 1 42001-0061S
13 Control Board Kit (NA, LP Series) 1 42002-0007S
= Heater Wiring Harness - 120/240V 1 42001-0104S 474163S
= 120/240 Volt Plug Kit 1 42001-0105S 473764S (240 V PLUG)
14 Heater, Top 1 42002-0034Z
15 Membrane Pad (NA, LP Series) 1 472610Z
16 Stack Flue Sensor 1 42002-0024S
= ot available separately.

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
54

NOTES

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14
55

NOTES

Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide
56 

+$:.,16$9(6$1)25'1&ɒ  


:(67/26$1*(/(6$9(02253$5.&$ɒ  
www.pentairpool.com

All Pentair trademarks and logos are owned by Pentair or by one of its global affilliates. Pentair Aquatic Systems™, MasterTemp®, Intel-
liTouch®, EasyTouch®, are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies
in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document
are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc.
Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving
our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.

© 2014 Pentair Water Pool and Spa, Inc. All rights reserved. This document is subject to change without notice.

P/N 475000 REV. B 8/14

MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14