Along with the support for deleting report files of configuration information, the condition
to delete report files from Storage Navigator is changed as follows: Before: The user who
has the storage administrator (initial setting) role. If the user does not have this role, he
cannot delete report files that he previously created. After: The user who has created report
files or the user who has the storage administrator (initial setting) role. Regardless of the
role, the user can delete the report files that he previously created.
Changed Part SVP, raidinf (new tool)
1-3 New window support for external authentication server connection setting
Description New window of Storage Navigator to set connection with an external authentication server
is supported.
Changed Part Storage Navigator
1-15 Support for microcomputer chip for CPC from the 2nd vendor as backup
Description Microcomputer chip for CPC supplied by the 2nd vendor as backup is supported.
The microcomputer chip from the 2nd vendor is a substitute of the current product.
Both microcomputer chips from the current and the 2nd vendor are supported.
The shipping schedule for the 2nd vendor chip is TBD.
1
Changed Part DKCMAIN, SVP, CMBK, CUDG4
2. Mainframe System
3. OPEN System
[Function 2] When Host Mode Option 63 is set to ON, the following commands based on
T10 are supported for VAAI (ESX5.0).
1. For TC, HAM, HUR: UNMAP
2. For SI, Snapshot, VM, TC, HAM, HUR:
FULL XCOPY, Compare & Write, RECEIVE COPY RESULTS, READ CAPACITY,
STANDARD INQUIRY, and INQUIRY PAGE B0
Note: Host Mode Option 63 is available to enable the function. Public Mode – No
Permission Required to Use
Changed Part DKCMAIN
Note When downgrading the microcode to an unsupported version online, SSB=d334,d33f,d3ca
may be output without causing any problem.
The following commands for Function 1 and 2 are supported only by OPEN-V.
FULL XCOPY, Compare & Write, UNMAP, and RECEIVE COPY RESULTS
Causes and Updates New System Option Mode 781 is available to fix the problem.
Restricted Mode – Technical Support Permission Required to Use
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy
Changed Part DKCMAIN
13 Shadow Image copy stop when write pending rate over 60%
Phenomena Even though workload of a RAID group of copy target LDEV was low, if
write pending rate of CLPR on the copy target was over 60%, Shadow
Image copy was stopped.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when write pending rate of CLPR to which the
copy target LDEV of Shadow Image pair belongs is over 60%.
Causes and Updates New System Option Mode 855 and the existing System Option Mode 467
are required to be set together to continue the copy processing.
Public Mode – No Permission Required to Use
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Shadow Image or Shadow Image for Mainframe
Changed Part DKCMAIN
xxxxxx: 7060, 5099, 6012, 6023, 6036, 76500, 76501, 7310 or 78000
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an error occurs during MP blade editing such
as an operation on a blocked MP blade.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP
103 Unable to record and report SIM log files due to access error
Phenomena An access to SIM log files failed and the SIM log record and report were
disabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when an access to SIM log files fails.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP
110 Disabled FCv2 pair operation after pair suspend due to failure
Phenomena If a failure occurs during FCv2 operation, FCv2 pair in process was
suspended, and the following operation of the pair was disabled.
(SSB=9680 and 9694)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) FCv2 Establish or Withdraw command is being processed.
(3) The above command processing is stopped (a failure occurs)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible Flash Copy V2
Changed Part DKCMAIN
* In host target port which uses TC/UR VOL or external VOL, transfer
time-out occurs, or time-out for response waiting or ABTS response
waiting occurs in TC/UR or external path,
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, Universal Replicator, Universal Volume Manager
Changed Part DKCMAIN
133 Failure of pool shrink with SSB and error message output
Phenomena Pool shrink failed and SSB=AF0D was output. Storage Navigator
message appeared in this case was [3005 78043].
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DP or DT is used.
(2) A pool consists of multiple pool VOLs which vary in capacity.
(3) The pool usage rate after pool shrink is close to the capacity threshold.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning, Dynamic Tiering
Changed Part DKCMAIN
158 Failed path inline due to confliction of path inline and ORM
Phenomena Path in-line (A3/A6/A2 routine) and ORM (HDD diagnosis function)
conflicted with each other and the path in-line might wrongly fail.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when path in-line is executed from Diagnosis.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN
169 Failure of path re-creation after link down and then link up
Phenomena When a path was established in Point to Point connection without switch,
if link down and then link up occurred, the path could not be re-created
and SSB=C242 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Point to point connection without switch.
(2) A path is already created.
(3) Link down and then link up occur.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN
172 Abend of test plan due to P-path or CHK3 failure during FCoE
I/O processing
Phenomena During FCoE I/O processing, if P-path failure or CHK3 failure occurred,
a test plan ended abnormally and SSB=BD21 and BD22 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) MCH-DMA transfer is delayed.
(2) DMA transfer is stopped due to P-path or CHK3 failure.
(3) There is an FCoE event in stopped MCH-DMA transfer.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN
227 SSBs output during backup from CoW V-VOL to tape device
Phenomena During backup from CoW Snapshot V-VOL to a tape device,
SSB=14DC, 14FF and DD88 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Read commands.
(2) Conflict at the same slot.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN
240 XRC session suspend with SSBs output after CHK1 and CHK3
Phenomena During an XRC operation, CHK1 and CHK3 occurred, SSB=65EA,
65EB and 65EC were output, and the XRC session was suspended.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe
(2) Compatible XRC
(3) CHK1 and CHK3 occur during RD RECORDSET command
processing on XRC MCU.
(The problem does not occur by WCHK1)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible XRC
Changed Part DKCMAIN
Phenomenon2
(1) An LDEV whose provisioning type is BASIC is created or deleted
from Storage Navigator.
(2) Cache mode setting of external VOL is performed from RAID
Manager during the time period from execution to completion of the
above operation.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category RAID Manager
Changed Part DKCMAIN
For phenomenon 2:
The problem may occur when any of the following occurs during MPB
installation.
(1) A communication failure between SVP and DKC.
(2) A Windows error.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP
278 LDEVs wrongly created with the same LBA start point
Phenomena If Install CV (raidcom add ldev) was sequentially executed more then 3
times from CLI, LDEVs with the same LBA start point might be created.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when Install CV is executed from CLI under the
conditions below.
(1) The LBA start point of the second LDEV is smaller than that of the
first LDEV.
(2) The LBA start point of the third LDEV is smaller than that of the first
LDEV.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN