Vous êtes sur la page 1sur 107

VSP

MICROCODE VERSION 70-02-54-00/00


RELEASED 08/17/2011

Newly supported features and functions for Version 70-02-54-00/00


1. Mainframe & OPEN System

1-1 Support for CCI configuration report


Description Configuration information report files which are currently obtained from Storage Navigator
can be obtained using CCI. The supported commands are as follows:
raidinf add report (report creation)
raidinf delete report (report deletion)
raidinf download report (report download)
raidinf get reportinfo (report list display)
For syntax on each command, see Appendix B in the Storage Navigator User Guide

Along with the support for deleting report files of configuration information, the condition
to delete report files from Storage Navigator is changed as follows: Before: The user who
has the storage administrator (initial setting) role. If the user does not have this role, he
cannot delete report files that he previously created. After: The user who has created report
files or the user who has the storage administrator (initial setting) role. Regardless of the
role, the user can delete the report files that he previously created.
Changed Part SVP, raidinf (new tool)

1-2 Support for per-PCB battery life warning SIM setting


Description Setting unit of battery life warning SIM is changed as follows.
Versions V02 and earlier: Per system (one setting for a system)
Versions V02+1 and higher: Per CM battery (PCB)
Changed Part SVP

1-3 New window support for external authentication server connection setting
Description New window of Storage Navigator to set connection with an external authentication server
is supported.
Changed Part Storage Navigator

1-4 Support for SIM syslog report


Description When a RAID system failure occurs, it is directly reported to users using syslog.
Syslog server can be set from Setting -> Environment Setting -> Edit SIM Syslog Server
Settings on Storage Navigator.
Changed Part SVP

1-5 Support for 2 TB NL-SAS HDD of 7 Krpm


Description 2 TB NL-SAS HDD of 7 Krpm is supported on Model: DKS2C-H2ROSS with RAID level:
RAID5 (3D+1P, 7D+1P (*1)), RAID1 (2D+2D (*2)), RAID6 (6D+2P)
*1: Two and four-parity group concatenations are supported.
*2: Two-parity group concatenation is supported.
Changed Part DKCMAIN, CONFIG, SVP

HDS Confidential 1 of 107


1-6 Support for BB_Credit virtualization and TC Round Trip reduction
Description For long-distance connection in TC Sync, the following functions are newly supported.
1. BB_Credit virtualization function reduces protocol overhead by virtually using the value
of BB_Credit which considers frame accumulation in long-distance connection. By setting
both Host Mode Option 49 and 50 on MCU and RCU side, the number of BB_Credits can
be increased.
2. TC Round Trip reduction function can transfer data without receiving XFER_RDY from
RCU when MCU sends a command, so that round trip time of frames in long-distance
connection can be reduced. Available by setting Host Mode Option 51 on MCU and RCU
Changed Part DKCMAIN/SVP/Storage Navigator
Note (1) When BB_Credit Virtualization function is used, employ Point to Point connection.
(2) Host connection to the RCU Target port is unacceptable.
(3) The number of MCUs to be able to connect with the RCU Target port is one.
(4) This function cannot be used together with the FCSW function, which transfers data to
the Target side asynchronously by buffering the data in switch.
For example, this function cannot be used together with the Fast Write function of
Brocade Switch or the Write Acceleration function of Cisco Switch.
(5) RCU Target cannot be used for UR.
(6) Target hardware is 8 UFC and 16 UFC. (Initiator, target).
(7) When using the BB_Credit virtualization function, make sure to set SOM 769 to OFF.
(8) Make sure to enable or disable the BB_Credit virtualization/ TC Round Trip functions
after the pair is suspended or when the load is low.
(9) Before downgrading the micro-program to an unsupported version, set HMO 49, 50 and
51 to OFF. For details, see Maintenance Manual (MICRO03-140).
*: The above restrictions apply when HMO 49, 50 or/and 51 are set to ON.

1-7 Support for True Copy OPEN and Mainframe consistency


Description OPEN and Mainframe TC pairs can be registered in the same consistency group.
By issuing pair suspend command with group specified from RAID Manager or Business
Continuity Manager (BCM); all pairs are suspended while the consistency in data between
OPEN pair and Mainframe pair S-VOLs in the same consistency group are guaranteed.
If a failure suspend occurs on MCU side of a consistency group where OPEN and
Mainframe pairs are registered, all pairs are suspended while the consistency in data
between OPEN and Mainframe pair S-VOLs in the same consistency group are guaranteed.
Only True Copy Sync is supported (OPEN/Mainframe)
If group suspend is executed for S-VOL from RAID Manager, only OPEN pairs are
suspended while MF Mainframe pairs are suspended when the operation is done from BCM.
Consistency is guaranteed only in the same DKC. Consistency over different DKCs is not
supported.
Changed Part DKCMAIN, Business Continuity Manager, SVP
Note If OPEN and Mainframe pairs are registered in the same consistency group, the microcode
cannot be exchanged to an unsupported version, or delete the Mainframe pairs in the
consistency group and then exchange the microcode.

1-8 Improvement for dual SVP configuration


Description When SVP is hung-up, Windows kernel memory dump is collected before SSVP turns SVP
OFF and then ON to recover the SVP. In dual SVP configuration; If master SVP is hung-up,
Windows kernel memory dump is collected before failover is executed. If standby SVP is
hung-up, Windows kernel memory dump is collected before SSVP turns SVP OFF and then
ON to recover the SVP.
Changed Part SVP, SSVP
Note Function works when Config version matches supported SVP/SSVP microcode versions.

HDS Confidential 2 of 107


1-9 Operability improvement of Storage Navigator
Description - Back and Forward buttons are added to menu bar on Storage Navigator main window
Improvement: By storing operation records of tree, the window can be returned or
forwarded using the above buttons.
- Pie chart is improved in Allocation Summary on Storage Navigator main window
Improvement: White line is added for boundary to increase visibility and Alphabets are
assigned to graph and legend to increase accessibility.
- Unit for allocation summary can be specified in Storage Navigator main window
Improvement: Capacity display with unit specified is enabled.
- Top-20 MPB usage rates can be displayed in Performance Monitor
Improvement: For real-time display, when graphs are displayed for each MP, up to 20
operating tasks for each MP PCB can be displayed.
Changed Part SVP

1-10 GUI improvement of DP/DT


Description For a DT pool, the following setting per tier from Storage Navigator is supported.
-Buffer area rate for relocation
-Free area rate for new allocation
Changed Part Storage Navigator

1-11 New storage support


Description As external storage connection, the following storage is supported without profile tool.
FUJITSU storage: DX90/80/60
Changed Part DKCMAIN

1-12 Support for new SIM for pool volume blockade


Description When a pool volume is blocked, a SIM below corresponding to a pool to which the blocked
pool volume belongs is reported.
Changed Part DKCMAIN, SVP

1-13 Support for new CCI commands


Description The following commands are supported.
-raidcom get ldev
The following are added to display item of LDEV information
-OPE_TYPE: Pool in shrinking operation
-TIER_LEVEL: DT Tiering Policies setting (newly added)
-raidcom modify ldev
A parameter to set Tiering Policies when DP-VOL is used is added (-status)
-raidcom get pool
Pool type and status that shrinking is in process when "-key opt" is set are added
-raidcom get dp_pool
Relocation buffer amount and monitoring mode when "-key opt" is set are added.
-raidcom modify pool
A parameter to set monitoring mode and relocation buffer amount is added
-resource option is added to all of raidcom commands

For details on each command, see "RAID Manager Command Reference”.


For details on each PP function, see the corresponding PP user guide.
Changed Part DKCMAIN, RAID Manager

HDS Confidential 3 of 107


1-14 Change of response watch time for backend processing
Description System Option Mode 862 is available to shorten the response watch time for backend
processing. Restricted Mode – Technical Support Permission Required to Use.
Changed Part DKCMAIN

1-15 Support for microcomputer chip for CPC from the 2nd vendor as backup
Description Microcomputer chip for CPC supplied by the 2nd vendor as backup is supported.
The microcomputer chip from the 2nd vendor is a substitute of the current product.
Both microcomputer chips from the current and the 2nd vendor are supported.
The shipping schedule for the 2nd vendor chip is TBD.
1
Changed Part DKCMAIN, SVP, CMBK, CUDG4

1-16 PIN Deletion Tool support for Solaris 10


Description The PIN Deletion Tool is supported for Solaris 10.

2. Mainframe System

2-1 Support for EAV, MF-DP and DVE functions


Description Extended Address Volume (EAV), Dynamic Provisioning for Mainframe, and Dynamic
Volume Expansion (DVE) functions are supported as follows.
1. Supported DKU emulation type:
-EAV and DVE: 3390-A
-Dynamic Provisioning for Mainframe: 3390-A, 3390-V
2. Supported host OS:
-z/OS 1.10 and later (z/OS 1.9+PTF is also supported)
-z/VM 6.1 and later (z/VM 5.4+PTF is also supported)
3. Supported program products:
-Both the normal volume and DP volume can be used as the 3390-A volume.
-True Copy for Mainframe
-Universal Replicator for Mainframe
-Shadow Image for Mainframe
-Compatible Flash Copy V2
-Compatible XRC
- Universal Volume Manager
4. I/O synchronous page discarding is also supported.
5. HDP license can be installed even in the minimum SM configuration
Changed Part DKCMAIN, SVP, Storage Navigator, CLI
Note 1. For TC-MF; If both of MCU and RCU are RAID700, install the supported version on
both MCU and RCU. Pair creation using P-VOL of other than 3390-A and S-VOL of 3390-
A is supported, but the swap operation of P-VOL and S-VOL is unavailable. Pair creation
using P-VOL of 3390-A and S-VOL of other than 3390-A is not supported. Using an EAV
or MF-DP volume to pair with a previous model (RAID500/RAID600) is not supported.
2. For UR-MF; Pair creation using 3390-A and other than 3390-A (such as 3390-3) volumes
is unavailable. 3DC configuration using 3390-A volumes is unavailable.
3. For SI-MF, VM; Pair creation using 3390-A and other than 3390-A (such as 3390-3) is
unavailable.
4. Set SOM 871 to ON before downgrading the microcode from V02+1 or higher to V02
ICS; and set SOM 871 to OFF after the downgrade.
Restricted Mode – RSD Permission Required to Use

HDS Confidential 4 of 107


2-2 Function Switch#36 to enable time stamp option
Description In TCz/URz cascade configuration, when a TCz Sync pair is created from Storage Navigator
or BC Manager, the timestamp option is enabled, so that the timestamp of host I/O that the
TCz Sync pair receives is sent to the URz pair and the consistency of URz is maintained.
However, in the case of TCz Sync pair creation by PPRC, because the timestamp option
cannot be enabled, the consistency of URz cannot be kept. This function allows timestamp
option to be enabled at TCz Sync pair initial copy/pair resync by PPRC or failback by
enabling Function Switch#36.
Changed Part DKCMAIN
Note After microcode exchange, enable Function Switch#36.
In configuration where RCU is RAID500 (earlier than version 50-09-70-00/00), do not
enable the Function Switch#36, or TCz pair initial copy/pair resync by PPRC fails.

3. OPEN System

3-1 Support for resource ID takeover function (Virtual ID function)


Description The resource ID takeover function enables an open host to recognize a new model storage as
an old model storage. In open environment, if an inquiry command is issued from a host, the
response of the old model storage (RAID500, RAID600) is returned in accordance with the
old model storage information set per resource group.

The information to show to the host OS as old model storage is as follows.


Fibre port WWN, Model name, port name, and serial number included in inquiry command.
With implementation of the function, stopping host IO is necessary, but as the host OS
recognizes the RAID700 as an old model storage, OS reboot on the host side and change of
definition for device files are not necessary, so that the down time of the host for storage
migration can be reduced.
Changed Part DKCMAIN, SVP

3-2 Support for Server Priority Manager GUI


Description The Server Priority Manager setting from Storage Navigator window is enabled.
The Server Priority Manager is a function to set the upper limit of I/O amount, which each
port at front-end can process.
Changed Part DKCMAIN, SVP

3-3 Support for Tiering Policies per V-VOL in DT


Description Tiering Policies setting is supported. The Tiering Policies setting is a function that enables
users to specify tiers to be used by DP-VOL. For the DP-VOL with Tiering Policies
specified, all pages are allocated to tiers in the Tiering Policies. For example, if tier 1 is
specified for a DP-VOL, DT relocates the DP-VOL pages to the tier 1. In other words, no
matter how low the I/O workload in the page is, the page is allocated to the tier 1.
[Background]
In order to maximize the entire pool performance, DT allocates pages from higher tier
according to relative page ranking based on I/O workload. For this, a page with lower I/O
workload is likely to be allocated to lower tier. Depending on customer environment, there
is data with high importance but low I/O and such data should be allocated to higher tier in
some cases. However, because of low I/O workload, DT allocates the data to tier 2 or tier 3
and the data with low importance and high I/O workload may use tier 1. As a solution for
the above issue, Tiering Policies setting is supported.
Changed Part DKCMAIN, SVP

HDS Confidential 5 of 107


3-4 FCoE enhancement (PP combination/Platform)
Description 1. Combination with the following program products when FCoE is used as a I/F for host
I/O is supported. True Copy, Universal Replicator, Volume Migration. Note: Use the Fibre
channel interface as a path for remote connection between TC and UR. FCoE I/F cannot be
used for it.
2. A function to collect a dump of FCoE protocol chip is supported.
Collecting a dump of FCoE protocol chip starts with SIM=2120xx output and completes by
SSB=BCC9 output. After that, a dump of FCoE protocol chip can be collected by
performing a normal dump operation.
3. The following platforms are supported as host connection: OS, CNA, Switch
Changed Part DKCMAIN, SVP, Storage Navigator

3-5 Support for all-page discarding during LDEV format


Description All-page discarding (discarding all of the mapping information between DP pools) during
LDEV format for DP-VOL is supported. System Option Mode 867 is available to enable the
function. Public Mode – No Permission Required to Use
Changed Part DKCMAIN
Note Do not change SOM setting during LDEV format for DP-VOL.
Even if the SOM setting is changed during LDEV format, the method of format does not
change but remains as is for the volume being formatted.

3-6 Support for vStorage PP combination


Description [Function 1] The vStorage with the following additional support as follows.
1. Commands: FULL XCOPY and Compare & Write
2. Supported program products: SI , Snapshot, VM , TC , HAM , and HUR

[Function 2] When Host Mode Option 63 is set to ON, the following commands based on
T10 are supported for VAAI (ESX5.0).
1. For TC, HAM, HUR: UNMAP
2. For SI, Snapshot, VM, TC, HAM, HUR:
FULL XCOPY, Compare & Write, RECEIVE COPY RESULTS, READ CAPACITY,
STANDARD INQUIRY, and INQUIRY PAGE B0

Note: Host Mode Option 63 is available to enable the function. Public Mode – No
Permission Required to Use
Changed Part DKCMAIN
Note When downgrading the microcode to an unsupported version online, SSB=d334,d33f,d3ca
may be output without causing any problem.
The following commands for Function 1 and 2 are supported only by OPEN-V.
FULL XCOPY, Compare & Write, UNMAP, and RECEIVE COPY RESULTS

3-7 Improvement to keep previous I/O information


Description Previously collected I/O information remains even when the pool configuration is changed
by pool VOL addition.
[Background]
When the pool configuration is changed by pool VOL deletion or addition in the DT
Continuous mode, previously collected I/O information is discarded, which may cause
unnecessary page migration at tier relocation as the trend of previous I/O is not considered.
Changed Part DKCMAIN

HDS Confidential 6 of 107


3-8 RAID Manager/LIB Ver 01-15-03/05
Description Addition of some functions for checking the Resource Group.
Added flag checking resource group
Added EL_EGPERM as return value
Corrected a problem that getjnlstat() may cause a core dump over 16 LDEVs for JNL.
Changed Part RAID Manager/LIB

3-9 RAID Manager 01-25-03/11


Description Support of CLPR# option for making AoU/Snapshot
Support of Tier level for AoU volume
Addition of monitor mode for Pool
Addition of Tier buffer rate for Pool
Added deleting mode for pool
Addition of SSID to the output for querying LDEV
Addition of an option for displaying unassigned host group
Correct a problem “raidcom get ldev” reports PORTs.
Changed Part RAID Manager

3-10 Support for Snapshot combination in UR 3DC delta configuration


Description Snapshot combination is supported at L site or R site in UR 3DC delta configuration.
A Snapshot pair can be created by using a delta volume at L site or R site in UR 3DC delta
configuration as a P-VOL.
Changed Part DKCMAIN
Note Release all Snapshot pairs combined with a delta volume at L site or R site in UR 3DC delta
configuration before exchanging the microcode to an unsupported version.

3-11 Support for host group option 59


Description The online device recognition function provided by SOM 717 affects all CHF ports in a
storage system. To provide the same function per port, Host Mode Option 59 is newly
supported. Restricted Mode – Technical Support Permission Required to Use.
Changed Part DKCMAIN
Note Perform the following procedure to use this option.
Set System Option Mode 847 to ON.
Set Host Mode Option 59 to ON to the LUN Management window of SVP.
Set System Option Mode 847 to OFF.

HDS Confidential 7 of 107


The change of contents for Version 70-02-54-00/00
1 SSB=50D3 output during PAV mode switching
Phenomena In Mainframe environment, when switching the PAV mode between PAV
and hyper PAV, SSB=50D3 was wrongly output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe environment.
(2) An I/O using PAV is in process.
(3) PAV mode is switched between PAV and hyper PAV from a host.
(4) During the above (3) operation, the processing in (2) is canceled.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible PAV
Changed Part DKCMAIN

2 Unable to open detailed error information window


Phenomena When a file I/O error or media error occurred during DKU or SCHIP
micro-program exchange, if the Detail button was clicked on Version
window, a window for detailed error information was not displayed in
some cases.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur if a file I/O error or media error occurs during
DKU or SCHIP micro-program exchange.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

3 LDEV blockade and disabled access to MCU


Phenomena Under the condition that Fast Write function of Blockade Switch was
used between MCU and RCU in TC-Sync configuration, an LDEV on
RCU side was blocked and access to MCU from host was disabled.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) True Copy Sync environment.
(2) Blockade Switch is connected between MCU and RCU and Fast Write
function is used.
(3) LDEV of TC S-VOL is blocked on RCU side.

Causes and Updates New System Option Mode 781 is available to fix the problem.
Restricted Mode – Technical Support Permission Required to Use
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy
Changed Part DKCMAIN

HDS Confidential 8 of 107


4 Incorrectly completed SSD replacement
Phenomena Replacing* SSD#1 in cache PCB was requested and the SSD#1 remained
removed but the replacement ended normally. (The replacement did not
fail). * SSD alone replacement was supported in V02.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The configuration consists of a certain CMG size and number of
CMGs which allow cache data backup to SSD only using the capacity of
SSD#0. (The configuration that allows cache data backup to work
correctly without SSD#1)
(2) SSD#1 is defined in the configuration.
(3) The replacement is completed without SSD#1 installed.
Affected Products/Version DKCMAIN: 70-02-02-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

5 Unexpected DP pool initialization and failure of SI initialization


Phenomena Phenomenon1: DP pool initialization was executed while any
TC/TCz/UR/URz/SI/SIz/VM/CoW/FCv2 pair that used DP-VOL existed.
(Initialization was not guarded)

Phenomenon2: SI initialization was disabled if any TC/TCz/UR/URz pair


that used DP-VOL existed. (Storage Navigator message: 7005 68814)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
Phenomenon1
(1) TC/TCz/UR/URz/SI/SIz/VM/CoW/FCv2 pair created using DP-VOL.
(2) DP pool initialization is executed.
Phenomenon2
(1) A pair of TC/TCz/UR/URz/ is created using DP-VOL.
(2) SI initialization is executed.
Affected Products/Version DKCMAIN: All SVP: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00 SVP: 70-02-53/00
Category Dynamic Provisioning
Changed Part DKCMAIN, SVP

6 SSB=EF50 output and failure suspension of UR pair


Phenomena MP failure during a UR/URz pair restore operation, SSB=EF50 was
output and the UR/URz pair was suspended with failure.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open or Mainframe
(2) UR pair or URz pair
(3) Restore is in process. (Initial copy or update I/O is in process)
(4) An MP failure occurs on RCU.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 9 of 107


7 I/O stop with SIM=DEA0xx output
Phenomena Quorum disk failure and LDEV format executed to recover the quorum
disk, I/O stopped and SIM=DEA0xx was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence Problem may occur when conditions (1) and (2), or (1) and (3) are met.
(1) HAM pair.
(2) LDEV format is executed for a quorum disk.
(3) The data on the quorum disk is overwritten with other data.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category High Availability Manager
Changed Part DKCMAIN

8 Failure suspension with SSB=2A30


Phenomena After an HAM pair failover occurred due to an MCU failure in HAM-UR
cascade configuration, when the MCU was recovered and swap resync
was executed for the HAM pair, the pair once became "PAIR" status but
failure suspension occurred and SSB=2A30 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) There is an HAM pair.
(2) MPs are overloaded.
(3) The health check for a quorum disk turns to time-out.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category High Availability Manager
Changed Part DKCMAIN

9 Unable to refresh display information


Phenomena During Quick Format processing, if Refresh All or Refresh View was
executed from Storage Navigator, Storage Navigator message 20123-
107027 appeared and the displayed information was not updated.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Refresh All or Refresh View is executed from
Storage Navigator during Quick Format processing.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

10 Correction copy delay when Full Speed Mode ON


Phenomena The time of correction copy when System Option Full Speed Mode was
set to ON slowed down by 20%.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Correction copy is executed.
(2) Full Speed Mode is set to ON.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 10 of 107


11 Continuous failure of pair creation or reserve VOL creation
Phenomena Due to one of the following errors, SI/VM/CoW pair creation or reserved
VOL creation continuously failed.
- Storage Navigator error [7005 68837]: The command has been rejected
because the specified P-VOL is a volume of Dynamic Provisioning
whose zero data is being discarded.
- Storage Navigator error [7005 68838]: The command has been rejected,
because the specified S-VOL is a volume of Dynamic Provisioning
whose zero data is being discarded.
- Storage Navigator error [7005 68839]: The command has been rejected,
because the specified reserved volume is a volume of Dynamic
Provisioning whose zero data is being discarded.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) VXFS (Symantec) * Does not occur if VMWare Write Same is used.
(2) TC/UR pair in PAIR (Duplex) and Write Same is issued to P-VOL.
(3) Before 0 data for Write Same is discarded in S-VOL, the TC/UR pair
is deleted/created.
(4) Using the S-VOL of (3), an SI/VM/CoW pair is created or a reserved
VOL setting is performed.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

12 Prolonged periodical processing with SSBs output


Phenomena During dump collection, periodical processing took time due to a delay in
dump collection by OSW control and SSB=10FD/10FE/10FF were
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when a dump is collected.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

13 Shadow Image copy stop when write pending rate over 60%
Phenomena Even though workload of a RAID group of copy target LDEV was low, if
write pending rate of CLPR on the copy target was over 60%, Shadow
Image copy was stopped.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when write pending rate of CLPR to which the
copy target LDEV of Shadow Image pair belongs is over 60%.
Causes and Updates New System Option Mode 855 and the existing System Option Mode 467
are required to be set together to continue the copy processing.
Public Mode – No Permission Required to Use
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Shadow Image or Shadow Image for Mainframe
Changed Part DKCMAIN

HDS Confidential 11 of 107


14 Output of unrelated SSB in TC/TCz operation
Phenomena In TC/TCz operation, SSB=DD09 might be output along with
SSB=D838/D839.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC Sync or TCz Sync
(2) A internal logical contradiction (SSB=D838/D839) occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe
Changed Part DKCMAIN

15 Unexpected EPW check after track over run


Phenomena When track over run occurred at the TCz pair creation, the TCz control
information became invalid value. For this, unexpected EPW check
started at the writing on the RCU side.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) True Copy for Mainframe Sync.
(2) Track over run occurs during write I/O processing of two or more
records per one slot.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe
Changed Part DKCMAIN

16 Unable to cancel update copy after receiving SelReset


Phenomena When SelReset was received in the TCz configuration, an update copy
request could not be canceled if EC=8630 was output. In this case, when
the update copy started lately, CHK2 occurred. (EC=B2FF, 8BXX)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) True Copy for Mainframe Sync.
(2) A Write I/O issued to the 2nd or later records is received.
(3) The Write I/O is stopped. (abend, reset, or cancel occurs)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe Sync
Changed Part DKCMAIN

HDS Confidential 12 of 107


17 Wrongly continued HDD erase at PDEV replacement
Phenomena When PDEV replacement was performed during HDD Erase following
the sparing, a red LED of HDD kept lighting and another green LED of
HDD flashed because the erasing did not stop, and the following SIMs
occurred.
SIM=4C1X-XX (PDEV Erase Start)
SIM=4C3X-XX (PDEV Erase Abnormal End)
*: X-XX is C/R#.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when PDEV replacement or PDEV removal is
performed during HDD Erase.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

18 Invalid scroll box position after clicking Add or Remove on


Add LUN Paths window
Phenomena After Add or Remove was clicked on a wizard window (Add LUN Paths,
etc) of Storage Navigator, which contained two tables located next to
each other, the position of scroll box of the table where an item was
added or removed did not change.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Add or Remove is clicked on a wizard window
(Add LUN Paths, etc) which contains two tables next to each other.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

19 Incorrectly active ADD button on Create LDEVs window


Phenomena On the Create LDEVs window of Storage Navigator, the ADD button
was active even no parity group was selected. Under the condition, if the
ADD button was clicked, an error message, "The processing cannot
continue due to an internal logical contradiction” (03022-105149), was
displayed and the processing could not be continued.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when LDEV size or the number of LDEVs is entered
without selecting a parity group.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 13 of 107


20 Delay in decrease of side file usage rate during XRC operation
Phenomena During an XRC operation, even though ownership changed, the side file
usage rate for an MP PCB of side file migration source did not decrease
immediately as expected.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) XRC is in use.
(2) MP PCB maintenance, SI pair creation/deletion, or ownership
migration from CCI/Storage Navigator is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

21 Non-display of error list on the Task Properties window


Phenomena When a task status after Edit External Volumes executed from Storage
Navigator was shown "Failed", no error list was displayed on the Task
Properties window.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Edit External Volumes is executed from Storage Navigator.
(2) Task status after the above operation is "failed".
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Universal Volume Manager
Changed Part SVP

22 SSBs output after cache maintenance or a cache failure


Phenomena After cache maintenance or a cache failure, SSBs=DD86, D031, D034,
and 14DD might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) After cache maintenance is performed or a cache failure occurs.
(2) An I/O is in process, causing write pending rate to reach about 70%
per CLPR/MPB.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 14 of 107


23 Incorrectly changed page display in table on wizard window
Phenomena On a wizard window (Add LUN Paths, etc) of Storage Navigator where
two tables were displayed side by side to select an item from one table
and to add the item to another table, when an item displayed in the second
or later page was selected in one table and Add button was clicked to add
it to the other table, display of the former table was turned to the first
page.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the Add button on a wizard window (Add LUN
Paths, etc) of Storage Navigator is clicked while the second or later page
of a table from which an item is selected is displayed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

24 Display of an empty error list after clicking Apply


Phenomena When abend occurred after Apply was clicked on one of the following
Storage Navigator windows, an empty error list was displayed on the
tasks status window and the user could not confirm the root cause of the
abend.
- Delete LDEVs
- Create LDEVs
- Edit LDEVs
- Edit Encryption
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when any of the following operations is executed on
each window and the operation ends abnormally.
(1) Delete LDEVs: DP VOL or CoW Snapshot VOL deletion
(2) Create LDEVs: VOL creation and format, or concurrent VOL creation
and LDEV name setting
(3) Edit LDEVs: Concurrent LDEV name setting and tier relocation
(4) Edit Encryption: Concurrent encryption setting and format
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 15 of 107


25 Repeated command retry with SSBs output
Phenomena When an I/O is issued to a volume mapped from an external storage by
using UVM, if the response status of other than "GOOD" or "Check
Condition" is received, the threshold of response is controlled and the
volume is blocked. (This is the expected behavior) However, if abnormal
response status is determined prior to controlling threshold and the
command abort is set and reported to the host without the threshold
control, a command retry is executed until reaching the retry threshold of
the host. In this case, SSBs=8932, B236 and 8BF1 are output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Universal Volume Manager
(2) FCP_STATUS returned for the I/O issued from RAID700 to the
external storage is other than "GOOD" or “Check Condition”.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

26 Incorrect CDEV# indicated in SIM (501XYY)


Phenomena In SIM (501XYY) which was output when ORM threshold of SSD was
exceeded, CDEV# (CDEV serial number in the storage system), which is
subject to "X" in the reference code, was different from the actual
CDEV# where the failure occurred.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when ORM threshold is exceeded in SSD drives
where CDEV# is 0x01 and later.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

27 SSBs output at read/write I/O issued to a DP/DT volume


Phenomena In DP/DT configuration, when a read/write I/O was performed to a
DP/DT volume associated with a pool in which internal and external
volumes coexist, SSB=9821, 9F02, 9090, 9C0A, 9848 and so on output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DP/DT configuration.
(2) Pool volume with internal and external volumes coexist is created.
(3) DP/DT volume associated with pool volume created in (2) is created.
(4) A read/write I/O is issued to the DP/DT volume created in (3).
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning, Dynamic Tiering
Changed Part DKCMAIN

HDS Confidential 16 of 107


28 Failures caused by disabled access to part of cache
Phenomena After a failure occurred, accesses to part of cache were disabled and the
following phenomena might occur.
(1) In addition to repetitive output of SSB=9C15 and AE63, hung up
might occur.
(2) After repetitive output of SSB=13F2 and 1607, a CHECK response
might be returned to a host for accesses to some volumes.
(3) MIH or EQC might occur during I/O to some mainframe volumes.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when one of the following conditions is met.
(1) Cache capacity is 128 GB or more.
(2) After one of the following operations, a failure occurs within 30
minutes.
(a) MPB maintenance/failure
(b) LUSE combination/release
(c) SI pair creation/release
(d) CoW Snapshot pair creation/deletion
(e) JNL volume addition/deletion
(f) Ownership migration from CCI/Storage Navigator
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

29 Inadequate meaning of dialog displayed


Phenomena When Add External Volumes was executed from Storage Navigator,
Discovery Volume processing was executed by clicking the Next button
on the Select External Path Groups window while the window was
changing. The window transfer took long time and a dialog of “Now
Loading…” appeared, but what kind of processing was being executed
was not clear from the dialog.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the Next button is clicked on the Select
External Path Groups window at the execution of Add External Volumes
from Storage Navigator.
Causes and Updates The dialog message of "Now loading…" is changed to "Discovering
External Volumes…."
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Universal Volume Manager
Changed Part SVP

HDS Confidential 17 of 107


30 Failure of setting items to a mapping policy
Phenomena When an operation of Add External Volume was performed from Storage
Navigator, the following items could not be set to a mapping policy.
- Use External Storage System Configuration
- Number of LDEVs per External Volume
- Processor Blade
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the Edit Policy window of Storage Navigator is
activated.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Universal Volume Manager
Changed Part SVP

31 No display of detailed error information at an error in MP


blade editing
Phenomena When an error occurred during MP blade editing on Storage Navigator,
the task was completed and the detailed error information (20305
76501/20305 78000) was not displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an error occurs during MP blade editing such
as an operation on a blocked MP blade.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

32 XRC session suspend with SSBs output


Phenomena In XRC operation, XRC session might be suspended and SSB=133C and
1315 might be output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) XRC is in use.
(2) Side file of 128GB or more is created in the MPK.
(3) CMP PCB maintenance is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 18 of 107


33 Incomplete display of LDEV information on the Mapped
Volumes window
Phenomena On the Mapped Volumes window for external storages of Storage
Navigator, only one LDEV in the parity group was displayed, but all
other LDEVs could not be displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the Mapped Volumes window for external
storage is opened.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Universal Volume Manager
Changed Part SVP

34 No display of error message at an error in MP blade editing


Phenomena When an error occurred during MP blade editing from Storage Navigator,
message “Error Occurred.” (20305-xxxxxx) did not occur.

xxxxxx: 7060, 5099, 6012, 6023, 6036, 76500, 76501, 7310 or 78000
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an error occurs during MP blade editing such
as an operation on a blocked MP blade.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

35 Unable to execute monitoring or relocation for pool with


internal logical error
Phenomena Monitoring or tier relocation to a pool whose status was other than
normal could not be executed and an internal logical error (03122-
107007) was displayed on Storage Navigator.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A pool is in shrinking.
(2) Usage rate is 100%.
(3) Either of the following:
- Warning threshold is exceeded.
- Warning threshold and depletion threshold are exceeded.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 19 of 107


36 SSBs output at delta UR deletion in UR 3DC delta
configuration
Phenomena In UR 3DC delta configuration, when a delta UR was deleted, the
processing ended normally but SSB=EC07, EC47, EC1F might be output
frequently.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator, Universal Replicator for Mainframe
(2) TC-UR delta configuration
(3) JNL usage rate at L site is over 70%, or an I/O is issued from a host in
a configuration where command devices are allocated to all mirrors at
each site.
(4) A delta UR is deleted by an operation or is automatically deleted by a
deletion of TC pair or UR pair.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

37 SSB=CC08 at cache maintenance during I/O operation on URz


pair
Phenomena When cache maintenance was performed to a URz pair during I/O
operation, the maintenance ended normally though it took time, but
SSB=CC08 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator for Mainframe
(2) Update I/O (overwrite) is executed.
(3) Cache maintenance is performed or one side of cache is blocked.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

38 Unable to recover file system due to issuing read/write I/O to


blocked pool VOL
Phenomena When a read or write I/O was executed to an area of a blocked pool
volume, a file system might be unable to be recovered.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) A pool volume is blocked.
(2) A read or write I/O is issued to an area of the blocked pool volume in
(1).
Causes and Updates New System Option Mode 803 is available to fix this problem.

Public Mode – No Permission Required to Use


Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

HDS Confidential 20 of 107


39 Wrongly completed DP/external VOL removal and abend of
shredding
Phenomena A removal of DP or external volume which was in shredding was not
disabled but completed and the shredding ended abnormally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when a DP/external volume which is in
shredding is removed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Volume Manager, Dynamic Provisioning
Changed Part DKCMAIN

40 Unable to output pool volume operating information to an


RMF report
Phenomena Operating information per pool volume was not output to an RMF report.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe connection.
(2) DP-VOL is mounted.
(3) An RMF report is displayed.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

41 Incorrect display of RAID level on RMF report


Phenomena The RAID type displayed on an RMF report was different from the actual
RAID type.
In particular;
- RAID-5 on the RMF report when the actual RAID level was RAID1.
- RAID-5 on the RMF report in case of an external VOL.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe connection
(2) There is an ECC group in RAID1, or an external VOL exists.
(3) An RMF report is displayed.
Causes and Updates New System Option Mode 868 is available to display correct RAID levels
on RMF report.

Restricted Mode – Technical Support Permission Required to Use


Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 21 of 107


42 Failure of LDEV name setting
Phenomena LDEV deletion was performed from Storage Navigator. Before the
deletion was completed, LDEV name setting was executed for both the
LDEVs where the LDEV deletion was in process and other LDEVs for
which deletion was not performed.
In this case, the name setting for the former LDEVs failed with Storage
Navigator message (3005-78053) as expected. However, the name setting
for the latter LDEVs ended normally but the LDEV names were not set.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) LDEV name setting is performed for multiple LDEVs.
(2) Error occurs and LDEV name setting fails in any of above LDEVs.
Causes and Updates The micro-program has been modified to output Storage Navigator
message (3005-5637) when LDEV name setting fails in this case.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part SVP

43 Display of unnecessary message on EREP after SIM output


Phenomena When Environmental Recording, Editing, and Printing (EREP) was
output after DKC SIM or cache SIM output, the following message was
displayed on EREP.
"IFC264I INVALID INFORMATION FOUND FOR DASD OBR
CODE 2024 IN RECORD"
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DKC SIM or cache SIM is output.
(2) EREP is output on a Mainframe host.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

44 Unable to display LDEV Status window


Phenomena When displaying LDEV Status window was requested from DXRay, if
there was an LDEV for which any of the operations; format, quick
format, verify, or shredding, was executed, the LDEV Status window
could not be displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Displaying LDEV Status window is requested from DXRay.
(2) There is an LDEV for which format, quick format, verify, or
shredding (*) is executed.
* Any of the operations cannot be executed offline. But the configuration
information collected from a RAID700 shows that any of the operations
is being executed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 22 of 107


45 Lack of explanation for next operation in text box
Phenomena On Select External Path Group window of Add External Volumes wizard
of Storage Navigator, as no explanation for the operation was displayed
in a text box to display Path Group ID, it was difficult to understand what
to do next.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when Select External Path Group window of Add
External Volumes wizard is displayed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Universal Volume Manager
Changed Part SVP

46 SSB=9B31 output at Correction Copy, Drive Copy or Verify


Phenomena When Correction Copy, Drive Copy or Verify was executed for an ECC
group of SSD drives, SSB=9B31 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Correction Copy, Drive Copy or Verify is executed.
(2) ECC group for the above operation is executed using SSD drives.
(3) There is more than one DKA pair.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

47 No display of item for DATA TRANSFERS


Phenomena At LISTCOUNT job execution, the item of "DATA TRANSFERS" was
not displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an I/O is issued from a Mainframe host.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

48 Incorrect error message display at CHA replacement


Phenomena When 16FC CHA was replaced with 16UFC CHA, an SVP error message
[ONL2788E] showing "Error response from DKC" appeared instead of
[ONL3713E] showing "The PCB(s)(%s) could not be restored because
the PCB type is incorrect".
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A maintenance operation is performed on CHA or DKA.
(2) The above CHA or DKA is replaced or installed.
(3) A type of PCB different from the above is installed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 23 of 107


49 Additional SM accesses in purge processing
Phenomena Additional SM accesses were executed in purge processing of UR.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator or Universal Replicator for Mainframe
(2) A UR pair is in PAIR status.
(3) There is an I/O from host.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

50 Incorrect response time output by Export tool


Phenomena When a write I/O was issued to an LDEV without read I/O, the response
time of read I/O output by the Export tool was 0 instead of "-3" (invalid
value in case of no I/O). On the contrary, when an read I/O was issued to
an LDEV without write I/O, the response time of write I/O output by the
Export tool was not "-3" (invalid value in case of no I/O) but "0".
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the Export tool is used while the collected data
of option monitor is under the following condition.
- There is no read I/O and one or more write I/Os, or there is no write I/O
and one or more read I/Os.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Performance Monitor
Changed Part SVP

51 “All 0” report or MLRC error at pair status collection after a


planned power cycle
Phenomena When a pair status was obtained using a route list without any operation
from BCM after a planned power cycle (SM non-volatile), “All 0” was
reported to BCM or an MLRC error occurred with SSB=4B4F output on
the P site.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) 2DC or 3DC configuration
(2) A planned power cycle (SM non-volatile) is performed.
(3) Pair status is obtained using a route list without any operation from
BCM after (2).
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe, Shadow Image for Mainframe, Universal
Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 24 of 107


52 Incomplete status of SIM=624000
Phenomena When SIM=624000 was reported, Complete SIM was executed from
Storage Navigator but the SIM status did not turn to Complete.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SIM =624000 is reported.
(2) Complete SIMs is executed from Storage Navigator.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Dynamic Provisioning
Changed Part SVP

53 Wrong output of SSB=23FF at volume migration


Phenomena When Volume Migration was performed from Storage Navigator,
SSB=23FF was wrongly output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Multiple migration plans executed at one time from Storage NAV
(2) A plan in which a virtual volume of Dynamic Provisioning is
specified as a migration source is included in the migration plans of (1).
(3) The migration plan of (2) fails.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Volume Migration
Changed Part DKCMAIN

54 Response delay and SSB output at pair operation or pair status


collection
Phenomena When a pair operation or pair status collection was performed using a
route list from BCM, the response might unexpectedly be delayed for a
maximum of 30 seconds, and SSBs=EBD7 and EBAD were output
several times at the L or R site.
If a response is returned to a host and the host time-out is set to 45
seconds (if BCM is used, the time-out needs to be set to 45 seconds), the
above phenomenon does not affect the host.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) 2DC or 3DC configuration.
(2) A planned power cycle (SM non-volatile) is performed.
(3) Pair status is obtained using a route list without any operation from
BCM after (2).
(4) After (3), a pair operation or pair status collection is performed using
the route list from BCM.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe, Shadow Image for Mainframe, Universal
Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 25 of 107


55 Failure of decoding encryption license key
Phenomena If Normal Format/Quick Format/LDEV addition was executed with
wrong encryption license key information, the format was performed
based on the wrong information and decoding by a correct key failed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Encryption key information is wrong.
(2) Any of the following operations is performed.
(a) Normal Format
(b) Quick Format
(c) LDEV addition
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Encryption License Key
Changed Part DKCMAIN

56 Wrong output of SSB=9C61 at drive blockade


Phenomena SSB=9C61 was wrongly output at drive blockade.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SOM031 is set to ON.
(2) Correction Access is in progress.
(3) RAID5 or RAID6
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

57 Wrong re-output of SSB=620XXX for warning threshold


exceedance
Phenomena SIM=620XXX (XXX indicates a pool ID), which was supposed to be re-
reported again when DP/DT pool usage rate continuously exceeded the
warning threshold for 8 hours, was re-reported within 8 hours.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SOM734 is ON.
(2) DP/DT pool usage rate continuously exceeds the warning threshold.
(3) SIM=620XXX (XXX indicates a pool ID) reported when the usage
rate exceeds the warning threshold is completed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning, Dynamic Tiering
Changed Part DKCMAIN

HDS Confidential 26 of 107


58 Wrong output of SSB=625000 for depletion threshold
Phenomena SIM=625000, which was supposed to be output when DP/DT pool usage
rate continuously exceeded the depletion threshold for 8 hours, was
output within 8 hours.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SOM734 is ON.
(2) DP/DT pool usage rate continuously exceeds the depletion threshold.
(3) Any of the following operations is performed.
(a) Off-line micro-program exchange
(b) Planned stop of the storage system
(c) Power cut of the storage system
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning, Dynamic Tiering
Changed Part DKCMAIN

59 Abend of path inline processing with SSBs output


Phenomena Inline (A3) ended abnormally and SSB=1C00, A730, A659 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Path Inline (A3) is executed.
(2) An HDD in abnormal state due to an individual failure etc is mounted.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

60 Long processing time of path inline (A3)


Phenomena In configuration with the maximum number of DKCs, the processing time
of path inline (A3) was long.
Severity (High, Medium, Low) Low
Conditions of Occurrence Problem occurs in configuration with large number of HDDs mounted.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

61 WCHK1 and SSB=32FE occurrence during LDEV format


Phenomena During LDEV format, WCHK1 and SSB=32FE might occur.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when any of the following processing is executed
after SSB=9C89 is output.
(1) LDEV format
(2) Quick format
(3) Sequential write
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 27 of 107


62 Command reject after executing for 1281 or more times
Phenomena When the following commands were executed for 1281 or more times
from CCI, SSBs = 2EE8 and 00EE were output and the command was
rejected.
(1) raidcom delete ldev
(2) raidcom initialize ldev
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when the following commands are executed for
multiple LDEVs (more than 1280 LDEVs).
(1) raidcom delete ldev (LDEV deletion)
(2) raidcom initialize ldev (quick format)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

63 4E retry of CC or session suspend of XRC


Phenomena During Concurrent Copy (CC) or XRC operation, SSB=138A was output
and CC turned to 4E retry or XRC session was suspended.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) CC or XRC is executed.
(2) MPB maintenance.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

64 CHK3 occurrence with SSBs output (without blockade)


Phenomena When ESW was removed along with DKA removal, CHK3 occurred.
In this case, SSB=3250 and 3251 were output but no blockade occurred.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) I/O overload
(2) Maintenance with ESW removal or ESW replacement
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

65 All ports blockade when invalid setting value is detected


Phenomena When LRP detected an invalid setting value for the Tachyon chip (invalid
frame detection), all ports on a PCB where the failure was detected were
blocked.
Severity (High, Medium, Low) Low
Conditions of Occurrence Problem occurs when an invalid Tachyon chip setting value is detected.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 28 of 107


66 SSBs output at I/O to UR P-VOL
Phenomena When an I/O was issued to a UR P-VOL, SSB=D031, D034, DE4D and
DE4E were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR P-VOL is in SUSPEND status.
(2) Inflow control mode.
(3) A write I/O is issued.
(4) Pair resync is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator
Changed Part DKCMAIN

67 Frequent SSB=A466 output at CHK3 or LA error with


SSB=A443
Phenomena When CHK3 occurred (SSB=3250), SSB=A466 (access is disabled due to
post-processing for LA error) was frequently output.
If any SATA HDD was mounted, a LA error occurred one time at drive
reading and SSB=A443 was output.
* The LA error did not occur many times.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when CHK3 occurs, which does not lead to a
blockade of logical path between DKA and MP.
(The case that SSB=3250 is output but not SIM=33xx-xx)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open of Mainframe
Changed Part DKCMAIN

68 Storage Navigator display failure such as incorrect page status


Phenomena (1) When 0 data page discarding was executed, the page status on Storage
Navigator was not "Reclaiming Zero Pages".
(2) Configuration changes made from Storage Navigator, SVP, CCI or
HDVM was not reflected on Storage Navigator window.
(3) Refresh View or Refresh All was executed from Storage Navigator,
Storage Navigator message [20123-107027] appeared.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when any of the following operations is being
executed.
(1) 0 data page discarding.
(2) Write Same.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 29 of 107


69 Incorrect order display of LDEVs with the same MP operating
rates
Phenomena In the rank order of LDEVs whose MP operating rates were the same, an
LDEV with Backend kernel was placed higher than that with Open-target.
When the MP operating rates were the same, LDEVs should be ranked
according to kernel type from Open-Target, Open-External, Open-
Initiator, Mainframe-Target, Mainframe Initiator, Backend to System in
that order.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when collected MP data of option monitor data is
displayed in graph on Performance Monitor window of Storage
Navigator, or the data is output by Export tool while "group PhyMPPK"
command is active in configuration where MPs are mounted.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Performance Monitor
Changed Part SVP

70 XRC pair suspension and SSBs output due to CHK2 after


receiving CCW chain
Phenomena After a CCW chain command was received, CHK2 occurred, SSB=3289,
3570, B2FF, B21B, 5871, B2C8, 481E and 4732 were output, and an
XRC pair was suspended.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Compatible XRC
(2) A write up data command or write up key and data command, which
can write data to record0 and record1 (key length =0, data length =8) by
the same CCW chain, is received.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible XRC
Changed Part DKCMAIN

71 Failure of DP-VOL format with SSB output after slot busy


Phenomena During DP-VOL format, slot busy occurred (SSB=7B5D). After that,
Destaging might end abnormally (SSB=7B97), and then the format might
fail (SSB=7B0A).
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) External and internal pools coexist.
(2) DP-VOL format is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 30 of 107


72 Incomplete pair status change at snapshot data collection
Phenomena When snapshot data was obtained using At-Time Snapshot function,
some pairs whose pair status could not be changed remained in a
consistency group and SSB=9721 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Snapshot data is obtained using At-Time Snapshot function.
(2) The license expires before the status of all pairs in a consistency group
changes completely.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Copy-on-Write Snapshot
Changed Part DKCMAIN

73 Unable to log into Storage Navigator after repeated log-out


Phenomena After log-out from Storage Navigator in a way different from normal
logout, such as clicking "x" button in the upper right of browser, was
repeated, login to Storage Navigator failed. Even after 10 minutes which
was time-out time, login was still disabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Login, logout and then login Storage Navigator fails.
(3) Logout in a way different from normal logout, such as clicking "x"
button in the upper right of browser, is repeated.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open
Changed Part SVP

74 Memory volatilization at storage activation with SIM and SSB


output
Phenomena At offline CM DIMM replacement, if a DIMM whose type was different
from the configuration information was wrongly mounted even in one
cluster, the storage system was activated with memory volatilized and
SIM=FFE8-00 and SSB=15A7 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when the storage system is activated while the
configuration definition and the type of mounted DIMM are inconsistent.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 31 of 107


75 Incorrect display of progress status after communication error
Phenomena When a communication error between SVP and DKC occurred during
DKU, SSW or Expander micro-program exchange, "Transfer to physical
device" on a window to display the progress status was over 100%. 30
minutes after that, the micro-program exchange ended abnormally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a communication error between SVP and DKC
occurs during DKU, SSW or Expander micro-program exchange.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

76 Delay of low workload I/O response


Phenomena Due to a delay of XRC RSCB deletion (2 msec), low workload I/O
response of SEQ-UPWRITE (BLK=26KBx5 (A5 command x 5)) became
slower than that of RAID600 (version V08).
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when an XRC pair exists.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible XRC
Changed Part DKCMAIN

77 Pair status remaining in COPY or MCU JNL full


Phenomena When a failure slot occurred in a UR volume, SSB=D2B7 and D346 were
output and the UR pair status remained in COPY, or UR journal copy
stopped and a journal on MCU became full.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR MCU.
(2) A failure slot occur in a volume used by UR.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

78 Unable to log into Storage Navigator


Phenomena During an operation on Storage Navigator, a Storage Navigator error
message [20121-107022] was displayed and Storage Navigator was
terminated. After that, login to Storage Navigator was disabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence Problem may occur with the following operations executed in order.
(1) SVP micro-program is installed.
(2) At 20 minutes after SVP reboot, SVP mode is changed from Modify
mode to View mode.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 32 of 107


79 Unintentional wait dialog display
Phenomena When battery change was executed on SVP Maintenance window, a wait
dialog appeared on the right bottom corner.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when battery change is executed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

80 WCHK1 resulting from loop CHK3 due to unidentified failed


part
Phenomena When a failure in SW was detected, the failure part could not be
identified in rare cases, which caused CHK3 loop resulting in WCHK1.
In this case, SIM=3080 or 3073 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur in rare cases when a failure in SW is detected.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

81 No output of SIM for failure


Phenomena When an ESW PCB failure or X-path cable failure was detected at
power-on, a SIM for the failure was not output. (SSB=3560 was output)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an ESW PCB failure or X-path cable failure is
detected at power-on.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

82 Enable to delete a LU in host I/O processing or a reserved LU


Phenomena When LU deletion was executed from Raid Manager for an LU which
was in host I/O processing, the LU was deleted. LU deletion for a
reserved LU was enabled too.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when LU deletion from Raid Manager is executed
for an LU which is in host I/P processing or for a reserved LU.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 33 of 107


83 SSB output in TC Sync operation
Phenomena TC or TCz operation, SSB=14E6, DF12, D160, D036, D099 may output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) True Copy or True Copy for Mainframe.
(2) UA is detected in TC S-VOL.
(3) An error (such as disconnection, implicit logout) is detected in
transfer processing of check condition due to UA.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe
Changed Part DKCMAIN

84 PIN error and LDEV blockade


Phenomena During a TC pair resync operation, LDEV blockade and PIN errors
occurred in a raid-group consisting of SSDs (Solid State Disk). SSB =
C45B was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) P-VOL of True Copy for Open or Mainframe.
(2) A temporary drive failure occurs and the data cannot be read even by
correction read.
(3) Initial copy or resync is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe.
Changed Part DKCMAIN

85 Incorrect error judgment leading to failure of CMG blockade


Phenomena While a failure DIMM where uncorrectable error and correctable error
occurred in the same CMG was mounted on a cache PCB, if PS-ON was
performed, a failure was detected by diagnosis but it was determined as a
correctable error and CMG was not blocked. SIM=760400 and
SSB=3306 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A failure DIMM where uncorrectable and correctable errors occur in
the same CMG is mounted on a cache PCB.
(2) PS-ON is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 34 of 107


86 Unable to activate SVP launcher
Phenomena When logging into SVP from Remote Desktop, Storage Navigator SVP
launcher might not activate.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Access to SVP launcher activation setting file set to Windows registry
is disabled because the file is deleted or other reasons.
(2) Log-in to SVP from Remote Desktop
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

87 WCHK1 in all MPs


Phenomena At PS-ON, WCHK1 might occur in all MPs.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) PS-ON.
(2) A correctable error occurs in CMMG used as Cm Dir/CM.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

88 Failure suspension causing all differential data copy


Phenomena When any operation, cache replacement (maintenance), or a power cycle
(nonvolatile) was executed for UR while a PIN occurred in a journal
volume, failure suspension occurred with SSB=EDDD output causing all
differential data copy.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator, Universal Replicator for Mainframe
(2) Journal group status is other than Initial and Stop.
(3) A PIN occurs in a journal volume.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 35 of 107


89 SSB=5348 at the MP PCB dummy replacement
Phenomena When MP PCB dummy replacement was performed while an I/O was
issued to a DP-VOL of a pool consisted of external volumes, SSB=501F
(Time-over of Sync command JOB) and 505F (No ownership when
restarted) were output, and then SSB=5348 (Information complementing
SSB for DAK not transmitted at WaitSENSE migration) was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when SSB=501F and 505F occurs.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

90 Unable to delete pool VOL (shrink) with SSB output


Phenomena Pool VOL deletion (shrink) might be disabled and SSB=AF0D was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DP pool or DT pool.
(2) Multiplying the number of pages of maximum pool VOL capacity by
the number of allocated pages in the pool is larger than 0xFFFFFFFF
pages.
* Page calculation:
Open-V: 42 MB/page
Mainframe: 38 MB/page
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Tiering
Changed Part DKCMAIN

91 Failure of DP-VOL deletion with Storage Navigator message


Phenomena When DP-VOL deletion was executed, Storage Navigator message [3205
2011] appeared and DP-VOL deletion failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DP-VOL
(2) TC or HAM P-VOL.
(3) The pair status is PAIR or COPY.
(4) Host I/O is being executed.
(5) A swap operation for P-VOL and S-VOL is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning, True Copy, High Availability Manager
Changed Part DKCMAIN

HDS Confidential 36 of 107


92 SSB=EC84 output at SPLIT operation
Phenomena When SI was combined with UR pair S-VOL and SPLIT was executed,
SSB=EC84 was output at UR S-VOL.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR pair in PAIR or Duplex status.
(2) Update I/O is issued to UR P-VOL.
(3) SI pair (or CoW) is combined with UR S-VOL.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

93 UR pair status remaining after power cycle or offline micro-


program exchange
Phenomena When a UR pair was suspended in Duplex status or during pair deletion,
or failure suspend processing, PS-OFF/ON or offline micro-program
exchange was executed on RCU side, the UR pair status remained
Suspending or Deleting.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator or Universal Replicator for Mainframe
(2) While a pair is in Suspending status by a suspend operation or due to a
failure, or is in Deleting by a pair deletion operation, either (a) or (b)
below is performed.
(a) After performing PS-OFF for RCU, SM volatile or nonvolatile PS-
ON is performed.
(b) Online micro-program exchange on RCU side.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

94 Display remaining of MP Reboot window


Phenomena When MP Reboot window displayed during DKCMAIN or RAMBOOT
micro-program exchange was continuously moved by clicking mouse, the
MP Reboot window might remain displayed after the completion of MP
reboot processing.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DKCMAIN or RAMBOOT micro-program is exchanged.
(2) MP Reboot window is continuously moved by clicking mouse.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 37 of 107


95 SSB=3300 output at abend of micro-program exchange
Phenomena If SSW or Expander micro-program exchange ended abnormally due to
an SSW hardware failure, SSB=3300 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an error occurs in SSW during SSW or
Expander micro-program exchange.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

96 Failure of maintenance or SI pair operation after failure reset


Phenomena After a failure reset, SSB=15B9 was output and cache, LDEV, or PDEV
related maintenance or an SI pair operation failed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when a failure reset occurs after the following
operation (1) or (2) is performed.
(1) Cache, LDEV or PDEV related maintenance.
(2) SI pair operation. * Problem occurs when a failure reset occurs in a
specific program step during queue operations on job management areas.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

97 Failure of pool shrink operation with SSB=AF0D output


Phenomena When a pool shrink operation was executed from Storage Navigator,
Storage Navigator message [0305 078043] appeared, and the operation
failed with SSB=AF0D output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
1. 0 data discarding is executed.
2. 0 data discarding is stopped.
3. Rebalance (pool expansion, pool shrink, or tier relocation) is activated.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

98 Continuous SSB=AF01 output after Define Configuration


Phenomena After online Define Configuration, SSB=AF01 was continuously output
at a minute interval.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Maintenance and Provisioning setting is performed from SVP.
(2) Within a minute after the above operation, online Define
Configuration is executed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 38 of 107


99 Failure of TC pair creation with SSBs output
Phenomena When a TC pair was created in N_port connection, the creation failed and
SSB=D9A7 and D985 were output from RCU.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) N_port connection
(2) TC pair configuration where MCU is RAID700 and RCU is
RAID600.
(3) Any of the following is executed or occurs while a path is established.
(a) Link down
(b) PS-OFF and then PS-ON
(c) CHT replacement
(d) Offline micro-program exchange
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

100 Unchanged UR pair status


Phenomena In UR Open MxN configuration, when Group Deletion was requested
from Raid Manager for a JNLG where UR pairs in PSUS status and UR
pairs in PAIR or COPY status coexisted, the status of UR pairs which
was in PAIR or COPY status remained Deleting.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator
(2) Open MxN configuration
(3) In the same JNLG, UR pairs in PSUS status and UR pairs in PAIR or
COPY status coexist.
(4) From Raid Manager, Delete per group is requested for the UR pairs in
PSUS status. (The top pair in Config file of Raid Manager is in PSUS
status)
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator
Changed Part DKCMAIN

101 Unable to identify failed drive on Maintenance window


Phenomena Due to a temporary drive failure when performing PS-ON, if drive
activation failed, the failed drive could not be identified on SVP
Maintenance window and SSB=1C00 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when obtaining an ID of a failed drive fails at PS-
ON.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 39 of 107


102 Failed operation from Storage Navigator due to SVP reboot
Phenomena In a time period of SVP periodical reboot, SVP was rebooted even though
an operation from Storage Navigator was in process and the operation
failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when any operation is performed from Storage
Navigator during SVP periodical reboot processing.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

103 Unable to record and report SIM log files due to access error
Phenomena An access to SIM log files failed and the SIM log record and report were
disabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when an access to SIM log files fails.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

104 LA error and possible PDEV blockade due to JNL VOL


deletion during quick format
Phenomena When a journal VOL in quick format processing was deleted from a
journal group, an LA error occurred and PDEV might be blocked.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator for Mainframe, and the journal VOL is
Mainframe emulation VOL.
(2) While the status of UR pair is COPY or PAIR, Purge Suspend is
executed or failure suspension occurs.
(3) A journal VOL in quick format processing is deleted.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

105 Abnormality of Flash time-out error dialog


Phenomena On Storage Navigator Main window, a dialog of Flash time-out error
(20121-107096) could not be fully displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a Flash time-out error (20121-107096) occurs.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 40 of 107


106 Incorrect message display at volume migration
Phenomena If a TC secondary volume (S-VOL) in Pending status was selected as a
migration source VOL on Volume Migration window of Storage
Navigator, and then Volume Migration was executed, a Storage
Navigator error occurred as expected, but the message [5205 5506]
displayed was not correct.

5205 5506: The specified volume cannot be migrated because it is used


as P-VOL in the following status.
- A volume of True Copy or True Copy for Mainframe in the Pending
status.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) TC S-VOL in Pending status is selected as a migration source VOL.
(2) Volume Migration is executed.
(3) An error occurs.
Causes and Updates The micro-program has been modified to display the correct message
[5205 5504].

5205 5504: The specified volume cannot be migrated because it is used as


S-VOL in the following status.
- A volume of True Copy or True Copy for Mainframe in the Pending
status.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Volume Migration
Changed Part SVP

107 Time-out error and unintentional SVP reboot 30 minutes after


pool creation
Phenomena 30 minutes after pool creation on Create Pools window of Storage
Navigator, a time-out error, Storage Navigator message [0004 6001],
occurred and SVP was rebooted.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following condition is met.
Pool creation takes more than 30 minutes. (The time required for pool
creation varies depending on the number of pools to create and the
number of logical devices to be selected)
* Even a time-out error occurs, the actual pool creation continues on
DKC side and pools created do not have any problem.
Affected Products/Version SVP: 70-01-62/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Dynamic Provisioning
Changed Part SVP

HDS Confidential 41 of 107


108 Incorrect message displayed at encryption setting
Phenomena If an encryption setting was made on Edit Encryption window while
blocked and not blocked parity groups coexisted, a Storage Navigator
error occurred as expected but the message [3005 68786] displayed was
not correct.

[3005 68786] The specified parity group is not blocked.


Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an encryption setting is performed while
blocked and not blocked parity groups coexist.
Causes and Updates The message [3005 68786] is modified as follows.

A parity group that is not blocked is included in the specified parity


groups.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Encryption License Key
Changed Part SVP

109 Incorrect value output by RMLIB command


Phenomena When an RMLIB command to output system status was executed from a
host, the output value of rminfo (DKC-CACHE) CMB of write pending
data was larger than the actual value.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an RMLIB command below is executed on the
host.
- test_getrminfo_DKC_CACHE dsp_on
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

110 Disabled FCv2 pair operation after pair suspend due to failure
Phenomena If a failure occurs during FCv2 operation, FCv2 pair in process was
suspended, and the following operation of the pair was disabled.
(SSB=9680 and 9694)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) FCv2 Establish or Withdraw command is being processed.
(3) The above command processing is stopped (a failure occurs)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible Flash Copy V2
Changed Part DKCMAIN

HDS Confidential 42 of 107


111 Delay in rebalance processing
Phenomena Rebalance processing delayed.
Due to the above delay, when pool shrink was executed from Storage
Navigator, the task status seemed not to make progress.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when rebalance processing (pool expansion, pool
shrink, and tier relocation) is executed.
* In particular, the problem likely occurs if an I/O is issued to a rebalance
target DP-VOL or if cache load is high.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

112 Drive blockade due to continuous Check Condition occurrence


Phenomena During I/O processing, if Check Condition [01/00xx], [01/1D00], and
[01/40xx] occurred sequentially, a drive was blocked.
In this case, SSB=A401 and A434, and SIM=EF1X-xx were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a drive failure occurs during I/O processing.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

113 Incorrect SSBs output at virtual VOL creation by CCI


command
Phenomena At creation of a virtual VOL for DP by a CCI command,
(1) If a pool ID for CoW Snapshot was specified, an error occurred as
expected but SSBs output (2EFF and FFFF) were incorrect.
(2) If a pool ID for an un-mounted pool was specified, an error occurred
as expected but SSBs output (2E10 and 6014) were incorrect.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following condition (1) or (2) is met.
(1) At virtual VOL creation for DP by a CCI command, a pool ID of
CoW Snapshot is specified after -pool option.
(2) At virtual VOL creation for DP by a CCI command, a pool ID of an
un-mounted pool is specified after -pool option.
Causes and Updates The micro-program has been modified to output the correct SSBs in each
case.
(1) SSB=2E30 and 6003 are output instead of 2EFF and FFFF
(2) SSB=2E20 and 6000 are output instead of 2E10 and 6014
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

HDS Confidential 43 of 107


114 Inadequate SI consistency rate
Phenomena The consistency rate of Shadow Image for Mainframe pair in Duplex
status did not become 100%.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) A write I/O is issued to an SI/SIz pair.
(2) The pair status is as follows.
(a) PAIR in case of Shadow Image
(b) Duplex in case of Shadow Image for Mainframe
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Shadow Image, Shadow Image for Mainframe
Changed Part DKCMAIN

115 Frequent SSB=3B07 output at time-out occurrence


Phenomena If time-out occurred before completing initial setting for PCB Rev
collection, SSB=3B07 was frequently output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
1. Operating MP PCB removed and mounted w/o maintenance operation.
2. Any of the following operations is executed.
(a) PCB Rev window is opened from Maintenance window.
(b) Auto Dump is executed with Normal Dump selected.
(c) PCB maintenance is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

116 SSB=9C4A output and incomplete read I/O


Phenomena True Copy configuration, SSB=9C4A output and incomplete read I/O.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) True Copy
(2) TC P-VOL is a DP-VOL and an external volume.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy
Changed Part DKCMAIN

117 Memory leak at LDEV nickname reference


Phenomena Memory leak (about 2 MB) occurred while viewing LDEV nicknames.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when either of the following conditions is met.
(1) An LDEV nickname is set or changed.
(2) All Refresh is executed.
Affected Products/Version SVP: 70-01-61/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 44 of 107


118 I/O interruption with SSB=BC4F output
Phenomena During I/O processing, when an MP failure occurred, the I/O partially
stopped and SSB=BC4F was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when one of the following conditions is met.
(1) MP PCB is removed.
(2) An MP failure occurs.
* The problem occurs if link down or link up occurs due to the above
operation or failure, and a reset at link down is executed after receiving
Port Database Changed.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

119 I/O interruption with SSB=BC3B output


Phenomena During I/O processing, if a cache error was executed, the I/O stopped
partially and SSB=BC3B was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when any of the following conditions is met.
(1) A cache failure
(2) An ESW failure
(3) A CHF PCB failure
* The problem may occur if any above failure occurs and data transfer
stops due to a CHK2 failure.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

120 Pair suspend with SSB output at pair status change


Phenomena When pair status change was executed in TC configuration, the pair was
suspended and SSB=86D2 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Any of TC, UR and UVM configurations
(2) I/O processing of external port or MCU is reset. (*)
(3) The Exchange# to be reset is the same one used by the same MP.
In the above condition, the response to the reset I/O is received.

* In host target port which uses TC/UR VOL or external VOL, transfer
time-out occurs, or time-out for response waiting or ABTS response
waiting occurs in TC/UR or external path,
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, Universal Replicator, Universal Volume Manager
Changed Part DKCMAIN

HDS Confidential 45 of 107


121 Abend of concurrent copy or suspend of XRC pair creation
Phenomena When an external VOL in concurrent copy or XRC pair creation
processing was deleted, SSB=477E was output, and the concurrent copy
ended abnormally or XRC pair creation processing was suspended.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an external VOL is deleted during concurrent
copy or XRC pair creation.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Volume Manager
Changed Part DKCMAIN

122 Possible MIH occurrence with SSB=1602 output


Phenomena When an update I/O was executed for an FCv2 source volume (S-VOL),
MIH might occur and SSB=1602 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) A volume is used by multiple pairs, and SRC and TGT coexist.
(3) CCHH range of copy source and copy target of the SRC pair is
partially overlapped. (No problem if completely matches)
(4) An update I/O is issued to the above overlapped area.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

123 Unclear information output to audit log


Phenomena DKU micro-program exchanged, [+{Micro Kind, Old Ver, New
Ver}={DKU(SCSIR2G), 004F01,004F01}] was output to audit.log, but
the relation with HDD type on micro media was unclear.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when DKU micro-program is exchanged.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

124 Link down with SSBs output during FCoE operation


Phenomena During an FCoE operation, link down occurred and SSB=B6FB and
BC4F were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) During I/O processing, SCSI reset is received from a host.
(2) Immediately after reset response, PLOGI is received from the host.
(3) In the post-processing for transfer abend, internal resource is depleted
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 46 of 107


125 Wrongly active button for DT function window
Phenomena When executing remote log-in to SVP while there was no P.P. supporting
Dynamic Tiering, a button to activate DT function window did not
become inactive.
Monitor Pools
Stop monitoring Pools
Start Tier Relocation
Stop Tier Relocation
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) P.P. supporting DT (Dynamic Provisioning, Dynamic Tiering) is not
available.
(2) A button for DT function window activation is displayed from SVP
remote log-in.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

126 WCHK1 in normal MP with SSB and SIM when MPB


blockade
Phenomena When an MPB was mounted to a blocked location without any
maintenance operation, WCHK1 occurred in a normal MP. In this case,
SSB=32FA and SIM=3073xy and 3080xy were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs When an MPB is mounted to a blocked location
without any maintenance operation.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

127 Incorrect normal end of maintenance operation


Phenomena Even though reserving DXBF resource failed, a maintenance operation
ended normally and SSB=A066 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence Problem occurs with any of the following maintenance operations
- DKA replacement
- SSW replacement
- PDEV replacement
- DKA installation or removal
- DKU installation or removal
- PDEV installation or removal
- SSW micro-program exchange
- EXP micro-program exchange
- DKU micro-program exchange
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 47 of 107


127 SSB=548D output at DP-VOL creation
Phenomena When a DP-VOL was created, SSB=548D was output.
(The problem was just log output and no effect on the DP-VOL)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a DP-VOL is created.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

129 Failure of automatic cache directory recovery after CHK3


Phenomena During automatic cache directory recovery, CHK3 occurred frequently
and the recovery failed. (SIM=0xFFEE0x)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when there is a blocked CM PCB in a cluster where
the automatic cache directory recovery is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

130 Incorrect usage rate display of migration target


Phenomena During migration plan creation by Volume Migration, the estimated
usage rate of migration target displayed in a graph did not include the
usage rate of migration source.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The usage rate of migration source is 1% or higher.
(2) Migration plan is created.
(3) A graph of migration target is displayed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Performance Monitor
Changed Part SVP

131 Failure of migration plan creation due to internal logical error


Phenomena After [Make New Plan] was clicked on Auto Plan window to create
migration plan, Storage Navigator message [5205 7423] showing a
internal logical error appeared and the migration plan was not created.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) There is a parity group whose usage rate within a time period
specified as sampling term is higher than the threshold of HDD class
where the parity group belongs to.
(The lower the HDD class threshold, the higher the occurrence frequency)
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Volume Migration
Changed Part SVP

HDS Confidential 48 of 107


132 I/O error due to no record
Phenomena After LDEV format with SOM305 set to ON, if OS IPL of z/VSE system
was executed, an I/O error due to no record might be detected.
(An error message appeared on the host console)
Severity (High, Medium, Low) Low
Conditions of Occurrence Problem occurs when reading track#2 and later of cylinder#0 from a host.
(VOL formatted while SOM305 is ON creates records up to track#1 of
cylinder#0)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

133 Failure of pool shrink with SSB and error message output
Phenomena Pool shrink failed and SSB=AF0D was output. Storage Navigator
message appeared in this case was [3005 78043].
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DP or DT is used.
(2) A pool consists of multiple pool VOLs which vary in capacity.
(3) The pool usage rate after pool shrink is close to the capacity threshold.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning, Dynamic Tiering
Changed Part DKCMAIN

134 Host I/O long response time with SSBs output


Phenomena Slow response to host I/O and SSB=DD86, 14DD and 13F3 may output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Cache capacity is over 128GB.
(2) I/O load concentrates on a specific MPB.
*Problem is more likely to occur if random property of host I/O is strong.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

135 MP blockade resulted from LDEV deletion during I/O


Phenomena If a logical VOL was deleted during I/O processing from a Mainframe
host, an MP was blocked and SSB=1644 might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) I/O from Mainframe host is in process.
(2) An LDEV is deleted.
(3) Unit check occurs for the I/O and receiving sense command from the
Mainframe host takes one second or more.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe

HDS Confidential 49 of 107


136 NOP of CLI command when 1,280 CLI commands in process
Phenomena When CLI (raidcom) asynchronous commands were sequentially issued
and there were 1280 commands waiting for processing or in process in
DKC, a NOP would occur if another CLI command was issued
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) 1,280 CLI (raidcom) asynchronous commands are being processed.
(2) Another CLI (raidcom) command is issued.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

137 SSB=2CC7 output at TC/UR pair deletion


Phenomena When a TC/UR pair was deleted, SSB=2CC7 might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) A TC/UR pair is created using DP-VOL.
(2) Immediately after the above pair creation, the pair is deleted.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

138 SSB=4470 output and failure suspension


Phenomena When offline micro-program exchange or volatile PS-OFF/ON was
performed, SSB=4407 was output. In this case, if there was any UR pair
in COPY or PAIR status, failure suspension occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator, Universal Replicator for Mainframe
(2) JNLG is already defined.
(3) Offline micro-program exchange, or volatile PS-ON after PS-OFF.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

139 Path failure with SSBs output during FCoE processing


Phenomena During FCoE processing, a path failure occurred and SSB=B6FB and
BC4F were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A host I/O is processed using a port of CHG PCB.
(2) 512 or more commands are received from the host.
(3) SCSI reset is received from the host.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 50 of 107


140 SSB=9C3E due to conflict of rebalance and cache maintenance
Phenomena When cache maintenance and rebalance processing conflicted each other,
SSB=9C3E might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence May occur if the operations below are performed at the same time.
(1) Cache maintenance
(2) Rebalance (pool expansion, pool shrink or tier relocation)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

141 SSB=12DF output during I/O to TC P-VOL


Phenomena During an I/O to TC P-VOL, SSB=12DF might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC pair configuration
(2) 342 or more write I/Os are issued to TC P-VOL at the same time.
(3) For the above write I/Os, time-out occurs frequently. (Overload, path
disconnection, or a failure)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy or True Copy for Mainframe
Changed Part DKCMAIN

142 Non-execution of PP expiration processing


Phenomena If SVP was never logged in after SVP reboot, SVP launcher did not
activate. In this case, if PP expiration processing was executed, SVP
launcher check mounted on PP activation part determined as no launcher
and the PP expiration processing was not executed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) No log-in to SVP after reboot.
(2) PP expiration processing is executed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

143 SSB=8971 output during TC pair creation


Phenomena At TC pair creation, SSB=8971 was output on target VOL side.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DP pool VOL contains an external VOL.
(2) No page is allocated to a DP-VOL associated with the above pool.
(3) TC pair is created using the DP-VOL of (2) as P-VOL.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

HDS Confidential 51 of 107


144 Application error during Define Configuration and Install
Phenomena During Define Configuration and Install processing, an application error
may occur.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when Define Configuration and Install is
executed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

145 "Aborted command" on a host with SSB=D1F3 output


Phenomena "Aborted command" appeared on a host and SSB=D1F3 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) External storage system
(2) Cache mode is set to "Disable".
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

146 SSB=137E and 137F output at recover from CM PCB failure


Phenomena Recovery from a CM PCB failure, SSB=137E and 137F might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Configuration where CM PCBs are 4 PCBs or more.
(2) Any operation accompanied with LDEV ownership migration (MPK
maintenance/ failure, LUSE combination/release, SI pair creation/release,
CoW Snapshot pair creation/deletion, JNL volume addition/deletion,
ownership migration from CLI/Storage Navigator) is executed.
(3) After the above operation, a CM PCB failure occurs.
(4) The failed CM PCB is recovered.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

147 Unable to reflect configuration change done from SVP


Phenomena Configuration change done on SVP was not reflected to Storage
Navigator window.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when one of the following conditions is met.
(1) After configuration change from SVP, and maintenance from SVP.
(2) After configuration change from SVP, Refresh of Storage Navigator
fails.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 52 of 107


148 SSB output and MP blockade during Open I/O or TC/TCz
Sync processing
Phenomena During an Open I/O operation or TC/TCz Sync operation, SSB=1644 was
output and MP might be blocked.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open I/O or TC/TCz Sync.
(2) An error (such as link down, implicit logout) is detected during
transfer processing of status.
(3) I/O is overloaded.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open, True Copy, True Copy for Mainframe
Changed Part DKCMAIN

149 Incorrect display of raid group usage rate


Phenomena (1) On Performance Adviser which monitored operating rate, the usage
rate of raid group exceeded 100%.
(2) On Performance Monitor of Storage Navigator, the usage rate of raid
group displayed was higher than the actual rate.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An I/O is issued from a host.
(2) Performance Monitor of Storage Navigator is turned ON, or
Performance Adviser of operating rate monitoring tool is activated.
(Monitoring data collection of Performance Monitor and Performance
Adviser, and monitoring data update of DKC are not in right timing)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

150 MIH occurrence due to a failure during background copy


Phenomena When a failure occurred during FC background copy processing, MIH
might occur and SSB=1602 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe.
(2) FC pair with Incremental specified.
(3) Reset occurs just before the completion of background copy.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 53 of 107


151 Disabled log-in to Storage Navigator with error message
Phenomena During Storage Navigator operation, Storage Navigator message [10121
107022] appeared and Storage Navigator was terminated. After that log-
in to Storage Navigator was disabled with Storage Navigator message
[10123-107025].
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) After remote log-in to SVP, the mode is changed to "Modify".
(2) SVP [Install] button is clicked and Install dialog opens.
(3) In the condition of (1) and (2), a LAN cable is plugged off and left
disconnected for more than a minute.
(4) More than 30 minutes passes after (3).

After that, log-in to Storage Navigator is disabled even SVP mode is


changed to "View".
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

152 Wrong LU reset due to SAS port blockade or link down


Phenomena When DMA transfer time-out occurred at SAS port link down or
blockade, LU reset was wrongly issued and SSB=1B2E and SIM=0F12-
xx were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when SAS port blockade or link down occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

153 SSB=A73B output if DKA port recovery fails


Phenomena If DKA port recovery failed, SSB=A73B was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a hardware failure occurs during DKA port
recovery in any of the following maintenance.
(1) DKA replacement
(2) SSW replacement
(3) DKA installation
(4) DKU installation
(5) SSW micro-program exchange
(6) EXP micro-program exchange
(7) DKA micro-program exchange
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 54 of 107


154 Multiple SSB=8E04 output
Phenomena When offline DKC micro-program exchange on UR MCU side was
performed, or PS ON was performed, SSB=8E04 might be output on
MCU side more than 10 times.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator or Universal Replicator for Mainframe
(2) MCU DKC
(3) A volatile power cycle is performed for MCU.
(4) System Option Mode449 is set to ON to RCU.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

155 Drive blockade and no progress of reboot on SVP


Phenomena A drive was blocked during the time between the completion of SCHIP
micro-program exchange download processing and reboot initiation, and
the reboot processing status displayed on SVP did not make a progress.
SSB=DFxx, and EFxx.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a HDD failure occurs during the time between
the completion of SCHIP micro-program exchange download and reboot
initiation and then a drive is blocked.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

156 Failed micro-program exchange after time-out due to no


available resource
Phenomena When EXP or SSW micro-program was exchanged while I/O was
overloaded, time-out to wait for resource occurred and the exchange
failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) EXP or SSW micro-program exchange
(2) No resource is available. (It may occur in case of I/O overload and in
large configuration)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

HDS Confidential 55 of 107


157 Decrease in command multiplicity
Phenomena When HDD micro-program was exchanged, time-out occurred in transfer
from cache to DXBF and command multiplicity decreased.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) HDD micro-program exchange
(2) Time-out occurs in transfer from cache to DXBF.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

158 Failed path inline due to confliction of path inline and ORM
Phenomena Path in-line (A3/A6/A2 routine) and ORM (HDD diagnosis function)
conflicted with each other and the path in-line might wrongly fail.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when path in-line is executed from Diagnosis.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

159 Failed installation of DKA PCB with SSBs output after


CHT/CHG PCB removal
Phenomena When CHT PCB was removed and then DKA PCB was installed in the
same location, SSBs=B615 and B2E4 were output and the installation
failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CHT PCB or CHG PCB is blocked.
(2) The blocked CHT PCB or CHG PCB is removed.
(3) DKA PCB is installed in the location where CHT PCB or CHG PCB
is removed.

Affected Products/Version DKCMAIN: All


Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

160 No output of SIM for external temperature problem


Phenomena The following SIMs which were supposed to be output when external
temperature problem occurred were not output.
SSB=BF1010, BF1110, BF1210, BF1011, BF1111, BF1211, BF1012,
BF1112, BF1212, BF1013, BF1113, and BF1213
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when an external temperature problem occurs.
Affected Products/Version SSVP: All
Fixed Product/Version SSVP: 70-02-53/00
Category Open and Mainframe
Changed Part SSVP

HDS Confidential 56 of 107


161 Invalid information contained in SSVP dump
Phenomena When SSVP dump was collected, invalid data was contained in the
header of SSVP dump data and architecture. In particular,
(1) SSVP DUMP was SSVP MP.
(2) Minute and second of DUMP collection time were incorrect.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when SSVP dump is collected.
Affected Products/Version SSVP: All
Fixed Product/Version SSVP: 70-02-53/00
Category Open and Mainframe
Changed Part SSVP

162 Failed data writing and actual value reading


Phenomena A request of environment monitor read and write for an interface between
SVP and SSVP succeeded but the data was not written in some cases.
Also, the actual value could not be read.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when register write and read of DKCMAIN is
executed from a PC for production line test.
Affected Products/Version SSVP: All
Fixed Product/Version SSVP: 70-02-53/00
Category Open and Mainframe
Changed Part SSVP

163 No output of SIMs for internal temperature warning/alarm


disagreement
Phenomena SIM=BFA4A4 for internal temperature warning disagreement of CLI on
module1 side was not output.
SIM=BFA3A5 for internal temperature alarm disagreement and BFA4A5
for internal temperature warning disagreement of CL2 on module1 side
was not output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when internal temperature warning disagreement of
CL1 on module1 side, or internal temperature alarm/warning
disagreement of CL2 on module1 side is detected.
Affected Products/Version SSVP: All
Fixed Product/Version SSVP: 70-02-53/00
Category Open and Mainframe
Changed Part SSVP

HDS Confidential 57 of 107


164 Failure suspension with SSB=EF47 output after SSB=FE13
Phenomena Hours after resync operation following I/O processing while a UR pair
was in SUSPEND status, SSB=EF13 was output on RCU side, and then
SSB=EF47 was output and failure suspension occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR or UR for Mainframe pair
(2) Update I/O while pair status is PAIR or COPY
(3) SSB=EF13 is output on RCU side.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

165 Delay in response to I/O in port with no SCSI reset


Phenomena If SCSI reset occurred frequently, response to an I/O in port where the
SCSI reset did not occur was delayed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when one of the following occurs.
(1) Frequent SCSI reset
(2) Frequent link failure
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

166 Hang-up with SSBs output during reset processing


Phenomena Reset hang-up occurred and SSB=1609 and 10FF were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when one of the following occurs.
(1) Frequent SCSI reset
(2) Frequent link failure
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

167 Incorrect progress status of LDEV format


Phenomena The progress status of LDEV format might not be displayed correctly.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) 73 or more LDEVs are selected.
(2) The above LDEVs contain LDEVs whose emulation type is 3390-A
(without DP VOL attribute).
(3) LDEV format (excluding quick format) is executed.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 58 of 107


168 Wrongly enabled maintenance for DP-VOL or pool VOL
Phenomena Maintenance (blockade, format, recovery) for DP-VOL or pool VOL was
wrongly enabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when one of the following conditions is met.
(1) For a pool VOL of DP pool with which a not-blocked DP-VOL
associated, blockade or format is executed.
(2) DP-VOL associated with a blocked DP pool is, blockade is executed.
(3) For a DP-VOL which is associated with a DP pool whose pool VOL
is blocked, format or recovery is executed.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

169 Failure of path re-creation after link down and then link up
Phenomena When a path was established in Point to Point connection without switch,
if link down and then link up occurred, the path could not be re-created
and SSB=C242 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Point to point connection without switch.
(2) A path is already created.
(3) Link down and then link up occur.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

170 Abend of SSW or Expander micro-program exchange


Phenomena When SSW or Expander micro-program was exchanged on a system
without DKU, the exchange ended abnormally and SVP message [2433
E] appeared.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DKU is not installed.
(2) SSW or Expander micro-program is exchanged.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: All
Category Open and Mainframe
Changed Part SVP

HDS Confidential 59 of 107


171 Abend of test plan with SSB output when reset occurs during
FCoE I/O processing
Phenomena If reset occurred during FCoE I/O processing, a test plan ended
abnormally and SSB=BC3B was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A reset is received from a host during I/O processing in FCoE port.
(2) Response to a reset target command is being transferred.
(3) ABTS is received from the host for the reset target command.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

172 Abend of test plan due to P-path or CHK3 failure during FCoE
I/O processing
Phenomena During FCoE I/O processing, if P-path failure or CHK3 failure occurred,
a test plan ended abnormally and SSB=BD21 and BD22 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) MCH-DMA transfer is delayed.
(2) DMA transfer is stopped due to P-path or CHK3 failure.
(3) There is an FCoE event in stopped MCH-DMA transfer.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

173 SSB=B695 output in port different from the failed port


Phenomena When a cable of FCoE port was disconnected and connected, SSB=B695
was output in other ports.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A link failure is detected in FCoE port.
(2) Both of the following occur.
(a) A Tag# obtained at link failure is not consistent with the one
calculated at receipt of Notify Acknowledge.
(b) A Tag# obtained at link failure is reserved in a port different from the
one where the link failure occurs.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 60 of 107


174 Incorrect version display of SSW, Expander and DKAF
Phenomena When micro-program was exchanged on a system without DKU, the
versions of SSW, Expander and DKAF on Replace (current) side were
displayed as "xx-xx-xx".
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
- Failure of SSW and Expander version display
(1) DKU is not installed.
(2) Micro-program exchange is performed.
- Failure of DKAF version display
(1) DKA is not installed.
(2) Micro-program exchange is performed.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

175 Incorrect display of PP expiration on license key window


Phenomena At Config micro-program exchange, PP expiration check was stopped by
SVP reboot and SIM=7FF7 was output, but configuration information
displayed on license key window of Storage Navigator was not updated.
For this, the PP was not expired on the license key window.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when any of the following conditions is met.
(1) It is 13:00 o'clock while SVP mode is other than View and SVP is
rebooted without changing the mode to View.
(2) It is 13:00 o'clock during maintenance which requires SVP reboot and
the SVP reboot is not yet performed, and then SVP is rebooted before
date changes.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

176 Wrongly same LBA start points of LDEVs


Phenomena When a command was executed from CLI in the order below, LBA start
points of LDEVs created in (1) and (2) were the same.
(1) Install CV command was requested.
(2) CoW Snapshot VOL creation was requested for the LDEV# same as
that in (1).
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Install CV command is received from CLI.
(2) CoW Snapshot VOL creation is requested with the same LDEV#
specified before the processing result is reflected to the actual
configuration.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 61 of 107


177 Command reject after CoW Snapshot VOL creation fails
Phenomena After CoW Snapshot VOL creation from CLI failed (SSB=2E30, 4119)
failed, a command of configuration change for the VOL specified at the
CoW Snapshot VOL creation from CLI was rejected. (SSB=2E11, 0153)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when CoW Snapshot VOL creation fails and
SSB=2E30 and 4119 are output.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

178 Pair suspend due to MPB failure during TC initial copy


Phenomena During TC initial copy, MPB failure occurred and the pair might be
suspended.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC initial copy is executed.
(2) MPB failure occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

179 Unable to calculate monitoring information of page


Phenomena When an I/O was issued to a page of external VOL of DT pool (including
external VOL), the monitoring information of the page was not
calculated.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) UVM is used.
(2) DT pool
(3) Emergency destage
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

180 High Write Pending rate resulting in MIH and SSB


Phenomena When XRC was in use, Write Pending went over 70%, MIH occurred and
SSB=1602 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) There is an XRC pair.
(2) Write Pending of MPB where XRC utility VOL exists is high.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible XRC
Changed Part DKCMAIN

HDS Confidential 62 of 107


181 Wrongly enabled LDEV installation while 1024 LDEVs exist
Phenomena While 1,024 LDEVs existed in a RAID group of RAID1 (2D+2D) or
RAID5 (3D+1P), when LDEV installation was executed from CLI to the
same Raid group, the LDEV could be created.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) 1,024 LDEVs exist in a RAID group of RAID1 (2D+2D) or RAID5
(3D+1P).
(2) LDEV installation is executed from CLI with the same RAID group
specified.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

182 Incorrect display of non-mounted LDEV available to select on


Logical Devices window
Phenomena On Logical Devices window, when a LDEV which was displayed on the
window but not mounted was selected and then any of the following
operation was executed, the LDEV information was not displayed on
Confirm window. In this case, if Apply was clicked, Storage Navigator
message [20122 106004] appeared.
- Format LDEVs
- Block LDEVs
- Shred LDEVs
- Restore LDEVs
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following operations are executed in that
order.
(1) On Logical Devices window, a LDEV is selected and Delete LDEV is
executed.
(2) Before the above operation is completed, Logical Devices window is
displayed for 5 minutes (until the operation is completed).
(3) The LDEV selected in (1) is selected and Format LDEVs, Block
LDEVs, Shred LDEVs or Restore LDEVs is executed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open Volume Management, Virtual LVI
Changed Part SVP

183 SSB output at MP PCB removal


Phenomena When an MP PCB was removed during the duplex pair creation between
2 storages, SSB=8BE9 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when an MP PCB is removed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 63 of 107


184 Incorrectly enabled operations
Phenomena On Logical Devices window, when LDEVs other than those with Access
Attribute of read/write were selected and then any of the following
operation was executed, a Wizard could be opened.
- Format LDEVs
- Shred LDEVs
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the following operations are executed in that
order.
(1) On Data Retention window, a LDEV is selected and Access Attribute
is changed to Read Only or Protect.
(2) On Logical Devices window, the LDEV selected in (1) is selected and
Format LDEVs or Shred LDEVs is executed.
Causes and Updates The micro-program has been modified to fix the problem.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open Volume Management, Virtual LVI
Changed Part SVP

185 Incorrect message display on host side log


Phenomena Messages such as "Input/output error" was displayed on a log on host
side.
(A test plan might stop)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CHG port
(2) Reset is received during data transfer.
(3) Reset target command is queued.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

186 Failed MPB maintenance with WCHK1


Phenomena When MPB replacement was performed after ESW PCB replacement
failed, WCHK1 occurred in the replaced MPB and maintenance failed.
SIM=3072, 3073, and 3080
SVP message ONL2412
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) ESW PCB replacement or installation fails. Or ESW PCB removal
and installation without maintenance is performed.
(2) After the above operation, MPB is replaced or installed.
(3) Micro-program version on FM in the above MPB is before V02.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 64 of 107


187 Memory leak of 254Kbytes
Phenomena During Storage Navigator operation, memory leak of about 254Kbytes
occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when Option tab of Shadow Image or Shadow Image
for Mainframe is opened, or the window is updated while the tab opens.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

188 Increased time to enable log-in to Storage Navigator


Phenomena The time to enable log-in to Storage Navigator after SVP activation
increased 10 minutes at the maximum.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when SVP micro-program is downgraded from the
version 70-02-03/00 and higher to 70-01-61/00.
Affected Products/Version SVP: 70-01-61/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

189 Incorrect version display on MP Ver tab


Phenomena DKA Port version displayed on MP Ver (Curt/Running) tab of Version
window was incorrect. In particular,
- The version of SAS#1-Port#1 was displayed in SAS#0-Port#1.
- The version of SAS#0-Port#0 was displayed in SAS#1-Port#0.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when DKAF version corresponding to SAS
controller is inconsistent.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

190 LDEV blockade after SM nonvolatile and CM volatile


Phenomena At powering OFF and nonvolatile power ON after offline micro-program
exchange failed, SM was not volatilized and CM volatilized, and then a
LDEV was blocked. (SVP message SMT2433 E was output)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when power OFF and nonvolatile power ON is
performed after offline micro-program exchange fails.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 65 of 107


191 Host time-out or MIH occurrence with SSBs output
Phenomena At CPC replacement, host time-out or MIH occurred and SSB=1602,
1603, DD86, D031, D034, DE4E, DE4D, 14DD etc., might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) There is a CLPR in capacity less than that recommended in
Maintenance Manual and users guide.
(2) There is XRC/CC pair.
(3) CPC replacement or CPC replacement after failure
(4) Side file capacity increases.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

192 SSB=59F0 output during FCv2 copy processing


Phenomena During FCv2 copy processing, SSB=59F0 (byte44-45: 0x0901) was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe system
(2) Flash Copy version2
(3) A write I/O is issued to FCv2 source VOL (S-VOL). (Host I/O or
configuration where FCv2 S-VOL is combined with secondary VOL of
other PP for copy)
(4) FCv2 copy is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Flash Copy version2, Shadow Image for Mainframe
Changed Part DKCMAIN

193 Failure of SSWs display in message after removal fails


Phenomena In a system with DKU-00/01/02 were mounted, when DKU-02 was
removed, the removal failed due to SSW cable failure. At this time, only
SSWs in the top DKU (DKU-00) were displayed in a message
[ONL4189] to prompt SSW dummy replacement.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) DKU removal
(2) Operation other than removal from DKU minimum configuration in
DKC
(3) The above operation fails due to SSW hardware failure.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 66 of 107


194 Performance degradation and time-out error
Phenomena In all Storage Navigator operations, performance degraded or time-out
error (1-4011) might occur.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Operation after logging into Storage Navigator
(2) A user program which logs into the same SVP via RMI executes log-
in and log-out many times.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

195 Incorrect performance value display


Phenomena By Performance Monitor, when monitoring data had been collected for
the maximum monitoring term, the performance value output was larger
than actual value.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Monitoring data has been collected for the maximum monitoring term.
(2) The performance value is displayed from the oldest data or output by
Export tool.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Performance Monitor
Changed Part SVP

196 TC/TCz pair suspension with SSB=1042 output


Phenomena A TC pair/TCz pair in copy processing was suspended and SSB=1042
was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) True Copy/True Copy for Mainframe is in use on MCU.
(2) The pair status on RCU side is changed (including operations from
SVP) or a path failure occurs during update I/O to TC P-VOL/TCz M-
VOL.
(3) MCU side is overloaded. (overload likely causes LMJCB depletion)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe
Changed Part DKCMAIN

HDS Confidential 67 of 107


197 Unintentional returning ownership to source MPB
Phenomena For XRC utility LDEV, ownership migration with user specified was
supposed to be enabled while a session was suspended, but the ownership
might be unintentionally returned to migration source MPB.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) There is a XRC pair
(2) HPAV is set to XRC utility LDEV.
(3) LDEV ownership migration of the utility LDEV is requested while a
session is suspended.
(4) After the above operation, session resync is executed.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible XRC
Changed Part DKCMAIN

198 Not shared upper limit by WWNs in group with non-priority


control
Phenomena When multiple WWNs were registered by Server Priority Manager
(WWN) or RMLIB (WWN), and then all of registered WWNs were
registered in one of groups with non-priority control and the upper limit
was set, but the upper limit was not shared by WWNs in the group.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Multiple WWNs are registered by Server Priority Manager or
RMLIB.
(2) The registered multiple WWNs are registered in a group, which is set
as non-priority control target, and the upper limit is set.
(3) Among WWNs in the non-priority control group, there are some
WWNs to which I/Os are issued.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

199 Suspend or temporary high JNL usage rate (70%)


Phenomena When online micro-program was exchanged in UR, UR delta resync or
UR Mainframe 4x4 environment, the following might occur and
SSB=BBAC was output.
(1) Suspend
(2) In case of delta resync, JNL usage rate became 70% temporarily.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR, UR delta resync or UR Mainframe 4x4 environment.
(2) Online micro-program exchange is performed.
(3) Data transfer which occurs in the above environment takes time.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 68 of 107


200 Disabled TC/UR pair operation
Phenomena LDEVs in a device group could not be referred from RAID Manager and
TC/TCz and UR/URz pair operations (paircreate, pairresync, pairsplit)
were disabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Volatile power ON or offline micro-program exchange is performed
while a device group exists.
(2) After the above operation, RAID Manager is rebooted.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

201 Memory leak at communication failure during pool


name/LDEV nickname setting
Phenomena At pool name or LDEV nickname setting, if communication between
SVP and DKC fails, memory leak occurred (about 233KB).
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when communication between SVP and DKC fails at
pool name or LDEV nickname setting.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

202 Disabled upper limit control after LDEV ownership migration


Phenomena When the upper limit was set by Server Priority Manager (port, WWN) or
RMLIB (WWN) and the ownership of LDEV which would receive I/Os
from the registered port or WWN was migrated, the upper limit control
was disabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The upper limit is set by Server Priority Manager (port, WWN) or
RMLIB (WWN).
(2) The ownership of LDEV which receives I/Os from the registered port
or WWN is migrated.
(3) The ownership of the above LDEV is returned to the previous MP
PCB.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 69 of 107


203 Memory leak with invalid LDEV specified
Phenomena During Shadow Image setting operation, if a resource group of specified
LDEV# was invalid, memory leak (about 2MB) occurred.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a resource group of specified LDEV# is invalid
at Shadow Image setting operation.
* Resource group of LDEV# will not be invalid actually.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

204 SSB=59F0 output during FCv2 copy processing


Phenomena During FCv2 copy processing, SSB=59F0 (byte 0x44-0x45: 0x1c00) was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe system
(2) Flash Copy version2
(3) FCv2 copy is in process.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Flash Copy version2
Changed Part DKCMAIN

205 No display of WWNs logged in


Phenomena When multiple WWNs were connected with a port and then the WWN
connected first was disconnected, all of WWNs which were being logged
in by test_getrminfo_PPC_LOGIN were not displayed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Multiple WWNs are connected with a port.
(2) Among connected WWNs, WWNs other than that connected last are
disconnected.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

206 No SSBs for overload output at cache overload


Phenomena When cache was overloaded, SSB=D354, D355, D356, D35C, E669,
E66A, and E66C indicating overload were not output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open
(2) Cache overload
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 70 of 107


207 Delay in I/O response to host after SSB=14DD output
Phenomena In the system with multiple-CLPR configuration where a CLPR whose
Write Pending was over 70% existed, when a MP PCB was replaced,
SSB=14DD for waiting available segment was output and I/O response to
host was delayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) More than one CLPRs are defined.
(2) There is a CLPR whose Write Pending is over 70%.
(3) Any of the following operations accompanied with ownership
migration is executed.
- MP PCB maintenance/failure
- LUSE connection/release
- SI pair creation/release
- CoW Snapshot pair creation/deletion
- JNL VOL addition/deletion
- Ownership migration from CLI or Storage Navigator
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

208 SSB=13D9 output


Phenomena SSB=13D9 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when SATA-E drive or OSW function is used.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

209 Disabled TC pair creation with SSB=C310 output


Phenomena At TC Mainframe pair creation, SSB=C310 was output and pair creation
might be disabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) PCM
(2) TC Mainframe pair creation or resync
(3) NVS is OFF.
(4) CMF PCB is mounted in the second module only.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe
Changed Part DKCMAIN

HDS Confidential 71 of 107


210 HDD blockade with SIMs output
Phenomena An HDD was blocked after the threshold was exceeded and SIM=
DF6XYY, DF7XYY, DF8XYY, and DF9XYY were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An HDD failure occurs.
(2) LU reset which is post-processing of the HDD failure turns to time-
out.
(3) The HDD is not blocked immediately after the failure.
(4) The threshold is exceeded.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

211 TC failure suspension with SIM/SSB output after cache PCB


blockade
Phenomena When a cache PCB was blocked during host I/O to a TC P-VOL,
SIM=0xd41003 and SSB=B839 were output, and only one of TC pairs
was suspended by failure.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) True Copy or True Copy for Mainframe.
(2) A host I/O is issued to a TC pair.
(3) Cache failure blockade occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe
Changed Part DKCMAIN

212 Failure of UR/TC pair creation with SSBs output


Phenomena In 3DC configuration with direct Point-to-Point connection, when a UR
pair was created between RAID700 and RAID600, SSB=D004, EBEF
were output and the pair creation failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Direct Point-to-Point connection.
(2) TC or UR connection.
(3) Initiator port is on RAID700 side.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, Universal Replicator
Changed Part DKCMAIN

HDS Confidential 72 of 107


213 Degradation of maximum performance when LDEV ownership
is not equally assigned
Phenomena If LDEV ownership was not equally assigned to LDEVs in a PG, the
multiplicity of commands to drives tended to excessively increase.
If LDEV ownership was equally assigned to LDEVs in a PG, the
multiplicity of commands to drives tended to decrease.
For this, the maximum performance when LDEV ownership was not
assigned slightly degraded.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SATA drive is mounted, or SOM862 is set to ON.
(2) LDEV ownership is not equally assigned to LDEVs in a PG. (At
PDEV installation, LDEV ownership is automatically assigned)
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

214 Taking longer time to block drive port


Phenomena The time to block a drive port when command time-out occurred was
longer than that in the specification. (SSB=A4C2)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Command transfer at the first request ends abnormally.
(2) Command time-out occurs at retry request.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

215 Taking longer time to execute SI pair split and resync


Phenomena Split and resync operation of SI/SIz pair took longer time.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SI copy for 3 or more pairs is executed.
(2) SI pair split or resync is executed. (*)
* The problem likely occurs when there is no difference in data.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Shadow Image, Shadow Image for Mainframe
Changed Part DKCMAIN

HDS Confidential 73 of 107


216 WCHK1 occurrence in MP different from blocked MPs with
SSBs and SIMs output
Phenomena During LDEV format for a mainframe volume, if a failure which caused
all MPs (4MP) in an MPB to be blocked occurred, WCHK1 occurred in
an MP of another MPB. In this case, SSB=1644 and 32FE, and
SIM=3080 and 3073 were output one time.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe LDEV format is executed.
(2) A failure leading to blockade of all MPs in an MPB occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

217 Wrong drive blockade when SOM862 is set to ON


Phenomena When time-out occurred while System Option Mode 862 was set to ON,
LU Reset failed and a drive was wrongly blocked. (SSB= A4C2 or A4C5
and SIM= EFXX-xx)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SOM862 is set to ON.
(2) I/O is overloaded.
(3) Command time-out occurs. (LU Reset fails)
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category HDD
Changed Part DKCMAIN

218 Install CV command reject with SSBs output


Phenomena When Install CV (raidcom add ldev) was executed from CLI, SSB=2ECD
and 0000 were output and the command was rejected.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Install CV is executed from CLI.
(2) The above processing is stopped by reset.
(3) Install CV is executed from CLI again while the same RAID group# is
specified.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 74 of 107


219 Creation of LDEV with the same LBA start point
Phenomena When Install CV was executed more than 4 times in series from CLI,
LDEV with the same LBA start point might be created.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) The different RAID group# is specified in the first Install CV and the
second Install CV.
(2) In the second and later Install CV, the same RAID group# is specified.
(3) LBA start point of the third LDEV is smaller than that of the second
LDEV.
(4) LBA start point of the fourth LDEV is smaller than that of the second
LDEV.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

220 Command reject and SSBs output


Phenomena When external group deletion was executed from CLI, the command was
rejected and SSB=2E11 and 0153 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a MP reset occurs in the synchronous
processing of Install CV command with external group specified.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

221 Command reject with SSBs output due to logical confliction


Phenomena The following commands from CLI were rejected and SSB=2E11 and
0153 were output.
- Install CV
- Volume to Space
- LDEV format (normal, quick)
- LDEV blockade/recovery
- DP-VOL deletion
- CoW Snapshot VOL creation
- CoW Snapshot VOL deletion
- Shredding
- External VOL creation
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a logical confliction occurs in DKC.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 75 of 107


222 Unable to complete asynchronous command and no result
returned
Phenomena Asynchronous command being executed could not be completed and get
command_status did not return the result.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when logical inconsistency occurs in DKC.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

223 Incorrect displayed or output Long range LDEV usage rate


Phenomena The displayed Long range LDEV usage rate or the Long range LDEV
usage rate with "PhyLDEV" command specified output by Export Tool
might be incorrect.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) A disk failure occurs.
(2) Memory depletion
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Performance Monitor
Changed Part SVP

224 Wrong usage rate exceeding 100%


Phenomena Due to a bug, the usage rate displayed in graph on Performance Monitor,
or that output by Export Tool might exceed 100%.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Monitoring switch is turned ON and monitoring data is being
collected.
(2) The cycle to collect monitoring data in several times becomes wrong.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Performance Monitor
Changed Part SVP

225 No display of monitoring data for 1 plot


Phenomena PS OFF and ON was performed while option monitor switch was ON and
the data was collected, the monitoring data for 1 plot was not displayed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Option monitor switch is ON.
(2) PS OFF and ON is performed.
(3) Option monitor data is displayed.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Performance Monitor
Changed Part SVP

HDS Confidential 76 of 107


226 Long response for host I/O with SSBs after frequent output of
SSB=1315
Phenomena After SSB=1315 was frequently output, long response occurred for a host
I/O and SSB=DD86, 14DD, 13F3 and 1315 might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Cache capacity is 128GB or larger.
(2) I/Os concentrate on a specific MPB.
(3) SSB=1315 are frequently output.
* The problem is more likely to occur if random property of host I/O is
strong.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

227 SSBs output during backup from CoW V-VOL to tape device
Phenomena During backup from CoW Snapshot V-VOL to a tape device,
SSB=14DC, 14FF and DD88 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Read commands.
(2) Conflict at the same slot.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

228 Abend with SSBs output


Phenomena In FCoE environment (with TC/UR pair), if the power was turned OFF
during I/O to P-VOL, all I/Os issued to the TC P-VOL ended abnormally.
At the same time SSB=1699, D051 and B839 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC P-VOL
(2) The pair status is PAIR or COPY.
(3) A write I/O is issued.
(4) Blockade or delay of path between DKCs
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy
Changed Part DKCMAIN

HDS Confidential 77 of 107


229 Delay in host I/O response increase of MP operating rate
Phenomena During a resync operation for a UR pair, MP operating rate of JNL owner
MPB where the UR pair belonged to increased and host I/O response was
delayed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR P-VOL belongs to RAID700.
(2) Resync is executed for the UR pair.
(3) A host I/O is issued to the above RAID700.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

230 Slowed item selection and scrolling operation


Phenomena On Main window of Storage Navigator, selecting item on a table and
scrolling became slow. Depending on the spec of PC being used, browser
didn't respond. (No Responding was displayed at the top of window)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occurs if a lot of items on the table are selected. (no
response time is about 4 seconds for 5000 items)
The degree of performance degradation varies depending on PC spec and
the number of items selected.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

231 SSBs output at FCv2 pair creation


Phenomena Because numbers after the decimal point are truncated on Storage
Navigator Subscription (Current) display, if the total capacity of DP-VOL
for the pool capacity is over 100% and under 101%, the display is 100%
and it seems for users that the pool capacity is equal to the DP VOL
capacity.
Under the above condition, when FCv2 pair was created (COPY from
TSO) using non DP-VOL (external VOL) and DP-VOL, SSB=AFB0 and
AF83 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The total capacity of DP-VOL for the pool capacity is over 100% and
under 101%.
(2) Pair creation is executed for all DP-VOLs associated with a pool.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 78 of 107


232 WCHK1 in MP causing WCHK1 in another MP
Phenomena When WCHK1 occurred in an MP due to a hardware failure, WCHK1
might occur in another MP in some cases.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when WCHK1 occurs in an MP due to a
hardware failure.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

233 XRC pair suspension after SSBs output following CHK2


occurrence
Phenomena After CCW chain was received, CHK2 occurred, SSB=3289, 3570,
B2FF, B21B, 5871, B2C8, 481E and 4732 were output, and XRC pair
was suspended.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Compatible XRC
(2) There is an FCv2 pair whose source VOL is XRC pair primary VOL.
(3) In a command to write data to multiple records in the same track, retry
to wait for FCv2 copy occurs while there is a record written by the same
CCW chain.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible XRC
Changed Part DKCMAIN

234 TC pair suspension or Check Condition with SSB


Phenomena A TC Sync pair was suspended due to SSB=B826, or Check Condition
was returned due to SSB=D034.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) OPEN VOL
(2) A host I/O is issued to P-VOL of a TC Sync pair or HAM pair.
(3) The pair status is PAIR or COPY.
(4) Host I/Os concentrate on the neighboring block area.
(5) The following (a) or (b) occurs.
(a) ECC group where the VOL belongs to is in correction copy
processing.
(b) One side of CM or SM of MCU where the VOL belongs to is
blocked.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy
Changed Part DKCMAIN

HDS Confidential 79 of 107


235 Abend of LDEV quick format with SSB=1548 output
Phenomena When LDEV quick format was executed, SSB=1548 was output and the
format might end abnormally.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) HDD is SATA-E.
(2) Emulation type is 3390-A (without DP-VOL attribute)
(3) Cache is overloaded (Write Pending rate is 60% or higher).
(4) LDEV quick format is executed.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

236 Taking longer time for resync operation


Phenomena When group resync was executed for a Mainframe Sync CTG and then
group suspend was executed before the internal processing of the resync
was completed, the following occurred.
(1) The resync operation took time.
(2) The pair status did not change to Suspend.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) True Copy for Mainframe
(2) Sync CTG
(3) Group resync is executed.
(4) Group suspend is executed while some pairs in Suspend status exist in
the group after the above group resync operation.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe
Changed Part DKCMAIN

237 Incorrect indication of pool VOL for LDEV


Phenomena After pool shrink was executed for an LDEV (pool VOL), the LDEV was
deleted on the Pools window but LDEV window continued to show that
the LDEV was a pool VOL.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Shrink Pool is executed but not completed.
(2) For LDEVs other than the above Shrink Pool target LDEV, one of the
following maintenance operations is performed.
- LDEV installation
- LDEV removal
- PDEV installation
- PDEV removal
- System option setting change
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Dynamic Provisioning
Changed Part DKCMAIN

HDS Confidential 80 of 107


238 Failure of login command with error message
Phenomena During login processing, if an MP failure occurred, a login command of
RAID Manager failed and a RAID Manager command error message,
[EX_ENAUTH] Authentication failed with User, appeared.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when one of the following conditions are met.
(1) Communication between SVP and DKC is disabled due to an MP
failure and so on.
(2) Login and logout of SMIS are executed many times.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

239 Continued SSBs output after FCv2 relationship creation


Phenomena When FCv2 relationship was established while a PIN failure occurred in a
VOL to be used as FCv2 S-VOL, SSB=9C1D and AE63 were
continuously output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe VOL
(2) A PIN failure occurs in a VOL to be used as FCv2 S-VOL and then
FCv2 relationship is created.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Flash Copy version2
Changed Part DKCMAIN

240 XRC session suspend with SSBs output after CHK1 and CHK3
Phenomena During an XRC operation, CHK1 and CHK3 occurred, SSB=65EA,
65EB and 65EC were output, and the XRC session was suspended.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe
(2) Compatible XRC
(3) CHK1 and CHK3 occur during RD RECORDSET command
processing on XRC MCU.
(The problem does not occur by WCHK1)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible XRC
Changed Part DKCMAIN

HDS Confidential 81 of 107


241 Failure of cache maintenance during CFW I/O
Phenomena During CFW I/O processing, if cache maintenance (installation, removal,
replacement) was performed while the cache was overloaded, the cache
maintenance might fail.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CFW I/O is issued from Mainframe host.
(2) Cache is overloaded.
(3) Cache maintenance (installation, removal, replacement) is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

242 Failure of micro-program exchange


Phenomena Micro-program exchange failed. (SVP message SMT2433 E)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Version before exchange is earlier than 70-02-03-00/00 (before V02).
(2) The version exchanged with the above is 70-02-03-00/00 or higher
(V02 and higher).
(3) The combination of CHA configuration and selected reboot type is
either one of (a) or (b).
(a) CHA is BASIC only, the selected type is 1/4, 1/8, or By One.
(b) CHA is OPTION1 and later, and the selected type is By One.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

243 Extremely large response time and transfer length


Phenomena When RMF (Resource Measurement Facility) was used with ESS option
specified on an IBM host, the values of response time and data transfer
length which were displayed on [PPRC SEND] and [PPRC RECEIVE] of
[ESS LINK STATISTICS] were extremely large.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) RMF is used with ESS option specified.
(2) Initial copy or update copy of TC/TCz pair is in process.
(3) During the measurement of (1), the integrated value of data transfer
length of a port used for TC pair M-R connection exceeds 4 bytes (2,047
Gbytes) or the integrated value of data transfer time exceeds 4 bytes
(4,294 seconds).
* The problem occurs only at the time when each integrated value
exceeds 4 bytes. Once the value has exceeded 4 bytes, the problem does
not occur until the exceedance occurs again.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe
Changed Part DKCMAIN

HDS Confidential 82 of 107


244 SVP message display when Auto Plan tab opens
Phenomena When Auto Plan tab on Volume Migration window was opened, SVP
message [5205 6023] appeared.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) No parity group on DKC is mounted.
(2) Auto Plan tab on Volume Migration window is opened.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Volume Migration
Changed Part SVP

245 Wrongly returned setting of SSID or cache mode


Phenomena Phenomenon1
SSID setting (raidcom modify ldev) made from RAID Manager returned
to the previous setting.
Phenomenon2
Cache mode setting of external VOL (raidcom modify external_grp)
made from RAID Manager returned to the previous setting.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
Phenomenon1
(1) An LDEV whose provisioning type is BASIC is created or deleted
from Storage Navigator.
(2) SSID setting is performed from RAID Manager during the time period
from execution to completion of the above operation.

Phenomenon2
(1) An LDEV whose provisioning type is BASIC is created or deleted
from Storage Navigator.
(2) Cache mode setting of external VOL is performed from RAID
Manager during the time period from execution to completion of the
above operation.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category RAID Manager
Changed Part DKCMAIN

246 SSB=9680 output by Withdraw during FC background copy


Phenomena During FC background copy, if Withdraw (DDSW=NO) was executed,
pair was deleted but SSB=9680 might be output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) Background copy is in process.
(3) Withdraw (DDSW=NO) is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 83 of 107


247 Failure of pair deletion and command reject
Phenomena During FC background copy, if Withdraw (DDSW=NO) was executed,
the pair was not deleted and commands to the VOL were rejected.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe
(2) Background copy is in process.
(3) Withdraw (DDSW=NO), Restore, or Fast Reverse Restore is
executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

248 SSBs when LDEV deletion command is sequentially executed


Phenomena LDEV command (raidcom delete ldev) was sequentially executed from
RAID Manager or CLI, SSB=B9CD and B904 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when "raidcom delete ldev" command is sequentially
executed for the same LDEV from RAID Manager or CLI.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

249 Failed TC pair creation in DKC configuration


Phenomena When DKC configuration contained external connection, TC pair creation
after MP PCB failure might fail.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe VOL
(2) TC pair creation is executed after MP PCB failure occurs.
(3) DKC configuration contains external connection (regardless of Open
or Mainframe)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

250 Port offline occurrence during hazard test


Phenomena During a hazard test from HP-UX, port offline occurred. "Fatal error" was
reported on the host.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open connection.
(2) Operating rate is over 50%.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 84 of 107


251 Unable to return LS_ACC and SSB output
Phenomena After CHK2 occurrence, PLOGI was received from a host, but LS_ACC
could not be returned and SSB=BC29 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A LOGO command is received from a host connected to a FCoE port.
(2) Reset occurs to release resource.
(3) A PLOGI command is received from the host while the reset is sent.
(4) By the reset, IOCB (Login/Logout Port IOCB) for resource release is
issued to a protocol chip.
(5) Because of the resource release IOCB issued to the protocol chip, the
resource of PLOGI received from the host is released.
(6) Due to the release of (5), LS_ACC of PLOGI cannot be returned,
time-out occurs, and then the job stops.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

252 Link down with SSB=B6C0 after MP failure


Phenomena After an MP failure occurred, link down occurred and SSB=B6C0 was
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) MP is blocked.
(2) Resource release is notified to a protocol chip.
(3) ABTS is received from a host.
(4) BA_ACC of ABTS is issued to the host.
(5) PLOGI command is received from the host.
(6) LS_ACC of PLOGI is issued to the host but it turns to an error in the
protocol chip.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

253 Frequent output of SSB=9F02 and 9853


Phenomena When the status of SI/CoW Snapshot pair was changing, SSB=9F02 and
9853 were frequently output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) SI P-VOL is used as CoW Snapshot P-VOL.
(2) The SI pair status is PAIR.
(3) The Snapshot pair status is PSUS.
(4) A write I/O is issued to the SI P-VOL and the Snapshot P-VOL.
(5) SPLIT is executed for the SI pair.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Shadow Image
Changed Part DKCMAIN

HDS Confidential 85 of 107


254 Unable to block the failed MP if CHK1B occurs
Phenomena If an MCH-DMA error occurred and CHK1B failure due to another factor
occurred before MP was blocked, the blockade processing for the MP
where the MCH-DMA error occurred was not executed, and SSB=32FD
and 1607 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An MCH-DMA error occurs.
(2) Before MP is blocked, CHK1B due to another factor occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

255 Not collected CHK1C information in LM dump


Phenomena When CHK1C occurred, the CHK1C information was not collected in
LM dump.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when CHK1C occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

256 Incomplete display of serial#


Phenomena When "raidcom get path" was executed from CLI, only 11 digits of
serial# was displayed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) UVM configuration with NEXSAN connected.
(2) "raidcom get path" is executed from CLI.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

257 Failed Volume Migration or unchanged pair status


Phenomena Volume Migration failed and SSB=212B was output, or the status of SI
Quick Restore did not change to PAIR but remained in R-COPY.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when the following conditions (1) and (2), or
only (3) are met.
(1) Volume Migration is executed.
(2) Random read access to migration source VOL
(3) SI Quick Restore is executed for OPEN volume.
* More likely to occur if VOL size or mounted cache capacity is large.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Shadow Image, Volume Migration
Changed Part DKCMAIN

HDS Confidential 86 of 107


258 Incomplete alternate path addition with SSBs output
Phenomena While 2048 external groups were mapped in the same path group, if the
8th path was added as external path addition from CLI (raidcom add
path), alternate paths were only added to 1024 groups out of 2048 groups
and SSB=2E23 and 4303 were output at executing GetCommandStatus.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) The number of alternate paths in a path group is 7.
(2) There are 1025 or more external groups in the same path group.
(3) External path addition is executed from CLI. (raidcom add path)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

259 ESW PCB internal failure with SSB=3250 leading to WCHK1


Phenomena When an ESW PCB internal failure occurred, SSB=3250 was
continuously output and WCHK1 occurred (SIM=3073XY, SSB=1663 or
32FA)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) The storage system is in ready status.
(2) An ESW PCB internal failure occurs. (SSB=3250)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

260 WCHK1 occurrence due to ESW PCB internal failure leading


WCHK1 in all MP
Phenomena When an ESW PCB internal failure occurred (SSB=3250), WCHK1
occurred (SSB=3585).
In the worst case, WCHK1 occurred in all MPs except 1MP in 1DKC.
(SIM=3073XY, SSB=3250 and 3585)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) The storage system is in ready status.
(2) An ESW PCB internal failure occurs (SSB=3250).
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 87 of 107


261 Failure of DKAF micro-program update in configuration
without DKA
Phenomena At micro-program upgrade in a configuration without DKA, if DKAF
was also checked on Micro-program Exchange dialog box and the
upgrading was executed, the operation itself was completed normally, but
[MP Ver. (Curt./FM)] on Version window of SVP Maintenance window
showed abnormality. All the information on [MP Ver. (Curt./FM)] was in
red. Besides, * (asterisk) was added to the end of version of DKAF.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Configuration without DKA
(2) On Micro-program Exchange dialog box, DKAF is checked.
Affected Products/Version DKCMAIN: All SVP: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
SVP: 70-02-53/00
Category Open and Mainframe
Changed Part DKCMAIN, SVP

262 "raidcom get command_status" response


Phenomena Before the completion of asynchronous processing, response of "raidcom
get command_status" was returned.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Multiple commands are executed.
(2) Before the completion of the command executed first, a command
executed later is completed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

263 Abend of DKA replacement/installation or DKA blockade


Phenomena When micro-program downgrade was executed while DKCMAIN was
selected and DKAF was not selected, micro-program consistency of
DKCMAIN and DKAF was not checked, and micro-program downgrade
ended normally. (SVP message=SMT2434i, SSB=1Axx)
After that, the following problem might occur.
(1) DKA replacement ended abnormally.
(2) DKA installation ended abnormally.
(3) After turning power OFF or PS OFF, when the system was activated,
DKA was blocked.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Micro-program downgrade
(2) DKCMAIN is selected.
(3) DKAF is not selected.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 88 of 107


264 FCoE port blockade
Phenomena An FCoE port was blocked and SSB=2120 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence Occurs when Qlogic chip sequentially receives PLOGI over a short time.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

265 Wrong SSB output at CHK3 occurrence


Phenomena When CHK3 due to micro-program failure occurred, SSB=1663 was
output instead of SSB=3585 which was supposed to be output as error
code for WCHK1.
(SIM=3073, SSB=3250 and 1663)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) The storage system is in ready status.
(2) CHK3 accompanied with micro-program failure is detected in micro
processor of MP PCB1, 2, 3, 5, 6 and 7.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

266 Omitted volume identifier field


Phenomena When "raidcom discover lun" was executed from CLI, the field of volume
identifier (E_VOL_ID_C) was omitted when displayed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when "raidcom discover lun" is executed from CLI
in UVM configuration where any of the following devices is connected.

MSA1000, DMX1000, CX600, Symm8830, SUN, EVA, E3000, iStrage,


MSA, STK, Gateway, E8000, E4000, DMX-4, NEXSAN, IFT, Toshiba,
Xiotech, ST6920, S400, ST2540, Evolution II, Ultimate III, DS4700, HP
MSA2000, CX600, IBM SVC, E4000, FUJITSU DX8000, MSA2000G3
or FUJITSU DX400
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 89 of 107


267 Internal logical error when command device is set to LU of
external VOL
Phenomena When command device including User Authentication Device Group
Definition was set for external VOL LU, and logical error occurred.
(Storage Navigator message 01005-00196, SVP message SEC-333E)
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when command device (User Authentication, Device
Group Definition) is set for an external VOL LU.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

268 Host I/O stop with SSB=D034 output


Phenomena When a failure occurred during host I/O processing, the host I/O might
stop and SSB=D034 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a failure occurs during host I/O processing.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

269 No message for error cause at communication failure or


Windows error
Phenomena Phenomenon 1: When a communication failure or Windows error
occurred during SSW replacement, a message (ONL3325E) which just
indicated abnormal processing appeared but an SVP message to show the
cause of error was not displayed.
Phenomenon 2: When a communication failure or Windows error
occurred during MPB installation, a message (ONL0813E) which just
indicated abnormal end appeared but an SVP message to show the cause
of error was not displayed.
Severity (High, Medium, Low) Low
Conditions of Occurrence For phenomenon 1:
The problem may occur when any of the following occurs during SSW
replacement.
(1) A communication failure between SVP and DKC.
(2) A Windows error.

For phenomenon 2:
The problem may occur when any of the following occurs during MPB
installation.
(1) A communication failure between SVP and DKC.
(2) A Windows error.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 90 of 107


270 Abend of YKQUERY from BCM to RCU
Phenomena In UR Mainframe configuration, YKQUERY issued from BCM to RCU
side ended abnormally. (BCM message: 0C9)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator for Mainframe
(2) C/T TIME MODE of BCM Copy Group Attributes is JOURNAL or
ASIS.
(3) System Option Mode530 is set to ON.
(4) An I/O is issued while a URz pair is in DUPLEX status.
(5) YKQUERY is executed from BCM to RCU side.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

271 Unnecessary one-byte space added at the end of PORTs line


Phenomena When "raidcom get ldev" command was executed without - key option,
unnecessary one-byte space was added at the end of the line of PORTs.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) An LDEV is configured with alternate paths from several ports.
(2) Some of the host groups connected with the LDEV in (1) via different
ports have the same host group name.
(3) Raid Manager issues the "raidcom get ldev" command, which
includes a parameter: "PORTs".
(4) When the last Host Group name in the "PORTs" is the same as that in
(2), the problem will occur.
Affected Products/Version DKCMAIN: All
RAID Manager: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
RAID Manager: 01-25-03/11
Category RAID Manager
Changed Part DKCMAIN
RAID Manager

272 Incorrect space included in serial#


Phenomena When any of the following commands was executed from CLI, a space
might be included in serial#.
- raidcom discover lun
- raidcom get path
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UVM configuration with any of the following storages connected.
SUN, FAStT, STK, Gateway, DS4800, Xiotech, NetApp, ST6920, S400,
ST2540, DS4700, DS5000 or IBM SVC
(2) "raidcom discover lun" or "raidcom get path" is executed from CLI.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 91 of 107


273 PA error with SSBs output by Write Track Data command for
cylinders
Phenomena During TC pair resync processing, if a Write Track Data command was
issued from a host to 2 cylinders, a PA error occurred at the data writing
to the second cylinder and SSB=5860 and 6855 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) MF TC Sync
(2) The pair status is Pending Duplex.
(3) A host issues Write Track Data or Write Full Track command.
(4) A write I/O which is multiple track write for cylinders and does not
write data to head# 0x0e is received.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy for Mainframe
Changed Part DKCMAIN

274 Job abend with SSB=673A output at MP-2MC removal


Phenomena In RAID700 and RAID600 configuration, when MP-2MC on RAID700
was removed, a job being executed (Write Full Track command) ended
abnormally and SSB=673A was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe TC Sync
(2) Write Full Track command is executed.
(3) The write command processing detects exclusive bit of write slot and
an incomplete update copy is stopped. (SSB=8631)
(4) Write Full Track command is created using data chain.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

275 CHK2 occurrence in MCU with SSBs output


Phenomena In pair configuration with EAV and DP coexisted, when MP replacement,
DKA replacement or MP installation/removal was performed on MCU or
RCU, CHK2 occurred in the MCU and SSB=B21B, 8BEC, 8BEA, 3570,
B2FF and B2C8 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe TC Sync
(2) Write Track Data command
(3) Multiple track write
(4) Temporary abnormal end occurs in copy job (it occurs by path failure
(including micro-program exchange), CHK2 or receiving attention)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 92 of 107


276 Failure suspension with SSB=8FCC after all MPs blockade by
WCHK1
Phenomena While a UR pair was in initial copy processing, if all MPs of JNL
ownership PCB where the pair belonged to were blocked on MCU due to
WCHK1, SSB=8FCC was output and the pair was suspended by failure.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR pair initial copy processing.
(2) All MPs of a JNL ownership PCB to which the pair belongs are
blocked due to WCHK1.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

277 Wong SIM output


Phenomena Even though, SVP-BASIC JP1 was placed, SIM=BFE3A2 for dual SVP
setting failure was output.
* The SIM is supposed to be output when there is an error in SVP high
availability kit setting.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when one of the following operations is executed
while SVP-BASIC JP1 is placed.
(1) SVP high availability kit setting without setting SVP-OPTION
(2) SVP high availability kit setting release while SVP-OPTION is set.
Affected Products/Version SSVP: All
Fixed Product/Version SSVP: 70-02-53/00
Category Open and Mainframe
Changed Part SSVP

278 LDEVs wrongly created with the same LBA start point
Phenomena If Install CV (raidcom add ldev) was sequentially executed more then 3
times from CLI, LDEVs with the same LBA start point might be created.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when Install CV is executed from CLI under the
conditions below.
(1) The LBA start point of the second LDEV is smaller than that of the
first LDEV.
(2) The LBA start point of the third LDEV is smaller than that of the first
LDEV.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 93 of 107


279 Failure suspension with SSB=BBAC output
Phenomena In OPEN MxN or Mainframe MxN configuration, if I/O load was high, a
JNL on MCU became full, SSB=BBAC was output and failure
suspension occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator or Universal Replicator for Mainframe
(2) OPEN MxN or Mainframe MxN configuration
(3) An I/O is executed while a UR pair is in DUPLEX status.
(4) JNL usage on RCU is 512MB or more.
(5) Operating rate of the Initiator port on RCU is 40% or more.
(6) Write pending rate on RCU is 25% or more.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

280 Invalid number of issued frames with SSB=B70A output at


path creation
Phenomena In N-port connection, when path between CUs shared by TC/UR was
created, the number of issued frames became invalid and SSB=B70A was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Fabric OFF/Point to Point connection
(2) TC/UR/external configuration
(3) Port attribute MCU/external
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

281 START PENDING occurrence in host after busy report


Phenomena During I/O processing in multiple hosts connection, Busy was reported to
a specific host and START PENDING (SSB=1603) occurred in the host.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Multiple Mainframe hosts connection
(2) A path is connected to port#0.
(3) Busy is reported to a host during I/O processing from multiple hosts.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 94 of 107


282 Temporary 90% of MP operating rate
Phenomena During TC pair initial copy processing, MP operating rate on MCU side
might temporary increase to 90%.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TC pair initial copy processing
(2) Initial copy multiplicity is set to 256 or more.
(3) Pair creation of 256 or more volumes is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe
Changed Part DKCMAIN

283 Response failure with SSB=DDA1 at transfer time-out


Phenomena When transfer time-out occurred due to high load, the response could not
be returned temporarily and SSB=DDA1 was output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Target/RCU-Target port
(2) High load environment where transfer time-out or reset frequently
occurs
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

284 Failures of SVP/SN operation and Audit Log Buffer function


Phenomena [Phenomenon1] The following Storage Navigator or SVP operation might
fail. (Operation from SVP: SVP message 2728 W, operation from Storage
Navigator: Storage Navigator message 3305 2015)
- Make Volume
- Volume To Space
- Volume Initialize
- LDEV maintenance blockade

[Phenomenon2] The following function using system disk might be


disabled. (Operation from SVP: SIM=1801-00, operation from Storage
Navigator: Storage Navigator message=8005 65783, 8005 68761)
- Audit Log Buffer function

[Phenomenon3] WCHK1 might occur by the following operations.


(SIM=3073)
- Operations of Phenomenon1
- Enabling the function of Phenomenon2
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when 9 or more system disks are defined.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 95 of 107


285 Delay of restore and increase in JNL usage rate on RCU
Phenomena In configuration where URz S-VOL was also shared by SIz, if an update
I/O was issued to URz P-VOL while SIz was changing to SPLIT, restore
was delayed and JNL usage rate on RCU side increased.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Universal Replicator Mainframe pair.
(2) Shadow Image for Mainframe uses the URz S-VOL.
(3) SIz is changing to SPLIT.
(4) An update I/O is issued to URz P-VOL.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

286 RAID700 SCHIP FW change


Phenomena A drive may be blockaded when SAS Link failure occurred between
DKA and SSW and the drive is accessed through both ports.
Severity (High, Medium, Low) Medium
Conditions of Occurrence SCHIP FW version 07-00-0E
Causes and Updates The version of SCHIP FW is changed to "07-00-10".
SCHIP firmware is modified to improve the response of SCHIP when
accessing through both ports.
Affected Products/Version SCHIP FW: 07-00-0E and higher
Fixed Product/Version SCHIP FW: 07-00-10
Category Open and Mainframe
Changed Part SCHIP FW

287 Abend with SSBs output by ESW removal during I/O


processing
Phenomena During I/O processing to TC pair (P-VOL and S-VOL were DP-VOLs), if
ESW was removed, the job ended abnormally and SSB=5527, 6149 and
5860 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An I/O (write I/O) is issued.
(2) ESW is removed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

HDS Confidential 96 of 107


288 SSB=1548 output on RCU during update I/O to MCU side
Phenomena When an update I/O was issued to URz MCU side, SSB=1548 was output
on RCU side.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) RCU is RAID700.
(2) Universal Replicator for Mainframe pair
(3) An update I/O is issued to MCU side.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

289 Increased processing time and insufficient LM dump


information
Phenomena When an update I/O was issued to URz MCU side, the processing per
JNCB took additional time (14μs) and LM dump information was
insufficient.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) RCU is RAID700.
(2) Universal Replicator for Mainframe pair
(3) Initial copy or I/O to MCU of the pair
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

290 Invalid collected information after SSB output and failure


suspension
Phenomena When SSB=EF40 was output and failure suspension occurred during UR
pair creation, the collected information of SSB=EF40 was invalid.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) RCU is RAID700.
(2) Universal Replicator or Universal Replicator for Mainframe pair
(3) Initial copy or update I/O to MCU of the pair
(4) SSB=EF40 is output.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part DKCMAIN

HDS Confidential 97 of 107


291 Suspend on host side and wrong SSB=1603 output on DKC side
at pair creation
Phenomena In Mainframe environment, at pair creation (initial copy) of TCz, FC,
URz, SIz or VM VOL, suspend occurred on host side and SSB=1603 was
wrongly output on DKC side.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe
(2) TCz, FC, URz, SIz or VM VOL
(3) Pair creation (initial copy)
(4) Online host and offline host coexist.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

292 Host MIH and SSB=7A20 occurrence by cache removal during


host I/O
Phenomena When a cache PCB on MCU was removed during host I/O processing to a
TCz pair, host MIH occurred and then SSB=7A20 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) A host I/O is issued to a TCz pair.
(2) A cache PCB on MCU is removed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

293 SSBs output by forcible S-VOL deletion during I/O processing


Phenomena In configuration where the consistency of TC Sync CTG was guaranteed,
if S-VOL was deleted during I/O processing to Sync P-VOL, SSB=1699,
16A1, 16AD, D030 and D031 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) OPEN VOL
(2) A host write I/O is issued to P-VOL in TC Sync CTG consistency
guaranteed configuration.
(3) Transfer length of a command is 1Kbyte or longer.
(4) The pair status is PAIR or COPY.
(5) S-VOL forcible delete during I/O processing
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy
Changed Part DKCMAIN

HDS Confidential 98 of 107


294 Frequent MIH after setting HMO51 to ON
Phenomena When HMO51 setting was changed from OFF to ON, MIH frequently
occurred and SSB=1602 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Version 70-02-08-00/00 or earlier is used.
(2) Online micro-program exchange is performed.
(3) One of the following operations is performed.
(a) HMO51 setting is changed from OFF to ON during I/O processing.
(b) An I/O is executed after HMO51 setting is changed from OFF to
ON.
Affected Products/Version DKCMAIN: 70-02-08-00/00
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe
Changed Part DKCMAIN

295 FCv2 pair suspend due to slot confliction in highly loaded


environment
Phenomena In highly loaded environment, if TC/SI copy and FCv2 copy to the same
slot conflicted, FCv2 pair might be suspended and SSB=960C was
output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when TC/SI copy and FCv2 copy to the same
slot conflicts in highly loaded environment.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

296 PS status disagreement (SIM)


Phenomena In the system with DKC-1 mounted, if SSVPMN was replaced,
SIM=BFB2A0 (DKC-0 PS status disagreement) and SIM=BFB2A4
(DKC-1 PS status disagreement) might be reported.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Configuration where DKC-1 is mounted
(2) Ready status
(3) SSVPMN PCB is replaced.
Affected Products/Version SSVP: All
Fixed Product/Version SSVP: 70-02-53/00
Category Open and Mainframe
Changed Part SSVP

HDS Confidential 99 of 107


297 Time-out on MCU with SSBs output
Phenomena During I/O processing between MCU and RCU, as a response from the
RCU could not be received correctly, time-out occurred on MCU
(SSB=C861). If the time-out occurred during pair creation, SSB=B90A
and B944 were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) MP PCB basic module CL1 is mounted.
(2) TC/UR configuration.
(3) An I/O is executed for the TC pair.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy, True Copy for Mainframe
Changed Part DKCMAIN

298 MP operating rate over 90%


Phenomena In highly loaded environment with a large number of FC copy
relationships, MP operating rate might become over 90%.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) There are a large number of FC copy relationships.
(2) Highly loaded environment.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

299 Increase in Write Pending rate and incomplete LDEV format


Phenomena The following phenomena might occur.
- Write Pending rate increased.
- LDEV format was not completed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) DP/DT configuration
(2) Normal VOL and pool VOL coexist in a parity group.
(3) LDEV format is executed for the normal LDEV in the above parity
group.
(4) A write I/O is issued to a DP-VOL associated with the pool VOL in
the above parity group.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 100 of 107


300 Job abend due to CM failure
Phenomena When a CM failure occurred, a mainframe job might end abnormally.
(Host message IOS000I, IOS020I)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An I/O is issued to Mainframe VOL.
(2) A CM failure occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

301 Wrongly enabled V-VOL creation


Phenomena V-VOL of OPEN-V creation with cylinder specified from CLI (raidcom
add ldev) was enabled.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when V-VOL of OPEN-V emulation is created with
cylinder specified from CLI. (raidcom add ldev)
Affected Products/Version DKCMAIN: 70-02-07-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Command Control Interface
Changed Part DKCMAIN

302 Failure of rebalance initiation


Phenomena The rebalance initiation was disabled at the following operations.
(1) Pool expansion
(2) Pool shrink
(3) Tier relocation
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An MP PCB is removed in a maintenance operation.
(2) After executing any of the following operations, you will not be able
to execute the same operation again.
(a) Pool expansion
(b) Pool shrink
(c) Tier relocation
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 101 of 107


303 Stopped host I/O after I/O performance degradation and Start
Pending occurrence
Phenomena Due to a CM PCB failure, backend processing occupied the processor for
a long time (40 msec). Because of it, I/O processing performance of
Mainframe host degraded and Start Pending occurred, causing the
Mainframe host I/O to stop.
SSB=1602, 1603 and 1607.
Host message: Start Pending, MIH
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe host I/O is in process.
(2) A cache failure occurs or cache maintenance is performed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

304 Rejected journal volume creation/deletion command with SSBs


output
Phenomena During journal volume creation by CLI command (raidcom add journal),
if journal volume creation was executed by CLI command (raidcom add
journal) while specifying the same journal group#, SSB=2EE4 and 06EA
were output and the command might be rejected.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Journal volume creation or deletion is executed by CLI command
(raidcom add journal/raidcom delete journal).
(2) Journal volume creation or deletion is executed while specifying the
journal group# which is specified in the operation (1).
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

305 Data transfer time-out between host and storage system


Phenomena When a host/TC/UR I/O was executed, data transfer time-out occurred
between the host and storage system and SSB=B6A9, B6AA and DDA1
were output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when a host/TC/UR I/O is executed for a port.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

HDS Confidential 102 of 107


306 Sending incorrect data to host with SSB=BC91 output
Phenomena During I/O processing in FCoE connection, when a read command was
received, the storage system might send incorrect data to a host. In this
case, SSB=BC91 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) A host is connected with FCoE.
(2) While receiving a read command, a host issues reset command.
(3) When the reset target command is stopped, a protocol chip detects
abnormal end.
(4) Internal buffer area which is used by the abend command is used by
another command.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

307 Incorrectly enabled or disabled external VOL/V-VOL


migration
Phenomena On Virtual Partition Manager, DP V-VOL or CoW Snapshot V-VOL
migration by a user without access right to a resource group of the target
LDEV# was enabled or the migration by a user with access right to the
resource group of the target LDEV# was disabled.
Storage Navigator messages: 8505-75015, 8505-75026
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when any of the following conditions is met.
(1) In an environment where an external VOL whose parity group number
is 16384-xxx (xxx is within the range from 1 to 4096) exists, the external
VOL with 16384-xxx is migrated to another CLPR.
(2) In an environment where 64,389 or more DP V-VOLs exist, the
64,390th or later DP V-VOL is migrated to another CLPR.
(3) In an environment where 64,389 or more CoW Snapshot V-VOLs
exist, the 64,390th or later CoW V-VOL is migrated to another CLPR.

Affected Products/Version SVP: 70-02-03/00 and higher


Fixed Product/Version SVP: 70-02-53/00
Category Virtual Partition Manager
Changed Part SVP

308 I/O performance degradation


Phenomena When an I/O was issued to drives of CDEV#:0x0B and later, the I/O
performance degraded by 8KIOPS.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when the following condition is met.
(1) An I/O is issued to drives of CDEV#:0x0B and later.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open and Mainframe
Changed Part DKCMAIN

HDS Confidential 103 of 107


309 MP blockade during Mainframe host I/O processing
Phenomena When a cache failure occurred during I/O processing from a Mainframe
host to TCz/URz/FCv2 pair, an MP might be blocked and SSB=1644 was
output.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) TCz/URz/FCv2 pair
(2) A Mainframe host I/O is in process.
(3) A cache failure occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Mainframe
Changed Part DKCMAIN

310 Output of non-existent host group information


Phenomena Host group information obtained by RMAPI API: dsvp_GetHostGroupInf
the information of host group which did not exist was output as the host
name of "xx-Gyy"(xx=Port Location, yy=Host Group#).
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when the host group IDs are not continuous.
* Host IDs are sequentially assigned from 0 in ascending order, but if
any host group ID is deleted, the ID may not be continuous.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

311 I/O processing stop with SSB=B801 output at pair deletion


Phenomena When a UR pair using LUSE volumes was deleted during I/O processing,
the I/O processing stopped and SSB=B801 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Open
(2) There is a UR pair using an LDEV used for LUSE.
(3) An I/O is executed.
(4) The UR pair is deleted.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Universal Replicator
Changed Part DKCMAIN

312 Application error when creating 256 or more URz pairs


Phenomena 256 or more URz pairs created from CFL, application error might occur.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when 256 or more UR for Mainframe pairs are
created from CFL.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Universal Replicator for Mainframe
Changed Part SVP

HDS Confidential 104 of 107


313 Checkout failure in delta resync configuration
Phenomena In delta resync configuration, even though an LDEV belonging to a
resource group that the user had no permission existed, checkout might
fail.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) UR Delta Resync configuration.
(2) 2,048 or more pairs exist.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Universal Replicator, Universal Replicator for Mainframe
Changed Part SVP

314 Incorrectly enabled JNLG registration and deletion due to no


resource group check
Phenomena When a JNLG was registered or deleted on EXCTG window, resource
group check was not executed, which wrongly enabled a user with no
access right to an LDEV belonging to the JNLG to register or delete the
JNLG to/from the EXCTG.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when a JNLG is registered or deleted on EXCTG
window.
Affected Products/Version SVP: 70-02-03/00 and higher
Fixed Product/Version SVP: 70-02-53/00
Category Universal Replicator for Mainframe
Changed Part SVP

315 Incorrect drive number display on Alerts window


Phenomena When the details of drive-related SIM was displayed on Alerts window,
the drive number in Location was incorrect.
For example, in case of SIM=EF1397, CDEV#/RDEV#=07/17 was
displayed while 03/97 was correct.

SIM=DF0xxx, DF8xxx, DF9xxx, DFAxxx, DFBxxx, EF0xxx, EF1xxx,


EF2xxx, EF9xxx, 43Bxxx, 43Cxxx, 451xxx, 452xxx, 453xxx, 455xxx,
461xxx, 462xxx, 463xxx, 465xxx
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when drive-related SIM is displayed on Alerts
window of Storage Navigator.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Storage Navigator
Changed Part SVP

HDS Confidential 105 of 107


316 Performance degradation due to unnecessary SM access
Phenomena Due to unnecessary SM access during any I/O processing including
random read or random read and write, the performance degraded.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Simplex VOL
(2) A host issues any of random read I/O or random read and write I/Os.
(3) MP operating rate of all MPs is over 80%.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

317 TC pair suspension with SSB=B8ED


Phenomena A TC pair was suspended and SSB=B8ED was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) MCU of a TC Open pair.
(2) CM failure blockade occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category True Copy
Changed Part DKCMAIN

318 Failure of mode change


Phenomena During SVP mode change from Modify to View, if a user logged out
from SVP while mode change button was inactive, the mode could not be
changed from Modify to View after logging into SVP and changing the
mode from View to Modify.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when a user logs out from SVP while mode
change button is inactive during SVP mode change from Modify to View.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-53/00
Category Open and Mainframe
Changed Part SVP

HDS Confidential 106 of 107


319 I/O stop resulted from disabled response to host command
Phenomena During I/O processing from a host connected with FCoE to a TC pair, if
the TC pair was blocked (SUSPEND) due to a link failure between MCU
and RCU, response to the command issued from the host could not be
returned and the I/O stopped.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) FCoE connection
(2) An I/O is issued to TC P-VOL.
(3) The TC pair is blocked (SUSPEND).
(4) Storage system returns Check Condition to the command received
from the host.
(5) After ABTS is received from the host, the same port receives a
command from the host.
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Open
Changed Part DKCMAIN

320 Unable to complete FCv2 processing in highly loaded


environment
Phenomena In highly loaded environment with a large number of FCv2 relationships,
copy processing might not end.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Highly loaded environment with a large number of FCv2
relationships.
(2) Establish or Withdraw is executed.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-54-00/00
Category Compatible Flash Copy V2
Changed Part DKCMAIN

HDS Confidential 107 of 107