Requirements
Siemens Edition or Ultimate Edition
S7-PLCSIM V13/14
Sample Project
Sorting by Height with S7-PLCSIM V13/14 [../sample-s7-plcsim-v13/]
This tutorial gives you step-by-step instructions on how to use Siemens S7-PLCSIM V13/14 to control FACTORY
I/O.
You will start with a template to create a new TIA Portal project. There are speci c templates for either S7-1200 or
S7-1500 PLCs, as well as for different TIA Portal versions.
https://factoryio.com/docs/tutorials/siemens/setting-up-s7-plcsim-v13/ 1/5
19/4/2018 Setting up S7-PLCSIM V13/14 - FACTORY I/O
Warning
In the existing OB1 there is already a Network 1.
Do not delete this network. Otherwise the connection will not work.
1. Select the device and turn on the simulation by pressing Start Simulation.
2. Choose PN/IE (1) as the type of PG/PC interface and on PG/PC interface select PLCSIM S7-1200/S7-1500
(2). Press Start search (3). When scanning completes, select the device (4) and press Load (5).
https://factoryio.com/docs/tutorials/siemens/setting-up-s7-plcsim-v13/ 2/5
19/4/2018 Setting up S7-PLCSIM V13/14 - FACTORY I/O
https://factoryio.com/docs/tutorials/siemens/setting-up-s7-plcsim-v13/ 3/5
19/4/2018 Setting up S7-PLCSIM V13/14 - FACTORY I/O
4. Select a corresponding CPU model for your project on the Model drop-down list (either S7-1200 or S7-1500).
https://factoryio.com/docs/tutorials/siemens/setting-up-s7-plcsim-v13/ 4/5
19/4/2018 Setting up S7-PLCSIM V13/14 - FACTORY I/O
5. Press Esc to return to the main driver window. Now click on CONNECT to connect to the simulator. A
successful connection is indicated by a green icon next to the selected driver, as well as next to the driver
name displayed on the status bar.
https://factoryio.com/docs/tutorials/siemens/setting-up-s7-plcsim-v13/ 5/5