Vous êtes sur la page 1sur 33

ZXSDR R8862A

Macro Remote Radio Unit


Hardware Description

Version: V1.0

ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://support.zte.com.cn
E-mail: 800@zte.com.cn
LEGAL INFORMATION
Copyright © 2018 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason

R1.3 2016-11-30 Updated "5 Indicators"

R1.2 2015-04-23 Optimized all the figures

R1.1 2014-08-20 Updated "1.2 Indicators"

R1.0 2013-10-14 First edition

Serial Number: SJ-20150203110107-041

Publishing Date: 2016-11-30 (R1.3)

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Contents
About This Manual ......................................................................................... I
Chapter 1 External View............................................................................. 1-1
Chapter 2 External Interfaces.................................................................... 2-1
Chapter 3 External Cables ......................................................................... 3-1
3.1 Protective Grounding Cable ................................................................................ 3-1
3.2 DC Power Input Cable ........................................................................................ 3-2
3.3 AC Power Input Cable ........................................................................................ 3-2
3.4 Antenna Feeder Cable........................................................................................ 3-3
3.5 Optical Fiber Cable............................................................................................. 3-3
3.6 AISG/MON Interface Cable ................................................................................. 3-4

Chapter 4 Auxiliary Devices ...................................................................... 4-1


4.1 Junction Box ...................................................................................................... 4-1
4.2 Lightning Protection Box for AC Power Supply ..................................................... 4-4

Chapter 5 Indicators................................................................................... 5-1


Figures............................................................................................................. I
Tables ............................................................................................................ III
Glossary .........................................................................................................V

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


This page intentionally left blank.

II

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


About This Manual
Purpose
This manual describes the hardware units of the ZXSDR R8862A, including the chassis,
auxiliary devices, and external cables.

Intended Audience
This manual is intended for:
l Installation engineers
l Maintenance engineers

What Is in This Manual


This manual contains the following chapters:

Chapter 1, External View Describes the external view of the ZXSDR R8862A.

Chapter 2, External Interfaces Describes the external interfaces of the ZXSDR R8862A.

Chapter 3, External Cables Describes the external cables used for the ZXSDR R8862A.

Chapter 4, Auxiliary Devices Describes the junction box and the lightning protection box for AC
power supply.

Chapter 5, Indicators Describes the indicators of the ZXSDR R8862A.

Related Documentation
The following documentation is related to this manual:
l ZXSDR R8862A Macro Remote Radio Unit Product Description
l ZXSDR R8862A Macro Remote Radio Unit Hardware Installation

Conventions
This manual uses the following conventions.

Italics Variables in commands. It may also refer to other related manuals and documents.

Bold Menus, menu options, function names, input fields, option button names, check boxes,
drop-down lists, dialog box names, window names, parameters, and commands.

Constant Text that you type, program codes, filenames, directory names, and function names.
width

[] Optional parameters.

{} Mandatory parameters.

| Separates individual parameters in a series of parameters.

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Danger: indicates an imminently hazardous situation. Failure to comply will result in
death or serious personal injury.

Warning: indicates a potentially hazardous situation. Failure to comply can result in


death or serious personal injury.

Caution: indicates a potentially hazardous situation. Failure to comply can result in


moderate or minor personal injury.

Notice: indicates equipment or environment safety information. Failure to comply


can result in equipment damage, data loss, equipment performance degradation,
environmental contamination, or other unpredictable results.

Note: provides additional information about a topic.

II

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 1
External View
Figure 1-1 shows an external view of the ZXSDR R8862A.

Figure 1-1 External View of the ZXSDR R8862A

1-1

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

1-2

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 2
External Interfaces
The external interfaces of the ZXSDR R8862A are located at the bottom and on the front
side of the chassis.

External Interfaces at the Bottom of the ZXSDR R8862A Chassis


Figure 2-1 shows the external interfaces at the bottom of the ZXSDR R8862A chassis.

Figure 2-1 External Interfaces at the Bottom

For a description of the external interfaces at the bottom of the ZXSDR R8862A chassis,
refer to Table 2-1.

Table 2-1 Description of the External Interfaces at the Bottom

No. Label Interface Type/Connector

1 AISG/MON AISG equipment interface DB15 connector


MON external monitoring
interface
LMT O&M Ethernet interface

2 GND Protective grounding interface 16 mm2 yellow/green round


terminal

3 ANT1 (TX/RX) TX/RX antenna interface DIN connector

2-1

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

No. Label Interface Type/Connector

4 ANT2 (RX) RX antenna interface DIN connector

5 ANT3 (RX) RX antenna interface DIN connector

6 ANT4 (TX/RX) TX/RX antenna interface DIN connector

External Interfaces on the Front Side of the ZXSDR R8862A Chassis


Figure 2-2 shows the external interfaces on the front side of the ZXSDR R8862A chassis.

Figure 2-2 External Interfaces on the Front Side

2-2

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 2 External Interfaces

For a description of the external interfaces on the front side of the ZXSDR R8862A chassis,
refer to Table 2-2.

Table 2-2 Description of the External Interfaces on the Front Side

No. Label Interface Type/Connector

1 OPT1 Interface for communication LC-type optical interface (IEC 874)


between the RRU and a BBU,
or RRU cascading interface

2 OPT2 RRU cascading interface LC-type optical interface (IEC 874)

3 PWR Power input interface 2-pin customized connector

4 Grounding cable interface for -


AC power supply

2-3

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

This page intentionally left blank.

2-4

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 3
External Cables
This chapter describes the external view and line sequence of the external cables of the
ZXSDR R8862A.
Table of Contents
Protective Grounding Cable........................................................................................3-1
DC Power Input Cable................................................................................................3-2
AC Power Input Cable ................................................................................................3-2
Antenna Feeder Cable ...............................................................................................3-3
Optical Fiber Cable.....................................................................................................3-3
AISG/MON Interface Cable ........................................................................................3-4

3.1 Protective Grounding Cable


Function
The protective grounding cable provides the protective earth for the ZXSDR R8862A.

External View
This cable is a yellow/green cable with a cross-sectional area of 16 mm2, see Figure 3-1.
Two TNR22-8 terminals are crimped on both ends of the cable and fixed with screws.

Figure 3-1 External View

Signal Description

Name Definition Pin (End A) Pin (End B) Wire Color

PE Protective earth - - Yellow/green

Connection
End A is connected to the protective grounding terminal of the ZXSDR R8862A, and end
B to the grounding bar directly.

3-1

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

3.2 DC Power Input Cable


Function
The DC power input cable leads the external DC power supply to the ZXSDR R8862A.

External View
This external view of DC power input cable, see Figure 3-2.

Figure 3-2 DC Power Input Cable External View

Signal Description

Name Definition Wire Color

-48 V -48 V power supply Blue

-48 V RTN -48 V earth Black

Connection
One end is connected to the 2-wire DC socket of the ZXSDR R8862A while the other end
is connected to the external power supply equipment.

3.3 AC Power Input Cable


Function
The AC power input cable leads the external AC power supply to the ZXSDR R8862A.

External
This external view of AC power input cable, see Figure 3-3.

Figure 3-3 DC Power Input Cable External View

Note:

The AC power input cable contains three wires, including one yellow/green grounding wire
connected to the grounding terminal in the O&M cavity.

3-2

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 3 External Cables

Signal Description

Name Definition Wire Color

L 220 V AC live wire Brown

N 220 V AC neutral wire Blue

PE AC input protective earth Yellow/green

Connection
One end is connected to the AC power terminal and the grounding terminal in the ZXSDR
R8862A while the other end is connected to the AC power distribution unit or the lightning
protection box for the AC power supply.

3.4 Antenna Feeder Cable


Function
The antenna feeder cable connects the antenna feeder interface on the ZXSDR R8862A
chassis to the main feeder to transmit and receive radio signals.

External View
The antenna feeder cable is an RF cable with a diameter of 1/2" and resistance of 50 Ω.
Two DIN connectors are installed on both ends of the cable, see Figure 3-4.

Figure 3-4 External View

Connection
End A is connected to the ANT interface of the ZXSDR R8862A while end B is connected
to the main feeder.

3.5 Optical Fiber Cable


Function
In the ZXSDR R8862A system, the optical fiber cable is used for:

l Connecting the RRU to a BBU


l Connecting two cascaded RRUs

3-3

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

External View
There are two optical interfaces in the ZXSDR R8862A: OPT1 and OPT2, supporting LC
type optical interfaces. This external view of the optical fiber is used as a connecting cable
between the RRU and a BBU, see Figure 3-5.

Figure 3-5 Optical Fiber Cables

Connection
When the optical fiber is used as a connecting cable between the RRU and a BBU, one
end of the fiber is connected to the OPT1 interface of the ZXSDR R8862A while the other
end is connected to the optical connector of the BBU.

When the optical fiber is used for RRU cascading, one end of the fiber is connected to the
OPT2 interface of the upper-layer ZXSDR R8862A while the other end is connected to the
OPT1 interface of the lower-layer RRU.

3.6 AISG/MON Interface Cable


Function
The AISG/MON interface cable supplies power for a remote electrical tilt antenna and
provides the RS485 control interface. The AISG/MON interface is at the bottom of the
ZXSDR R8862A chassis.

External View
Figure 3-6 shows an external view of the AISG/MON interface cable.

Figure 3-6 AISG/MON Interface Cable

Connection
One end is connected to the AISG/MON interface of the ZXSDR R8862A while the other
end is connected to the AISG interface/MON output interface of the antenna.

3-4

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 4
Auxiliary Devices
Table of Contents
Junction Box ..............................................................................................................4-1
Lightning Protection Box for AC Power Supply ...........................................................4-4

4.1 Junction Box


Function
For the DC power equipment far from the ZXSDR R8862A, the DC power cable with a
cross-sectional area of 2 × 10 mm2 is used to reduce voltage drop. The ZXSDR R8862A
uses a DC power cable with a cross-sectional area of 2 × 4 mm2 or 2 × 6 mm2. Therefore,
when the remote DC power equipment is connected to the ZXSDR R8862A, a junction box
is used for cable diameter conversion.

External View
Figure 4-1 shows an external view of the junction box.

4-1

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

Figure 4-1 External View

Dimensions
Table 4-1 shows the dimensions of the junction box.

Table 4-1 Dimensions

Item Description

Height × width × depth 233 × 119 × 55


(mm × mm × mm) (excluding the handle and waterproof plug)

Installation Position
The junction box is installed on the ZXSDR R8862A, see Figure 4-2.

4-2

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 4 Auxiliary Devices

Figure 4-2 Installation Position

Cable Connection
Figure 4-3 shows the cable connection of the junction box.

4-3

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

Figure 4-3 Cable Connection

Name Description

Input (IN) DC power cable with a cross-sectional area of 2 × 10 mm2

Output (OUT) DC power cable with a cross-sectional area of 2 × 4 mm2 or 2 ×


6 mm2

4.2 Lightning Protection Box for AC Power Supply


Function
When the ZXSDR R8862A is powered by an AC supply, it is necessary to use the lightning
protection box to have stable alternating current. PIMAC is a model of the lightning
protection box for outdoor AC power supply.

4-4

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 4 Auxiliary Devices

External View
Figure 4-4 shows an external view of the lightning protection box for AC power supply.

Figure 4-4 External View

Installation Position
The lightning protection box is installed on the back of the ZXSDR R8862A, see Figure
4-5.

4-5

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

Figure 4-5 Installation Position

Cable Connections
Figure 4-6 shows the internal and external cable connections of the lightning protection
box.

4-6

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 4 Auxiliary Devices

Figure 4-6 Cable Connections

4-7

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

This page intentionally left blank.

4-8

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 5
Indicators
The indicators on the ZXSDR R8862A panel indicate the operating status of the RRU. The
indicators are located on the front side of the chassis, see Figure 5-1.

5-1

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

Figure 5-1 Indicators on the Panel

For a description of the indicators on the panel, refer to Table 5-1.

5-2

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Chapter 5 Indicators

Table 5-1 Indicator Descriptions

Name Meaning Color Operational Mode

l Lit: power on with fault.


l Slow flashing (1 s on and 1 s off): soft-
ware startup.
l Normal flashing (300 ms on and 300 ms
off): normal system operation and com-
Operating sta-
RUN Green munication between BBU and RRU.
tus indicator
l Fast flashing (70 ms on and 70 ms
off): normal system operation but ab-
normal communication between BBU
and RRU.
l Not lit: Power off or failure.

l Not lit: no internal Hardware Alarm.


ALM Alarm indicator Red
l Lit: internal Hardware Alarm.

l Lit: normal optical fiber link.


l Not lit: No optical signal received in
Status of optical OPT1.
OPT1 Green
interface 1 l Flashing (300 ms on and 300 ms off):
Optical signal received and link syn-
chronized in OPT1.

l Lit: normal optical fiber link.


l Not lit: No optical signal received in
Status of optical OPT2.
OPT2 Green
interface 2 l Flashing (300 ms on and 300 ms off):
Optical signal received and link syn-
chronized in OPT2.

VSWR alarm l Lit green: No alarm occurs.


VSWR Red
indicator l Lit red: An alarm occurs.

l Lit: The RRU has been active with BBU


configuration parameters.
RRU activation l Not Lit : The RRU has not been active
ACT Green
status indicator with BBU configuration parameters or
the radio frequency analysis is on the
network management system.

Note:
No matter the state of the other lights, as long as the RUN is lit or off, it means in a fault
state except during startup for short time lit or off.

5-3

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


ZXSDR R8862A Hardware Description

This page intentionally left blank.

5-4

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Figures
Figure 1-1 External View of the ZXSDR R8862A....................................................... 1-1
Figure 2-1 External Interfaces at the Bottom ............................................................. 2-1
Figure 2-2 External Interfaces on the Front Side ....................................................... 2-2
Figure 3-1 External View........................................................................................... 3-1
Figure 3-2 DC Power Input Cable External View ....................................................... 3-2
Figure 3-3 DC Power Input Cable External View ....................................................... 3-2
Figure 3-4 External View........................................................................................... 3-3
Figure 3-5 Optical Fiber Cables ................................................................................ 3-4
Figure 3-6 AISG/MON Interface Cable...................................................................... 3-4
Figure 4-1 External View........................................................................................... 4-2
Figure 4-2 Installation Position .................................................................................. 4-3
Figure 4-3 Cable Connection .................................................................................... 4-4
Figure 4-4 External View........................................................................................... 4-5
Figure 4-5 Installation Position .................................................................................. 4-6
Figure 4-6 Cable Connections .................................................................................. 4-7
Figure 5-1 Indicators on the Panel ............................................................................ 5-2

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Figures

This page intentionally left blank.

II

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Tables
Table 2-1 Description of the External Interfaces at the Bottom .................................. 2-1
Table 2-2 Description of the External Interfaces on the Front Side ............................ 2-3
Table 4-1 Dimensions ............................................................................................... 4-2
Table 5-1 Indicator Descriptions ................................................................................ 5-3

III

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Tables

This page intentionally left blank.

IV

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential


Glossary
AC
- Alternating Current
AISG
- Antenna Interface Standards Group
ANT
- Antenna
BBU
- Base Band Unit
DC
- Direct Current
LMT
- Local Maintenance Terminal
MON
- Monitor
RRU
- Remote Radio Unit

VSWR
- Voltage Standing Wave Ratio

SJ-20150203110107-041|2016-11-30 (R1.3) ZTE Proprietary and Confidential

Vous aimerez peut-être aussi