Vous êtes sur la page 1sur 1

F01T100

F01T100 Cabinet
Cabinet

Product Parameters
Dimensions (without the battery compartment and
830 mm x 600 mm x 250 mm (H x W x D)
without an enhanced heat dissipation module)
Dimensions (with a 40Ah battery compartment and
1280 mm x 600 mm x 250 mm (H x W x D)
Installation Scenarios without an enhanced heat dissipation module)
Dimensions (with a 20Ah battery compartment and
1080 mm x 600 mm x 250 mm (H x W x D)
without an enhanced heat dissipation module)
Wall, poles, concrete foundation,or elevated platform Dimensions(without the battery compartment and
910 mm x 600 mm x 250 mm (H x W x D)
with an enhanced heat dissipation module)
Battery capacity 40Ah, 20Ah or 12Ah lead-acid battery (one set)

Maximum weight (without/with batteries) 96 kg/148 kg


Highlights Operating environment -33 °Cto +45 °C (solar radiation 1120 W/m²)
With an enhanced heat dissipation module:ETS
300753 Class 4.1E village level
Easy No location limitation for light and small-sized design Noise standard Without an enhanced heat dissipation
deployment Flexible installation for wall- , pole- and concrete- mounted module:ETS 300753 Class 4.1E conservation
Fast deployment for remote ,DC or AC power supply district level
Heat dissipation mode Enclosed self-cooling
Simple Flexible extension for services of 256 users Self-cooling: 48 °C/350 W
evolution Maximum heat dissipation capability
Easy network evolution under copper-optical compatibility Forced cooling: 50 °C/550 W

High Provides up to 40 kA protection capability, built-in hinges, built-in


mounting holes, high burglar-proof performance.
Service Configuration
reliability
Uses IP55 enclosed-type design to effectively isolate external
Configuration 1 DC/AC MA5616 1 DC/AC MA5818
harmful dust or gases that may cause corrosion, so that the service
life of the equipment is at least 24 months longer. Users 256: POTS/ADSL2+/VDSL2 (Supports Vectoring) 96 G.fast
192: VDSL2 (Supports SuperVector)
128: (POTS + ADSL2+)
One-stop One-stop delivery for the device, power, MDF/ODF, and monitoring 192: (POTS + VDSL2)
system without secondary site integration. 192: (POTS + SuperVector)

Configuration 1 DC/AC MA5608T 1 DC/AC MA5800-X2


Maintenance- Has no any air filter. The maintenance manpower is saved by at least
free 80% because the equipment does not require frequent maintenance. Users 32 PON 32 PON
96 P2P 96 P2P

Vous aimerez peut-être aussi