5BB Multi-crystalline

Solar PV Modules –
1500V Series
ASP-7-AAA (AAA=305-335) | 72 Cells | 305-335 Wp

Highlights

More power/m2 compared to industry average

Higher specific energy yield (kwh/kwp) due to


superior cell + module engineering

Superior performance at NOCT andPCT conditions

Superior low light irradiation performance 2


 00w/m2

5BB modules offer better performance against


microcracks compared to 4BB & 3BB modules

Triple EL checking to ensure defect free modules

Reduces installation Reduces transport Reduces land Reduces BOS


costs by 2% costs by 2% costs by 2% costs by 4%

Significant advantages of Adani 5BB multi-crystalline module Current-voltage curve

325
0 1 2 3 4 5 6 7 8 9 10

315 1000W/m2
Power (WP)

Current (A)

305 800W/m2

600W/m2
295 400W/m2

200W/m2
285
0 10 20 30 40 50
Adani – multi-crystalline Industry average
325 WP 320 WP Voltage (V)

Note: Data is based on the comparison of the Adani-72 cells standard multi (325Wp) with industry’s average of 320 Wp module for a scale of 1 MW
installation and cost reduction will vary from site to site.
*As per Bloomberg New Energy Finance (BNEF) latest quarterly report, dated 14th August, 2018
www.adanisolar.com

Technical Data
Dimensions in mm Electrical data – All data measured to STC*
Peak power, (0 ~+ 4.99 Wp)
305 310 315 320 325 330 335
Pmax(Wp)
Maximum voltage, Vmpp (V) 35.55 35.99 36.42 36.85 37.29 37.71 38.15
992±1
947±1 Maximum current, Impp (A) 8.58 8.61 8.65 8.68 8.72 8.75 8.78
Open circuit voltage, Voc (V) 43.79 44.23 44.67 44.97 45.26 46.4 46.5
Short circuit current, Isc (A) 9.09 9.12 9.15 9.18 9.21 9.24 9.27
4-7.5X7.5/2 200±10
DRAIN HOLES
Module efficiency (%) 15.56 15.81 16.07 16.32 16.58 16.84 17.09
135±2

LABEL *STC: Irradiance 1000 W/m², cell temperature 25°C, air mass AM1.5 according to EN 60904-3. Average
efficiency reduction of 4.5 % at 200 W/m² according to EN 60904-1. Except Pmpp, all other parameters
150±10 have a tolerance of +/-3 %, measurement uncertainty <3 %

Electrical parameters at NOCT


1200 mm

Pmax @ NOCT 223.1 227.5 232 238.4 242.5 246.8 252.1


Vmpp @ NOCT 35.02 35.27 35.31 35.37 35.25 35.41 35.53
lmpp @ NOCT 6.37 6.45 6.57 6.74 6.88 6.97 7.10
1960±1
1690±1
1190±1

Voc @ NOCT 41.99 2.422 42.31 42.67 42.77 42.92 43.16


2 - Ø4 lsc @ NOCT 7.07 7.11 7.22 7.33 7.42 7.50 7.60
GROUNDING
HOLE
*NOCT irradiance 800 W/m2, ambient temperature 20°C, wind speed 1 m/sec

Temperature co-efficients (TC) and permissible


operating conditions
980±1

TC of open circuit voltage ( ) -0.31% /°C


8 - 14x9
INSTALLING TC of short circuit current ( ) 0.069 % /°C
HOLE
TC of power ( ) -0.40 % /°C
Maximum system voltage 1500 V (IEC & UL)
16 - 8x3.5
VENT HOLE
NOCT 45°C ± 2°C
Temperature range -40°C to + 85°C

Mechanical data
Length 1960 mm
Width 992 mm
Height 35 mm/40 mm
Packing information Weight 22 Kg (35 mm) / 27 Kg (40mm)
Container 40’HC Junction box IP68
Pallets/Container 24 Cable and connectors 1200 mm length cable, MC4 & Amphenol
compatible connectors
Pieces/Container 744 (35 mm)/648(40 mm)
Application class Class A (Safety class II)
Superstrate High transmittance arc glass
Warranty and certifications
Product warranty** Cells 72 multi-crystalline solar cells; 5 bus bars
12 years of linear power warranty Cell encapsulation Superior dielectric strength & PID resistant EVA

Performance guarantee** Substrate Tri layer backsheet


Power degradation <- 2.5 % in first year Frame Anodized aluminium frame with twin wall profile
<- 0.68 % / year in 2-25 years
Mechanical load test as per IEC & UL 5400 Pa-front; 2400 Pa-back
Approvals and certificates: IEC 61215 Ed2, IEC
Maximum series fuse rating 15 A
61730, IEC 61701, UL 1703, MCS, JET, CEC, CEC-Aus,
IEC 62716, IEC 62782, IEC 60068-2-68, IEC 61853,
IS14286, IS 61730
MSPVL/MDL/PDM/Spec/09

Note:
• The specifications included in this datasheet are subject to change without notice.
• The electrical data given here is for reference purpose only.
• Please confirm your exact requirements with the sales representative while placing
your order. All models sold will be as per MSPVL QAP.
*Caution:
Please read safety and installation instructions ** Warranty:
before using the product. Please read Adani Solar warranty documents thoroughly.
Solar inverters

ABB string inverters


TRIO-27.6-TL-OUTD-S2X-400/JP
27.6 kW

The three-phase commercial inverter High efficiency at all output levels Highlights of the improved design –
offers more flexibility and control to Flat efficiency curves ensure high first time shown at Intersolar 2014
installers who have large installations efficiency at all output levels ensuring − − True three-phase bridge topology for
with varying aspects or orientations. consistent and stable performance DC/AC output converter
across the entire input voltage and − − Transformerless topology
The dual input section containing two, output power range. − − Each inverter is set on specific grid
independent Maximum Power Point codes which can be selected in the
Tracking (MPPT), allows optimal energy This device has an efficiency rating of field
harvesting from two sub-arrays oriented up to 98.2%. − − Detachable wiring box to allow an
in different directions. easy installation
The very wide input voltage range − − Wide input range
The TRIO features a high speed makes the inverter suitable for − − ‘Electrolyte-free’ power converter to
and precise MPPT algorithm for real installations with reduced string size. further increase the life expectancy
power tracking and improved energy and long term reliability
harvesting. In addition to its new look, this inverter
has new features including a special
built-in heat sink compartment and front
panel display system. The unit is free
of electrolytic capacitors, leading to a
longer product lifetime.
ABB string inverters

Additional highlights
−− Integrated string combiner with −− Capability to connect external
different options of configuration sensors for monitoring environmental
which include DC and AC disconnect conditions
switch in compliance with −− Availability of auxiliary DC output
international standards voltage (24V, 300mA)
− − Natural convection cooling for
maximum reliability
− − Outdoor enclosure for unrestricted
use under any environmental
conditions

Technical data and types


Type code TRIO-27.6-TL-OUTD-S2X-400/JP
Input side
Absolute maximum DC input voltage (Vmax,abs) 1000 V
Start-up DC input voltage (Vstart) 430 V (adj. 250...500 V)
Operating DC input voltage range (Vdcmin...Vdcmax) 0.7 x V start...950 V
Rated DC input voltage (V dcr) 620 V
Rated DC input power (Pdcr) 28600 W
Number of independent MPPT 2
Maximum DC input power for each MPPT (PMPPTmax) 16000 W
DC input voltage range with parallel configuration of MPPT at Pacr 500...800 V
DC power limitation with parallel configuration of MPPT Linear derating from max to null [800V≤VMPPT≤950V]
DC power limitation for each MPPT with independent 16000 W [500V≤VMPPT≤800V]
configuration of MPPT at Pacr , max unbalance example the other channel: Pdcr-16000W [400V≤VMPPT≤800V]
Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) 64.0 A / 32.0 A
Maximum input short circuit current for each MPPT 40.0 A
Number of DC inputs pairs for each MPPT 5
DC connection type Tool Free PV connector WM / MC4
Input protection
Reverse polarity protection Protection for inverter only, from current limited source, with max 2 string connected
Input over voltage protection for each MPPT - varistor 2
Input over voltage protection for each MPPT - plug in modular 3 (Class II)
surge arrester (-S2X version)
DC switch rating for each MPPT (version with DC switch) 40 A / 1000 V
Fuse rating (versions with fuses ) 15 A / 1000 V
Output side
AC grid connection type Three Phase 3W+PE or Three phase 3W+N+PE
Rated AC power (Pacr @cosφ=1 ) 27600 W
Maximum AC output power (Pacmax @cosφ=1) 27600 W
Maximum apparent power (Smax) 30000 VA
Rated AC grid voltage (Vac,r) 400 V
AC voltage range 320...480 V
Maximum AC output current (Iac,max) 45.0 A
Contributory fault current 46.0 A
Rated output frequency (f r) 50 Hz / 60 Hz
Output frequency range (fmin...fmax) 47...53 Hz / 57…63 Hz
Nominal power factor and adjustable range >0.995 Adj ± 0.8 with max 30kVA
Harmonic Distortion of Current each <3%, total<5%
AC connection type Screw terminal block, cable gland PG36

2 ABB solar inverters | Product flyer for TRIO-27.6-TL-OUTD-S2X-400/JP


Block diagram of TRIO-27.6-TL-OUTD-S2X-400/JP

IN1A(+)
MPPT 1 Inverter
IN1B(+) (DC/DC) Bulk caps (DC/AC)
+
IN1C(+)
IN1D(+)
*IN1E(+) -S2X version
Line Grid parallel
IN1 IN1 filter relay
IN1A(-)
IN1B(-) L1 L1 L1, S
IN1C(-) L2 L2 L2, S
-
IN1D(-)
L3 L3 L3, S
*IN1E(-)
Current N N,S
reading N

IN2A(+) PE PE
OVP MPPT 2
IN2B(+) monitoring + (DC/DC)
IN2C(+)
IN2D(+)
*IN2E(+)
IN2 IN2
IN2A(-)
IN2B(-)
IN2C(-)
-
IN2D(-)
*IN2E(-)
Current
reading

OVP
monitoring
DC/DC DC/AC
DSP DSP
-S2X version contr. contr.

Current reading
µP
OVP monitoring

Control circuit

PMU_RS485
+ T/R

PT 100
- T/R 1
GND
PT 1000
4...20mA / 0...10V adj PC_RS485
4...20mA / 0...10V adj + T/R

ON/OFF EXT - T/R


GND
Grid standard setting
Service or normal µP Remote control
PC +R
PMU GND

2
AN 1 Alarm
AN 2 N.C
IN mode N.O
C
Wiring box circuit
1 INVERTER
2 WIRING BOX

Technical data and types


Type code TRIO-27.6-TL-OUTD-S2X-400/JP
Output protection
Anti-islanding protection Passive, Active
Maximum AC overcurrent protection 46.0 A
Output overvoltage protection - varistor 4
Output overvoltage protection - plug in modular surge arrester 4 (Class II)
(-S2X version)
Operating performance
Maximum efficiency (ηmax) 98.2%
Weighted efficiency (EURO/CEC) 98.0% / 98.0%
Feed in power threshold 40 W
Stand-by consumption < 8W
Communication
Wired local monitoring PVI-USB-RS232_485 (opt.)
Remote monitoring VSN700 Data Logger (opt.)
User interface Graphic display
Environmental
Ambient temperature range -25...+60°C /-13...140°F with derating above 45°C/113°F
Relative humidity 0...100% condensing
Sound Power Level in accordance with ISO3741 <53 dB(A)
Maximum operating altitude without derating 2000 m / 6560 ft
Physical
Environmental protection rating IP 65
Cooling Natural
Dimension (H x W x D) 1061 mm x 702 mm x 292 mm
Weight 65 kg inverter + 15 Kg wiring box
Mounting system Wall bracket
Safety
Isolation level Transformerless
Remark. Features not specifically listed in the present data sheet are not included in the product

Product flyer for TRIO-27.6-TL-OUTD-S2X-400/JP | ABB solar inverters 3


Efficiency curves of TRIO-27.6-TL-OUTD-S2X-400/JP
100

99

98

97
Efficiency [%]

96

95

BCD.00578 Rev. B EN 27.11.2014


94

93
500 Vdc
92
620 Vdc
91 800 Vdc

90
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

% of Rated Output Power

Support and service For more information please contact © Copyright 2014 ABB. All rights reserved.
ABB supports its customers with your local ABB representative or visit: Specifications subject to change without notice.

dedicated, global service organization


in more than 60 countries and strong www.abb.com/solarinverters
regional and national technical partner
networks providing complete range of www.abb.com
life cycle services.