Académique Documents
Professionnel Documents
Culture Documents
com
Warranty.
A copy of the specific warranty terms applicable to your Raisecom product and replacement parts
can be obtained from Service Office.
All rights are reserved. No part of this document may be photocopied, reproduced, or translated to
another language without the prior written consent of Raisecom Technology Co., Ltd. The
information contained in this document is subject to change without notice.
Copyright Notices.
No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any
means, electronic or mechanical, including photocopying and microfilm, without permission in
Writing from Raisecom Technology Co., Ltd.
Trademark Notices
Microsoft Corporation.
Contact Information
Technical Assistance Center
The Raisecom TAC is available to all customers who need technical assistance with a Raisecom
product, technology, or, solution. You can communicate with us through the following methods:
Address: Building 2, No. 28 of the Shangdi 6th Street, Haidian District, Beijing 100085
Tel: +86-10-82883305
Fax: +86-10-82883056
You can access the most current Raisecom product information on the World Wide Web at the
following URL:
http://www.raisecom.com
Feedback
Comments and questions about how the ISCOM5508 device works are welcomed. Please review the
FAQ in the related manual, and if your question is not covered, send email by using the following
web page:
http://www.raisecom.com/en/contact-us.html.
If you have comments on the ISCOM5508 specification, instead of the web page above, please send
comments to:
export@raisecom.com
Relevant Manuals
ISCOM5508 Configuration Guide
Organization
This manual is an introduction of the main functions of ISCOM5508. To have a quick grasp of the
using of the ISCOM5508, please read this manual carefully. The manual is composed of the
following chapters.
Chapter 2 Components
This chapter introduces ISCOM5508 components appearance, size, version description and
classification description.
Appendix B Acronyms
General Safety Instructions
The following instructions serve as a general guide for the safe installation and operation of
telecommunications products. Additional instructions, if applicable, are included inside the manual.
Safety Symbols
This symbol may appear on the equipment or in the text. It indicates potential safety
hazards regarding product operation or maintenance to operator or service personnel.
Danger of electric shock! Avoid any contact with the marked surface while the
product is energized or connected to outdoor telecommunication lines.
Protective earth: the marked lug or terminal should be connected to the building
protective earth bus.
Some products have terminals which are permanently protective earthing conductors.
Please be sure well connected to earthing before equipment connected to supply.
Some products may be equipped with a laser diode. In such cases, a label with the
laser class and other warnings as applicable will be attached near the optical
transmitter. The laser warning symbol may be also attached.
Please observe the following precautions:
• Before turning on the chassis with optic module, make sure that the fiber optic
cable is intact and is connected to the transmitter.
• Do not attempt to adjust the laser drive current.
• Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam.
• The use of optical devices with the equipment will increase eye hazard.
• Use of controls, adjustments or performing procedures other than those specified herein, may
result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
Always observe standard safety precautions during installation, operation and maintenance of this
product. Only qualified and authorized service personnel should carry out adjustment, maintenance
or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by
either the operator or the user.
Some products have more than one power supply cord. Disconnect 2 power supply cords before
servicing to avoid electric shock.
Before operating modules in the electricity conditions, please be noticed that optical modules shall
be connected with optical fiber wires or shield with optical module cover for fear that laser light
harms to operator’s eyes.
This chapter introduces ISCOM5508 device location, appearance and physical parameters.
Overview
Appearance and slot position
Physical parameters
1.1 Overview
ISCOM5508 device belongs to the next generation of small-capacity, 1U card EPON OLT products,
mainly facing the industrial customers and providing rich features and flexible networking modes so
as to meet low-density, long-distance optical fiber access requirements.
Could be used together with ONU (Optical Network Unit) as EPON (Ethernet Passive
Optical Network) OLT (Optical Line Terminal) in system.
Meet FTTH (Fiber To The Home), FTTB (Fiber To The Building) and FTTx networking
requirements.
Support the automatic collection of electrical network information and building demands of
intelligence community.
Support single fiber Triple Play service.
Support radio and television networks bidirectional transformation (EPON + EOC)
networking requirement.
Provide high-bandwidth, long-distance access to solve small and medium-scale optical fiber
access problem of.
ISCOM5508 device can be installed in the following scenes:
ETSI 600mm rack
19-inch 450mm rack
19-inch 600mm rack
Open rack
Work bench
Note: User needs to order the bracket applicable to 600mm rack when installing chassis to 600mm
rack.
1
www.raisecom.com User Manual
2
www.raisecom.com User Manual
Rate 50Hz/60Hz
3
www.raisecom.com User Manual
Chapter 2 Components
This chapter introduces ISCOM5508 components appearance, size, version description and
classification description.
Overview
Master control board-ISCOM5508
4 EPON interface subcard-EP4
AC power module-RPA0601
DC power module-RPD0601
Fan module-FANS306
2.1 Overview
2.1.1 Components classification
ISCOM5508 device components can be divided into 4 classifications according to the purposes:
Master control board
EPON interface subcard
Power module
Fan module
ISCOM5508 decvice components classification description is shown in the table below.
Master control board ISCOM5508 Control, manage, converge and switch subcard
4
www.raisecom.com User Manual
5
www.raisecom.com User Manual
Note: For different components have different layout, the location of hardware information labels
may be different, please take a close look.
6
www.raisecom.com User Manual
The information description in hardware information label is shown in the table below.
Label Description
2.2.2 Appearance
ISCOM5508 master control board can only be placed in Slot1, as shown in the figure below.
2.2.3 Interface
There are 12 interfaces on ISCOM5508 master board panel. The interface types and purposes are
shown in the table below.
7
www.raisecom.com User Manual
Attribute Description
Attribute Description
In GE uplink interface, 10/100/1000 BASE -T standard RJ45 electrical interface attribute is shown in
the table below.
Attribute Description
Network protocol IP
8
www.raisecom.com User Manual
Note: Please refer to Chapter 4 Small Form-Factor Pluggable for the detail introduction of
1000BASE-X, 1000BASE-PX20-D and 1000BASE-PX20-D-M optical module.
2.2.4 Indicators
There are 16 indicators on master board panel of ISCOM5508, 6 of them are RJ45 interface
indicators. The definition of indicators is shown in the table below.
Weight: 0.7 kg
Power Consumption: 33W
9
www.raisecom.com User Manual
2.3.2 Appearance
EP4 subcard can be plugged at Slot 2 or Slot 3, as shown in the figure below.
2.3.3 Interfaces
There are 4 interfaces on EP4 subcard panel. The interface types and purposes are shown in the table
below.
PON 1/2/3/4 PON SFP Service downlink The available optical module types:
interface
1000BASE-PX20-D
1000BASE-PX20-D-M
Note: Please refer to Section 4 Small Form-Factor Pluggable for the detail introduction of
1000BASE-X, 1000BASE-PX20-D and 1000BASE-PX20-D-M optical module.
2.3.4 Indicators
There are 5 indicators on EP4 subcard panel. The indicators description is shown in the table below.
Weight: 0.3 kg
Power Consumption: 13 W
10
www.raisecom.com User Manual
Providing 110V/220V AC power supply access, redundant power supply for backup.
In support of hot-swapping.
The hybrid application of DC power supply and AC power supply is available.
In support of over-high or over-low voltage detection.
2.4.2 Appearance
RPA0601 power module can be plugged at power module slot, as shown below.
2.4.3 Interfaces
RPA0601 power module only has 1 interface. The interface type and purpose are shown as below.
2.4.4 Indicators
There are 3 indicators on RPA0601 power module panel. The description is shown as below.
11
www.raisecom.com User Manual
2.5.2 Appearance
RPD0601 power module can be divided into two different specifications according to access power
supply type:
RPD0601-48S12: access standard -48V DC voltage.
RPD0601-24S12: access standard +24V DC voltage.
RPD0601 power module can be plugged at power module slot, as shown below.
12
www.raisecom.com User Manual
2.5.3 Interfaces
There is 1 interface on RPD0601-48S12 power module panel. The interface type and purpose are
shown as below.
Grounding interface
There is 1 interface on RPD0601-24S12 power module panel. The interface type and purpose are
shown as below.
Grounding interface
2.5.4 Indicators
There are 3 indicators on RPD0601 power module panel. The description is shown as below.
13
www.raisecom.com User Manual
Weight: 0.6 kg
Rated voltage :
RPD0601-24S12: +24V.
RPD0601-48S12: -48V.
Voltage range:
RPD0601-24S12: +18V~+36V.
RPD0601-48S12: -36V~-72V.
2.6.2 Appearance
FANS306 fan module can only be plugged at FAN module slot of ISCOM5508 device, as shown
below.
14
www.raisecom.com User Manual
2.6.3 Indicators
There are 2 indicators on FANS306 module panel. The description is shown as below.
Weight: 0.3 kg
15
www.raisecom.com User Manual
Note: Optical fiber connector type and cable length are depended on project site situation.
3.1.2 Appearance
LC/PC fiber connector appearance used by ISCOM5508 device is shown as below.
User doesn’t need to rotate when plugging in and pulling out LC/PC fiber connector, the specific
operations are shown as below:
16
www.raisecom.com User Manual
When plugging fiber in, aligning optical interface with fiber head and plugging it in with
suitable strength.
When pulling fiber out, pressing the clip connector and push the plug in a little, and then pull
the fiber out.
Appearance of SC/PC fiber connector is shown as below.
User doesn’t need to rotate when plugging in and pulling out SC/PC fiber connector, the specific
operations are shown as below:
When plugging fiber in, aligning optical interface with fiber head and plugging it in with
suitable strength.
When pulling fiber out, pressing the clip connector and push the plug in a little, and then pull
the fiber out.
Appearance of FC/PC fiber connector is shown as below.
User doesn’t need to rotate when plugging in and pulling out FC/PC fiber connector, the specific
operations are shown as below:
When plugging fiber in, aligning fiber head to optical interface carefully, don’t damnify the
inner tube inside optical interface, rotate screw clockwise when the fiber touches bottom and
then tighten optical interface.
When pulling fiber out, contrarotate the screw at first, pull the fiber out when screw is loose
enough.
17
www.raisecom.com User Manual
3.2.2 Appearance
Network cable appearance is shown as below.
Item Description
Pins 8-pin
EIA/TIA 568A
EIA/TIA568 B
These two standard pin arrangements is shown as below.
18
www.raisecom.com User Manual
2 Green
3 Orange/White
4 Blue
5 Blue/White
6 Orange
7 Brown/White
8 Brown
2 Orange
3 Green/White
4 Blue
5 Blue/White
6 Green
7 Brown/White
8 Brown
According to EIA/TIA standard, the frequently-used ISCOM5508 device Ethernet cable contains two
types:
Straight-through Ethernet cable (Both RJ45 crystal heads are EIA/TIA 568B pin
arrangement)
Cross-over Ethernet cable (One side RJ45 crystal head is EIA/TIA 568B pin arrangement, the
other side is EIA/TIA 568A pin arrangement)
100M/1000M straight-through network cable connection table is shown as below.
19
www.raisecom.com User Manual
20
www.raisecom.com User Manual
3.3.2 Appearance
Configuration cable connector used by ISCOM5508 is DB-9 connector and RJ45 connector, as
figure shows below.
21
www.raisecom.com User Manual
Item Description
Length 2m
3.4.2 Appearance
DC power cable contains DC connector and coaxial-cable, the appearance shows as below.
22
www.raisecom.com User Manual
Item Description
Connector DC connector-3Pin-head/UL/RoHS
ISCOM5508 uses different AC power cables according to different power cord standards in different
regions.
3.5.2 Appearance
European french mode three-plug connector and receptacle are shown as below.
Item Description
Item Description
Length The cable length D is made based on the cutomer’s requirement. For
example: the customer needs 2m cable, then the cable name is USA
standard three-plug-10A/250V-2m/RoHS.
3.6.2 Appearance
ISCOM5508 device grounding cable contains OT terminal and coaxial-cable, as shown in the figure
below.
24
www.raisecom.com User Manual
Item Description
25
www.raisecom.com User Manual
This chapter introduces the small form-factor pluggables used by ISCOM5508 device.
1000M SFP optical module
PON SFP optical module
4.1.2 Label
The label is sticked at the bottom of optical module, as shown in the figure below. User can view
optical module model from the label.
Model Description
26
www.raisecom.com User Manual
Model Description
S1 Transmission distance:
D Digital diagnostic interface, the optical module has digital diagnostic function
01 Manufacture ID
21CFR (J) Comply with U.S. federal regulations on the quality system
Attribute Description
Connector LC/PC
27
www.raisecom.com User Manual
Attribute Description
28
www.raisecom.com User Manual
4.2.2 Label
The optical module type supported by ISCOM6800 EPON service interface:
1000BASE-PX20-D
1000BASE-PX20-D-M
The label is sticked at the bottom of optical module, as shown in the figure below. User can view
optical module model from the label.
Model Description
03 Manufacture ID
21CFR (J) Comply with U.S. federal regulations on the quality system
Parameter Index
29
www.raisecom.com User Manual
Parameter Index
Rx sensitivity -29dBm
Parameter Index
Rx sensitivity -29dBm
30
www.raisecom.com User Manual
All types of indicators on ISCOM5508 device chassis and components are shown as below.
31
www.raisecom.com User Manual
The weight and power consumpation table of ISCOM5508 device chassis and components are shown
as below.
Components Description
Weight 0.7kg
ISCOM5508
Power consumption 33W
Weight 0.3kg
EP4
Power consumption 13W
Weight 0.6kg
RPA0601
Power consumption 0.4W
Weight 0.6kg
RPD0601
Power consumption 0.4W
Weight 0.3kg
FANS306
Power consumption 1.6W
Note:
Standard configuration contains: chassis, ISCOM5508 mainboard, 2 power modules and 1
fan module.
Fullload configuration contains: chassis, ISCOM5508 mainboard, 2 EP4 subcards, 2 power
modules and 1 fan module.
32
www.raisecom.com User Manual
Appendix A Glossary
B
Cable to connect device to ground, usually it is co-axial cable in yellow and
Grounding cable
green.
Label Signs for cable, chassis and warnings.
D
Single mode fiber Only a single mode can be transmitted in one fiber.
Multi-mode fiber Multi-mode can be transmitted in one fiber.
E
ETSI 600 Chassis with width of 600mm, deep of 600mm, compliant to ETSI
standard chassis standard.
G
Small parts at the side of chassis, being used to install the chassis into
Brackets
device rack.
I
IEEE The Institute of Electrical and Electronics Engineers.
International Telecommunication Union Telecommunication
ITU-T
Standardization Sector.
J
4 levels for laser products security in usual, level 1 with the safest laser,
Laser security
power is usually limited at 1mW, which will neither cause fire nor generate
level
harmful radiate.
P
PWE3 Pseudo-Wire Emulation Edge to Edge.
Q
Communication link can transmit and receive data at the same time from
Full-duplex
both directions.
33
www.raisecom.com User Manual
R
Asynchronous transmission mode, no handshaking signal, point-to-point
RS232 communication with other station RS232 or RS422, transparent
transmission, speed up to 19.2kbit/s.
U
Unit of dimension, U is short for unit, take 44.45mm as basic unit, namely
1U
1U=44.45mm.
Z
The auto negotiation procedure is: the port at one site adapts its bit rate and
Auto-negotiation
duplex mode according to the bit rate and duplex mode.
34
www.raisecom.com User Manual
Appendix B Acronyms
Numerics
35
www.raisecom.com User Manual
RH Relative Humidity
36
Address: Building 2, No. 28 of the Shangdi 6th Street, Haidian District, Beijing Postcode:
100085 Tel: +86-10-82883305 Fax: +86-10-82883056 Email: export@raisecom.com
http://www.raisecom.com