38 kV VCPW-HD/HDR

Vacuum circuit breakers

Unmatched reliability, efficiency


and safety
Features Environmentally friendly
• 38 kV, up to 40 kA, • Free of hazardous SF6 gas
up to 3000 A that contributes to the
greenhouse effect and
• 40 percent smaller than associated climate change
38 kV VCP-W breaker
• Tested and certified in
• Back-to-back accordance with IEEE®
capacitor switching C37.06 and C37.09
• Roll-on-floor design
• Requires 31 percent less Reliability, efficiency
space than the traditional and safety
38 kV VCP-W
• Encapsulated pole units
• Fixed breaker available are sealed from dust and
• Designed to accommodate contaminants, providing
up to six front-access current long, reliable equipment life
transformer C200s per phase • Three distinct positions: Test,
Eaton’s medium voltage breaker • No fan cooling required A Disconnect and Connected
platform features the ANSI-rated 38 kV • Breaker mini module available • Provides valuable space
savings for applications,
VCPW-HD/HDR—our compact solution • Automatic secondaries; allowing VTs to be mounted
to your power management needs. the breaker secondaries are on top of breaker or a
automatically made when two-high design
moved from the Disconnect
to the Test position • Partial discharge-free

Industry-leading vacuum and Versatility


solid insulation technology • Protects transformers,
• Leading the industry for more capacitor banks, motors,
than 80 years in vacuum busbar sections and cables
interrupter innovation • Well-suited for special
• Reliably switches normal environment conditions,
load currents and high-stress such as high altitude, light
fault currents shock, vibration and high
ambient temperature
• Features increased dielectric
strength with solid insulation A At 40 kA, 3000 A breaker requires
that is encapsulated in epoxy fan cooling.
resin material, eliminating live
conductors in the breaker cell
Designed in conjunction with: 38 kV VT module and carriage A 38 kV breaker mini module A Tilt-out fuse unit A
• VT modules and VT carriages • The breaker has three distinct • Tilt-out fuse unit has been
are available in one, two and latched positions: Disconnect, fully tested in accordance
three VT L–L and L–G ground Test and Connect with IEEE C37.20.2
configurations • Front-accessible epoxy spouts • Tilt-out fuse units are
• VT module and carriage are have embedded stress shields available in one-, two- and
designed to accommodate and are designed to allow up three-fuse configurations
single or dual secondary VTs to six standard class C200, • The fuse assembly
or two standard class C200
• VT carriage does not include automatically grounds
and two class C400 current
the VT or fuse, but is designed when it is in the
transformers per phase
to accommodate them Disconnect position
38 kV VT Module • The automatic secondary
• The VT fuse assembly • Tilt-out fuse unit can be
contacts are wired and
automatically grounds when it ordered to accept either
identified with wire markers;
is in the Disconnect position 31.5 kA or 50 kA fuses
10-foot-long wires are then
A All associated modules were tested in coiled for customer use • Tilt-out fuse unit is provided
accordance with IEEE C37.20.2. with padlocking provision
• Fully automatic, padlockable
and mounting of a Type D
primary
KirkT keylock
NNote: Fuses are not supplied
and must be ordered by OEM.

Ratings overview
38 kV VT Carriage Circuit Continuous Interrupting Closed and Latch BIL (Impulse)
Breaker Type Current (A) Current (kA rms) (kA Peak) Withstand kV Peak
38 kV VCPW-HD
380VCPW-HD 16 600 16 42 150
1200 16 42 150
1600 16 42 150
2000 16 42 150
2500 16 42 150
3000 16 42 150
380VCPW-HD 25 600 25 65 150
1200 25 65 150
1600 25 65 150
2000 25 65 150
38 kV Breaker Mini Module
2500 25 65 150
3000 25 65 150
380VCPW-HD 32 600 31.5 82 150
1200 31.5 82 150
1600 31.5 82 150
2000 31.5 82 150
2500 31.5 82 150
3000 31.5 82 150
380VCPW-HD 40 600 40 104 150
1200 40 104 150
Tilt-Out Fuse Unit
1600 40 104 150
2000 40 104 150
2500 40 104 150
3000 FC 40 A 104 150
38 kV VCPW-HDR
380VCPW-HDR 40 3000 40 104 200
A At 40 kA, 3000 A breaker requires fan cooling.

NNote: All breakers have voltage range K-Factor = 1.

VCPW-HDR Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

© 2014 Eaton
All Rights Reserved Eaton is a registered trademark.
Printed in USA
Publication No. PA01301024E / Z15793 All other trademarks are property
November 2014 of their respective owners.