Vous êtes sur la page 1sur 50

Pumps and

Automation 2005
Ty p e s e r i e s i n d ex p. 3
Product portfolio p. 6-7
Overview of applications p. 8-15

Our high standard:


Creating intelligent solutions

We have supplied generations of cus-


tomers worldwide with pumps, valves,
automation products and services. A
company with that kind of experience
knows that success never stands still. It
flows. And the process that makes that
possible is a running partnership bet-
ween developer and user, between pro-
duction and practice.

Partners move more together. We do


everything possible to ensure that our
customers always have access to the
ideal product and system solutions. KSB
is a loyal partner. And a strong one:

• Over 130 years’ experience


• Present in more than 100 countries
• Over 12,000 employees
• More than 100 service centres
worldwide
• Approximately 1500 service specialists
Type series index

for pumps and automation

Amacan K 33 Filtra 27 Omega 38


Amacan P 33 FGD 43
Amacan S 33 PSR 42
Amacontrol 47 Getec / Getecbloc 35 PumpDrive 46
Ama-Drainer-Box 30 PumpExpert 47
Ama-Drainer 301 – 356 29 HGB / HGC / HGD 39
Ama-Drainer 405, 435, 505 29 HGM 39 RDLO 38
Ama-Drainer 80, 100 29 HGM-RO 37 RER 41
Amajet 34 HHD 44 RHD 39
Amaline 34 HPH 20 RHM 42
Amamix 33 HPK 20 RHR / RVR 42
Ama-Porter F / S / ICS 29 HPK-L 20 Rio C 16
Ama-Porter CK Pumping Station 31 Hya-Drive 46 Rio-Eco / Rio-Eco Z 17
Amaprop 33 Hya-Eco 28 Rio / Rio Z 16
Amarex KRT 32 Hyamaster ISB 45 Riotec / Riotec Z 17
Amarex KRT, dry-installed 32 Hyamaster SPS 46 Riotherm 16
Amarex N 32 Hyamat IK, IV, IVP 28 Riotherm C 16
Amarex N CK Pumping Station 31 Hyamat K 28 Riotronic 17
Ama-Sani 30 Hyamat V 28 Riovar / Riovar Z 16
Hyamat VP 28 Rotex 29
BSX-BSF 36 Hya-Rain / Hya-Rain-N 25 RPH 25
Hya-Rain Duo 25 RSR 42
Cervomatic EDP 47 Hya-Solo E / D / DV 27 RVM 42
CHTA / CHTC / CHTD 39 hyatronic K / N 45
Compacta 31 hyatronic S 45 S 100 B / UPA 100 C 36
Controlmatic E 47 hyatronic SP 45 Secochem Ex 24
CPK 22 hyatronic mb 45 Secochem Ex K 24
CPK-D 22 hyatronic MSB / spc 46 Sewatec / Sewabloc 34
CPK-H 22 SEZ / PHZ / PNZ 40
CPKN 22 Ixo 27 Single-pump control system 48
CPKO 22 Ixo RWS 26 SNW / PNW 40
CTN 25 SPY 41
KWP / KWP-Bloc 35
Dual-pump control system 48 KRHA / YNK 39 TBC 44
Trialine 17
Etabloc 19 LCC 44 Trialine Z 18
Etachrom BC 19 LCV 43 Tyachem 23
Etachrom NC 19 LHD 44 Tyachem-Bloc 23
Etaline 18 LSA 43 Tyamagno 24
Etaline PumpDrive 18 LSR 43 Tyamagno-Bloc 24
Etaline Z 18 LUV / LUVA / LUVB 40
Etaline Z PumpDrive 18 UPA 100 C / S 100 B 36
Etamagno SY / SYI / Magnochem 23 UPA 150 S 36
Bloc SY 21 Magnochem-Bloc 23 UPA 200, 200 B, 250 C 36
Etanorm / Etabloc MBH 40 UPA 300, 350 36
PumpDrive 19 MHD 44 UPA Control 48
Etanorm / Etanorm R 19 mini-Compacta 30 UPZ 36
Etanorm GPV / CPV 20 MK / MKY 30
Etanorm SYA / RSY 21 Movitec PumpDrive 37 Vitachrom 38
Etaprime B / BN 35 Movitec VE 27
Etaprime L 35 Movitec V / LHS 37 WBC 43
Etaseco / Etaseco-I 24 Multi Eco 26 WKT / WKTA / WKTB 40
Euro-CPK 21 Multi Eco-Pro 26
Evamatic-Box 31 Multi Eco-Top 26 YNK / KRHA 39
Evamatic-Box ICS 31 Multitec 37

3
Our services:
Dependability at your call

We tailor our services to enable maintain your equipment. So you can


new ways of individually optimizing plan for a future free of unwanted sur-
our products. They underscore our far- prises. And we also provide individual
reaching sense of customer responsibil- on-site training sessions. They ensure
ity. That commitment starts before any that operators can use KSB products and
orders – for example with sound advice systems efficiently and profitably, day in,
on financing options. And it goes far day out.
beyond product arrival. A dependable
partnership with KSB lasts for years. Our Which is how we secure the long-term
services to customers include: value of our customers’ facilities.

• Remote diagnosis
• Revamping
• TPM® (Total Pump Management)
• System engineering
• Advice on life cycle costs
• Financing options
• Teleservice
• Savings potential analysis

Ready where you are. KSB runs more


than 100 service centres around the
world. Some 1500 highly trained KSB
specialists are on call to inspect and

4
Our vision:
Moving more, together

Yesterday: Movement with a Today: Impetus from innovations. Tomorrow: Perspectives for
mission. KSB has spent its long history providing partnerships.
When KSB started business in 1871, our technical innovations that help custom- Lively dialogue with customers has been
pumps got things moving almost over- ers and partners work more successfully a KSB speciality for over 130 years.
night. From the word go, the company than ever. Mutual respect remains its hallmark.
was an enthusiastic pioneer. The motor
of that dynamism was the sense of con- We gear everything we do to the real Our aim is to strengthen this working
tributing to new movement in modern demands of everyday operations. partnership still further. The benefits are
industry. Products, systems, life cycle costs and mutual, too: we profit from practical
That is all history now. But KSB still stays our steadily growing range of services all experience that complements our years
true to its tradition, and continues to put customers and their processes first. of development know-how. And so our
pioneer remarkable technical skills. This relies on our special concentration customers profit from innovative pro-
of activities – from development to sales ducts, systems and services that match
and marketing. their demands with precision and
performance.

Partnership is a value whose products keep their value. So moving more together makes doubly good sense. We look
forward to teaming up.

5
Building Services
Waste Water

Industry

Mining
Energy
Water
Type / Application Type Series Page A Segment

Circulator pumps / Rio / Rio Z 16 ■ ■


hot water service pumps, fixed speed Rio C 16 ■
Riovar / Riovar Z 16 ■ ■
Riotherm C 16 ■
Riotherm 16 ■
Circulator pumps, variable speed Rio-Eco / Rio-Eco Z 17 ■
Riotronic 17 ■
Riotec / Riotec Z 17 ■
In-line pumps with fixed / Trialine 17 ■ ■ ■
variable speed drive Etaline 18 ■ ■ ■
Trialine Z 18 ■ ■ ■
Etaline Z 18 ■ ■ ■
Etaline PumpDrive 18 ■ ■
Etaline Z PumpDrive 18 ■ ■
Standardized / close-coupled pumps, Etanorm / Etanorm R 19 ■ ■ ■ ■ ■
fixed / variable speed Etabloc 19 ■ ■ ■ ■ ■
Etanorm PumpDrive / Etabloc PumpDrive 19 ■ ■ ■ ■ ■
Etachrom BC 19 ■ ■ ■ ■ ■
Etachrom NC 19 ■ ■ ■ ■ ■
Etanorm GPV / CPV 20 ■ ■ ■ ■ ■
Hot water pumps HPK-L 20 ■ ■ ■ ■
HPK 20 ■ ■ ■ ■
HPH 20 ■ ■ ■ ■
Hot water / thermal oil pumps Etanorm SYA / RSY 21 ■ ■ ■
Mag-drive thermal oil pumps Etamagno SY / SYI / Bloc SY 21 ■ ■
Standardized chemical pumps Euro-CPK 21 ■ ■ ■
CPK 22 ■ ■ ■
CPKN 22 ■ ■
CPK-H 22 ■ ■
CPK-D 22 ■ ■
CPKO 22 ■ ■
Tyachem 23 ■ ■ ■
Tyachem-Bloc 23 ■ ■ ■
Standardized pumps, seal-less Magnochem 23 ■ ■ ■
Magnochem-Bloc 23 ■ ■
Tyamagno 24 ■ ■
Tyamagno-Bloc 24 ■ ■
Etaseco / Etaseco-I 24 ■ ■ ■ ■ ■
Secochem Ex 24 ■ ■ ■
Secochem Ex K 24 ■ ■ ■
Process pumps RPH 25 ■ ■ ■
CTN 25 ■ ■
Rainwater harvesting systems Hya-Rain / Hya-Rain N 25 ■ ■
Hya-Rain-Duo 25 ■ ■
Ixo RWS 26 ■ ■
Domestic water supply systems with Multi Eco 26 ■ ■ ■ ■
automatic control unit / swimming pools Multi Eco-Pro 26 ■ ■ ■ ■
Multi Eco-Top 26 ■ ■ ■
Movitec VE 27 ■ ■ ■
Ixo 27 ■ ■ ■ ■
Filtra 27 ■
Pressure boosting units Hya-Solo E / D / DV 27 ■ ■ ■
Hya-Eco 28 ■ ■ ■
Hyamat K 28 ■ ■ ■ ■
Hyamat V 28 ■ ■ ■ ■
Hyamat VP 28 ■ ■ ■ ■
Hyamat IK, IV, IVP 28 ■
Drainage pumps / Ama-Drainer 301, 303, 324, 356 29 ■ ■ ■
waste water pumps Ama-Drainer 405, 435, 505 29 ■ ■ ■
Ama-Drainer 80, 100 29 ■ ■ ■
Ama-Porter F / S / ICS 29 ■ ■
Rotex 29 ■ ■ ■
MK / MKY 30 ■ ■
Lifting units / collecting tanks Ama-Drainer-Box 30 ■ ■
Ama-Sani 30 ■
mini-Compacta 30 ■ ■
Compacta 31 ■ ■ ■
Evamatic-Box 31 ■
Evamatic-Box ICS 31 ■
Ama-Porter CK Pumping Station 31 ■
Amarex N CK Pumping Station 31 ■
Submersible motor pumps Amarex N 32 ■ ■ ■ ■
Amarex KRT 32 ■ ■ ■ ■

A Automation possible

6
Building Services
Waste Water

Industry

Mining
Energy
Water
Type / Application Type Series Page A Segment

Submersible motor pumps Amarex KRT, dry-installed 32 ■ ■ ■


Submersible pumps in discharge tubes Amacan K 33 ■ ■ ■
Amacan P 33 ■ ■ ■
Amacan S 33 ■ ■ ■
Mixers / agitators / Amamix 33 ■ ■
tank cleaning units Amaprop 34 ■ ■
Amajet 34 ■ ■
Amaline 34 ■ ■
Pumps for solids-laden fluids / Sewatec / Sewabloc 34 ■ ■ ■
positive displacement pumps KWP / KWP-Bloc 35 ■ ■ ■ ■
Getec / Getecbloc 35 ■ ■
Self-priming pumps Etaprime L 35 ■ ■
Etaprime B / BN 35 ■ ■
Submersible borehole pumps S 100B / UPA 100 C 36 ■ ■ ■ ■
UPA 150 S 36 ■ ■ ■ ■ ■
UPA 200, 200 B, 250 C 36 ■ ■ ■ ■ ■
UPA 300, 350 36 ■ ■ ■ ■ ■
UPZ, BSX-BSF 36 ■ ■ ■
High-pressure pumps, fixed / Movitec V / LHS 37 ■ ■ ■ ■ ■
variable speed Movitec PumpDrive 37 ■ ■ ■ ■
Multitec 37 ■ ■ ■ ■ ■
HGM-RO 37 ■
Axially split pumps Omega 38 ■ ■ ■ ■ ■ ■
RDLO 38 ■ ■ ■ ■ ■ ■
Stainless steel pumps Vitachrom 38 ■ ■
for the food industry
Pumps for power station CHTA / CHTC / CHTD 39 ■
conventional islands HGB / HGC / HGD 39 ■ ■
HGM 39 ■ ■
YNK / KRHA 39 ■
RHD 39 ■
MBH 40 ■
LUV / LUVA / LUVB 40 ■
WKT / WKTA / WKTB 40 ■
SEZ / PHZ / PNZ 40 ■ ■
SNW / PNW 40 ■ ■
SPY 41 ■ ■ ■ ■
Pumps for power station RER 41 ■
nuclear islands RSR 42 ■
PSR 42 ■
RHM 42 ■
RVM 42 ■
RHR / RVR 42 ■
Slurry pumps FGD 43 ■ ■ ■
LSR 43 ■
LCV 43 ■
WBC 43 ■
LSA 43 ■ ■ ■
LCC 44 ■ ■ ■
HHD 44 ■
TBC 44 ■
MHD 44 ■
LHD 44 ■

Automation
Control systems hyatronic K / N 45 ■ ■ ■ ■
hyatronic S 45 ■ ■ ■ ■
hyatronic SP 45 ■ ■ ■ ■
hyatronic mb 45 ■ ■ ■ ■
Hyamaster ISB 45 ■ ■ ■ ■
Hyamaster SPS 46 ■ ■ ■ ■
hyatronic MSB / spc 46 ■ ■ ■ ■
Hya-Drive 46 ■ ■ ■
PumpDrive 46 ■ ■ ■
Monitoring and diagnostic systems Amacontrol 47 ■ ■ ■
PumpExpert 47 ■ ■ ■
Switchgears and control systems Controlmatic E 47 ■ ■
Cervomatic EDP 47 ■ ■
UPA Control 48 ■ ■
Single-pump control system 48 ■ ■ ■ ■
Dual-pump control system 48 ■ ■ ■ ■

A Automation possible

7
Etanorm PumpDrive / Etabloc PumpDrive
Pumps

Etamagno SY / SYI / Bloc SY


Etanorm / Etanorm R
Etaline Z PumpDrive

Etanorm GPV / CPV


Rio-Eco / Rio-Eco Z

Etanorm SYA / RSY


Etaline PumpDrive
Riovar / Riovar Z

Riotec / Riotec Z

Etachrom NC
Etachrom BC
Riotherm C
Rio / Rio Z

Euro-CPK
Riotherm

Trialine Z
Riotronic

Etaline Z

Etabloc
Fluids

Trialine
Etaline

CPK-H
CPK-D
HPK-L

CPKN

CPKO
Rio C

HPH
HPK

CPK
Activated sludge
Circulator pumps / hot water service pumps, fixed speed

Circulator pumps, variable speed

In-line pumps with fixed / variable speed drive

Standardized / close-coupled pumps, fixed / variable speed

Hot water pumps

Hot water / thermal oil pumps, standardized

Mag-drive thermal oil pumps

Standardized chemical pumps


Aggressive liquids ■ ■ ■ ■ ■
Brackish water ■ ■ ■ ■ ■ ■
Brine ■ ■ ■ ■ ■ ■
Cleaning agents ■ ■ ■ ■ ■ ■ ■ ■
Condensate
Cooling water ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Corrosive liquids
Destillate ■ ■ ■
Digested sludge
Dipping paints ■ ■
Drinking water ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Explosive liquids ■ ■ ■ ■ ■
Feed water ■ ■ ■
Fire-fighting water ■ ■ ■ ■ ■ ■ ■ ■ ■
Flammable liquids ■ ■ ■ ■ ■
Fuels ■ ■ ■
Gas-containing liquids ■
Harmful liquids ■ ■ ■ ■ ■
Highly aggressive liquids ■ ■ ■ ■ ■
Hot water ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Inorganic liquids ■ ■ ■ ■ ■
Lubricants ■ ■ ■ ■ ■
Oils ■ ■ ■ ■ ■ ■ ■ ■ ■
Organic liquids ■ ■ ■ ■ ■ ■ ■
Polymerizing liquids ■ ■
Raw sludge
River, lake and ground water ■ ■
Seawater ■ ■ ■ ■
Service water ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Sewage with faeces
Sewage without faeces ■ ■
Slurries
Slurries (ore, sand, gravel, ash)
Solvents ■ ■ ■
Thermal oil ■ ■ ■
Toxic liquids ■ ■ ■ ■
Valuable liquids ■ ■ ■ ■ ■ ■
Volatile liquids ■ ■ ■
Waste water
Wash water ■

8
Ama-Drainer 301, 303, 324, 356
Ama-Drainer 405, 435, 505
Hya-Rain / Hya-Rain N

Ama-Porter F / S / ICS
Ama-Drainer 80, 100
Hya-Solo E / D / DV
Etaseco / Etaseco-I

Hyamat IK, IV, IVP


Magnochem-Bloc

Tyamagno-Bloc

Secochem Ex K

Hya-Rain-Duo

Multi Eco-Top
Tyachem-Bloc

Multi Eco-Pro
Secochem Ex
Magnochem

Movitec VE

Hyamat VP
Tyamagno

MK / MKY
Hyamat K
Hyamat V
Multi Eco
Tyachem

Ixo RWS

Hya-Eco

Rotex
Filtra
CTN
RPH

Ixo
Activated sludge
Standardized pumps, seal-less

Process pumps

Rainwater harvesting systems

Pressure boosting units


Domestic water supply systems with automatic control unit / swimming pools

Drainage pumps / waste water pumps


■ ■ ■ ■ ■ ■ ■ ■ Aggressive liquids
Brackish water
■ ■ ■ ■ ■ Brine
■ ■ ■ ■ ■ ■ Cleaning agents
■ Condensate
■ ■ ■ ■ ■ ■ ■ ■ Cooling water
■ ■ ■ ■ ■ ■ ■ ■ Corrosive liquids
■ ■ ■ ■ ■ Destillate
Digested sludge
■ ■ ■ ■ ■ Dipping paints
■ ■ ■ ■ ■ Drinking water
■ ■ ■ ■ ■ Explosive liquids
Feed water
■ ■ ■ Fire-fighting water
■ ■ ■ ■ ■ ■ Flammable liquids
■ ■ ■ ■ ■ Fuels
Gas-containing liquids
■ ■ ■ ■ ■ ■ ■ ■ Harmful liquids
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Highly aggressive liquids
■ ■ ■ ■ Hot water
■ ■ ■ ■ ■ Inorganic liquids
■ Lubricants
■ ■ ■ ■ ■ ■ ■ Oils
■ ■ ■ ■ ■ ■ Organic liquids
■ Polymerizing liquids
Raw sludge
■ ■ ■ ■ ■ River, lake and ground water
■ Seawater
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Service water
Sewage with faeces
■ ■ ■ ■ ■ ■ ■ ■ ■ Sewage without faeces
Slurries
■ ■ Slurries (ore, sand, gravel, ash)
■ ■ ■ ■ ■ ■ Solvents
■ ■ ■ ■ ■ Thermal oil
■ ■ ■ ■ ■ ■ Toxic liquids
■ ■ ■ ■ ■ ■ Valuable liquids
■ ■ ■ ■ ■ ■ Volatile liquids
■ ■ ■ ■ ■ ■ Waste water
Wash water

9
Pumps

Ama-Porter CK Pumping Station


Amarex N CK Pumping Station

Amarex KRT, dry-installed

UPA 200, 200 B, 250 C


S 100 B / UPA 100 C
Sewatec / Sewabloc

Movitec PumpDrive
Getec / Getecbloc
Evamatic-Box ICS
Ama-Drainer-Box

KWP / KWP-Bloc

Etaprime B / BN

Movitec V / LHS
mini-Compacta

UPA 300, 350


UPZ, BSX-BSF
Evamatic-Box

Amarex KRT

Etaprime L

UPA 150 S
Amacan K
Amacan P
Compacta

Amarex N

Amacan S
Ama-Sani

Amaprop

HGM-RO
Amamix

Amaline

Multitec
Fluids

Amajet
Activated sludge ■ ■ ■ ■ ■
Lifting units / collecting tanks

Submersible motor pumps

Submersible pumps in discharge tubes

Mixers / agitators / tank cleaning units

Self-priming pumps
Pumps for solids-laden fluids / positive displacement pumps

Submersible borehole pumps

High-pressure pumps, fixed / variable speed


Aggressive liquids ■ ■ ■
Brackish water
Brine
Cleaning agents ■
Condensate ■
Cooling water ■ ■ ■ ■ ■ ■ ■ ■
Corrosive liquids
Destillate ■ ■ ■
Digested sludge ■ ■ ■ ■
Dipping paints
Drinking water ■ ■ ■ ■ ■ ■ ■ ■
Explosive liquids
Feed water ■
Fire-fighting water ■ ■
Flammable liquids
Fuels ■
Gas-containing liquids ■ ■ ■
Harmful liquids
Highly aggressive liquids
Hot water
Inorganic liquids
Lubricants ■
Oils
Organic liquids
Polymerizing liquids
Raw sludge ■ ■ ■ ■
River, lake and ground water ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Seawater ■ ■ ■ ■ ■ ■ ■ ■ ■
Service water ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Sewage with faeces ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Sewage without faeces ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Slurries ■
Slurries (ore, sand, gravel, ash) ■
Solvents ■
Thermal oil
Toxic liquids
Valuable liquids
Volatile liquids
Wash water ■ ■
Waste water ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

10
CHTA / CHTC / CHTD

WKT / WKTA / WKTB


LUV / LUVA / LUVB
HGB / HGC / HGD

SEZ / PHZ / PNZ


YNK / KRHA

SNW / PNW

RHR / RVR
Vitachrom
Omega
RDLO

HGM

MHD
MBH

RHM

WBC
RVM

HHD
RHD

FGD

LHD
RER

TBC
RSR

LCV

LCC
SPY

PSR

LSA
LSR
Activated sludge
Axially split pumps

Stainless steel pumps for the food industry

Pumps for power station conventional islands

Pumps for power station nuclear islands

Slurry pumps
■ Aggressive liquids
■ ■ Brackish water
Brine
Cleaning agents
■ ■ ■ ■ ■ Condensate
■ ■ ■ ■ ■ ■ ■ ■ ■ Cooling water
■ Corrosive liquids
Destillate
Digested sludge
Dipping paints
■ ■ Drinking water
Explosive liquids
■ ■ ■ ■ ■ ■ ■ Feed water
■ ■ Fire-fighting water
Flammable liquids
Fuels
Gas-containing liquids
Harmful liquids
Highly aggressive liquids
■ ■ ■ ■ ■ ■ ■ ■ ■ Hot water
Inorganic liquids
Lubricants
■ Oils
Organic liquids
Polymerizing liquids
Raw sludge
■ ■ ■ ■ ■ River, lake and ground water
■ ■ ■ ■ Seawater
■ ■ ■ ■ ■ Service water
■ Sewage with faeces
■ Sewage without faeces
Slurries
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Slurries (ore, sand, gravel, ash)
Solvents
Thermal oil
Toxic liquids
Valuable liquids
Volatile liquids
Wash water
Waste water

11
Etanorm PumpDrive / Etabloc PumpDrive
Pumps

Etamagno SY / SYI / Bloc SY


Etanorm / Etanorm R
Etaline Z PumpDrive

Etanorm GPV / CPV


Rio-Eco / Rio-Eco Z

Etanorm SYA / RSY


Etaline PumpDrive
Riovar / Riovar Z

Riotec / Riotec Z

Etachrom NC
Etachrom BC
Riotherm C
Rio / Rio Z

Euro-CPK
Riotherm

Trialine Z
Riotronic

Etaline Z

Etabloc
Applications

Trialine
Etaline

CPK-H
CPK-D
HPK-L

CPKN

CPKO
Rio C

HPH
HPK

CPK
Air-conditioning systems ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Aquaculture
Circulator pumps / hot water service pumps, fixed speed

Circulator pumps, variable speed

In-line pumps with fixed / variable speed drive

Standardized / close-coupled pumps, fixed / variable speed

Hot water pumps

Hot water / thermal oil pumps, standardized

Mag-drive thermal oil pumps

Standardized chemical pumps


Boiler circulation ■ ■ ■
Boiler feed applications ■ ■
Chemical industry ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Cleaning of stormwater tanks / storage sewers
Condensate transport ■ ■ ■ ■ ■ ■ ■ ■
Cooling circuits ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Descaling units
Dewatering ■ ■ ■ ■ ■ ■
District heating ■ ■ ■ ■ ■ ■ ■ ■
Disposal
Dock facilities
Domestic water supply
Drainage
Drainage of pits, shafts, etc.
Fire-fighting systems ■ ■ ■ ■
Flue gas desulphurization
Food and beverages industry ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Fountains
Heat recovery systems ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Heavy oil and coal upgrading ■ ■ ■
Homogenization
Hot water heating systems ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Hydraulic solids transport
Industrial recirculation systems ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Irrigation ■ ■ ■ ■ ■ ■
Keeping in suspension
Lowering ground water levels
Maintaining ground water levels
Mining
Mixing ■
Nuclear power stations ■ ■
Paint shops ■ ■
Paper and cellulose industry ■ ■ ■ ■
Petrochemical industry ■ ■ ■ ■ ■
Pipelines and tank farms ■ ■ ■
Pressure boosting
Process engineering ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Rainwater harvesting
Recirculation
Refineries ■ ■ ■

Reverse osmosis ■ ■

Seawater desalination ■ ■

Sewage treatment plants ■ ■ ■ ■ ■ ■

Shipbuilding
Sludge disposal
Sludge processing
Snow guns
Spray irrigation ■ ■ ■ ■ ■

Sugar industry ■ ■ ■ ■

Swimming pools ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Thickening
Washing plants
Water extraction ■ ■

Water supply ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Water treatment systems ■ ■ ■

12
Ama-Drainer 301, 303, 324, 356
Ama-Drainer 405, 435, 505
Hya-Rain / Hya-Rain N

Ama-Porter F / S / ICS
Ama-Drainer 80, 100
Hya-Solo E / D / DV
Etaseco / Etaseco-I

Hyamat IK, IV, IVP


Magnochem-Bloc

Tyamagno-Bloc

Secochem Ex K

Hya-Rain-Duo

Multi Eco-Top
Tyachem-Bloc

Multi Eco-Pro
Secochem Ex
Magnochem

Movitec VE

Hyamat VP
Tyamagno

MK / MKY
Hyamat K
Hyamat V
Multi Eco
Tyachem

Ixo RWS

Hya-Eco

Rotex
Filtra
CTN
RPH

Ixo
■ ■ ■ ■ ■ Air-conditioning systems
Aquaculture
Standardized pumps, seal-less

Process pumps

Rainwater harvesting systems

Pressure boosting units


Domestic water supply systems with automatic control unit / swimming pools

Drainage pumps / waste water pumps


■ Boiler circulation
Boiler feed applications
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Chemical industry
Cleaning of stormwater tanks / storage sewers
■ ■ ■ ■ ■ ■ ■ Condensate transport
■ ■ ■ ■ ■ ■ Cooling circuits
Descaling units
■ ■ ■ ■ ■ ■ Dewatering
■ ■ ■ ■ ■ District heating
■ ■ ■ ■ ■ ■ Disposal
Dock facilities
■ ■ ■ ■ ■ ■ Domestic water supply
■ ■ ■ ■ ■ ■ Drainage
■ ■ ■ Drainage of pits, shafts, etc.
■ ■ ■ Fire-fighting systems
■ ■ ■ ■ Flue gas desulphurization
■ ■ ■ ■ ■ ■ Food and beverages industry
■ Fountains
Heat recovery systems
■ Heavy oil and coal upgrading
Homogenization
■ ■ ■ ■ ■ Hot water heating systems
■ ■ Hydraulic solids transport
■ ■ ■ ■ ■ ■ Industrial recirculation systems
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Irrigation
Keeping in suspension
Lowering ground water levels
Maintaining ground water levels
Mining
Mixing
■ ■ ■ ■ ■ Nuclear power stations
■ Paint shops
■ ■ Paper and cellulose industry
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Petrochemical industry
■ ■ ■ ■ ■ ■ Pipelines and tank farms
■ ■ ■ ■ ■ ■ ■ Pressure boosting
■ ■ ■ ■ ■ ■ ■ ■ Process engineering
■ ■ ■ ■ ■ ■ ■ ■ Rainwater harvesting
Recirculation
■ ■ ■ ■ ■ Refineries
■ Reverse osmosis
■ Seawater desalination
Sewage treatment plants
Shipbuilding
Sludge disposal
Sludge processing
Snow guns
■ ■ ■ ■ ■ ■ ■ ■ ■ Spray irrigation
■ ■ ■ ■ ■ ■ ■ ■ Sugar industry
■ Swimming pools
Thickening
■ ■ ■ ■ ■ ■ ■ Washing plants
■ ■ ■ ■ ■ ■ ■ Water extraction
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Water supply
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Water treatment systems

13
Pumps

Ama-Porter CK Pumping Station


Amarex N CK Pumping Station

Amarex KRT, dry-installed

UPA 200, 200 B, 250 C


S 100 B / UPA 100 C
Sewatec / Sewabloc

Movitec PumpDrive
Getec / Getecbloc
Evamatic-Box ICS
Ama-Drainer-Box

KWP / KWP-Bloc

Etaprime B / BN

Movitec V / LHS
mini-Compacta

UPA 300, 350


UPZ, BSX-BSF
Evamatic-Box

Amarex KRT

Etaprime L

UPA 150 S
Amacan K
Amacan P
Compacta

Amarex N

Amacan S
Ama-Sani

Amaprop

HGM-RO
Amamix

Amaline

Multitec
Applications

Amajet
Air-conditioning systems ■
Aquaculture ■ ■
Lifting units / collecting tanks

Submersible motor pumps

Submersible pumps in discharge tubes

Mixers / agitators / tank cleaning units

Pumps for solids-laden fluids / positive displacement pumps

Self-priming pumps

Submersible borehole pumps

High-pressure pumps, fixed / variable speed


Boiler circulation
Boiler feed systems ■ ■ ■
Chemical industry ■ ■ ■
Cleaning of stormwater tanks / storage sewers ■ ■
Condensate transport ■
Cooling circuits ■ ■
Descaling units ■ ■ ■
Dewatering ■ ■ ■ ■ ■ ■ ■
Disposal ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
District heating
Dock facilities
Domestic water supply ■
Drainage ■ ■ ■
Drainage of pits, shafts, etc.
Fire-fighting systems ■ ■ ■ ■ ■ ■ ■
Flue gas desulphurization ■ ■
Food and beverages industry ■ ■ ■ ■ ■ ■ ■ ■ ■
Fountains ■ ■
Heavy oil and coal upgrading
Heat recovery systems
Homogenization ■
Hot water heating systems ■
Hydraulic solids transport ■
Industrial recirculation systems ■ ■ ■
Irrigation ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Keeping in suspension ■
Lowering ground water levels ■ ■ ■ ■ ■
Maintaining ground water levels ■ ■ ■ ■ ■ ■
Mining ■ ■ ■ ■
Mixing ■
Nuclear power stations
Paint shops ■ ■
Paper and cellulose industry ■ ■ ■ ■ ■ ■ ■ ■
Petrochemical industry ■ ■
Pipelines and tank farms
Pressure boosting ■ ■ ■ ■ ■
Process engineering
Rainwater harvesting ■ ■
Recirculation ■
Refineries
Reverse osmosis ■

Sewage treatment plants ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Seawater desalination ■ ■ ■ ■ ■

Shipbuilding
Sludge disposal ■

Sludge processing ■

Snow guns ■

Spray irrigation ■ ■ ■ ■ ■ ■

Sugar industry ■

Swimming pools
Thickening ■

Washing plants ■ ■ ■

Water extraction ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Water supply ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Water treatment systems ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

14
CHTA / CHTC / CHTD

WKT / WKTA / WKTB


LUV / LUVA / LUVB
HGB / HGC / HGD

SEZ / PHZ / PNZ


YNK / KRHA

SNW / PNW

RHR / RVR
Vitachrom
Omega
RDLO

HGM

MHD
MBH

RHM

WBC
RVM

HHD
RHD

FGD

LHD
RER

TBC
RSR

LCV

LCC
SPY

PSR

LSA
LSR
Air-conditioning systems
Aquaculture
Axially split pumps

Stainless steel pumps for the food industry

Pumps for power station conventional islands

Pumps for power station nuclear islands

Slurry pumps
■ Boiler circulation
■ ■ ■ ■ ■ ■ ■ Boiler feed systems
■ ■ ■ Chemical industry
Cleaning of stormwater tanks / storage sewers
■ ■ ■ ■ ■ Condensate transport
■ ■ ■ ■ ■ ■ ■ ■ Cooling circuits
■ ■ Descaling units
■ ■ ■ ■ Dewatering
Disposal
■ ■ District heating
■ ■ ■ Dock facilities
Domestic water supply
■ Drainage
Drainage of pits, shafts, etc.
■ ■ Fire-fighting systems
■ Flue gas desulphurization
■ Food and beverages industry
Fountains
Heavy oil and coal upgrading
Heat recovery systems
Homogenization
Hot water heating systems
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Hydraulic solids transport
Industrial recirculation systems
■ ■ ■ ■ ■ Irrigation
Keeping in suspension
Lowering ground water levels
Maintaining ground water levels
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Mining
Mixing
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Nuclear power stations
Paint shops
Paper and cellulose industry
■ ■ ■ ■ Petrochemical industry
Pipelines and tank farms
Pressure boosting
Process engineering
Rainwater harvesting
Recirculation
■ ■ Refineries
Reverse osmosis
■ ■ Sewage treatment plants
■ ■ ■ Seawater desalination
■ ■ Shipbuilding
Sludge disposal
Sludge processing
■ ■ Snow guns
Spray irrigation
Sugar industry
Swimming pools
Thickening
Washing plants
■ ■ ■ ■ ■ Water extraction
■ ■ ■ ■ ■ Water supply
■ ■ Water treatment systems

15
Circulator pumps / hot water service pumps,
fixed speed

Rio / Rio Z Circulator pump

Rp / DN 1-11/4 32 - 100 Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with
Q m3/h up to 90 three speed levels; in twin pump design (Rio Z) for standby operation with
Hm up to 12 integrated swing check valve or, on option, peak load operation (parallel operation).
p bar up to 10 Applications: Hot water heating systems, heat recovery systems and cooling cir-
T °C -20 to +130 cuits in air-conditioning systems.
n min -1 up to 2,800

A Switchgears Reference no. 1115.51

Rio C Circulator pump with manual speed control

Rp 1 -11/4 Design: Maintenance-free, glandless wet rotor pump, screw-ended, with three
Q m3/h up to 4 speed levels.
Hm up to 5.6 Applications: Hot water heating systems, heat recovery systems and cooling cir-
p bar up to 10 cuits in air-conditioning systems.
T °C -10 to +110
n min -1 up to 2,800

Reference no. 1120.5

Riovar / Riovar Z Circulator pump with manual speed control

Rp / DN 1-11/4 32 - 100 Design: Maintenance-free, glandless wet rotor pump (Riovar), flanged or screw-
Q m3/h up to 80 ended, with four speed levels; in twin pump design (Riovar Z) for standby operation
Hm up to 16 with integrated swing check valve or, on option, peak load operation (parallel
p bar up to 10 operation).
T °C +20 to +130 Applications: Hot water heating systems and heat recovery systems.
n min -1 up to 2,800

A Switchgears Reference no. 1111.5

Riotherm C Hot water service pump

Rp / DN 1
/2 -11/4 40 - 50 Design: Maintenance-free, glandless wet rotor pump, screw-ended, with three
Q m3/h up to 28 speed levels.
Hm up to 7.5 Applications: Hot water supply, heat transfer / recovery systems and cooling cir-
p bar up to 10 cuits in air-conditioning systems.
T °C -10 to +110
n min -1 up to 2,800

Reference no. 1109.5

Riotherm Hot water service pump

Rp 1-11/4 Design: Screw-ended dry rotor pump with mechanical seal and fixed speed.
Q m3/h up to 10 Applications: Hot water supply systems, swimming pools, cooling circuits and
Hm up to 6 industrial plants.
p bar up to 10
T °C -2 to +110
n min -1 up to 2,800

Reference no. 1118.5

16 A Automation possible
Circulator pumps, variable speed

Rio-Eco / Rio-Eco Z Circulator pump with continuously variable differential pressure control

Rp / DN 11/4 32 - 65 Design: Maintenance-free wet rotor pump with integrated frequency inverter for
Q m3/h up to 44 continuously variable differential pressure control and IR interface for remote con-
Hm up to 13 trol.
p bar up to 10 Applications: Hot water heating systems, heat recovery systems and cooling cir-
T °C -10 to +110 cuits in air-conditioning systems.
n min -1 up to 4,800

Reference no. 1137.5

Riotronic Circulator pump with continuously variable differential pressure control

Rp 1-11/4 Design: Maintenance-free, glandless wet rotor pump, screw-ended, with integrated
Q m3/h up to 4 electronics for continuously variable differential pressure control, operation / fault
Hm up to 6 LEDs and volt-free contact on Riotronic SSM; pump casing with heat insulation.
p bar up to 10 Applications: Hot water heating systems and heat recovery systems.
T °C +20 to +110
n min -1 up to 2,600

Reference no. 1112.5

Riotec / Riotec Z Circulator pump with continuously variable differential pressure control

Rp / DN 1-11/4 32 - 100 Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with
Q m3/h up to 90 integrated frequency inverter for continuously variable differential pressure control
Hm up to 10 and IR interface for remote control; twin pump design (Riotec Z) for standby opera-
p bar up to 10 tion with integrated swing check valve or, on option, peak load operation (parallel
T °C +20 to +110 operation).
n min -1 up to 2,850 Applications: Hot water heating systems and heat recovery systems.

Reference no. 1115.52

In-line pumps with fixed / variable speed drive

Trialine In-line pump

DN 32 - 80 Design: Close-coupled in-line pump with common pump / motor shaft.


Q m3/h up to 140 Applications: Hot water heating systems, cooling circuits, air-conditioning and
Hm up to 45 water supply systems.
p bar up to 10
T °C -15 to +120
n min -1 up to 2,900

A hyatronic • Switchgears Reference no. 1144.51

A Automation possible 17
In-line pumps with fixed / variable speed drive

Etaline In-line pump

DN 32 - 200 Design: Close-coupled, in-line circulator pump with volute casing and standardized
Q m3/h up to 550 motor.
Hm up to 90 Applications: Hot water heating systems, cooling circuits, air-conditioning, water
p bar up to 16 and service water supply systems, industrial recirculation systems.
T °C -30 to +140
n min -1 up to 2,900

A Hyamaster • hyatronic • Switchgears Reference no. 1146.51

Trialine Z In-line twin pump

DN 32 - 80 Design: Close-coupled in-line pump with common pump / motor shaft; in twin
Q m3/h up to 120 pump design for standby operation with integrated change-over flap or, on option,
Hm up to 30 peak load operation (parallel operation).
p bar up to 10 Applications: Hot water heating systems, cooling circuits, air-conditioning and
T °C -15 to +120 water supply systems.
n min -1 up to 2,900

A hyatronic • Switchgears Reference no. 1144.52

Etaline Z In-line twin pump

DN 32 - 200 Design: Close-coupled, in-line twin circulator pump, pump shaft and motor shaft
Q m3/h up to 1120 are rigidly coupled.
Hm up to 38 Applications: Hot water heating systems, cooling circuits, air-conditioning systems,
p bar up to 16 water and service water supply systems, industrial recirculation systems.
T °C -30 to +140
n min -1 up to 1,450

A Hyamaster • hyatronic • Switchgears Reference no. 1148.5

Etaline PumpDrive / Etaline Z PumpDrive In-line pump with integrated frequency inverter

DN 32 - 150 Design: Close-coupled in-line circulator pump, also available in twin pump design,
Q m3/h up to 420 motor with integrated frequency inverter; pump shaft and motor shaft are rigidly
Hm up to 100 coupled.
p bar up to 16 Applications: Hot water heating systems, cooling circuits, air-conditioning systems,
T °C -10 to +110 water and service water supply systems, industrial recirculation systems.
n min -1 up to 4,200

A PumpDrive Reference nos. 1149.51/1154.5 also available in 60 Hz

18 A Automation possible
Standardized / close-coupled pumps,
fixed / variable speed

Etanorm / Etanorm R Standardized cast iron pump

DN 32 - 300 Design: Horizontal, long-coupled, single-stage volute casing pump (pump size >
Q m3/h up to 1900 125 with two stages) in back pull-out design, with replaceable shaft sleeves / shaft
Hm up to 102 protecting sleeves and casing wear rings. Design to ATEX.
p bar up to 16 Applications: Spray irrigation, irrigation, drainage, district heating, water supply
T °C up to +140 systems, heating and air-conditioning systems, condensate transport, swimming
n min -1 up to 2,900 pools, handling of hot water, cooling water, fire-fighting water, oil, brine, drinking
water, brackish water, service water, etc.

A PumpExpert • Hya-Drive/PumpDrive • Hyamaster • hyatronic Reference no. 1211.5 also available in 60 Hz

Etabloc Close-coupled cast iron pump

DN 25 - 150 Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, with
Q m3/h up to 650 replaceable shaft sleeve and casing wear rings. Design to ATEX.
Hm up to 101 Applications: Spray irrigation, irrigation, drainage and water supply systems, heat-
p bar up to 16 ing and air-conditioning systems, condensate transport, swimming pools, handling
T °C up to +140 of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking water,
n min -1 up to 2,900 cleaning agents, brackish water, service water, etc.

A Hya-Drive/PumpDrive • Hyamaster • hyatronic Reference no. 1167.5 also available in 60 Hz

Etanorm PumpDrive / Etabloc PumpDrive Standardized close-coupled pump with integrated frequeny inverter

DN 32 - 150 Design: Single-stage, close-coupled volute casing pump, motor with integrated fre-
Q m3/h up to 602 quency inverter, with replaceable shaft protecting sleeves and impeller wear rings.
Hm up to 102 Applications: Spray irrigation, irrigation, drainage and water supply systems, heat-
p bar up to 16 ing and air-conditioning systems, condensate transport, swimming pools, handling
T °C up to +110 of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking water,
n min -1 up to 4,400 cleaning agents, brackish water, service water, etc.

A PumpExpert (only for Etanorm PumpDrive) Reference no. 1216.5 also available in 60 Hz

Etachrom BC Close-coupled chrome steel pump

DN 25 - 80 Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings


Q m3/h up to 250 and main dimensions to EN 733, with replaceable casing wear rings. Design to
Hm up to 108 ATEX.
p bar up to 12 Applications: Spray irrigation, irrigation, drainage and water supply systems, heat-
T °C up to +110 ing and air-conditioning systems, fire-fighting systems, swimming pools, handling of
n min -1 up to 2,900 condensate, hot water, cooling water, fire-fighting water, oil, drinking water, clean-
ing agents, service water.

A Hya-Drive • Hyamaster • hyatronic Reference no. 1213.5 also available in 60 Hz

Etachrom NC Standardized chrome steel pump

DN 25 - 80 Design: Horizontal, single-stage annular casing pump, with ratings and main
Q m3/h up to 260 dimensions to EN 733, with replaceable casing wear rings. Design to ATEX.
Hm up to 106 Applications: Water supply, spray irrigation, irrigation and drainage systems, heat-
p bar up to 12 ing and air-conditioning systems, handling of drinking water, service water, hot
T °C up to +110 water, cooling water, swimming pool water, fire-fighting water, condensate, oil and
n min -1 up to 2,900 cleaning agents.

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference no. 1212.5 also available in 60 Hz

A Automation possible 19
Standardized / close-coupled pumps,
fixed / variable speed

Etanorm GPV / CPV Vertical low-pressure pump

DN 32 - 150 Design: Single-stage volute casing pump, ratings to EN 733, for vertical installation
Q m3/h up to 660 in closed tanks under atmospheric pressure.
Hm up to 100 Applications: Handling of neutral degreasing and phosphatizing solutions, wash
p bar up to 16 water with degreasing agents, dipping paints, etc.
T °C up to +70
n min -1 up to 2,900

A Hya-Drive • Hyamaster • hyatronic Reference no. 1214.0

Hot water pumps

HPK-L Hot water recirculation pump without external cooling

DN 25 - 150 Design: Horizontal, radially split volute casing pump in back pull-out design to EN
Q m3/h up to 460 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Hm up to 95 Equipped with heat barrier, seal chamber air-cooled by integrated fan impeller, no
p bar up to 40 external cooling.
T °C up to +240 Applications: Handling of hot water in piping or tank systems, particularly in
n min -1 up to 2,900 medium-sized and large heating systems, forced circulation boilers, district heating
Higher values available upon request systems, etc.

A Hya-Drive • Hyamaster • hyatronic Reference no. 1136.5 also available in 60 Hz

HPK Hot water recirculation pump

DN 25 - 400 Design: Horizontal, radially split volute casing pump in back pull-out design to EN
Q m3/h up to 4,150 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. TÜV
Hm up to 185 certification to TRD on option.
p bar up to 40 Applications: Handling of hot water and thermal oil in piping or tank systems, par-
T °C up to +240 ticularly in medium-sized and large heating systems, forced circulation boilers, dis-
n min -1 up to 2,900 trict heating systems, etc.
Higher values available upon request

A Hya-Drive • Hyamaster • hyatronic Reference no. 1121.51 also available in 60 Hz

HPH Hot water recirculation pump

DN 40 - 300 Design: Horizontal, radially split volute casing pump in back pull-out design,
Q m3/h up to 1,800 single-stage, single-entry, with centreline pump feet and radial impeller. TÜV
Hm up to 225 certification to TRD on option.
p bar up to 110 Applications: Handling of hot water in high-pressure hot water generation plants
T °C up to +320 and for use as boiler feed and recirculation pump.
n min -1 up to 2,900
Higher values available upon request

A Hya-Drive • Hyamaster • hyatronic Reference no. 1122.5 also available in 60 Hz

20 A Automation possible
Hot water / thermal oil pumps

Etanorm SYA / RSY Hot water / thermal oil pump

DN 32 - 300 Design: Horizontal, long-coupled volute casing pump in back pull-out design with
Q m3/h up to 1,900 ratings and main dimensions to EN 733, single-stage, with replaceable casing wear
Hm up to 102 rings. Design to ATEX.
p bar up to 16 Applications: Heat transfer systems (DIN 4754, VDI 3033) or hot water recircula-
T °C up to +350 tion.
n min -1 up to 2,900

A PumpExpert • Hyamaster • hyatronic Reference no. 1220.5 also available in 60 Hz

Mag-drive thermal oil pumps

Etamagno SY / SYI / Bloc SY Thermal oil pump

DN 32 - 150 Design: Horizontal, single-stage, seal-less volute casing pump with magnetic drive,
Q m3/h up to 660 ratings and main dimensions to EN 733, with replaceable casing wear rings.
Hm up to 102 Applications: Handling of thermal oil in heat transfer systems to DIN 4754.
p bar up to 16
T °C up to +350
n min -1 up to 2,900

A PumpExpert • Hyamaster • hyatronic Reference no. 1218.5 also available in 60 Hz

Standardized chemical pumps

Euro-CPK Standardized chemical pump, stainless steel, with conical cover

DN 25 - 150 Design: Horizontal, radially split volute casing pump in back pull-out design to EN
Q m3/h up to 450 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Hm up to 155 Applications: Handling of aggressive, organic and inorganic liquids in chemical
p bar up to 16 and petrochemical processes, in the paper and cellulose industry, food and luxury
T °C up to +140 foods industry, sugar industry, refinery off-sites, absorption equipment in environ-
n min -1 up to 2,900 mental engineering systems, power stations, etc.
Higher values available upon request

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference no. 2717.5 also available in 60 Hz

A Automation possible 21
Standardized chemical pumps

CPK Standardized chemical pump

DN 25 - 400 Design: Horizontal, radially split volute casing pump in back pull-out design to EN
Q m3/h up to 4,150 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Hm up to 185 Applications: Handling of aggressive, organic and inorganic liquids in chemical
p bar up to 25 and petrochemical processes, in the paper and cellulose industry, food and luxury
T °C up to +400 foods industry, sugar industry, refinery off-sites, absorption equipment in environ-
n min -1 up to 2,900 mental engineering systems, power stations, seawater desalination plants, etc.
Higher values available upon request

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference no. 2721.5 also available in 60 Hz

CPKN Standardized chemical pump with reinforced bearing bracket

DN 25 - 250 Design: Horizontal, radially split volute casing pump in back pull-out design to EN
Q m3/h up to 1,000 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller, as CPK
Hm up to 150 variant with shaft reinforced in the shaft seal chamber, reinforced bearing assembly,
p bar up to 25 with “wet” shaft variant and / or conical seal chamber.
T °C up to +400 Applications: Handling of aggressive liquids in the chemical and petrochemical
n min -1 up to 2,900 industry.
Higher values available upon request

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference no. 2730.5 also available in 60 Hz

CPK-H Standardized chemical pump, heatable

DN 25 - 300 Design: Heatable, horizontal, radially split volute casing pump in back pull-out
Q m3/h up to 1,600 design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial
Hm up to 150 impeller and heating chamber on suction and discharge sides.
p bar up to 20 Applications: Handling of liquids which must not cool off in the system in the
T °C up to +300 chemical and petrochemical industry.
n min -1 up to 2,900
Higher values available upon request

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference no. 2725.5 also available in 60 Hz

CPK-D Standardized chemical pump with hydrodynamic shaft seal

DN 32 - 250 Design: Horizontal, radially split volute casing pump in back pull-out design to ISO
Q m3/h up to 1,100 2858, single-stage, single-entry, with radial impeller and zero-leakage hydrodynamic
Hm up to 128 shaft seal.
p bar up to 25 Applications: Handling of liquids in the chemical and petrochemical industry, in
T °C up to +150 refineries and paint shops.
n min -1 up to 2,900
Higher values available upon request

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference no. 2726.1/6 also available in 60 Hz

CPKO Standardized chemical pump with open impeller

DN 25 - 100 Design: Horizontal, radially split volute casing pump in back pull-out design to EN
Q m3/h up to 305 22858 / ISO 2858 / ISO 5199, single-stage, single-entry, with open impeller; in
Hm up to 154 proven CPK standardized modular design.
p bar up to 16 Applications: Handling of aggressive and polymerizing liquids, liquids liable to clot
T °C up to +300 and gas-containing liquids in the chemical and petrochemical industry.
n min -1 up to 2,900
Higher values available upon request

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference no. 2737.1/3 also available in 60 Hz

22 A Automation possible
Standardized chemical pumps

Tyachem Standardized chemical pump, plastic-lined

DN 32 - 100 Design: Horizontal, radially split centrifugal pump in back pull-out design to EN
Q m3/h up to 300 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller; shaft
Hm up to 95 sealed by mechanical seal, with replaceable plastic casing liner as an alternative to
p bar up to 16 high-grade metal alloys. Design to ATEX.
T °C up to +150 Applications: Handling of highly aggressive, corrosive and abrasive liquids in
n min -1 up to 2,900 process engineering, in the chemical and general industry.

A Hya-Drive • Hyamaster • hyatronic Reference no. 2791.5 also available in 60 Hz

Tyachem-Bloc Standardized chemical pump, close-coupled, plastic-lined

DN 25 - 50 Design: Horizontal, radially split centrifugal pump, close-coupled, single-stage,


Q m3/h up to 85 single-entry, with stub shaft and radial impeller; shaft sealed by mechanical seal,
Hm up to 58 with replaceable plastic casing liner as an alternative to high-grade metal alloys.
p bar up to 16 Design to ATEX.
T °C up to +150 Applications: Handling of highly aggressive, corrosive and abrasive liquids in
n min -1 up to 2,900 process engineering, in the chemical and general industry.

A Hya-Drive • Hyamaster • hyatronic Reference no. 2793.5 also available in 60 Hz

Standardized pumps, seal-less

Magnochem Standardized chemical pump

DN 25 - 250 Design: Horizontal, radially split, mag-drive volute casing pump in back pull-out
Q m3/h up to 1,250 design to ISO 2858 / EN 22 858 / ISO 5199, single-stage, single-entry, with radial
Hm up to 153 impeller, seal-less. Design to ATEX.
p bar up to 25 Applications: Handling of aggressive, toxic, explosive, valuable, flammable, mal-
T °C up to +300 odorous or harmful liquids in the chemical, petrochemical and general industry.
n min -1 up to 2,900

A PumpExpert • Hyamaster • hyatronic Reference no. 2739.5 also available in 60 Hz

Magnochem - Bloc Close-coupled chemical pump

DN 25 - 125 Design: Close-coupled, mag-drive volute casing pump to ISO 2858 / EN 22 858 /
Q m3/h up to 240 ISO 5199, single-stage, single-entry, with radial impeller, seal-less. Design to ATEX.
Hm up to 153 Applications: Handling of aggressive, toxic, explosive, valuable, flammable, mal-
p bar up to 25 odorous or harmful liquids in the chemical, petrochemical and general industry.
T °C up to +250
n min -1 up to 2,900

A PumpExpert • Hyamaster • hyatronic Reference no. 2749.5 also available in 60 Hz

A Automation possible 23
Standardized pumps, seal-less

Tyamagno Standardized chemical pump, plastic-lined

DN 32 - 80 Design: Horizontal, radially split, seal-less, mag-drive centrifugal pump in back


Q m3/h up to 230 pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with
Hm up to 95 radial impeller, replaceable plastic casing liner as an alternative to high-grade metal
p bar up to 16 alloys. Design to ATEX.
T °C up to +150 Applications: Handling of highly aggressive, corrosive and harmful liquids in
n min -1 up to 2,900 process engineering, in the chemical, petrochemical and general industry.

A Hya-Drive • Hyamaster • hyatronic Reference no. 2795.5 also available in 60 Hz

Tyamagno-Bloc Close-coupled chemical pump, plastic-lined

DN 32 - 50 Design: Close-coupled, horizontal, radially split, seal-less, mag-drive centrifugal


Q m3/h up to 85 pump to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial
Hm up to 58 impeller and replaceable plastic casing liner as an alternative to high-grade metal
p bar up to 16 alloys. Design to ATEX.
T °C up to +150 Applications: Handling of highly aggressive, corrosive and harmful liquids in
n min -1 up to 2,900 process engineering, in the chemical, petrochemical and general industry.

A Hya-Drive • Hyamaster • hyatronic Reference no. 2797.5 also available in 60 Hz

Etaseco / Etaseco-I Water motor pumps with canned motor

DN 32 - 100 Design: Horizontal / vertical, seal-less volute casing pump in back pull-out design
Q m3/h up to 250 with fully enclosed canned motor, low noise emission, with radial impeller, single-
Hm up to 100 stage, single-entry, pump casing connecting dimensions to EN 733.
p bar up to 16 Applications: Handling of aggressive, flammable, toxic, volatile, or valuable liquids
T °C up to +140 in the chemical and petrochemical industry, in environmental engineering and the
n min -1 up to 2,900 general industry.

A PumpExpert • Hyamaster • hyatronic Reference no. 2935.5 also available in 60 Hz

Secochem Ex Standardized chemical pump with canned motor and explosion protection

DN 25 - 100 Design: Horizontal, seal-less volute casing pump in back pull-out design with fully
Q m3/h up to 300 enclosed canned motor, low noise emission, with radial impeller, single-stage,
Hm up to 150 single-entry, casing connecting dimensions to EN 22 858 / ISO 2858, with explosion
p bar up to 25 protection. Design to ATEX.
T °C up to +130 Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valu-
n min -1 up to 2,900 able liquids in the chemical and petrochemical industry, in environmental engineer-
ing and the general industry.

A PumpExpert • Hyamaster • hyatronic Reference no. 2939.5 also available in 60 Hz

Secochem Ex K Standardized chemical pump with canned motor and explosion protection

DN 25 - 100 Design: Horizontal, seal-less volute casing pump in back pull-out design with fully
Q m3/h up to 300 enclosed canned motor, low noise emission, with radial impeller, single-stage,
Hm up to 150 single-entry, pump casing connecting dimensions to EN 22 858 / ISO 2858, with
p bar up to 25 explosion protection and external cooler. Design to ATEX.
T °C up to +400 Applications: Handling of aggressive, flammable, explosive, toxic, volatile or valu-
n 1/min -1 up to 2,900 able liquids in the chemical and petrochemical industry, in environmental engineer-
ing and the general industry.

A PumpExpert • Hyamaster • hyatronic Reference no. 2939.11 also available in 60 Hz

24 A Automation possible
Process pumps

RPH Process pump

DN 25 - 400 Design: Horizontal, radially split volute casing pump in back pull-out design to API
Q m3/h up to 4,150 610, 9th edition, or ISO 13709 (heavy duty), with radial impeller, single-stage,
Hm up to 270 single-entry, centreline pump feet; with inducer, if required.
p bar up to 51 Applications: Refineries, petrochemical and chemical industry, power stations and
T °C up to +400 seawater desalination systems.
n min -1 up to 2,900
Higher values available upon request

A PumpExpert • Hyamaster • hyatronic Reference nos. 1312.5/1316.51 also available in 60 Hz

CTN Chemical vertical shaft submersible pump

DN 25 - 250 Design: Radially split, vertical shaft submersible pump with double volute for wet
Q m3/h up to 800 and dry installation, single- or double stage, single-entry, with radial impeller; heat-
Hm up to 93 able model available.
p bar up to 16 Applications: Handling of chemically aggressive liquids, also slightly contaminated
T °C up to +300 or with a low solids content, in the chemical and petrochemical industry.
n min -1 up to 2,900

A Hyamaster • hyatronic Reference no. 2711.5 also available in 60 Hz

Rainwater harvesting systems

Hya-Rain / Hya-Rain N Rainwater harvesting system with one pump

Rp 1 Design: Ready-to-connect package rainwater harvesting system.


Q m3/h up to 4
Hm up to 43 Applications: Rainwater and service water utilization, irrigation and spray
p bar up to 6 irrigation systems.
T °C up to +35
n min -1 up to 2,800

A Reference no. 5602.51

Hya-Rain-Duo Rainwater harvesting system with two pumps

Rp 1 1/ 4 Design: Ready-to-connect package rainwater harvesting system.


Q m3/h up to 8
Hm up to 55 Applications: Rainwater and service water utilization, irrigation and spray
p bar up to 10 irrigation systems.
T °C up to +35
n min -1 up to 2,800

A Reference no. 5602.52

A Automation possible 25
Rainwater harvesting systems

Ixo RWS Submersible motor pump for floating-suction water intake

Rp 1 1/ 4 Design: Fully or partly submerged, multistage, close-coupled centrifugal pump, low-


Q m3/h up to 5 level inlet, suction bell with floating-suction water intake.
Hm up to 65 Applications: Water supply, spray irrigation and small irrigation systems, small
p bar - washing plants, rainwater harvesting systems, water extraction from tanks, cisterns
T °C up to +35 and bodies of water.
n min -1 up to 2,900

A Reference no. 5603.5

Domestic water supply systems with automatic control


unit / swimming pools

Multi Eco Multistage, self-priming centrifugal pump

Rp 1-11/4 Design: Multistage, self-priming centrifugal pump in close-coupled design.


Q m3/h up to 8 Applications: Single- or two-family houses, agricultural facilities, spray irrigation
Hm up to 54 and irrigation systems, washing plants, water supply and rainwater harvesting sys-
p bar up to 10 tems.
T °C up to +50
n min -1 up to 2,800

A Switchgears Reference no. 5180.5

Multi Eco-Pro Multistage, self-priming centrifugal pump with automatic control unit

Rp 1-11/4 Design: Multistage, self-priming centrifugal pump in close-coupled design, with


Q m3/h up to 8 power supply cable, plug and automatic control unit Controlmatic E switching the
Hm up to 54 pump on and off as consumers are opened / closed and protecting the pump
p bar up to 10 against dry running.
T °C up to +50 Applications: Single- or two-family houses, agricultural facilities, spray irrigation
n min -1 up to 2,800 and irrigation systems, washing plants, water supply and rainwater harvesting sys-
tems.

A Switchgears Reference no. 5182.5

Multi Eco-Top Domestic water supply system

Rp 1-11/4 Design: Multistage, self-priming centrifugal pump in close-coupled design incl.


Q m3/h up to 8 accumulator with replaceable membrane in drinking water quality, total volume 20
Hm up to 54 or 50 l, pressure switch for automatic pump operation and 1.5 m power supply
p bar up to 7 cable.
T °C up to +50 Applications: Single- or two-family houses, agricultural facilities, spray irrigation
n min -1 up to 2,800 and irrigation systems, washing plants, water supply and rainwater harvesting sys-
tems.

A Reference no. 5181.5

26 A Automation possible
Domestic water supply systems with automatic control
unit / swimming pools

Movitec VE High-pressure in-line pump in close-coupled design

Rp 1 1/ 2 Design: Multistage, vertical (horizontal installation upon request) high-pressure


Q m3/h up to 12 centrifugal pump, with suction and discharge nozzles of identical nominal
Hm up to 70 diameters arranged opposite to each other (in-line design).
p bar up to 10 Applications: Single- or two-family houses, agricultural facilities, spray irrigation
T °C up to +60 and irrigation systems, washing plants, water supply and rainwater harvesting sys-
n min -1 up to 2,900 tems, pressure boosting, hot water and cooling water recirculation, fire-fighting sys-
tems.

A Reference no. 1798.5 also available in 60 Hz

Ixo Submersible motor pump

Rp 1 1/ 4 Design: Fully or partly submerged, multistage, close-coupled centrifugal pump


Q m3/h up to 8 (min. immersion depth 0.1 m), low-level inlet, suction strainer with a max. mesh
Hm up to 65 size of 2.5 mm.
p bar - Applications: Water supply, spray irrigation and irrigation systems, washing plants,
T °C up to +35 rainwater harvesting systems, water extraction from wells, tanks and cisterns.
n min -1 up to 2,900

A Switchgears Reference no. 2146.5

Filtra Recirculating pump for swimming pool filtering systems

Rp 2 Design: Self-priming, single-stage, close-couped centrifugal pump.


Q m3/h up to 36 Applications: Handling of clean or slightly contaminated water, swimming pool
Hm up to 21 water with a chlorine content of up to 0.3 %, ozonized swimming pool water with
p bar up to 2,5 a salt content of up to 7 ‰.
T °C up to +35
n min -1 up to 2,800

A Reference no. 2127.5

Pressure boosting units

Hya-Solo E / D / DV Pressure boosting / fire fighting unit, 1 pump

Rp 11/4-2 Design: Fully automatic, package single-pump unit with 8 l membrane-type accu-
Q m3/h up to 65 mulator, pressure-controlled start-up and flow-controlled shutdown.
Hm up to 150 Applications: Fire-fighting systems for residential buildings, department stores and
p bar up to 16 industrial plants, water supply systems for residential and office buildings, irrigation /
T °C up to +70 spray irrigation and rainwater harvesting systems, service water supply systems in
n min -1 up to 2,900 trade and industry.

A Reference no. 1951.5

A Automation possible 27
Pressure boosting units

Hya-Eco Pressure boosting / fire-fighting unit, 2 to 3 pumps

Rp 2 Design: Fully automatic package pressure boosting unit, with 2 to 3 vertical high-
Q m3/h up to 45 pressure pumps, fully electronic control to ensure the required supply pressure, stan-
Hm up to 80 dard version with volt-free contact for general fault indication and live-zero monitor-
p bar up to 10 ing of the connected sensors, configuration and functions to DIN 1988, part 5.
T °C up to +70 Applications: Residential buildings, hospitals, office buildings, hotels, department
n min -1 up to 2,850 stores, industry, etc.

A Reference no. 1967.5

Hyamat K Pressure boosting / fire-fighting unit, 2 to 6 pumps

DN 65 - 200 Design: Fully automatic package pressure boosting unit, with 2 to 6 vertical high-
Q m3/h up to 360 pressure pumps, fully electronic control to ensure the required supply pressure, with
Hm up to 160 volt-free contact for general fault indication and live-zero monitoring of the con-
p bar up to 16 nected sensors, configuration and functions to DIN 1988, part 5.
T °C up to +70 Applications: Residential buildings, hospitals, office buildings, hotels, department
n min -1 up to 2,900 stores, industry, etc.

A hyatronic Reference no. 1952.5

Hyamat V Pressure boosting / fire-fighting unit with continuously variable speed adjustment of one pump

DN 65 - 200 Design: Fully automatic package pressure boosting unit, with 2 to 6 vertical high-
Q m3/h up to 360 pressure pumps and continuously variable speed adjustment of one pump for fully
Hm up to 160 electronic control of the required supply pressure, configuration and functions to
p bar up to 16 DIN 1988, part 5.
T °C up to +70 Applications: Pressure boosting in residential buildings, hospitals, office buildings,
n min -1 up to 2,900 hotels, department stores, industry, etc.

A hyatronic Reference no. 1953.51

Hyamat VP Pressure boosting / fire-fighting unit with continuously variable speed adjustment of each pump

DN 65 - 150 Design: Fully automatic package pressure boosting unit, with 2 to 4 vertical high-
Q m3/h up to 200 pressure pumps and continuously variable speed adjustment of each pump for fully
Hm up to 130 electronic control of the required supply pressure, configuration and functions to
p bar up to 16 DIN 1988, part 5.
T °C up to +70 Applications: Pressure boosting in residential buildings, hospitals, office buildings,
n min -1 up to 2,900 hotels, department stores, industry, etc.

A hyatronic Reference no. 1953.52

Hyamat IK, IV, IVP Pressure boosting / fire-fighting unit for industrial applications

DN 100 - 200 Design: Fully automatic package pressure boosting unit, with 2 to 4 vertical high-
Q m3/h up to 640 pressure pumps and fully electronic control to ensure the required supply pressure,
Hm up to 160 configuration and functions to DIN 1988, part 5.
p bar up to 16 Applications: Handling of service water, fire-fighting water and cooling water not
T °C up to +70 chemically or mechanically aggressive to the pump materials in industry, etc.
n min -1 up to 2,900

A Reference no. 1950.5

28 A Automation possible
Drainage pumps / waste water pumps

Ama® -Drainer 301, 303, 324, 356 Floodable submersible motor pump

Rp 11/4 -11/2 Design: Vertical, fully floodable submersible motor pump in close-coupled design,
Q m3/h up to 17 IP 68, single-stage, with or without level control, max. immersion depth 2 m.
Hm up to 12 Applications: Automatic drainage of pits, shafts, yards and cellars subject to a
p bar - flooding risk, lowering of surface water levels, dewatering, drainage of under-
T °C up to +35 ground passages, water extraction from rivers and reservoirs.
n min -1 up to 2,800

A Switchgears Reference nos. 2331.51/2331.52

Ama® -Drainer 405, 435, 505 Floodable submersible motor pump

Rp 11/2 -2 Design: Vertical, fully floodable submersible motor pump in close-coupled design,
Q m3/h up to 50 IP 68, single-stage, with or without level control, max. immersion depth 10 m.
Hm up to 21 Applications: Automatic drainage of pits, shafts, yards and cellars subject to a
p bar - flooding risk, lowering of surface water levels, dewatering, drainage of under-
T °C up to +40 ground passages, water extraction from rivers and reservoirs, disposal of highly
n min -1 up to 2,800 contaminated, fibre-containing water.

A Switchgears Reference no. 2331.53

Ama® -Drainer 80, 100 Floodable submersible motor pump

Rp / DN 21/2 / 100 Design: Vertical, fully floodable submersible motor pump in close-coupled design,
Q m3/h up to 130 IP 68, single-stage, with or without level control, max. immersion depth 10 m.
Hm up to 26 Applications: Automatic drainage of pits, shafts, yards and cellars subject to a
p bar - flooding risk, lowering of surface water levels, dewatering, drainage of under-
T °C up to +50 ground passages, water extraction from rivers and reservoirs.
n 1/min -1 up to 2,800

A Switchgears Reference no. 2331.54

Ama® -Porter F / S / ICS Floodable submersible motor pump

DN 50 - 65 Design: Vertical, fully floodable submersible waste water pump in close-coupled


Q m3/h up to 40 design (cast iron variant), single-stage, without explosion protection.
Hm up to 21 Applications: Handling of all types of waste water.
p bar -
T °C up to +40
n min -1 up to 2,900

A Switchgears Reference nos. 2541.51/2539.51/2539.52/2539.53

Rotex Waste water pump

Rp 11/4 -2 Design: Vertical, single-stage centrifugal pump with discharge to the top and par-
Q m3/h up to 24 allel with the pump shaft, pump foot designed as suction strainer. Pump and motor
Hm up to 14 are rigidly connected by a support pipe, ready to be plugged in, with 1.5 m power
p bar - supply cable and level switch.
T °C up to +90 Applications: Automatic disposal of waste water from buildings, pits and tanks,
n min -1 up to 2,900 lowering of surface water levels and drainage.

A Switchgears Reference no. 2322.5

A Automation possible 29
Drainage pumps / waste water pumps

MK / MKY Waste water, condensate and heat transfer liquid pump

Rp / DN 2 / 50 Design: Vertical submersible pump with three-channel impeller, volute casing


Q m3/h up to 36 designed as suction strainer.
Hm up to 19 Applications: Handling of condensate and heat transfer liquids below the boiling
p bar - point, condensate return systems, primary and secondary heating circuits, direct
T °C up to +200 installation in heating tanks or heat exchangers in the secondary circuits of heat
n min -1 up to 2,800 transfer systems (MKY).

A Switchgears Reference no. 2324.5

Lifting units / collecting tanks

Ama® -Drainer-Box Automatic waste water lifting unit

DN 40 - 50 Design: Stable above-floor or impact-resistant underfloor plastic collecting tank


Q m3/h up to 35 with floor drain and odour trap, both variants with Ama®-Drainer submersible
Hm up to 21 motor pump starting and stopping automatically and swing check valve.
p bar - Applications: Wash-basins, showers, washing machines, garage gateways, base-
T °C up to +40 ments, rooms subject to a flooding risk, etc.
n min -1 up to 2,800

A Switchgears Reference no. 2331.55

Ama-Sani® Small sewage lifting unit for a single toilet

DN 25 - 32 Design: Automatic, small plug-in sewage lifting unit with cutter, integrated swing
Q m3/h up to 5 check valve and activated charcoal filter.
Hm up to 10 Applications: Disposal of water from a single toilet and in addition from a lavatory
p bar - basin, urinal, shower or bidet in basements, guest rooms, weekend houses, work-
T °C up to +35 shops or hobby rooms or for subsequent installation in refurbished or revamped
n min -1 up to 2,900 buildings.

A Reference no. 2318.5

mini-Compacta® Submersible sewage lifting unit

DN 32 - 100 Design: Submersible single or duplex sewage lifting unit for automatic disposal of
Q m3/h up to 50 domestic sewage and faeces below the backwash level.
Hm up to 18 Applications: Basement flats, bars, basement party rooms and saunas, cinemas
p bar - and theatres, department stores and hospitals, hotels, restaurants, schools, etc.
T °C up to +35
n min -1 up to 2,800

A Switchgears Reference no. 2317.51

30 A Automation possible
Lifting units / collecting tanks

Compacta® Submersible sewage lifting unit

DN 80 - 100 Design: Submersible single or duplex sewage lifting unit for automatic disposal of
Q m3/h up to 135 sewage and faeces below the backwash level.
Hm up to 24 Applications: Basement flats, bars, basement party rooms and saunas, cinemas
p bar - and theatres, department stores and hospitals, hotels, restaurants, schools, public
T °C up to +65 buildings, industrial plants, joint sewage disposal for rows of houses, etc.
n min -1 up to 2,800

A Switchgears Reference no. 2317.52

Evamatic-Box Sewage lifting unit

DN 50 - 65 Design: Single or duplex sewage lifting unit with 1 or 2 Ama®-Porter submersible


Q m3/h up to 40 waste water pumps with free-flow impeller (F) or cutter (S), to EN 12050-1.
Hm up to 21 Applications: Disposal of domestic waste water and sewage.
p bar -
T °C up to +40
n min -1 up to 2,900

A Reference no. 2319.51

Evamatic-Box ICS Sewage lifting unit

DN 50 - 65 Design: Single or duplex sewage lifting unit with 1 or 2 Ama®-Porter ICS sub-
Q m3/h up to 40 mersible waste water pumps with free-flow impeller (F) or cutter (S) and ICS control
Hm up to 21 system.
p bar - Applications: Disposal of domestic waste water and sewage.
T °C up to +40
n min -1 up to 2,900

A Reference no. 2319.52

Ama® -Porter CK Pumping Station Pumping station, plastic collecting tank with Ama®-Porter

DN 50 - 65 Design: Ready-to-connect package single or dual pumping station with PE-LLD


Q m3/h up to 40 (polyethylene) collecting tank for underground installation. Equipped with one or
Hm up to 21 two Ama®-Porter submersible waste water pumps without explosion protection.
p bar - Collecting tank design to DIN 1986-100 and EN 752 / EN 476.
T °C up to +40 Applications: Renovation of premises, sewage disposal in various sectors, joint
n min -1 up to 2,900 sewage disposal for several residential units, pumped drainage.

A Reference no. 2334.51

Amarex N CK Pumping Station Pumping station, plastic collecting tank with Amarex N

DN 50 - 65 Design: Ready-to-connect package single or dual pumping station with PE-LLD


Q m3/h up to 190 (polyethylene) collecting tank for underground installation. Equipped with one or
Hm up to 49 two Amarex N submersible waste water pumps, also available with explosion pro-
p bar - tection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476.
T °C up to +40 Applications: Renovation of premises, sewage disposal in various sectors, joint
n min -1 up to 2,900 sewage disposal for several residential units, pumped drainage.

Reference no. 2334.52 also available in 60 Hz

A Automation possible 31
Submersible motor pumps

Amarex N Submersible motor pump DN 50 to 100

DN 50 - 100 Design: Vertical, single-stage submersible motor pump, for wet installation, sta-
Q m3/h up to 190 tionary and transportable design. Amarex N pumps are floodable, single-stage,
Hm up to 49 single-entry close-coupled units which are not self-priming.
p bar - Applications: Handling of all types of waste water, especially untreated sewage
T °C up to +40 containing long fibres and solid substances, fluids containing gas / air, as well as
n min -1 up to 2,900 raw, activated and digested sludge, dewatering / water extraction, drainage of
rooms and surfaces subject to a flooding risk.

A Switchgears Reference no. 2563.5 also available in 60 Hz

Amarex KRT Submersible motor pump DN 40 to DN 700

DN 40 - 700 Design: Vertical, single-stage submersible motor pump in close-coupled design,


Q m3/h up to 10,800 various impeller types, for wet installation, stationary and transportable design.
Hm up to 100 Applications: Handling all types of waste water in waste water engineering and
p bar - industry, especially untreated sewage containing long fibres and solid substances,
T °C up to +60 fluids containing gas / air, as well as raw, activated and digested sludge.
n min -1 up to 2,900

A PumpExpert • Hyamaster • hyatronic • Switchgears Reference no. 2553.5 also available in 60 Hz

Amarex KRT, dry-installed Submersible motor pump DN 100 to DN 700

DN 100 - 700 Design: Vertical, single-stage submersible motor pump in close-coupled design,
Q m3/h up to 10,000 various impeller types, dry installation.
Hm up to 100 Applications: Handling of all types of waste water in waste water engineering and
p bar up to 10 industry, especially sewage containing long fibres and solid substances, fluids con-
T °C up to +40 taining gas / air, as well as raw, activated and digested sludge.
n min -1 up to 1,450

A PumpExpert • Hyamaster • hyatronic Reference no. 2553.57 also available in 60 Hz

32 A Automation possible
Submersible pumps in discharge tubes

Amacan K Submersible motor pump with non-clogging impeller

DN 700 - 1,400 Design: Wet-installed submersible motor pump with non-clogging impeller, single-
Q m3/h up to 7,200 stage, single-entry, for installation in discharge tubes, explosion protection to ATEX
Hm up to 30 II G2 T3.
p bar - Applications: Handling of pre-cleaned, chemically neutral waste water, industrial
T °C up to +40 effluents and sewage, fluids not containing any stringy substances pre-treated by
n min -1 up to 980 screens and sills, as waste water, mixed water and activated sludge pump in efflu-
ent treatment plants, irrigation and drainage pumping systems.

A PumpExpert • Hyamaster • hyatronic Reference no. 1579.5 also available in 60 Hz

Amacan P Submersible motor pump with axial propeller

DN 500 - 1,500 Design: Wet-installed, submersible motor pump with axial propeller in ECB design
Q m3/h up to 25,200 for installation in discharge tubes, single-stage, single-entry, explosion protection to
Hm up to 12 ATEX II G2 T3.
p bar - Applications: Irrigation and drainage pumping stations, stormwater pumping sta-
T °C up to +40 tions, handling of raw and clean water in water and effluent treatment plants, of
n min -1 up to 1,450 cooling water in power stations and industrial plants, industrial water supply sys-
tems, water pollution and flood control systems, aquaculture.

A PumpExpert • Hyamaster • hyatronic Reference no. 1580.5 also available in 60 Hz

Amacan S Submersible motor pump with mixed flow impeller

DN 650 - 1,300 Design: Wet-installed submersible motor pump with mixed flow impeller, single-
Q m3/h up to 10,800 stage, for installation in discharge tubes, explosion protection to ATEX II G2 T3.
Hm up to 40 Applications: Handling of water without stringy substances in irrigation and
p bar - drainage pumping systems, general water supply systems, water pollution and flood
T °C up to +30 control systems.
n min -1 up to 1,450

A PumpExpert • Hyamaster • hyatronic Reference no. 1589.5 also available in 60 Hz

Mixers / agitators / tank cleaning units

Amamix Submersible mixer

Propeller ø (mm) 215 - 600 Design: Horizontal submersible mixer with self-cleaning ECB propeller, close-
Max. installation depth (m) 30 coupled design, direct drive or with gear unit, explosion protection to ATEX II G2 T3
Hm - or T4.
p bar - Applications: Mixing, homogenizing and thickening of municipal and industrial
T °C up to +40 waste water and sludge.
n min -1 up to 1,400

Reference no. 1592.55 also available in 60 Hz

A Automation possible 33
Mixers / agitators / tank cleaning units

Amaprop Submersible agitator

Propeller ø (mm) 1,200 - 2,500 Design: Horizontal submersible agitator with self-cleaning ECB propeller, close-
Max. installation depth (m) 30 coupled design, equipped with coaxial spur gear, explosion protection to ATEX II G2
Hm - T3 or T4.
p bar - Applications: Circulating, keeping in suspension and dispersing of municipal and
T °C up to +40 industrial waste water and sludges.
n min -1 up to 109

Reference no. 1592.505

Amajet Cleaning system

DN 100 - 150 Design: Stationary or portable unit with horizontal or vertical submersible motor
Q m3/h up to 195 propulsive jet pump with non-clogging free-flow impeller. Motor rating 5.5 to 27
Hm - kW. Available variants: Amajet, SewerAmajet, SwingAmajet, MultiAmajet.
p bar - Applications: Cleaning of stormwater tanks and storage sewers.
T °C up to +40
n min -1 up to 1,450

Reference no. 1574.5

Amaline Submersible motor recirculation pump

DN 300 - 800 Design: Wet-installed, horizontal propeller pump with submersible motor, equipped
Q m3/h up to 5,400 with spur gear or direct drive, ECB propeller with 3 rigid, fibre-repellent blades,
Hm up to 2 boltfree connection to the discharge pipe, explosion protection to ATEX II G2 T3 or
p bar - T4.
T °C up to +40 Applications: Recirculation of activated sludge in waste water treatment systems.
n min -1 up to 960

Reference no. 1594.5 also available in 60 Hz

Pumps for solids-laden fluids /


positive displacement pumps

Sewatec / Sewabloc Dry-installed volute casing pump

DN 50 - 700 Design: Horizontal or vertical volute casing pump with free-flow, single-vane and
Q m3/h up to 10,000 multi-vane impellers, discharge flange to DIN and ANSI standards. Design to ATEX.
Hm up to 93 Applications: Handling of sewage and all types of waste water in waste water
p bar up to 10 management and industry.
T °C up to +70
n min -1 up to 2,900

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference nos. 2580.5/2580.45/2580.46/2580.56 also available in 60 Hz

34 A Automation possible
Pumps for solids-laden fluids /
positive displacement pumps

KWP / KWP-Bloc Non-clogging impeller centrifugal pump / close-coupled unit

DN 40 - 800 Design: Horizontal, radially split volute casing pump in back pull-out or close-
Q m3/h up to 1,300 coupled design, single-stage, single-entry, available with various impeller types:
Hm up to 100 non-clogging impeller, open multi-vane impeller, free-flow impeller. Design to ATEX.
p bar up to 10 Applications: Handling of pre-treated sewage, waste water, all types of slurries
T °C up to +280 without stringy substances and pulps up to 5 % bone dry with a maximum density
n min -1 up to 2,900 of 1.1 kg/dm3.

A PumpExpert • Hya-Drive • Hyamaster • hyatronic Reference nos. 2361.5/2362.5/2361.450/2361.453/2361.460 also available in 60 Hz

Getec / Getecbloc Progressive cavity pump

DN 25 - 250 Design: Horizontal, self-priming, dry-installed, positive displacement pump in pro-


Q m3/h up to 300 gressive cavity design, long- or close-coupled, with single helical rotor and double
Hm up to 240 helical stator made of elastomer.
p bar up to 24 Applications: Handling, disposal and treatment of sludge (incl. gaseous and highly
T °C up to 100 viscous sludges with high solids / dry substance contents) in effluent treatment
n min -1 up to 2,000 plants and industrial waste water systems, especially suitable as variable speed
dosing pump.

Reference no. 2590.5

Self-priming pumps

Etaprime L Self-priming pump for pure or contaminated liquids

DN 25 - 125 Design: Horizontal, long-coupled, self-priming volute casing pump in back pull-out
Q m3/h up to 159 design, single-stage, with open multi-vane impeller. Design to ATEX.
Hm up to 85 Applications: Handling of pure, contaminated or aggressive liquids not containing
p bar up to 10 abrasive substances and / or solids.
T °C up to +90
n min -1 up to 2,900

Reference no. 2745.5 also available in 60 Hz

Etaprime B / BN Self-priming close-coupled pump for pure or contaminated liquids

DN 25 - 100 Design: Horizontal, self-priming volute casing pump, single-stage, with open multi-
Q m3/h up to 135 vane impeller, in close-coupled design, with common pump and motor shaft (B) or
Hm up to 78 rigidly connected (BN). Design to ATEX.
p bar up to 10 Applications: Handling of pure, contaminated or aggressive liquids not containing
T °C up to +90 abrasive substances and / or solids.
n min -1 up to 2,900

Reference no. 2746.5 also available in 60 Hz

A Automation possible 35
Submersible borehole pumps

S 100 B / UPA 100 C Submersible borehole pump

DN 100 Design: Multistage centrifugal pump in ring-section design, made of stainless steel
Q m3/h up to 16 and plastic (S 100 B) or stainless steel (UPA 100 C) for well diameters of 100 mm (4
Hm up to 400 inches) and above, available with single-phase a.c. motor or three-phase motor
p bar - with motor lead.
T °C up to +30 Applications: Domestic water supply, irrigation and spray irrigation systems, low-
n min -1 up to 2,900 ering of ground water levels, fire protection systems, cooling circuits, fountains,
pressure boosting and air-conditioning systems.

A Switchgears Reference no. 3400.5 also available in 60 Hz

UPA 150 S Submersible borehole pump

DN 150 Design: Single- or multistage centrifugal pump in ring-section design, single-entry,


Q m3/h up to 85 for vertical installation.
Hm up to 320 Applications: Handling of clean and slightly contaminated water in general water
p bar - supply, irrigation and spray irrigation systems, maintaining / lowering of ground
T °C up to +50 water levels.
n min -1 up to 2,900

A Hyamaster • hyatronic • Switchgears Reference no. 3400.5 also available in 60 Hz

UPA 200, 200 B, 250 C Submersible borehole pump

DN 200 - 250 Design: Single- or multistage centrifugal pump in ring-section design for vertical
Q m3/h up to 840 installation. Non-return valve integrated in the discharge nozzle.
Hm up to 460 Applications: Handling of clean or slightly contaminated water in general water
p bar - supply, irrigation and spray irrigation systems, maintaining / lowering of ground
T °C up to +50 water levels, fountains, pressure boosting systems, in mines, sprinkler systems,
n min -1 up to 2,900 emergency water supply systems, etc.

A Hyamaster • hyatronic • Switchgears Reference no. 3400.5 also available in 60 Hz

UPA 300, 350 Submersible borehole pump

DN 300 - 350 Design: Single- or multistage, single-entry centrifugal pump in ring-section design
Q m3/h up to 840 for vertical or horizontal installation. Non-return valve or connection branch on
Hm up to 480 option. Mixed flow hydraulic systems available with reduced impeller diameters.
p bar - Both versions with threaded or flanged end.
T °C up to +50 Applications: Handling of clean or slightly contaminated water in general water
n min -1 up to 2,900 supply, irrigation and spray irrigation systems, maintaining / lowering of ground
water levels, in mines, fountains, etc.

A Hyamaster • hyatronic • Switchgears Reference no. 3400.5 also available in 60 Hz

UPZ, BSX-BSF Submersible borehole pump

DN > 350 Design: Single- or multistage, single-entry (BSX-BSF) or double-entry (UPZ) cen-
Q m3/h up to 2,200 trifugal pump in ring-section design for vertical or horizontal installation.
Hm up to 1,500 Applications: Handling of clean or slightly contaminated water, maintaining / low-
p bar - ering of ground water levels, in mines.
T °C up to +50
n 1/min -1 up to 2,900

Reference no. 3470.021 also available in 60 Hz

36 A Automation possible
High-pressure pumps, fixed / variable speed

Movitec V / LHS High-pressure in-line pump

DN 32 - 100 Design: Multistage, vertical high-pressure centrifugal pump in ring-section design


Q m3/h up to 75 with suction and discharge nozzles of identical nominal diameters arranged oppo-
Hm up to 401 site to each other (in-line design), close-coupled. Design to ATEX.
p bar up to 40 Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting
T °C up to +120 and pressure boosting systems, hot water and cooling water recirculation, boiler
n min -1 up to 2,900 feed systems, etc.

A Hya-Drive/PumpDrive • Hyamaster • hyatronic Reference no. 1798.5 also available in 60 Hz

Movitec PumpDrive High-pressure in-line pump with frequency inverter

DN 32 - 100 Design: Multistage, vertical high-pressure centrifugal pump in ring-section design


Q m3/h up to 75 with suction and discharge nozzles of identical nominal diameters arranged oppo-
Hm up to 401 site to each other (in-line design), close-coupled. PumpDrive self-cooling frequency
p bar up to 40 inverter. Design to ATEX.
T °C up to +120 Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting
n 1/min -1 up to 2,900 and pressure boosting systems, hot water and cooling water recirculation, boiler
feed systems, etc.

A Hya-Drive/PumpDrive • Hyamaster • hyatronic Reference no. 1798.5 also available in 60 Hz

Multitec High-pressure pump in ring-section design

DN 32 - 150 Design: Multistage horizontal centrifugal pump in ring-section design, long-


Q m3/h up to 850 coupled and close-coupled variant, with axial or radial suction nozzle, cast radial
Hm up to 630 impellers. Design to ATEX.
p bar up to 63 Applications: Water and drinking water supply systems, general industry, pressure
T °C up to +200 boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting,
n min -1 up to 2,900 reverse osmosis and washing plants, snow guns, etc.
Higher values available upon request

A PumpExpert • Hya-Drive/PumpDrive • Hyamaster • hyatronic Reference no. 1777.5 also available in 60 Hz

HGM-RO High-pressure pump in ring-section design

DN 65 - 200 Design: Horizontal, radially split, product-lubricated, multistage ring-section pump


Q m3/h up to 1,150 with radial impellers, axial inlet, single-entry.
Hm up to 950 Applications: Seawater desalination systems using reverse osmosis, chilled water
p bar up to 120 applications.
T °C up to +40
n min -1 up to 2,900
Higher values available upon request

Reference no. 1582.022 also available in 60 Hz

A Automation possible 37
Axially split pumps

Omega Axially split volute casing pump DN 80-350

DN 80 - 350 Design: Single-stage, axially split volute casing pump for horizontal or vertical
Q m3/h up to 2,880 installation, with double-entry radial impeller, mating flanges to DIN, ISO, BS or
Hm up to 170 ANSI.
p bar up to 25 Applications: Handling of raw, pure and service water as well as seawater in
T °C up to +105 water treatment plants, irrigation and drainage pumping stations, power stations,
n min -1 up to 2,900 fire-fighting systems, shipbuilding and the petrochemical industry.
Higher values available upon request

A PumpExpert • Hyamaster Reference no. 1384.5 also available in 60 Hz

RDLO Axially split volute casing pump DN 350-700

DN 350 - 700 Design: Single-stage, axially split volute casing pump for horizontal or vertical
Q m3/h up to 10,000 installation with double-entry radial impeller, mating flanges to DIN, ISO, BS or
Hm up to 240 ANSI.
p bar up to 25 Applications: Handling of raw, pure and service water as well as seawater in
T °C up to +105 water treatment plants, irrigation and drainage pumping stations, in power sta-
n min -1 up to 1,450 tions, fire-fighting systems, shipbuilding and the petrochemical industry, in refiner-
Higher values available upon request ies, pipelines and tank farms; handling of crude oil and refinery intermediates.

A PumpExpert • Hyamaster Reference nos. 1385.51/1387.5 also available in 60 Hz

Stainless steel pumps for the food industry

Vitachrom Hygienic pump in close-coupled design

DN 50 - 125 Design: Easy-to-service annular casing pump, close-coupled design with standard-
Q m3/h up to 340 ized motor, all wetted pump parts made of stainless steel, suitability for handling
Hm up to 100 foodstuffs certified by TNO according to EHEDG requirements (TNO G96-143 cer-
p bar up to 12 tificate).
T °C up to +110 Applications: Hygienic handling of fluids in the food and beverages industry and
n min -1 up to 2,900 in the chemical industry.

A Hya-Drive • Hyamaster • hyatronic Reference no. 1966.5 also available in 60 Hz

38 A Automation possible
Pumps for power station conventional islands

CHTA / CHTC / CHTD Boiler feed pump

DN 100 - 500 Design: Horizontal, high-pressure barrel-type pump with radial impellers, multi-
Q m3/h up to 3,700 stage, single-entry, with flanges / weld end nozzles to DIN and ANSI.
Hm up to 5,300 Applications: Handling of feed water and condensate in power stations and indus-
p bar up to 560 trial facilities, generation of pressurized water for bark peeling machines and
T °C up to +210 descaling equipment.
n min -1 up to 6,750
Higher values available upon request

Reference no. 1860.1 also available in 60 Hz

HGB / HGC / HGD Boiler feed pump

DN 40 - 400 Design: Horizontal, radially split, multistage ring-section pump with radial
Q m3/h up to 2,300 impellers, single- or double-entry.
Hm up to 5,300 Applications: Handling of feed water and condensate in power stations and indus-
p bar up to 560 trial facilities, generation of pressurized water for bark peeling machines, descaling
T °C up to +210 equipment, snow guns, etc.
n min -1 up to 7,000
Higher values available upon request

Reference no. 1850.02 also available in 60 Hz

HGM Boiler feed pump

DN 25 - 100 Design: Horizontal, radially split, product-lubricated, multistage ring-section pump


Q m3/h up to 274 with radial impellers, axial and radial single-entry inlet.
Hm up to 1,400 Applications: Handling of feed water in power stations, boiler feed water and
p bar up to 140 condensate in industrial facilities.
T °C up to +160
n min -1 up to 3,600
Higher values available upon request

Reference no. 1856.02 also available in 60 Hz

YNK / KRHA Booster pump

DN 125 - 600 Design: Horizontal, radially split, single-stage, double-entry boiler feed booster
Q m3/h up to 3,700 pump (booster system) with single or double cast steel volute casing.
Hm up to 280 Applications: Handling of feed water in power stations and industrial facilities.
p bar up to 40
T °C up to +210
n min -1 up to 1,800
Higher values available upon request

Reference no. 1130.5 also available in 60 Hz

RHD Feed water pump

DN 250 - 400 Design: Horizontal, single-stage, double-entry feed water pump, cast and forged
Q m3/h up to 6,500 variant.
Hm up to 1,000 Applications: Handling of feed water in steam generation systems of nuclear
p bar up to 150 power stations.
T °C up to +210
n min -1 up to 6,500
Higher values available upon request

also available in 60 Hz

A Automation possible 39
Pumps for power station conventional islands

MBH Booster pump

DN 125 - 600 Design: Horizontal, single-stage, double-entry feed water booster pump (booster
Q m3/h up to 6,500 system), cast and forged variant.
Hm up to 1,000 Applications: Handling of feed water in steam generation systems of nuclear
p bar up to 150 power stations.
T °C up to +210
n min -1 up to 3,500
Higher values available upon request

also available in 60 Hz

LUV / LUVA / LUVB Boiler recirculation pump

DN 100 - 550 Design: Vertical spherical casing pump, radial impellers, single- or double-stage,
Q m3/h up to 7,000 single-entry. Suitable for very high inlet pressures and temperatures. Integrated wet
Hm up to 275 rotor motor to VDE / IEEE specifications. Product-lubricated bearings, no need for oil
p bar up to 320 supply systems. Design to TRD.
T °C up to +420 Applications: Hot water recirculation in forced-circulation, forced-flow and com-
n min -1 up to 3,600 bined-circulation boilers for very high pressures. Waste heat recovery in steel works.
Higher values available upon request

Reference no. 0361.033 also available in 60 Hz

WKT / WKTA / WKTB Condensate pump

DN 40 - 300 Design: Vertical, multistage, can-type ring-section pump with radial and mixed flow
Q m3/h up to 1,800 impellers. Single- and double-entry suction impellers, flanges to DIN or ANSI. The
Hm up to 340 can is arranged in a pit below the installation floor. The pump is connected with the
p bar up to 40 structure by means of a baseplate.
T °C up to +100 Applications: Handling of condensate in power stations and energy systems.
n min -1 up to 1,800
Higher values available upon request

Reference no. 0361.033 also available in 60 Hz

SEZ / PHZ / PNZ Cooling water pump

DN 700 - 2400 Design: Vertical tubular casing pump with open mixed flow impeller (SEZ), mixed
Q m3/h up to 65,000 flow propeller (PHZ) or axial propeller (PNZ). Pump inlet with bellmouth or suction
Hm up to 48 elbow, pull-out design available, discharge nozzle arranged above or below floor,
p bar up to 10 flanges to DIN or ANSI standards available.
T °C up to +40 Applications: Handling of raw, pure, service and cooling water in industry, water
n min -1 up to 980 supply systems, in power stations and seawater desalination plants.
Higher values available upon request

Reference no. 1471.02 also available in 60 Hz

SNW / PNW Cooling water pump

DN 350 - 700 Design: Vertical tubular casing pump with mixed flow impeller (SNW) or axial pro-
Q m3/h up to 9,000 peller (PNW), with maintenance-free Residur® shaft bearings, discharge nozzle
Hm up to 50 arranged above or below floor.
p bar up to 10 Applications: Irrigation and drainage systems, stormwater pumping stations, hand-
T °C up to +60 ling of raw and pure water, water supply systems, handling of cooling water.
n min -1 up to 1,500
Higher values available upon request

Reference nos. 1481.5/1591.5 also available in 60 Hz

40 A Automation possible
Pumps for power station conventional islands

SPY Cooling water pump

DN 350 - 1200 Design: Long-coupled, single-stage volute casing pump in back pull-out design.
Q m3/h up to 21,600 Applications: Drainage, irrigation and water supply systems, handling of conden-
Hm up to 50 sate, cooling water, service water, etc.
p bar up to 10
T °C up to +105
n min -1 up to 1,480
Higher values available upon request

Reference no. 2384.51 also available in 60 Hz

Pumps for power station nuclear islands

RER Reactor coolant pump

DN up to 800 Design: Vertical, single-stage reactor coolant pump with forged annular casing
Q m3/h up to 40,000 plated on the inside, with diffuser, either with own pump thrust bearing or support-
Hm up to 140 ed by motor bearing.
p bar up to 175 Applications: Reactor coolant recirculation in nuclear power stations (PWR).
T °C up to +350
n min -1 up to 1,800
Higher values available upon request

also available in 60 Hz

A Automation possible 41
Pumps for power station nuclear islands

RSR Reactor coolant pump

DN up to 600 Design: Vertical, single-stage reactor coolant pump, with cast double volute casing,
Q m3/h up to 9,000 supported by motor bearing.
Hm up to 215 Applications: Reactor coolant recirculation in nuclear power stations (PWR,
p bar up to 125 PHWR).
T °C up to +310
n min -1 up to 1,800
Higher values available upon request

PSR Reactor coolant pump

DN up to 600 Design: Vertical pump set integrated in the reactor pressure vessel, glandless pump
Q m3/h up to 9,000 with leak-free, low-maintenance wet motor.
Hm up to 45 Applications: Reactor coolant recirculation in nuclear power stations (BWR).
p bar up to 75
T °C up to +300
n min -1 up to 2,000
Higher values available upon request

also available in 60 Hz

RHM Pump for safety-related and auxiliary systems

DN up to 150 Design: Horizontal, multistage barrel pull-out pump.


Q m3/h up to 300 Applications: Core flooding, emergency cooling and residual heat removal
Hm up to 2,100 systems, volume control systems, high-pressure charging, control rod drive systems,
p bar up to 220 high- and medium-pressure safety injection systems, auxiliary feed water systems,
T °C up to +180 start-up and shutdown feed water systems.
n min -1 up to 8,000
Higher values available upon request

also available in 60 Hz

RVM Pump for safety-related and auxiliary systems

DN up to 85 Design: Vertical, multistage barrel pull-out pump.


Q m3/h up to 50 Applications: Core flooding, emergency cooling and residual heat removal sys-
Hm up to 2,000 tems, volume control systems, high-pressure safety injection systems.
p bar up to 200
T °C up to +100
n min -1 up to 6,000
Higher values available upon request

also available in 60 Hz

RHR / RVR Pump for safety-related and auxiliary systems

DN up to 500 Design: Horizontal or vertical annular casing pump with forged pressure boundary
Q m3/h up to 6,000 and diffuser.
Hm up to 190 Applications: Core flooding, emergency cooling and residual heat removal sys-
p bar up to 63 tems, ancillary systems, acid feed systems and low-pressure feed systems.
T °C up to +200
n min -1 up to 3,600

also available in 60 Hz

42 A Automation possible
Slurry pumps

FGD Slurry pump

Design: Metal and elastomer-lined pumps with impellers available in a variety of


Q m3/h up to 18,000 corrosion and abrasion resistant alloys. Efficiencies approaching 90% at BEP.
Hm up to 51 Applications: Absorber recirculation in flue gas desulphurization.
p bar up to 7
T °C up to +120

also available in 50 Hz

LSR Slurry pump

Design: Rubber-lined extra heavy duty pump for hardwearing applications.


Q m3/h up to 9,000 Applications: Heavy-duty mill circuit and fine grind slurries, especially copper, iron
Hm up to 40 ore, gold, aggregate and other abrasive fluids.
p bar up to 14
T °C up to +120

also available in 50 Hz

LCV Slurry pump

Design: Heavy-duty vertical pump, with replaceable wet end parts in metal alloys
Q m3/h up to 1,360 and elastomer liners and a very durable mechanical end. The result is a vertical can-
Hm up to 38 tilever sump pump with bottom suction and no submerged bearings.
p bar up to 16
T °C up to +120

also available in 50 Hz

WBC Slurry pump

Design: Pump for heavy-duty, high-pressure applications incorporating state-of-the-


Q m3/h up to 13,600 art hydraulic and wear technologies.
Hm up to 75 Applications: Ore transport lines that are subject to sudden pressure spikes.
p bar up to 28
T °C up to +120

also available in 50 Hz

LSA Slurry pump

Design: Low specific speed volute casing pump (horizontal end suction). The sim-
Q m3/h up to 29,500 ple, single wall construction and heavy section, hard metal wet end combined with
Hm up to 75 the cartridge bearing assembly provides maximum reliability and ease of mainte-
p bar up to 48 nance.
T °C up to +120 Applications: Mineral processing, power generation, handling of aggregate, ash,
tailings, industrial slurries, dredge.

also available in 50 Hz

A Automation possible 43
Slurry pumps

LCC Slurry pump

Design: High-performance, low-maintenance slurry pump recommended for coarse


Q m3/h up to 3,865 or fine particles from solids-laden waste water to aggressive slurries of an abrasive
Hm up to 75 and / or corrosive nature.
p bar up to 16 Applications: Mineral processing, power generation, mine dewatering, handling of
T °C up to +120 aggregate, ash, tailings, industrial slurries, dredge.

also available in 50 Hz

HHD Dredge slurry pump

Design: Hydraulically optimized pump for high head applications.


Q m3/h up to 14,700 Applications: As booster pump and main pump in cutter dredges.
Hm up to 75
p bar up to 20
T °C up to +120

also available in 50 Hz

TBC Dredge slurry pump

Design: Special mechanical construction along with the well-proven HHD type
Q m3/h up to 20,400 hydraulic design.
Hm up to 75 Applications: In cutter dredges.
p bar up to 55
T °C up to +120

also available in 50 Hz

MHD Dredge slurry pump

Design: Pump for efficient pumping in a balanced range of head and flow condi-
Q m3/h up to 29,500 tions.
Hm up to 75 Applications: As hopper dredge suction pump and as main pump on cutter
p bar up to 14 dredges.
T °C up to +120

also available in 50 Hz

LHD Dredge slurry pump

Design: Pump in low-head, high-flow design with special underwater bearing


Q m3/h up to 21,500 seals.
Hm up to 75 Applications: On suction hopper dredges.
p bar up to 19
T °C up to +120

also available in 50 Hz

44 A Automation possible
Control systems

hyatronic K / N Pump control system for cascade starting and stopping

Max. no. of pumps 6 Design: Pump control system in control cabinet for cascade starting and stopping
FI - of up to 6 pumps run on the mains.
kW 22 Applications: Water supply systems.
Voltage V 3∼400

Reference no. 0543.5026

hyatronic S Pump control system for continuously variable speed adjustment

Max. no. of pumps 6 Design: Pump control system in control cabinet for continuously variable speed
FI 1 adjustment of each pump with up to 4 pumps (6 pumps upon request) and one fre-
kW 22 quency inverter.
Voltage V 3∼400 Applications: Heating, ventilation, air-conditioning and water supply systems.

Reference no. 0973.5

hyatronic SP Pump control system for continuously variable speed adjustment

Max. no. of pumps 6 Design: Pump control system in control cabinet for continuously variable speed
FI 1 per pump adjustment of each pump with up to 4 pumps (6 pumps upon request) and fre-
kW 22 quency inverters.
Voltage V 3∼400 Applications: Heating, ventilation, air-conditioning and water supply systems.

Reference no. 0973.5

hyatronic mb Pump control system for continuously variable speed adjustment

Max. no. of pumps 8 Design: Pump control system in control cabinet for asynchronous motors of all
Max. no. of FIs 2 types and makes for controlling and monitoring hydraulic systems.
kW 200 Applications: Heating, ventilation and air-conditioning systems, water supply and
Voltage V 3∼400 drainage systems.

Reference no. 0974.5

Hyamaster ISB Pump control system for continuously variable speed adjustment

Max. no. of pumps 8 Design: Control system for pumps with three-phase motors of all types and makes,
Max. no. of FIs 2 consisting of a KSB controller with display and control panel and all required power
kW 200 components.
Voltage V 3∼400 Applications: Industrial and process engineering circuits, service water supply,
cooling and lubrication, energy supply in cogeneration plants, heat transfer and dis-
trict heating stations, water extraction and treatment, water supply and waste
water disposal.

Reference no. 1961.5

45
Control systems

Hyamaster SPS Pump control system for continuously variable speed adjustment

Max. no. of pumps 4 Design: Control system for pumps with three-phase motors of all types and
FI 1 per pump makes, consisting of a programmable logic controller (PLC) with display and control
kW 650 panel and all required power components housed in a control cabinet.
Voltage V 3∼400 Applications: Process engineering circuits, service water supply, cooling and lubri-
cation systems, cogeneration plants, heat transfer and district heating stations,
water extraction and treatment, water supply and waste water disposal.

Reference no. 1964.5

hyatronic MSB / spc Pump control system for continuously variable speed adjustment

Max. no. of pumps 1 Design: Single-pump control system for continuously variable speed adjustment
FI 1 with integrated frequency inverter.
kW 7.5 Applications: Heating, ventilation, air-conditioning, water supply and drainage sys-
Voltage V 3∼400 tems.

Reference no. 0973.5

Hya-Drive Standardized three-phase IEC motor with integrated frequency inverter for pumps and fans

Max. no. of pumps 6 Design: Integral motor with pump-specific control system, no need for on-site con-
FI 1 per pump/motor trol cabinet.
kW 45 Applications: Process engineering circuits, heating and cooling systems, water sup-
Voltage V 3∼400 ply and disposal systems etc. in industry and building services.
Speed max. 2,100 (4 poles)

or 4,200 (2 poles)

Reference no. 1149.5

PumpDrive Self-cooling, motor-independent frequency inverter

Max. no. of pumps 6 Design: Self-cooling frequency inverter which allows the motor speed to be varied
FI 1 per pump/motor continuously by means of standard signals and a field bus. Because PumpDrive is
kW 110 self-cooling, it can be mounted on a motor, on the wall or in a cabinet.
Voltage V 3∼380 bis 480 Applications: Cooling circuits, filters, water supply systems, heating, ventilation
and air-conditioning systems, spray irrigation systems, boiler feed systems, steam
generation plants, process engineering circuits, cooling lubricant supply systems,
service water supply systems and other process engineering applications.

Reference no. 4070.5

46
Monitoring and diagnostic systems

Amacontrol Monitoring system for submersible waste water pumps

Max. no. of pumps 1 Design: Monitoring system for submersible waste water pumps with shutdown.
Pumps Amacan
Installation Mounting
plate IP20
Voltage 230 VAC

Reference no. 2316.178

PumpExpert Pump Diagnostic System

Max. no. of pumps 1 Design: Modular diagnostic system with memory.


Pumps See type series booklet
Installation Mounting plate IP20,
steel housing IP54; flameproof hou-
sing for use in potentially explosive
atmospheres EEx d-IIc IP 67
Voltage 24 VDC /
110/230 VAC
Reference no. 4050.5

Switchgears and control systems

Controlmatic E Automatic control unit

Max. no. of pumps 1 Design: Single-pump control system for starting, stopping and monitoring pumps.
kW - Applications: Water supply systems, in combination with pumps like Multi Eco,
Voltage V 1∼230 Multichrom S, Ixo, S 100 B, etc.

Reference no. 5125.1785

Cervomatic EDP Automatic control unit

Max. no. of pumps 1 Design: Single-pump control system for pressure-controlled starting, flow-con-
kW - trolled stopping and monitoring of pumps.
Voltage V 1∼230 / 3∼400 Applications: Water supply systems, in combination with pumps like Multi Eco,
Multichrom S, Ixo, S 100 B, UPA 150 S , etc.

Reference no. 5125.178

47
Switchgears and control systems

UPA Control Control system for submersible borehole pumps

Max. no. of pumps 1 Design: Single-pump control of submersible borehole pumps, submersible motor
kW 3 pumps and dry-installed pumps.
Voltage V 1∼230 / 3∼400 Applications: Water supply systems, in combination with pumps like S 100 B, UPA
150 S, etc.

Reference no. 3465.1

Single-pump control system Control system

Max. no. of pumps 1 Design: Single-pump control system for level- or pressure-controlled starting and
kW 22 stopping of pumps. Variants with bubbler system or float switch, d.o.l. or star-delta
Voltage V 1∼230 / 3∼400 starting.
Applications: Indoor and outdoor installation.

Reference no. 0543.5016

Dual-pump control system Control system

Max. no. of pumps 2 Design: Dual-pump control system for level- or pressure-controlled starting and
kW 22 stopping of pumps. Variants with bubbler system or float switch, d.o.l. or star-delta
Voltage V 1∼230 / 3∼400 starting.
Applications: Indoor and outdoor installation.

Reference no. 0543.5016

48
Fax Order

FAX NO. +49 9241 71-1531

We will be pleased to send you the relevant technical literature of our products. Just copy this blank form, fill in your address
and order details and send it to fax no. +49 9241 71-1531.

You can also simply download the complete literature via the Internet under www.ksb.com/productcatalogue.

Address

Last name First name

Company

Business line Water Waste Water Industry

Energy Building Services Mining

Street, house no.

Postal / zip code Place

Telephone Fax

E-mail

Type series literature order

Reference no. Type series

Reference no. Type series

Reference no. Type series

Reference no. Type series

Reference no. Type series

Reference no. Type series

Yes, I am also interested in the KSB Armaturen und


I have some specific questions and would therefore
Au t o m a t i s i e r u n g s t e c h n i k 2 0 0 5

valve programme. appreciate if a member of your field staff contacted me


Please send me the relevant litera- by phone.
ture. (You can also download this
literature via the Internet.)

Date Signature
Subject to technical modification without prior notice.
KSB. We are where you are.

Your local KSB representative:


bdf
05/05
0506.02/12-10

KSB Aktiengesellschaft • Johann-Klein-Straße 9


67227 Frankenthal (Germany) • www.ksb.com

Vous aimerez peut-être aussi