Confidential BECTA Training Academy

BT02-T1 (Therapeutic Level 1) – SET B

100
(PRE / POST)
THERAPEUTIC

Name : __________________________________________
AP No : __________________________________________
Designation : __________________________________________
Hospital : _________________________________

Choose the correct answer.

1. What is the basic function of an Analgesia Unit inhalation (1m)


a) Analgesia Units used to alleviate pain through the patient skin.
b) Analgesia Units used to alleviate pain through patient inhalation of a gases.
c) Analgesia Units used to alleviate pain through the drug.
d) Analgesia Units doesn’t help patient retain consciousness while pain sensations are
subdued.

2. What is the basic function of an Aspirator? (1m)


a) Aspirator Units used to evacuate gas, fluid, tissue from a body cavity.
b) Aspirator Units help patient to breathe in spontaneously.
c) Aspirator Units used to alleviate pain through patient inhalation of a gas
d) Aspirator Units used to alleviate pain through the patient skin.

3. According to the basic aspirator schematic diagram above, name the part A? (1m)
a) Pressure Gauge
b) Flow Meter
c) Safety Valve
d) Pressure sensor

@COPYRIGHT_APSB-Private and Confidential Page 1


Confidential BECTA Training Academy
BT02-T1 (Therapeutic Level 1) – SET B

4. According to the basic aspirator schematic diagram above, name the part B? (1m)
a) Stopper.
b) Flow meter
c) Cut off Valve.
d) Safety Valve.

5. What is the function of part B that used for the aspirator? (1m)
a) To make sure fluid go in one direction to the pump.
b) To prevent back-up of fluid to either the pump or the patient.
c) To block the flow from the pump to the patient.
d) To prevent high pressure inside the patient tubing.

6. Give the test fixtures for the Aspirator. (1m)


a) Negative Pressure test.
b) Speed Test.
c) Lux test.
d) Vibration test.

7. Give the test fixtures for the Cast Cutter. (1m)


a) Pressure test.
b) Speed Test.
c) Electrical Safety Test.
d) Vibration test.

“Devices used to cut through a cast or bone.”


8. According to the statement above refer to which medical equipment? (1m)
a) Hand Drill
b) Cast Cutter
c) Aspirator
d) Dynamometer

@COPYRIGHT_APSB-Private and Confidential Page 2


Confidential BECTA Training Academy
BT02-T1 (Therapeutic Level 1) – SET B

9. Below is the common spare part for the cast cutter, which on is not the part of cast cutter? (1m)
a) Blade
b) Vacuums motor
c) Bur
d) Battery

10. What are a Dynamometers? (1m)


a) Dynamometers is a device for measuring the intensity of light,
b) Dynamometers is a device for measuring the degree of force used in the contraction of a
group of muscles,
c) Dynamometers is a device for measuring the volume of fluid.
d) Dynamometers is a device for measuring the current of contraction of a group of muscles.

11. Give measurement unit for Dynamometers? (1m)


a) Litre
b) Meter
c) Lux
d) Kg/pounds

12. What are Infusion devices used for? Choose the best answer. (1m)
a) To infuse liquid to patient.
b) To infuse an accurate amount with controlled flow, prescribe of medication, blood or nutrient.
c) To infuse an accurate amount with controlled flow, prescribe of medication, blood, nutrient,
drug through patient intravenous.
d) To infuse an accurate amount and controlled flow prescribe of medication, blood, nutrient,
drug through patient intravenous with a few safety alarm systems.

13. What are the different between general purpose infusion pump and syringe pump? (1m)
I. Infusion pump using peristatic movement for infuse medication fluid.
II. Syringe pump using driven motor to infuse medication fluid or drug.
III. Infusion pump giving medication fluid in large amount.
IV. Syringe pump giving medication drug in large amount.

a) I, II & III c) I, III & IV


b) II, III & IV d) All above

14. Trainers, auditory is use to (1m)


a) Stimulate hearing system.
b) To train person with auditory processing difficulties.
c) To diagnose eardrum disease.
d) To irrigate vaccine/medicine through ear canal.

@COPYRIGHT_APSB-Private and Confidential Page 3


Confidential BECTA Training Academy
BT02-T1 (Therapeutic Level 1) – SET B

15. Why patient need to use ripple mattress /pressure pad in hospital? (1m)
a) To irrigate vaccine/medicine through skin patient
b) To train person with bed processing difficulties.
c) To make sure patient more comfortable.
d) To prevent patient from bed sores or pressure sores.

16. Nebulizers use _______, ________, or _________ power to break up solutions and suspensions
into small aerosol droplets. (1m)

I. Oxygen
II. Compressed Air
III. Ultrasonic
IV. Hydraulic

a) I, II & III c) I, III & IV


b) II, III & IV d) All above

17. What is the test equipment used to measure breast pump? (1m)

I. Electrical Safety Analyzer


II. Vacuum gauge
III. Tachometer
IV. Digital force gauge

a) I and II c) I, II and III


b) I and IV d) All above

18. What kind of device used to measure intraocular pressure IOP? (1m)

a) Manometer
b) Lux meter
c) Tachometer
d) Tonometer

19. Give normal range value intraocular pressure IOP? (1m)

a) 5mmHg - 10mmHg
b) 10mmHg - 20mmHg
c) 20mmHg - 30mmHg
d) 30mmHg - 40mmHg

@COPYRIGHT_APSB-Private and Confidential Page 4


Confidential BECTA Training Academy
BT02-T1 (Therapeutic Level 1) – SET B

20. According to the basic heating unit schematic diagram below, name the part A? (1m)

a) Heating element
b) Pilot light
c) Thermostat
d) Day light

@COPYRIGHT_APSB-Private and Confidential Page 5