Vous êtes sur la page 1sur 8

C U A D R O D E C A R G A S (380/220 V)

SERVICIO PARTICULAR Y CARGAS ESPECIALES ALUMBRADO PUBLICO SUB-TOTAL POT. TRANSF.


SED CIRCUITO Nº LOTES S.P. C.E. P.T. I Nº P.AP. I P. TOTAL
KW
TOTAL KW (KW) (KW) (A) LAMPARAS (KW) (A) (KW)
C-1 42 12.60 0.00 12.60 21.27 10 0.600 3.03 13.20
C-2 46 13.80 5.00 18.80 31.74 11 0.660 3.33 19.46
C-3 39 11.70 0.00 11.70 19.75 9 0.540 2.73 12.24
SED N°01 12.24
C-4 12 3.60 3.60 6.08 4 0.240 1.21 3.84
C-5 3 0.90 2.775 3.68 6.20 3 0.180 0.91 3.86
TOTAL 142 43 8 50 85 37 2 PERDIDAS 10%SP

SUB TOTAL 1.17


PROYECCION kW, 20 AÑOS
con r=1,2% 13.41
POTENCIA DE TRAFO KVA 17.02
POTENCIA NOMINAL KVA 18.91
50
PARAMETROS Y FACTORES DE CAIDA DE TENSION DE LOS CABLES AUTOPORTANTES CAAI (ND)
CONDUCTOR DE FASE 3Φ 380 V CONDUCTOR ADICIONAL (ALUMBRADO) 1Φ 220 V

RESISTENCIA RESISTENCIA
FACTOR K CAPACIDAD FACTOR K CAPACIDAD
TIPO DE CONDUCTOR OHMICA REACTANCIA OHMICA Rcc 20 °C REACTANCIA
(ohms/Km) DE CAIDA DE DE (ohms/Km) DE CAIDA DE DE
INDUCTIVA INDUCTIVA
TENSION CORRIENTE TENSION CORRIENTE
(ohms/Km) (ohms/Km)
(ohms/Km) (A) (ohms/Km) (A)
A 20° C A 40° C A 20° C A 40° C

1 CAAI 3X16 + 1X16 + ND 25 mm² 1.910 2.048 0.1095 3.2752 89 1.910 2.048 0.1095 3.7819 89

Sistema: 380/220
CosΦ
(SP) 0.9
SenoΦ
0.436
(SP)

CosΦ
(AP) 0.9
SenoΦ
0.436
(AP)
PROYECTO RED W/Lote
: SECUNDARIA : 600
LOCALIDAD LOS
: ARENALES FS (SP) : 0.5
PROVINCIA
: VIRÚ FS (AP) : 0.90
LA LIBERTAD Cos f
DEPARTAMENTO : (SP) : 0.9
Cos f
(AP) : 0.9
SE N° : SISTEMA : Pot.Nominal(KVA)
1 3F:380/220 50
V(SP): 380 V 3Φ
V(AP): 220 V 1Φ

PPL 60 W
CIRCUITO N° C-1
SERIVICIO PARTICULAR Y CARGAS ESPECIALES
POT.
∑ ∆V
Nodo Tipo Long. N° de S.P Pot. C.E. Pot. Total I. Nodo K3Φ ∆V % ∑ ∆V Pp
N° Conductor (m) Lotes (kW) (KW) (KW) (A) (Ohm/Km) (V) (V) - (W)
1 CAAI 3x16+16+ ND25 mm2 40.00 4 1.2 0 12.6 21.27 3.2752 2.787 2.787 0.733 111.18
2 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 11.4 19.25 3.2752 1.261 1.261 0.332 45.53
3 CAAI 3x16+16+ ND25 mm2 32.00 5 1.5 0 10.2 17.22 3.2752 1.805 1.805 0.475 58.30
4 CAAI 3x16+16+ ND25 mm2 35.00 5 1.5 0 8.7 14.69 3.2752 1.684 1.684 0.443 46.40
5 CAAI 3x16+16+ ND25 mm2 30.00 4 1.2 0 7.2 12.15 3.2752 1.194 1.194 0.314 27.21
6 CAAI 3x16+16+ ND25 mm2 20 4 1.2 0 6.0 10.13 3.2752 0.664 0.664 0.175 12.61
7 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 4.8 8.1 3.2752 0.531 0.531 0.140 8.06
8 CAAI 3x16+16+ ND25 mm2 15.00 4 1.2 0 3.6 6.08 3.2752 0.299 0.299 0.079 3.41
9 CAAI 3x16+16+ ND25 mm2 15.00 4 1.2 0 2.4 4.05 3.2752 0.199 0.199 0.052 1.51
10 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 1.2 2.03 3.2752 0.133 0.133 0.035 0.51
ALUMBRADO PÚBLICO
N° Luminarias Pot. Nodo Pot. TOtal K1Φ I (AP) ∆V ∑ ∆V % ∆V Pp
(u) (KW) (KW) (Ohm/Km) (A) (V) (V) - (W)
1 0.06 0.60 3.7819 3.03 0.460 0.460 0.210 1.50
1 0.06 0.54 3.7819 2.73 0.210 0.210 0.100 0.61
1 0.06 0.48 3.7819 2.42 0.290 0.290 0.130 0.77
1 0.06 0.42 3.7819 2.12 0.280 0.280 0.130 0.64
1 0.06 0.36 3.7819 1.82 0.210 0.210 0.100 0.41
1 0.06 0.30 3.7819 1.52 0.110 0.110 0.050 0.19
1 0.06 0.24 3.7819 1.21 0.090 0.090 0.040 0.12
1 0.06 0.18 3.7819 0.91 0.050 0.050 0.020 0.05
1 0.06 0.12 3.7819 0.61 0.030 0.030 0.010 0.02
1 0.06 0.06 3.7819 0.30 0.020 0.020 0.010 0.01
CIRCUITO N° C-2
SERIVICIO PARTICULAR Y CARGAS ESPECIALES
POT.
∑ ∆V
Nodo Tipo Long. N° de S.P Pot. C.E. Pot. Total I. Nodo K3Φ ∆V % ∑ ∆V Pp
N° Conductor (m) Lotes (kW) (KW) (KW) (A) (Ohm/Km) (V) (V) - (W)
1 CAAI 3x16+16+ ND25 mm2 25.00 5 1.5 0 13.8 23.3 3.2752 1.908 1.908 0.502 83.39
2 CAAI 3x16+16+ ND25 mm2 15.00 5 1.5 0 12.3 20.76 3.2752 1.020 1.020 0.268 39.72
3 CAAI 3x16+16+ ND25 mm2 25.00 5 1.5 0 10.8 18.23 3.2752 1.493 1.493 0.393 51.05
4 CAAI 3x16+16+ ND25 mm2 15.00 5 1.5 0 9.3 15.7 3.2752 0.771 0.771 0.203 22.72
5 CAAI 3x16+16+ ND25 mm2 25.00 3 0.9 0 7.8 13.17 3.2752 1.078 1.078 0.284 26.64
6 CAAI 3x16+16+ ND25 mm2 25.00 3 0.9 0 6.9 11.65 3.2752 0.954 0.954 0.251 20.85
7 CAAI 3x16+16+ ND25 mm2 25.00 4 1.2 0 6.0 10.13 3.2752 0.829 0.829 0.218 15.76
8 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 4.8 8.1 3.2752 0.531 0.531 0.140 8.06
9 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 3.6 6.08 3.2752 0.398 0.398 0.105 4.54
10 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 2.4 4.05 3.2752 0.265 0.265 0.070 2.02
11 CAAI 3x16+16+ ND25 mm2 15.00 4 1.2 0 1.2 2.03 3.2752 0.100 0.100 0.026 0.38

ALUMBRADO PÚBLICO
N° Luminarias Pot. Nodo Pot. TOtal K1Φ I (AP) ∆V ∑ ∆V % ∆V Pp
(u) (KW) (KW) (Ohm/Km) (A) (V) (V) - (W)
1 0.06 0.66 3.7819 3.33 0.310 0.310 0.140 1.14
1 0.06 0.60 3.7819 3.03 0.170 0.170 0.080 0.56
1 0.06 0.54 3.7819 2.73 0.260 0.260 0.120 0.76
1 0.06 0.48 3.7819 2.42 0.140 0.140 0.060 0.36
1 0.06 0.42 3.7819 2.12 0.200 0.200 0.090 0.46
1 0.06 0.36 3.7819 1.82 0.170 0.170 0.080 0.34
1 0.06 0.30 3.7819 1.52 0.140 0.140 0.060 0.24
1 0.06 0.24 3.7819 1.21 0.090 0.090 0.040 0.12
1 0.06 0.18 3.7819 0.91 0.070 0.070 0.030 0.07
1 0.06 0.12 3.7819 0.61 0.050 0.050 0.020 0.03
1 0.06 0.06 3.7819 0.30 0.020 0.020 0.010 0.01
CIRCUITO N° C-3
SERIVICIO PARTICULAR Y CARGAS ESPECIALES
POT.
∑ ∆V
Nodo Tipo Long. N° de S.P Pot. C.E. Pot. Total I. Nodo K3Φ ∆V % ∑ ∆V Pp
N° Conductor (m) Lotes (kW) (KW) (KW) (A) (Ohm/Km) (V) (V) - (W)
1 CAAI 3x16+16+ ND25 mm2 25.00 4 1.2 0 11.7 19.75 3.2752 1.617 1.617 0.426 59.91
2 CAAI 3x16+16+ ND25 mm2 15.00 4 1.2 0 10.5 17.73 3.2752 0.871 0.871 0.229 28.97
3 CAAI 3x16+16+ ND25 mm2 25.00 5 1.5 0 9.3 15.7 3.2752 1.286 1.286 0.338 37.86
4 CAAI 3x16+16+ ND25 mm2 15.00 5 1.5 0 7.8 13.17 3.2752 0.647 0.647 0.170 15.99
5 CAAI 3x16+16+ ND25 mm2 25.00 5 1.5 0 6.3 10.64 3.2752 0.871 0.871 0.229 17.39
6 CAAI 3x16+16+ ND25 mm2 25.00 4 1.2 0 4.8 8.1 3.2752 0.663 0.663 0.174 10.08
7 CAAI 3x16+16+ ND25 mm2 25.00 4 1.2 0 3.6 6.08 3.2752 0.498 0.498 0.131 5.68
8 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 2.4 4.05 3.2752 0.265 0.265 0.070 2.02
9 CAAI 3x16+16+ ND25 mm2 20.00 4 1.2 0 1.2 2.03 3.2752 0.133 0.133 0.035 0.51

ALUMBRADO PÚBLICO
N° Luminarias Pot. Nodo Pot. TOtal K1Φ I (AP) ∆V ∑ ∆V % ∆V Pp
(u) (KW) (KW) (Ohm/Km) (A) (V) (V) - (W)
1 0.06 0.54 3.7819 2.73 0.260 0.260 0.120 0.76
1 0.06 0.48 3.7819 2.42 0.140 0.140 0.060 0.36
1 0.06 0.42 3.7819 2.12 0.200 0.200 0.090 0.46
1 0.06 0.36 3.7819 1.82 0.100 0.100 0.050 0.20
1 0.06 0.30 3.7819 1.52 0.140 0.140 0.060 0.24
1 0.06 0.24 3.7819 1.21 0.110 0.110 0.050 0.15
1 0.06 0.18 3.7819 0.91 0.090 0.090 0.040 0.08
1 0.06 0.12 3.7819 0.61 0.050 0.050 0.020 0.03
1 0.06 0.06 3.7819 0.30 0.020 0.020 0.010 0.01
CIRCUITO N° C-4
SERIVICIO PARTICULAR Y CARGAS ESPECIALES
POT.
∑ ∆V
Nodo Tipo Long. N° de S.P Pot. C.E. Pot. Total I. Nodo K3Φ ∆V % ∑ ∆V Pp
N° Conductor (m) Lotes (kW) (KW) (KW) (A) (Ohm/Km) (V) (V) - (W)
1 CAAI 3x16+16+ ND25 mm2 25.00 4 1.2 0 3.3 5.57 3.2752 0.456 0.456 0.120 4.77
2 CAAI 3x16+16+ ND25 mm2 15.00 4 1.2 0 2.1 3.55 3.2752 0.174 0.174 0.046 1.16
3 CAAI 3x16+16+ ND25 mm2 15.00 3 0.9 0 0.9 1.52 3.2752 0.075 0.075 0.020 0.21

ALUMBRADO PÚBLICO
N° Luminarias Pot. Nodo Pot. TOtal K1Φ I (AP) ∆V ∑ ∆V % ∆V Pp
(u) (KW) (KW) (Ohm/Km) (A) (V) (V) - (W)
1 0.06 0.18 3.7819 0.91 0.090 0.090 0.040 0.08
1 0.06 0.12 3.7819 0.61 0.030 0.030 0.010 0.02
1 0.06 0.06 3.7819 0.30 0.020 0.020 0.010 0.01

Vous aimerez peut-être aussi