Vous êtes sur la page 1sur 41

June 9, 2016

Precision Wall Systems


10980 Alder Circle
Dallas, TX 75238

Attn: Stephen Loyd

RE: Zara Broadway Plaza


Walnut Creek, CA

Letter of Compliance:

Per your request, we have reviewed the referenced project’s design parameters for the 30 mm
Caliza Limra Limestone units. This structural review was performed to determine the integrity of the
specified stone material and the specific requirements and/or deviations to the standard installation
requirements for the Gridworx Aluminum Anchoring System.

Design Wind and Seismic Pressures have been evaluated and determined in accordance with the
2013 California Building Code and ASCE 7-10. Interpretation of the Building Codes for the project
location, the maximum building height, and site specific parameters for Components and Cladding,
with tributary areas of 10 square feet, yields critical design pressures as follows:

Typical Wind Zone regions as +14.73 psf / -15.97 psf


Corner Wind Zone regions as +14.73 psf / -19.72 psf

Seismic on Body Components as +/- 10.575 psf


Seismic on Connection Components as +/- 33.047 psf

Specific site parameters for the project have been interpreted as:

Basic Wind Speed = 110 mph


Mean Roof Height = 45’-0”
Exposure = B
Category = II
Importance Factor, IW = 1.0
Importance Factor, IE = 1.0

Specific Requirements and Materials identified for compliance are as follows:

Stone Material = Caliza Limra


Limestone Min MOD Rupture = NA
Min FLEX Strength = 1000 psi
Density = 152 pcf
Weight (1.181” stone) = 16.54 psf

Nominal thickness = 1.181” Tolerance - (+ / - 1/8”)


Gage from face = 0.500” Tolerance - (+ / - 1/16”)
Kerf width = 0.188” Tolerance - (+ / - 1/16”)
Kerf depth = 0.500” Tolerance - (+ 1/8, - 1/16”)

5118 Burnet Rd. l Suite E l Austin, TX l 78756 l 512.270.6869


Precision Wall Systems – Components Provided:

Stone Strength = Meets Safety Factor > 8.0 AGAINST BREAKAGE


Meets Safety Factor > 12.0 AGAINST KERF BREAK

Gridworx Extrusions = 6005 – T5 aluminum continuous provided in 12’-0” lengths


Top of stone L Bracket Anchors, 6” long
(1) bracket required per foot of panel width
Extended Interm. T at bottom of 5 5/8” thick cornice stone
Extended Top and Starter J at some locations

“Z” Channels = “Z” vertical furring (1”x1”x1”), Thickness = 0.090”


6005-T5 Aluminum Install at 16” o.c. horizontally

Discrete Clips = Discrete Clip Thickness = 1/8”, 4” long


6005-T5 Aluminum Install at 24” o.c. vertical spacing

Extrusion Fasteners = Elco Dril-Flex #12-14


to “Z” Channel/Studs 1 1/2” long at “Z” Channel, 2” long at stud framing
(SAE J 429 / Grade 5 with Stalgard Coating)

Shim Stack = Full-bearing Hi-Impact resistant plastic shims


Minimum 1/16” Bond Breaker at dissimilar metals
Maximum allowable shim stack = 5/8”

“Z” Channel Fasteners = Elco Dril-Flex #12-14 x 7/8” long


to Discrete Clip (SAE J 429 / Grade 5 with Stalgard Coating)
(2) per Discrete Clip

Discrete Clip Fasteners = Elco Dril-Flex #12-14 x 2” long


to Studs (SAE J 429 / Grade 5 with Stalgard Coating)
(2) per Discrete Clip

Gridworx Fork Supports = Standard Fork Support


6005 – T5 aluminum
Continuous at fascia panels, min. 3” long at soffit panels

T-31 Anchors = 1 1/4” Stone Anchors at Fork Support


Install @ 16” o.c. horizontally at cornice fascia panels
Install for soffit intermediate support @ 16” o.c. spacing

Aluminum L Bracket = 2” x 2” x 0.09” Aluminum Angle, 2” long


at Soffit 6005 – T5 aluminum
Install at discrete clip locations at soffit conditions
w/ (2) Elco Dril-Flex #12-14 x 7/8” long

Silicone = Low modulus silicone applied at Gridworx L Brackets.

Recommended = Dow Corning 790 Silicone or equal and open cell


Joint Sealant backer rod.

Cantilevered extrusions bypassing the substrate or attachment are acceptable for distances
equal to half the typical supported span. The stone panels are to be supported for wind and
dead load at each course and not to be hard stacked to a specific level or starter extrusion.
10980 Alder Circle
Dallas, TX 75238
(214) 774-4502

ZARA BROADWAY PLAZA


WALNUT CREEK, CA

SUPPLEMENTARY CALCULATIONS
1ST SUBMITTAL

June 9, 2016

5118 Burnet Rd. l Suite E l Austin, TX l 78756 l 512.270.6869


ZARA Broadway Plaza
Structural Calculations
Walnut Creek, CA
Prepared By: SJM

TABLE OF CONTENTS

Item Description Page #

1 ASCE 7-10 Windload Analysis 3

2 ASCE 7-10 Seismic Analysis 4

3 Stone Analysis 6

4 Typical Gridworx System 11

5 ASHRAE System 22

6 Miscellaneous Reference 32

Applicable Building Code: 2013 California Building Code / Chapters 16, 19, 20, 24
ASCE 7- 10 Minimum Design Loads for Buildings and Other
Structures

Computer Programs: MCAL Software; Cbeam 2005, Aprop 2.2, IBC-ASCE 7 3.0
Parametric Technology Corporation; MathCAD 14
Bentley Systems Inc.; Staad Pro 2007
Architectural Wall Systems Inc.; Analysis 2010
Standards Design Group Inc; Window Glass Design

ZARA - PRECISION JUN 09 2016 2


WIND LOADING (ASCE 7-10) - COMPONENTS AND CLADDING DESIGN METHOD
DESIGN CRITERIA
Basic Wind Speed (V) 110 mph Enclosure Classification Enclosed
Exposure Category B Topographic Factor (Kzt) 1.00

Risk Category II Corner Zone Distance 8.5 ft


Height Above Ground
45 ft
Level, z
Building Least Width 85 ft

WIND LOAD REQUIREMENTS


Directionality Factor (Kd) 0.85 (+) WL (-) WL
Internal Pressure
Hurricane Prone Region? No Coefficient (GCpi) 0.18 -0.18

Wind Borne Debris


No
Region?
Velocity Pressure
Exposure Coefficient (Kz) 0.79

Nominal Height of
Atmospheric boundary 1200 ft
layer (zg)

Velocity Pressure (qh) 20.80 psf (qh = 0.00256 Kz Kd Kzt V2)

WIND PRESSURE CALCULATION – LRFD


Zone 4: Typical Zone 5: Corner
Area (SF) GCp(+) PSF GCp(-) PSF GCp(+) PSF GCp(-) PSF
10 1.00 24.54 -1.10 -26.62 1.00 24.54 -1.40 -32.86
20 0.95 23.50 -1.05 -25.58 0.95 23.50 -1.29 -30.58
50 0.88 22.05 -0.98 -24.13 0.88 22.05 -1.15 -27.66
100 0.82 20.80 -0.92 -22.88 0.82 20.80 -1.05 -25.58

WIND PRESSURE CALCULATION – ASD (0.6 FACTOR APPLIED)


Zone 4: Typical Zone 5: Corner
Area (SF) GCp(+) PSF GCp(-) PSF GCp(+) PSF GCp(-) PSF
10 1.00 14.73 -1.10 -15.97 1.00 14.73 -1.40 -19.72
20 0.95 14.10 -1.05 -15.35 0.95 14.10 -1.29 -18.35
50 0.88 13.23 -0.98 -14.48 0.88 13.23 -1.15 -16.60
100 0.82 12.48 -0.92 -13.73 0.82 12.48 -1.05 -15.35

FILE: AWS WL Spreadsheet (ASCE 7-10).xls


ZARA - PRECISION JUN 09 2016 3
SEISMIC ANALYSIS PER ASCE 7-10

Each element or component and its connections to the structure shall be designed to resist a total lateral
seismic force, Fp, as provided by the following ASCE 7-10 equation (13.3-1 pg. 113):

0.4 ⋅ ap ⋅ Sds ⋅ WE ⎛ z⎞
Fp ≔ ―――――⋅ ⎜1 + 2 ⋅ ― ⎟
⎛ Rp ⎞ ⎝ h⎠
⎜―― ⎟
⎝ IE ⎠

Coefficient Values for Input:

Sds ≔ 1.332 (Structural Notes Sheet S-000.00)

IE ≔ 1.0 (ASCE 7-10 - Section 13.1.3)

h ≔ 45 ⋅ ft (Structure Roof Height)

z ≔ 45 ⋅ ft (Worst Case Height of Component Attachment)

WE ≔ 16.54 ⋅ psf (Weight of 1.181" thick Caliza Limra Limestone + 1/8" Tolerance)

Due to the continuity of the curtainwall system and a series of lateral load resisting anchors, applied seismic loading
can be modified as a uniformly distributed load proportionate to the mass distribution over the height.
Therefore, the computed magnitude of the seismic load can be compared to the windload pressure to determine the
governing normal design load for anchoring components. In-plane requirements must be independently investigated
utilizing the computed seismic requirements and continuity developed by the applicable element.

Per Section 13.4 Nonstructural Component Anchorage:

1. Bodies of the connection shall be designed for the force determined by Equation (13.3-1) where:

Rp_Body ≔ 2.5 and ap_Body ≔ 1.0 (Values from Table 13.5-1 pg. 117)

0.4 ⋅ ap_Body ⋅ Sds ⋅ WE ⎛ z⎞


Therefore, Fp_Body ≔ ――――――― ⋅ ⎜1 + 2 ⋅ ―⎟ Fp_Body = 10.575 psf
Rp_Body ⎝ h⎠
―――
IE

2. All Fasteners in the connecting system. such as bolts, inserts, weld and dowels, shall be designed for
the forces determined by Equation (13.3-1) where:
Rp_Connection ≔ 1.0 and ap_Connection ≔ 1.25 (Values from Table 13.5-1 pg. 117)

0.4 ⋅ ap_Connection ⋅ Sds ⋅ WE ⎛ z⎞


Therefore, Fp_Connection ≔ ――――――――⋅ ⎜1 + 2 ⋅ ― ⎟ Fp_Connection = 33.047 psf
Rp_Connection ⎝ h⎠
――――
IE

Note: The above values for Fp are derived using a factored load method. For use with allowable stress design
methods (ASD), these values can be multiplied by the seismic load factor of 0.7 per ASCE 7-10 Section 2.4 pg. 8.

BC-ASCE7-2010-Seismic.mcdx
-------- ---------------------------------------------------------------------------------------
ZARA - PRECISION JUN 09 2016 4
SEISMIC ANALYSIS PER ASCE 7-10

Each element or component and its connections to the structure shall be designed to resist a total lateral
seismic force, Fp, as provided by the following ASCE 7-10 equation (13.3-1 pg. 113):

0.4 ⋅ ap ⋅ Sds ⋅ WE ⎛ z⎞
Fp ≔ ―――――⋅ ⎜1 + 2 ⋅ ― ⎟
⎛ Rp ⎞ ⎝ h⎠
⎜―― ⎟
⎝ IE ⎠

Coefficient Values for Input:

Sds ≔ 1.332 (Structural Notes Sheet S-000.00)

IE ≔ 1.0 (ASCE 7-10 - Section 13.1.3)

h ≔ 45 ⋅ ft (Structure Roof Height)

z ≔ 45 ⋅ ft (Worst Case Height of Component Attachment)

WE ≔ 72.83 ⋅ psf (Weight of 5.625" thick Caliza Limra Limestone + 1/8" Tolerance)

Due to the continuity of the curtainwall system and a series of lateral load resisting anchors, applied seismic loading
can be modified as a uniformly distributed load proportionate to the mass distribution over the height.
Therefore, the computed magnitude of the seismic load can be compared to the windload pressure to determine the
governing normal design load for anchoring components. In-plane requirements must be independently investigated
utilizing the computed seismic requirements and continuity developed by the applicable element.

Per Section 13.4 Nonstructural Component Anchorage:

1. Bodies of the connection shall be designed for the force determined by Equation (13.3-1) where:

Rp_Body ≔ 2.5 and ap_Body ≔ 1.0 (Values from Table 13.5-1 pg. 117)

0.4 ⋅ ap_Body ⋅ Sds ⋅ WE ⎛ z⎞


Therefore, Fp_Body ≔ ――――――― ⋅ ⎜1 + 2 ⋅ ―⎟ Fp_Body = 46.565 psf
Rp_Body ⎝ h⎠
―――
IE

2. All Fasteners in the connecting system. such as bolts, inserts, weld and dowels, shall be designed for
the forces determined by Equation (13.3-1) where:
Rp_Connection ≔ 1.0 and ap_Connection ≔ 1.25 (Values from Table 13.5-1 pg. 117)

0.4 ⋅ ap_Connection ⋅ Sds ⋅ WE ⎛ z⎞


Therefore, Fp_Connection ≔ ――――――――⋅ ⎜1 + 2 ⋅ ― ⎟ Fp_Connection = 145.514 psf
Rp_Connection ⎝ h⎠
――――
IE

Note: The above values for Fp are derived using a factored load method. For use with allowable stress design
methods (ASD), these values can be multiplied by the seismic load factor of 0.7 per ASCE 7-10 Section 2.4 pg. 8.

BC-ASCE7-2010-Seismic - Cornice.mcdx
-------- ---------------------------------------------------------------------------------------
ZARA - PRECISION JUN 09 2016 5
STONE ANALYSIS

ZARA - PRECISION JUN 09 2016 6


ZARA - PRECISION JUN 09 2016 7
DESIGN OF CALIZA LIMRA UNIT – FASCIA
Design Data: Material Type: Limestone Nominal Dimensions / Tolerance:
ASTM C99 MOR = NA (psi) Nominal Thickness, t = 1.181 (in)
ASTM C880 FLEX = 1000 (psi) Tolerance, e1 (thickness) = 0.125 (in)
ASTM C97 Density = 152 (pcf) Kerf Gage, kg = 0.5 (in)
Kerf Thickness, kt = 0.1875 (in)
Safety Factor: Span = 8 Kerf Depth, kd = 0.625 (in)
Anchor = 12 Tolerance, e2 (kerf) = 0.0625 (in)
Kerf Engagement, ke = 0.25 (in)
Kerf Length / Clip, l = 6 (in) (Standard)

Design Loads: (+WL) = 14.43 (psf) Seis*0.7 (Stone) = 7.40 (psf)


(-WL) = 19.72 (psf) Seis*0.7 (Kerf) = 23.13 (psf)

MATERIAL SPECIFICATIONS
Average Rupture Strength (MOR) = NA psi
Average Flexural Strength (FLEX) = 1,000 psi
Allowable Span Stress, Fbspan (Min AVG / S.F.) = 125 psi
Allowable Anchor Stress, Fbanchor (Min AVG / S.F.) = 83 psi
A(G) NOM. THICKNESS MIN. THICKNESS KERF KERF
PANEL PANEL GROSS PANEL STRENGTH STRENGTH CAPACITY CAPACITY
WIDTH, W HEIGHT, H AREA WEIGHT RATIO RATIO (FRONT) (BACK)
(in.) (in.) (ft.2) (lb.) (fbn / Fbspan) (fbmin / Fbspan) (fbKf / Fbanchor) (fbKb / Fbanchor)
60.000 24.000 10.000 165.427 0.339 0.424 0.272 0.556 Uniform Load
60.000 22.000 9.167 151.641 0.285 0.357 0.249 0.510

60.000 24.000 10.000 165.427 0.339 0.424 0.420 0.859 Point Load
60.000 22.000 9.167 151.641 0.285 0.357 0.385 0.787

MINIMUM THICKNESS CHECK


PANEL PANEL MIN. THICKNESS
WIDTH, W HEIGHT, H REQUIRED CONTROLLING
(in.) (in.) (in.) FACTOR
60.000 24.000 0.813 Nom. Thickness
60.000 22.000 0.756 Nom. Thickness

NOTES:
ALLOWABLE STRESSES AND DESIGN PROCEDURES FOR STONE STRENGTH USE AVERAGE TEST VALUES PER ASTM C99 "MODULUS OF RUPTURE"
AND ASTM C880 "FLEXURAL STRENGTH - MODIFIED" COMPARED TO SPECIFIED AND /OR INDUSTRY STANDARD SAFETY FACTORS.

DESIGN THICKNESS = "Nominal - Tolerance @ Thickness (e1)".


KERF GAGE = "kg" is defined as the nominal dimension for kerf location off stone face.
KERF THICKNESS = "kt" is defined as the dimension for kerf fabrication width.
KERF DEPTH = "kd" is defined as the dimension for kerf fabrication depth into edge of stone.
KERF ENGAGEMENT = "ke" is defined as the depth of kerf clip into the kerf depth.
KERF TOLERANCE = "e2" is defined as the dimension tolerance for kerf location off stone face.
KEFT CLIP LENGTH = "l" is the defined dimension of the clip at top of stone at 1/4 points of panel.

ALL DESIGN STRESSES AND DESIGN VALUES ACCOUNT FOR NOMINAL DIMENSIONS AND THE APPROPRIATE TOLERANCES.
ZARA - PRECISION JUN 09 2016 8
DESIGN OF CALIZA LIMRA UNIT – CORNICE
Design Data: Material Type: Limestone Nominal Dimensions / Tolerance:
ASTM C99 MOR = NA (psi) Nominal Thickness, t = 5.625 (in)
ASTM C880 FLEX = 1000 (psi) Tolerance, e1 (thickness) = 0.125 (in)
ASTM C97 Density = 152 (pcf) Kerf Gage, kg = 4.8125 (in)
Kerf Thickness, kt = 0.1875 (in)
Safety Factor: Span = 8 Kerf Depth, kd = 0.625 (in)
Anchor = 12 Tolerance, e2 (kerf) = 0.0625 (in)
Kerf Engagement, ke = 0.25 (in)
Kerf Length / Clip, l = 6 (in) (Standard)

Design Loads: (+WL) = 14.43 (psf) Seis*0.7 (Stone) = 32.60 (psf)


(-WL) = 19.72 (psf) Seis*0.7 (Kerf) = 101.86 (psf)

MATERIAL SPECIFICATIONS
Average Rupture Strength (MOR) = NA psi
Average Flexural Strength (FLEX) = 1,000 psi
Allowable Span Stress, Fbspan (Min AVG / S.F.) = 125 psi
Allowable Anchor Stress, Fbanchor (Min AVG / S.F.) = 83 psi
A(G) NOM. THICKNESS MIN. THICKNESS KERF KERF
PANEL PANEL GROSS PANEL STRENGTH STRENGTH CAPACITY CAPACITY
WIDTH, W HEIGHT, H AREA WEIGHT RATIO RATIO (FRONT) (BACK)
(in.) (in.) (ft.2) (lb.) (fbn / Fbspan) (fbmin / Fbspan) (fbKf / Fbanchor) (fbKb / Fbanchor)
60.000 9.000 3.750 273.125 0.003 0.004 0.004 0.449 Uniform Load

60.000 9.000 3.750 273.125 0.003 0.004 0.006 0.694 Point Load

MINIMUM THICKNESS CHECK


PANEL PANEL MIN. THICKNESS
WIDTH, W HEIGHT, H REQUIRED CONTROLLING
(in.) (in.) (in.) FACTOR
60.000 9.000 0.899 Kerf-Back

NOTES:
ALLOWABLE STRESSES AND DESIGN PROCEDURES FOR STONE STRENGTH USE AVERAGE TEST VALUES PER ASTM C99 "MODULUS OF RUPTURE"
AND ASTM C880 "FLEXURAL STRENGTH - MODIFIED" COMPARED TO SPECIFIED AND /OR INDUSTRY STANDARD SAFETY FACTORS.

DESIGN THICKNESS = "Nominal - Tolerance @ Thickness (e1)".


KERF GAGE = "kg" is defined as the nominal dimension for kerf location off stone face.
KERF THICKNESS = "kt" is defined as the dimension for kerf fabrication width.
KERF DEPTH = "kd" is defined as the dimension for kerf fabrication depth into edge of stone.
KERF ENGAGEMENT = "ke" is defined as the depth of kerf clip into the kerf depth.
KERF TOLERANCE = "e2" is defined as the dimension tolerance for kerf location off stone face.
KEFT CLIP LENGTH = "l" is the defined dimension of the clip at top of stone at 1/4 points of panel.

ALL DESIGN STRESSES AND DESIGN VALUES ACCOUNT FOR NOMINAL DIMENSIONS AND THE APPROPRIATE TOLERANCES.
ZARA - PRECISION JUN 09 2016 9
DESIGN OF CALIZA LIMRA UNIT – SOFFIT
Design Data: Material Type: Limestone Nominal Dimensions / Tolerance:
ASTM C99 MOR = NA (psi) Nominal Thickness, t = 1.181 (in)
ASTM C880 FLEX = 1000 (psi) Tolerance, e1 (thickness) = 0.125 (in)
ASTM C97 Density = 152 (pcf) Kerf Gage, kg = 0.5 (in)
Kerf Thickness, kt = 0.1875 (in)
Safety Factor: Span = 8 Kerf Depth, kd = 0.625 (in)
Anchor = 12 Tolerance, e2 (kerf) = 0.0625 (in)
Kerf Engagement, ke = 0.25 (in)
Kerf Length / Clip, l = 6 (in) (Standard)

Design Loads: (+WL) = 14.43 (psf) Seis*0.2+DL (Stone) = 18.66 (psf)


(-WL+DL) = 36.26 (psf) Seis*0.2+DL (Kerf) = 23.15 (psf)

MATERIAL SPECIFICATIONS
Average Rupture Strength (MOR) = NA psi
Average Flexural Strength (FLEX) = 1,000 psi
Allowable Span Stress, Fbspan (Min AVG / S.F.) = 125 psi
Allowable Anchor Stress, Fbanchor (Min AVG / S.F.) = 83 psi
A(G) NOM. THICKNESS MIN. THICKNESS KERF KERF
PANEL PANEL GROSS PANEL STRENGTH STRENGTH CAPACITY CAPACITY
WIDTH, W HEIGHT, H AREA WEIGHT RATIO RATIO (FRONT) (BACK)
(in.) (in.) (ft.2) (lb.) (fbn / Fbspan) (fbmin / Fbspan) (fbKf / Fbanchor) (fbKb / Fbanchor)
8.000 16.000 0.889 14.705 0.277 0.347 0.181 0.581 Uniform Load

8.000 16.000 0.889 14.705 0.277 0.347 0.187 0.598 Point Load

MINIMUM THICKNESS CHECK


PANEL PANEL MIN. THICKNESS
WIDTH, W HEIGHT, H REQUIRED CONTROLLING
(in.) (in.) (in.) FACTOR
8.000 16.000 0.747 Nom. Thickness

NOTES:
ALLOWABLE STRESSES AND DESIGN PROCEDURES FOR STONE STRENGTH USE AVERAGE TEST VALUES PER ASTM C99 "MODULUS OF RUPTURE"
AND ASTM C880 "FLEXURAL STRENGTH - MODIFIED" COMPARED TO SPECIFIED AND /OR INDUSTRY STANDARD SAFETY FACTORS.

DESIGN THICKNESS = "Nominal - Tolerance @ Thickness (e1)".


KERF GAGE = "kg" is defined as the nominal dimension for kerf location off stone face.
KERF THICKNESS = "kt" is defined as the dimension for kerf fabrication width.
KERF DEPTH = "kd" is defined as the dimension for kerf fabrication depth into edge of stone.
KERF ENGAGEMENT = "ke" is defined as the depth of kerf clip into the kerf depth.
KERF TOLERANCE = "e2" is defined as the dimension tolerance for kerf location off stone face.
KEFT CLIP LENGTH = "l" is the defined dimension of the clip at top of stone at 1/4 points of panel.

ALL DESIGN STRESSES AND DESIGN VALUES ACCOUNT FOR NOMINAL DIMENSIONS AND THE APPROPRIATE TOLERANCES.
ZARA - PRECISION JUN 09 2016 10
TYPICAL GRIDWORX SYSTEM

ZARA - PRECISION JUN 09 2016 11


Gridworx Fastener Loads – Fascia
Design Data:
(-WL) = 19.72 (psf)
(+WL) = 14.43 (psf)
Seismic = 33.047 (psf)
Stone Density = 152 (pcf)
Stone Thickness = 1.181 (in)
Thickness Tolerance = 0.125 (in)
Stone Height = 24 (in)
Stone Width = 60 (in)
Horizontal Fastener Spacing = 16 (in)
Fastener Bending = 1.313 (in)
Intermediate Anchorage = None

LOADING CONDITIONS: -WL + DL, AND DL ONLY


Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)
(lb) (lb) (lb) (lb) (in2) (psi)
STANDARD TOP J 57 NA 0 27 0.271 98
STANDARD INTERMEDIATE T 50 12 22 30 0.813 36
STANDARD STARTER J 71 NA 44 71 0.673 106
LOADING CONDITION: +WL + DL
Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)

(lb) (lb) (lb) (lb) (in2) (psi)


STANDARD TOP J 16 NA NA 19 0.460 42
STANDARD INTERMEDIATE T 9 0 22 55 0.813 68
STANDARD STARTER J 71 NA 44 109 0.673 163
Allowable fp = 350psi for 1/2" regular gypsum board

Maximum Tension = 71 lbs


Maximum Shear = 44 lbs

FASTENER CONDITIONS
Max Allowable T-31
Max Tension Allowable Allowable Max Bending Capacity
Shear Bending Stress Anchors
(lb) Tension (lb) Shear (lb) Stress (ksi) Check
(lb) (ksi) per row

#12-14 Dril-Flex (16ga metal) 71 130 44 474 58 69 N.A. O.K.

FILE: Fastener Loads(10-3-2014).xls


ZARA - PRECISION JUN 09 2016 12
Gridworx Fastener Loads – Cornice
Design Data:
(-WL) = 19.72 (psf)
(+WL) = 14.43 (psf)
Seismic = 145.514 (psf)
Stone Density = 152 (pcf)
Stone Thickness = 5.625 (in)
Thickness Tolerance = 0.125 (in)
Stone Height = 9 (in)
Stone Width = 60 (in)
Horizontal Fastener Spacing = 16 (in)
Fastener Bending = 1.313 (in)
Intermediate Anchorage = None

LOADING CONDITIONS: -WL + DL, AND DL ONLY


Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)
(lb) (lb) (lb) (lb) (in2) (psi)
EXTENDED INTERMEDIATE T 73 0 18 49 0.813 60
LOADING CONDITION: +WL + DL
Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)
2
(lb) (lb) (lb) (lb) (in ) (psi)
EXTENDED INTERMEDIATE T 33 0 18 58 0.813 72
Allowable fp = 350psi for 1/2" regular gypsum board

Maximum Tension = 73 lbs


Maximum Shear = 18 lbs

FASTENER CONDITIONS
Max Allowable T-31
Max Tension Allowable Allowable Max Bending Capacity
Shear Bending Stress Anchors
(lb) Tension (lb) Shear (lb) Stress (ksi) Check
(lb) (ksi) per row

#12-14 Dril-Flex (16ga metal) 73 130 18 474 24 69 N.A. O.K.

FILE: Fastener Loads(10-3-2014).xls


ZARA - PRECISION JUN 09 2016 13
Gridworx Fastener Loads – Soffit
Design Data:
(-WL+DL) = 36.26 (psf)
(+WL) = 14.43 (psf)
Seismic = 33.047 (psf)
Stone Density = 152 (pcf)
Stone Thickness = 1.181 (in)
Thickness Tolerance = 0.125 (in)
Stone Height = 16 (in)
Stone Width = 8 (in)
Horizontal Fastener Spacing = 8 (in)
Fastener Bending = 1.313 (in)
Intermediate Anchorage = None

LOADING CONDITIONS: -WL + DL, AND DL ONLY


Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)
2
(lb) (lb) (lb) (lb) (in ) (psi)
STANDARD TOP J 30 NA 0 14 0.271 51
STANDARD INTERMEDIATE T 24 8 10 14 0.813 17
STANDARD STARTER J 96 NA 21 33 0.673 49
LOADING CONDITION: +WL + DL
Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)
2
(lb) (lb) (lb) (lb) (in ) (psi)
STANDARD TOP J 5 NA NA 6 0.460 14
STANDARD INTERMEDIATE T 7 0 10 22 0.813 27
STANDARD STARTER J 33 NA 21 46 0.673 68
Allowable fp = 350psi for 1/2" regular gypsum board

Maximum Tension = 96 lbs


Maximum Shear = 21 lbs

FASTENER CONDITIONS
Max Allowable T-31
Max Tension Allowable Allowable Max Bending Capacity
Shear Bending Stress Anchors
(lb) Tension (lb) Shear (lb) Stress (ksi) Check
(lb) (ksi) per row

#12-14 Dril-Flex (16ga metal) 96 130 21 474 27 69 N.A. O.K.

FILE: Fastener Loads(10-3-2014).xls


ZARA - PRECISION JUN 09 2016 14
Gridworx Fastener Loads – Slim Starter with Fork Support
Design Data:
(-WL) = 19.72 (psf)
(+WL) = 14.43 (psf)
Seismic = 33.047 (psf)
Stone Density = 152 (pcf)
Stone Thickness = 1.181 (in)
Thickness Tolerance = 0.125 (in)
Stone Height = 7.875 (in)
Stone Width = 60 (in)
Horizontal Fastener Spacing = 16 (in)
Fastener Bending = 1.313 (in)
Intermediate Anchorage = None

LOADING CONDITIONS: -WL + DL, AND DL ONLY


Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)
2
(lb) (lb) (lb) (lb) (in ) (psi)
INTERIOR STARTER J 16 NA 14 15 0.542 28
LOADING CONDITION: +WL + DL
Tension (1) Tension (2) Shear Compression Bearing Area fP (C/A)

(lb) (lb) (lb) (lb) (in2) (psi)


INTERIOR STARTER J 15 NA 14 28 0.542 51
Allowable fp = 350psi for 1/2" regular gypsum board

Maximum Tension = 16 lbs


Maximum Shear = 14 lbs

FASTENER CONDITIONS
Max Allowable T-31
Max Tension Allowable Allowable Max Bending Capacity
Shear Bending Stress Anchors
(lb) Tension (lb) Shear (lb) Stress (ksi) Check
(lb) (ksi) per row

#12-14 Dril-Flex (16ga metal) 16 130 14 474 19 69 N.A. O.K.

FILE: Interior Fastener Loads(10-6-2015).xls


ZARA - PRECISION JUN 09 2016 15
ZARA - PRECISION JUN 09 2016 16
Intermediate T Anchor
System Depth (nom.)

t (nom.) 0.250"

0.500" # 12-14 x 2" DRIL-FLEX


STALGARD FINISH

kg kt
1/4" X 1/2" FOAM TAPE
PRE-APPLIED TO GRIDWORX INTERMEDIATE
CONTINUOUS STONE T ANCHOR
GRIDWORX L BRACKETS PREP EXTRUSION WITH
0.228" x 1" SLOT - 16" O.C.
NOM.
0.375"

# 12-14 x 2" DRIL-FLEX


GRIDWORX L BRACKET STALGARD FINISH
6" LONG
0.500"

LOW MODULUS SILICONE


FULL BEARING HI-IMPACT
APPLIED INTO KERF AT
RESISTANT PLASTIC SHIMS
ANCHOR LOCATIONS

WATERPROOFING MEMBRANE
AT FACE OF SHEATHING SPEC'D
AND PROVIDED BY OTHERS

HIGH GRADE SHEATHING


OVER METAL STUDS @ 16" O.C.

INTERMEDIATE T ANCHOR
3/8" JOINTS - STEEL FRAMING SCALE: FULL

ZARA - PRECISION JUN 09 2016 17


ZARA - PRECISION JUN 09 2016 18
Extended Int T Anchor

System Depth (nom.)

5.625" 0.250"

FULL BEARING HI-IMPACT


RESISTANT PLASTIC SHIMS

4.813 kt #12 x 2" DRIL-FLEX,


FINISH: STALGARD

GRIDWORX INTERMEDIATE
T ANCHOR
0.375"
NOM.

1/4" X 1/2" FOAM TAPE


PRE-APPLIED TO
Gridworx L Brackets

Gridworx L Bracket
6" LONG
WATERPROOFING MEMBRANE
(1) PER FT OF STONE WIDTH
AT FACE OF SHEATHING SPEC'D
(AT LEAST (2) PER PANEL)
AND PROVIDED BY OTHERS
LOW MODULUS SILICONE
APPLIED INTO KERF AT HIGH GRADE SHEATHING
ANCHOR LOCATIONS OVER METAL STUDS @ 16" O.C.

EXTENDED INT T ANCHOR


3/8" JOINTS - STEEL FRAMING SCALE: FULL

ZARA - PRECISION JUN 09 2016 19


HIGH GRADE SHEATHING
OVER METAL STUDS
@16" O.C.

GRIDWORX TYPE #31


1-1/4" ANCHORS.
EPOXIED IN 1/4" HOLES
DRILLED 45°.

LOW MODULUS SILICONE


APPLIED INTO T-31 SLOT
INSTALL AT 16" O.C. SPACING
CENTER LINE OF T-31 FASTENER
(REFER TO CUTTING TICKET)
1/4"
1.5" GRIDWORX STEEL
5/8"
FASTENER 16" O.C.
GRIDWORX SLIM STARTER ANCHOR

FULL BEARING HI-IMPACT


RESISTANT PLASTIC SHIMS
FIELD VERIFY
(AS NEEDED, 5/8" MAX)

B.O.STONE
160'-9 1/2"

LOW MODULUS SILICONE


WITH OPEN CELL
BACKER ROD

EXTERIOR STONE HANGING SYSTEM

SECTION DETAIL
STEEL FRAMING

ZARA - PRECISION JUN 09 2016 20


ZARA - PRECISION JUN 09 2016 21
ASHRAE SYSTEM

ZARA - PRECISION JUN 09 2016 22


ZARA - PRECISION JUN 09 2016 23
ZARA BROADWAY PLAZA
Cbeam R5
Architectural Wall Systems
6/8/2016 14:15 File: Horiz Intermediate T(16)

HORIZONTAL INTERMEDIATE T
By: SJM
Z-CHANNEL
STONE COURSE HEIGHT = 22"

5
Deflection Results
Max. Deflection = -0.0009" L/17430 (Span 1, @ 7.04")

1'-4"
Stress Results
Span M(in-lb) fb-m(ksi)
1 @ 6.29" = 70 0.554
4 @ 0.00" = -97 0.769 Z-CHANNEL

4
Member Information
Span Length(in) I(in^4) S(in^3) E(psi)

1'-4"
1 16.000 0.163 0.126 1.0e+7
2 16.000 0.163 0.126 1.0e+7
3 16.000 0.163 0.126 1.0e+7
4 16.000 0.163 0.126 1.0e+7

Z-CHANNEL

3
Distributed Load Information
Span W1(#/in) W2(#/in) X1(in) X2(in)
1 3.534 3.534 0.000 16.000
2 3.534 3.534 0.000 16.000

1'-4"
3 3.534 3.534 0.000 16.000
4 3.534 3.534 0.000 16.000

Support Reactions
Z-CHANNEL
Joint Pounds
2

1 22
2 65
3 53
4 65
1'-4"

5 22
WL = 22" x 33.047PSF x 0.7 = 3.534#/IN
3.534 lb/in

For questions on Cbeam, a Windows-based program, contact: Z-CHANNEL


1

MCALSOFT LLC. www.mcalsoftware.com


Ph (512) 270-6869
Email: software@mcalsoftware.com

1
Driven by Cbeam © R5
ZARA - PRECISION JUN 09 2016 24
ZARA - PRECISION JUN 09 2016 25
ZARA BROADWAY PLAZA
Cbeam R5
Architectural Wall Systems
6/8/2016 14:26 File: VERTICAL Z - 1IN DEEP(16in)

VERTICAL Z - 1" DEEP


By: SJM
COURSE HEIGHT = 22" CL DISCRETE

6
Deflection Results
Max. Deflection = -0.0213" L/1129 (Span 5, @ 12.24")
Cant. Deflection = -0.0359" 2L/334 (Span 1, @ 0.00")

2'-0"
DEFLECTION AND STRESS OK BY INSPECTION 65 #

Stress Results
Span M(in-lb) fb-m(ksi)
CL DISCRETE
1 @ 6.00" = -390 4.643

5
5 @ 10.00" = 236 2.807

Member Information

2'-0"
65 #
Span Length(in) I(in^4) S(in^3) E(psi)
1 6.000 0.043 0.084 1.0e+7
2 24.000 0.043 0.084 1.0e+7
3 24.000 0.043 0.084 1.0e+7
CL DISCRETE
4 24.000 0.043 0.084 1.0e+7

4
5 24.000 0.043 0.084 1.0e+7

Point Load Information 65 #

2'-0"
Span P(#) X(in)
1 65.000 0.000
2 65.000 16.000
3 65.000 14.000
4 65.000 12.000 CL DISCRETE
3

5 65.000 10.000

65 #
Joints Free to Displace
2'-0"

Free Joints - 1

Support Reactions
Joint Pounds CL DISCRETE
2

6"

2 97
3 57 65 #
1

4 72
5 82
6 17

1
Driven by Cbeam © R5
ZARA - PRECISION JUN 09 2016 26
FASTENERS AT Z-CHANNEL TO DISCRETE CLIP
DESIGN OF TAPPING FASTENERS SAE-J429/GRADE 5, OR ASTM-A449
Design Data: Shear, V= 44 (lb) Material at Fastener Head 6005-T5

Tension, T= 102 (lb) Hole or Slot Hole


Bending Eccentricity, e= 0 (in) Material Thickness (in) = 0.09
Quantity= 2 Flat Head (Y or N) N
Duration of Load Factor = 1 Material Tapped Into 6005-T5
Two Materials Flush? N Hole or Slot Hole
Dws = 0.5 (in) Material Thickness = 0.125

Interaction = (fV/FV)2 + (fT/FT)2  1 Capacity Check = For Each: T < Ta, V < Va

MATERIAL SPECIFICATIONS - FASTENER PROPERTIES


MINIMUM ULTIMATE TENSILE STRENGTH (Fu) = 120,000 psi
MINIMUM TENSILE YIELD STRENGTH (Fy) = 92,000 psi
K A(R) FASTENER BENDING CHECK
D BASIC THREAD Fb (0.75xFyxDf) (KSI) = 69
FASTENER NOMINAL MINOR ROOT ALLOW. ALLOW. *FASTENER
SIZE DIAMETER DIAMETER AREA TENSION SHEAR INTERACTION SX MOMENT fb
2 3 (M/SX)
N (IN.) (IN.) (IN. ) (LB.) (LB.) < DF PI*D /32 (V*e) / 2
#6- 20 0.1380 0.0997 0.0078 375 216 0.029 0.0003 0 0.00
#8- 18 0.1640 0.1257 0.0124 596 344 0.011 0.0004 0 0.00
#10- 16 0.1900 0.1389 0.0152 727 420 0.008 0.0007 0 0.00
#12- 14 0.2160 0.1649 0.0214 1025 592 0.004 0.0010 0 0.00 
#14- 14 0.2420 0.1880 0.0278 1332 769 0.002 0.0014 0 0.00
1/4"- 14 0.2500 0.1887 0.0280 1342 775 0.002 0.0015 0 0.00
1/4"- 20 0.2500 0.1887 0.0280 1342 775 0.002 0.0015 0 0.00
5/16"- 18 0.3125 0.2443 0.0469 2250 1299 0.001 0.0030 0 0.00
3/8"- 12 0.3750 0.2983 0.0699 3355 1937 0.000 0.0052 0 0.00

MATERIAL AT FASTENER HEAD MATERIAL TAPPED INTO


FASTENER ALLOW ALLOW CAPACITY FASTENER ALLOW. ALLOW. ALLOW. CAPACITY
SIZE PULL-OVER BEARING CHECK SIZE PULL-OUT BEARING TILTING CHECK
Ta (LB.) Va (LB.) < DF Ta (LB.) Va (LB.) Va (LB.) < DF
#6-20 686 315 O.K. #6-20 287 437 873 O.K.
#8-18 686 374 O.K. #8-18 317 519 952 O.K.
#10-16 686 433 O.K. #10-16 333 602 1025 O.K.
#12-14 686 492 O.K.  #12-14 378 684 1093 O.K. 
#14-14 686 552 O.K. #14-14 424 766 1157 O.K.
1/4"-14 686 570 O.K. 1/4"-14 438 792 1176 O.K.
1/4"-20 686 570 O.K. 1/4"-20 438 792 1176 O.K.
5/16"-18 686 713 O.K. 5/16"-18 605 990 1314 O.K.
3/8"-12 686 855 O.K. 3/8"-12 656 1188 1440 O.K.
NOTES:
ALLOWABLE STRESSES AND DESIGN PROCEDURES FOR TAPPING FASTENERS ARE PER ADM 2010 AND AISC 14TH,
RESPECTIVELY PER SUBSTRATE

A(R) = 0.7854*(K)2
ALLOW. TENSION = 0.4*Fu*A(R) (AAMA TIR-A9-91 2000 ADDENDUM PG 34)
ALLOW. PULL-OUT = Ks*D*t2*Fty2/3 (TYPICAL) (REF. SECTION J.5.5.1.1 ADM-10)
ALLOW. PULL-OVER = C*t1*Ftu1(Dws-D)/3 (TYPICAL) (REF SECTION J.5.5.2 ADM-10)
ALLOW. SHEAR = 0.4*Fu*A(R) / (SQRT(3)) (AAMA TIR-A9-91 2000 ADDENDUM PG 34)
ALLOW. TILTING = 4.2*(t2^3*d)^(1/2)*Ftu2/3 (REF SECTION J.5.6 EQ J.5-13 ADM-10)
ALLOW. BEARING/STEEL = 1.2*Fu*D*t (Fu = 58,000 psi) (J3-6a AISC) (HOLE)
ALLOW. BEARING/STEEL = 1.0*Fu*D*t (Fu = 58,000 psi) (J3-6c AISC) (SLOT)
ALLOW. BEARING/ALUM. = 2*Ftu*D*t/3 (REF. SECTION J.5.6.1 ADM -10)
Ftu for each Alum. Alloy referenced from ADM-10
*INTERACTION = (V / (ALLOW. SHEAR x QUANTITY) )^2 + (T / (ALLOW. TENSION x QUANTITY) )^2

DL = (1.181” + 0.125”) x 24” x 16” x 152PCF = 44#


DL(TENSION) = 44# x (1.333” + 0.625” + 1.0”) / 24 = 5#
WL + DL(TENSION) = 97# + 5# = 102# (REF: VERTICAL Z - 1” DEEP CBEAM)

FILE: Tapping Fasteners - ADM10 - AISC14.xls


ZARA - PRECISION JUN 09 2016 27
FASTENERS AT DISCRETE CLIP TO STUDS
DESIGN OF TAPPING FASTENERS SAE-J429/GRADE 5, OR ASTM-A449
Design Data: Shear, V= 44 (lb) Material at Fastener Head 6005-T5

Tension, T= 108 (lb) Hole or Slot Hole


Bending Eccentricity, e= 0.625 (in) Material Thickness (in) = 0.125
Quantity= 2 Flat Head (Y or N) N
Duration of Load Factor = 1 Material Tapped Into A-33
Two Materials Flush? N Hole or Slot Hole
Dws = 0.5 (in) Material Thickness = 0.054

Interaction = (fV/FV)2 + (fT/FT)2  1 Capacity Check = For Each: T < Ta, V < Va

MATERIAL SPECIFICATIONS - FASTENER PROPERTIES


MINIMUM ULTIMATE TENSILE STRENGTH (Fu) = 120,000 psi
MINIMUM TENSILE YIELD STRENGTH (Fy) = 92,000 psi
K A(R) FASTENER BENDING CHECK
D BASIC THREAD Fb (0.75xFyxDf) (KSI) = 69
FASTENER NOMINAL MINOR ROOT ALLOW. ALLOW. *FASTENER
SIZE DIAMETER DIAMETER AREA TENSION SHEAR INTERACTION SX MOMENT fb

N (IN.) (IN.) (IN.2) (LB.) (LB.) < DF PI*D3/32 (V*e) / 2 (M/SX)


#6- 20 0.1380 0.0997 0.0078 375 216 0.031 0.0003 14 26.65
#8- 18 0.1640 0.1257 0.0124 596 344 0.012 0.0004 14 15.88
#10- 16 0.1900 0.1389 0.0152 727 420 0.008 0.0007 14 10.21
#12- 14 0.2160 0.1649 0.0214 1025 592 0.004 0.0010 14 6.95 
#14- 14 0.2420 0.1880 0.0278 1332 769 0.002 0.0014 14 4.94
1/4"- 14 0.2500 0.1887 0.0280 1342 775 0.002 0.0015 14 4.48
1/4"- 20 0.2500 0.1887 0.0280 1342 775 0.002 0.0015 14 4.48
5/16"- 18 0.3125 0.2443 0.0469 2250 1299 0.001 0.0030 14 2.29
3/8"- 12 0.3750 0.2983 0.0699 3355 1937 0.000 0.0052 14 1.33

MATERIAL AT FASTENER HEAD MATERIAL TAPPED INTO


FASTENER ALLOW ALLOW CAPACITY FASTENER ALLOW. ALLOW. ALLOW. CAPACITY
SIZE PULL-OVER BEARING CHECK SIZE PULL-OUT BEARING TILTING CHECK
Ta (LB.) Va (LB.) < DF Ta (LB.) Va (LB.) Va (LB.) < DF
#6-20 1039 437 O.K. #6-20 83 519 379 O.K.
#8-18 1039 519 O.K. #8-18 98 616 413 O.K.
#10-16 1039 602 O.K. #10-16 114 714 444 O.K.
#12-14 1039 684 O.K.  #12-14 130 812 474 O.K. 
#14-14 1039 766 O.K. #14-14 145 910 501 O.K.
1/4"-14 1039 792 O.K. 1/4"-14 150 940 509 O.K.
1/4"-20 1039 792 O.K. 1/4"-20 150 940 509 O.K.
5/16"-18 1039 990 O.K. 5/16"-18 187 1175 570 O.K.
3/8"-12 1039 1188 O.K. 3/8"-12 225 1409 624 O.K.
NOTES:
ALLOWABLE STRESSES AND DESIGN PROCEDURES FOR TAPPING FASTENERS ARE PER ADM 2010 AND AISC 14TH,
RESPECTIVELY PER SUBSTRATE

A(R) = 0.7854*(K)2
ALLOW. TENSION = 0.4*Fu*A(R) (AAMA TIR-A9-91 2000 ADDENDUM PG 34)
ALLOW. PULL-OUT = Ks*D*t2*Fty2/3 (TYPICAL) (REF. SECTION J.5.5.1.1 ADM-10)
ALLOW. PULL-OVER = C*t1*Ftu1(Dws-D)/3 (TYPICAL) (REF SECTION J.5.5.2 ADM-10)
ALLOW. SHEAR = 0.4*Fu*A(R) / (SQRT(3)) (AAMA TIR-A9-91 2000 ADDENDUM PG 34)
ALLOW. TILTING = 4.2*(t2^3*d)^(1/2)*Ftu2/3 (REF SECTION J.5.6 EQ J.5-13 ADM-10)
ALLOW. BEARING/STEEL = 1.2*Fu*D*t (Fu = 58,000 psi) (J3-6a AISC) (HOLE)
ALLOW. BEARING/STEEL = 1.0*Fu*D*t (Fu = 58,000 psi) (J3-6c AISC) (SLOT)
ALLOW. BEARING/ALUM. = 2*Ftu*D*t/3 (REF. SECTION J.5.6.1 ADM -10)
Ftu for each Alum. Alloy referenced from ADM-10
*INTERACTION = (V / (ALLOW. SHEAR x QUANTITY) )^2 + (T / (ALLOW. TENSION x QUANTITY) )^2

DL = (1.181” + 0.125”) x 24” x 16” x 152PCF = 44#


DL(TENSION) = 44# x (1.333” + 0.625” + 1.0” + 3.25”) / 24 = 11#
WL + DL(TENSION) = 97# + 11# = 108# (REF: VERTICAL Z - 1” DEEP CBEAM)

FILE: Tapping Fasteners - ADM10 - AISC14.xls


ZARA - PRECISION JUN 09 2016 28
Starter J Anchor
Standoff (nom.)

0.250" (+0.375"/- 0.250" Tol.)


t (nom.)

0.090" THK. ALUM. " Z " CLIP


CONTINUOUS
6005 - T5

1/8" THK. ALUM. CLIP


4" LONG
6005 - T5

#12-14 x 1" HWH


DRIL-FLEX

#12-14 x 2" HWH


DRIL-FLEX

#12-14 x 2" HWH


DRIL-FLEX

LOW MODULUS SILICONE


kg kt
APPLIED INTO KERF AT
ANCHOR LOCATIONS

GRIDWORX STARTER
J ANCHOR
0.375"
MIN

SILICONE COMPATIBLE
WEEP BAFFLE 30 DPI
24" O.C. BASE COURSE

STARTER J ANCHOR
SUBSTRATE - METAL STUD SCALE: FULL

ZARA - PRECISION JUN 09 2016 29


ZARA - PRECISION JUN 09 2016 30
Top J Anchor

Standoff (nom.)

#12-14 x 2" HWH


0.250" (+0.375"/- 0.250" Tol.) DRIL-FLEX
t (nom.)
0.375"
MIN

GRIDWORX L BRACKET
W/ 1/4"x1/2" FOAM TAPE

kg kt
#12-14 x 2" HWH
DRIL-FLEX

GRIDWORX TOP
J ANCHOR

LOW MODULUS SILICONE


APPLIED INTO KERF AT
ANCHOR LOCATIONS

1/8" THK. ALUM. CLIP


4" LONG 6005 - T5

#12-14 x 1" HWH


DRIL-FLEX

0.090" THK. ALUM. " Z " CLIP


CONTINUOUS
6005 - T5

TOP J ANCHOR
SUBSTRATE - METAL STUD SCALE: FULL

ZARA - PRECISION JUN 09 2016 31


MISCELLANEOUS REFERENCE

ZARA - PRECISION JUN 09 2016 32


ZARA - PRECISION JUN 09 2016 33
Fastener Loads: (+WL + DL)

0.283" 0.093" 0.250"


0.287"

COMPRESSION = 0.287" x WL / (2/3 x 0.850")


0.850"

. = 0.507 x WL
0.500"
0.167"

BEARING AREA = 1/3 x 0.850" x 1.625" = 0.460 in²

fp = C/A = 0.500 x WL / A

1.333"

TENSION = DL x 1.333" / 2.0"


0.500"

= 0.670 x DL
DEADLOAD ONLY = CRITICAL TENSION

SHEAR = DL / 2
1.337"

COMPRESSION = 1.337" x WL / 2.0" + 1.333" x DL / 2.0"


2.000"

0.670 x WL + 0.670 x DL

BEARING AREA = 0.500" x 1.625" = 0.813 in²


0.663"

fp = C/A = 0.670 X ( WL + DL ) / A
0.500"

1.333" TENSION = 1.333" x DL / (2/3 x 1.243")


= 1.609 x DL
.
0.500"

SHEAR = DL
0.830"

0.414"

COMPRESSION = WL + 1.609 x DL
1.243"

BEARING AREA = 1/3 x 1.243" x 1.625" = 0.673 in²

fp = C/A = ( WL + 1.609 x DL ) / A

ZARA - PRECISION JUN 09 2016 34


ZARA - PRECISION JUN 09 2016 35
Fastener Loads: (-WL + DL) & (DL ONLY)

0.093" 0.250" TENSION = WL + WL x 0.287" / (2/3 x 0.500")


. = 1. 860 x WL
0.288"
0.850"

COMPRESSION = 1.860 x WL - WL
. = 0.860 x WL
0.500"
0.167"

BEARING AREA = 1/3 x 0.500" x 1.625" = 0.271 in²

fp = C/A = 0.860 x WL / A

0.700"
-WL & DL:
TENSION (1) = WL x 0.668" / 1.75" + DL x 0.7" / 1.75"
0.500"

. = 0.393 x WL + 0.4 x DL

TENSION (2) = WL x 1.062" / 1.75" - DL x 0.7" / 1.75"


. = 0.607 x WL - 0.4 x DL
1.062"
1.750"

SHEAR = DL / 2
0.688"

DL ONLY:
COMPRESSION = DL x 0.7" / 1.75" = 0.4 x DL
0.500"

BEARING AREA = 0.500" x 1.625" = 0.813 in²

fp = C/A = 0.4 x DL /A

0.700"
-WL & DL:
DEADLOAD ONLY IS CRITICAL FOR
0.500"

DESIGN WINDLOADS < 50 PSF


0.595"

TENSION = DL x 0.7" / (2/3 x 1.0")


0.333"

. = 1.05 x DL
1.000"

SHEAR = DL

COMPRESSION = 1.05 x DL
.
BEARING AREA = 1/3 x 1.0" x 1.625" = 0.542 in²

fp = C/A = 1.05 x DL / A

ZARA - PRECISION JUN 09 2016 36


Fastener Loads: (+WL + DL)

0.283"
0.093" 0.250"
0.288"

COMPRESSION = 0.287" x WL / (2/3 x 0.850")


0.850"

. = 0.507 x WL
0.500"
0.167"

BEARING AREA = 1/3 x 0.850" x 1.625" = 0.460 in²

fp = C/A = 0.500 x WL / A

0.700"
TENSION = DL x 0.7" / 1.75"
0.500"

= 0.4 x DL
DEADLOAD ONLY = CRITICAL TENSION

SHEAR = DL / 2
1.062"

COMPRESSION = 1.062" x WL / 1.75" + 0.7" x DL / 1.75"


0.607 x WL + 0.4 x DL
1.750"

BEARING AREA = 0.500" x 1.625" = 0.813 in²


0.688"

fp = C/A = (0.607 x WL + 0.4 x DL ) / A


0.500"

0.700" TENSION = 0.7" x DL / (2/3 x 1.0")


= 1.05 x DL
.
0.500"

SHEAR = DL
0.595"

COMPRESSION = WL + 1.05 x DL
0.333"
1.000"

BEARING AREA = 1/3 x 1.0" x 1.625" = 0.542 in²

fp = C/A = ( WL + 1.05 x DL ) / A

ZARA - PRECISION JUN 09 2016 37


ZARA - PRECISION JUN 09 2016 38

Vous aimerez peut-être aussi