TUI reports surface integrals in SI units only (Solution 845)

ƒ The values of Surface Integrals and Flux Reports are always reported in SI units when
accessed through the Text User Interface (TUI) while they are reported in the user-
specified units in the Graphic User Interface (GUI)
ƒ Workaround: Use a function which will convert the value from SI units to the user specified
units for the desired variable

kg/s

lbm/s

ƒ In the example above, the mass-flow rate value is 1.3142 kg/s but the user is interested in
lbm/s, which is the user specified unit in the GUI. The following function can be used:

(to-user-units 1.3142 'mass-flow)

ƒ In order to use this function for other variables, “mass-flow” should be replaced by
the desired variable (e.g. temperature, velocity, length, etc)